Loading...
HomeMy WebLinkAbout2509-TS-1.tifOD m a m 0 rT- FF w m / Q z Q z 0 LL_ / U) U II CONDUCTOR i I I I I i I I I I I E i I I i 1 i I 1 I I 1 I 1 t I I I I I I ! Jh 0 TABLE i i I I 01 02 1 03 04 AM F AF n,& I mic - ME IN - FAI FA AM FA m I Me 29A-5-80 05 06 07 08 Marlay Ave 3 -MAS SV -1 -T SP -1 -CS 04 N 13.5' 4' O 1 A 10 --- --- --- --- --- TV -1-T SP -1 -CS 06 E 15' 4' Q 26A-4-80 35' 45' 15' 250W Mulberry Ave 2 -MAS SV -1 -T SP -1 --CS 06 E F- 21' 4' O 1A 10 --- --- --- --- --- TV -1 -T SP -1 -CS 08 S 23.5' 4' O 129A-5-80 35' 50' 15' 250W Marlay Ave 3 -MAS SV -1 -T SP -1 -CS 0.8 S F- 8.5' 6.5' O 1A 10 --- --- --- --- --- TV -1-T SP -1 -CS 02 W 9' 4' O 24A-4-80 35' 35' 15' 250W Mulberry Ave 2 -MAS SV -1-T SP -1 -CS 02 W E- 11' 4' O 1A 10' --- --- --- --- --- TV -1-T SP -1 -CS 04 N 10' 4' ,, .. ; OOODOOOOODi ..: � � 0000000000 1 "607-11:11 __OPTICOM CABLE CONDUITI ®®®®®®®®®® PHASE DIAGRAM I I 1 I I I I ! i I I I I i I I I I I E i I I i 1 i I 1 I I 1 I 1 t I I I I I I ! Jh 0 I i i I I 01 02 1 03 04 LUM.M.A. 4 PED PHASE QUAD ARROW A B O 29A-5-80 05 06 07 08 I I 1 I I I I ! i I I I I i I I I I I E i I I i 1 i I 1 I I 1 I 1 t I I I I I I ! Jh 0 I i i I I INSTALL 1 1/2"C, 12PR #22 SIC I TO JURUPA AVE, APPROX. 2700' t TO t ' { SEE INTERCONNECT PLAN, SHEET TS -3` - ' FOR CONTINUATION. 12' 48' 146'' r - 16 12' 12' � 11' 13' 1 �' 14' I l I I I I I { z I I ! I- ~ Uj X { t > W z w i i I j Q 8 t I NOTE: PED PUSH BUTTON COMMON AND LUMINAIRE CONDUCTORS MAY BE SPLICED, SIGNAL COMMON (#10) AND #14 SIGNAL CONDUCTORS i 6 ARE TO BE LANDED ON TERMINAL BLOCKS ON POLLS. 4 4 # I 2�- * BELDEN #8281 COAXIAL CABLE 6 3 _ _.. O ** 14/3 VNTC CABLE !�' # WADI AV AVEN U E Q LL_ 0 I~ I� z V) E-' POLE SCHEDULE STANDARD LUMINAIRE (HPSV) S.N.S. LEGENfJ PED PUSH BTN LOCATION REMARKS No. TYPE HEIGHT SIG.M.A. LUM.M.A. VEHICLE PED PHASE QUAD ARROW A B O 29A-5-80 35' 50' 15' 250W Marlay Ave 3 -MAS SV -1 -T SP -1 -CS 04 N 13.5' 4' O 1 A 10 --- --- --- --- --- TV -1-T SP -1 -CS 06 E 15' 4' Q 26A-4-80 35' 45' 15' 250W Mulberry Ave 2 -MAS SV -1 -T SP -1 --CS 06 E F- 21' 4' O 1A 10 --- --- --- --- --- TV -1 -T SP -1 -CS 08 S 23.5' 4' O 129A-5-80 35' 50' 15' 250W Marlay Ave 3 -MAS SV -1 -T SP -1 -CS 0.8 S F- 8.5' 6.5' O 1A 10 --- --- --- --- --- TV -1-T SP -1 -CS 02 W 9' 4' O 24A-4-80 35' 35' 15' 250W Mulberry Ave 2 -MAS SV -1-T SP -1 -CS 02 W E- 11' 4' O 1A 10' --- --- --- --- --- TV -1-T SP -1 -CS 04 N 10' 4' Co un try Side Dr. 2,..EXISTING RIGHT-OF-WAY P EXISTING RIGHT -OF -WAY ---a,08 �6P 05 1 I j P 11 O N #6 0 `! 2' 02 2 6 N I i 1W7 - -- -- -- -- -- -- -- 5] F=16' 5 C� 71 ' 'A00 N 08 1 'vel — -- -- -- --- -- -- -- -- -- -- -- -- -- - -- -- -- -- -- - -- -- - -- '-`2 -- -- -- -- -- -- -- ---- -- -- -- -- -- -- -- -- -- - - - -- -- -- - -- --., __ __ _ -- -- -- -- -- - MUL FERRY AVENUE 10+00.00 ; N ' i Y ----------------------------------------------------------------------.--. ... --- --' - _ -- -- -- ' _ _ _ _ _._ 4 _ _ i i MARLAY AVENUE 52+69.63 T -------------------- J ----------------------------------------- -- -- -- -- -- -- _ - __ _ -- -- -- -- -- -- -- -- -- -- -- -- -- -- - -- - --- - - - -- -- -- -- - -- -- -- -- -- - -- -- -- -- 00 L.L I 1 I 7 1 I 50 — — — -� — -- — - i I 7 - - _- _ - _- -- _- - + _ _ — — — �- — 03 1 , ' -7 N 4 2"C, SIC ii I I LL 4 I _ 04 I , N AB__j i - - -- -- --- __j -- - --- -- --, 5 I ` - _ -- --- - - - -- ----- -- - - -_ _- __.—.— 03 I , i ' 1 ' 04 t i N 42 RCP 6 F=17 , �1 R2(40) cv 5 , , , , EXISTING RIGHT-OF-WAY 04P 06 06 06 4 1�1 1 I 1 02P EXISTING RIGHT-OF-WAY 6 ♦ 06P� 5 I I I _ #6 O8 GENERAL NOTES _ II CONSTRUCTION NOTES 0 6 ;41 ' 1. TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE STATE OF CALIFORNIA STANDARD 8 - - - !I < - I - 6 ❑1 INSTALL CONTROLLER ASSEMBLY INCLUDING TYPE "P" CABINET, ECONOLITE TYPE 90 ASC/2-1000 SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 1992). 2"C, 2 -SIC( -- _� AB it `� 71 Q CONTROLLER AND APPURTENANT EQUIPMENT. SEE SPECIAL PROVISIONS FOR COMPLETE EQUIPMENT 9 2" C, ,SIC I LIST. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL EQUIPMENT REQUIRED TO PROVIDE 2. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL POTHOLE E CB III 1 o THE DESIRED OPERATION AS SHOWN ON THE PLAN, INCLUDING OPTICOM CABLE AND #14/03 VNTC TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE. HAND DIG I ' i POWER CABLE. INSTALL FOUNDATION PER CITY OF FONTANA STANDARD DETAIL #134. CONTRACTOR FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS. PHONE UNDERGROUND SERVICE ALERT AT 1 10 9 it = TO OBTAIN CONTROLLER /AU TOSCOPE ASSEMBLY FROM THE CITY AT CONTRACTOR'S EXPENSE. 800/422-4133, TWO (2) WORKING DAYS BEFORE DIGGING. - 2"C, 2#6 2"C, 4#10 �I 3. ALL PULLBOXES SHALL BE NO. 5 AND CONDUIT SHALL BE 2" RIGID METAL EXCEPT AS SHOWN. ALL ► II ' ; + I ❑2 INSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE INCLUDING THE FOLLOWING: 120-240 V HI HEA SHALL B PER SPECIAL PROVISIONS. 15 12 12 4� 12 , 12 12 14':; I z %'- SINGLE PHASE SERVICE WITH 120 V METERED SIGNAL CIRCUIT, 120 V UNMETERED LIGHTING VEHICLE DS L E SP L 2 1 F- W North CIRCUIT 100A MAIN CIRCUIT BREAKER 50A SIGNAL CIRCUIT BREAKER 30A LIGHTING CIRCUIT V) , , 4. CONTRACTOR SHALL COORDINATE ELECTRIC SERVICE DETAILS AND SCHEDULING WITH THE SOUTHERN I ' II w Lr 1 "=20' BREAKER, PEC FOR LIGHTING IN SERVING UTILITY PORTION OF ENCLOSURE, CABINET ENCLOSURE CALIFORNIA EDISON COMPANY WELL IN ADVANCE OF NEED. W TO BE UNPAINTED RAW ALUMINUM PER SPECIAL PROVISIONS. 5. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE CITY TRAFFIC ENGINEER OR HIS DESIGNEE FOR EXACT I III ' 20 10 0 20 40 I , EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. F31INSTALL 3" CONDUIT WITH PULLROPE AND 36" PVC SCHEDULE 80 RISER SWEEP FROM 6. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS, AND SIDEWALK AFFECTED ! II <1A l ELECTRICAL SERVICE POINT TO SERVICE ENCLOSURE PER EDISON REQUIREMENTS. BY THE CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER. 1' a I I GAS l ❑ INSTALL UNI -DIRECTIONAL, SINGLE CHANNEL OPTICAL DETECTOR (OPTICOM MODEL 7. CONTROLLER CABINET SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. MODIFY SPRINKLER II M511 OR EQUAL) PER CITY OF FONTANA STANDARD DETAIL NUMBER 138. SYSTEMS IF NECESSARY. lil �► I �, o II I I 5 INSTALL AUTOSCOPE CAMERAS AND BRACKETS PER SPECIAL PROVISIONS AND CITY OF FONTANA 8. CONTRACTOR SHALL MASK OR BAG ALL CONFLICTING SIGNS. CONTRACTOR SHALL REMOVE CONFLICTING I I I ❑ MARKINGS AND STRIPING BY WET SAND BLASTING OR AS DIRECTED BY THE CITY TRAFFIC ENGINEER. _ STANDARD DETAIL NUMBER 133. I ' I , I I 9. CONTRACTOR SHALL REFER TO THE CITY TRAFFIC ENGINEER IN THE EVENT OF A CONFLICT OR POTENTIAL 0:� II E I I F6]FURNISH & INSTALL TRAFFIC VISIBILITY MARKER PER CITY OF FONTANA STD. NO. 142. (QUANTITY - 1). CONFLICT WITH THESE PLANS AND/OR SPECIFICATIONS FOR THIS PROJECT. EDISON " 1 11 I 13' 47' ' '46' I 1 ❑7 FURNISH &INSTALL R73-3 SIGN ON MASTARM. (QUANTITY - 2). 10. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA ENGINEERING i I r DIVISION PRIOR TO COMMENCEMENT OF WORK. w I ' A' 11. ALL TRAFFIC CONTROL, WORK ZONES AND LANE CLOSURES SHALL BE COMPLETELY DELINEATED BY ❑8 REMOVE EXISTING LUMINAIRE (BY SCE). CHANNELIZATION DEVICES AND SHIELDED BY BARRIERS TO EXCLUDE VEHICLE AND/OR PEDESTRIAN TRAFFIC. 9 ALL WORK, PROCEDURES, MATERIALS AND EQUIPMENT FOR TRAFFIC SIGNING AND STRIPING SHALL CONFORM❑ TO THESE PLANS, THE STANDARDS AND SPECIFICATIONS OF THE CITY OF FONTANA AND THE STANDARDS INSTALL 1 1/2"C TO EL EAVE., & REMOVE EXISTING ELECTROLIER (BY SCE). 1 INSTALL 12PR#22 SIC TOO CHERRY Y AVE. AND SPECIFICATIONS OF THE STATE OF CALIFORNIA. I SEE INTERCONNECT PLAN, SHEET TS -3 12. REMOVAL OF ALL EQUIPMENT AND TRAFFIC CONTROL SHALL BE COORDINATED WITH THE CITY OF FONTANA FOR CONTINUATION. TRAFFIC SECTION. STOP SIGNS WILL BE REMOVED ONLY BY CITY FORCES. TWO (2) WORKING DAYS WRITTEN NOTICE IS REQUIRED TO COORDINATE WORK WITH CITY FORCES. �� �e'N' 11A� . 2- P7 17, 6-U 2 )Mir M lz,J