HomeMy WebLinkAbout6792-5B OR C�
SIZE AND SPACING OF STEEL AS SHOWN ON PROJECT
DRAWINGS, EXCEPT THAT 5 BARS ON EACH SIDE OF
SHAFT SHALL BE NOT SMALLER THAN #5 ® 4"
(#16M ® 100 mm) OC OR EQUIVALENT
A
PLAN
(SHAFT NOT SHOWN)
SECTION A - A
MANHOLE FRAME AND
COVER PER SPPWC 630---1 r
MANHOLE SHAFT PER
SPPWC 324
5"x2"(125mm x50mm)
PIPE SEAT
OMIT FILLET
UNDER SHAFT
7" (17
5 ® 4" (#16M ® 100 mm) OC x 5'-0"
1.5 m) LONG
OR C
5 BARS 7'-0" 2.1 m LONG, 4' 100 mm OC,
OF SIZE SHOWN FOR TRANSVERSE STEEL,
BUT NOT SMALLER THAN #5 (#16M� BARS.
WARP THESE BARS UNDE BARS HAT
HAVE BEEN CUT FOR SHAFT OPENING
STREET GRADE I CONCRETE RINGS
PER SPPWC 324
5"x 1" 125 mm x 25 mm)
RING SEAT i
-STREET GRADE
w
M
a
w
w
5"
125m
SECTION B - B
610 m 5"
(125 rr
OMIT FILLET
UNDER SHAFT
7" 175 mm
STEPS
SECTION C - C
TABLE OF VALUES FOR M (SEE NOTE 1)
SECTION
PAVED STREET
UNPAVED STREET
MAX
MIN
MAX
MIN
B - B
-
2'-10 1/2" (867 mm)
-
3'-6" (1060 mm)
C - C
11" (282 mm)
8 1/2" (217 mm)
16"(410 mm)
15" (380 mm)
STANDARD PLANS FOR PUBLIC WORKS CONSTRUCTION
PR MULGATED THE
WORKS
PUBLIC WORKS STANDARDS INC.
MANHOLE CONCRETE
STANDARD PLAN
GREENBO COMMITTEE
BOX STORM DRAIN
323- 2
1992
19
REV. 1996, 2009
SHEET 1 OF 2
USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION
0 = FN
O Q 00 0 Uj
w B
o Uj
� a H
d N + N NO
F H H I- Z _
I
I
A-�-
RCP OR I
RC ARCH* 1
I
I m /
NOTES
1. WHEN DEPTH M FROM STREET GRADE TO THE TOP OF THE BOX IS LESS
THAN 2'-10 1/2" (867 mm) FOR PAVED STREETS OR 3'-6" (1060 mm) FOR
UNPAVED STREETS, CONSTRUCT SHAFT PER SECTION C-C.
2. STATIONS OF MANHOLES SHOWN ON PLANS. APPLY AT CENTERLINE
LINE OF SHAFT. ELEVATIONS ARE SHOWN AT CENTERLINE OF SHAFT.
3. REINFORCEMENT SHALL CONFORM TO ASTM A 615, GRADE 40 (ASTM A
615M, GRADE 300), AND SHALL TERMINATE 40 mm (1 1/2") CLEAR OF CONCRETE
SURFACES UNLESS OTHERWISE SHOWN.
4. STEPS SHALL CONFORM TO SPPWC 635 OR 636. UNLESS OTHERWISE
SHOWN, STEPS SHALL BE UNIFORMLY SPACED 14" (350 mm) TO 15" (375 mm) OC.
THE LOWEST STEP SHALL NOT BE MORE THAN 24" (600 mm) ABOVE THE INVERT.
5. MANHOLE FRAME AND COVER SHALL CONFORM TO SPPWC 630
UNLESS OTHERWISE SHOWN.
6. MANHOLE SHAFT SHALL CONFORM TO SPPWC 324 UNLESS
OTHERWISE SHOWN.
7. WHERE A MANHOLE SHAFT - 36" (900 mm) WITHOUT REDUCER IS SPECIFIED
REFER TO SPPWC 326.
8. WHERE A PRESSURE MANHOLE SHAFT - WITH ECCENTRIC REDUCER IS
SPECIFIED REFER TO SPPWC 328.
9. WHERE A PRESSURE MANHOLE SHAFT - 36" (900 mm) WITHOUT REDUCER
IS SPECIFIED REFER TO SPPWC 329.
10. THE FOLLOWING SPPWC ARE INCORPORATED HEREIN:
324 MANHOLE SHAFT - WITH ECCENTRIC REDUCER
326 MANHOLE SHAFT - 36" (900 mm) WITHOUT REDUCER
328 PRESSURE MANHOLE SHAFT - WITH ECCENTRIC
329 PRESSURE MANHOLE SHAFT - 36" (900 mm) WITHOUT REDUCER
630 24" (600 mm) MANHOLE FRAME AND COVER
633 36" (900 mm) MANHOLE FRAME AND COVER
635 STEEL STEP
636 POLYPROPYLENE PLASTIC STEP
STANDARD PLANS FOR PUBLIC WORKS CONSTRUCTION
STANDARD PLAN
323-2
MANHOLE - CONCRETE
BOX STRORM DRAIN
SHEET 2 OF 2
S.P.P.W.C. STD. 323-2 DETAIL
N.T.S.
RCB OR
RC ARCH*
..0
O
w rT
----
w ¢
o
O
w
B
/
dF-
F
FN Z
PLAN
FN * ARCH MAY HAVE A HORSESHOE -
SHAPED, CIRCULAR, ELLIPTICAL
°
CE ° 0
Uj M
OR SIMILAR CROSS SECTION.
wa
°
w
V)w
�1
I >r� r.-r �--r. -•--ram �--�-.
I
P, SEE NOTE 5
I
_ _ I
I
ELEVATION
STATION
L i ELEVATION
STATION
I tL �L
O 0 0� w :7i�=".�_.
° w "T
w a - ° N w
a -s t a F
FLr z
SECTION A -A Fn
SECTION B-B
FD
� ILLL FA I ItKIN Z FNUWIN IJ
-1CTORIAL ONLY, SEE NOTES
2 AND 7
OPTIONAL CONSTRUCTION
JOINT:
RCB OR ARCH TO RCP USE
CONST JOINT OF RCB OR ARCH.
RCB TO ARCH, USE CONST
JOINT OF RCB
STANDARD PLANS FOR PUBLIC WORKS CONSTRUCTION
PROMULGATED BY THE
PUBLIC WORKS STANDARDS INC.
TRANSITION STRUCTURE
STANDARD PLAN
GREENBOOK
1992 COMMITTEE
RCB TO PIPE
342- 2
REV. 1995. 2009
SHEET 1 OF 2
USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION
NOTES
1. THE HORIZONTAL ANGLE OF DIVERGENCE OR CONVERGENCE, G, SHALL
NOT EXCEED 5' 45'.
2. REINFORCING STEEL BAR SIZES, SPACING, PATTERN AND COVER OVER
THE STEEL SHALL BE AS FOLLOWS:
RCB TO RCP AND RCB TO ARCH - THAT OF RCB SECTION.
ARCH TO RCP - THAT OF ARCH SECTION.
ARCH TO ARCH - THAT OF ARCH SECTION HAVING THE THICKER
WALLS. THE BAR LENGTHS SHALL VARY UNIFORMLY THROUGHOUT
THE TRANSITION.
3. THE CONCRETE THICKNESS SHALL BE AS FOLLOWS:
RCB TO RCP AND ARCH TO RCP - THAT OF ARCH OR RCB
SECTION UNLESS THE WALL THICKNESS OF THE RCP PLUS 100 mm
(4") GREATER, IN WHICH CASE THE CONCRETE THICKNESS SHALL
VARY UNIFORMLY FROM THAT OF THE ARCH OR RCB SECTION
TO THAT OF THE RCP WALL PLUS 100 mm (4").
RCB TO ARCH AND ARCH TO ARCH - THAT OF THE ADJOINING RCB
OR ARCH SECTION AT EACH END OF THE TRANSITION AND SHALL
VARY UNIFORMLY BETWEEN THE TWO ENDS.
4. THE INTERIOR SURFACE SHALL BE SMOOTH AND VARY UNIFORMLY
BETWEEN THE TWO ADJOINING SECTIONS.
5. AT RCP JUNCTURE, EMBEDMENT P SHALL BE 130 mm (5") FOR PIPE
SIZE OF 2400 mm (96") OR LESS, AND 200 mm (8") FOR PIPE SIZES
OVER 2400 mm (96").
6. Vc= 28 MPa (4000 PSI) AT 28 DAYS AND THE CONCRETE SHALL BE THE
SAME MIX AS THE ADJACENT RCB.
7. ALL STEEL, EXCEPT LONGITUDINAL STEEL SHALL BE GRADE 400 (60)
BILLET STEEL CONFORMING TO ASTM A 615 M (A 615) AND SHALL
TERMINATE 40 mm (1 1/2") CLEAR OF CONCRETE SURFACE UNLESS
OTHERWISE SHOWN.
8. KEYED CONSTRUCTION JOINTS OF THE SAME DIMENSIONS AS THOSE
OF THE RCB OR ARCH SECTION MAY BE CARRIED THROUGH THE
TRANSITION STRUCTURE AT THE CONTRACTOR'S OPTION. SEE
SECTION B-B.
9. THE TRANSITION STRUCTURE SHALL BE CONSTRUCTED IN ACCORDANCE
THE STRUCTURAL NOTES APPLYING TO RCB OR ARCH
STRUCTURES SHOWN ON THE PLANS.
STANDARD PLANS FOR PUBLIC WORKS CONSTRUCTION
STANDARD PLAN
342-2
TRANSITION STRUCTURE
RCB TO PIPE
SHEET 2 OF 2
C MAIN
t LINE RCB
I T I
I IEl
C51E
N
U)
+VWV BARS 1
SEE NOTE 3
ROUND EDGE TO
3" (75 mm) R
STATION POINT,
SEE NOTE 2�
Z
/I
I 1
I
2-H BARS 4" OC
(100 mm), SEE NOTE-3-7
- CONSTRUCTION JOINT
T v #4 ®18" OC
/
#13M ® 450 mm) I
t LATERAL / F
CONNECTOR PIPE
�F
BARS T
B
T
n
'1/
4 ®18" OC
Q O#
®13M 450 mm)
0
OTH WAYS TO
-
BE USED WHEN F
��
B IS 60" (1500 mm)
OR MORE
BARS
� 3 0R #4 1 18
10M ®450 m) oc
SECTION G-G
ROUND EDGES TO
APPROXIMATE R
B
T
m
OF ID OF LATERAL
WITH A MAXIMUM
8
OF 3'-0" (1.0 m)
=
a
w
m
D & E BARS
o
D, E, H & G BARS
CONSTRUCTION JOINT
NEW OR EXISTING RCB, SEE NOTE 6
W BARS
D BARS
ANY STANDARD
F BARS PIPE JOINT
FI
ROUND
EDGES
#3 OR #4 ® 18" OC
i (10M 0 450 mm)
m P
EL S
SEE NOTE 8
E BARS
BARS 4"OC, SEE NOTE 3
(10
�T•
EL R, SEE NOTE 8
UNDISTURBED EARTH
asp'
BACKFILL WITH 450-C-2000
(265-C-14) MIX CONCRETE, OR
COMPACT SOIL TO RELATIVE DENSITY
REQUIRED BY SPECIFICATIONS. BACKFILL
MAY BE OMITTED IF STRUCTURE IS LAID
ON UNDISTURBED EARTH TO STORM
T,
DRAIN WALL.
STANDARD PLANS FOR PUBLIC WORKS CONSTRUCTION
PROMULGATED BY THE
STANDARD PLAN
PUBLICGREEBooKSCOMMITTEE'"°-
1984
JUNCTION STRUCTURE PIPE TO RCB
333-2
REV. 1996, 2009
SHEET 1 OF 2
USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION
For individual use only by fernando@thieneseng.com as per copyright law. Order ID: 0096147435
NOTES
1. VALUES FOR A, B AND C SHALL BE SHOWN ON THE PLANS.
ELEVATION R AND ELEVATION S SHALL BE SHOWN WHEN REQUIRED PER
NOTE 8.
2. STATIONS SPECIFIED ON THE PLANS APPLY AT THE INTERSECTION
OF CENTERLINES OF MAIN LINE AND LATERALS, EXCEPT THAT
STATIONS FOR CATCH BASIN CONNECTOR PIPES APPLY AT INSIDE WALL
OF STRUCTURE.
3. REINFORCING STEEL SHALL CONFORM TO ASTM A 615, GRADE 40, (ASTM
A 615M, GRADE 300), AND SHALL TERMINATE 1 1/2" (40 mm) CLEAR OF
CONCRETE SURFACE UNLESS OTHERWISE SHOWN.
a. W BARS ARE OF SIZE AND SPACING SPECIFIED FOR WALL STEEL ON
PLANS, AND SHALL BE CUT IN CENTER OF OPENING AND
BENT INTO TOP AND BOTTOM OF JUNCTION STRUCTURE.
b. OMIT H BARS WHEN SOFFIT OF SPUR IS 12" (300 mm) OR LESS BELOW
SOFFIT OF MAIN LINE, AND OMIT G BARS WHEN INVERT OF SPUR IS
12" (300 mm) OR LESS ABOVE FLOOR OF MAIN LINE.
4. JUNCTION STRUCTURE SHALL BE POURED MONOLITHICALLY WITH MAIN
LINE, MANHOLE OR TRANSITION STRUCTURE.
5. FLOOR OF STRUCTURE SHALL BE STEEL -TROWELED TO THE SPRING
LINE.
6. WHEN CONNECTING TO EXISTING RCB, BREAKOUT LIMITS AND DETAILS
SHALL BE SHOWN ON THE PLANS.
7. EMBEDMENT, P, SHALL BE 5" (130 mm) FOR B = 96" (2400 mm) OR LESS
8" (200 mm) FOR B OVER 96" (2400 mm).
8. IF ELEVATION R AND ELEVATION S ARE NOT SHOWN ON THE PLANS
THEN THE INLET OPENING SHALL FALL 6" (150 mm) BELOW
THE SOFFIT OF THE MAIN LINE WITH THE INLET PIPE LAID ON A STRAIGHT
GRADE FROM MAIN LINE TO CATCH BASIN OR TO GRADE BREAK IN INLET
LINE. ELEVATION S SHALL BE SHOWN ON THE PLANS IF THE INLET
OPENING FALLS MORE THAN 6" (150 mm) BELOW THE SOFFIT OF THE
MAIN LINE WITH THE INLET PIPE LAID ON A STRAIGHT GRADE
AS STATED ABOVE.
ELEVATION R SHALL BE SHOWN ON THE PLANS ONLY WHEN
A STUB IS TO BE PROVIDED FOR A FUTURE CONNECTION.
9. LATERALS OR CONNECTOR PIPES 24" (600 mm) OR LESS IN DIAMETER
SHALL BE NO MORE THAN 5' (1.5 m) ABOVE THE INVERT. LATERALS OR
CONNECTOR PIPES 27" (675 mm) OR LARGER IN DIAMETER SHALL BE NO
MORE THAN 18" (450 mm) ABOVE THE INVERT, WITH THE EXCEPTION THAT
CATCH BASIN CONNECTOR PIPES LESS THAN 50' (15 m) IN LENGTH SHALL
NOT BE MORE THAN 5' (1.5 m) ABOVE THE INVERT.
10. THE NEED FOR AN EDGE BEAM AND/OR ADDITIONAL REINFORCEMENT
SHALL BE INVESTIGATED BY THE ENGINEER FOR ANY ONE OF THE
FOLLOWING CONDITIONS:
a. ANGLE A IS LESS THAN 30'
b. TOP OF INLET PIPE IS LESS THAN 6" (150 mm) BELOW THE SOFFIT
c. FLOW LINE OF INLET PIPE IS LESS THAN 7" (180 mm) ABOVE THE
THE FLOOR OF THE RCB AT THE INSIDE FACE
STANDARD PLANS FOR PUBLIC WORKS CONSTRUCTION
STANDARD PLAN
JUNCTION STRUCTURE - PIPE TO RCB
SHEET 2 OF 2
SHEET
For individual use only by fernando@thieneseng.com as per copyright law. Order ID: 0096147435
S.P.P.W.C. STD. 333-2 DETAIL
N.T.S.
StormTekTM ST3/ST3G Installation: Connector Pipe Screen Filter
Plan View
a) StormTekTM ST3/ST3G
b) StormTekTM is installed in front of the
outflow pipe is supported by the frame
mounted on the existing catch basin wall
c) This device is designed to capture
trash, sediment and debris from entering
the storm water system.
Deflector Plate only
with ST3G Model
Basin Sump \
StormTekTI ST3/ST3G
Outflow Pipe
Structural Support Bars
(Bypass)
Y
Stainless Steel
1" flat bars
1/8" thickness
Stainless Steel Frame
(2" flat bars, 3/16" thick)
mounted to wall
Device fastens on pins
Heavy -Gage Sheet Metal Screen
S-304 Stainless Steel
5mm openings
Section A
General Notes:
- Bypass has
equivalent or greater
flow rate as outflow
pipe
- Device is retro-fitted
to catch basin
specifications
Deflector plate is the
only difference
between ST3 & ST313
1
10/25/2018
No.
Revision/Issue
iswlM &
s4
Maime,wca Services
P.O. Box 1627
Discovery Bay, CA 94505
StormTekTM Pipe Screen
Model ST3/ST3G
P.O. Box 1627
W1MSDiscovery
Bay, CA 94505
NorCal: 925.516.8966
stormTekTI
Storm Water Inspection &
�11�~� Maintenance Services
SoCal: 949.542.7234
No Scale
www.swimsclean.com
1 of 1
15
S.P.P.W.C. STD. 342-2 DETAIL 5 6 CONNECTOR PIPE SCREEN DETAIL 6 3
N.T.S. N.T.S.
MCN23-0099/ELPC22-000036
BASIS OF BEARINGS: BENCH MARK: p O SHOULD CONSTRUCTION OF THE REQUIRED QROFESS/pNq Prepared Under The Supervision Of : CITY OF FONTANA, CALIFORNIA
THE BASIS OF BEARINGS FOR THIS SURVEY CITY OF FONTANA BENCHMARK NO �585" �� D lF Th%eneS En %neer%n Inc.
IMPROVEMENTS NOT COMMENCE WITHIN TWO A�, TF PUBLIC STORM DRAIN IMPROVEMENT PLAN
IS THE CALIFORNIA STATE PLANE R S
COORDINATE SYSTEM (CCS83), ZONE 5, CIVIL ENGINEERING • LAND SURVEYING
NORTH AMERICAN DATUM 1983 (NAD83) FD. R. R. SPK. IN PPJJ20908 AT o YEARS OF THE DATE OF APPROVAL SHOWN HEREON Lv 2� 14349 FIRESTONE BOULEVARD DRAWN BY: SCALE:
BASED LOCALLY ON CONTINUOUSLY NORTHWEST CORNER OF SANTA ANA Of (n LA M/RADA, CALIFORN/A 90638 DETAILS
OPERATING REFERENCE STATIONS (cogs) AVENUE &ALMOND AVENUE. DIAL AND CARRIED FORTH IN A DILIGENT MANNER, THE * R.C.E. N0. 56155r * PH.(714)521-4811 FAX(714)521-4173 MH FOR AS SHOWN
••EWPP•' AND "GISA•' AS BEING NORTH "" T 40 W❑RKING DESIGNED BY:
PER STREET IMPROVEMENT PLAN 3487 Exp. 12-31-24 Q CALA.BA8H IN�UBTRIAL CEVELOPMENT DATE:
82.35.11" WEST (BASIS OF BEARINGS) (# ) BEFORE DAYS BEF❑RE CITY ENGINEER MAY REQUIRE REVISIONS TO THE �
25
(GRID) AND REPRESENTED HEREON BY THE Y❑U DIG Y❑u DIG PLANS TO BRING THEM INTO CONFORMANCE WITH 9�F C/v\� o`�= ""� Date 2/6/25 CHECKED�BY: APPROVED BY: PM 204�7 DRAWING CENTERLINE OF BANANA AVENUE AS BEING ELEYAT/ON = 965.46' /CIRCUIT 6 72 TOLL FREE 1-800-422-4133 OF �F
NORTH 00.20'03•' EAST. (2010.0 EPOCH) t/ A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT STANDARDS IN EFFECT. 0 A�" BW DAB 6792
REV. REVISION DESCRIPTION DATE ENGR. CITY DATE REINHARD STENZEL RCE N0. 56155 GIA LAM KIM CITY ENGINEER R.C.E. 62296rJ
Last Update: 02/06/2025
0:\3900-3999\3941\PUBLIC STORM DRAIN\3941SD05-DE(AIL.dwg