Loading...
HomeMy WebLinkAbout1246-1oaolr r� R/ VERS/DE j Q 0 Q 3 W W W Q � Q W Q J AVENUE 1 /1 1 f% A A I 1 W Q Q U.S. HWY. /O SLOVER AVENUE W � Z Q v ✓URUPA AVENUE J� PROJECT SITE VICINITY MAP NO SCALE -r* r1% ►1n 1A A A I /1 T ri L1^ 1^ A A I '? SCALE: I"= IOOI T P11 d 1 n 1 e% A A I A SEWER IMPROVEMENT PLANS TRACT N0. 12441 I TRACT NO,, 12441 - 2 TRACT N 0. 12441- 3 TRACT N 0. 12441 - 4 TRACT N 0. 12441 FONTANA, CALIFORNIA L Q � TD k1n i.>aai PRIVATE ENGINEERS NOTICE TO CONTRACTOR 1. ALL UNDERGROUND UTILITIES OR STRUCTURES REPORTED BY THE OWNER OR OTHERS, AND THOSE SHOWN ON THE RECORDS EXAMINED ARE SHOWN WITH THEIR APPROXIMATE LOCATION AND EXTENT. 2. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE NATURE OF EX.`STING GROUND AND/OR -THE FINISHED GRADE IN THE VICINITY OF THE PROPOSED CONSTRUCTION AREA IMMEDIATELY PRIOR TO CONSTRUCTION. ` 3. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILTIES OR STRUCTURES FOUND AT THE SITE. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE OWNERS OF THE UTILITIES OR STRUCTURES CONCERNED BEFORE STARTING WORK. 4. THE CONTRACTOR SHALL UNCOVER ALL UTILITIES THAT HE MAY BE JOINING, CROSSING OR PARALLELING PRIOR TO ANY CONSTRUCTION TO VERIFY BOTH HORIZONTAL AND VERTICAL LOCATIONS. ANY CONFLICT OR DISCREPANCY SHALL BE BROUGHT TO THE ENGINEER'S ATTENTION PRIOR TO CONSTRUCTION, OTHERWISE THE CONTRACTOR ACCEPTS FULL RESPONSIBILITY FOR ANY COSTS OF RELOCATION OR ADDITIONAL COSTS OF CONSTRUCTION. CONTRUCTION NOTES AND QUANTITY ESTIMATES 0: U) nl LAJ <I b c I� i t c c. l Q 11 1 --- CITY OF FONTANAQZ U4 - M V.1 J y 1 v) ) 8353 SIERRA AVENUE ~ N ( I Op Q NUMBER ITEM QUANTITY UNIT FONTANA CALIFORNIA 92335 ' 17 1 � 18 I � 18 I � 18 I � � 18 TELEPHONE 14 823-3411 1_ I C7 ) --- --- W-- 'SO. CALIF. GAS COMPANY - DISTRIBUTION FACILITIES W--4- _ �'s'- 1� INSTALL STANDARD 48" PRE -CAST MANHOLES PER CITY 570 4TH STREET, P.O. BOX •6226 1 ' s •- WOODLAND .. T S r �-- DR/VE S --Q OF FONTANA STANDARD DETAIL 112 17 EA. SAN BERNARDINO, CALIFORNIA 92408 ` > S E E S H E E T 3 S E E SH E E T 4 O ADJUST MANHOLE COVERS TO FINAL GRADES PER CITY OF TELEPHONE (714) 884-9411 OR (800) 422-4133 S0. GALIF. GAS COMPANY = TRANSMISSION DEPARTMENT FONTANA STANDARD DETAIL 109 ( SEE NOTE 13 ) 17 EA. E-- 2191 BIRCH STREET Q 22 21 20 19 18 24 23 22 21 20 19 23 22 21 20 19 24 23 22 21 20 19 23 22 21 20 19 BREA, CALIFORNIA 92621 �-•� Q 1 O CONSTRUCT STANDARD 8" TERMINAL CLEANOUT PER CITY TELEPHONE (714) 529-2889OR (800) 422-4133 I I SOUTHERN CALIFORNIA EDISON COMPANY Z Z OF FONTANA STANDARD DETAIL 128 (SEE NOTE 13 ) 1 EA. -- -- - -- •-- •- LLJ INSTALL 8" EXTRA STRENGTH VITRIFIED CLAY PIPE 1351. E. FRANCIS AVENUE, P.O. BOX 513 (�j PER CITY OF FONTANA STANDARDS AND SPECIFICATIONS 4,4G2 L.F. ONTARIO, CALIFORNIA 91761 W I I TELEPHONE (714) 947-2996 - UNDERGROUND POWER li I �W W O5 INSTALL 8" WATER TIGHT PLUGS WITH TIGHTENING (714) 875-5100 _ TRANSMISSIONS I Z _j BANDS 5 EA. (213) 637-1233 PIPELINES, OR o TENTATIVE TRACT N0. _ 12354 (800) 422-4133 J W s - s s 6O INSTALL 10" EXTRA STRENGTH VITRIFIED CLAY PIPE 'GENERAL TELEPHONE COMPANY _ 0 PER CITY OF FONTANA STANDARDS AND SPECIFICATIONS 118 L.F. 245 N. MOUNTAIN VIEW AVENUE POMONA, CALIFORINA 91766 �- INSTALL 411 WATER TIGHT PLUGS WITH TIGHTENING Q 7 TELEPHONE (213) 357-2257 OR (800) 422-4133 S E E SHEET 2 Ia O BANDS 21 EA. :SAN BERN. COUNTY FLOOD CONTROL DISTRICT ui W 825 EAST THIRD STREET I Q �� INSTALL 4" WYE PER CITY OF FONTANA STANDARDS AND SAN.BERNARDINO, CALIFORNIA 92408 SPECIFICATIONS 21 EA. TELEPHONE (714) 383-1665COMPANY W PACIFIC TELEPHONE & TELEGRAP I = 1 O9 INSTALL 4" SEWER LATERAL PER CITY OF FONTANA 3073 ADAMS STREET STANDARD DETAIL 125 116 EA. RIVERSIDE, CALIFORNIA 92504 1 Z '�':f;;TELEPHONE (714) 359-2585 OR (800) 422-4133 Ix SELECTED NA711125 �`r �, N \'�;.•�>' :,; Y, SELECTS 0 NAT/YE ,BEDD/NO COM.�'ACTED 70-30% COA4PACrE-0 /000% 7-0 TYPICAL BEDDING FOR 8" VCP 10' OR .DEEPER_ TYPICAL BEDDING' FOR 8VICP NO SCALE LESS THAN 10' DEEP NO SCALE GENERAL NOTES 1. THE CONSTRUCTION OF ALL PUBLIC IMPROVEMENTS SHALL CONFORM TO THESE PLANS AND TO THE REQUIREMENTS OF THE CITY STANDARD SPECIFICATIONS, PUBLIC WORKS DEPARTMENT, CITY.OF FONTANA. REFER TO DEFINITIONS AND TERMS IN CITY STANDARD SPECIFICATIONS. 2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM FONTANA PUBLIC WORKS DEPARTMENT PRIOR TO START OF ANY WORK 'WITHIN THE CITY LIMITS. 3. STATIONING REFERS TO THE CENTERLINES OF STREET EXCEPT WHERE OTHERWISE l NOTED. 4. ALL UNDERGROUND WORK SHALL BE COMPLETED PRIOR TO PAVING OF STREETS. 5, EXISTING UNDERGROUND UTILITIES ARE AS PER AVAILABLE RECORDS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE ACTUAL LOCATION AND ELEVATION IN THE FIELD. 6. THE WALL'S AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE EFFECTIVELY GUARDED BY A SHORING SYSTEM, SLOPING OF THE GROUND OR OTHER EQUIVALENT MEANS. TRENCHES LESS THAN FIVE (5) FEET IN DEPTH SHALL ALSO BE GUARDED WHEN EXAMINATION INDICATES HAZARDOUS GROUND MOVEMENT MAY BE EXPECTED. 7. THE CONTRACTOR(S) SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK AS DESCRIBED IN NOTE 6 ABOVE FROM CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. SEE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION SECTION 306-1.1.6. 8 AI 1 MAAILJ/ll E FRAMES AND DOVE _S SHALL BE !`ONSTRUGTrr) BEbeW FT TS nnAr�r . tGSC-J` 1 J 1 1 1_ V SRA Y1 V L BY SEWER /l A 1 T n A /` T !1 1'f AND M SHALL LI %tl 1 pRAISED 1ATCCD TO GRADE '•nA Dr BY PAYING AYTNn _ 6 /'1 \ I T n A 6 T /l n -,-TER eet+P�ETIGN eF PAYING. 9. REFER TO CITY OF FONTANA, UNDERGROUND UTILITY LOCATION STANDARD DETAIL 129. 10. ADEQUATE STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORKS TO THE PLAN GRADES. 11. AS BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE CITY OF FONTANA. 12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE RESETTING OF ANY SURVEY MONUMENTS, ;STREET CENTERLINE MONUMENTS, OR BENCH MARKS WHICH ARE DISTURBED DURING CONSTRUCTION WHETHER THEY ARE SHOWN ON THE PLANS OR NOT, 13. ALL MANHOLE FRAMES AND COVERS SHALL BE CONSTRUCTED 6" BELOW FINISHED GRADE BY SEWER CONTRACTOR AND SHALL BE RAISED TO GRADE) BY PAVING CONTRACTOR AFTER COMPLETION OF PAVING. 14, ALL 4" HOUSE SEWER LATERALS SHALL BE INSTALLED ON A 2% MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER. 15. TERMINATE ALL 4" HOUSE SEWER LATERALS AT THE PROPERTY LINE WITH A PLUG. 16. CHIS. X SHALL BE PLACED ON THE CURB OVER LOCATIONS OF SEWER LATERALS BY THE -SEWER CONTRACTOR. 17. IT SHALL BE THE CONRACTOR'S RESPONSIBILITY TO VERIFY THE HORIZONTAL LOCATION AND VERTICAL ELEVATIONS OF ALL UTILITY CROSSINGS FOR ALL UTILITIES CONSTRUCTED PRIOR TO THE SEWER. ANY DISCREPANCIES SHALL BE MADE IN WRITING TO THE OWNER PRIOR TO CONSTRUCTION. 18. CONTRACTOR SHALL NOTIFY CHINO BASIN MUNICIPAL WATER DISTRICT (CBMWD), TELEPHONE NO. (714) 987-1712, AT LEAST 24 HOURS PRIOR TO STARTING CONSTRUCTION. 19. THE CONTRACTOR(S) SHALL COORDINATE CONSTRUCTION WITH ALL UTILITIES AND OTHER IMPROVEMENTS INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRICAL, LIGHTING, TELEVISION CABLE, LANDSCAPING, LANDSCAPING IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAINAGE, FLOOD CONTROL SYSTEMS, ETC. 48 -HOURS PRIOR TO EXCAVATION NEAR THEIR FACILITIES, NOTIFY: .11 a