HomeMy WebLinkAbout6526-1 (3)CITY OF FONTANA UTILITY NOTIFICATION LIST:
CITY OF FONTANA, CALIFORNIA
STREET IMPROVEMENT PLANS
BASIS OF BEARINGS:BENCH MARK:
909.581.0676
3257 E Guasti Rd, Suite 300
Ontario, California 91761
fuscoe.com
CITY OF FONTANA
STREET IMPROVEMENT PLANS
VENTANA JOHN PREVITI AVENUE
LIST OF ABBREVIATIONS:
MCN20-099R1
SITE
9/24/2025
CONSTRUCT CROSS GUTTER AND SPANDREL PER CITY STD. PLAN NO. 1013.
CONSTRUCT CURB RETURN ACCESS RAMP PER CITY STD. PLAN NO. 1003.
1
2 EA
1 EA
6,170 SF
REV 2 ONLY:1
2-4-26
1 SEE SHEET 6 & 7
1.ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT
PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL REFERENCE
SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED.
2.WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY
REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID
CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
3.ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4.CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT,
ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST
TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909)
350-7610.
5.THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN
THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON-METRIC EDITION UNLESS OTHERWISE DIRECTED BY
THE CITY TRAFFIC ENGINEER.
6.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC
CONTROL DEVICES AT ALL TIMES.
7.THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR
GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
8.THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING,
SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL
SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL
EXISTS FOR GROUND MOVEMENT.
9.NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT-OF-WAY WITHOUT OBTAINING A SEPARATE PERMIT
FOR THAT PURPOSE.
10.THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE
THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY
EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL
CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION.
11.THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO,
GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED
WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING
DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES.
12.THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY
AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND
WATER REQUIREMENTS.
13.CURVE DATA REFERS TO THE FACE OF CURB.
14.STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT WHERE OTHERWISE NOTED.
15.ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO
CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF
BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION.
16.THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT
PRIOR NOTIFICATION TO THE CITY ENGINEER.
17.REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND
BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS
THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE
ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER
REPLACEMENT OF THE MONUMENT.
18.THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT
LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES.
19.THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE
WATERING, AT ALL TIMES.
20.ALL GRADING OPERATIONS SHALL BE DISCONTINUED WHEN SUSTAINED WIND VELOCITIES EXCEED 25 MILES PER HOUR.
21.THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC
OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL.
22.NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
23.A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY
SHALL REQUIRE RE-WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED.
24.CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS.
UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODABLE SWALES ENTERING OR
LEAVING IMPROVEMENTS.
25.THE FINAL LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS SHALL BE APPROVED AT THE TIME OF
CONSTRUCTION AND SHALL CONFORM TO THE CITY OF FONTANA STANDARD DETAILS.
26.ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE.
27.THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER LATERAL.
28.NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND
APPROVED.
29.ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS.
30.APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT.
31.PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION AND APPROVAL OF THE CITY
ENGINEER AS DETERMINED BY SOILS TESTS TAKEN AFTER COMPLETION OF ROUGH GRADING.
32.ACTUAL THICKNESS OF A.C. PAVEMENT AND/OR BASE COURSE MATERIAL FOR STRUCTURAL STREET SECTIONS SHALL BE
RECOMMENDED BY A GEOTECHNICAL REPORT AND SUBMITTED TO THE CITY OF FONTANA FOR APPROVAL UPON COMPLETION
OF ROUGH GRADING.
33.ALL MANHOLES, CLEANOUTS, FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE
PAVING CONTRACTOR UPON COMPLETION OF PAVING.
34.UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND
OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
35.CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALKS AFFECTED BY THE
CONSTRUCTION TO THE SATISFACTION OF THE CITY ENGINEER.
36.AS-BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE
DRAWINGS TO THE CITY ENGINEER.
STREET GENERAL NOTES:
PRIVATE ENGINEER'S NOTICE TO CONTRACTORS:
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED
BY A SEARCH OF AVAILABLE RECORDS; TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE
SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE
UTILITY LINES SHOWN ON THESE DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR
THE UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS.
THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITIONS
DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT; INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS
SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL
DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED,
IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE
NEGLIGENCE OF THE OWNER OR THE ENGINEER.
CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT ALL DISCREPANCIES TO THE ENGINEER
PRIOR TO THE COMMENCEMENT OF ANY WORK. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE ENGINEER OF
ANY DISCREPANCY.
BEGINNING OF WORK MEANS ACCEPTANCE OF CONDITIONS.
CONTRACTOR SHALL COMPLY WITH ALL N.P.D.E.S. REQUIREMENTS.
CONTRACTOR SHALL ADJUST TO FINISH GRADE ALL MANHOLE RIMS, WATER VALVE BOXES, UTILITY BOXES AND LIDS, ETC.
CONTRACTOR SHALL PROVIDE ALL THE NECESSARY PIPE FITTINGS TO COMPLETE THE WORK.
THE ENGINEER PREPARING THESE PLANS SHALL NOT BE HELD RESPONSIBLE OR LIABLE FOR UNAUTHORIZED CHANGES TO OR
USES OF THESE PLANS. ALL CHANGES TO THESE PLANS MUST BE REQUESTED IN WRITING AND MUST BE APPROVED BY THE
ENGINEER OF RECORD.
THE BEARINGS SHOWN HEREON ARE BASED THE ON NORTH AMERICAN
DATUM OF 1983 (NAD-83), SHOWN IN TERMS OF THE CALIFORNIA
COORDINATE SYSTEM OF 1983 (CCS-83), ZONE V (2011.00 EPOCH DATE)
AS DERIVED BY POSITIONS PUBLISHED BY CSRC. ALL COORDINATE
VALUES WERE SCALED TO GROUND BY APPLYING AN AVERAGE
COMBINATION FACTOR AS DETERMINED BY FEI POINTS 11012, 11014,
11022, 11025, 11029, AND 11034 AND HOLDING THE COMPUTED GRID
COORDINATE ON POINT 11015. INVERSES BETWEEN PROJECT
COORDINATES WILL PRODUCE GROUND DISTANCES. TO OBTAIN GRID
DISTANCES MULTIPLY GROUND DISTANCES BY 0.999888867
THE CONTOURS AND ELEVATIONS SHOWN HEREON
ARE BASED ON THE FOLLOWING BENCH MARK:
BM NO.: EV9274 ELEV.: 1508.56' (NGS BENCH MARK)
DATUM: NAVD 88 1993 ADJ
NATURAL GAS:
THE GAS COMPANY, SEMPRA UTILITIES
16231 VALLEY BLVD.
FONTANA, CA 92235
ELECTRIC:
SOUTHERN CALIFORNIA EDISON COMPANY
7951 REDWOOD AVENUE
FONTANA, CA 92336
PHONE: 909.357.6221
WATER:
WEST VALLEY DISTRICT
855 W. BASELINE ROAD
RIALTO, CA 92377
PHONE: 800.427.2200, 909.428.8411
PHONE: 909.875.1361
WATER:
FONTANA WATER COMPANY
15966 ARROW ROUTE
FONTANA, CA 92335
PHONE: 909.822.2201
WATER:
CRAWFORD CANYON MUNICIPAL WATER
DISTRICT 21559 LITTON AVE
GRAND TERRACE, CA 92313
PHONE: 909.824.5352
SEWER:
CITY OF FONTANA
8353 SIERRA AVENUE
FONTANA, CA 92235
PHONE: 909.350.6652
SEWER TREATMENT FACILITIES
INLAND EMPIRE UTILITY AGENCY
12645 6TH STREET
RANCHO CUCAMONGA, CA 91739
PHONE: 909.947.4131
SOLID WASTE:
BURRTEC WASTE
9454 CHERRY AVENUE
FONTANA, CA 92335
PHONE: 909.822.9739
TELEPHONE:
AT&T
11464 TELEGRAPH ROAD
SANTA FE SPRINGS, CA 90670
PHONE: 714.666.5415
CABLE SERVICES:
TIME WARNER CABLE 1205
DUPONT AVENUE
ONTARIO, CA 91761
PHONE: 909.390.4738
GEOTECHNICAL:
GEO TEK, INC.
1548 NORTH MAPLE STREET
CORONA, CA.92880
PHONE: (951) 710-1160
PROJECT NO.2541-CR
SOIL REPORT DATED: OCTOBER 16, 2020
CONTACT: ANNA M. SCOTT - PROJECT GEOLOGIST
ENGINEER:
FUSCOE ENGINEERING INC.
3257 E GUASTI RD, SUITE 300
ONTARIO, CALIFORNIA 91761
(909) 581-0676
CONTACT: LUIS FIGUEROA
OWNER DEVELOPER:
THE PREVITI GROUP
2151 E. CONVENTION CENTER WAY, SUITE 114
ONTARIO, CALIFORNIA 91764
PHONE: 909.354.8092
CONTACT: STEPHEN KING
CONSTRUCT 4" THICK P.C.C. SIDEWALK PER CITY STD. PLAN NO. 1006 (W = PER PLAN) &
DETAIL B/3 ON SHEET 3 WHERE APPLICABLE.
SHEET INDEX:
SHT. NO.DESCRIPTION
1.TITLE SHEET
2.TYPICAL SECTIONS
3.DETAIL SHEET
4.JOHN PREVITI AVENUE PLAN & PROFILE
5.JOHN PREVITI AVENUE PLAN & PROFILE
6.JOHN PREVITI AVENUE PLAN & PROFILE
7.JOHN PREVITI AVENUE PLAN & PROFILE
PRIVATE ENGINEER'S NOTE:
THE PRIVATE ENGINEER SIGNING THESE PLANS IS RESPONSIBLE FOR ASSUMING THE ACCURACY
AND ACCEPTABILITY OF THE WORK HEREON. IN THE EVENT OF DISCREPANCIES ARISING DURING
CONSTRUCTION, THE PRIVATE ENGINEER SHALL BE RESPONSIBLE FOR DETERMINING AN
ACCEPTANCE SOLUTION AND REVISING THE PLANS FOR APPROVAL BY THE CITY.
CENTERLINE
PROPERTY LINE
RIGHT OF WAY
EXISTING LOT LINE
EXISTING EASEMENT
EXISTING SPOT ELEVATION
EXISTING CONTOUR
PROPOSED CONTOUR
PROPOSED EASEMENT
PROPOSED LOT LINE
EDGE OF EX. A.C. PAVEMENT
EXISTING SEWER
EXISTING WATER
EXISTING STORM DRAIN
FUTURE STORM DRAIN
PROPOSED STORM DRAIN
CATCH BASIN & LOCAL DEPRESSION
FLOW ARROW & GRADE
GRADED SWALE
TOP OF SLOPE
TOE OF SLOPE
DAYLIGHT LINE
EXISTING SURFACE/CURB
FUTURE CURB
FLOW ARROW
STREET CONSTRUCTION NOTES:
VICINITY MAP
SHEET INDEX MAP
SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE
WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED
FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO
THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND
STANDARDS IN EFFECT.
CLOUDED AREAS ARE NOT A PART OF PLAN
APPROVAL DATED _____________, 2025.
TITLE SHEET
REVISION DESCRIPTION DATE DATEENGR.CITYREV.
STEVEN L.ELLIS
P PROTECT IN PLACE
CONSTRUCT 6 1/2" A.C. PAVEMENT (MIN.) OVER 12" NATIVE MATERIAL COMPACTED TO 95% (SEE GENERAL NOTES 30 & 31).
CN DESCRIPTION QUANTITIES UNIT
SF
SF
SF
LF
LF
LF
LF
LF
EA
EA
EA
EA
EA
EA
CF
1
QUANTITIES SHOWN HEREON ARE PROVIDED FOR PERMIT AND BONDING PURPOSES ONLY. CONTRACTOR SHALL BE
RESPONSIBLE FOR DETERMINING THEIR OWN QUANTITIES PRIOR TO BIDDING AND CONSTRUCTION. THE ENGINEER IS NOT
RESPONSIBLE FOR DISCREPANCIES IN FINAL CONSTRUCTION QUANTITIES.
CONSTRUCT 8" CF P.C.C. CURB & GUTTER PER CITY STD. PLAN NO. 1000.2
3
4
5
6
7
8
9
10
11
PROVIDE 2" × 5' GRIND AND OVERLAY, SEE DETAIL A/3 ON SHEET 3.
CONSTRUCT LOCAL DEPRESSION PER CITY OF FONTANA STD. PLAN NO. 3003, CASE PER PLAN AND DETAILS ON SHEET 3.
CONSTRUCT CATCH BASINS PER STORM DRAIN PLANS DWG. 6527.
INSTALL STREET LIGHT PER STREET LIGHT PLAN PER DWG. 6526LT AND DETAIL ON B ON SHEET 3 WHEN APPLICABLE.
ADJUST MANHOLE TO GRADE.
ADJUST WATER VALVE RIM TO GRADE.
REMOVE EXISTING A.C. DIKE.
REMOVE EXISTING STANDARD BARRICADE.
INSTALL IRRIGATION PIPE SLEEVES 1-6" AND 1-4".
NOT USED.
CONSTRUCT EARTHEN SWALE ALONG EDGE OF SLOPE PER DETAIL C/3 ON SHEET 3.
CONSTRUCT 6"×10" RIP RAP NO. 3 BACKING THICKNESS = 24" MIN.
CONSTRUCT 8" CF P.C.C. CURB PER CITY STD. PLAN NO. 1000.
CONSTRUCT 8" A.C. DIKE PER CITY STD. PLAN NO. 1007.
12
13
14
15
16
17
CONSTRUCT 4" THICK P.C.C. SIDEWALK PER CITY STD. PLAN NO. 1006 (W = PER PLANS) & DETAIL B/3 ON SHEET 3 WHERE APPLICABLE.
186.135
11.560
665
6.113
310
565
3,490
480
6
6
25
19
17
1
120
LF100
18
19
3
∡PT ANGLE POINT
A.C., AC ASPHALT CONCRETE
AC.ACRE
A.B.AGGREGATE BASE
BC BEGIN OF CURVE
BCR BEGIN OF CURB RETURN
BVC BEGIN VERTICAL CURVE
CF CURB FACE
CB CATCH BASIN
C/G CURB & GUTTER
C/L, CL, ℄CENTER LINE
CONC.CONCRETE
CY CUBIC YARD
D-LOAD RCP DESIGN LOAD
DW, W DOMESTIC WATER, WATER
DWY DRIVEWAY
E.A., EA EACH
EC END OF CURVE
ECC EDGE OF CONCRETE CHANNEL
ECR END OF CURB RETURN
EG EXISTING GROUND
EL., ELEV ELEVATION
EP EDGE OF PAVEMENT
EVC END VERTICAL CURVE
EX., EXIST., (E)EXISTING
FH FIRE HYDRANT
FG FINISH GRADE
FL FLOWLINE
FS FINISHED SURFACE
GB GRADE BREAK
HP HIGH POINT
INV INVERT
JT., JNT.JOINT
L LENGTH
L.F., LF LINEAL FEET
L.O.C.LENGTH OF CURB
LSCP., LS LANDSCAPE
MAX MAXIMUM
MIN MINIMUM
MH MANHOLE
(N)NEW
NG NATURAL GROUND
N.T.S., NTS NOT TO SCALE
PCC POINT OF COMPOUND CURVE
P.C.C.PORTLAND CEMENT CONCRETE
PI POINT OF INTERSECTION
PRC POINT OF REVERSE CURVE
P.L., PL PROPERTY LINE
PROP.PROPOSED
R/W RIGHT OF WAY
RW RETAINING WALL
SCE SOUTHERN CALIFORNIA EDISON
SD STORM DRAIN
S SLOPE
S, SW, SS SEWER, SANITARY SEWER
SIM.SIMILAR
SF, S.F.SQUARE FEET
SDMH STORM DRAIN MANHOLE
SMH SEWER MANHOLE
STA STATION
TD TOP OF DIKE
TC TOP OF CURB
TYP., TYP TYPICAL
VAR.VARIES
W, DW WATER, DOMESTIC WATER
LEGEND:
SEWER OR STORM DRAIN MANHOLE
ELPC24-00110
DRAWN BY:
DESIGN BY:
JV
CA
CHECKED BY:
SE/LAF
APPROVED BY:
GIA LAM KIM / CITY ENGINEER R.C.E. 62296 DATE
SCALE:
AS SHOWN
DATE:
SEPTENBER 2025
DRAWING NO.
6526
1
7
ELPC26-00019 R1
1
9/10/26