Loading...
HomeMy WebLinkAbout5657-1I EXIST. R/W I~ 1~ ~---------1-~----~~~ ! OJ< /EXIST. C&G SIGNING AND STRIPING GENERAL NOTES 1. CONSTRUCTiON PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA DEPARTMENT OF ENGINEERING PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF--WAY WITH IN THE CITY LIMITS. CALL (909) 350-7610. 2. ALL WORK, MATERIALS, EQUIPMENT AND TEMPORARY TRAFFIC CONTROL SHALL CONFORM TO THESE PLANS, THE CITY OF FONTANA STANDARD SPECIFICATIONS, THE CITY'S SPECIAL PROVISIONS, SECTION E, THE STANDARD PLANS AND SPECIFICATIONS OF THE STATE OF CALIFORNIA, DATED 2010, AND THE CALIFORNIA MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES, DATED 2014. 3. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN TEMPORARY TRAFFIC CONTROL AT ALL TIMES. 4. ALL SIGNS SHALL BE INSTALLED PER CITY STANDARD DETAIL 4003, UNLESS OTHERWISE SHOWN ON THE PLANS. 5. ALL STRIPING AND PAVEMENT MARKINGS SHALL BE ALKYD THERMOPLASTIC UNLESS OTHERWISE NOTED. 6. SUBSTITUTE TYPE "C" RAISED PAVEMENT MARKERS FOR TYPE "G" MARKERS ON DETAIL 38 ON ROADWAYS WITH RAISED MEDIANS. 7. SUBSTITUTE DETAIL 14A STRIPING FOR DETAIL 12 STRIPING FOR ROADWAYS WITH RAISED MEDIANS. 8. STRIPING AND PAVEMENT MARKINGS TO BE REMOVED SHALL BE REMOVED BY SANDBLASTING OR OTHER APPROVED METHODS, NONE OF WHICH SHALL DAMAGE THE PAVEMENT. THE 'BLACK OUT' METHOD OF REMOVAL IS NOT PERMITIED. ANY PAVEMENT DAMAGED BY REMOVALS SHALL BE REPAIRED PER APPROVAL OF THE CITY ENGINEER AT NO COST TO THE CITY. 9. CONTROL POINTS OR "CAT TRACKING" SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO APPLICATION OF PAVEMENT STRIPING AND LEGENDS. NOTIFY THE CITY AT LEAST TWO DAYS PRIOR FOR APPROVAL OF "CAT TRACKING." 10. STRIPING AND PAVEMENT MARKINGS SHALL BE APPLIED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS. 11. BLUE RAISED PAVEMENT MARKERS SHALL BE INSTALLED AT ALL FIRE HYDRANT LOCATIONS PER CITY STANDARD PLANS. 12. AS-BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS AND ELECTRONIC AUTOCAD FILES TO THE CITY ENGINEER. ---f3- ~ EXIST. R/W J]' £ffi©~lli JM£J]' ll®~$~ lliiTWm:J ©£~ m3WJ~IT~m:J~~ ©m:J~rijfm:Jffi ©illft?W ©w w©~lft? £~ £ LIVE OAK AVENUE (26') 1 (14') r 01 CL INT. 1 0+18.35 JURUPA AVE = 9 +57.80 LIVE OAK AVE I ( +--·f--....-==:.::==- -~ ~~~S' ~ ~ "N -~ ,-;:;-,..; - C' . ., _!,' ::::. '~-1J /EXIST. C&G 2 ---c:-. I T --- n ' -I ·--~I r;; I -I n I _____ fO ~~ ---I N N ---'---'----- "'-EXIST. C&G ... /EXIST. C&G q ....... · ..... . r- -~~-'-'1 ~"-c5 ~~~-·-./{1] -. -~ -b---t JURUPA AVENUE LEGEND ::::;;t~======!\®F-===== ~~~Li ,:>£ SLOVER A VENUE w ::> ~ ROSE CT < )-"' "' "' 5 SANTA AN A A VENUE JURUPA AVENUE VICINITY MAP NOT TO SCALE I r~: , i) L-------------------------------------------~ CONSTRUCTION NOTES [iJ PROTECT EXISTING STRIPING AND/OR MARKINGS .. II] APPLY THERMOPLASTIC 4" SOLID DOUBLE YELLOW LINE PER CALTRANS STD. PLAN A20A, DETAIL 22 . 0 II] lil 0 [2] 0 0 IT9J [ill @] @] ~ @] ~ @] APPLY PAINT "STOP" STENCil. PER CAL TRANS STD. PLAN A24D APPLY THERMOPLASTIC 12" SOLID WHITE CROSSWALK LINE PER CAL TRANS STD. PLAN A24F APPLY THERMOPLASTIC 8" WHITE CHANNELIZING LINE PER CALTRANS STD. PLAN A20D, DETAIL 38 APPLY THERMOPLASTIC TYPE IV (L) TURN ARROW PER CAL TRANS STD. PLAN A24A APPLY THERMOPLASTIC 4" SOLID WHITE RIGHT EDGE LINE PER CAL TRANS STD. PLAN A20B, DETAIL 278 SUPPLY AND iNSTALL TRAFFIC SIGN AND POST PER CITY OF FONTANA STD. 4003 SUPPLY AND INSTALL TRAFFIC SIGN ON STREET LIGHT PER CITY STD. 4003 APPLY PAINT "STOP AHEAD" STENCIL PER CALTRANS STD. PLAN A24D INSTALL BLUE DOT REFLECTIVE PAVEMENT MARKER PER CITY OF FONTANA STD. NO. 6001 . APPLY THERMOPLASTIC TYPE VI ARROW PER CAL TRANS STD. PLAN A24A APPLY THERMOPLASTIC 4" WHITE DASHED LINE PER CAL TRANS STD. PLAN A20A, DETAIL 12. APPLY THERMOPLASTIC 4" WHITE DASHED LII~E PER CALTR.ANS STD. PLAN A20B, DETAIL 29 APPLY THERMOPLASllC 4" SOLID WHITE LINE 60' LONG. REMOVE EXISTING TRAFFIC SIGN, SALVAGE TO CITY REMOVE EXISTING CONFLICTING STRIPING AND MARKING BY WET SANDBLASTING OR ALTERNATIVE METHOD APPROVED BY CiTY ENGINEER NOTE: REPLACE STRIPING IN-KIND THAT IS REMOVED WITH THE CONSTRUCTION OF THE SEWER OR STORM DRAIN LINES ~ f'-1 +I~ col l NOTE: REMOVE EXISTING CONFLICTING STRIPING WITHIN INTERSECTION R1-1 NOTE: STOP SIGNS SHALL REMAIN POSTED THROUGHOUT CONSTRUCTION SIGN LEGEND QUANTITIES 750 LF 3 EA 630 LF 220 LF 2 EA 632 LF 6 EA 3 EA 2 EA 3 EA 3 EA 794 LF 36 LF 120 LF 2 EA 1 LS _"(_ 9 W4-2 ~~ \ __ - ----· ------· " RIG~\ LANE v ~,~Noyf/ ~~~ W9-1 GRAPHIC SCALE 40 80 I j (IN FEET) 1"=40' W3-1 120 I 0 ~ ,n 3- §, ·:n ill 0 "' 3- 0 ·c ~ w ~ " c 0 a. 2 ~------------------------------r------------------------------,----~-------------------------------r----;----r----r----r--------------------------------r---------------~r-------------------------------------------------~r--------------------------------- BENCH MARK: THE BENCHMARK FOR THIS PROJECT IS BASED ON THE NA 1lONAL GEODETIC SURVEY (NGS) VERTICAL CONTROL NETWORK. BENCHMARK NUMBER PID EV9267 DESIGNATION UF-628, ELEVATION 1006.35' (NAVD88). BASIS OF BEARING: SEE TITLE SHEET I DIAL BEFORE YOU DIG TWO WORKING DAYS BEFORE YOU DIG TOLL FREE 1-800-227·-2600 NO. REVISION DESCRIPTION I DATE ENGR. DATE CITY Huitt-Zollars, Inc. CITY OF FONTANA, CALIFORNIA 0 1-------------------------------------------------------------------------------~~ 0 ~O@lNJOlNJ@ ~lNJ[Q) ~ulR\OrPDlNJ@ rPI.L~lNJ ~ ~~~~----,-----------------------------------------------------~~~------~~ DRAWN BY: PARCEL MAP 19834 SCALE: HZ STAFF AS SHOWN o DESIGNED BY: JURUPA A VENUE 1-::D:-::AT'::;:E:::..;: ='-----!~ ~~~M~.G~-~~~~~~-~~~~---------------------------------------+~1~1~/2~0~1_7.---~g Ontario 3990 CONCOURS, SUITE 330 ' ONTARIO, CALIFORNIA 91764 ' (909) 941-7799 PREPARED UNDER THE SUPERVIS<CN OF' JOHNNY MURAD A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT 1-----+-------------------------------t---+---+~--+-----J SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE Pl.ANS TO BRING THEM INTO CONFORMANCE WITH STANDARDS IN EFFECT. 67512 6-30-19 ~-r.~-ld CHECKED BY: /:.. A -7 •LJ DWG NO· 5- (9 -,;. r · I 0 ·--==c-· .. 1 ·e- J.M. ICITY ENGINEER R.C.E. 51152 DATE: 5657 2 ;? R.C.L EXPIRES DATE :r: