HomeMy WebLinkAbout6356-1E
T
E
10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00
CY
P
R
E
S
S
A
V
E
N
U
E
VALLEY BOULEVARD
L = 50'
L = 50'
1
12
'
12
'
VA
R
11
'
12
'
12
'
VA
R
15'12'12'12'12'
13
'
12
'
13
'
12
'
VA
R
VA
R
VAR 11'11'13'5'12'
8 8
33
(1
3
'
)
(1
2
'
)
111111
10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00
EX
S
T
.
R
/
W
EXIST. BUS STOP EXIST. DWY
NE
W
RA
I
S
E
D
ME
D
I
A
N
EXIST. R26(S)(CA)
W9-1
13 13
13
7
7
11
11
11
16
TYPE VI (L)TYPE VI (L)
6NEW R4-7
+OM2-H1
W4-2 5
4
CONSTRUCTION C/L
SURVEY C/L
4
5
240'
5
7
7
R4-1
70
'
R28(S)(CA)10
13
FH
FH
FH
66
'
67
'
54
'
55
'
FH
15
'
R28(S)(CA)10
EXIST. R2-1(45)
12 12
12
12 12
JOIN EX. STRIPING
END TAPER
STA 14+44.67
L=280' SHIFTING TAPER (65:1 RATIO)@4.3' SHIFT
17+00 18+00 19+00 20+00 21+00 22+00 23+00 23+20
VALLEY BOULEVARD 1
17+00 18+00 19+00 20+00 21+00 22+00 23+00 23+20
L=50'
L=50'1
EX
I
S
T
.
R
/
W
PR
O
P
.
R
/
W
EX
S
T
.
R
/
W
EX
S
T
.
R
/
W
EXIST. DWY EXIST. DWY
EXST. R/W
NE
W
S
I
D
E
W
A
L
K
12
'
12
'
VA
R
VA
R
12
'
VA
R
(1
3
'
)
3
11 TYPICAL
14
'
13
'
VA
R
12
'
VA
R
VA
R
(1
3
'
)
13
EXIST. R26(S)(CA)
EXIST. R9-3
EXIST. R3-1
R26(S)(CA)
3
1111
3
TYPE VI (L)
R4-7
+OM2-H1
TYPE IV (L)
6
JU
N
I
P
E
R
A
V
E
CONSTRUCTION C/L
PROTECT EXIST.
R3-1
SURVEY C/L
9
9
5
4
4
6
NE
W
R
A
I
S
E
D
ME
D
I
A
N
FH
FH
13
66
'
67
'
54
'
55
'
15
'
FH
13
3TYPE VI (L)
7
7
7
7 2
L=251'
R3-1
+"TRUCKS"
L=50'11
11
114 14
'
12
'
12
'
12
'
12
'
13
'
17
'
4'
FH
NE
W
C
U
R
B
&
G
U
T
T
E
R
NE
W
S
I
D
E
W
A
L
K
NE
W
C
U
R
B
&
G
U
T
T
E
R
R28(S)(CA)10 R28(S)(CA)10
20+00
19
+
0
0
8.0'
11'11'VAR
TYPE VII (R)
15
14
11 11
1111
11
L=360' SHIFTING TAPER (45:1 RATIO)@8' SHIFT
BEGIN TAPER
STA. 22+18.47END TAPER
STA. 18+58.47
BEGIN TAPER
STA. 17+24.67
2
14
L=
1
0
0
'
11
21
+
0
0
22
+
0
0
23
+
0
0
EXST. R/W
BEGIN TAPER
(AT DRIVEWAY BCR)
STA. 23+22.00
END TAPER
STA. 21+72.00
15
L=
1
5
0
'
S
H
I
F
T
I
N
G
T
A
P
E
R
(
2
5
:
1
R
A
T
I
O
)
@
6
'
S
H
I
F
T
BEGIN TAPER
STA. 22+82.00
4 L=110' SHIFTING TAPER
(110:1 RATIO) @1' SHIFT
END TAPER
STA. 21+72.00
17 L=110' SHIFTING TAPER
(55:1 RATIO) @2' SHIFT
2
17
13
R28L(S)(CA)PR
O
P
.
R
/
W
EX
I
S
T
.
R
/
W
EX
I
S
T
.
R
/
W
JUNIPER AVENUE
65
.
0
'
32
.
0
'
33
.
0
'
12
'
VA
R
VA
R
NEW DWYNEW DWY
EXIST. DWY EXSIT. DWY
EXIST. R26(S)(CA)EXIST. R26(S)(CA)
EXIST. R26(S)(CA)
R26(S)(CA)
R5-2+R20D-1(CA)(5)
R5-2+R20D-1(CA)(5)
5
6
5
6
R28R(S)(CA)10
R26(S)(CA)5
R28LR(S)(CA)6
12 12
12
12
12+00 13+00 14+00 15+00 16+00 17+00
18+00
13
FH
13
FH
FH
GRAPHIC SCALE
SCALE: 1" =
0 40'80'
40'
20'40'
MA
T
C
H
L
I
N
E
S
T
A
1
7
+
0
0
SE
E
B
E
L
O
W
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
BEFORE
YOU DIG
TOLL FREE
DIAL
DAYS BEFORE
1-800-422-4133
TWO WORKING
YOU DIG
REV.REVISION DESCRIPTION ENGR.DATE CITY DATE
CHECKED BY:
DESIGNED BY:
AND CARRIED FORTH IN A DILIGENT MANNER, THE
STANDARDS IN EFFECT.
PLANS TO BRING THEM INTO CONFORMANCE WITH
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
IMPROVEMENTS NOT COMMENCE WITHIN TWO
SHOULD CONSTRUCTION OF THE REQUIRED
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
Prepared Under The Supervision Of :
Date:
DRAWN BY:
1
CITY OF FONTANA, CALIFORNIA
APPROVED BY:DRAWING NO.:
6356
DATE:
SCALE:
SIGNING AND STRIPING PLAN
PM 20669
VALLEY BOULEVARD AND JUNIPER AVENUE
GIA LAM KIM
DATE:
AS SHOWN
NT
NT
DC
5/20/2026
DAVID J. CURTIS R.C.E. 75791
BASIS OF BEARINGS BENCH MARK:
CITY OF FONTANA BENCHMARK THE BASIS OF BEARINGS FOR THIS SURVEY IS THE
CALIFORNIA STATE PLANE COORDINATE SYSTEM,
ZONE 5, CONSTRAINED LOCALLY BETWEEN
CONTINUOUS GPS STATIONS EWPP & RTHS. SAID
BEARING IS S84°19'30"E (NAD83(2011) 2017.50
EPOCH.)
GPS CONTINUOUS OPERATING REFERENCE STATION
EWPP. THE ANTENNA IS AN ASHTECH 701945B_M
W/SCIT DOME. TRUE VERTICAL ANTENNA HEIGHT IS
FROM THE GEODETIC REFERENCE POINT TO THE
BOTTOM OF THE ANTENNA PRE-AMP(BPA) AND IS
0.027 FEET.
ELEVATION = 1194.52
R.C.E. 62296 CITY ENGINEER
1650 SPRUCE STREET, SUITE 400
RIVERSIDE, CA 92507
951.787.8421 www.psomas.com
1
No. C75791REGISTERED P ROFESSIONAL E
N
G
I
N
E
ER
S
T
A
TE OF CA L I F O R NIA
CI V I L
DAV I D J . CU
R
T
I
S
5/20/26
TPC24-00163
MA
T
C
H
L
I
N
E
S
T
A
1
7
+
0
0
SE
E
A
B
O
V
E
R2-1 SPEED LIMIT
R4-1 DO NOT PASS
R28LR(S)(CA) NO STOPPING ANY TIME
R3-1 NO RIGHT TURN
W4-2 RIGHT LANE ENDS
W9-1 RIGHT LANE ENDS
TRUCKS
R4-7 MEDIAN
OM2-1H TYPE K-1
MATCHLINE STA 18+90
SEE BELOW
MA
T
C
H
L
I
N
E
S
T
A
1
8
+
9
0
SE
E
A
B
O
V
E
R5-2 NO TRUCKS
R20D-1(CA)(5)
5 TONS
CONSTRUCTION NOTES
ITEM DESCRIPTION
1 APPLY THERMOPLASTIC 6" WHITE LANE LINE (TYP 50')
2
3 APPLY ARROW LEGEND AS SHOWN ON PLAN
4
5 REMOVE EXISTING SIGN AND POST
6
9
FURNISH AND INSTALL SIGN ON STREET LIGHT POLE
11
REFRESH EXISTING STRIPING/ MARKINGS AS NECESSARY12
10
REMOVE STRIPING/LEGENDS COMPLETE
8 APPLY PAVEMENT LEGEND AS SHOWN ON PLAN
FURNISH AND INSTALL NEW SIGN AND POST AS SHOWN
13
7
SIGNING AND STRIPING GENERAL NOTES:
CITY OF FONTANA
SIGNING AND STRIPING PLAN
VALLEY BOULEVARD AND JUNIPER AVENUE
PARCEL MAP NO. 20669 APPLY THERMOPLASTIC 6" WHITE DASHED LANE LINES
PER CALTRANS DETAIL 12A
APPLY THERMOPLASTIC CHANNELIZING STRIPE PER
CALTRANS DETAIL 38
INSTALL BLUE RPM MARKER FOR HYDRANT LOCATION
AT 6" OFF CURB OR LEFT-EDGE STRIPE
APPLY THERMOPLASTIC 12" WHITE CROSSWALK
APPLY THERMOPLASTIC 6" YELLOW STRIPING PER
CALTRANS DET. 25A
OVER
SIGN SIZE(INCHES)
SIGN TYPE & SIZE
SIGN DESIGNATION
30x36
24x30
12x18
24x24
36x36
36x36
24x30
24x24
12X6
24x6
24x6
14 APPLY 8" DIAGONAL STRIPING SPACED 30' C-C.
15 APPLY 6" WHITE STRIPING PER CALTRANS DET. 27B.
R26(S)(CA) NO STOPPING ANY TIME 12X18
16 APPLY THERMOPLASTIC CHANNELIZING STRIPE PER
CALTRANS DETAIL 38A
R28R(S)(CA) NO STOPPING ANY TIME 12x18
R28L(S)(CA) NO STOPPING ANY TIME 12x18
1.ALL WORK, MATERIALS, EQUIPMENT AND TEMPORARY TRAFFIC CONTROL SHALL CONFORM TO
THESE PLANS, THE CITY OF FONTANA DESIGN STANDARDS, THE CITY'S SPECIAL PROVISIONS,
SECTION E, CALTRANS STAND PLANS AND SPECIFICATIONS, AND THE CALIFORNIA MANUAL ON
UNIFORM TRAFFIC CONTROL DEVICES, LATEST EDITIONS.
2.ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA
DEPARTMENT OF ENGINEERING PRIOR TO COMMENCEMENT OF WORK.
3.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAINTAIN TEMPORARY TRAFFIC
CONTROL AT ALL TIMES.
4.ALL SIGNS SHALL BE INSTALLED PER CITY DESIGN STANDARD 4003, UNLESS OTHERWISE
SPECIFIED ON THE PLANS. SIGNS AND SIGNPOSTS THAT ARE REMOVED SHALL BE SALVAGED
TO THE CITY YARD AT 16489 ORANGE WAY.
5.ALL STRIPING SHALL BE ALKYD THERMOPLASTIC UNLESS OTHERWISE NOTED. STRIPING AND
PAVEMENT LEGENDS SHALL BE APPLIED IN ACCORDANCE WITH MANUFACTURERS
SPECIFICATIONS.
6.ON ROADWAYS WITH RAISED MEDIANS, SUBSTITUTE TYPE "C" RAISED PAVEMENT MARKERS FOR
TYPE "G" MARKERS ON DETAIL 38 AND 37B STRIPING.
7.STRIPING AND PAVEMENT MARKINGS TO BE REMOVED SHALL BE REMOVED BY SANDBLASTING OR
OTHER APPROVED METHOD, NONE OF WHICH SHALL DAMAGE THE PAVEMENT. THE 'BLACK OUT'
METHOD OF REMOVAL IS NOT PERMITTED. ANY PAVEMENT DAMAGED BY REMOVALS SHALL BE
REPAIRED PER APPROVAL BY THE CITY ENGINEER AT NO COST TO THE CITY.
8.PARKING RESTRICTIONS (RED CURB, SIGNAGE) SHALL BE INSTALLED ONE WEEK PRIOR TO
INSTALLATION OF STRIPING.
9.ALL STRIPING AND SIGNS (OTHER THAN PARKING RESTRICTION SIGNS) SHALL BE
APPLIED/INSTALLED AT THE SAME TIME.
10.IF SIGNS ARE TO BE PLACED ON A DEVICE (SUCH AS A STREET LIGHT POLE) THAT IS YET
TO BE INSTALLED, CONTRACTOR SHALL INSTALL SIGN ON A TELSPAR POST ADJACENT TO THE
ULTIMATE LOCATION, AT A SPOT THAT DOESN'T OBSTRUCT THE INSTALLATION. WHEN THE
DEVICE IS INSTALLED, CONTRACTOR SHALL REMOVE AND SALVAGE THE TELSPAR POST AND
RE-INSTALL THE SIGN ON THE DEVICE AT THE ULTIMATE LOCATION AS SHOWN ON THE PLANS.
11.CONTROL POINTS OR 'CAT TRACKING' SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO
APPLICATION OF PAVEMENT STRIPING AND LEGENDS. TRAFFIC LOOPS SHALL NOT BE CUT IN
PRIOR TO APPROVAL OF CAT TRACKING. A 48 HOUR ADVANCE NOTICE IS REQUIRED FOR
REVIEW OF CAT TRACKING.
12.EXISTING MARKINGS NOT IDENTIFIED AS TO BE REMOVED, REPLACED, OR REFRESHED SHALL BE
REFRESHED WITHIN UP TO 100' OF THE PROJECT LIMITS AT THE DISCRETION OF THE CITY'S
INSPECTOR OR TRAFFIC ENGINEER.
13.BLUE RAISED PAVEMENT MARKERS SHALL BE INSTALLED AT ALL FIRE HYDRANT LOCATIONS PER
CITY DESIGN STANDARD 6001.
14.RECORD DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD,
WHO SHALL PROVIDE RECORD DRAWINGS AND ELECTRONIC AUTOCAD FILES TO THE CITY
ENGINEER.
17 APPLY 6" DOUBLE YELLOW STRIPING WITH REFLECTIVE
MARKERS PER CALTRANS DET. 29.
09/16/2026
DWG 6356
9/16/2026
TPC24-00163