HomeMy WebLinkAbout2465-1GENERAL NOTES 1. THE CONSTRUCTION OF ALL PUBLIC IMPROVEMENTS SHALL CONFORM TO THESE PLANS AND TO THE REQUIREMENTS OF THE CITY STANDARD SPECIFICATIONS, PUBLIC WORKS DEPARTMENT, CITY OF FONTANA AND STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (GREEN BOOK), LATEST EDITION. 2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM FONTANA ENGINEERING DIVISION PRIOR TO START OF ANY WORK WITHIN THE CITY LIMITS. ALL INSPECTIONS SHALL BE REQUESTED THROUGH THE CITY OF FONTANA ENGINEERING DIVISION AT LEAST 24 HOURS PRIOR TO THE START OF ANY WORK AT (909) 350-6632. 3. STATIONING REFERS TO THE CENTERLINES OF STORM DRAINS EXCEPT WHERE OTHERWISE NOTED. 4. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO ALL ADJOINING CURBS AND SIDEWALKS. 5. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAS BEEN PLACED, INSPECTED AND APPROVED. 6. ALL UNDERGROUND WORK SHALL BE COMPLETED PRIOR TO PAVING OF STREETS. 7. EXISTING UNDERGROUND UTILITIES ARE AS PER THE AVAILABLE RECORDS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE ACTUAL LOCATION AND ELEVATION IN THE FIELD. 8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE EFFECTIVELY GUARDED BY A SHORING SYSTEM, SLOPING OF THE GROUND OR OTHER EQUIVALENT MEANS. TRENCHES LESS THAN FIVE (5) FEET IN DEPTH SHALL ALSO BE GUARDED WHEN EXAMINATION INDICATES HAZARDOUS GROUND MOVEMENT MAY BE EXPECTED. 9. THE CONTRACTOR(S) SHALL ALSO OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK AS DESCRIBED IN NOTE 8 ABOVE FROM CAL/OSHA. 10. ALL MANHOLES SHALL BE CONSTRUCTED 6" BELOW PAVEMENT GRADE AND BROUGHT TO FINISHED GRADE BY THE PAVING CONTRACTOR AFTER PAVEMENT IS IN PLACE. 11. IMMEDIATELY FOLLOWING REMOVAL OF EXISTING PAVEMENT OR DIKE OR CURB AND/OR GUTTER THE CONTRACTOR SHALL DILIGENTLY PURSUE THAT PORTION OF THE WORK TO COMPLETION. 12. ALL C.M.P. INSTALLATIONS AND CONNECTIONS SHALL BE MADE PER MANUFACTURER'S SUGGESTED METHOD UNLESS OTHERWISE SPECIFIED ON THE PLANS. 13. IF DURING CONSTRUCTION, GROUND WATER IS ENCOUNTERED, A SYSTEM APPROVED BY THE CITY ENGINEER SHALL BE INSTALLED TO DEWATER SAID AREA AT THE DIRECTION OF THE SOILS ENGINEER. 14. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY'S INSPECTOR. 15. ALL EXPOSED METAL SURFACES SHALL BE GALVANIZED IN ACCORDANCE WITH THE CITY STANDARD SPECIFICATIONS. 16. "AS—BUILT" PLANS SHALL BE PROVIDED TO THE ENGINEER OF RECORD, BY THE CONTRACTOR. THE ENGINEER OF RECORD SHALL PROVIDE "RECORD DRAWING" TO THE CITY PRIOR TO CITY ACCEPTANCE OF THE STORM DRAIN SYSTEM. 0 CITY OF FONTANA STORM DRAIN IMPROVEMENT PLANS C 5 LL FOR TRACT NO. 15655-5 and 6 1 MX MAP , SCALE: 1 =400 CONSTRMTlON NOTES ELATE OF OUANT111ES 1� CONSTRUCT 18" DIA. REINFORCED CONCRETE PIPE 2� CONSTRUCT 24" DIA. REINFORCED CONCRETE PIPE 3� CONSTRUCT 30" DIA. REINFORCED CONCRETE PIPE 10 CONSTRUCT MANHOLE PER APWA STD. PLAN 321-0 13 CONSTRUCT TIMBER BULKHEAD PER DETAIL HEREON 75 CONSTRUCT CATCH BASIN PER APWA STD. PLAN 300-1, W=7' 76 CONSTRUCT CATCH BASIN PER APWA STD. PLAN 300-1, W=10' 22 REMOVE TIMBER BULKHEAD AND JOIN EXISTING RCP NOTE CONSTRUCTION NOTES 4-9, 11,12, 17-21, NOT USED ON THESE PLANS. 233 L.F. 90 L.F. 372 L.F. 3 EA. 1 EA. 4 EA. 1 EA. 2 EA. Filename: L:\DWG\10201\15655-5\SDRAINI.DWC Date: January 17, 1997 3" MAX SIZE NATIVE 17. City of Fontana, utility notification list SOIL, COMPACTED 959,E 6 " 6 " e c City of Fontana Pacific Bell Co. "MIN. 10 MAX. "MIN. 0 MAX. � Attn: Carlos Navarro Attn: Virginia Becker 00000 8353 Sierra Avenue 3939 E. Coronado Street — — — 'g Fontana, CA. 92335 Anaheim, CA. 92807 N (909) 350-6632 (714) 666-5467 �- So. Calif. Gas Company Underground Service Alert 6" MAX SIZE NATIVE PROPOSED STORM Attn: Dennis Freeman (800) 422-4133 SOIL, COMPACTED 90% DRAIN PIPE Baseline 1981 W. Lugonia Avenue 1" MAX. SIZE SELECTED Redlands, CA. 92374 (909) 335-7547 Comcast ( Cable TV) Attn: Jack Hayes NATIVE BEDDING COMPACTED Emergencies: (800) 427-2200 1205 Dupont Ave. TO 90% .. So. Calif. Edison Company Ontario, CA. 91761" (909) 390-4738 :�' •'`• •�=•s "' 3 x 12 x(D+2t) 300 N. Pepper Avenue •..;:• _�.. "=Z':i :'y�H �`• .. N ? Rialto, CA. 92376 General Telephone Company A 909 820-5598 — Underground Attn: Steve Hock o 909 875-5100 — Transmission 1400 E. Phillips Blvd. •A' + ";`' w CL o o -o E m 213 637-1233 — Pipelines Ontario, CA. 91766 _..:, a p U 909 357-6223 — Distribution (800) 422-4133 CUT 3"x12" FOR $ 800 422-4133 _ '`• TIGHT FIT (1 REQ'D) Fontana Water Company Foothill Crawford Canyon Mutual Water Co. Attn: Michael J. McGraw PROPOSED RCP Attn: Bill Vanderkieft, Jr. 8440 Nuevo Avenue STORM DRAIN �• (619) 868-6040 Fontana CA. 92235 3"x12"x(D+2t) (909) 822-2201 Fax: (909) 823-5046 TYPICAL BEDEM FOR RCP UMBER BULJCHEAD DETAL WOMN MAP 19. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN STORM DRAiNNOT TO SCALE SCALE: 1"= 1/2 mile DEPTH SHALL BE EFFECTIVELY GUARDED BY A SHORING SYSTEM, SLOPING OF THE NOT TO SCALE GROUND OR OTHER EQUIVALENT MEANS. TRENCHES LESS THAN FIVE (5) FEET IN DEPTH SHALL ALSO BE GAURDED WHEN EXAMINATION INDICATES HAZARDOUS GROUND MOVEMENT MAY BE EXPECTED. 20. THE CONTRACTOR(S) SHALL ALSO OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK AS DESCRIBED IN NOTE 19 ABOVE FROM CAL/OHSA. Filename: L:\DWG\10201\15655-5\SDRAINI.DWC Date: January 17, 1997