HomeMy WebLinkAbout2487-1.tifGENERAL NOTES FOR SEWER SYSTEM
1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS. THE
CITY OF FONTANA PUBLIC WORKS DEPARTMENT STANDARD SPECIFICATIONS
DATED 1975 INCLUDING LATEST REVISIONS, AND STANDARD
SPECIFICATIONS FOR PUBLIC WORK CONSTRUCTION, 1994 EDITION.
2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF
FONTANA ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK
WITHIN THE CITY LIMITS.
3. UNLESS OTHERWISE SPECIFIED, SANITARY SEWER LINES SHALL
BE CONSTRUCTED OF BELL AND SPIGOT TYPE VITRIFIED CLAY
PIPE (V.C.P.). VITRIFIED CLAY PIPE SHALL BE EXTRA
STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF
THE ASTM, DESIGNATION: C700-89 "STANDARD SPECIFICATION
FOR VITRIFIED CLAY PIPE. EXTRA STRENGTH STANDARD STRENGTH,
AND PERFORATED" AND TO THE SPECIFICATIONS ENTITLED "VITRIFIED
CLAY PIPE, MATERIALS SECTION" PUBLISHED BY THE CLAY PIPE
INSTITUTE. WHERE PROVISIONS OF THESE SPECIFICATIONS ARE IN
CONFLICT THE MORE RESTRICTIVE PROVISION SHALL APPLY.
4. THE MANHOLES SHALL BE PRECAST CONCRETE MANHOLES PER CITY
OF FONTANA STANDARD DETAIL 112. CONCRETE FOR BASE SLAB
SHALL BE CLASS 560-B-3250. STANDARD MANHOLE FRAME AND
COVER AND REINFORCED CONCRETE COLLAR -PER CITY OF
FONTANA STANDARD DETAIL 109.
5. ALL STATIONING REFERS TO CENTERLINE SEWER, UNLESS OTHERWISE NOTED.
6. ELEVATIONS SHOWN ON PROFILE AS "TOP OF MANHOLE' ARE APPROXIMATE
ONLY AND NOT TO BE USED FOR SETTING OF MANHOLE RING.
7. MANHOLE FRAMES AND COVERS TO BE CONSTRUCTED BY THE SEWER
CONTRACTOR 6" BELOW FINISHED SURFACE GRADE AND UPON COMPLETION
OF PAVING, THE PAVING CONTRACTOR SHALL RAISE SAME TO FINISHED
GRADE.
8. SHORT STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE
USED AT THE MANHOLE WALLS TO ABSORB MINIMAL DEFLECTION.
9. 4' V.C.P. HOUSE SEWER LATERALS AND LATERAL HOUSE CLEANOUT -
PER CITY OF FONTANA STANDARD DETAIL 125.
TERMINATE ALL HOUSE SEWER LATERALS 3' INSIDE THE PROPERTY LINE
(OR PUBLIC UTILITY EASEMENT) WITH A PLUG, PER STANDARD.
10. ADEQUATE STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE
CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES.
11. ALL PIPELINES OR SUBSTRUCTURES OF ANY KIND AND ALL TELEPHONE
OR POWER POLES, WATER METERS, VALVES, HYDRANTS, IRRIGATION
STRUCTURES ETC..., SHOWN ON THESE PLANS OR NOT, WITHIN AREA TO
BE IMPROVED AND INTERFERING WITH CONSTRUCTION, SHALL BE
RELOCATED BY OTHERS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY
TO NOTIFY ALL AGENCIES CONCERNED BEFORE CONSTRUCTION BEGINS.
12. "AS BUILT" PLANS SHALL BE PROVIDED TO THE ENGINEER OF RECORD BY THE
CONTRACTOR. THE ENGINEER OF RECORD SHALL PROVIDE it RECORD DRAWINGS "
TO THE CITY PRIOR TO CITY ACCEPTANCE OF THE SEWER SYSTEM.
13. SEWER CONTRACTOR SHALL CHISEL "X" IN THE CURB AT THE LOCATION
OF ALL LATERALS.
14. THE CONTRACTOR SHALL PROVIDE THE TERMINAL CLEANOUT AT THE
END OF THE BOUNDARY IF THE SEWER CONSTRUCTION WILL BE DONE
IN SEVERAL PHASES. SEE DETAIL ON THIS SHEET AND CITY OF
FONTANA STANDARD DETAIL 128 FOR SEWER TERMINAL CLEANOUT.
15. ALL 4' HOUSE SEWER LATERAL SHALL BE INSTALLED ON A 2% MINIMUM GRADE
UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER.
16. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AN EFFECTIVE MEANS OF
Underground Service Alert
FOR
o r Call: TOLL FREE
y �
1-800
422-4133
TWO WORKING DAYS BEFORE YOU DIG
TABLE: 200-1.2(A)
SIEVE SIZE
DUST CONTROL WHICH SHALL INCLUDE PROVISION FOR ADEQUATE WATERING DURING
1 1/2 to
THE GRADING PROCESS AND PROVISIONS FOR CONTINUANCE OF DUST CONTROL AFTER
1"
THE GRADING UNTIL SUCH TIME THAT THE GRADED SURFACE PRESENTS EFFICIENT
3/4'
PROTECTIVE COVER AGAINST WIND OR WATER EROSION THAT SPECIAL DUST CONTROL
1/21'
MEASURES ARE NO LONGER NECESSARY.
3/8"
17.
THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS OR BENCH
0-15
MARKS NOTED ON THE PLANS OR FOUND DURING CONSTRUCTION WITHOUT PRIOR
0-5
NOTIFICATION TO THE CIVIL ENGINEER. REMOVAL AND REPLACEMENT SHALL BE
B
DONE BY A REGISTERED CIVIL ENGINEER
OR LICENSED LAND SURVEYOR. SURVEY
MONUMENTS WHICH WILL BE DESTROYED
AS A RESULT OF THIS CONSTRUCTION
SHALL BE REPLACED. CONTRACTOR SHALL NOTIFY REGISTERED CIVIL ENGINEER OR
LICENSED LAND SURVEYOR ONE WEEK PRIOR
TO CONSTRUCTION SO THAT TIES TO
MONUMENTS CAN BE ESTABLISHED FOR
LATER REPLACEMENT OF SAID MONUMENTS
BY SAID REGISTERED CIVIL ENGINEER OR
LICENSED LAND SURVEYOR.
18.
City of Fontana, utility notification list
City of Fontana
Pacific Bell Co.
Attn: Carlos Navarro
Attn: Virginia Becker
8353 Sierra Avenue
3939 E. Coronado Street
Fontana, CA. 92335
Anaheim, CA. 92807
(909) 350-6632
(714) 666-5467
So. Calif. Gas Company
Underground Service Alert
Attn: Dennis Freeman
(800) 422-4133
1981 W. Lugonia Avenue
Redlands, CA. 92374
Comcast ( Cable TV )
(909) 335-7547
Attn: Jack Hayes
Emergencies: (800) 427-2200
1205 Dupont Ave.
Ontario, CA. 91761
So. Calif. Edison Company
(909) 390-4738
300 N. Pepper Avenue
Rialto, CA. 92376
General Telephone Company
909 820-5598 – Underground
Attn: Steve Hock
909 875-5100 – Transmission
1400 E. Phillips Blvd.
213 637-1233 – Pipelines
Ontario, CA. 91766
909 357-6223 – Distribution
(800) 422-4133
800 422-4133
Fontana Water Company
Crawford Canyon Mutual Water Co.
Attn: Michael J. McGraw
Attn: Bill Vanderkieft, Jr.
8440 Nuevo Avenue
(619) 868-6040
Fontana CA. 92235
(909) 822-2201
Fax: (909) 823-5046
19.
THE WALLS AND C2ES-OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN
DEPTH SHALL BE EFFECTIVELY GUARDED
BY A SHORING SYSTEM, SLOPING OF THE
GROUND OR OTHER EQUIVALENT MEANS.
TRENCHES LESS THAN FIVE (5) FEET IN
DEPTH SHALL ALSO BE GAURDED WHEN
EXAMINATION INDICATES HAZARDOUS GROUND
MOVEMENT MAY BE EXPECTED.
20.
THE CONTRACTOR(S) SHALL ALSO OBTAIN A PERMIT TO PERFORM EXCAVATION OR
TRENCH WORK AS DESCRIBED IN NOTE
19 ABOVE FROM CAL/OHSA.
Underground Service Alert
FOR
o r Call: TOLL FREE
y �
1-800
422-4133
TWO WORKING DAYS BEFORE YOU DIG
TABLE: 200-1.2(A)
SIEVE SIZE
PERCENTAGE
PASSING SIEVES
1 1/2 to
–
1"
–
3/4'
100
1/21'
90-100
3/8"
20-60
N0.4
0-15
N0,8
0-5
ASTM C 131
TEST GRADING
B
w
w
0
w
CITY OF FONTANA
SEWER IMPROVEMENT PLANS
TRACT NO. 15655-7, 10 and 11
EXISTING
HIGHLAND
AVENUE
3" MAX SIZE NATIVE
SOIL, COMPACTED 95%
6" MIN.
10" MAX.
- —� � i—iii—i i �—I —
��II N
6" MAX SIZE NATIVE
SOIL, COMPACTED 90%
1/2" CRUSHED
STONE BEDDING
PER STD. SPECS.
FOR PUBLIC WORKS
CONSTRUCTION
TABLE 200-1.2(A)
SHOWN BELOW
INDEX MAP
SCALE: 1"=40Y
6" MIN. 3" MAX SIZE NATIVE
10" MAX. SOIL, COMPACTED 95%
6„ MIN.
_I� :: 10" MAX.
�—i71—
MAX
SIZE NATIVE -�N
SOIL, COMPACTED 90�
1" MAX. SIZE SELECTED '
NATIVE BEDDING COMPACTED
TO 90%
01
;.,
IT -17 i I—iii —ii1- »
8 VCP
8" VCP -/ I -d-
TYPICAL BEDDING FOR 8" VCP
10' OR DEEPER
SCALE: 1" = 2'
21. DUCTILE IRON PIPE SHALL BE ASPHALT LINED AND COATED, BELL AND SPIGOT OR
MECHANICAL JOINT AND SHALL CONFORM TO SECTION 207-9 OF STANDARD
SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, 1994 EDITION.
22. CONNECTION BETWEEN EXISTING VCP AND PROPOSED DUCTILE IRON PIPE SHALL BE
TYPE 'Z' JOINT AND SHALL CONFORM TO SECTION 208-5 OF STANDARD
SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, 1994 EDITION.
6" MIN.
10" MAX.
- SEE SHEET 2
- SEE SHEET 5
- SEE SHEET 7
- SEE SHEET 6
- SEE SHEET 3
;ET 2
1" MAX. SIZE SELECTED
NATIVE BEDDING COMPACTED
TO 90%
N z
TYPICAL BEDDING FOR 8" VCP
LESS THAN 10' DEEP
SCALE: 1" = 2'
CONSTRUC110N NOTES
(D -- CONSTRUCT 8" VCP SEWER 4,090 L. F.
3a—CONSTRUCT PRECAST CONCRETE MANHOLE PER CITY STD. DWG. NO. 112 13 EA.
O4 — CONSTRUCT 4' VCP SEWER LATERAL PER CITY STD. DWG. NO. 125 127 EA.
INSTALL 8" VCP STOPPER 1 EA.
O8 -- REMOVE PLUG & JOIN EXISTING 8" VCP SEWER 1 EA.
13 CONSTRUCT 8" DUCTILE IRON SEWER, CLASS 52 100 L.F.
(See general note 21 & 22)
NOTE: CONSTRUCT NOTE NO. 1,5 ,7, & 9-12 NOT USED ON THESE PLANS
VICINITY MAP
SCALE: 1"= 1/2 mile
PoeA WIA1
Filename: L:\DWG\10201\15655-7\10201S1.DWG
Date: May 22, 1997