HomeMy WebLinkAbout6064LT-1DATE:
SCALE:
DRAWING NO.
DATE
APPROVED BY:CHECKED BY:
DESIGNED BY:
DRAWN BY:
CITY ENGINEER R.C.E. 51152
CITY OF FONTANA, CALIFORNIADATECITYENGR.DATEREVISION DESCRIPTIONREV.
SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT
COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN
HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY
ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM
INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT.DATE:
PREPARED UNDER THE SUPERVISION OF:
STEVEN L. ELLIS EXP. 12-31-21
STREET LIGHT PLAN
6064LT 3
APR. 2021
AS SHOWNHD
-
SE
BENCH MARK:BASIS OF BEARINGS:
THE BEARINGS SHOWN HEREON ARE BASED THE ON NORTH AMERICAN
DATUM OF 1983 (NAD-83), SHOWN IN TERMS OF THE CALIFORNIA
COORDINATE SYSTEM OF 1983 (CCS-83), ZONE V (2011.00 EPOCH DATE)
AS DERIVED BY POSITIONS PUBLISHED BY CSRC. ALL COORDINATE
VALUES WERE SCALED TO GROUND BY APPLYING AN AVERAGE
COMBINATION FACTOR AS DETERMINED BY FEI POINTS 11012, 11014,
11022, 11025, 11029, AND 11034 AND HOLDING THE COMPUTED GRID
COORDINATE ON POINT 11015. INVERSES BETWEEN PROJECT
COORDINATES WILL PRODUCE GROUND DISTANCES. TO OBTAIN GRID
DISTANCES MULTIPLY GROUND DISTANCES BY 0.999888867
THE CONTOURS AND ELEVATIONS SHOWN HEREON
ARE BASED ON THE FOLLOWING BENCH MARK:
BM NO.: EV9274 ELEV.: 1508.56' (NGS BENCH MARK)
DATUM: NAVD 88 1993 ADJ GNIREENEIGN
2850 Inland Empire Blvd., Suite B, Ontario, California 91764
tel 909.581.0676 fax 909.581.0696 www.fuscoe.com
1
CITY OF FONTANA
STREET LIGHT PLANS 15
VICINITY MAP
SITE
SHEET INDEX MAP
SHEET 2
STREET LIGHT CONSTRUCTION NOTES:
CN DESCRIPTION QUANTITIES UNIT
INSTALL DECORATIVE LED STREET LIGHT - SCE # 10184043 (165WATTS) PER CITY STD. PLAN
NO. 404, CASE 1; CARPINTERIA POLE AND TEARDROP FIXTURE.12 EA.1
SHEET 2
SH
E
E
T
3
TITLE SHEET
QUANTITIES SHOWN HEREON ARE PROVIDED FOR PERMIT AND BONDING PURPOSES ONLY. CONTRACTOR SHALL BE
RESPONSIBLE FOR DETERMINING THEIR OWN QUANTITIES PRIOR TO BIDDING AND CONSTRUCTION. THE ENGINEER IS NOT
RESPONSIBLE FOR DISCREPACIES IN FINAL CONSTRUCTION QUANTITIES.
SHEET INDEX
SHT. NO.DESCRIPTION
1 TITLE SHEET
2 DUNCAN CANYON ROAD
3 CITRUS AVENUE
ENGINEER:
FUSCOE ENGINEERING INC.
2850 INLAND EMPIRE BOULEVARD, SUITE B
ONTARIO, CALIFORNIA 91764
(909) 581-0676
ELECTRIC:
SOUTHERN CALIFORNIA EDISON COMPANY
7951 REDWOOD AVENUE
FONTANA, CA 92336
PHONE: 909.357.6221
NATURAL GAS:
THE GAS COMPANY, SEMPRA UTILITIES
16231 VALLEY BLVD.
FONTANA, CA 92235
PHONE: 800.427.2200, 909.428.8411
WATER:
WEST VALLEY DISTRICT
855 W. BASELINE ROAD
RIALTO, CA 92377
PHONE: 909.875.1361
SEWER:
CITY OF FONTANA
8353 SIERRA AVENUE
FONTANA, CA 92235
PHONE: 909.350.6632
SEWER TREATMENT FACILITIES
INLAND EMPIRE UTILITY AGENCY
12645 6TH STREET
RANCHO CUCAMONGA, CA 91739
PHONE: 909.947.4131
SOLID WASTE:
BURRTEC WASTE
9454 CHERRY AVENUE
FONTANA, CA 92335
PHONE: 909.822-9739
TELEPHONE:
AT&T
11464 TELEGRAPH ROAD
SANTA FE SPRINGS, CA 90670
PHONE: 714.666.5415
CABLE SERVICES:
TIME WARNER CABLE
1205 DUPONT AVENUE
ONTARIO, CA 91761
PHONE: 909.390.4738
CITY OF FONTANA UTILITY NOTIFICATION LIST:
STREET GENERAL NOTES:
1.LIGHTING LAYOUT SHALL COMMENCE AT STREET INTERSECTIONS. STREET LIGHT SPACING
BETWEEN INTERSECTIONS SHALL BE AS SPECIFIED IN THE TABLE ON SHEET 3 AND LOCATED AT
THE PROLONGATION OF PROPERTY LINES. STREET LIGHT LAYOUT SHALL BE REVIEWED FOR
CONFLICTS WITH OTHER UTILITIES (CATCH BASINS, FIRE HYDRANTS, TRANSFORMERS, ETC.)
2.USE OF BRAND NAMES IN THESE STANDARDS IS NOT INTENDED TO RESTRICT COMPETITION.
EQUIVALENT PRODUCTS MAY BE SUBSTITUTED WITH THE APPROVAL OF THE CITY ENGINEER.
3.SIDEWALK WIDTHS TO BE PER APPROVED STREET IMPROVEMENT PLANS. A MINIMUM OF 4'
UNOBSTRUCTED SIDEWALK CLEARANCE IS REQUIRED.
4.ANY CHANGE IN LOCATION OF STREET LIGHTS FROM THE APPROVED PLANS OR STANDARDS IS
SUBJECT TO WRITTEN APPROVAL BY THE CITY ENGINEER.
5.ALL STREET LIGHTS SHALL HAVE AN ANTI-GRAFFITI COATING.
GENERAL NOTES:
1.CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA DEPARTMENT OF ENGINEERING
PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO
WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL
(909) 350-7610.
2.ALL WORK, MATERIALS, EQUIPMENT AND TEMPORARY TRAFFIC CONTROLS SHALL CONFORM TO THESE
PLANS, THE CITY OF FONTANA STANDARD SPECIFICATIONS, THE CITY'S SPECIAL PROVISIONS, SECTION E,
THE STANDARD PLANS AND SPECIFICATIONS OF THE STATE OF CALIFORNIA, DATED 2018, AND THE
CALIFORNIA MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES, DATED 2014.
3.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN TEMPORARY TRAFFIC CONTROL AT ALL
TIMES.
4.ALL SIGNS SHALL BE INSTALLED PER CITY STANDARD DETAIL 4003, UNLESS OTHERWISE SHOWN ON THE
PLANS.
5.BLUE RAISED PAVEMENT MARKERS SHALL BE INSTALLED AT ALL FIRE HYDRANT LOCATIONS PER CITY
STANDARD PLANS.
6.AS-BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL
PROVIDE RECORD DRAWINGS AND ELECTRONIC AUTOCAD FILES TO THE CITY ENGINEER.
PRIVATE ENGINEER'S NOTICE TO CONTRACTORS:
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF
AVAILABLE RECORDS; TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE
CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT
SHOWN ON THESE DRAWINGS.
THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE
OF CONSTRUCTION OF THIS PROJECT; INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS SHALL APPLY CONTINUOUSLY AND NOT BE
LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE ENGINEER
HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING
FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER.
CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE
COMMENCEMENT OF ANY WORK. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE ENGINEER OF ANY DISCREPAN
BEGINNING OF WORK MEANS ACCEPTANCE OF CONDITIONS.
CONTRACTOR SHALL COMPLY WITH ALL N.P.D.E.S. REQUIREMENTS.
CONTRACTOR SHALL ADJUST TO FINISH GRADE ALL MANHOLE RIMS, WATER VALVE BOXES, UTILITY BOXES AND LIDS, ETC.
CONTRACTOR SHALL PROVIDE ALL THE NECESSARY PIPE FITTINGS TO COMPLETE THE WORK.
THE ENGINEER PREPARING THESE PLANS SHALL NOT BE HELD RESPONSIBLE OR LIABLE FOR UNAUTHORIZED CHANGES TO OR USES THESE
PLANS. ALL CHANGES TO THESE PLANS MUST BE REQUESTED IN WRITING AND MUST BE APPROVED BY THE ENGINEER OF RECORD.
OWNER DEVELOPER:
FRONTIER COMMUNITIES
2851 E. CONVENTION CENTER WAY, SUITE 114
ONTARIO, CALIFORNIA 91764
PHONE: 909.354.8040
CONTACT: TIM NGUYEN PROJECT MANAGER
GEOTECHNICAL:
GEO TEK, INC.
1548 NORTH MAPLE STREET
CORONA, CA. 92880
PHONE: (951) 710-1160
PROJECT NO. 2541-CR
SOIL REPORT DATED: OCTOBER 16, 2020
CONTACT: ANNA M. SCOTT - PROJECT GEOLOGIST
DUNCAN CANYON RD. & CITRUS AVE.
TRACT NO.
20224
DUNCAN CANYON RD. & CITRUS AVE.
LEGEND & ABBREVIATIONS
A.C., AC ASPHALT CONCRETE
AC.ACRE
A.B.AGGREGATE BASE
BC BEGIN OF CURVE
BCR BEGIN OF CURB RETURN
BVC BEGIN VERTICAL CURVE
CF CURB FACE
CB CATCH BASIN
C/G CURB & GUTTER
C/L, CL, CENTER LINE
CONC.CONCRETE
CY CUBIC YARD
DW, W DOMESTIC WATER, WATER
DWY DRIVEWAY
E.A., EA EACH
EC END OF CURVE
ECR END OF CURB RETURN
EG EXISTING GROUND
EL., ELEV ELEVATION
EP EDGE OF PAVEMENT
ESMT.EASEMENT
EVC END VERTICAL CURVE
EX., EXIST.,(E)EXISTING
FH FIRE HYDRANT
FG FINISH GRADE
FL FLOWLINE
FS FINISHED SURFACE
FW FIRE WATER
GB GRADE BREAK
HP HIGH POINT
INV INVERT
JT., JNT.JOINT
L LENGTH
L.F., LF LINEAL FEET
L.S.LUMP SUM
LT LEFT
MAX MAXIMUM
MIN MINIMUM
MH MANHOLE
(N)NEW
N.T.S., NTS NOT TO SCALE
PCC POINT OF COMPOUND CURVE
P.C.C.PORTLAND CEMENT CONCRETE
PI POINT OF INTERSECTION
PRC POINT OF REVERSE CURVE
P/L, PL PROPERTY LINE
P.O.C.POINT OF CONNECTION
PP POWER POLE
PROP.PROPOSED
P.U.E.PUBLIC UTILITY EASEMENT
PVC POLYVINYL CHLORIDE PIPE
PVT PRIVATE
RT RIGHT
RCB REINFORCED CONCRETE BOX
RCP REINFORCED CONCRETE PIPE
R/W RIGHT OF WAY
RW RETAINING WALL
SCE SOUTHERN CALIFORNIA EDISON
SD STORM DRAIN
S=SLOPE
S, SW, SS SEWER, SANITARY SEWER
SIM.SIMILAR
SF, S.F.SQUARE FEET
STA STATION
TC TOP OF CURB
TYP., TYP TYPICAL
W, DW WATER, DOMESTIC WATER
VCP VITRIFIED CLAY PIPE
CENTERLINE
PROPERTY LINE
RIGHT OF WAY
EXISTING EASEMENT
x1790.3 EXISTING SPOT ELEVATION
EXISTING CONTOUR
PROPOSED CONTOUR
DAYLIGHT LINE
EXISTING SEWER
EXISTING RECLAIMED WATER
EXISTING WATER
EXISTING GAS
EXISTING STORM DRAIN
EXISTING FIRE HYDRANT
EXISTING POWER POLE
PROPOSED WATER
PROPOSED STORM DRAIN
SEWER OR STORM DRAIN MANHOLE
CATCH BASIN
FLOW ARROW & GRADE
GRADED SWALE
PROPOSED STREET LIGHT
TOP OF SLOPE
TOE OF SLOPE
AC PAVEMENT
CONCRETE PAVEMENT
PROPOSED CURB & GUTTER
PUBLIC UTILITY EASEMENT
PROPOSED FIRE HYDRANT
PROPOSED RETAINING WALL
8-3-21
8/18/2021
5/11/26REMOVE EXIST. STREET LIGHTS 3 EA SE1
9 1
XP 6/11/26