HomeMy WebLinkAbout2508-9.tifB. THE OUTSIDE DIAMETER OF THE LATERAL MUST BE LESS THAN OR EQUAL TO 1/2 THE INSIDE DIAMETER OF THE MAIN LINE. IF THE UPSTREAM AND DOWNSTREAM DIAMETERS OF THE MANHOLE ARE NOT THE SAME, THE GOVERNING INSIDE DIAMETER OF THE MAIN LINE SHALL BE CONSIDERED TO BE THAT WHERE THE EXTENDED CENTER LINE OF THE LATERAL ENTERS THE MANHOLE. C. IN NO INSTANCE SHALL THE INSIDE DIAMETER OF THE LATERAL TO THE MANHOLE BE GREATER THAN 30". 13. MANHOLE FRAME AND COVER SHALL CONFORM TO STANDARD PLAN 630 - UNLESS OTHERWISE SHOWN. 14. MANHOLE SHAFT SHALL CONFORM TO STANDARD PLAN 324 UNLESS OTHERWISE SHOWN. 15. WHERE A MANHOLE SHAFT - 36 -INCH WITHOUT REDUCER IS SPECIFIED REFER TO STANDARD PLAN 326. 16. WHERE A PRESSURE MANHOLE SHAFT - WITH ECCENTRIC REDUCER IS SPECIFIED REFER TO STANDARD PLAN 328. 17. WHERE A PRESSURE MANHOLE SHAFT - 36 -INCH WITHOUT REDUCER IS SPECIFIED REFER TO STANDARD PLAN 329. THE FOLLOWING STANDARD PLANS ARE INCORPORATED HEREIN: 324 MANHOLE SHAFT - WITH ECCENTRIC REDUCER 'LL( I C SHAFT Z6 -1 GH WIT-1190T RE-90G Ems' 630 24 -INCH MANHOLE FRAME AND COVER 633 36 'Nell 635 STEEL STEP AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER STANDARD PLAN 320-0 SHEET 3OF3 MANHOLE PIPE TO PIPE MAIN LINE ID = 36 OR LARGER NOTES I. THIS JUNCTION STRUCTURE SHALL BE USED WHEN THE OUTSIDE DIAMETER OF THE LATERAL IS GREATER THAN 1/2 THE INSIDE DIAMETER D OF THE MAIN LINE: OR WHEN THE INSIDE DIAMETER B OF THE LATERAL IS GREATER THAN 24'. B SHALL NOT EXCEED 3/4 D OR 39'. 2. IF THE MAIN LINE IS A REINFORCED MONOLITHIC ARCH STORM DRAIN, D SHALL REFER TO THE CLEAR SPAN OF THE ARCH. REINFORCING STEEL SHALL BE CUT AND BENT INTO THE JUNCTION STRUCTURE IN THE SAME MANNER AS FOR A PIPE. A CONCRETE CRADLE IS NOT REQUIRED FOR A REINFORCED MONOLITHIC ARCH. 3. STATIONS SHOWN ON THE PROJECT DRAWINGS FOR LATERALS APPLY AT THE INTERSECTION OF CENTER LINES OF MAIN LINE AND LATERAL. STATIONS SHOWN ON THE PROJECT DRAWINGS FOR CATCH BASIN CONNECTOR PIPES APPLY AT THE INTERSECTION OF THE INSIDE WALL OF THE MAIN LINE WITH THE CONNECTOR PIPE CENTER LINE. 4. VALUES FOR A. B. C AND D SHALL BE SHOWN ON THE PROJECT DRAWINGS. ELEVATION R AND ELEVATION S SHALL BE SHOWN ONLY WHEN REQUIRED PER NOTE 5. 5. a. ELEVATIONS R AND S NEED NOT BE SHOWN ON THE PROJECT DRAWINGS IF THE INLET PIPE IS TO ENTER THE MAIN LINE RADIALLY. b. ELEVATION R SHALL BE SHOWN ON THE PROJECT DRAWINGS ONLY IF A STUB IS TO BE PROVIDED IN THE MAIN LINE FOR FUTURE CONNECTION OF AN INLET PIPE. c. ELEVATION S SHALL BE SHOWN ON THE PROJECT DRAWINGS IF AN INLET PIPE IS TO ENTER THE MAIN LINE OTHER THAN RADIALLY. INLET PIPE SHALL BE LAID ON A STRAIGHT GRADE FROM ELEVATION S TO THE CATCH BASIN OR GRADE BREAK IN LINE. 6. THE INLET PIPE SHALL ENTER THE MAIN LINE RADIALLY UNLESS OTHERWISE INDICATED. THE INLET PIPE MAY ENTER THE MAIN LINE OTHER THAN RADIALLY IF ANGLE A IS GREATER THAN 450, B IS LESS THAN OR EQUAL TO 24' AND THE OUTSIDE DIAMETER OF THE INLET PIPE IS LESS THAN 1/2 D: OTHERWISE, STANDARD PLAN 340 SHALL BE USED. 7. NO MORE THAN ONE OPENING SHALL BE MADE IN ANY ONE SECTION OF PIPE. 8. THE OPENING FOR THE BREAKOUT SHALL BE RECTANGULAR AND CUT NORMAL TO THE PIPE SURFACE WITHOUT DAMAGING THE REINFORCING STEEL. THE TRANSVERSE REINFORCEMENT OF THE MAIN LINE SHALL BE CUT AT THE CENTER OF THE OPENING AND BENT INTO THE TOP AND BOTTOM SLABS OF THE SPUR. 9. THE MAIN LINE SHALL BE REINFORCED WITH A CONCRETE CRADLE AND ENCASEMENT (AS APPLICABLE). A CONCRETE ENCASEMENT IS REQUIRED IF A JOINT IN THE MAIN LINE FALLS WITHIN THE LIMITS OF THE CRADLE. THE CONCRETE ENCASEMENT SHALL EXTEND 12' ABOVE THE TOP OF THE MAIN LINE AND TO THE LIMITS OF THE CRADLE. IF CONNECTING TO AN EXISTING STORM DRAIN, PORTION OF CRADLE OPPOSITE INLET MAY BE OMITTED. 10. REINFORCING STEEL SHALL CONFORM TO ASTM A 615, GRADE 40, AND BE PLACED 1 1/2' CLEAR FROM CONCRETE SURFACES, UNLESS OTHERWISE SHOWN F BARS SHALL BE CARRIED TO A POINT NOT LESS THAN J DISTANCE FROM CENTER LINE WITH J = 7D/12 + 6". II. FLOOR OF THE SPUR SHALL BE STEEL -TROWELED TO THE SPRING LINE OF THE SPUR. AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER STANDARD PLAN 331-1 SHEET 2OF2 JUNCTION STRUCTURE - PIPE TO PIPE (INLET ID >_ 24" OR OD >1/2 MAIN LINE ID) W: \ FIESTA\ OWGS\ DETAIL 1. DWG FINISHED GRADE OR MANHOLE FRAME SPECIFIED ELEVATION MANHOLE FRAME AND COVER PER COLLAR. CLASS C MORTAR AND COVER PER STD. PLAN 630 .I STD. PLAN 630 ivl STD. CONCRETE RINGS, 3'. I iv� 1� 6' OR 16' IN THICKNESS, L T--. SEE NOTE 6 -- R - 2' ao -- -WHEN POSSIBLE USE �4.' R - 2" •4" M 4-2 1/2' RINGS 1 1 - OR EQUIVALENT v 2 24' 18' MAXIMUM 24' 6" •4 WIRE DIA. HOOPS SEE RING SECTION z I FOR JOINT DETAILS ( r 15• � 5' �- 72 R E Q'U RED z_ I 6• N`\N N ' � 1�5 - s2 TIE BARS, 4 REQUIREDN hS, 15/16' - ECCENTRIC PRECAST i M - CONCRETE CONE I VARIABLE LENGTH PRECAST CONCRETE SECTIONS. 6• MIN. THICKNESS FOR 3 1/8' 36' DIA. PLAIN CONCRETE. 4' MIN. THICKNESS MINIMUM FOR REINFORCED CONCRETE I 36' SPECIAL MH RCP WITH A CIRCULAR CAGE AND WOOD MINIMUM ANY STANDARD 36' PIPE END DIA. N �"� 5• CLASS-C'PE MORTART' VERTICAL SECTION OF PLAIN CONCRETE ECCENTRIC MANHOLE SHAFT VERTICAL SECTION OF REINFORCED CONCRETE ECCENTRIC MANHOLE SHAFT 2 1/2' RINGS SHALL BE REINFORCED WITH TWO 1/4' ROUND STEEL HOOPS: 6' AND 8' RINGS SHALL BE REINFORCED WITH FOUR HOOPS, TIED WITH NO. 14 5 3/4' GAUGE WIRE 8' OC 2 1/8" 1 1/2" M lD N Ln N co - � o N -INSIDE DIAMETER 24' LLI 1 1/4' MI 2 I/2" 1' 1 3/4" 1/4' 1/4' CROSS SECTION OF REINFORCED CONCRETE RING AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER PROMULGATED BY THE APWA-AGC JOINT COOPERATIVE COMMITTEE 1992 MANHOLE SHAFT WITH ECCENTRIC REDUCER STANDARD PLAN 324-0 USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION 12 4 SHEET 1 OF 2 ROUND EDGES TO RADIUS OF APPROXIMATE ID OF LATERAL. MAXIMUM 36' - A 81 B BARS TABLE FOR DIMENSIONS AND BAR SIZES 02 F OR OR B T (INCHES) (INCHES) CC N a 00 m 0 0 a a m u. a: 0 o X a 12 4 0 0 ;) io - LONGITUDINAL 15 4 1/4 18 4 1/2 21 5 24 5 1/4 27 5 1/2 30 6 33 6 1/4 36 6 1/2 39 7 42 7 1/2 0 0 0 vi 45 7 3/4 48 8 51 8 1/2 54 9 57 9 1/4 60 9 1/2 63 10 66 1 10 1/4 69 10 3/4 72 11 78 II 3/4 84 12 1/2 90 13 1/4 V 0 ;'� p • V 0 ca p 96 14 102 15 1/2 108 16 114 16 1/2 120 17 126 17 132 17 1/2 138 17 1/2 144 7r 18 P SEE NOTE 8 STATION--� STATION PT. NII, s3 OR •4 �)k 0 18. OC D BARS II I ELEV. ELEV. f STA. STA. I II �-- 6 t LATERAL / c, CONNECTOR USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION / PIPE SHEET 1 OF 2 WHEN D2 IS 60' OR LONGITUDINAL SECTION MORE A BARS D BARS �i '3 OR m4 F BARS v 5 1/2 ROUND EDGES M 6• TO 3' R 6 1/2 I ELEV. R I ELEV. S u - 7 I •4018' OC. BOTH WAYS, TO BE USED WHEN B IS 60" OR MORE P MAIN LINE SECTION N' -N" -N"' PROJECTED ON M -M -N"' 4 MAIN LINE m STATION N' -3 OR •4. SEE NOTE 4 D BARS PLAN 03 OR #4 II I ELEV. ELEV. f STA. STA. I II �-- AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER PROMULGATED BY THE APWA-AGC JOINT COOPERATIVE COMMITTEE 1992 `� 44018' OC, BOTH STANDARD PLAN 340-0 USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION WAYS, TO BE USED SHEET 1 OF 2 WHEN D2 IS 60' OR LONGITUDINAL SECTION MORE A BARS D BARS �i '3 OR m4 F BARS 27 5 1/2 30 •3 OR •4 °D 018" OC B BARS 6 1/2 I ELEV. R I ELEV. S 39 7 I •4018' OC. BOTH WAYS, TO BE USED WHEN B IS 60" OR MORE �I�_ MAIN LINE SECTION N' -N" -N"' PROJECTED ON M -M -N"' AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER PROMULGATED BY THE APWA-AGC JOINT COOPERATIVE COMMITTEE 1992 TRANSITION STRUCTURE PIPE TO PIPE STANDARD PLAN 340-0 USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION 15 SHEET 1 OF 2 PLANS PREPARED FOR FIESTA DEVELOPMENT, INC. 7072 GARFIELD AVENUE HUNTINGTON BEACH, CA. 92648 (714) 842-5527 IZ141 REVISIONS ENGINEER CITY ADDDAVA1 n=- ADDDA% NOTES I. UNLESS OTHERWISE INDICATED THIS STRUCTURE SHALL CONFORM TO ASTM C 478 AND ALL CONCRETE SHALL BE PER SSPWC. 2. MANHOLE FRAME AND COVER SHALL CONFORM TO STANDARD PLAN 630. 3. ALL JOINTS SHALL BE SEALED BY FILLING THE ANNULAR SPACES WITH CLASS C MORTAR. THE INSIDE OF THE SHAFT AT EACH JOINT SHALL BE WIPED CLEAN OF EXCESS MORTAR. 4. PROTECTIVE PLASTIC LINER (T LOCK) OR ENGINEER -APPROVED COAT- INGS WHERE REQUIRED BY THE PROJECT DRAWINGS SHALL BE IN ACCORDANCE WITH SSPWC AND THE MANUFACTURER'S DIRECTIONS. 5. STEPS SHALL CONFORM TO STANDARD PLAN 635 OR 636. THE TOP STEP SHALL BE PLACED DIRECTLY BENEATH THE MANHOLE FRAME. UNLESS OTHERWISE. SHOWN, STEPS SHALL BE UNIFORMLY SPACED 14" TO 15" OC. 6. THE ECCENTRIC MANHOLE SHAFT REDUCER AND RINGS MAY BE PLAIN CONCRETE. FOR PLAIN CONCRETE SECTIONS THE MINIMUM THICKNESS SHALL BE 6". 7. THE PRECAST CONCRETE MANHOLE STRUCTURES WILL BE INSPECTED BY THE ENGINEER WHO WILL INDICATE ACCEPTANCE FOR SHIPMENT TO THE JOB BY MARKING THE STRUCTURES WITH THE AGENCY'S STAMP. 8. THE VERTICAL SIDES OF THE MANHOLE SHAFT AND THE ECCENTRIC REDUCER SHALL BE LOCATED ABOVE AND IN LINE WITH THE SIDE OF THE STORM DRAIN CONDUIT. THE FOLLOWING STANDARD PLANS ARE INCORPORATED HEREIN: 630 24 -INCH MANHOLE FRAME AND COVER 635 STEEL STEP 636 POLYPROPYLENE PLASTIC STEP AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER STANDARD PLAN 324-0 MANHOLE SHAFT WITH ECCENTRIC REDUCER 12 SHEET 2 OF 2 NOTES I. THE HORIZONTAL ANGLE OF CONVERGENCE OR DIVERGENCE, 0, SHALL NOT EXCEED 5°45'. 2. VALUES FOR A, B, C. DI AND D2 ARE SHOWN ON THE PROJECT DRAWINGS. ELEVATION R AND ELEVATION S ARE SHOWN WHEN REQUIRED BY NOTE 10. 3. FLOOR OF STRUCTURE SHALL BE STEEL TROWELED TO SPRING LINE. 4. REINFORCEMENT STEEL SHALL CONFORM TO ASTM A 615, GRADE 40, AND SHALL TERMINATE 1 1/2" CLEAR OF CONCRETE SURFACES UNLESS OTHERWISE SHOWN. LONGITUDINAL BARS SHALL BE «3 OR *4 SPACED 18" OC OR LESS. 5. ELEVATIONS APPLIES AT INSIDE WALL OF STRUCTURE. 6. TRANSITION STRUCTURE SHALL BE POURED IN ONE CONTINUOUS OPERATION, EXCEPT THAT THE CONTRACTOR SHALL HAVE THE OPTION OF PLACING AT THE SPRING LINE A CONSTRUCTION JOINT LONGITUDINAL KEYWAY. 7. THE LENGTH OF THE STRUCTURE MAY BE INCREASED AT THE OPTION OF THE CONTRACTOR TO MEET RCP ENDS, USING D BARS, LONGITUDINAL AND BOTTOM REINFORCEMENT IN EXTENDED PORTION OF SAME DIAMETER AND SPACING AS SPECIFIED IN THE TABLE, BUT ANY CHANGE IN THE LOCATION OF SPUR MUST BE APPROVED BY THE ENGINEER. 8. EMBEDMENT P SHALL BE AS SPECIFIED IN THE TABLE, UNLESS OTHERWISE SHOWN ON THE PROJECT DRAWINGS. 9. WHEN THERE IS NO SPUR REQUIRED, A & B BARS SHALL BE OMITTED. 10. WHEN ELEVATION R AND ELEVATION S ARE NOT SHOWN ON PROJECT DRAWINGS, INLET PIPE SHALL ENTER MAIN LINE RADIALLY. WHEN INLET PIPE ENTERS MAIN LINE OTHER THAN RADIALLY, ELEVATION S SHALL BE SHOWN ON PROJECT DRAWINGS, AND INLET PIPE SHALL BE LAID ON A STRAIGHT GRADE FROM ELEVATION S TO CATCH BASIN OR GRADE BREAK IN INLET LINE. ELEVATION R SHALL BE SHOWN ON PROJECT DRAWINGS ONLY WHEN STUB IS TO BE PROVIDED IN MAIN LINE FOR FUTURE CONSTRUCTION OF INLET PIPE. 11. THE MAXIMUM COVER ABOVE THIS STRUCTURE SHALL BE 25'. IF THE COVER EXCEEDS 25' A SPECIAL STRUCTURE SHALL BE DESIGNED FOR THE COVER AND DETAILED ON THE PROJECT DRAWINGS. AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER STANDARD PLAN 340-0 TRANSITION STRUCTURE PIPE TO PIPE 12 SHEET 2 OF 2 BENCHMARK BM #613 SIERRA AVE. AT MAIN DRIVE JURUPA PARK TOP F.H. 1102.18 ELEVATION: 1102.18 El 7011f.1501 QUAIL STREETP.O.BOX 3030 NEWPORT BEACH, CALIFORNIA 92660-9020 .0 SHAHAB NAZARIE,R.C.E. DATE (EXPIRES6/30/00) aL MAIN LINE RCP OR REINFORCED MONOLITHIC ARCH, SEE NOTE 2 ' Vq J SEE NOTE 10 H I H D , *,'v I 3' MIN. 6� t LATERAL/ CONNECTOR PIPE G BARS 0406' OC a m co ~ _j w z ROUND w0 �- O L EDGE ---- -- #3 OR s4 0 18' OC w z Z TO 3' R TIE BARS z N w ccnn I I E AND F BARS o X V m tl I J N_ cD --I- STA. POINT CONNECTOR PIPE SEE NOTE 3 STA. POINT LATERAL SEE NOTE 3 PLAN SPUR REINFORCING STEEL 3' MIN. / SPRING LINE /ROUND II EDGES ELEV. S UNDISTURBED EARTH H H SECTION Z -Z •3 OR @4 0 18' OC TIE BARS t- 0 OC -r mELEV. R E B F BARS •5 0 3' OC - CONCRETE CRADLE. 420-C-2000, SEE NOTE 9 15 0 3' OC, SEE NOTE 8 TABLE OF VALUES FOR T B (INCHES) T (INCHES) 12 5 15 5 18 5 21 5 24 5 i/2 27 5 1/2 30 6 33 6 1/2 36 6 I/2 39 7 SECTION M -M BARS G BARS AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER PROMULGATED BY THE APWA-AGC JUNCTION STRUCTURE -PIPE TO PIPE STANDARD PLAN JOINT COOPERATIVE COMMITTEE 1992 (INLET ID >_ 24" OR OD > 1/2 MAIN LINE ID) 331-1 33'-48' 6' USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION REV. 1993 SHEET 1 OF 2 s• 2' MORTAR CAP- B CONCRETE BLOCK --� - 5' MINIMUM (SEE NOTE 6) A � A A A d I A rl . A C). A n. d'.n. A n a n n n n n �- 2' -_1- a �e e w I 12' 3 CO�URSE MAXIMUM I2, 1 MAXIMUM SLOPE A B 0'-6' 2' 7'- 16' 4' 17'-32' 6' 33'-48' 6' 520-A-2500 PCC NOTES: 1. CONCR AND CONCRETE BLOCK SHALL BE PE SSPWC. 2. CONC TE BLOCKS SHALL BE PLACED WHILE THE OOTING IS ST L FRESH. ALL CELLS TO BE FILLED SOLID WI GROUT D RODDED SO GROUT IS MONOLITHIC WITH FRESH OTING. OMIT MORTAR FROM VERTICAL JOINTS IN FIRST COURS ABOVE FINISHED GRADE ON 32' CENTERS FOR WEEP HOLE 4. POUR FOOTING AGAINST UNDISTURBED NATURAL SOIL. 5. NO LIVE LOAD SURCHARGE ALLOWED ON RETAINED SOIL. 6. TOP OF FOOTING MAY BE PLACED PARALLEL TO PARKWAY GRAD IF STREET GRADE IS RELATIVELY FLAT AND UNIFORM. (MAX. 5%) AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAP R PROMSTAND JOINT COOPERATIVED BY AGC JOINT COOPERATIVE COMMITTEE COMMAPWAITTEE CONCRETE BLOCK SLOUGH WALL D PLAN 622 - 1993 SHEET 1 OF 1 USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION Qy,pFESS/Oryq� V ��4ti�P�PB lVq���i � C 36943 rTi * Exp. 6/30/00 `rte cw ��\P qTF OF C\F CITY OF FONTANA CALIFORNIA PUBLIC WORKS DEPARTMENT DRAWN BY: SCALE: PYH AS NOTED DETAIL SHEETS DESIGNED BY. DATE: SN CHECKED BY: APPROVED: 1��� S = /Z. 9b DWG. NO. SHT. NO. SN For CITY ENGINEER R.C.E. 25126 2508 ,9 Ofig