HomeMy WebLinkAbout2492-1.tifcoo
SEWER IMPROVEMENT PLANS
SEWER IMPROVEMENTS NOTES: T__RAC T_ N
� e . I � 4 5 7 0 A�TD -14-570 -1 l�
1. NOTHING IN THESE PLANS RELIEVE THE CONTRACTOR FROM
OBTAINING PERMITS AS REQUIRED BY THE CITY.
2. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN
AN APPROXIMATE WAY ONLY. THE CONTRACTOR SHALL DETERMINE
THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE / o-
COMMENCING WORK. THE CONTRACTOR AGREES TO BE FULLY UNDERGROUND UTILITIES & STRUCTURES
d
RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT BE / �'�
OCCASIONED BY HIS FAILURE TO EXACTLY LOCATE AND PRESERVE ANY THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR
AND ALL UNDERGROUND UTILITIES. / STRUCTURES SHOWN IN THESE PLANS ARE OBTAINED BY A SEARCH OF
/ AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO
3. THE CONTRACTOR SHALL BE RESPONSIBLE F �s EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE
OR THE REMOVAL, y
REPLACEMENT OR RELOCATION OF ALL REGULATORY, WARNING AND q CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO Z
GUIDE SIGNS. OF I PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION a
OF, AND ANY DAMAGE TO THESE LINES OR STRUCTURES. Of o
4. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTSTRACT
U -U,
OR BENCH MARKS NOTED ON THE PLANS, OR FOUND DURING 14570-1 RESPONSIBLE CAUTION:
LIABLE FOR,I UNAUTHOR ZEDN C AINGESOOR USES OF ON Q
CONSTRUCTION. REMOVAL AND REPLACEMENT SHALL BE DONE BY A
/SHE THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND �
REGISTERED CIVIL ENGINEER, WITH RCE BELOW 33965, OR A LICENSED 10 I
LAND SURVEYOR ONLY. MUST BE APPROVED BY THE PREPARER OF THESE PLANS.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AN L!\ RECORD DRAWING
EFFECTIVE MEANS OF DUST CONTROL WHICH SHALL INCLUDE W SUMMIT AVENUE
PROVISIONS FOR ADEQUATE WATERING DURING THE CONSTRUCTION / S E The information on this drawing Ifi ohta,nod fFOM Q!bars and RANCHO
PROCESS. � mast he verified in tt►e fir ld t,,, .,f� �ri r .sn PRIVATE ENGINEER'S S NOTICE TO CONTRACTORS CO" NGA
>. prior t� 11,... or
W construction, HALL � F��`��',#ifs, INC. Is not responsit)ln for
6. ALL TRAVELED WAYS MUST BE CLEANED DAILY OF ALL DIRT, MUD AND underground faCifity (n���t�n,, Or C��.'i!:t10nS. All above-�rouncl THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE
DEBRIS DEPOSITED ON THEM AS A RESULT OF THE GRADING / Cl) ( facilities can be readily seen and verified by the nartiris that RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF
OPERATION. CLEANING IS TO BE DONE TO THE SATISFACTION OF THE intend to nsp �%a�Tan, s ar CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS
�'� j' AND PROPERTY: THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY
CITY ENGINEER OR ASSIGNEE. � '. r 9 VICINITY MAP
'�, AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE
7. CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE N.T.S.
CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF ', t ENGINEER HARMLESS FROM ANY AND ALL LIABILTY, REAL OR ALLEGED,
FONTANA ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK tlx: IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT
WITHIN THE CITY LIMITS. `V �a '�� 'Q
# EXCEPTING FOR LIABILITY ARISING FORM THE SOLE NEGLIGENCE OF THE
/'�
3 1 2
MH 16OWNER OR THE ENGINEER.
8. ALL STATIONING 0+00.00 REFERS TO THE CENTERLINE OF SEWER � \A
C1,_
•Tett 253.i•�" awkV V ., `
UNLESS NOTED OTHERWISE.
9. STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR
TO CONSTRUCT THE WORK TO THE PLAN GRADES.
10. ALL PIPELINE OR SUBSTRUCTURES OF ANY KIND AND ALL TELEPHONE
OR POWER POLES, WATER METERS, VALVES, HYDRANTS, IRRIGATION
STRUCTURES, ETC. SHOWN OR NOT SHOWN ON THIS PLAN AND
LOCATED WITHIN AREAS TO BE IMPROVED AND INTERFERING WITH
CONSTRUCTION, SHALL BE RELOCATED BY OTHERS. IT SHALL BE THE
CONTRACTOR'S RESPONSIBILITY TO NOTIFY ALL AGENCIES
CONCERNED BEFORE CONSTRUCTION BEGINS.
11. RECORD DRAWINGS SHALL BE PROVIDED TO THE CITY BY THE
ENGINEER OF RECORD.
12. REFER TO THE CITY OF FONTANA STD. DETAIL 131 FOR THE CITY OF
FONTANA STD. TRENCH REPAIR.
13. MANHOLE FRAMES AND COVERS TO BE CONSTRUCTED BY THE SEWER
CONTRACTOR 6" BELOW FINISHED SURFACE GRADE AND UPON
COMPLETION OF PAVING, CONTRACTOR SHALL RAISE SAME TO
FINISHED GRADE.
14. UNLESS OTHERWISE SPECIFIED, SANITARY SEWER LINES SHALL BE
CONSTRUCTED OF BELL AND SPIGOT TYPE VITRIFIED CLAY PIPE (V.C.P.).
VITRIFIED CLAY PIPE SHALL BE EXTRA STRENGTH CLASS AND SHALL
CONFORM TO THE PROVISIONS OF THE ASTM, DESIGNATION: C700-88
"STANDARD SPECIFICATIONS FOR VITRIFIED CLAY PIPE, EXTRA
STRENGTH, STANDARD STRENGTH, AND PERFORATED" AND TO THE
SPECIFICATIONS ENTITLED "VITRIFIED CLAY PIPE, MATERIALS SECTION"
PUBLISHED BY THE CLAY PIPE INSTITUTE. WHERE PROVISIONS OF
THESE SPECIFICATIONS ARE IN CONFLICT THE MORE RESTRICTIVE
PROVISION SHALL APPLY.
15. THE MANHOLES SHALL BE PRECAST ECCENTRIC CONCRETE MANHOLES
PER CITY OF FONTANA STANDARD DETAIL 112. CONCRETE FOR BASE
SLAB SHALL BE CLASS 560-B-3250. STANDARD MANHOLE FRAME AND
COVER AND REINFORCED CONCRETE COLLAR PER CITY OF FONTANA
STANDARD DETAIL 109.
16. EXCAVATION, PIPE LAYING AND JOINTING, BACKFILLING PAVEMENT
REMOVAL, REPLACEMENT AND TEST FOR LEAKAGE ARE PER CITY OF
FONTANA STANDARD SPECIAL PROVISIONS FOR SANITARY SEWER
CONSTRUCTION. VITRIFIED CLAY PIPE JOINTS SHALL CONFORM TO THE
PROVISIONS OF THE ASTM, DESIGNATION C425-86. PIPE INSTALLATION
SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION:
C12-86. ALSO, SEE CITY OF FONTANA STANDARD DETAIL 131
"STANDARD TRENCH REPAIR".
17. ELEVATIONS SHOWN ON PROFILE AS "TOP OF MANHOLE" ARE
APPROXIMATE ONLY AND NOT TO BE USED FOR SETTING OF MANHOLE
RING.
18. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS, THE
CITY OF FONTANA PUBLIC WORKS DEPARTMENT STANDARD PLANS,
AND STANDARD SPECIFICATIONS FOR PUBLIC WORK CONSTRUCTION,
LATEST EDITION.
19. SHORT STUBS WITH FLEXIBLE COMPRESSION JOINTS SHOULD BE USED
AT THE MANHOLE WALLS TO ABSORB MINIMAL DEFLECTION.
20. SEWER CONTRACTORS SHALL CHISEL "X" IN THE CURB AT THE
LOCATION OF ALL LATERALS.
21. THE CONTRACTOR SHALL PROVIDE THE TERMINAL CLEANOUT AT THE
END OF THE BOUNDARY IF THE SEWER CONSTRUCTION WILL BE DONE
IN SEVERAL PHASES. SEE THE CITY OF FONTANA STANDARD DETAIL
128 FOR SEWER TERMINAL CLEANOUT.
22 ALL 4" HOUSE LATERALS SHALL BE INSTALLED ON A 2% MINIMUM
GRADE, UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER.
EX. GROUND OR -
PROP. SUBGRADE
3" MAX. SIZE NATIVE'
SOIL, COMPACTED 95%
6" MAX. SIZE NATIVE --
SOIL, COMPACTED 90%
6" MIN.
10 MAX.
SELECTED NATIVE SOIL
PER CITY PLANS & SPECS.
TRACT 14570
NOTES:
1. PAVEMENT BREAKING AND REPLACEMENT SHALL BE IN
ACCORDANCE WITH REQUIREMENTS OF THE CITY OF FONTANA
STD. #131.
;:..: 2. COMPACTION TEST MAY BE REQUIRED AT THE DISCRETION
- OF THE CITY INSPECTOR, AND AT NO EXPENSE TO THE CITY.
N
--8" V.C.P. SEWER BEDDING MATERIAL SHALL BE SAND, GRAVEL,
�� CRUSHED AGGREGATE, OR NATIVE FREE -DRAINING
-1- GRANULAR MATERIAL HAVING A SAND EQUIVALENT
OF NOT LESS THAN 30, AND SHALL HAVE A
PERCENTAGE COMPOSITION BY WEIGHT WHICH
CONFORMS TO THE FOLLOWING GRADING:
SIEVE ANALYSIS - PERCENT PASSING
NOMINAL SIZE
1-1/2 pf
1"
3/4"
1/2
3/8"
NO. 4
NO. 8
NO. 16
3/4" TO NO. 4
-
100
90 TO 100
-
20 TO 55
0 TO 10
0 TO 5
-
TYPICAL BEDDING FOR SEWER V.C.P.
N.T.S.
Underground Service Alert
Call: TOLL FREE
1-800
422-4133
TWO WORKING DAYS
BEFORE YOU DIG
Q�OFESS/�N�
c ~ N6.35275 Z �'
* Exp.9/30/99
CiVI
r�F CA1.�F
CONSTRUCTION SITE
BENCHMARK: ELEV. 1534.50
SET CHIS SQUARE ON CATCH BASIN
AT THE N.W. CURB RETURN
BRIDLEPATH DR. & CHERRY AVE.
50 FT. N.E. C/L BRIDLEPATH DR.
36 FT. N.W. C/L CHERRY AVE.
BENCHMARK: ELEV. 1313.04
FWE 43 - RAILROAD SPIKE IN E.P. BY
PP#1536663E S'LY. SIDE OF BASELINE
220' E'LY. OF CHERRY AVE.
BASIS OF BEARINGS:
THE NORTH LINE OF THE NORTHWEST ONE
HALF OF SECTION 23, TOWNSHIP 1 NORTH,
RANGE 6 WEST, S.B.M. BEING N89'50'00"E
PER TRACT NO. 13750 RECORDED IN BOOK
250, PAGES 48 THROUGH 66 OF MAPS,
RECORDS OF SAN BERNARDINO COUNTY.
LEGAL DESCRIPTION:
LOT 14 OF TRACT NO. 13750 IN THE CITY
OF FONTANA, COUNTY OF SAN BERNARDINO,
CALIFORNIA, PER AMENDING MAP RECORDED
BOOK 2.50, PAGES 48 TO 66, INCLUSIVE,
RECORDS OF SAN BERNARDINO COUNTY.
UTILITY PURVEYORS:
ELECTRICITY
SOUTHERN CALIFORNIA EDISON CO.
DISTRIBUTION PLANNING
7951 REDWOOD AVENUE
FONTANA, CA 92336
(909) 357-6562
CONTACT: ARMANDO GONZALES
GAS
SOUTHERN CALIFORNIA GAS CO.
DISTRIBUTION PLANNING
16231 VALLEY BOULEVARD
FONTANA, CA 92335
(909) 428-8402
CONTACT: DAVID PADILLA
WATER
FONTANA WATER COMPANY
7440 NUEVO AVENUE
FONTANA, CA 92335
(909) 822-2201
91MAM
CITY OF FONTANA
8353 SIERRA AVENUE
P.O. BOX 518
FONTANA, CA 92335
(909) 350-7610
OWNER/DEVELOPER
ALPER DEVELOPMENT
6101 CHERRY AVENUE
FONTANA, CA 92336
(909) 899-0156
CONTACT: CRAIG SWARTS
COMCAST CABLEVISION
1205 DUPONT STREET
ONTARIO, CA 91761
(909) 988-8322 X3055
CONTACT: JACK HAYES
CONSTRUCTION NOTES & QUANTITIES:
.00ATION
MARKS CABLEVISION
FIBER -OPTICS/ TRUNK LINK THROUGH PROJECT
4240 HALLMARK PARKWAY
SAN BERNARDINO, CA 92407
(909) 880-0220
CONTACT: JOE DEARMAN
GTE CALIFORNIA, INC.
CAB20VF
870 NORTH MOUNTAIN AVENUE
UPLAND, CA 91786
(909) 931-2472
CONTACT: DANIEL TUCKER
WI LTEL, INC -
FIBER -OPTIC TELECOMMUNICATIONS
LAS VEGAS, NEVADA TO LOS ANGELES, CA
UPLAND, CA 91786
P.O. BOX 21348, MD 26-3
TULSA, OK 74121
918) 588-3397
909) 947-9441 (LOCAL CONTACT)
LOCAL CONTACT: JERRY KENNEDY
S
O
�Ln
no
N r-,
L6
h�
QUANTITY
ITEM
DESCRIPTION
UNIT
TRACT NO.
TRACT NO.
14570
14570-1
OCONSTRUCT
8" EXTRA STRENGTH VCP SEWER LINE, BEDDING PER
3,054
2,798
LF
DETAIL ON SHEET 1.
OCONSTRUCT
48" DIA. ECCENTRIC MANHOLE PER CITY OF FONTANA
12
8
EA
STD. NO. 112.
CONSTRUCT 4" SEWER LATERAL AND HOUSE CLEANOUT PER CITY
3
OF FONTANA STD. NO. 125 AND INSTALL SEWER CLEAN-OUT BOX PER
2775
2325
LF
CITY OF FONTANA STD. NO. 125A (IN CONCRETE AREAS) OR 125B (IN
LANDSCAPE AREAS)
CONSTRUCT TEMPORARY TERMINAL CLEANOUT AT PHASE BOUNDARY
PER CITY OF FONTANA STD. NO. 128., - 1 EA
In 1x0_. "wl N G
5, G d
- -- J-
! l CL. tAUc)wL64=7rnA1 . A2. _ OdTE
S
O
�Ln
no
N r-,
L6
h�