Loading...
HomeMy WebLinkAboutELPC19-000017 - APPROVED STREET IMPROVEMENT PLANGENERAL NOTES FOR STREET IMPROVEMENT PLANS 1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. .3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF=WAY WITHIN THE CITY LIMITS. CALL (909) 350- 7610. 5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 7. THE CONTRACTOR SHALL BE OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 8. THE WALLS AND FACES OF ALL EXCAVATIONS FOR GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 10. THE LOCATION OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE. IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOIR TO WORK AROUND THEIR FACILITIES. 12. THE CONTRACTOR SHALL NOT OPERATE, ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FRO VALVE OPERATION AND WATER REQUIREMENTS. 13. CURVE DATA REFERS TO THE FACE CURB. 14. STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT WHERE OTHERWISE NOTED. 15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTORS SHALL BE RESPONSIBLE FOR THE RESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS. SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 20. ALL GRADING OPERATIONS SHALL BE DISCONTINUED WHEN SUSTAINED WIND VELOCITIES EXCEED 25 MILES PER HOUR. 21. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 22. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 23. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 24. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 25. THE FINAL LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS SHALL BE APPROVED AT THE TIME OF CONSTRUCTION AND SHALL CONFORM TO THE CITY OF FONTANA STANDARD DETAILS. 26. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE. 27. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER. 28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. BENCHMARK: CITY OF FONTANA BENCHMARK NO. 28 ELEVATION = 1222.41 FT. BEING A MAG NAIL IN TOP OF CURB LOCATED AT THE ECR AT THE NE CORNER OF THE INTERSECTION OF MERRILL AVENUE AND OLEANDER AVENUE. BASIS OF BEARING BASIS OF BEARINGS IS THE CENTERLINE OF OLEANDER AVENUE WHICH BEARS NO-12-30W PER RSB 72/97. STREET IMPROVEMENT PLAN AT N/E CORNER OF FONTANA AVENUE AND LEMON STREET 29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOIR TO PLACEMENT. 31. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION AND APPROVAL OF THE CITY ENGINEER AS DETERMINED BY SOILS TAKEN AFTER COMPLETION OF ROUGH GRADING. 32. ACTUAL THICKNESS OF A.C. PAVEMENT AND/OR BASE COURSE MATERIAL FOR STRUCTURAL STREET SECTIONS SHALL BE RECOMMENDED BY A GEOTHECHNICAL REPORT AND SUBMITTED TO THE CITY OF FONTANA FOR APPROVAL UPON COMPLETION OF ROUGH GRADING. 33. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. 34. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 35. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALKS AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE CITY ENGINEER. 36. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. Cor ner stone Land ur veying Inc. A.L. T. A.• Topograph i c • Boundary -Construct ion • Env i ronwnta I 9-073D KNOB PLACE PERRIS, CA 9'?510 PH (1951) 26-0200 CL (1949) 2-M-7099 PRIVATE ENGINEER'S NOTICE TO CONTRACTORS: THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS. ALL CONTRACTORS AND SUBCONTRACTORS PERFORMING WORK SHOWN ON OR RELATED TO THESE PLANS SHALL CONDUCT THEIR OPERATIONS SO THAT ALL EMPLOYEES ARE PROVIDED A SAFE PLACE TO WORK AND THE PUBLIC IS PROTECTED. ALL CONTRACTORS AND SUBCONTRACTORS SHALL COMPLY WITH THE "OCCUPATIONAL SAFEIY AND HEALTH REGUTATIONS" OF THE U.S DEPARTMENT OF LABOR, AND WITH THE STATE OF CALIFORNIA DEPARTMENT OF INDUSTRIAL RELATIONS' "CONSTRUCTION SAFETY ORDERS". THE CIVIL ENGINEER SHALL NOT BE RESPONSIBLE IN ANY WAY FOR THE CONTRACTORS'AND SUBCONTRACTORS' COMPLIANCE WITH THE "OCCUPATIONAL SAFETY AND HEALTH REGULATIONS" OF THE U.S. DEPARTMENT OF LABOR OR WITH THE STATE OF CALIFORNIA DEPARTMENT OF INDUSTRIAL RELATIONS "'CONSTRUCTION SAFETY ORDERS". CONTRACTOR FURTHER AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR ANY LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR ENGINEER. NOTES: CITY ACCEPTANCE OF PLANS DOES NOT RELIEVE THE DEVELOPER FROM RESPONSIBILITY FOR THE CORRECTION OF ERRORS AND OMISSIONS DISCOVERED DURING CONSTRUCTION. UPON REQUEST OF THE CITY INSPECTOR, THE REQUIRED PLAN REVISIONS SHALL BE PROMPTLY SUBMITTED TO THE CITY ENGINEER FOR REVIEW. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING SAFELY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CON11NOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF DESIGN PROFESSIONAL TOLL FREE -qmmmmPp- 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REV. phPERTY LINE (TYP) APN 193-021-26 (N.A.P.) 12_. 7 11 � 6 I 5 � g 4 I. i� j - 3 vs .I APN 193-021-22 APN 193 021-09 r" Z (N.A.P.) (N.A.P:} PROPERTY LINE (TYP) { INDEX MAP 1 =100' W'LY E'LY R/W 102' R/W 14' 72' 16' 1 5.5' 8.5' 36' 36, 9.5' 6' 1 0.5' ARIES 20' TO 34' 13.5 TO PROP. 8" 1 " 10, 20.3' CURB & GUTTE EXIST. 6 21% CURB & GUTTER 2' VARIES 1.7% MIN ` `~--- 3.5� MAX 2% (WHERE OCCURS) ~-PROP. 6' SIDEWALK GRIND AND OVERLAY EXIST. EDGE OF 0.2' MIN. DEPTH SAWCUT PAVEMENT LINE T.I. = 10 FONTANA AVE NTS STA. 10+03.00 TO 15+78.00 UTILITY CONTACTS: ELECTRIC SEWER SOUTHERN CALIFORNIA EDISON CITY OF FONTANA 501 SOUTH MARENGO AVENUE 8353 SIERRA AVENUE BLDG "E" FONTANA, CA 92335 ALHAMBRA, CA 91802 909-350-6632 626-308-6313 ATTN: ORLANDO OLIVAS WATER FONTANA WATER COMPANY GAS 11142 GARVEY AVENUE THE GAS COMPANY EL MONTE, CA 91733 1918 WEST LUGONIA AVENUE 626-448-6183 REDLANDS, CA 92374 ATTN: LUIS MONTENEGRO 909-335-7715 ATTN: DENNIS WARE, PLANNER CABLE TELEVISION TELEPHONE TIME WARNER TELECOM AT&T 3281 EAST GUASTI ROAD 510-645-2929 SUITE 350 ATTN: SUSAN BLACKBURN ONTARIO, CA 91761 909-456-3652 UNAUTHORIZED CHANGES AND USES: CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANCES TO OR USES Of THESE PLANS. ASSESSOR'S PARCEL NUMBER: 0193-021-50, -51, -52, -53, -06, -07, & -08, PREPARED FOR/ OWNER /SUBDIVIDER: SECURED INCOME GROUP, INC. ATTN: MR. MAX MCDERMOTT 17592 17TH STREET, SUITE 100 TUSTIN, CA. 92780 (714) 721-7788 OFFICE (714) 368-0012 FAX PROPERTY ADDRESS: N/E CORNER OF FONTANA AVE AND LEMON ST. ZONING: SINGLE FAMILY RESIDENTIAL SHEET INDEX: SHEET 1: TITLE SHEET SHEET 2: STREET PLAN AND PROFILE SHEET 3: STREET SECTIONS LEGEND AND ABBREVIATION PARCEL MAP BOUNDARY LINE DENOTES CENTERLINE - - DENOTES EXISTING RIGHT OF WAY DENOTES EXISTING LOT LINE DENOTES FLOWLINE DENOTES EXISTING WATER 12"S - DENOTES EXISTING SEWER DENOTES EXISTING GAS -- - DENOTES EXISTING CHAIN LINK FENCE Room- -low- Am= DENOTES PROPOSED SITE WALL DENOTES EXISTING SEWER LINE DENOTES EXISTING WATER LINE - - -! - - - DENOTES EXISTING OVERHEAD POWERLINE EXISTING CONTOUR EXISTING IRR. STAND PIPE _ EXISTING POWER POLE r' EXISTING HOSEBIB Fi' EXISTING MAILBOX SIGN c FOUND MONUMENT EXISTING PALM 'J 3 EXISTING TREE EG EXISTING GRADE FG FINISH GRADE FL FLOWLINE FF FINISH FLOOR HP HIGHPOINT TC TOP OF CURB LINO UNLESS NOTED OTHERWISE SEWER MANHOLE FIRE HYDRANT EXISTING WATER VALVE � m EXISTING WATER METER EXISTING GAS METER OGV GAS VALVE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH REVISION DESCRIPTION ENGR. DATE CITY DATE STANDARDS IN EFFECT. No. * Exp. CIVIL 66 FOOTHILL BOULEVARD ARROW BOULEVARD z W z Uj MERRILL STREET PROJECT SITE P �Q� w z Q RANDALL AVENUE w o Wz � a < � Q W o- SAN BERNARDINO AVENUE �FF k w cn 0 Q Of ~ w J o U VALLEY BOULEVARD 10 SAN BERNARDINO FREEWAY VICINITY MAP NTS DENOTES RESTRICTED ACCESS SD DENOTES PROPOSED STORM DRAIN LINE S DENOTES PROPOSED SEWER LINE DENOTES PROPOSED WATER LINE CONSTRUCTION NOTES QTY. Oi CONSTRUCT 6.5" THICK ASPHALT CONCRETE MIN. OVER 12" MIN. OF 95% COMPACTED NATIVE SUBGRADE. 19,792 SF O2 CONSTRUCT 8" CURB AND GUTTER PER STD. 1000. 367 L.F. O3 CONSTRUCT 6' WIDE CONCRETE SIDEWALK PER STD. 1006. 1,897 SF O4 CONSTRUCT RESIDENTIAL DRIVEWAY PER STD. 1002 AND PER DETAIL HEREON. WIDTH W =SEE PLAN. 850 SF O5 SAWCUT 2', REMOVE AND REPLACE EX. AC PAVEMENT PAVEMENT THICKNESS TO MATCH EXISTING. 1,295 SF O INSTALL FIRE HYDRANT PER SEPARATE PLANS. 1 EA O7 CONSTRUCT RESIDENTIAL CURB DRAIN PER STD. 3002. 3 EA Og REMOVE AND DISPOSE EX. FENCE. 252 LF Og RELOCATE EX. POLE. SEE PLAN FOR RELOCATED POLE LOCATION. 2 EA �p SALVAGE ST. LIGHT FIXTURE. SEE PLAN FOR RELOCATED ST. LIGHT LOCATION. 2 EA 11 REMOVE AND DISPOSE EXISTING TREE. 2 EA 12 PROPOSED LED STREET LIGHT (90 W) SCE PART N0. 10205811, PER STD. PLAN N0. 404 (CASE 1). 1 EA 13 DEMOLISH, REMOVE AND DISPOSE EX. AC DIKE. 20 LF 14 JOIN EX. CURB AND GUTTER AND SIDEWALK. SEE CITY DRAWING NO.'S 4104 & 5477 FOR REFERENCE. SEE PLAN DETAIL T HEREON. 1 LS 15 INSTALL THERMOPLASTIC 12" WHITE LINE (LIMIT LINE) PER CALTRANS PLAN A24F. 1 LS 16 PAINT EDGE LINE PER CALTRANS A20B DETAIL 276. 572 LF 17 REMOVE AND DISPOSE EX. PAVEMENT. 942 SF 18 GRIND AND OVERLAY 0.2' MIN. DEPTH 6,267 SF 19 INSTALL TEMPERORAY SIGNAGE "END OF WALK" OR 6' SECTION BARRICADE PER STD. PLAN 4000. 1 EA ELPC 19-0000-17 CITY OF FONTANA, CALIFORNIA STREET IMPROVEMENT PLANS DRAWN BY: GATS&M TITLE SHEET AS SHOWN DESIGNED BY: GATS&M APN 0193-021-50,-51,-52,-53,-06, -07, & -08 DATE: /N/PFONTANA AVENUEAND/LEMON STREET 2/06/2020 Date : 2-11-20 CHECKED BY: SCL AFPROVED/BY: � 6 1 9 �} DRAWING NO.: '� STEF N C. LANTHIER RCE:59052 �fg-� i CITY N IN R.C. E. 51152 �90$ Prepared Under The Supervision Of : 40 20 0 40 s0 SCALE IN FEET I inch = 40 ft. BENCHMARK: CITY OF FONTANA BENCHMARK NO. 28 ELEVATION = 1222.41 FT. BEING A MAG NAIL IN TOP OF CURB LOCATED AT THE ECR AT THE NE CORNER OF THE INTERSECTION OF MERRILL AVENUE AND OLEANDER AVENUE. BASIS OF BEARING: BASIS OF BEARINGS IS THE CENTERLINE OF OLEANDER AVENUE WHICH BEARS ND-12-30W PER RSB 72/97. Ell _ �= 11+00 i 2_ 1 _ _ ._..�_._ _ - ..... ._ --- L.j-_1 ­­_ E__ _ .} -.r-- _ - _ _- t' ._ _._'._..__..V ......__mot., �. �_-.d-,_.._ _ _. .... }_"' _?_•. _-_ _. �:.._ - r o0 l � An _4= \�_ _ T.__.�• _. _.._ _�_-� /����-+�'S�- �,. :.; �....._» { �.. _. ELF � ��-{�.�- � `'1. 12+00 13+00 I U+"U-"" FONTANA AVE - FONTANA A =LEMON ST. ----- ----=- _- 7 7O �' ,,, _, o I t s 1 Co o --o o ( o , o z i `.,1, o o z o N -o i oo- 18. rn•O - .- ,-- - tf) rn o k - - -- - - - -- + `o1--- en FE ")' \r�(` ionr'�`,\ ti'.. ,/ r ;f 4��.t°,`X Xr;"..>: ..../�/'r` .0 ,.1,�?✓ `„ r`. i '1[`✓ k{ `:>��ixiX..,4 . a� EX. STOP LEGEND ---t----+----'- -_ter - -- SCALE: HORIZ 1 "=40' VT 1 "=4' M 14+00 F- +I J Lr) F-: V) EX. R/W I ----- -EX GURB. _ r 1 0 0 -- o o b o o o ,; W__ 15+00 Ln o o o o oPar) 0 0 LO 0 0 T280 7.82 8.51 9.35 10.15 1H�85 1-3.61 14.08 15.12 5' 11 ; 11 EP E� --P EP EP EP EP EP _. _, 5 _ _ _ :3 o - _ - 'PROPOSED...17- STREET Ln ,': EX. -BLOCK ..WAL 10 93 00 9 0 '''' rn EX: R/W o 16 -9 ; , 6 1 DEDICATION PER INST. 9 10 1 6 1 N 4 EX. R/W 19-01 1642 O.R. 1.60 _ .1„50 16 1.601.9 %' v 1 1.86� 20 2 __ G .60 EX. CURB & 3 2 � 2 OB_ = z 1. 2% 15.74 EP - - -5 3: $ 2 14.95 EP { - -- € r, y 15.10 EG 17.00 GUTTER, - - - - -- - - - . � , ----y- - (610 E P iV 1 G) EP EG SIDEWALK & - PAR, _ My w -CO--- oJ CURB RAMP7 cow off_, ,- o -_.CDC 3 ocn� s . oU� C)C-) o w w • ter-. o U_ . a o c.� -� �-- -� '-� w `L o . t- �- o ' ' �3 = EDGE --OF EX. PAVEMENT f=- F- w w o CD oO oO _ � � � z ,n . d; o w • cc o . oo rn �n � nn` ; �n - o cci a J + "') 16. 54 EP (PROTECT)-c.,Ln� + rn LOq +LOB +oocv r.ow � .-°°vw `o°Dooro`'+.wo ±�00'0 ±oo 00 N� +,7N r'�:� ,�w`,o� `� .-w 16.80 EG / + �. a .- oi c6 a; c� ,- r �� n APN 193-021-26 �14 7APN 193-021-53 Tto L> 193-021-51 °O a APN (N.A.P.) CN APN 193-021-22 00 + J + (N.A.P.) STREET & PUBLIC UTILITY EASEMENT PER INSTRUMENT NO. 2006- 598605 0. R. DRAINAGE EASEMENT PER INSTRUMENT NO. 2019- 0121641 Cornerstone and Sur veyin Inc. A.L.T.A.•Topographic• Boundary • Construction • Envirowntal 9-0730 I XOB PLACE PERRIS, CAA 92570 PH (1951) 26-0200 CL (949) 2 (0- (mw EXISTING 5' SIDEWALK EASEMENT INSTRUMENT NO. 2019-0121641 TOLL FREE 'qqlmmmpw- 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REV. SIN PROPOSED 26' WIDE EMERGENCY VEHICLE ACCESS, PRIVATE ACCESS & PUBLIC UTILITY EASEMENT INSTRUMENT #2019-0121641 RECORDED 04-18-2019 LINE LENGTH BEARING L1 367.23' S 400296" W O CONSTRUCT 6.5" THICK ASPHALT CONCRETE MIN. OVER 12" MIN. OF 95% COMPACTED NATIVE SUBGRADE. �J CONSTRUCT 8" CURB AND GUTTER PER STD. 1000. Q CONSTRUCT 6' WIDE CONCRETE SIDEWALK PER STD. 1006. O CONSTRUCT RESIDENTIAL DRIVEWAY PER STD. 1002 AND PER DETAIL HEREON. WIDTH W = SEE PLAN. O SAWCUT 2', REMOVE AND REPLACE EX. AC PAVEMENT PAVEMENT THICKNESS TO MATCH EXISTING. INSTALL FIRE HYDRANT PER SEPARATE PLANS. O7 CONSTRUCT RESIDENTIAL CURB DRAIN PER STD. 3002. 8 REMOVE AND DISPOSE EX. FENCE. 0 g RELOCATE EX. POLE. SEE PLAN FOR RELOCATED POLE LOCATION. 10 SALVAGE ST. LIGHT FIXTURE. SEE PLAN FOR RELOCATED ST. LIGHT LOCATION. 11 REMOVE AND DISPOSE EXISTING TREE. 12 PROPOSED LED STREET LIGHT (90 W) SCE PART NO. 10205811, PER ' STD. PLAN NO. 404 (CASE 1). 13 DEMOLISH, REMOVE AND DISPOSE EX. AC DIKE. 14 JOIN EX. CURB AND GUTTER AND SIDEWALK. SEE CITY DRAWING NO.'S 4104 & 5477 FOR REFERENCE. SEE PLAN DETAIL '1' HEREON. 15 INSTALL THERMOPLASTIC 12" WHITE LINE (LIMIT LINE) PER CALTRANS PLAN A24F. 16 PAINT EDGE LINE PER CALTRANS A20B DETAIL 27B. 17 REMOVE AND DISPOSE EX. PAVEMENT. 18 GRIND AND OVERLAY 0.2' MIN. DEPTH 19 INSTALL TEMPERORAY SIGNAGE "END OF WALK" OR 6' SECTION BARRICADE PER STD. PLAN 4000. SHOULD CONSTRUCTION OF THE REQUIRED Prepared Under The Supervision Of : CITY OF FONTANA. CALIFORNIA IMPROVEMENTS NOT COMMENCE WITHIN TWO ` `: \`'' STREET IMPROVEMENT PLAN YEARS OF THE DATE OF APPROVAL SHOWN HEREON DRAWN BY: GATS&M t FONTANA AVENUE AS SHOWN AND CARRIED FORTH IN A DILIGENT MANNER, THE No. DESIGNED BY: GATSddA APN 0193-021-50, 51,-52,-53,=06, -07, & -OS DATE: CITY ENGINEER MAY REQUIRE REVISIONS TO THE * Exp. * -� / /N/E FONTANA AVENUE AND LEMON STREET 2/06/2020 PLANS TO BRING THEM INTO CONFORMANCE WITH : C'vi� Dote -/�-2� CHECKED BY: SCL c gPPR ED BY: ;/ �` DRAWING NO.: 2 d REVISION DESCRIPTION ENGR. DATE CITY DATE STANDARDS IN EFFECT. STEFAN C. LANTHIER RCE: 59052 5908 3 1 10.00 1 5.00 1 13.00 -20+00 -10+00 0+00 10+00 20+00 30+00 40+00 50+00 10+50.00 VERTICAL SCALE: 1 "=2' HORIZONTAL SCALE: 1"=10' o r 1 13.00 • ii 1 13.00 15.00 10.00 -30+00 -20+00 -10+00 0+00 10+00 20+00 30+00 40+00 50+00 1 1 +00.00 VERTICAL SCALE: 1 "=2' HORIZONTAL SCALE: 1 "=10' 1 -20+00 -1U+UU 0+00 1U+00 ZU+UU 30+0U 4U+UU SU+UU 1 1 +50.00 VERTICAL SCALE: 1 "=2' HORIZONTAL SCALE: 1 "=10' 2.0' oe o r_RIND_ &_ AY N: -DEPTH Z - Q I unu - e e p T►�nv -20+00 -1 U+UU 0+00 10+00 20+00 30+00 4U+UU SU+UU 12+00.00 VERTICAL SCALE: 1"=2' HORIZONTAL SCALE: 1 "=10' 2.0' -30+00 -20+00 -10+UU 0+00 10+00 20+00 3U+U0 40+UU SU+UU 12+50.00 VERTICAL SCALE: 1 "=2' HORIZONTAL SCALE: 1 "=10' BENCHMARK: CITY OF FONTANA BENCHMARK NO. 28 ELEVATION = 1222.41 FT. BEING A MAG NAIL IN TOP OF CURB LOCATED AT THE ECR AT THE NE CORNER OF THE INTERSECTION OF MERRILL AVENUE AND OLEANDER AVENUE. BASIS OF BEARING: BASIS OF BEARINGS IS THE CENTERLINE OF OLEANDER AVENUE WHICH BEARS NO-12-30W PER RSB 72/97. Q O Cor ner stone Lanur veyln nc. DIAL cl=13 a e 1, A.L.T.A.•Topographic • Boundary • Construction • Environmental BEFORE DAYS BEFORE Two WORKING 9-0730 IL\01; PLACE YOU DIG YOU DIG PERRIS, CA 99-5 � 0 PH (.951) 7,36-0200 CL (.949) :3 (0- 7099 TOLL FREE 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REV. 15.00 10.0 15.00 17.00 2.0' 111liAM111111 14.00 -30+00 -20+00 -1 U+UU U+UU 1 U+UU ZU+UU su+Vu 4U+UU SU+UU 13+00.00 VERTICAL SCALE: 1 "=2' HORIZONTAL SCALE: 1"=10' n n' 2.0' is n' -30+00 -20+00 -10+00 0+00 10+00 20+00 30+00 40+00 50+00 13+50.00 VERTICAL SCALE: 1 "=2' HORIZONTAL SCALE: 1 "=10' 2.0' 35. E�c.-BLocK-wL -PBOTE-CT--IN- �, -- -- �_I_I .............. _ 1 rD1►111 L I1l ` `•• KMIN. LO --"- �._ DEPTH C.- 6.5* 12.0011 17.00 12.00 19.00 14.00 -30+00 -20+00 -10+00 0+00 10+00 20+00 30+00 40+00 50+00 14+00.00 VERTICAL SCALE: 1 "= 2' HORIZONTAL SCALE: 1 "=10' 2.0' 1 1 -30+00 -20+00 -10+00 0+00 10+00 Z0+00 30+00 4U+UU SU+UU 14+ 50.00 VERTICAL SCALE: 1"=2' HORIZONTAL SCALE: 1 "=10' 2.0' : ExBLOCK-WALL -- __ _ __ _--- -- _-- -- _. cfl a. ►- I (PROTECT-IN-PL-ACE)- �- 0:2'--MIN: DE-P 6 r�•-�-- _- AC -PAVEMENT c� -30+00 -20+00 -1 U+UU U+UU 1 U+UU ZU+UU 3U+UU 4U+UU OU+UU 15+50.00 VERTICAL SCALE: 1 "=2' HORIZONTAL SCALE: 1"=10' -30+00 -20+00 -10+00 0+00 10+00 20+00 30+00 40+00 50+00 15+00, 00 VERTICAL SCALE: 1 "=2' HORIZONTAL SCALE: 1 "=10' SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON f`-�,c• ��``~' AND CARRIED FORTH IN A DILIGENT MANNER, THE No. CITY ENGINEER MAY REQUIRE REVISIONS TO THE # Exp. PLANS TO BRING THEM INTO CONFORMANCE WITH civic REVISION DESCRIPTION ENGR. DATE CITY DATE STANDARDS IN EFFECT. I Prepared Under The Supervision Ot : CITY OF FONTANA, CALIFORNIA STREET SECTIONS DRAWN BY: GATS&M FONTANA AVENUE AS SHOWN DESIGNED BY: GATS&M APN 0193-021-50,-51,-52,-53,-06, -07, & -08 DATE: `N/EEO ANA AVENUE ,% NON STREET 2/06/2020 Date : 2-11-29 CHECKED BY: SCL APPR .VED BY� DRAWING NO.: 3 STEFAN C. LANTHIER RCE:59052 I ENGIN11 5908 3