Loading...
HomeMy WebLinkAbout2505-2.tifVERT: 1.. , = 4` 1�7 I CONSTRUCTION NOTES: HORZ: " = 20' I I ti C „ 2 9 STA. 10+11.97 C/L CATCH BASIN #2 1355.33 TC 1354.33 FL W=27' V=5.00' P. E. 1357. 7 CITY OF FONTANA BENCHMARK NO. 378, CIRCUIT NO. 67-5, 30D NAIL IN POWR POLE (NO NUMBER), SOUTHWEST CORNER OF BEECH & FOOTHIL_L BLVD., DATE SEPTEMBER 1967 ELEVATION 1267.84 1 1358. TW 1354.4 TF 1j. qj s 1>1j1 0 .0 i w � STA. 10+00.00 C/L FOXWORTH STREET STA. 10+00.00 PLUMROSE STREET STA. 10+50.00 C/L CATCH BASIN #1 1355. 74 TC 1354. 74 FL W=14' V=6.00' �J o ri z �J � I � �� PROPOSED 8" WATER MAIN � N 89'58' 10" W -*-*C/[---F7-0-X-W-0-R-TF+.-S-T-RE-E-T-------- PROPOSED 8" SEWER MAIN I m STA. 10+15.21 C/L 36" CMP DETENTION BASIN SEE SHEET 3 :••■ CA CENTERLINE RCP REINFORCED CONCRETE PIPE CMP CORRUGATED METAL PIPE TC TOP -OF -CURB INV INVERT FL FLOW LINE PE PAD ELEVATION W WIDTH TW TOP -OF -WALL ELEVATION TF TOP -OF -FOOTING ELEVATION WI WROUGHT IRON BACKFILL SHALL BE COMPACTED TO A MINIMUM OF 906. ZA II Val 0.0 H,,,- 9 0919�1 CIVIL ENGINEERING CONS U-L2"A'4NTS ENGINEERING - PIANNING - SURVEYING CIVILCADD SOFTWARE SUPPORT 680 t t a t i t ! 1 • t,• ++ 885-3800 7 CONSTRUCT 24 DIAMETER R.C.P., D -LOAD PER PROFILE 8 CONSTRUCT 36" DIAMETER C. M. P. DRAIN PIPE, 16 GAUGE CONSTRUCT CATCH BASIN PER CITY OF FONTANA STD. NO. 121, MODIFIED FOR 4" DEEP LOCAL DEPRESSION 10 CONSTRUCT LOCAL DEPRESSION PER CITY OF FONTANA STD, NO 121, MODIFIED TO A 4" DEEP DEPRESSION AT FLOW LINE 11 CONSTRUCT GROUTED RIP RAP, 9" NOMINAL ROCK IN CLASS 'B' 8" THICK CONCRETE 12 CONSTRUCT 4' -WIDE CONCRETE GUTTER PER DETAIL "A", SHEET 1 19 CONSTRUCT CONCRETE COLLAR PER DETAIL "C", SHEET 2 tt A f% t`! R [ -r 7 K11 i U Z) [J AIN ELEVATION #4 BARS 12" 0. C. EACH WAY REINFORCING 4 BAR 18" i `-\C. M. P. #4 BARS -` -C\j #4 BAR NOTES; 1. HEADWALL SHALL BE CONSTRUCTED OF CLASS ' A' CONCRETE. 2. ADJACENT SLOPES SHALL BE 1-1/2 TO 1 MAXIMUM. 3. ALL EXPOSED CORNERS SHALL BE ROUNDED TO 3/4" RADIUS. DETAIL "D" -- WING -TYPE HEADWALL 12" ExplOWILM1. � C ILS Fc a #5 BARS ELEVATION USE CLASS 'A' CONCRETE SECTION D TAIL 11 C11 -® RCP COLLAR REVISIONS � --- }���� ,��f, En inear Cl y LLY - t s � Q��SSj Approval Date; Approval Dote: DRAWN BY w w' r. NJK �Oi � �tri LONNY L. CHECKED BY BD No. C -O 321 `y YOUNG 3t5 0 Jy! (e� % � No. C-043216 SCALE � L NNY YOU CECT 3 DATE Exp. 3/31/00 JOB No. �,�' �, CIVIL 965023 ' OF C DATE OF CALICO 28 JAN 97 N. T. S. TYPICAL AROUND POUR AGAINST UNDISTURBED NATURAL GRD. 2 x 12 x 12 CAP BLOCK 1/2"x 1" STRUC. STEEL TUBING 12 x 8 x 12 SPLIT 6„ 2"x 2" STRUC. TUBING FACE PILASTER 1.0 8' MAX. (RING SPLIT ON ALL 4 SIDES OR SLUMPSTONE) wi Zi -� 2" CLEAR ( TYP. ) z #3 TIE @ 2' O. C. miJ 3/4" x 3/4" STRUC. 1 n �Y STEEL TUBING 4" #4 0 CONC. O. C. MAX. (TYP) 4' m FOOTING 6` PILASTER ,- z PLAN VIEW o iw #4 CL co = as FOOTING LONG. STEEL 873 #4 (TYP) 3" CLEAR 3' -0" (TYP) 1/2% x 1" STRUC. STEEL TUBING 6" PILASTER DETAIL "E" -- W. I - /PILASTER FENCE_ N. T. S. CITY OF FONTANA, CALIFORNIA STORM DRAIN PLAN -TRACT 14293 scn lE: _ 20, FOXWORTH STREET DATE: APPROVED: ��i �.�� '7- -?,_ 977 DRw. No, MAY 1997 r-,,,, CITY ENGINEER RCE 25126 DATE 2505 SHEET 2 OF 4 DETAIL "E" NOTES; 1. USE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION LATEST 2. ALL MODIFICATIONS SHALL BE PERFORMED IN ACCORDANCE WITH ACI 318, ACI 530 AND UBC. 3. ALL VERTICAL CELLS ABOVE GRADE CONTAINING REINFORCING STEEL SHALL BE FILLED WITH GROUT. 4. ALL WALLS SHALL BE PLUMB AND ALL COURSES LEVEL. 5. BACKFILL SHALL BE COMPACTED TO A MINIMUM OF 906. 6. FOOTINGS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI CONCRETE @ 28 DAYS PER UBC SECTION 2609 LATEST EDITION. 7. CONCRETE MASONRY UNITS SHALL HAVE A SPECIFIED COMPRESSIVE STRENGTH (f'm) OF 1,500 PSI AND MEET OR EXCEED THE REQUIREMENTS OF STANDARDS SET IN UBC SECTION 2402(b)5 LATEST EDITION. 8. REINFORCING STEEL SHALL BE DEFORMED BARS HAVING A MINIMUM YIELD STRENGTH OF 40,000 PSI AND MEET OR EXCEED THE REQUIREMENTS SET FORTH IN UBC SECTION 2402(b)1O LATEST EDITION. 9. MORTAR SHALL CONFORM TO UBC TABLE 24-A LATEST EDITION. 10. GROUT SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI @ 28 DAYS AND CONFORM TO UBC TABLE NO. 24-B LATEST EDITION. 11. FOOTING TO BE POURED AGAINST UNDISTURBED NATURAL SOIL OR COMPACTED FILL. SIDES OF FOOTING SHALL BE VERTICAL. Q ��f-ESS' 12. ALL WROUGHT IRON SHALL BE TUBULAR SQUARE STEEL WELDED AT CONNECTIONS. GRIND AND PRIME. ENTIRE FENCE TO RECEIVE 2 COATS OF RUSTOLEUM. SEE NOR KIND rr► ARCHITECT FOR COLOR. NO. C-33736 13• 6' P I LASTERS TO BE PLACED 16' ON CENTER AND AT ALL ANGLE POINTS. ExplOWILM1. � C ILS Fc a #5 BARS ELEVATION USE CLASS 'A' CONCRETE SECTION D TAIL 11 C11 -® RCP COLLAR REVISIONS � --- }���� ,��f, En inear Cl y LLY - t s � Q��SSj Approval Date; Approval Dote: DRAWN BY w w' r. NJK �Oi � �tri LONNY L. CHECKED BY BD No. C -O 321 `y YOUNG 3t5 0 Jy! (e� % � No. C-043216 SCALE � L NNY YOU CECT 3 DATE Exp. 3/31/00 JOB No. �,�' �, CIVIL 965023 ' OF C DATE OF CALICO 28 JAN 97 N. T. S. TYPICAL AROUND POUR AGAINST UNDISTURBED NATURAL GRD. 2 x 12 x 12 CAP BLOCK 1/2"x 1" STRUC. STEEL TUBING 12 x 8 x 12 SPLIT 6„ 2"x 2" STRUC. TUBING FACE PILASTER 1.0 8' MAX. (RING SPLIT ON ALL 4 SIDES OR SLUMPSTONE) wi Zi -� 2" CLEAR ( TYP. ) z #3 TIE @ 2' O. C. miJ 3/4" x 3/4" STRUC. 1 n �Y STEEL TUBING 4" #4 0 CONC. O. C. MAX. (TYP) 4' m FOOTING 6` PILASTER ,- z PLAN VIEW o iw #4 CL co = as FOOTING LONG. STEEL 873 #4 (TYP) 3" CLEAR 3' -0" (TYP) 1/2% x 1" STRUC. STEEL TUBING 6" PILASTER DETAIL "E" -- W. I - /PILASTER FENCE_ N. T. S. CITY OF FONTANA, CALIFORNIA STORM DRAIN PLAN -TRACT 14293 scn lE: _ 20, FOXWORTH STREET DATE: APPROVED: ��i �.�� '7- -?,_ 977 DRw. No, MAY 1997 r-,,,, CITY ENGINEER RCE 25126 DATE 2505 SHEET 2 OF 4