HomeMy WebLinkAbout1135-1GENERAL NOTES 1. THE CONSTRUCTION OF ALL PUBLIC IMPROVEMENTS SHALL CONFORM .TO THESE PLANS AND TO THE REQUIREMENTS OF THE CITY STANDARD SPECIFICATIONS, PUBLIC WORKS DEPARTMENT, CITY OF FONTANA. 2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM FONTANA PUBLIC WORKS DEPARTMENT PRIOR TO START OF ANY WORK WITHIN THE CITY LIMITS. 3. STATIONING REFERS TO THE CENTERLINES OF -STREET EXCEPT WHERE OTHERWISE NOTED. 4. ALL UNDERGROUND WORK SHALL BE COMPLETED PRIOR 'TO PAVING OF STREETS. 5. EXISTING UNDERGROUND UTILITIES ARE AS.PER AVAILABLE RECORDS.. THE CONTRACTOR SHALL BE -RESPONSIBLE FOR VERIFYING THE ACTUAL LOCATION -AND ELEVATION'I-N THE FIELD. 6.. THE WALLS -AND FACES OF ALL_EXCAVATIONS GREATER -THAN FIVE,(5) FEET' IN DEPTH SHALL BE EFFECTIVELY GUARDED•'BY.A SHORING.SYSTEM,SLOPING :OF THE GROUND:OR OTHER EQUIVALENT MEANS. TRENCHES LESS THAN FIVE (5) FEET IN DEPTH SHALL ALSO BE GUARDED WHEN EXAMINATION INDICATES HAZARDOUS GROUND MOVEMENT MAY. -BE EXPECTED. 7. THE CONTRACTOR(S) SHALL OBTAIN. A' PERMIT TO PERFORM EXCAVATION OR"TRENCH WORK AS DESCRIBED IN:NOTE 6 ABOVE FROM. CALIFORNIA STATE DIVISION.OF INDUSTRIAL SAFETY. SEE.'STANDARD.SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION SECTION 306-1.1.6. .8. REFER TO CITY OF FONTANA UNDERGROUND, UTILITY LOCATION STANDARD DETAIL 129. 9. THE CONTRACTOR(S) SHALL COORDINATE CONSTRUCTION.WITH.ALL UTILITIES AND OTHER IMPROVEMENTS INCLUDING; BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRICAL, LIGHTING, TELEVISION CABLE, LANDSCAPING, LANDSCAPING IRRIGATION,. DOMESTIC WATER, RECLAIMED WATER., SEWER, STORM DRAINAGE., FLOOD CONTROL SYSTEMS, ETC. 10. ADEQUATE STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE' CONTRACTOR TO CONSTRUCT THE WORKS TO -THE PLAN GRADES. 11. AS—BUILT PLANS SHALL BE PROVIDED..BY THE CONTRACTOR. TO THE CITY OF FONTANA. 12. ALL MANHOLE FRAMES AND COVERS. -SHALL BE CONSTRUCTED 6" BELOW FINISHED GRADE BY SEWER CONTRACTOR*..AND SHALL BE RAISED.TO-GRADE BY PAVING CONTRACTOR'AFTER COMPLETION OF PAVING. 13. ALL 4" HOUSE SEWER LATERALS SHALL BE INSTALLED ON A.2/ MINIMUM GRADE UNLESS. OTHERWISE APPROVE D'BY THE CITY ENGINEER. 14. TERMINATE ALL 4" HOUSE -SEWER LATERALS.AT THE PROPERTY LINE WITH A PLUG 15. CHIS. X SHALL BE PLACED ON THE'CURB OVER LOCATIONS OF SEWER LATERALS -BY THE' SEWER CONTRACTOR. `.16. -IT SHALT_ BE THE CONTRACTORS RESPONSIR.ILITY TO VERIFY THE HORIZONTAL LOCATION AND VERTICAL CAL ELEVATIONS OF ALL UTILITY CROSSING] FOR ALL UTILITIES CONSTRUCTED•PRIOR TO HE ScWER CONSTRUCTION. ANY DISCREPANCIES SHALL BE MADE IN WRITING TO THE OWNER PRIOR TO CONSTRUCTION. 17. CONTRACTOR SHALL NOTIFY CHINO BASIN MUNICIPAL WATER DISTRICT (CBMWD), TELEPHONE NO. (7.14) 987-1712, AT LEAST 24 HOURS PRIOR TO STARTING CONSTRUCTION— PRIVATE ENGINEER'S NOTICE TO CONTRACTOR: 1. ALL UNDERGROUND UTILITIES OR STRUCTURES REPORTED BY THE OWNER OR OTHERS, AND'THOSE SHOW N'ON THE RECORDS EXAMINED ARE SHOWN WITH THEIR APPROXIMATE LOCATION AND EXTENT. 2. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE NATURE OF EXISTING GROUND AND/OR THE FINISHED GRADE IN THE VICINITY OF THE PROPOSED CONSTRUCTION AREA'IMMEDIATELY PRIOR TO CONSTRUCTION. 3: THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES OR STRUCTURES FOUND AT THE SITE. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE OWNERS OF THE UTILITIES OR STRUCTURES CONCERNED BEFORE STARTING WORK. 4. THE CONTRACTOR ' SHALL. UNCOVER ALL UTILITIES THAT HE MAY BE. JOININGs CROSSING OR PARALLELING PRIOR TO ANY CONSTRUCTION TO VERIFY BOTH HORIZONTAL AND VERTICAL LOCATIONS.. ANY CONFLICT OR DISCREPANCY SHALL BE BROUGHT TO THE ENGINEER'S ATTENTION PRIOR TO CONSTRUCTION, OTHERWISE THE CONTRACTOR ACCEPTS FULL RESPONSIBILITY FOR ANY COSTS OF RELOCATION OR ADDITIONAL COSTS OF CONSTRUCTION. 1 IMPROVEMENT TRACT N0. 12246 FONTANA, CALIFORNIA k-1 1 No ITEM QUANTITY UNIT 1 CONSTRUCT PRE.—CAST MANHOLES PER CITY OF FONTANA 2 j STANDARD DETAIL 112 FA 2 CONSTRUCT 8" SEWER TERMINAL CLEANOUT PER CITY OF FONTANA STANDARD DETAIL 128, 3 CONSTRUCT 4" SEWER LATERAL PER CITY OF 'FONTANA STANDARD DETAIL 125,1 L./c 4 INSTALL 8" VITRIFIED CLAY PIPE L.' 5 INSTALL 10" VITRIFIED CLAY PIPE j/ Z_ 6 ADJUST MANHOLE AND CLEANOUT COVERS TO NEW GRADE 0