Loading...
HomeMy WebLinkAbout6356-1E T E 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 CY P R E S S A V E N U E VALLEY BOULEVARD L = 50' L = 50' 1 12 ' 12 ' VA R 11 ' 12 ' 12 ' VA R 15'12'12'12'12' 13 ' 12 ' 13 ' 12 ' VA R VA R VAR 11'11'13'5'12' 8 8 33 (1 3 ' ) (1 2 ' ) 111111 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 EX S T . R / W EXIST. BUS STOP EXIST. DWY NE W RA I S E D ME D I A N EXIST. R26(S)(CA) W9-1 13 13 13 7 7 11 11 11 16 TYPE VI (L)TYPE VI (L) 6NEW R4-7 +OM2-H1 W4-2 5 4 CONSTRUCTION C/L SURVEY C/L 4 5 240' 5 7 7 R4-1 70 ' R28(S)(CA)10 13 FH FH FH 66 ' 67 ' 54 ' 55 ' FH 15 ' R28(S)(CA)10 EXIST. R2-1(45) 12 12 12 12 12 JOIN EX. STRIPING END TAPER STA 14+44.67 L=280' SHIFTING TAPER (65:1 RATIO)@4.3' SHIFT 17+00 18+00 19+00 20+00 21+00 22+00 23+00 23+20 VALLEY BOULEVARD 1 17+00 18+00 19+00 20+00 21+00 22+00 23+00 23+20 L=50' L=50'1 EX I S T . R / W PR O P . R / W EX S T . R / W EX S T . R / W EXIST. DWY EXIST. DWY EXST. R/W NE W S I D E W A L K 12 ' 12 ' VA R VA R 12 ' VA R (1 3 ' ) 3 11 TYPICAL 14 ' 13 ' VA R 12 ' VA R VA R (1 3 ' ) 13 EXIST. R26(S)(CA) EXIST. R9-3 EXIST. R3-1 R26(S)(CA) 3 1111 3 TYPE VI (L) R4-7 +OM2-H1 TYPE IV (L) 6 JU N I P E R A V E CONSTRUCTION C/L PROTECT EXIST. R3-1 SURVEY C/L 9 9 5 4 4 6 NE W R A I S E D ME D I A N FH FH 13 66 ' 67 ' 54 ' 55 ' 15 ' FH 13 3TYPE VI (L) 7 7 7 7 2 L=251' R3-1 +"TRUCKS" L=50'11 11 114 14 ' 12 ' 12 ' 12 ' 12 ' 13 ' 17 ' 4' FH NE W C U R B & G U T T E R NE W S I D E W A L K NE W C U R B & G U T T E R R28(S)(CA)10 R28(S)(CA)10 20+00 19 + 0 0 8.0' 11'11'VAR TYPE VII (R) 15 14 11 11 1111 11 L=360' SHIFTING TAPER (45:1 RATIO)@8' SHIFT BEGIN TAPER STA. 22+18.47END TAPER STA. 18+58.47 BEGIN TAPER STA. 17+24.67 2 14 L= 1 0 0 ' 11 21 + 0 0 22 + 0 0 23 + 0 0 EXST. R/W BEGIN TAPER (AT DRIVEWAY BCR) STA. 23+22.00 END TAPER STA. 21+72.00 15 L= 1 5 0 ' S H I F T I N G T A P E R ( 2 5 : 1 R A T I O ) @ 6 ' S H I F T BEGIN TAPER STA. 22+82.00 4 L=110' SHIFTING TAPER (110:1 RATIO) @1' SHIFT END TAPER STA. 21+72.00 17 L=110' SHIFTING TAPER (55:1 RATIO) @2' SHIFT 2 17 13 R28L(S)(CA)PR O P . R / W EX I S T . R / W EX I S T . R / W JUNIPER AVENUE 65 . 0 ' 32 . 0 ' 33 . 0 ' 12 ' VA R VA R NEW DWYNEW DWY EXIST. DWY EXSIT. DWY EXIST. R26(S)(CA)EXIST. R26(S)(CA) EXIST. R26(S)(CA) R26(S)(CA) R5-2+R20D-1(CA)(5) R5-2+R20D-1(CA)(5) 5 6 5 6 R28R(S)(CA)10 R26(S)(CA)5 R28LR(S)(CA)6 12 12 12 12 12+00 13+00 14+00 15+00 16+00 17+00 18+00 13 FH 13 FH FH GRAPHIC SCALE SCALE: 1" = 0 40'80' 40' 20'40' MA T C H L I N E S T A 1 7 + 0 0 SE E B E L O W A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT BEFORE YOU DIG TOLL FREE DIAL DAYS BEFORE 1-800-422-4133 TWO WORKING YOU DIG REV.REVISION DESCRIPTION ENGR.DATE CITY DATE CHECKED BY: DESIGNED BY: AND CARRIED FORTH IN A DILIGENT MANNER, THE STANDARDS IN EFFECT. PLANS TO BRING THEM INTO CONFORMANCE WITH CITY ENGINEER MAY REQUIRE REVISIONS TO THE IMPROVEMENTS NOT COMMENCE WITHIN TWO SHOULD CONSTRUCTION OF THE REQUIRED YEARS OF THE DATE OF APPROVAL SHOWN HEREON Prepared Under The Supervision Of : Date: DRAWN BY: 1 CITY OF FONTANA, CALIFORNIA APPROVED BY:DRAWING NO.: 6356 DATE: SCALE: SIGNING AND STRIPING PLAN PM 20669 VALLEY BOULEVARD AND JUNIPER AVENUE GIA LAM KIM DATE: AS SHOWN NT NT DC 5/20/2026 DAVID J. CURTIS R.C.E. 75791 BASIS OF BEARINGS BENCH MARK: CITY OF FONTANA BENCHMARK THE BASIS OF BEARINGS FOR THIS SURVEY IS THE CALIFORNIA STATE PLANE COORDINATE SYSTEM, ZONE 5, CONSTRAINED LOCALLY BETWEEN CONTINUOUS GPS STATIONS EWPP & RTHS. SAID BEARING IS S84°19'30"E (NAD83(2011) 2017.50 EPOCH.) GPS CONTINUOUS OPERATING REFERENCE STATION EWPP. THE ANTENNA IS AN ASHTECH 701945B_M W/SCIT DOME. TRUE VERTICAL ANTENNA HEIGHT IS FROM THE GEODETIC REFERENCE POINT TO THE BOTTOM OF THE ANTENNA PRE-AMP(BPA) AND IS 0.027 FEET. ELEVATION = 1194.52 R.C.E. 62296 CITY ENGINEER 1650 SPRUCE STREET, SUITE 400 RIVERSIDE, CA 92507 951.787.8421 www.psomas.com 1 No. C75791REGISTERED P ROFESSIONAL E N G I N E ER S T A TE OF CA L I F O R NIA CI V I L DAV I D J . CU R T I S 5/20/26 TPC24-00163 MA T C H L I N E S T A 1 7 + 0 0 SE E A B O V E R2-1 SPEED LIMIT R4-1 DO NOT PASS R28LR(S)(CA) NO STOPPING ANY TIME R3-1 NO RIGHT TURN W4-2 RIGHT LANE ENDS W9-1 RIGHT LANE ENDS TRUCKS R4-7 MEDIAN OM2-1H TYPE K-1 MATCHLINE STA 18+90 SEE BELOW MA T C H L I N E S T A 1 8 + 9 0 SE E A B O V E R5-2 NO TRUCKS R20D-1(CA)(5) 5 TONS CONSTRUCTION NOTES ITEM DESCRIPTION 1 APPLY THERMOPLASTIC 6" WHITE LANE LINE (TYP 50') 2 3 APPLY ARROW LEGEND AS SHOWN ON PLAN 4 5 REMOVE EXISTING SIGN AND POST 6 9 FURNISH AND INSTALL SIGN ON STREET LIGHT POLE 11 REFRESH EXISTING STRIPING/ MARKINGS AS NECESSARY12 10 REMOVE STRIPING/LEGENDS COMPLETE 8 APPLY PAVEMENT LEGEND AS SHOWN ON PLAN FURNISH AND INSTALL NEW SIGN AND POST AS SHOWN 13 7 SIGNING AND STRIPING GENERAL NOTES: CITY OF FONTANA SIGNING AND STRIPING PLAN VALLEY BOULEVARD AND JUNIPER AVENUE PARCEL MAP NO. 20669 APPLY THERMOPLASTIC 6" WHITE DASHED LANE LINES PER CALTRANS DETAIL 12A APPLY THERMOPLASTIC CHANNELIZING STRIPE PER CALTRANS DETAIL 38 INSTALL BLUE RPM MARKER FOR HYDRANT LOCATION AT 6" OFF CURB OR LEFT-EDGE STRIPE APPLY THERMOPLASTIC 12" WHITE CROSSWALK APPLY THERMOPLASTIC 6" YELLOW STRIPING PER CALTRANS DET. 25A OVER SIGN SIZE(INCHES) SIGN TYPE & SIZE SIGN DESIGNATION 30x36 24x30 12x18 24x24 36x36 36x36 24x30 24x24 12X6 24x6 24x6 14 APPLY 8" DIAGONAL STRIPING SPACED 30' C-C. 15 APPLY 6" WHITE STRIPING PER CALTRANS DET. 27B. R26(S)(CA) NO STOPPING ANY TIME 12X18 16 APPLY THERMOPLASTIC CHANNELIZING STRIPE PER CALTRANS DETAIL 38A R28R(S)(CA) NO STOPPING ANY TIME 12x18 R28L(S)(CA) NO STOPPING ANY TIME 12x18 1.ALL WORK, MATERIALS, EQUIPMENT AND TEMPORARY TRAFFIC CONTROL SHALL CONFORM TO THESE PLANS, THE CITY OF FONTANA DESIGN STANDARDS, THE CITY'S SPECIAL PROVISIONS, SECTION E, CALTRANS STAND PLANS AND SPECIFICATIONS, AND THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES, LATEST EDITIONS. 2.ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA DEPARTMENT OF ENGINEERING PRIOR TO COMMENCEMENT OF WORK. 3.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAINTAIN TEMPORARY TRAFFIC CONTROL AT ALL TIMES. 4.ALL SIGNS SHALL BE INSTALLED PER CITY DESIGN STANDARD 4003, UNLESS OTHERWISE SPECIFIED ON THE PLANS. SIGNS AND SIGNPOSTS THAT ARE REMOVED SHALL BE SALVAGED TO THE CITY YARD AT 16489 ORANGE WAY. 5.ALL STRIPING SHALL BE ALKYD THERMOPLASTIC UNLESS OTHERWISE NOTED. STRIPING AND PAVEMENT LEGENDS SHALL BE APPLIED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS. 6.ON ROADWAYS WITH RAISED MEDIANS, SUBSTITUTE TYPE "C" RAISED PAVEMENT MARKERS FOR TYPE "G" MARKERS ON DETAIL 38 AND 37B STRIPING. 7.STRIPING AND PAVEMENT MARKINGS TO BE REMOVED SHALL BE REMOVED BY SANDBLASTING OR OTHER APPROVED METHOD, NONE OF WHICH SHALL DAMAGE THE PAVEMENT. THE 'BLACK OUT' METHOD OF REMOVAL IS NOT PERMITTED. ANY PAVEMENT DAMAGED BY REMOVALS SHALL BE REPAIRED PER APPROVAL BY THE CITY ENGINEER AT NO COST TO THE CITY. 8.PARKING RESTRICTIONS (RED CURB, SIGNAGE) SHALL BE INSTALLED ONE WEEK PRIOR TO INSTALLATION OF STRIPING. 9.ALL STRIPING AND SIGNS (OTHER THAN PARKING RESTRICTION SIGNS) SHALL BE APPLIED/INSTALLED AT THE SAME TIME. 10.IF SIGNS ARE TO BE PLACED ON A DEVICE (SUCH AS A STREET LIGHT POLE) THAT IS YET TO BE INSTALLED, CONTRACTOR SHALL INSTALL SIGN ON A TELSPAR POST ADJACENT TO THE ULTIMATE LOCATION, AT A SPOT THAT DOESN'T OBSTRUCT THE INSTALLATION. WHEN THE DEVICE IS INSTALLED, CONTRACTOR SHALL REMOVE AND SALVAGE THE TELSPAR POST AND RE-INSTALL THE SIGN ON THE DEVICE AT THE ULTIMATE LOCATION AS SHOWN ON THE PLANS. 11.CONTROL POINTS OR 'CAT TRACKING' SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO APPLICATION OF PAVEMENT STRIPING AND LEGENDS. TRAFFIC LOOPS SHALL NOT BE CUT IN PRIOR TO APPROVAL OF CAT TRACKING. A 48 HOUR ADVANCE NOTICE IS REQUIRED FOR REVIEW OF CAT TRACKING. 12.EXISTING MARKINGS NOT IDENTIFIED AS TO BE REMOVED, REPLACED, OR REFRESHED SHALL BE REFRESHED WITHIN UP TO 100' OF THE PROJECT LIMITS AT THE DISCRETION OF THE CITY'S INSPECTOR OR TRAFFIC ENGINEER. 13.BLUE RAISED PAVEMENT MARKERS SHALL BE INSTALLED AT ALL FIRE HYDRANT LOCATIONS PER CITY DESIGN STANDARD 6001. 14.RECORD DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS AND ELECTRONIC AUTOCAD FILES TO THE CITY ENGINEER. 17 APPLY 6" DOUBLE YELLOW STRIPING WITH REFLECTIVE MARKERS PER CALTRANS DET. 29. 09/16/2026 DWG 6356 9/16/2026 TPC24-00163