Loading...
HomeMy WebLinkAboutAPPROVED - ELPC22-000075 - STREET PLANS DWG . NO. 6327JUNE 21, 2023 GRIND AND OVERLAY DETAIL MH MH MH MH MH EX AC PAVE TYPICAL SECTION SLOVER AVE > MEDIAN PROPOSED 52.0' 42.0' EXIST 8" C&G 2% VARIES R/W S'LY R/W N'LY 10.0' S/W 6.0' 2.0% CONSTRUCTION NOTES: 6 QUANTITY ESTIMATED 1 2 3 4 5 SAWCUT AND REMOVE EXIST AC PAVEMENT (1.0' MIN) SLOVER AVE CONSTRUCT 8" CURB PER CITY STD 1000 REMOVE EXIST MEDIAN 236 LF 6 SF 437 SF (19.7 TON) 848 SF NATIVE SUBGRADE CONSTRUCT 7.5" AC PAVEMENT OVER 12" MIN OF 95% COMPACTED SCALE 1"=10' T.I.=10.0 SHEET 2 236-101-23 APN 236-011-17 APN SHEET INDEX: SHT. 3 - CHERRY AVE STREET IMPROVEMENT PLAN SHT. 2 - SLOVER AVE STREET IMPROVEMENT PLAN SHT. 1 - TITLE SHEET FOR LOCATION AND SPECIFICATIONS PROPOSED STREET LIGHT, SEE STREET LIGHT PLAN DWG NO. 6327LT 2 EA BASIS OF BEARING: OF SAN BERNARDINO COUNTY. 149 OF RECORD OF SURVEYS, PAGE 49, RECORDS PER RECORD OF SURVEY 12-055, FILED IN BO0K CENTERLINE OF CHERRY AVE AS N 00°39'54"E C H E R R Y A V E SITE VICINITY MAP NOT TO SCALE 10 C H ER R Y AVE SLOVER AVE SANTA ANA AVE LIVE OAK AVE ALMO N D AVE 050 50 100 150 SCALE 1"= 50' 52.0' 2.0% VARIES (3.1' - 9.1') 4.0'1.0'1.0' 31 1 2 2 PRIVATE ENGINEER'S NOTE LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. CONNECTION WITH THE PERFORMANCE OR WORK ON THIS PROJECT, EXCEPTING FOR THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE CITY, THE OWNER AND APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL FOR JOBSITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY DRAWINGS. FOR UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE EXCEPT AS SHOWN ON THESE DRAWINGS. THE CONTRACTOR IS REQUIRED TO TAKE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES, CONDUITS OR UTILITY PROVIDERS: GAS - SO CA GAS CO (800) 427-2200 ELECTRIC - S.C.E. (800) 655-4555 SEWER - CITY OF FONTANA 909-350-7675 WATER - FONTANA WATER 909-822-2201 SLOVER AVE SAWCUT LINE SAWCUT LINE 2% 11'11' GRIND AND OVERLAY AC PAVEMENT, 0.10' MIN PER DETAIL 4,875 SF (35.1 TON)5 (2% +/-)(2% +/-)PAVE EX AC EXIST 8" C&G 5 1' PAVE EX AC OVERLAY 0.10' MIN PAVEMENT AND GRIND 0.10' MIN EXIST PAVE NEW AC CURB MEDIAN NEW 8" TC = EX FS + 8" MIN 7 CONSTRUCT COMMERCIAL DRIVEWAY PER CITY STD 1001 2,600 SF 8 REMOVE EXIST CURB & GUTTER 200 LF 9 REMOVE EXIST SIDEWALK 1,100 SF S H E E T 3 5 AS SHOWN STREET IMPROVEMENT PLANS CITY OF FONTANA 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. STREET IMPROVEMENT GENERAL NOTES RECORD DRAWINGS TO THE CITY ENGINEER. AS-BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE CONSTRUCTION TO THE SATISFACTION OF THE CITY ENGINEER. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALKS AFFECTED BY THE OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND CONTRACTOR UPON COMPLETION OF PAVING. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING COMPLETION OF ROUGH GRADING. RECOMMENDED BY A GEOTECHNICAL REPORT AND SUBMITTED TO THE CITY OF FONTANA FOR APPROVAL UPON ACTUAL THICKNESS OF A.C. PAVEMENT AND/OR BASE COURSE MATERIAL FOR STRUCTURAL STREET SECTIONS SHALL BE ENGINEER AS DETERMINED BY SOILS TESTS TAKEN AFTER COMPLETION OF ROUGH GRADING. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION AND APPROVAL OF THE CITY APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. APPROVED. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER LATERAL. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE. CONSTRUCTION AND SHALL CONFORM TO THE CITY OF FONTANA STANDARD DETAILS. THE FINAL LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS SHALL BE APPROVED AT THE TIME OF LEAVING IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. DENSITY SHALL REQUIRE RE-WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. APPROVAL. PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO ALL GRADING OPERATIONS SHALL BE DISCONTINUED WHEN SUSTAINED WIND VELOCITIES EXCEED 25 MILES PER HOUR. WATERING, AT ALL TIMES. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE VEHICLES. FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOR LATER REPLACEMENT OF THE MONUMENT. SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY REMOVAL AND REPLACEMENT OF EXISTING SURVEYCONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND PRIOR NOTIFICATION TO THE CITY ENGINEER. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT WHERE OTHERWISE NOTED. CURVE DATA REFERS TO THE FACE OF CURB. AND WATER REQUIREMENTS. AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL PERMIT FOR THAT PURPOSE. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE GUARDED WHEN THE OTENTIAL EXISTS FOR GROUND MOVEMENT. OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR CONTROL DEVICES AT ALL TIMES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC BY THE CITY TRAFFIC ENGINEER. STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON-METRIC EDITION UNLESS OTHERWISE DIRECTED THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE CALL (909) 350-7610. LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT F.H. = FIRE HYDRANT STLT = STREET LIGHT TRFSIG = TRAFFIC SIGNAL = SIGN PB = PULL BOX WV = WATER VALVE SMH = SEWER MANHOLE SDMH = STORM DRAIN MANHOLE TELMH = TELEPHONE MANHOLE PP = POWER POLE WM = WATER METER TELPED = TELEPHONE PEDESTAL ELEC VAULT = ELECTRIC VAULT MB = MAIL BOX TC = TOP OF CURB FL = FLOW LINE TB = TOP OF BERM FS = FINISH SURFACE FG = FINISH GRAGE BW = BACK OF WALK PROP AC PAVEMENTS/W = SIDEWALK SLOVER AVE & CHERRY AVE AT APN 0236-101-23 SAWCUT & REMOVE AC PAVE PM 20653 PROP AC PAVEMENT GRIND AND OVERLAY REV.REVISION DESCRIPTION ENGR.DATE CITY DATE CHECKED BY: DESIGNED BY: AND CARRIED FORTH IN A DILIGENT MANNER, THE STANDARDS IN EFFECT. PLANS TO BRING THEM INTO CONFORMANCE WITH CITY ENGINEER MAY REQUIRE REVISIONS TO THE IMPROVEMENTS NOT COMMENCE WITHIN TWO SHOULD CONSTRUCTION OF THE REQUIRED YEARS OF THE DATE OF APPROVAL SHOWN HEREON DRAWN BY: 3 CITY OF FONTANA, CALIFORNIA APPROVED BY:DRAWING NO.: 6327 DATE: SCALE: STREET IMPROVEMENT PLAN SLOVER AVE & CHERRY AVE DATE: AS SHOWN JUNE 2023 SFH SFH DLG BENCHMARK: ELEV. 981.36 AND SANTA ANA AVE. NORTHWEST CORNER OF REDWOOD AVE PK NAIL IN POLE NO. 335739E AT THE CITY OF FONTANA BM NO. 517 AT PM 20653 GIA LAM KIM / CITY ENGINEER R.C.E. 62296 TITLE SHEET 1 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT BEFORE YOU DIG TOLL FREE DIAL DAYS BEFORE 1-800-227-2600 TWO WORKING YOU DIG R EG STE ERDSSO A L E N G E N E E R CAL FORNIAST T A E OF NFPRO CIVIL No. 28500 Expir es 3-31- D O UGLAS N G O O DMA L. 24 Goodman& ASSOCIATES COLTON, CA 92324 2079 SKY VIEW DRIVE (909) 824-2775 DATEDOUGLAS L. GOODMAN RCE 28500, 3-31-2024 7/18/2023 JUNE 21, 2023 10+00.00 CL CHERRY AVE 64+03.90 CL SLOVER AVE = 6463625857 EX C&G PER DWG NO. 5109 EX 8" RAISED MEDIAN 5 2 ' 5 9 + 7 7 . 4 3 6 1 + 8 5 . 4 0 4 . 0 ' L=5.50' R=1.75' SAWCUT SAWCUT N 86°48'24" E 115.21' N 86°48'24" E 115.21' N 89°45'54" E N.A.P. 3.1' EASEMENT PER PM 20653 PROPOSED SIDEWALK 5' (1003.54 FS) (1004.21 TC) ( 1 0 0 3 . 5 4 F S ) ( 1 0 0 4 . 2 1 T C ) 1002.77 FS 1003.44 TC 1002.75 FS 1003.42 TC PL W = 4 0 . 0 ' S T A 5 9 + 1 7 . 3 3 C L D W Y 40' 4'EX S/WEX S/W 2' 4 2 ' 6 ' 6 ' 5 9 + 5 4 . 7 1 5 9 + 6 2 . 3 0 5 8 + 7 4 . 2 4 5 8 + 8 0 . 1 1 MH MH 1005 1 0 0 5 1 0 0 5 1005 SLOVER AVE 236-011-23 APN 236-011-17 APN C H E R R Y A V E 30 300 60 90 SCALE 1"= 30' 616059 REV.REVISION DESCRIPTION ENGR.DATE CITY DATE CHECKED BY: DESIGNED BY: AND CARRIED FORTH IN A DILIGENT MANNER, THE STANDARDS IN EFFECT. PLANS TO BRING THEM INTO CONFORMANCE WITH CITY ENGINEER MAY REQUIRE REVISIONS TO THE IMPROVEMENTS NOT COMMENCE WITHIN TWO SHOULD CONSTRUCTION OF THE REQUIRED YEARS OF THE DATE OF APPROVAL SHOWN HEREON DRAWN BY: 3 CITY OF FONTANA, CALIFORNIA APPROVED BY:DRAWING NO.: 6327 DATE: SCALE: STREET IMPROVEMENT PLAN SLOVER AVE & CHERRY AVE DATE: AS SHOWN JUNE 2023 SFH SFH DLG BENCHMARK: ELEV. 981.36 AND SANTA ANA AVE. NORTHWEST CORNER OF REDWOOD AVE PK NAIL IN POLE NO. 335739E AT THE CITY OF FONTANA BM NO. 517 AT PM 20653 GIA LAM KIM / CITY ENGINEER R.C.E. 62296 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT BEFORE YOU DIG TOLL FREE DIAL DAYS BEFORE 1-800-227-2600 TWO WORKING YOU DIG 5 9 + 8 0 . 0 0 5 8 + 6 4 . 7 3 B C J O I N E X I S T M E D I A N 9.1' R EG STE ERDSSO A L E N G E N E E R CAL FORNIAST T A E OF NFPRO CIVIL No. 28500 Expir es 3-31- D O UGLAS N G O O DMA L. 24 Goodman& ASSOCIATES COLTON, CA 92324 2079 SKY VIEW DRIVE (909) 824-2775 DATEDOUGLAS L. GOODMAN RCE 28500, 3-31-2024 MEDIAN TREATMENT SEE LS PLANS FOR 4 . 0 ' 11' 11' EX R/W ( 2 . 0 % ) ( 2 . 0 % ) 0.67% 0.67% JOIN EX CURB & S/W BEG REMOVALS (1002.89 TC) 58+63.88 BC JOIN EX CURB & S/W END REMOVALS (1003.23 TC) 59+72.45 EC R=35'R=35' 0" CURB 03.30 TC 0" CURB 03.10 TC 0.31% 2% 9. 6 % 1 5 ' EX R/W 0 3 . 1 8 T C / 0 " C U R B 0 3 . 3 6 T C / 0 " C U R B (0.4%) CONSTRUCTION NOTES: 6 1 2 3 4 5 SAWCUT AND REMOVE EXIST AC PAVEMENT (1.0' MIN) CONSTRUCT 8" CURB PER CITY STD 1000 REMOVE EXIST MEDIAN NATIVE SUBGRADE CONSTRUCT 7.5" AC PAVEMENT OVER 12" MIN OF 95% COMPACTED FOR LOCATION AND SPECIFICATIONS PROPOSED STREET LIGHT, SEE STREET LIGHT PLAN DWG NO. 6327LT GRIND AND OVERLAY AC PAVEMENT, 0.10' MIN PER DETAIL 7 CONSTRUCT COMMERCIAL DRIVEWAY PER CITY STD 1001 8 REMOVE EXIST CURB & GUTTER 9 REMOVE EXIST SIDEWALK 7 8 9 3 1 89 6 6 2 2 3 1 1 2 5 5 5 4 2 SLOVER AVE IMPROVEMENT PLAN 7/18/2023 JUNE 21, 2023 E X C & G PL EX RAISED MEDIAN LIGHT EX ST LIGHT EX ST 4 0 ' 66' 56' E X S / W E X S / W EASEMENT PER PM 20653 PROPOSED SIDEWALK 6' 6' MH MH MH 9 9 5 9 9 5 9 9 5 9 9 5 1 0 0 0 1000 236-011-23 APN C H E R R Y A V E 30 300 60 90 SCALE 1"= 30' 6 1 6 0 5 9 REV.REVISION DESCRIPTION ENGR.DATE CITY DATE CHECKED BY: DESIGNED BY: AND CARRIED FORTH IN A DILIGENT MANNER, THE STANDARDS IN EFFECT. PLANS TO BRING THEM INTO CONFORMANCE WITH CITY ENGINEER MAY REQUIRE REVISIONS TO THE IMPROVEMENTS NOT COMMENCE WITHIN TWO SHOULD CONSTRUCTION OF THE REQUIRED YEARS OF THE DATE OF APPROVAL SHOWN HEREON DRAWN BY: 3 CITY OF FONTANA, CALIFORNIA APPROVED BY:DRAWING NO.: 6327 DATE: SCALE: STREET IMPROVEMENT PLAN SLOVER AVE & CHERRY AVE DATE: AS SHOWN JUNE 2023 SFH SFH DLG BENCHMARK: ELEV. 981.36 AND SANTA ANA AVE. NORTHWEST CORNER OF REDWOOD AVE PK NAIL IN POLE NO. 335739E AT THE CITY OF FONTANA BM NO. 517 AT PM 20653 GIA LAM KIM / CITY ENGINEER R.C.E. 62296 3 CHERRY AVE IMPROVEMENT PLAN A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT BEFORE YOU DIG TOLL FREE DIAL DAYS BEFORE 1-800-227-2600 TWO WORKING YOU DIG R EG STE ERDSSO A L E N G E N E E R CAL FORNIAST T A E OF NFPRO CIVIL No. 28500 Expir es 3-31- D O UGLAS N G O O DMA L. 24 Goodman& ASSOCIATES COLTON, CA 92324 2079 SKY VIEW DRIVE (909) 824-2775 DATEDOUGLAS L. GOODMAN RCE 28500, 3-31-2024 5 8 5 7 E X R / W N 0 ° 3 9 ' 5 4 " E W=40.0' STA 57+56.72 CL DWY JOIN EX CURB & S/W BEG REMOVALS (995.14 TC) 57+15.31 EC JOIN EX CURB & S/W END REMOVALS (996.51 TC) 58+07.57 BC R=35' R=19' 995.62 TC/0" CURB 996.32 TC/0" CURB 4' 2' 2% 9.8% 1 . 4 8 % 16' E X R / W STA 57+96.93 STA 57+21.24 995.53 TC/0" CURB 996.37 TC/0" CURB CONSTRUCTION NOTES: 6 1 2 3 4 5 SAWCUT AND REMOVE EXIST AC PAVEMENT (1.0' MIN) CONSTRUCT 8" CURB PER CITY STD 1000 REMOVE EXIST MEDIAN NATIVE SUBGRADE CONSTRUCT 7.5" AC PAVEMENT OVER 12" MIN OF 95% COMPACTED FOR LOCATION AND SPECIFICATIONS PROPOSED STREET LIGHT, SEE STREET LIGHT PLAN DWG NO. 6327LT GRIND AND OVERLAY AC PAVEMENT, 0.10' MIN PER DETAIL 7 CONSTRUCT COMMERCIAL DRIVEWAY PER CITY STD 1001 8 REMOVE EXIST CURB & GUTTER 9 REMOVE EXIST SIDEWALK 7 8 9 1 39 8 5 7/18/2023