HomeMy WebLinkAbout2455-1SEWER IMPROVEMENTS NOTES:
1. NOTHING IN THESE PLANS RELIEVE THE CONTRACTOR FROM
OBTAINING PERMITS AS REQUIRED BY THE CITY.
2. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN
AN APPROXIMATE WAY ONLY. THE CONTRACTOR SHALL DETERMINE
THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE
COMMENCING WORK. THE CONTRACTOR AGREES TO BE FULLY
RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT BE
OCCASIONED BY HIS FAILURE TO EXACTLY LOCATE AND PRESERVE ANY
AND ALL UNDERGROUND UTILITIES.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL,
REPLACEMENT OR RELOCATION OF ALL REGULATORY, WARNING AND
GUIDE SIGNS.
4. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS
OR BENCH MARKS NOTED ON THE PLANS, OR FOUND DURING
CONSTRUCTION. REMOVAL AND REPLACEMENT SHALL BE DONE BY A
REGISTERED CIVIL ENGINEER, WITH RCE BELOW 33965, OR A LICENSED
LAND SURVEYOR ONLY.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AN
EFFECTIVE MEANS OF DUST CONTROL WHICH SHALL INCLUDE
PROVISIONS FOR ADEQUATE WATERING DURING THE CONSTRUCTION
PROCESS.
6. ALL TRAVELED WAYS MUST BE CLEANED DAILY OF ALL DIRT, MUD AND
DEBRIS DEPOSITED ON THEM AS A RESULT OF THE GRADING
OPERATION. CLEANING IS TO BE DONE TO THE SATISFACTION OF THE
CITY ENGINEER OR ASSIGNEE.
7. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF
FONTANA ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK
WITHIN THE CITY LIMITS.
S. ALL STATIONING 10+00.W REFERS TO THE CENTERLINE OF SEWER,
UNLESS NOTED OTHERWISE.
9. STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR
TO CONSTRUCT THE WORK TO THE PLAN GRADES.
10. ALL PIPELINE OR SUBSTRUCTURES OF ANY KIND AND ALL TELEPHONE
OR POWER POLES, WATER METERS, VALVES, HYDRANTS, IRRIGATION
STRUCTURES, ETC. SHOWN OR NOT SHOWN ON THIS PLAN AND
LOCATED WITHIN AREAS TO BE IMPROVED AND INTERFERING WITH
CONSTRUCTION, SHALL BE RELOCATED BY OTHERS. IT SHALL BE THE
CONTRACTOR'S RESPONSIBILITY TO NOTIFY ALL AGENCIES
CONCERNED BEFORE CONSTRUCTION BEGINS.
11. RECORD DRAWINGS SHALL BE PROVIDED TO THE CITY BY THE
ENGINEER OF RECORD.
12. REFER TO THE CITY OF FONTANA STD. DETAIL 131 FOR THE CITY OF
FONTANA STD. TRENCH REPAIR.
13. MANHOLE FRAMES AND COVERS TO BE CONSTRUCTED BY THE SEWER
CONTRACTOR 6" BELOW FINISHED SURFACE GRADE AND UPON
COMPLETION OF PAVING, CONTRACTOR SHALL RAISE SAME TO
FINISHED GRADE.
14. UNLESS OTHERWISE SPECIFlED, SANITARY SEWER LINES SHALL BE
CONSTRUCTED OF BELL AND SPIGOT TYPE VITRIFIED CLAY PIPE (V.C.P.).
VITRIFIED CLAY PIPE SHALL BE EXTRA STRENGTH CLASS AND SHALL.
CONFORM TO THE PROVISIONS OF THE ASTM, DESIGNATION: C700-88
"STANDARD SPECIFICATIONS FOR VITRIFIED CLAY PIPE, EXTRA
STRENGTH, STANDARD STRENGTH, AND PERFORATED" AND TO THE
SPECIFICATIONS ENTITLED "VITRIFIED CLAY PIPE, MATERIALS SECTION"
PUBLISHED BY THE CLAY PIPE INSTITUTE. WHERE PROVISIONS OF
THESE SPECIFICATIONS ARE IN CONFLICT THE MORE RESTRICTIVE
PROVISION SHALL APPLY.
15. THE MANHOLES SHALL BE PRECAST ECCENTRIC CONCRETE MANHOLES
PER CITY OF FONTANA STANDARD DETAIL 112. CONCRETE FOR BASE
SLAB SHALL BE CLASS 560-B-3250. STANDARD MANHOLE FRAME AND
COVER AND REINFORCED CONCRETE COLLAR PER CITY OF FONTANA
STANDARD DETAIL 109.
16. EXCAVATION, PIPE LAYING AND JOINTING, BACKFILLING PAVEMENT
REMOVAL, REPLACEMENT AND TEST FOR LEAKAGE ARE PER CITY OF
FONTANA STANDARD SPECIAL PROVISIONS FOR SANITARY SEWER
CONSTRUCTION. VITRIFIED CLAY PIPE JOINTS SHALL CONFORM TO THE
PROVISIONS OF THE ASTM, DESIGNATION C425-86. PIPE INSTALLATION
SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION -
C12 -86. ALSO, SEE CITY OF FONTANA STANDARD DETAIL 131
"STANDARD TRENCH REPAIR".
17. ELEVATIONS SHOWN ON PROFILE AS "TOP OF MANHOLE" ARE
APPROXIMATE ONLY AND NOT TO BE USED FOR SETTING OF MANHOLE
RING.
18. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS, THE
CITY OF FONTANA PUBLIC WORKS DEPARTMENT STANDARD PLANS,
AND STANDARD SPECIFICATIONS FOR PUBLIC WORK CONSTRUCTION,
LATEST EDITION.
19. SHORT STUBS WITH FLEXIBLE COMPRESSION JOINTS SHOULD BE USED
AT THE MANHOLE WALLS TO ABSORB MINIMAL DEFLECTION.
20. SEWER CONTRACTORS SHALL CHISEL "X" IN THE CURB AT THE
LOCATION OF ALL LATERALS.
21. THE CONTRACTOR SHALL PROVIDE THE TERMINAL CLEANOUT AT THE
END OF THE BOUNDARY IF THE SEWER CONSTRUCTION WILL BE DONE
IN SEVERAL PHASES. SEE THE CITY OF FONTANA STANDARD DETAIL
128 FOR SEWER TERMINAL CLEANOUT.
22 ALL 4" HOUSE LATERALS SHALL BE INSTALLED ON A 2% MINIMUM
GRADE, UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER.
HUNTER'S RIDGE
SEWER IMPROVEMENT PLANS
_1_sLFji1m@ I
i 11Luill
14573- 1
o009X•
INDEX MA
SCALE: 1"=1 50
EX. GROUND OR
PROP. SUBGRADE
3" MAX. SIZE NATIVr NOTES:
SOIL, COMPACTED 95
1. PAVEMENT BREAKING AND REPLACEMENT SHALL BE IN
ACCORDANCE WITH REQUIREMENTS OF THE CITY OF FONTANA
6" MAX. SIZE NATIVE STD. #131.
SOIL, COMPACTED 90%
:.:.: 2. COMPACTION TEST MAY BE REQUIRED AT THE DISCRETION
OF THE CITY INSPECTOR, AND AT NO EXPENSE TO THE CITY.
6" MIN. N
Ir -
10" MAX.
8" V.C.P. SEWER BEDDING MATERIAL SHALL BE SAND, GRAVEL,
SELECTED NATIVE SOIL + CRUSHED AGGREGATE, OR NATIVE FREE -DRAINING
PER CITY PLANS do SPECS. GRANULAR MATERIAL HAVING A SAND EQUIVALENT
OF NOT LESS THAN 30, AND SHALL HAVE A
PERCENTAGE COMPOSITION BY WEIGHT WHICH
CONFORMS TO THE FOLLOWING GRADING:
NOMINAL SIZE
1-1 /2"
1"
3/4"
1/2"
3/8"
NO. 4
NO. 8
NO. 16
3/4" TO NO. 4
-
100
90 TO 100
-
20 TO 55
0 T010
0 TO 5
-
TYPICAL BEDDING FOR SEWER V.C.P.
N.T.S.
Underground Servlce Alert
Call: TOLL FREE
1 -Boo
422-4133
TW woRrcDA"
BEFORE YOU DIG
IDDRAVANGS &
CONSTRUCTION SITE
BENCHMARK: ELEV. 1534.50
SET CHIS SQUARE ON CATCH BASIN
AT THE N.W. CURB RETURN
BRIDLEPATH DR. do CHERRY AVE.
50 FT. N. E. CABRIDLEPATH DR.
36 FT. N. W. C/L CHERRY AVE.
BENCHMARK: ELEV. 1313.04
FWE 43 - RAILROAD SPIKE IN E.P. BY
PP#1536663E S'LY. SIDE OF BASELINE
220' E'LY. OF CHERRY AVE.
ASIS OF BEARINGS:
UNDERGROUND UTILITIES & STRUCTURES
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR
STRUCTURES SHOWN IN THESE PLANS ARE OBTAINED BY A SEARCH OF
AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO
EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE
CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO
PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION
OF, AND ANY DAMAGE TO THESE LINES OR STRUCTURES.
"CAUTION: THE ENGINEER PREPARING THESE PLANS WALL NOT BE
RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF
THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND
MUST BE APPROVED BY THE PREPARER OF THESE PLANS."
PRIVATE ENGINEER'S NOTICE TO CONTRACTORS
THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE
RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF
CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS
AND PROPERTY: THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY
AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE
CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE
ENGINEER HARMLESS FROM ANY AND ALL LIABILTY, REAL OR ALLEGED,
IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT,
EXCEPTING FOR LIABILITY ARISING FORM THE SOLE NEGLIGENCE OF THE
OWNER OR THE ENGINEER.
THE NORTH LINE OF THE NORTHWEST ONE
HALF OF SECTION 23, TOWNSHIP 1 NORTH,
RANGE 6 WEST, S.B.M. BEING N89'50'00"E
PER TRACT NO. 13750 RECORDED IN BOOK
250, PAGES 48 THROUGH 66 OF MAPS,
RECORDS OF SAN BERNARDINO COUNTY.
AL DESCRIPTION:
LOTS 1 - 50 OF TRACT NO. 14573-1, IN
THE CITY OF FONTANA, COUNTY OF SAN
BERNARDINO, CALIFORNIA, PER MAP
RECORDED IN BOOK , PAGES TO ,
RECORDS OF SAN BERNARDINO COUNTY.
UTILITY PURVEYORS:
�ELECTRICITY
SOUTHERN CALIFORNIA EDISON CO.
DISTRIBUTION PLANNING
7951 REDWOOD AVENUE
FONTANA, CA 92336
(909) 357-6562
CONTACT: ARMANDO GONZALES
SOUTHERN CALIFORNIA GAS CO.
DISTRIBUTION PLANNING
16231 VALLEY BOULEVARD
FONTANA, CA 92335
(909) 428-8402
CONTACT: DAVID PADILLA
,WATER
FONTANA WATER COMPANY
8440 NUEVO AVENUE
FONTANA, CA 92335
(909) 822-2201
CITY OF FONTANA
8353 SIERRA AVENUE
P.O. BOX 518
FONTANA, CA 92335
(909) 350-7610
OWNER &EVELOPER
ALPER DEVELOPMENT
6101 CHERRY AVENUE
FONTANA, CA 92336
(909) 899-0156
CONTACT: ROGER HATCH
COMCAST CABLEVISION
1205 DUPONT STREET
ONTARIO, CA 91761
(909) 988-8322 X3055
CONTACT: JACK HAYES
CONSTRUCTION NOTES & QUANTITIES:
VICINITY MAP
N.T.%
MARKS CABLEVISION
FIBER -OPTICS/ TRUNK LINK THROUGH PROJECT
4240 HALLMARK PARKWAY
SAN BERNARDINO, CA 92407
(909) 880-0220
CONTACT: JOE DEARMAN
CAB20VF
870 NORTH MOUNTAIN AVENUE
UPLAND, CA 91786
(909) 931-2472
CONTACT: DANIEL TUCKER
WMLTEL. MIG.
FIBER-OPTIC TELECOMMUNICATIONS
LAS VEGAS, NEVADA TO LOS ANGELES, CA
UPLAND, CA 91786
P.O. BOX 21348, MD 26-3
TULSA, OK 74121
918 588-3397
909 947-9441 (LOCAL CONTACT)
LOCAL CONTACT: JERRY KENNEDY
QUANTITY
ITEM
DESCRIPTION
UNIT
TRACT NO.
14573-1
O1
CONSTRUCT 8" EXTRA STRENGTH VCP SEWER LINE, BEDDING PER
2,440
LF
DETAIL ON SHEET 1.
OCONSTRUCT
48" DIA. ECCENTRIC MANHOLE PER CITY OF FONTANA
10
EA
STD. NO. 112.
CONSTRUCT 4" SEWER LATERAL AND HOUSE CLEANOUT PER CITY
OOF
FONTANA STD. NO. 125 AND INSTALL SEWER CLEAN-OUT BOX PER
1o400
LF
CITY OF FONTANA STD. NO. 125A (IN CONCRETE AREAS) OR 125B (IN
LANDSCAPE AREAS)
�4
INSTALL TEMPORARY PLUG
1
EA