Loading...
HomeMy WebLinkAbout6573-LT16 " W 10 " W 16 " W 10 " W 16 " W 16 " W 48 " D 48 " D 4" S F M 4" S F M CO M M CO M M 1 6"D 6"D 6"D 10"F 10"F 16+56 13+92 2 2 18 + 0 0 17 + 0 0 16 + 0 0 15 + 0 0 14 + 0 0 13 + 0 0 PROP. R/W EXIST. R/W EXIST. R/W (N)41W (N)41W PROP. R/W JU N I P E R A V E N U E 15+12 EX. STREET LIGHT 17+95 EX. STREET LIGHT 2'-0" (UNK) 12"W 8"W 8"W 8"W 12"W 10 " W 16 " W 16 " W 10 " W 16 " W 16 " W 12"W 12"S 21"S 24"D 36"D 21"S 12"SS SS SS 4" S F M 4" S F M TS COMMTS COMM TS 48 " D D SD SD SS SD SD SS SD E SS SD SD SS SSSS IW 2" W 6"D 6"D6" D 6" D IW 4" W IW 10 " W 10 " F 10 " F 8" S8" S 24"D 24"D24"D 6" D 10"F 10 " F 17 + 9 5 20 + 5 5 1 1 17+00 18+00 19+00 20+00 21+00 22+00 23+00 20 + 0 0 19 + 0 0 PROP. R/W EXIST. R/W EXIST. R/W PROP. R/W EXIST. R/W EXIST. R/W (N ) 9 0 W (N ) 9 0 W (N ) 9 0 W VALLEY BOULEVARD JU N I P E R A V E N U E 21 + 2 2 EX . S T R E E T L I G H T 19 + 9 0 EX . S T R E E T L I G H T 18 + 5 3 EX . S T R E E T L I G H T 17 + 6 2 EX . S T R E E T L I G H T 19 + 2 1 1 22+72 EX. SAFETY LIGHT PER TRAFFIC SIGNAL PLAN 19+25 EX. SAFETY LIGHT PER TRAFFIC SIGNAL PLAN 22 + 5 9 EX . S A F E T Y L I G H T 16 + 6 2 EX . S T R E E T L I G H T INTERSECTION EQUATION VALLEY BLVD: 23+19.52 JUNIPER AVE: 20+00.00 66 ' 15 ' CONSTRUCTION CENTERLINE RECORD CENTERLINE SLOVER AVE BOYLE AVE VALLEY BLVD SI E R R A A V E JU N I P E R A V E CY P R E S S A V E OL E A N D E R A V E VALLEY BLVD MARYGOLD AVE SLOVER AVEJU N I P E R A V E SAN BERNARDINO F W Y INTERSTATE 10 WASHINGTON DRIVE PM 20669 12"W S 12"S 12"S S 18 " D S 18" D 18 " D (N ) 4 1 W 1 16 + 5 3 WASHINGTON DRIVE DR I V E W A Y EXIST. R/W PROP. R/W 16+00 17+00 1.THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY SEARCH OF ALL AVAILABLE RECORDS. THESE LOCATIONS ARE APPROXIMATE AND SHALL BE CONFIRMED BY A CONTRACTOR, SO THAT ANY NECESSARY ADJUSTMENT CAN BE MADE IN ALIGNMENT AND/OR GRADE OF THE PROPOSED IMPROVEMENT. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT ANY UTILITY LINES SHOWN OR NOT SHOWN ON THESE PLANS. 2.CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY. THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD CITY OF FONTANA HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTION LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF DESIGN PROFESSIONAL. 3.ALL CONTRACTORS AND SUBCONTRACTORS SHALL COMPLY WITH THE "OCCUPATIONAL SAFETY AND HEALTH REGULATIONS" OF THE US DEPARTMENT OF LABOR AND WITH THE STATE OF CALIFORNIA DEPARTMENT OF INDUSTRIAL RELATIONS "CONSTRUCTION SAFETY ORDERS". THE CITY OF FONTANA SHALL NOT BE RESPONSIBLE IN ANY WAY FOR THE CONTRACTOR OR SUBCONTRACTORS COMPLIANCE WITH SAID REGULATIONS AND ORDERS. 4.UNAUTHORIZED CHANGES & USES: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE OR LIABLE FOR UNAUTHROIZED CHANGES TO OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE ENGINEER PREPARING THESE PLANS. NOTICE TO CONTRACTOR: 1.ORNAMENTAL STREET LIGHT POLES SHALL BE MARBLELITE OR APPROVED EQUAL. 2.THE LUMINAIRE SHALL CONSIST OF COBRA HEAD CUT-OFF LENS ON A 6 FEET OR 8 FEET MAST ARM. 15 FEET MAST ARM ARE REQUIRED FOR STREETLIGHTS ON TRAFFIC SIGNAL POLE INSTALLATIONS. 3.ANY SUBJECT IN LOCATION OF STREETLIGHTS FROM THE APPROVED PLANS IS SUBJECT TO APPROVAL BY THE CITY ENGINEER. 4.SIDEWALK WIDTHS TO BE APPROVED PER STREET IMPROVEMENT PLANS. A MINIMUM OF 4 FEET UNOBSTRUCTED SIDEWALK CLEARANCE IS REQUIRED. 5.CONTRACTOR SHALL COORDINATE WITH SCE LOCAL PLANNER (TELEPHONE: 800-655-4555) A MINIMUM OF (7) WORKING DAYS PRIOR TO WORKING ON ANY ELCTROLIER. GENERAL NOTES: VICINITY MAP NOT TO SCALE PROJECT SITE MATCHLINE STA. 18+50 SEE ABOVE RIGHT MATCHLINE STA. 18+50 SEE BELOW LEFT INSTALL AMERON POLE NO. 1C1-28 STANDARD LED STREET LIGHT WITH COBRAHEAD LUMINAIRE 10205811 (90W) PER CITY OF FONTANA STD PLAN NO. 1017 CASE 1 INSTALL AMERON POLE NO. 1C1-28 STANDARD LED STREET LIGHT WITH COBRAHEAD LUMINAIRE 10205809 (41W) PER CITY OF FONTANA STD PLAN NO. 1017 CASE 3 CONSTRUCTION NOTES: 4 EA. 2 EA. QUANTITIES: EXISTING RIGHT OF WAY PROPOSED RIGHT OF WAY CENTERLINE EXISTING POLE AND LUMINAIRE PROPOSED POLE AND 41W LED LUMINAIRE PROPOSED POLE AND 90W LED LUMINAIRE LEGEND: UTILITY NOTIFICATIONS: WATER:............FONTANA WATER COMPANY...........(909) 201-7312 SEWER:............CITY OF FONTANA.............................(909) 350-7610 ELECTRICITY:..SOUTHERN CALIFORNIA EDISON...(800) 611-1911 GAS:.................SOCAL GAS.........................................(800) 423-1391 COMM:.............AT&T.....................................................(800) 332-1321 COMM:.............SPECTRUM..........................................(844) 708-0654 THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE PLANS WAS OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. ADDITIONAL UNDERGROUND FACILITIES MAY EXIST, OR THE LOCATION OF FACILITIES MAY DIFFER FROM THE LOCATIONS SHOWN ON THE PLANS. THE CONTRACTOR SHALL AT HIS OWN EXPENSE DETERMINE THE EXACT LOCATION OF ALL SUCH UNDERGROUND UTILITIES PRIOR TO DOING ANY WORK OR TAKING ANY ACTION THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR CONTINUOUS OPERATIONS UPON LEARNING OF THE EXISTENCE AND LOCATION OF ANY UNDERGROUND FACILITIES NOT SHOWN ACCURATELY ON THESE PLANS OR NOT PROPERLY MARKED BY THE UTILITY OWNER. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE UTILITY OWNER AND THE ENGINEER BY TELEPHONE AND IN WRITING. POTHOLE VERIFICATION: 1 (N)41W (N)90W A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT BEFORE YOU DIG TOLL FREE DIAL DAYS BEFORE 811 TWO WORKING YOU DIG REV.REVISION DESCRIPTION ENGR.DATE CITY DATE CHECKED BY: DESIGNED BY: AND CARRIED FORTH IN A DILIGENT MANNER, THE STANDARDS IN EFFECT. PLANS TO BRING THEM INTO CONFORMANCE WITH CITY ENGINEER MAY REQUIRE REVISIONS TO THE IMPROVEMENTS NOT COMMENCE WITHIN TWO SHOULD CONSTRUCTION OF THE REQUIRED YEARS OF THE DATE OF APPROVAL SHOWN HEREON Prepared Under The Supervision Of : Date : DRAWN BY: 1 CITY OF FONTANA, CALIFORNIA APPROVED BY:DRAWING NO.: 6573-LT 1 DATE: SCALE: STREET LIGHTING PLAN DATE: AS SHOWN DDP DDP NN STREET LIGHTING PLAN CITY OF FONTANA 11/12/2025 ARIEF NAFTALI R.C.E. 64286 BASIS OF BEARINGS BENCH MARK: CITY OF FONTANA BENCHMARKTHE BASIS OF BEARINGS FOR THIS SURVEY IS THE CALIFORNIA STATE PLANE COORDINATE SYSTEM, ZONE 5, CONSTRAINED LOCALLY BETWEEN CONTINUOUS GPS STATIONS EWPP & RTHS. SAID BEARING IS S84°19'30"E (NAD83(2011) 2017.50 EPOCH.) GPS CONTINUOUS OPERATING REFERENCE STATION EWPP. THE ANTENNA IS AN ASHTECH 701945B_M W/SCIT DOME. TRUE VERTICAL ANTENNA HEIGHT IS FROM THE GEODETIC REFERENCE POINT TO THE BOTTOM OF THE ANTENNA PRE-AMP(BPA) AND IS 0.027 FEET. ELEVATION = 1194.52'GIA LAM KIM R.C.E. 62296 CITY ENGINEER S T A TE OF CA L I F O R N IA R EG ISTER E D P R O F ESSIONA L E N G I NEER A R I E F N A F T A L I No. 64286 C I V I LCIVIL 2010 Iowa Avenue, Suite 101 Riverside, CA, 92507 (909) 787-8421 (909) 682-3379 fax www.psomas.com 11/12/2025 VALLEY BOULEVARD, JUNIPER AVENUE AND WASHINGTON DRIVE PARCEL MAP NO. 20669 0' GRAPHIC SCALE I" = 40' 40 4020 80 VALLEY BOULEVARD, JUNIPER AVENUE AND WASHINGTON DRIVE PARCEL MAP #20669 EXP. 6/30/2027 MCN22-000145 / ELPC24-00109 1.LIGHTING LAYOUT SHALL COMMENCE AT STREET INTERSECTIONS. STREET LIGHT SPACING BETWEEN INTERSECTIONS SHALL BE AS SPECIFIED ON THE PLAN AND LOCATED AT THE PROLONGATION OF PROPERTY LINES. STREET LIGHT LAYOUTS SHALL BE REVIEWED FOR CONFLICTS WITH OTHER UTILITIES (CATCH BASINS, FIRE HYDRANTS, TRANSFORMERS, ETC.) 2.STREET LIGHTS SHALL BE PLACED AT ALL INTERSECTION AND CUL-DE-SACS. 3.STREET LIGHTS HAVE A MINIMUM 1' CLEARANCE FROM OTHER UTILITIES AND A MINIMUM 5' CLEARANCE FROM THE OUTSIDE EDGE OF DRIVEWAY WINGS. 4.USE OF BRAND NAMES IN THESE STANDARDS IS NOT INTENDED TO RESTRICT COMPETITION. EQUIVALENT PRODUCTS MAY BE SUBSTITUTED WITH THE APPROVAL OF THE CITY ENGINEER. 5.SIDEWALK WIDTHS TO BE PER APPROVED STREET IMPROVEMENT PLANS. A MINIMUM OF 4' UNOBSTRUCTED SIDEWALK CLEARANCE IS REQUIRED. 6.ANY CHANGE IN LOCATION OF STREET LIGHTS FROM THE APPROVED PLANS OR STANDARDS IS SUBJECT TO WRITTEN APPROVAL BY THE CITY ENGINEER. 7.ALL STREET LIGHTS SHALL HAVE AN ANTI-GRAFFITI COATING. 8.MANHOLE COVERS AND PILLBOXES SHALL BE PLACED EITHER ENTIRELY WITHIN THE SIDEWALK OR PARKWAY. THERE SHALL BE NO OVERLAP. STREET LIGHTING GENERAL NOTES: PRIVATE ENGINEER'S NOTE: THE PRIVATE ENGINEER SIGNING THESE PLANS IS RESPONSIBLE FOR ASSUMING THE ACCURACY AND ACCEPTABILITY OF THE WORK HERE ON. IN THE EVENT OF DISCREPANCIES ARISING DURING CONSTRUCTION THE PRIVATE ENGINEER SHALL BE RESPONSIBLE FOR DETERMINING AN ACCEPTANCE SOLUTION AND REVISING THE PLANS FOR APPROVAL BY THE CITY. 2 INDEX MAP WASHINGTON DRIVE VALLEY BOULEVARD JU N I P E R A V E N U E PM - 20669 PARCEL 1PARCEL 2 NOT TO SCALE DR I V E W A Y CY P R E S S A V E N U E 2/2/2026