HomeMy WebLinkAbout2443-5i
W N K '�" L N
v
rr-
-
CATCH BASIN (11 r
;Meg I I
POINT A ( POINT B POINT C t,� POINT p CURB
culls , B 1
T ' T {► T N GUTTED
T_
� !► R RIO T A ,<<E'y 4
POINT EISO �!► RSO
POINT F A LW8 POINT 6
-� DIRECTION OF FLOW R-_ DIRECTION OF FLOW
N K- We - L N u
1
POINT A POINT B POINT C FLOW LINE T B
FLOW LINE PROFILg
CASE
WN L WA L N
a W cum onNLN6
w, CATCH BASIN (S) I I
«y3 i I C
!:POINT A POINT B POINT L t POINT B CUMCUR��
40_
PONT E
POINT F C POMIT •
DIRECTION Of FLOW ONRECTION Of FLOW IL
+L - +
L -Ir
POINT 0
POINT A POINT • POINT C FLOW LINE
FLOW LINE PROFILE
M r 6• r
VAR.
VAR.
L
culls � �� •
FACE +H . 'y.► VALLEY
I
L .i.6.0 -
SECTION
! SECTION A - A, SECTION 8 -
� r
1- -
CURB POINT A
POINT E
a-- L WO-
CURBSw GRATIM p
CATCH BASIN (S)
POINT --
L ---------
r M, G, oR w1R r
VAR.
L
VALLEY
.4
SECTION C - C
- L N
CLNR>IB OPENING CATCH "ON (q
WITH GRATING ($)
C (SEE SHEET it
POINT C POINT D CRS
N GUTTER)
POINT f io. O L� C -POINT 6
PLAN
QAS
CUM OPENING CATCH BASIN WITH D CLAN OPENING CATCH BASIN WITH
pp
BOATING (S) AND DEBRIS -� - 't-1 MANHOLE IN STREET
ya SKIMMER -- ---
IwE
CUM POINT A POINT 0 'I ►DINT C NIIPOINT 0 CUM
GUTTE!j
29 N -
MAN
A
L(CASE wo
------
I 1
POINT A POMIT • C
FLOW LWI ( A E
FLOW LINE PROFILE
CASES C AND _D
>�'- f6IR IIMwNBL t
21-1 FOR FRAM[ OR
ANO GRATING IF
�•� �1RIT 6AMOE
cu"
FACELL .40.04L -I 4, 1
on -
I
PRAME MGRATiM
SECTION D - D
E `POINT 6
VWCTM of flow
L - N
-' T J
-fie► Pom T o T
IN I•
1/AR.
11.40 VALLEY
SECTION! E -E
K
+•- M'0
K
STANDARD PLAN
PIRor11LSA�eo N TME Awlrr►-Roc
JOINT (OOPEERATM CONMIITTEI
LOCAL DEPRESSIONS AT CATCH BASINS
313-0
lam
ECCENTRIC MANHOLE SHAFT
cum OPENING
CATCH BASIN (i)
------
r--
IN
I
I
rw c
WITH TWO 1/4' ROUND STEEL HOOPS&
t----------------1
6• AND 8' RINGS SHALL BE REINFORCED
-.---.•�
WITH FOUR HOOPS. TIED WITH NO. 14
S
3/4'
GAUGE wIRE 8. OC
21/e•
11/2•
POINT B POINT C
TR4
CUM
��PN1��
1 5/e'
�,<<E'� 0
r
GUTTER
_
--_moi
-PONT E
Ems.
LW C (SEE SHEET 1)
CASE
K
WO K -�
CURBSIDE GRATING
CATCH BASIN (S)
CUM OPENING CATCH BASIN (SI
WITH GRATING l$1IW
(; (SEE SHEET 11
--- - -
I
N
� -
CURB�.c
IL
f
GLITTER
POI------------�
r 1 1/4'
----�
►DINT E-� �', �- -�• - -
MOOT P POINT R
CASE f
K WID K
CUM OPEMN6 CATCH -- ----
BASMN WITH GRATING ($)-
AND DEBRIS SKIMMER I r i I
C
Ir
CURB � "mm � sr4 �
I POINT c ,Myr CURB a
=<<fYE OUT TER
v POINT B I = C1AN OPENING CATCH MSIN
/ WITH MANHOLE IN STREET - - -
T l=
POINT E C (KE SHEET 1)
POINT P POINT S
•- BR ECTI IN Of FLOW
J
:� A�
rr R K 2u
_u i
J
-T _ 1 t
T F10w LMR
1
(CASE E ) CA
S )
FLOW LINE PROFILE
CASES E. F AND Q
NOTES:
1. ALL EXPOSED EDGES SHALL BE ROUNDED TO A 1/2-94CN PA".
2. THE CURB FACE AT POINTS A AND D SHALL BE THE NORMAL CURB FACE OF THE ADJACENT CURB.
THE CURB FACE AT POINTS B AND C SHALL BE THE NORMAL CURB FACE OF THE ADJACENT CURB
PLUS H (SEE APPLICABLE CATCH BASIN STANDARD PLAN).
3. IN EXISTING STREETS WHERE NO PAVEMENT 11EMOOELMG IS :ATED. THE ELEVATION OF THE
OUTER EDGE OF THE LOCAL DEPRESSION SHALL MEET THE FINISHED STREET SURFACE.
4. IN NEW STREETS, OR IN EXISTING STREETS WHERE PAVEMENT REMODELING IS INDICATED:
THE ELEVATIONS OF POINTS F AND G SHALL BE SET H, H93HER THAN THE GUTTER FLOW LINE
ELEVATIONS AT POINTS A AND D. RESPECTIVELY
THE ELEVATIONS OF POINTS P AND R SHALL BE SET M: M113HER THAN THE GUTTER FLOW LINE
ELEVATIONS AT POINTS B AND C, RESPECTIVELY
THE ELEVATION OF POINT S SHALL BE SET M: 04OHM THAN THE ELEVATIM AT THE NEAREST
GUTTER FLOW LINE.
WHERE THERE IS NO GUTTER ADJACENT TO THE LOCAL DEPRESSION, THE ELEVATION OF POINT
E SHALL BE SET H3 HIGHER THAN THE ELEvAT10N AT THE NEAREST TOE OF CURB.
S. DIMENSIONS:
H - NOTED ON THE PROJECT PLANS.
H, - NOTED ON THE PROJECT PIANS.
Hz - NOTED ON THE PROJECT PIANS.
N3 - NOTED ON THE PROJECT PLANS.
0 - 2 FEET.
K - 5 FEET.
L - 6 FEET.
M - 4 FE ET.
N - 5 FEET.
Wo -CATCH BASIN W FOR ONE CATCH BASIN ON DISTANCE BETWEEN EXTREME END WALLS FOR
MULTIPLE CATCH BASINS.
THE THICKNESS OF THE LOCAL DEPRESSION SMALL BE 6 INCHES.
AMERICAN PIINLIC CORKS ASSOCIATION - lOVTHERN CALIFORNIA CHAPTER
Pt�or�L6IA1to.r TIE
MANHOLE SHAFT WITH
STANDARD PLAN
PIRor11LSA�eo N TME Awlrr►-Roc
JOINT (OOPEERATM CONMIITTEI
LOCAL DEPRESSIONS AT CATCH BASINS
313-0
lam
ECCENTRIC MANHOLE SHAFT
m WITH STAIMAIb SPEClICAT101M PORI PUBLIC WORKS Clumv INN
IN
SO TY►
7 1/r TYP
COVER FOR 24" CLEAR OPENING FRAME BOTTOM PLAN OF COVER
n/w
.- >rrMrMET111cAL AiouT E
a** t/mr_�
1.1 INS!'• TYi
t" I•��� t/R• RAQ ►ILLETSI SI4r
SECTION A -A
- ---- -----m
mr
SECTION THRU FRAME
QETAIL OF FRAME
NOTEs•
1. THE CAST IRON USED SHALL CONFORM WITH ASTM A48 CLASS 398.
2. THE FRAME AND COVER SHALL BE COATED WITH ASPHALTUM OR BITUMINOUS PAINT AFTER
TESTING AND INSPECTION.
3. COVERS SHALL BE CAST WITH THE LETTER "0" FOR STORM DRAINS AND "S" FOR SEWERS AND THE
AGENCY'S IDENTIFICATION IN ACCORDANCE WITH INSTRUCTIONS FURNISHED BY THE AGENCY. THE
LETTER "D" OR "S" SHALL BE APPROXIMATELY 2'/z INCHES HIGH WITH '/24NCH LINE WIDTH AND
PLACED IN THE CENTER OF THE COVER. ALL LETTERS SHALL BE FLUSH WITH THE FINISHED
SURFACE OF THE COVER.
4. FOUNDRY IDENTIFYING MARK, HEAT AND DATE SMALL BE CAST ON THE BOTTOM OF THE COVER
AND ON THE INSIDE OF THE FRAME.
S. IMPORTED COVERS AND FRAMES SHALL HAVE THE COUNTRY OF ORIGIN MARKING IN COMPLIANCE
WITH FEDERAL REGULATIONS. _
6. WEIGHT OF FRAME SHALL BE 260 POUNDS. WEIGHT OF COVER SHALL BE 175 POUNDS. ACTUAL
WEIGHTS SHALL BE WITHIN A RANGE OF 95% TO 1101✓&.
7. THE MANHOLE FRAME AND COVER SHALL BE INSPECTED BY THE ENGINEER PRIOR TO SHIPMENT
TO THE JOB SITE. ACCEPTANCE WILL BE INDICATED BY THE AGENCY'S MARK.
6. THE PROOF -LOAD FOR TEST METHOD B OF THE STANDARD SPECIFICATIONS IS 40,700 POUNDS.
9. COVERS FOR MANHOLES LOCATED IN EASEMENTS, ALLEYS. PARKWAYS AND ALL OTHER PLACES
EXCEPT PAVED STREETS SHALL BE PROVIDED WITH SOCKET SET SCREW LOCKING DEVICES. DRILL
AND TAP TWO HOLES TO A DEPTH OF ONE INCH AT 90 DEGREES TO PICK HOLE AND INSTALL 3Y.•INCH
X 3/4 -INCH STAINLESS STEEL SOCKET SET SCREWS WITH %-INCH RECESSED HEX HEAD. ALL
THREADS SHALL BE N.C.
AMERICAN PUBLIC WORKS ASSOCIATION - 90UTWRN CALIFORNIA CHAPTER
Pt�or�L6IA1to.r TIE
MANHOLE SHAFT WITH
sTANOnno PLAN
PIRor11LSA�eo N TME Awlrr►-Roc
JOINT (OOPEERATM CONMIITTEI
24 -INCH MANHOLE FRAME AND COVER
030-1
lam
ECCENTRIC MANHOLE SHAFT
IIa WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS
MANHOLE FRAME
AND COVER PER
STD. PLAN 630
R = 2'
24-
z
'z '
s
N •
I/S• 36' DIA
MINIMUM
Q
i
�-- FINISHED GRADE OR
SPECIFIED ELEVATION
MANHOLE FRAME
COLLAR. CLASS C MORTAR AND COVER PER
'STD. PLAN 630
STD. CONCRETE RINGS. 30. � '
6' OR 16' IN THICKNESS.
SEE NOTE 6
WHEN POSSIBLE uSE ' R s 2'
4-2 I/2' RINGS �I
OR EOUIVALENT I
18' MAXIMUM' 4' •4 WIRE
\-SEE RING SECTION DIA. HOOPS
_�-FOR JOINT DETAILS
�
72 EOCOILS.
U R,ED z 6.
`-
92 TIE BARS a
4 REOUIRED a '
� I I
ECCENTRIC PRECAST
CONCRETE CONE-
VARIABLE
ONE VARIABLE LENGTH PRECAST CONCRETE
SECTIONS. 6' MIN. THICKNESS FOR
PLAIN CONCRETE. 4' MIN. THICKNESS
FOR REINFORCED CONCRETE-
360
ONCRETE 36• SPECIAL MH RCP WITH I
A CIRCUTAR CAGE AND 1+
IOOOD MINIMUM
ANY STANDARD 36•
PIPE END DIA.
CLASS C MORTART VERTICAL SECTION
OF PLAIN CONCRETE
ECCENTRIC MANHOLE SHAF'"T
VERTICAL SECTION
Pt�or�L6IA1to.r TIE
MANHOLE SHAFT WITH
P
nummRD"I"
OF REINFORCED CONCRETE
ECCENTRIC REDUCER
324-0
M WITH STANDARD SPECIFICATION: FOR Pumm WORKS CONStMIC 1
ECCENTRIC MANHOLE SHAFT
2 1/2' RINGS SHALL BE REINFORCED
WITH TWO 1/4' ROUND STEEL HOOPS&
6• AND 8' RINGS SHALL BE REINFORCED
WITH FOUR HOOPS. TIED WITH NO. 14
S
3/4'
GAUGE wIRE 8. OC
21/e•
11/2•
.
1/4'
1 5/e'
/a•
o
_
N'f
N
� -
�+
INSIDE DIAMETER 240
r 1 1/4'
1/2•
1•
1 3/4•
I/4'
•
CROSS
SECTION
OF
REINFORCED CONCRETE
RING
NOTE�
I. UNLESS OTHERWISE INDICATED THIS STRUCTURE SHALL CONFORM TO
ASTM C 478 AND ALL CONCRETE SHALL Bf PER SSPWC.
2. MANHOLE FRAME AND COVER SHALL CONFORM TO STANDARD PLAN 630.
3. ALL JOINTS SHALL BE SEALED BY FILLING THE ANNULAR SPACES
WITH CLASS C MORTAR. THE INSIDE OF THE SHAFT AT EACH JOINT
SHALL BE WIPED CLEAN OF EXCESS MORTAR.
4. PROTECTIVE PLASTIC LINER (T LOCK) OR ENGINEER -APPROVED COAT-
INGS WHERE REQUIRED BY THE PROJECT DRAWINGS SHALL BE IN
ACCORDANCE WITH SSPWC AND THE MANUFACTURER'S DIRECTIONS.
S. STEPS SHALL CONFORM TO STANDARD PLAN 635 OR 636. THE TOP
STEP SHALL BE PLACED DIRECTLY BENEATH THE MANHOLE FRAME.
UNLESS OTHERWISE SHOWN, STEPS SHALL BE UNIFORMLY SPACED 140
TO 15" OC.
6. THE ECCENTRIC MANHOLE, SHAFT REDUCER AND RINGS MAY BE PLAIN
CONCRETE. FOR PLAIN CONCRETE SECTIONS THE MINIMUM THICKNESS
SHALL BE 60.
7. THE PRECAST CONCRETE MANHOLE STRUCTURES WILL BE INSPECTED
BY THE ENGINEER WHO WILL INDICATE ACCEPTANCE FOR SHIPMENT TO
THE JOB BY MARKING -THE STRUCTURES WITH THE AGENCY'S STAMP.
S. THE VERTICAL SIDES OF THE MANHOLE SHAFT AND THE ECCENTRIC
REDUCER SHALL BE LOCATED ABOVE AND IN LINE WITH THE SIDE OF
THE STORM DRAIN CONDUIT.
THE FOLLOWING STANDARD PLANS ARE INCORPORATED HEREIN:
630 24 -INCH MANHOLE FRAME AND COVER
635 STEEL STEP
636 POLYPROPYLENE PLASTIC STEP
AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER
Pt�or�L6IA1to.r TIE
MANHOLE SHAFT WITH
P
nummRD"I"
'°B'T CDD, C°""'"
ECCENTRIC REDUCER
324-0
M WITH STANDARD SPECIFICATION: FOR Pumm WORKS CONStMIC 1