HomeMy WebLinkAbout2451-11. A grading permit from the Suilding & Safety 'Division shall be required. All grading shall conform with the requirements of the City of Fontana Municipal Code and the Uniform Building Code, Latest Edition. 2. A pre—grading meeting at the site is required among the City Inspector, the Civil Engineer, the Soils Engineer and the Grading Contractor prior to grading. 3. Hours of operation are 7:00 am to 6:00 PM, Monday through Friday. 4. A separate Engineering Division permit shall be required for any improvements within the Public Right of Way. 5. It shall be the Contractor's responsibility to verify the location of all utilities or structures above or below ground, shown or not shown on these plans. He will be held responsible for all damage to any utilities that result for his operations. 6. Strict adherence to dust control requirements shall be enforced and adjacent streets are to be cleaned daily of all dirt and debris that is a result of this operation. 7. Separate permits from the City of Fontana Building & Safety Division shall be required for any walls. 8. The design Civil Engineer / Soils Engineer of record shall exercise sufficient control during grading and construction to ensure compliance with the plans, specifications and code requirements within his perview, The engineers shall submit acknowledgment concerning employment form to the City prior to issuance of a grading permit. 9. Revisions to these plans shall be submitted to the City Engineer for his review and approval. 10. The Civil Engineer shall submit written certification of completion of rough grading in accordance with the approved grading plan and certification of building pad elevation prior to issuance of the building permit. Pad elevation grading tolerance shall not exceed +�- 0.10. 11. An "as—built" grading pian shall be submitted at the completion of work. 12. All grading shall be performed under supervision of the soils engineer who shall certify that all fill has been properly placed and who shall submit a final compaction report for all fills over 1' in depth. 13. Fill areas shall be cleaned of all vegetation and debris, scarified to a minimum depth of 12 inches and inspected by the soils engineer prior to the placing of fill. 14. Unsuitable materials, such as top soli, weathered bedrock, etre., shall be removed as required by the soils engineer from all areas to receive compacted fill of drainage structure. 15. Maximum cut and, fill slopes shall be 2:1. 16. City approval of these plans does not relieve the contractor from responsibility for the correction of error and omission discovered during construction. Upon request, the required plan revisions shall be promptly submitted to the City Engineer for approval. 17. Construction material and equipment shall not occupy any portion of the public right of way, such as street, alley or public sidewalk at any time. Temporary use of public right of way, whenever requested, should be reviewed and approved by the City Engineer. is. Contractor shall contact So. Cal. Gas Co. regarding exW1n gas line south of Highland Avenue prior to beginning construction. Contractor shall also contact Crawford Canyon Mutual Water Co. regarding possible Water lines (unknown location) in Hemlock Avenue, Highland Avenue ands Beech Avenue. City of Fontana, utility notification list City of Fontana Pacific 'Bell Co. Attn: Carlos Navarro Attn: Virginia Becker 8353 Sierra Avenue 3939 E. Coronado Street Fontana, CA. 92335 Anaheim, CA. 92807 (909) 350-6632 (714) 666-5467 So. Calif. Gas Company Underground Service Alert Attn: Dennis Freeman (800) 422-4133 1981 W. Lugonia Avenue Redlands, CA. 92374 Comcast ( Cable TV ) (909) 335-7547 Attn: Jack Hayes Emergencies: (800) 427-2200 1205 Dupont Ave. Ontario, CA. 91761 So. Calif. Edison Company (909) 390-4738 300 N. Pepper Avenue Rialto, CA. 92376 General Telephone Company 1909 820-5598 — Underground Attn: Steve Hock 909 875-5100 — Transmission 1400 E. Phillips Blvd. 213 637-1233 — Pipelines Ontario, CA. 91766 909 357-6223 — Distribution (800) 422-4133 800 422-4133 Fontana Water Company Crawford Canyon Mutual Water Co. Attn: Michael J. McGraw Attn: Bill Vanderkieft, Jr. 8440 Nuevo Avenue (619) 868-6040 Fontana CA. 92235 F909) 822-220ax: (09) 82315045 19. We hereby certify that we have reviewed this pian, and that it substantially conforms to the soils report No. 58-5277-01, dated April 10, 1995 for Tract No. 15655. .0," Allen D. Evans, P.E., G.E. Kleinfelder, Inc. CITY OF FONTANA DETENTION BASIN IMPROVEMENTS ,' MAX SIZE NATIVE SOIL, COMPACTED 95% 6" MIN. 10" MAX. 1/2" CRUSHED — — STONE BEDDING PER STD. SPECS. FOR PUBLIC WORKS CONSTRUCTION TABLE 200-1.2(A) SHOWN BELOW TABLE: 200-1.2(A) SIEVE SIZE PERCENTAGE PASSING SIEVES 1 1 2" — 1" — 3/4" 100 2'—,' 90-100 3/ar 20-60 N0.4 0-15 x N0.8 0-5 ASTM C 131 TEST GRADING 9'-3" W z w FOR TRACT NO. 15655 HIGHLAND AVENUE er MIN. 10" MAX. e" MAX SIZE NA" SOIL, COMPACTED 90X 1" MAX. SIZE SELECTED NATIVE BEDDING COMPACT TO 909 IN I all 7ICAL113EC111 1 D DETAIL NOT TO SCALE MDR MAP SCALE: 1" HEADWALL SHALL BE (MONOLITHIC. LAP ALL BARS AT CORNERS 30 DIAMETERS IF NOT CONTINUOUS. PLANL owl ELEVATION 2— #4 OR #s SEE NOTE 2 #4 OR /S • 12' 1 � EW. SEE NOTE 2 T )UND #4 OR #S • 12" EW. SEE NOTE 2 HEADWALL DETAIL. NOT TO SCALE DIMENSIONS PIPE DIAM. L E F W 18" 4'-3" 2'—,' 3'-8" 2'-2" 30" 5'-5" 3'—Or 4'-6" 3'-0" 72" 9'-3" 4'—I' 8'-0'' 6'-8" N b v Ui �ECTiON A -PA NOTES: 1 • HEADWALL SHALL SE CONSTRUCTED OF CLASS A CONCRETE 2. REINFORCING STEEL SHALL BE #4 BARS FOR "1N' UP TO W. #5 BARS SHALL BE USED FOR "W" > 60" . 2" MIN. CLEARANCE , 30 DIAMETER MIN. LAP. 3. ALL EXPOSED CORNERS SHALL BE GIVEN A 1" CHAMFER. Q— CONSTRUCT TEMPORARY BRICK AND MORTAR BULKHEAD PER DETAIL HEREON t EA. Q— INSTALL 72' C.M.P, 10 GA. GALV. 129 L.F. Q5 -- CONSTRUCT CONCRETE APRON do HEADWALL PER DETAIL ON SHEET 1 3 EA. s�— CONSTRUCT 20'x20'x 12" CONC. OR A. B.M. PAD W/ 15"x6"00 Ga W.W.M. EMBED 12" MINIMUM SIZE RIP—RAP 2 EA. — REMOVE EXIST. WOODEN BULKHEAD AND CONSTRUCT CONCRETE BULKHEAD PER DETAIL HEREON. 1 EA. --- INSTALL 1 T CMP, 10 Ga., GALV. 56 L.F. 3 CONSTRUCT 6' WALL PER LANDSCAPE PLANS 970 L.F. �4 INSTALL 30" C.M.P. 10 Ga.. GALV. 110 L.F. 5 CONSTRUCT 36" CMP INLET PER DETAIL ON SHEET 1 1 EA. e CONSTRUCT 36" PCC GUTTER PER DETAIL HEREON 970 S.F. CONSTRUCT 3" AC PAVEMENT 550 S. F. MAS SCALE: 1"= 1 /2 mile L1\DWG\10201\0FFSITE\102010S7 3-25-97 2112743 pry EST A