Loading...
HomeMy WebLinkAboutL1 - Noise Impact Analysis Beech Logistics Center NOISE AND VIBRATION ANALYSIS CITY OF FONTANA PREPARED BY: Bill Lawson, PE, INCE blawson@urbanxroads.com (949) 584-3148 JANUARY 9, 2023 14726-03 Noise Study Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study ii Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study iii TABLE OF CONTENTS TABLE OF CONTENTS ......................................................................................................................... III APPENDICES .................................................................................................................................... IV LIST OF EXHIBITS .............................................................................................................................. IV LIST OF TABLES ................................................................................................................................. V LIST OF ABBREVIATED TERMS ........................................................................................................... VI EXECUTIVE SUMMARY ....................................................................................................................... 1 1 INTRODUCTION ......................................................................................................................... 3 1.1 Site Location .................................................................................................................................. 3 1.2 Project Description ........................................................................................................................ 3 2 FUNDAMENTALS ....................................................................................................................... 7 2.1 Range of Noise .............................................................................................................................. 7 2.2 Noise Descriptors .......................................................................................................................... 8 2.3 Sound Propagation ........................................................................................................................ 8 2.4 Noise Control ................................................................................................................................ 9 2.5 Noise Barrier Attenuation ............................................................................................................. 9 2.6 Land Use Compatibility With Noise ............................................................................................ 10 2.7 Community Response to Noise ................................................................................................... 10 2.8 Vibration ..................................................................................................................................... 11 3 REGULATORY SETTING ............................................................................................................. 13 3.1 State of California Noise Requirements ...................................................................................... 13 3.2 City of Fontana General Plan Noise Element .............................................................................. 13 3.3 Operational Noise Standards ...................................................................................................... 14 3.4 Construction Noise Standards .................................................................................................... 14 3.5 Construction Vibration Standards ............................................................................................... 15 4 SIGNIFICANCE CRITERIA ........................................................................................................... 17 4.1 Noise Level Increases (Threshold A) ........................................................................................... 17 4.2 Vibration (Threshold B) ............................................................................................................... 18 4.3 CEQA Guidelines Not Further Analyzed (Threshold C) ............................................................... 18 4.4 Significance Criteria Summary .................................................................................................... 19 5 EXISTING NOISE LEVEL MEASUREMENTS .................................................................................. 21 5.1 Measurement Procedure and Criteria ........................................................................................ 21 5.2 Noise Measurement Locations ................................................................................................... 21 5.3 Noise Measurement Results ....................................................................................................... 22 6 TRAFFIC NOISE METHODS AND PROCEDURES ........................................................................... 25 6.1 FHWA Traffic Noise Prediction Model ........................................................................................ 25 7 OFF-SITE TRAFFIC NOISE ANALYSIS ........................................................................................... 29 7.1 Traffic Noise Contours ................................................................................................................ 29 7.2 Existing Project Traffic Noise Level Increases ............................................................................. 32 7.3 2024 Traffic Noise Level Increases .............................................................................................. 33 8 RECEIVER LOCATIONS .............................................................................................................. 35 9 OPERATIONAL NOISE ANALYSIS ............................................................................................... 37 Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study iv 9.1 Operational Noise Sources .......................................................................................................... 37 9.2 Reference Noise Levels ............................................................................................................... 37 9.3 CadnaA Noise Prediction Model ................................................................................................. 40 9.4 Project Operational Noise Levels ................................................................................................ 41 9.5 Project Operational Noise Level Compliance .............................................................................. 42 9.6 Project Operational Noise Level Increases ................................................................................. 43 10 CONSTRUCTION ANALYSIS ....................................................................................................... 45 10.1 Construction Noise Levels ........................................................................................................... 45 10.2 Construction Reference Noise Levels ......................................................................................... 45 10.3 Construction Noise Analysis ........................................................................................................ 47 10.4 Construction Noise Level Compliance ........................................................................................ 48 10.5 Nighttime Concrete Pour Noise Analysis .................................................................................... 49 10.6 Construction Vibration Analysis .................................................................................................. 52 11 REFERENCES ............................................................................................................................ 55 12 CERTIFICATIONS ...................................................................................................................... 57 APPENDICES APPENDIX 3.1: CITY OF FONTANA DEVELOPMENT CODE APPENDIX 5.1: STUDY AREA PHOTOS APPENDIX 5.2: NOISE LEVEL MEASUREMENT WORKSHEETS APPENDIX 7.1: OFF-SITE TRAFFIC NOISE CONTOURS APPENDIX 9.1: CADNAA OPERATIONAL NOISE MODEL INPUTS APPENDIX 10.1: CADNAA CONSTRUCTION NOISE MODEL INPUTS APPENDIX 10.2: CADNAA CONCRETE POUR NOISE MODEL INPUTS LIST OF EXHIBITS EXHIBIT 1-A: LOCATION MAP ............................................................................................................. 4 EXHIBIT 1-B: SITE PLAN ...................................................................................................................... 5 EXHIBIT 2-A: TYPICAL NOISE LEVELS ................................................................................................... 7 EXHIBIT 2-B: NOISE LEVEL INCREASE PERCEPTION ............................................................................ 10 EXHIBIT 2-C: TYPICAL LEVELS OF GROUND-BORNE VIBRATION .......................................................... 12 EXHIBIT 5-A: NOISE MEASUREMENT LOCATIONS .............................................................................. 23 EXHIBIT 8-A: RECEIVER LOCATIONS .................................................................................................. 36 EXHIBIT 9-A: OPERATIONAL NOISE SOURCE LOCATIONS ................................................................... 38 EXHIBIT 10-A: CONSTRUCTION NOISE SOURCE AND RECEIVER LOCATIONS ....................................... 46 EXHIBIT 10-B: NIGHTTIME CONCRETE POUR NOISE SOURCE AND RECEIVER LOCATIONS .................... 51 Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study v LIST OF TABLES TABLE ES-1: SUMMARY OF CEQA SIGNIFICANCE FINDINGS ................................................................. 1 TABLE 3-1: OPERATIONAL NOISE STANDARDS .................................................................................. 14 TABLE 4-1: SIGNIFICANCE CRITERIA SUMMARY ................................................................................. 19 TABLE 5-1: 24-HOUR AMBIENT NOISE LEVEL MEASUREMENTS ......................................................... 22 TABLE 6-1: OFF-SITE ROADWAY PARAMETERS ................................................................................. 26 TABLE 6-2: AVERAGE DAILY TRAFFIC VOLUMES ................................................................................ 27 TABLE 6-3: TIME OF DAY VEHICLE SPLITS .......................................................................................... 27 TABLE 6-4: WITHOUT PROJECT VEHICLE MIX .................................................................................... 27 TABLE 6-5: EXISTING WITH PROJECT VEHICLE MIX ............................................................................ 28 TABLE 6-6: OPENING YEAR CUMULATIVE 2024 WITH PROJECT VEHICLE MIX ..................................... 28 TABLE 7-1: EXISTING WITHOUT PROJECT CONTOURS ....................................................................... 29 TABLE 7-2: EXISTING WITH PROJECT CONTOURS .............................................................................. 30 TABLE 7-3: OYC 2024 WITHOUT PROJECT CONTOURS ....................................................................... 31 TABLE 7-4: OYC 2024 WITH PROJECT CONTOURS .............................................................................. 32 TABLE 7-5: EXISTING WITH PROJECT TRAFFIC NOISE LEVEL INCREASES .............................................. 33 TABLE 7-6: OYC 2024 WITH PROJECT TRAFFIC NOISE LEVEL INCREASES ............................................. 34 TABLE 9-1: REFERENCE NOISE LEVEL MEASUREMENTS ...................................................................... 39 TABLE 9-2: DAYTIME PROJECT OPERATIONAL NOISE LEVELS .............................................................. 41 TABLE 9-3: NIGHTTIME PROJECT OPERATIONAL NOISE LEVELS .......................................................... 42 TABLE 9-4: OPERATIONAL NOISE LEVEL COMPLIANCE ....................................................................... 42 TABLE 9-5: DAYTIME PROJECT OPERATIONAL NOISE LEVEL INCREASES ............................................. 43 TABLE 9-6: NIGHTTIME OPERATIONAL NOISE LEVEL INCREASES ........................................................ 44 TABLE 10-1: CONSTRUCTION REFERENCE NOISE LEVELS .................................................................... 47 TABLE 10-2: CONSTRUCTION EQUIPMENT NOISE LEVEL SUMMARY .................................................. 48 TABLE 10-3: TYPICAL CONSTRUCTION NOISE LEVEL COMPLIANCE ..................................................... 49 TABLE 10-4: NIGHTTIME CONCRETE POUR NOISE LEVEL COMPLIANCE .............................................. 50 TABLE 10-5: VIBRATION SOURCE LEVELS FOR CONSTRUCTION EQUIPMENT ...................................... 52 TABLE 10-6: PROJECT CONSTRUCTION VIBRATION LEVELS ................................................................ 53 Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study vi LIST OF ABBREVIATED TERMS (1) Reference ADT Average Daily Traffic ANSI American National Standards Institute Calveno California Vehicle Noise CEQA California Environmental Quality Act CNEL Community Noise Equivalent Level dBA A-weighted decibels FHWA Federal Highway Administration FTA Federal Transit Administration INCE Institute of Noise Control Engineering Leq Equivalent continuous (average) sound level Lmax Maximum level measured over the time interval Lmin Minimum level measured over the time interval mph Miles per hour OPR Office of Planning and Research PPV Peak Particle Velocity Project Beech Logistics Center REMEL Reference Energy Mean Emission Level RMS Root-mean-square VdB Vibration Decibels Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 1 EXECUTIVE SUMMARY Urban Crossroads, Inc. has prepared this noise study to determine the potential noise impacts and the necessary noise mitigation measures, if any, for the proposed Beech Logistics Center development (“Project”). The proposed Project includes the development of a single 168,759 square foot warehouse building. This study has been prepared to satisfy applicable City of Fontana standards and thresholds of significance based on guidance provided by Appendix G of the California Environmental Quality Act (CEQA) Guidelines. (1) The results of this Beech Logistics Center Noise and Vibration Analysis are summarized below based on the significance criteria in Section 4 of this report. Table ES-1 shows the findings of significance for each potential noise and/or vibration impact under CEQA before and after any required mitigation measures. TABLE ES-1: SUMMARY OF CEQA SIGNIFICANCE FINDINGS Analysis Report Section Significance Findings Unmitigated Mitigated Off-Site Traffic Noise 7 Less Than Significant - Operational Noise 9 Less Than Significant - Construction Noise 10 Less Than Significant - Nighttime Concrete Pour Less Than Significant - Construction Vibration Less Than Significant - Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 2 This page intentionally left blank Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 3 1 INTRODUCTION This noise analysis has been completed to determine the noise impacts associated with the development of the proposed Beech Logistics Center (“Project”). This noise study briefly describes the proposed Project, provides information regarding noise fundamentals, sets out the local regulatory setting, presents the study methods and procedures for transportation related CNEL traffic noise analysis, and evaluates the future exterior noise environment. In addition, this study includes an analysis of the potential Project-related long-term stationary-source operational noise and short-term construction noise and vibration impacts. 1.1 SITE LOCATION The proposed project is located north of Foothill Boulevard and west of Beech Avenue in the City of Fontana as shown on Exhibit 1-A. The proposed Project is located within the Southwest Industrial Park Specific Plan (SWIP) in the Jurupa North Research and Development District. 1.2 PROJECT DESCRIPTION The proposed Project is to consist of a single 168,759 square foot warehouse building. The Project is anticipated to be constructed in one phase by the year 2024. The preliminary site plan for the proposed Project is shown on Exhibit 1-B. The on-site Project-related noise sources are expected to include: loading dock activity, roof-top air conditioning units, trash enclosure activity, parking lot vehicle movements, and truck movements. This noise analysis is intended to describe noise level impacts associated with the expected typical operational activities at the Project site. Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 4 EXHIBIT 1-A: LOCATION MAP Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 5 EXHIBIT 1-B: SITE PLAN Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 6 This page intentionally left blank Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 7 2 FUNDAMENTALS Noise is simply defined as "unwanted sound." Sound becomes unwanted when it interferes with normal activities, when it causes actual physical harm or when it has adverse effects on health. Noise is measured on a logarithmic scale of sound pressure level known as a decibel (dB). A- weighted decibels (dBA) approximate the subjective response of the human ear to broad frequency noise source by discriminating against very low and very high frequencies of the audible spectrum. They are adjusted to reflect only those frequencies which are audible to the human ear. Exhibit 2-A presents a summary of the typical noise levels and their subjective loudness and effects that are described in more detail below. EXHIBIT 2-A: TYPICAL NOISE LEVELS Source: Environmental Protection Agency Office of Noise Abatement and Control, Information on Levels of Environmental Noise Requisite to Protect Public Health and Welfare with an Adequate Margin of Safety (EPA/ONAC 550/9-74-004) March 1974. 2.1 RANGE OF NOISE Since the range of intensities that the human ear can detect is so large, the scale frequently used to measure intensity is a scale based on multiples of 10, the logarithmic scale. The scale for measuring intensity is the decibel scale. Each interval of 10 decibels indicates a sound energy ten times greater than before, which is perceived by the human ear as being roughly twice as loud. (2) The most common sounds vary between 40 dBA (very quiet) to 100 dBA (very loud). Normal conversation at three feet is roughly at 60 dBA, while loud jet engine noises equate to 110 dBA Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 8 at approximately 1,000 feet, which can cause serious discomfort. (3) Another important aspect of noise is the duration of the sound and the way it is described and distributed in time. 2.2 NOISE DESCRIPTORS Environmental noise descriptors are generally based on averages, rather than instantaneous, noise levels. The most used metric is the equivalent level (Leq). Equivalent sound levels are not measured directly but are calculated from sound pressure levels typically measured in A- weighted decibels (dBA). The equivalent sound level (Leq) represents a steady state sound level containing the same total energy as a time varying signal over a given sample period and is commonly used to describe the “average” noise levels within the environment. Peak hour or average noise levels, while useful, do not completely describe a given noise environment. Noise levels lower than peak hour may be disturbing if they occur during times when quiet is most desirable, namely evening and nighttime (sleeping) hours. To account for this, the Community Noise Equivalent Level (CNEL), representing a composite 24-hour noise level is utilized. The CNEL is the weighted average of the intensity of a sound, with corrections for time of day, and averaged over 24 hours. The time-of-day corrections require the addition of 5 decibels to dBA Leq sound levels in the evening from 7:00 p.m. to 10:00 p.m., and the addition of 10 decibels to dBA Leq sound levels at night between 10:00 p.m. and 7:00 a.m. These additions are made to account for the noise sensitive time periods during the evening and night hours when noise can become more intrusive. CNEL does not represent the actual sound level heard at any time, but rather represents the total sound exposure. The City of Fontana relies on the 24-hour CNEL level to assess land use compatibility with transportation related noise sources. 2.3 SOUND PROPAGATION When sound propagates over a distance, it changes in level and frequency content. The way noise reduces with distance depends on the following factors. 2.3.1 GEOMETRIC SPREADING Sound from a localized source (i.e., a stationary point source) propagates uniformly outward in a spherical pattern. The sound level attenuates (or decreases) at a rate of 6 dB for each doubling of distance from a point source. Highways consist of several localized noise sources on a defined path and hence can be treated as a line source, which approximates the effect of several point sources. Noise from a line source propagates outward in a cylindrical pattern, often referred to as cylindrical spreading. Sound levels attenuate at a rate of 3 dB for each doubling of distance from a line source. (2) 2.3.2 GROUND ABSORPTION The propagation path of noise from a highway to a receiver is usually very close to the ground. Noise attenuation from ground absorption and reflective wave canceling adds to the attenuation associated with geometric spreading. Traditionally, the excess attenuation has also been expressed in terms of attenuation per doubling of distance. This approximation is usually Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 9 sufficiently accurate for distances of less than 200 ft. For acoustically hard sites (i.e., sites with a reflective surface between the source and the receiver, such as a parking lot or body of water), no excess ground attenuation is assumed. For acoustically absorptive or soft sites (i.e., those sites with an absorptive ground surface between the source and the receiver such as soft dirt, grass, or scattered bushes and trees), an excess ground attenuation value of 1.5 dB per doubling of distance is normally assumed. When added to the cylindrical spreading, the excess ground attenuation results in an overall drop-off rate of 4.5 dB per doubling of distance from a line source. (4) 2.3.3 ATMOSPHERIC EFFECTS Receivers located downwind from a source can be exposed to increased noise levels relative to calm conditions, whereas locations upwind can have lowered noise levels. Sound levels can be increased at large distances (e.g., more than 500 feet) due to atmospheric temperature inversion (i.e., increasing temperature with elevation). Other factors such as air temperature, humidity, and turbulence can also have significant effects. (2) 2.3.4 SHIELDING A large object or barrier in the path between a noise source and a receiver can substantially attenuate noise levels at the receiver. The amount of attenuation provided by shielding depends on the size of the object and the frequency content of the noise source. Shielding by trees and other such vegetation typically only has an “out of sight, out of mind” effect. That is, the perception of noise impact tends to decrease when vegetation blocks the line-of-sight to nearby residents. However, for vegetation to provide a substantial, or even noticeable, noise reduction, the vegetation area must be at least 15 feet in height, 100 feet wide and dense enough to completely obstruct the line-of-sight between the source and the receiver. This size of vegetation may provide up to 5 dBA of noise reduction. The Federal Highway Administration (FHWA) does not consider the planting of vegetation to be a noise abatement measure. (5) 2.4 NOISE CONTROL Noise control is the process of obtaining an acceptable noise environment for an observation point or receiver by controlling the noise source, transmission path, receiver, or all three. This concept is known as the source-path-receiver concept. In general, noise control measures can be applied to these three elements. 2.5 NOISE BARRIER ATTENUATION Effective noise barriers can reduce noise levels by 10 to 15 dBA, cutting the loudness of traffic noise in half. A noise barrier is most effective when placed close to the noise source or receiver. Noise barriers, however, do have limitations. For a noise barrier to work, it must block the line- of-sight path of sound from the noise source. Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 10 2.6 LAND USE COMPATIBILITY WITH NOISE Some land uses are more tolerant of noise than others. For example, schools, hospitals, churches, and residences are more sensitive to noise intrusion than are commercial or industrial developments and related activities. As ambient noise levels affect the perceived amenity or livability of a development, so too can the mismanagement of noise impacts impair the economic health and growth potential of a community by reducing the area’s desirability as a place to live, shop and work. For this reason, land use compatibility with the noise environment is an important consideration in the planning and design process. The FHWA encourages State and Local government to regulate land development in such a way that noise-sensitive land uses are either prohibited from being located adjacent to a highway, or that the developments are planned, designed, and constructed in such a way that noise impacts are minimized. (6) 2.7 COMMUNITY RESPONSE TO NOISE Approximately sixteen percent of the population has a very low tolerance for noise and will object to any noise not of their making. Consequently, even in the quietest environment, some complaints may occur. Twenty to thirty percent of the population will not complain even in very severe noise environments. (7 pp. 8-6) Thus, a variety of reactions can be expected from people exposed to any given noise environment. Surveys have shown that community response to noise varies from no reaction to vigorous action for newly introduced noises averaging from 10 dB below existing to 25 dB above existing. (8) According to research originally published in the Noise Effects Handbook (7), the percentage of high annoyance ranges from approximately 0 percent at 45 dB or less, 10 percent are highly annoyed around 60 dB, and increases rapidly to approximately 70 percent being highly annoyed at approximately 85 dB or greater. Despite this variability in behavior on an individual level, the population can be expected to exhibit the following responses to changes in noise levels as shown on Exhibit 2-B. A change of 3 dBA is considered barely perceptible, and changes of 5 dBA are considered readily perceptible. (4) EXHIBIT 2-B: NOISE LEVEL INCREASE PERCEPTION 0 1 2 3 4 5 6 7 8 9 10 Just Perceptible Barely Perceptible Readily Perceptible Twice as Loud Noise Level Increase (dBA) Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 11 2.8 VIBRATION Per the Federal Transit Administration (FTA) Transit Noise Impact and Vibration Impact Assessment Manual (8) , vibration is the periodic oscillation of a medium or object. The rumbling sound caused by the vibration of room surfaces is called structure-borne noise. Sources of ground-borne vibrations include natural phenomena (e.g., earthquakes, volcanic eruptions, sea waves, landslides) or human-made causes (e.g., explosions, machinery, traffic, trains, construction equipment). Vibration sources may be continuous, such as factory machinery, or transient, such as explosions. As is the case with airborne sound, ground-borne vibrations may be described by amplitude and frequency. There are several different methods that are used to quantify vibration. The peak particle velocity (PPV) is defined as the maximum instantaneous peak of the vibration signal. The PPV is most frequently used to describe vibration impacts to buildings but is not always suitable for evaluating human response (annoyance) because it takes some time for the human body to respond to vibration signals. Instead, the human body responds to average vibration amplitude often described as the root mean square (RMS). The RMS amplitude is defined as the average of the squared amplitude of the signal and is most frequently used to describe the effect of vibration on the human body. Decibel notation (VdB) is commonly used to measure RMS. Decibel notation (VdB) serves to reduce the range of numbers used to describe human response to vibration. Typically, ground-borne vibration generated by man-made activities attenuates rapidly with distance from the source of the vibration. Sensitive receivers for vibration include structures (especially older masonry structures), people (especially residents, the elderly, and sick), and vibration-sensitive equipment and/or activities. The background vibration-velocity level in residential areas is generally 50 VdB. Ground-borne vibration is normally perceptible to humans at approximately 65 VdB. For most people, a vibration-velocity level of 75 VdB is the approximate dividing line between barely perceptible and distinctly perceptible levels. Typical outdoor sources of perceptible ground-borne vibration are construction equipment, steel-wheeled trains, and traffic on rough roads. If a roadway is smooth, the ground-borne vibration is rarely perceptible. The range of interest is from approximately 50 VdB, which is the typical background vibration-velocity level, to 100 VdB, which is the general threshold where minor damage can occur in fragile buildings. Exhibit 2-C illustrates common vibration sources and the human and structural response to ground-borne vibration. Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 12 EXHIBIT 2-C: TYPICAL LEVELS OF GROUND-BORNE VIBRATION Source: Federal Transit Administration (FTA) Transit Noise and Vibration Impact Assessment Manual. Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 13 3 REGULATORY SETTING The federal government, the State of California, various county governments, and most municipalities in the state have established standards and ordinances to control noise. In most areas, automobile and truck traffic is the major source of environmental noise. Traffic activity generally produces an average sound level that remains constant with time. Air and rail traffic, and commercial and industrial activities are also major sources of noise in some areas. Federal, state, and local agencies regulate different aspects of environmental noise. Federal and state agencies generally set noise standards for mobile sources such as aircraft and motor vehicles, while regulation of stationary sources is left to local agencies. 3.1 STATE OF CALIFORNIA NOISE REQUIREMENTS The State of California regulates freeway noise, sets standards for sound transmission, provides occupational noise control criteria, identifies noise standards, and provides guidance for local land use compatibility. State law requires that each county and city adopt a General Plan that includes a Noise Element which is to be prepared per guidelines adopted by the Governor’s Office of Planning and Research (OPR). (9) The purpose of the Noise Element is to limit the exposure of the community to excessive noise levels. In addition, the California Environmental Quality Act (CEQA) requires that all known environmental effects of a project be analyzed, including environmental noise impacts. 3.2 CITY OF FONTANA GENERAL PLAN NOISE ELEMENT The City of Fontana General Plan was updated on November 13, 2018. (11) To protect residents from the negative effect of “spillover” noise (Goal #10), the City of Fontana has identified the following policies in the General Plan Noise Element: Policy Residential land uses and areas identified as noise-sensitive shall be protected from excessive noise from non-transportation sources including industrial, commercial, and residential activities and equipment. Actions A. Projects located in commercial areas shall not exceed stationary- source noise standards at the property line of proximate residential or commercial uses. B. Industrial uses shall not exceed commercial or residential stationary source noise standards at the most proximate land uses. C. Non-transportation noise shall be considered in land use planning decisions. D. Construction shall be performed as quietly as feasible when performed in proximity to residential or other noise sensitive land uses. Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 14 3.3 OPERATIONAL NOISE STANDARDS To analyze noise impacts originating from a designated fixed location or private property such as the Beech Logistics Center Project, stationary-source (operational) noise such as the expected loading dock activity, roof-top air conditioning units, trash enclosure activity, parking lot vehicle movements, and truck movements are typically evaluated against standards established under a jurisdiction’s Municipal Code. The City of Fontana noise control guidelines for determining and mitigating non-transportation or stationary noise source impacts from operations in neighboring residential areas are found in the Zoning and Development Code (Section 30-543), provided in Appendix 3.1. For industrial zoning districts, Section 30-543 indicates that no person shall create or cause to be created any sound which exceeds the noise levels in this section as measured at the property line of any residentially zoned property. The performance standards found in Section 30-543 limit the exterior noise level to 70 dBA Leq during the daytime hours, and 65 dBA Leq during the nighttime hours at sensitive receiver locations as shown on Table 3-1. (12) TABLE 3-1: OPERATIONAL NOISE STANDARDS Jurisdiction Land use Noise Level Standards (dBA Leq)2 Daytime Nighttime City of Fontana1 Residential 70 65 1 Section 30-543 of the City of Fontana Development Code (Appendix 3.1). 2 Leq represents a steady state sound level containing the same total energy as a time varying signal over a given sample period. "Daytime" = 7:00 a.m. to 10:00 p.m.; "Nighttime" = 10:00 p.m. to 7:00 a.m. 3.4 CONSTRUCTION NOISE STANDARDS The City of Fontana has set restrictions to control noise impacts associated with the construction of the proposed Project. According to Section 18-63[b][7] of the city’s Municipal Code, Construction or repairing of buildings or structures, construction activity is limited: between the hours of 7:00 a.m. and 6:00 p.m. on weekdays and between the hours of 8:00 a.m. and 5:00 p.m. on Saturdays except in the case of urgent necessity. (13) Project construction noise levels are, therefore, considered exempt from municipal regulation if activities occur within the hours specified in the City of Fontana Municipal Code, Section 18-63[7] of 7:00 a.m. to 6:00 p.m. on weekdays and between the hours of 8:00 a.m. to 5:00 p.m. on Saturdays. However, neither the General Plan nor the Municipal Code establish numeric maximum acceptable construction source noise levels at potentially affected receivers for CEQA analysis purposes. Therefore, a numerical construction threshold based on Federal Transit Administration (FTA) Transit Noise and Vibration Impact Assessment Manual is used for analysis of daytime construction impacts, as discussed below. According to the FTA, local noise ordinances are typically not very useful in evaluating construction noise. They usually relate to nuisance and hours of allowed activity, and sometimes specify limits in terms of maximum levels, but are generally not practical for assessing the impact of a construction project. Project construction noise criteria should account for the existing noise Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 15 environment, the absolute noise levels during construction activities, the duration of the construction, and the adjacent land use. Due to the lack of standardized construction noise thresholds, the FTA provides guidelines that can be considered reasonable criteria for construction noise assessment. The FTA considers a daytime exterior construction noise level of 80 dBA Leq as a reasonable threshold for noise sensitive residential land use with a nighttime exterior construction noise level of 70 dBA Leq (8 p. 179). 3.5 CONSTRUCTION VIBRATION STANDARDS Construction activity can result in varying degrees of ground-borne vibration, depending on the equipment and methods used, distance to the affected structures and soil type. Construction vibration is generally associated with pile driving and rock blasting. Other construction equipment such as air compressors, light trucks, hydraulic loaders, etc., generates little or no ground vibration (8). To analyze vibration impacts originating from the operation and construction of the Beech Logistics Center, vibration-generating activities are appropriately evaluated against standards established under the Municipal Code, if such standards exist. However, the City of Fontana does not identify specific construction vibration level limits. Therefore, for analysis purposes, the Caltrans Transportation and Construction Vibration Guidance Manual, (12 p. 38) Table 19, vibration damage are used in this noise study to assess potential temporary construction-related impacts at adjacent building locations. The nearest noise sensitive buildings adjacent to the Project site can best be described as “older residential structures” with a maximum acceptable continuous vibration threshold of 0.3 PPV (in/sec). Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 16 This page intentionally left blank Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 17 4 SIGNIFICANCE CRITERIA The following significance criteria are based on currently adopted guidance provided by Appendix G of the California Environmental Quality Act (CEQA) Guidelines. (1) For the purposes of this report, impacts would be potentially significant if the Project results in or causes: A. Generation of a substantial temporary or permanent increase in ambient noise levels in the vicinity of the project in excess of standards established in the local general plan or noise ordinance, or applicable standards of other agencies? B. Generation of excessive ground-borne vibration or ground-borne noise levels? C. For a project located within the vicinity of a private airstrip or an airport land use plan or, where such a plan has not been adopted, within two miles of a public airport or public use airport, would the project expose people residing or working in the project area to excessive noise levels? 4.1 NOISE LEVEL INCREASES (THRESHOLD A) Noise level increases resulting from the Project are evaluated based on the Appendix G CEQA Guidelines. Under CEQA, consideration must be given to the magnitude of the increase, the existing baseline ambient noise levels, and the location of receivers to determine if a noise increase represents a significant adverse environmental impact. This approach recognizes that there is no single noise increase that renders the noise impact significant. (15) This is primarily because of the wide variation in individual thresholds of annoyance and differing individual experiences with noise. Thus, an important way of determining a person’s subjective reaction to a new noise is the comparison of it to the existing environment to which one has adapted—the so-called ambient environment. In general, the more a new noise exceeds the previously existing ambient noise level, the less acceptable the new noise will typically be judged. The Federal Interagency Committee on Noise (FICON) (16) developed guidance to be used for the assessment of project-generated increases in noise levels that consider the ambient noise level. The FICON recommendations are based on studies that relate aircraft noise levels to the percentage of persons highly annoyed by aircraft noise. Although the FICON recommendations were specifically developed to assess aircraft noise impacts, these recommendations are often used in environmental noise impact assessments involving the use of cumulative noise exposure metrics, such as the average-daily noise level (CNEL) and equivalent continuous noise level (Leq). As previously stated, the approach used in this noise study recognizes that there is no single noise increase that renders the noise impact significant, based on a 2008 California Court of Appeal ruling on Gray v. County of Madera. (15) For example, if the ambient noise environment is quiet (<60 dBA) and the new noise source greatly increases the noise levels, an impact may occur if the noise criteria may be exceeded. Therefore, for this analysis, a readily perceptible 5 dBA or greater project-related noise level increase is considered a significant impact when the without project noise levels are below 60 dBA. Per the FICON, in areas where the without project noise levels range from 60 to 65 dBA, a 3 dBA barely perceptible noise level increase appears to be appropriate for most people. When the without project noise levels already exceed 65 dBA, any Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 18 increase in community noise louder than 1.5 dBA or greater is considered a significant impact if the noise criteria for a given land use is exceeded, since it likely contributes to an existing noise exposure exceedance. The FICON guidance provides an established source of criteria to assess the impacts of substantial temporary or permanent increase in baseline ambient noise levels. Based on the FICON criteria, the amount to which a given noise level increase is considered acceptable is reduced when the without Project (baseline) noise levels are already shown to exceed certain land-use specific exterior noise level criteria. The specific levels are based on typical responses to noise level increases of 5 dBA or readily perceptible, 3 dBA or barely perceptible, and 1.5 dBA depending on the underlying without Project noise levels for noise- sensitive uses. These levels of increases and their perceived acceptance are consistent with guidance provided by both the Federal Highway Administration (4 p. 9) and Caltrans (17 p. 2_48). 4.2 VIBRATION (THRESHOLD B) As described in Section 3.5, the vibration impacts originating from the construction of Beech Logistics Center, vibration-generating activities are appropriately evaluated using the Caltrans vibration damage thresholds to assess potential temporary construction-related impacts at adjacent building locations. The nearest noise sensitive buildings adjacent to the Project site can best be described as “older residential structures” with a maximum acceptable continuous vibration threshold of 0.3 PPV (in/sec). 4.3 CEQA GUIDELINES NOT FURTHER ANALYZED (THRESHOLD C) CEQA Noise Threshold C applies when there are nearby public and private airports and/or air strips and focuses on land use compatibility of the Project to nearby airports and airstrips. The Project site is not located within two miles of an airport or airstrip. The closest airport is the Ontario International Airport located roughly 7 miles southwest of the Project site. As such, the Project site would not be exposed to excessive noise levels from airport operations, and therefore, impacts are considered less than significant, and no further noise analysis is conducted in relation to Appendix G to the CEQA Guidelines, Noise Threshold C. Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 19 4.4 SIGNIFICANCE CRITERIA SUMMARY Noise impacts shall be considered significant if any of the following occur as a direct result of the proposed Project. Table 4-1 shows the significance criteria summary matrix that includes the allowable criteria used to identify potentially significant incremental noise level increases. TABLE 4-1: SIGNIFICANCE CRITERIA SUMMARY Analysis Receiving Land Use Condition(s) Significance Criteria Daytime Nighttime Off-Site Noise- Sensitive1 if ambient is < 60 dBA CNEL ≥ 5 dBA CNEL Project increase if ambient is 60 - 65 dBA CNEL ≥ 3 dBA CNEL Project increase if ambient is > 65 dBA CNEL ≥ 1.5 dBA CNEL Project increase Operational Adjacent Uses Exterior Noise Level Standards2 70 dBA Leq 65 dBA Leq Noise- Sensitive1 If ambient is < 60 dBA Leq ≥ 5 dBA Leq Project increase If ambient is 60 - 65 dBA Leq ≥ 3 dBA Leq Project increase If ambient is > 65 dBA Leq ≥ 1.5 dBA Leq Project increase Construction Adjacent Uses Exempt from the exterior noise level standards between the hours 7:00 a.m. to 6:00 p.m. on weekdays and between the hours of 8:00 a.m. to 5:00 p.m. on Saturdays3 Noise Level Threshold4 80 dBA Leq 70 dBA Leq Vibration Level Threshold5 0.3 PPV (in/sec) 1 FICON, 1992. 2 Based on Section 30-543 of the City of Fontana Municipal Code. 3 Based on Sections 18-63(7) and 30-543 of the City of Fontana Municipal Code. 4 Federal Transit Administration, Transit Noise and Vibration Impact Assessment Manual. 5 Caltrans Transportation and Construction Vibration Guidance Manual, April 2020, Table 19. "Daytime" = 7:00 a.m. to 10:00 p.m.; "Nighttime" = 10:00 p.m. to 7:00 a.m. Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 20 This page intentionally left blank Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 21 5 EXISTING NOISE LEVEL MEASUREMENTS To assess the existing noise level environment, 24-hour noise level measurements were taken at six locations in the Project study area. The receiver locations were selected to describe and document the existing noise environment within the Project study area. Exhibit 5-A provides the boundaries of the Project study area and the noise level measurement locations. To fully describe the existing noise conditions, noise level measurements were collected by Urban Crossroads, Inc. on Wednesday, October 27th, 2021. Appendix 5.1 includes study area photos. 5.1 MEASUREMENT PROCEDURE AND CRITERIA To describe the existing noise environment, the hourly noise levels were measured during typical weekday conditions over a 24-hour period. By collecting individual hourly noise level measurements, it is possible to describe the equivalent daytime and nighttime hourly noise levels. The long-term noise readings were recorded using Piccolo Type 2 integrating sound level meter and dataloggers. The Piccolo sound level meters were calibrated using a Larson-Davis calibrator, Model CAL 150. All noise meters were programmed in "slow" mode to record noise levels in "A" weighted form. The sound level meters and microphones were equipped with a windscreen during all measurements. All noise level measurement equipment satisfies the American National Standards Institute (ANSI) standard specifications for sound level meters ANSI S1.4-2014/IEC 61672-1:2013. (18) 5.2 NOISE MEASUREMENT LOCATIONS The long-term noise level measurements were positioned as close to the nearest sensitive receiver locations as possible to assess the existing ambient hourly noise levels surrounding the Project site. Both Caltrans and the FTA recognize that it is not reasonable to collect noise level measurements that can fully represent every part of a private yard, patio, deck, or balcony normally used for human activity when estimating impacts for new development projects. This is demonstrated in the Caltrans general site location guidelines which indicate that, sites must be free of noise contamination by sources other than sources of interest. Avoid sites located near sources such as barking dogs, lawnmowers, pool pumps, and air conditioners unless it is the express intent of the analyst to measure these sources. (2) Further, FTA guidance states, that it is not necessary nor recommended that existing noise exposure be determined by measuring at every noise-sensitive location in the project area. Rather, the recommended approach is to characterize the noise environment for clusters of sites based on measurements or estimates at representative locations in the community. (8) Based on recommendations of Caltrans and the FTA, it is not necessary to collect measurements at each individual building or residence, because each receiver measurement represents a group of buildings that share acoustical equivalence. (8) In other words, the area represented by the receiver shares similar shielding, terrain, and geometric relationship to the reference noise source. Receivers represent a location of noise sensitive areas and are used to estimate the future noise level impacts. Collecting reference ambient noise level measurements at the nearby sensitive receiver locations allows for a comparison of the before and after Project noise levels Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 22 and is necessary to assess potential noise impacts due to the Project’s contribution to the ambient noise levels. 5.3 NOISE MEASUREMENT RESULTS The noise measurements presented below focus on the average or equivalent sound levels (Leq). The equivalent sound level (Leq) represents a steady state sound level containing the same total energy as a time varying signal over a given sample period. Table 5-1 identifies the hourly daytime (7:00 a.m. to 10:00 p.m.) and nighttime (10:00 p.m. to 7:00 a.m.) noise levels at each noise level measurement location. TABLE 5-1: 24-HOUR AMBIENT NOISE LEVEL MEASUREMENTS Location1 Description Energy Average Noise Level (dBA Leq)2 Daytime Nighttime L1 Located northwest of the Project site near single-family residence at 15247 Montanez Street. 51.2 50.7 L2 Located north of the Project site near a child's playground southwest of Parsley Leaf Place. 51.6 51.3 L3 Located northeast of the Project site near single-family residence at 15459 Vanilla Bean Lane. 65.0 61.0 L4 Located southeast of the Project site near single-family residence at 15357 Foothill Boulevard. 69.9 65.9 L5 Located southwest of the Project site near Sunset Motel at 15243 Foothill Boulevard. 71.5 67.3 L6 Located southwest of the Project site near Forty Winks Motel at 15210 Foothill Boulevard. 54.0 54.5 1 See Exhibit 5-A for the noise level measurement locations. 2 Energy (logarithmic) average levels. The long-term 24-hour measurement worksheets are included in Appendix 5.2. "Daytime" = 7:00 a.m. to 10:00 p.m.; "Nighttime" = 10:00 p.m. to 7:00 a.m. Table 5-1 provides the (energy average) noise levels used to describe the daytime and nighttime ambient conditions. These daytime and nighttime energy average noise levels represent the average of all hourly noise levels observed during these time periods expressed as a single number. Appendix 5.2 provides summary worksheets of the noise levels for each hour as well as the minimum, maximum, L1, L2, L5, L8, L25, L50, L90, L95, and L99 percentile noise levels observed during the daytime and nighttime periods. Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 23 EXHIBIT 5-A: NOISE MEASUREMENT LOCATIONS Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 24 This page intentionally left blank Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 25 6 TRAFFIC NOISE METHODS AND PROCEDURES The following section outlines the methods and procedures used to estimate and analyze the future traffic noise environment. Consistent with the Land Use Compatibility Criteria, all transportation related noise levels are presented in terms of the 24-hour CNEL’s. 6.1 FHWA TRAFFIC NOISE PREDICTION MODEL The expected roadway noise level increases from vehicular traffic were calculated by Urban Crossroads, Inc. using a computer program that replicates the Federal Highway Administration (FHWA) Traffic Noise Prediction Model- FHWA-RD-77-108. (19) This methodology is commonly used to describe the off-site traffic noise levels throughout California and is consistent with the City of Fontana General Plan Noise Element. The FHWA Model arrives at a predicted noise level through a series of adjustments to the Reference Energy Mean Emission Level (REMEL). In California the national REMELs are substituted with the California Vehicle Noise (Calveno) Emission Levels. (20) Adjustments are then made to the REMEL to account for: the roadway classification (e.g., collector, secondary, major or arterial), the roadway active width (i.e., the distance between the center of the outermost travel lanes on each side of the roadway), the total average daily traffic (ADT), the travel speed, the percentages of automobiles, medium trucks, and heavy trucks in the traffic volume, the roadway grade, the angle of view (e.g., whether the roadway view is blocked), the site conditions ("hard" or "soft" relates to the absorption of the ground, pavement, or landscaping), and the percentage of total ADT which flows each hour throughout a 24-hour period. Research conducted by Caltrans has shown that the use of soft site conditions is appropriate for the application of the FHWA traffic noise prediction model used in this analysis. (21) 6.1.1 OFF-SITE TRAFFIC NOISE PREDICTION MODEL INPUTS Table 6-1 presents the roadway parameters used to assess the Project’s off-site transportation noise impacts. Table 6-1 identifies the 14 off-site study area roadway segments, the distance from the centerline to adjacent land use based on the functional roadway classifications per the City of Fontana General Plan, and the posted vehicle speeds. The ADT volumes used in this study area presented on Table 6-2 are based on Beech Logistics Center Traffic Study by Urban Crossroads, Inc. for the following traffic scenarios. (21) 1. Existing (E) 2. Existing + Project (E+P) 3. Opening Year Cumulative (2024) without Project (OYC) 4. Opening Year Cumulative (2024) with Project (OYCP) Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 26 The ADT volumes vary for each roadway segment based on the existing traffic volumes and the combination of project traffic distributions. This analysis relies on a comparative evaluation of the off-site traffic noise impacts at the boundary of the right-of-way of the receiving adjacent land use, without and with project ADT traffic volumes from the Project traffic study. TABLE 6-1: OFF-SITE ROADWAY PARAMETERS ID Roadway Segment Classification1 Receiving Land Use2 Distance from Centerline to Receiving Land Use (Feet)3 Vehicle Speed (mph) 1 Cherry Av. n/o Foothill Bl. (SR-66) Major Non-Sensitive 66' 55 2 Cherry Av. s/o Foothill Bl. (SR-66) Major Sensitive 66' 55 3 Redwood Av. s/o Foothill Bl. (SR-66) Collector Sensitive 34' 45 4 Hemlock Av. s/o Foothill Bl. (SR-66) Collector Sensitive 34' 45 5 Almeria Av. n/o Foothill Bl. (SR-66) Collector Sensitive 34' 45 6 Citrus Av. n/o Foothill Bl. (SR-66) Primary Sensitive 52' 50 7 Citrus Av. s/o Foothill Bl. (SR-66) Primary Sensitive 52' 50 8 Foothill Bl. (SR-66) w/o Cherry Av. Major Sensitive 66' 55 9 Foothill Bl. (SR-66) e/o Cherry Av. Major Non-Sensitive 66' 55 10 Foothill Bl. (SR-66) w/o Hemlock Av. Major Sensitive 66' 55 11 Foothill Bl. (SR-66) e/o Hemlock Av. Major Sensitive 66' 55 12 Foothill Bl. (SR-66) e/o Beech Av. Major Sensitive 66' 55 13 Foothill Bl. (SR-66) w/o Citrus Av. Major Non-Sensitive 66' 55 14 Foothill Bl. (SR-66) e/o Citrus Av. Major Sensitive 66' 55 1 Beech Logistics Center Traffic Study, Urban Crossroads, Inc. 2 Based on a review of existing aerial imagery. Noise sensitive uses limited to existing residential land uses. 3 Distance to receiving land use is based upon the right-of-way distances. To quantify the off-site noise levels, the Project related truck trips were added to the heavy truck category in the FHWA noise prediction model. The addition of the Project related truck trips increases the percentage of heavy trucks in the vehicle mix. This approach recognizes that the FHWA noise prediction model is significantly influenced by the number of heavy trucks in the vehicle mix. Table 6-3 provides the time of day (daytime, evening, and nighttime) vehicle splits. Table 6-4 shows the traffic flow by vehicle type (vehicle mix) used for all without Project traffic scenarios, and Tables 6-5 to 6-6 show the vehicle mixes used for the with Project traffic scenarios. Due to the added Project truck trips, the increase in Project traffic volumes and the distributions of trucks on the study area road segments, the percentage of autos, medium trucks and heavy trucks will vary for each of the traffic scenarios. This explains why the existing and future traffic volumes and vehicle mixes vary between seemingly identical study area roadway segments. Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 27 TABLE 6-2: AVERAGE DAILY TRAFFIC VOLUMES ID Roadway Segment Average Daily Traffic Volumes1 Existing Opening Year (2023) Without Project With Project Without Project With Project 1 Cherry Av. n/o Foothill Bl. (SR-66) 27,002 27,054 30,847 30,898 2 Cherry Av. s/o Foothill Bl. (SR-66) 25,477 25,556 28,966 29,045 3 Redwood Av. s/o Foothill Bl. (SR-66) 3,640 3,656 3,935 3,951 4 Hemlock Av. s/o Foothill Bl. (SR-66) 2,048 2,065 2,279 2,296 5 Almeria Av. n/o Foothill Bl. (SR-66) 4,370 4,404 5,207 5,240 6 Citrus Av. n/o Foothill Bl. (SR-66) 21,394 21,453 23,154 23,214 7 Citrus Av. s/o Foothill Bl. (SR-66) 23,286 23,366 25,070 25,151 8 Foothill Bl. (SR-66) w/o Cherry Av. 29,038 29,077 33,692 33,730 9 Foothill Bl. (SR-66) e/o Cherry Av. 29,143 29,328 37,778 37,963 10 Foothill Bl. (SR-66) w/o Hemlock Av. 25,529 25,731 28,475 28,677 11 Foothill Bl. (SR-66) e/o Hemlock Av. 26,742 26,961 31,783 32,002 12 Foothill Bl. (SR-66) e/o Beech Av. 25,908 26,115 31,300 31,300 13 Foothill Bl. (SR-66) w/o Citrus Av. 26,377 26,551 32,059 32,059 14 Foothill Bl. (SR-66) e/o Citrus Av. 25,973 26,006 30,922 30,922 1 Beech Logistics Center Traffic Study, Urban Crossroads, Inc TABLE 6-3: TIME OF DAY VEHICLE SPLITS Vehicle Type Time of Day Splits1 Total of Time of Day Splits Daytime Evening Nighttime Autos 76.57% 12.78% 10.64% 100.00% Medium Trucks 84.53% 3.60% 11.87% 100.00% Heavy Trucks 76.09% 2.17% 21.74% 100.00% 1 Based on the May 24, 2022, 24-hour directional vehicle classification count collected on Foothill Boulevard. west of Beech Avenue (Beech Logistics Center Traffic Analysis, Urban Crossroads, Inc.) "Daytime" = 7:00 a.m. to 7:00 p.m.; "Evening" = 7:00 p.m. to 10:00 p.m.; "Nighttime" = 10:00 p.m. to 7:00 a.m. TABLE 6-4: WITHOUT PROJECT VEHICLE MIX Classification Total % Traffic Flow1 Total Autos Medium Trucks Heavy Trucks All Segments 96.33% 2.01% 1.66% 100.00% 1 Based on the May 24, 2022, 24-hour directional vehicle classification count collected on Foothill Boulevard. west of Beech Avenue (Beech Logistics Center Traffic Analysis, Urban Crossroads, Inc.) Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 28 TABLE 6-5: EXISTING WITH PROJECT VEHICLE MIX ID Roadway Segment With Project1 Autos Medium Trucks Heavy Trucks Total2 1 Cherry Av. n/o Foothill Bl. (SR-66) 96.27% 2.02% 1.71% 100.00% 2 Cherry Av. s/o Foothill Bl. (SR-66) 96.16% 2.04% 1.80% 100.00% 3 Redwood Av. s/o Foothill Bl. (SR-66) 96.34% 2.00% 1.66% 100.00% 4 Hemlock Av. s/o Foothill Bl. (SR-66) 96.36% 1.99% 1.65% 100.00% 5 Almeria Av. n/o Foothill Bl. (SR-66) 96.36% 1.99% 1.65% 100.00% 6 Citrus Av. n/o Foothill Bl. (SR-66) 96.30% 2.01% 1.69% 100.00% 7 Citrus Av. s/o Foothill Bl. (SR-66) 96.28% 2.01% 1.70% 100.00% 8 Foothill Bl. (SR-66) w/o Cherry Av. 96.32% 2.01% 1.67% 100.00% 9 Foothill Bl. (SR-66) e/o Cherry Av. 96.12% 2.04% 1.84% 100.00% 10 Foothill Bl. (SR-66) w/o Hemlock Av. 96.09% 2.04% 1.87% 100.00% 11 Foothill Bl. (SR-66) e/o Hemlock Av. 96.11% 2.04% 1.85% 100.00% 12 Foothill Bl. (SR-66) e/o Beech Av. 96.27% 2.01% 1.72% 100.00% 13 Foothill Bl. (SR-66) w/o Citrus Av. 96.27% 2.01% 1.72% 100.00% 14 Foothill Bl. (SR-66) e/o Citrus Av. 96.33% 2.01% 1.66% 100.00% 1 Total of vehicle mix percentage values rounded to the nearest one-hundredth. TABLE 6-6: OPENING YEAR CUMULATIVE 2024 WITH PROJECT VEHICLE MIX ID Roadway Segment With Project1 Autos Medium Trucks Heavy Trucks Total2 1 Cherry Av. n/o Foothill Bl. (SR-66) 96.27% 2.02% 1.71% 100.00% 2 Cherry Av. s/o Foothill Bl. (SR-66) 96.18% 2.03% 1.79% 100.00% 3 Redwood Av. s/o Foothill Bl. (SR-66) 96.34% 2.00% 1.66% 100.00% 4 Hemlock Av. s/o Foothill Bl. (SR-66) 96.35% 2.00% 1.65% 100.00% 5 Almeria Av. n/o Foothill Bl. (SR-66) 96.35% 2.00% 1.65% 100.00% 6 Citrus Av. n/o Foothill Bl. (SR-66) 96.30% 2.01% 1.69% 100.00% 7 Citrus Av. s/o Foothill Bl. (SR-66) 96.29% 2.01% 1.70% 100.00% 8 Foothill Bl. (SR-66) w/o Cherry Av. 96.32% 2.01% 1.67% 100.00% 9 Foothill Bl. (SR-66) e/o Cherry Av. 96.17% 2.03% 1.80% 100.00% 10 Foothill Bl. (SR-66) w/o Hemlock Av. 96.12% 2.04% 1.84% 100.00% 11 Foothill Bl. (SR-66) e/o Hemlock Av. 96.14% 2.03% 1.82% 100.00% 12 Foothill Bl. (SR-66) e/o Beech Av. 96.33% 2.01% 1.66% 100.00% 13 Foothill Bl. (SR-66) w/o Citrus Av. 96.33% 2.01% 1.66% 100.00% 14 Foothill Bl. (SR-66) e/o Citrus Av. 96.33% 2.01% 1.66% 100.00% 1 Total of vehicle mix percentage values rounded to the nearest one-hundredth. Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 29 7 OFF-SITE TRAFFIC NOISE ANALYSIS To assess the off-site transportation CNEL noise level impacts associated with the proposed Project, noise contours were developed based on the Beech Logistics Center Traffic Study. (21) Noise contour boundaries represent the equal levels of noise exposure and are measured in CNEL from the center of the roadway. 7.1 TRAFFIC NOISE CONTOURS Noise contours were used to assess the Project's incremental traffic-related noise impacts at land uses adjacent to roadways conveying Project traffic. The noise contours represent the distance to noise levels of a constant value and are measured from the center of the roadway for the 70, 65, and 60 dBA noise levels. The noise contours do not consider the effect of any existing noise barriers or topography that may attenuate ambient noise levels. In addition, because the noise contours reflect modeling of vehicular noise on area roadways, they appropriately do not reflect noise contributions from the surrounding stationary noise sources within the Project study area. Tables 7-1 to 7-4 present a summary of the exterior traffic noise levels for each traffic condition. Appendix 7.1 includes the traffic noise level contours worksheets. TABLE 7-1: EXISTING WITHOUT PROJECT CONTOURS ID Road Segment Receiving Land Use1 CNEL at Receiving Land Use (dBA)2 Distance to Contour from Centerline (Feet) 70 dBA CNEL 65 dBA CNEL 60 dBA CNEL 1 Cherry Av. n/o Foothill Bl. (SR-66) Non-Sensitive 74.6 134 288 621 2 Cherry Av. s/o Foothill Bl. (SR-66) Sensitive 74.4 129 277 598 3 Redwood Av. s/o Foothill Bl. (SR-66) Sensitive 66.4 RW RW 90 4 Hemlock Av. s/o Foothill Bl. (SR-66) Sensitive 63.9 RW RW 61 5 Almeria Av. n/o Foothill Bl. (SR-66) Sensitive 67.1 RW RW 102 6 Citrus Av. n/o Foothill Bl. (SR-66) Sensitive 73.5 90 193 416 7 Citrus Av. s/o Foothill Bl. (SR-66) Sensitive 73.9 95 204 440 8 Foothill Bl. (SR-66) w/o Cherry Av. Sensitive 74.9 141 303 652 9 Foothill Bl. (SR-66) e/o Cherry Av. Non-Sensitive 74.9 141 304 654 10 Foothill Bl. (SR-66) w/o Hemlock Av. Sensitive 74.4 129 278 599 11 Foothill Bl. (SR-66) e/o Hemlock Av. Sensitive 74.6 133 287 617 12 Foothill Bl. (SR-66) e/o Beech Av. Sensitive 74.4 130 281 605 13 Foothill Bl. (SR-66) w/o Citrus Av. Non-Sensitive 74.5 132 284 612 14 Foothill Bl. (SR-66) e/o Citrus Av. Sensitive 74.4 130 281 606 1 Based on a review of existing aerial imagery. Noise sensitive uses limited to existing residential land uses. 2 The CNEL is calculated at the boundary of the right-of-way of the receiving adjacent land use. "RW" = Location of the respective noise contour falls within the right-of-way of the road. Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 30 TABLE 7-2: EXISTING WITH PROJECT CONTOURS ID Road Segment Receiving Land Use1 CNEL at Receiving Land Use (dBA)2 Distance to Contour from Centerline (Feet) 70 dBA CNEL 65 dBA CNEL 60 dBA CNEL 1 Cherry Av. n/o Foothill Bl. (SR-66) Non-Sensitive 74.7 135 291 627 2 Cherry Av. s/o Foothill Bl. (SR-66) Sensitive 74.5 132 284 611 3 Redwood Av. s/o Foothill Bl. (SR-66) Sensitive 66.4 RW RW 90 4 Hemlock Av. s/o Foothill Bl. (SR-66) Sensitive 63.9 RW RW 62 5 Almeria Av. n/o Foothill Bl. (SR-66) Sensitive 67.2 RW RW 102 6 Citrus Av. n/o Foothill Bl. (SR-66) Sensitive 73.6 90 194 418 7 Citrus Av. s/o Foothill Bl. (SR-66) Sensitive 74.0 96 206 444 8 Foothill Bl. (SR-66) w/o Cherry Av. Sensitive 74.9 141 303 654 9 Foothill Bl. (SR-66) e/o Cherry Av. Non-Sensitive 75.1 145 313 673 10 Foothill Bl. (SR-66) w/o Hemlock Av. Sensitive 74.6 133 287 619 11 Foothill Bl. (SR-66) e/o Hemlock Av. Sensitive 74.8 137 296 638 12 Foothill Bl. (SR-66) e/o Beech Av. Sensitive 74.5 132 284 613 13 Foothill Bl. (SR-66) w/o Citrus Av. Non-Sensitive 74.6 133 288 620 14 Foothill Bl. (SR-66) e/o Citrus Av. Sensitive 74.4 131 281 606 1 Based on a review of existing aerial imagery. Noise sensitive uses limited to existing residential land uses. 2 The CNEL is calculated at the boundary of the right-of-way of the receiving adjacent land use. "RW" = Location of the respective noise contour falls within the right-of-way of the road. Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 31 TABLE 7-3: OYC 2024 WITHOUT PROJECT CONTOURS ID Road Segment Receiving Land Use1 CNEL at Receiving Land Use (dBA)2 Distance to Contour from Centerline (Feet) 70 dBA CNEL 65 dBA CNEL 60 dBA CNEL 1 Cherry Av. n/o Foothill Bl. (SR-66) Non-Sensitive 75.2 146 315 679 2 Cherry Av. s/o Foothill Bl. (SR-66) Sensitive 74.9 140 302 651 3 Redwood Av. s/o Foothill Bl. (SR-66) Sensitive 66.7 RW RW 95 4 Hemlock Av. s/o Foothill Bl. (SR-66) Sensitive 64.3 RW RW 66 5 Almeria Av. n/o Foothill Bl. (SR-66) Sensitive 67.9 RW RW 114 6 Citrus Av. n/o Foothill Bl. (SR-66) Sensitive 73.9 94 203 438 7 Citrus Av. s/o Foothill Bl. (SR-66) Sensitive 74.2 100 215 462 8 Foothill Bl. (SR-66) w/o Cherry Av. Sensitive 75.6 155 334 720 9 Foothill Bl. (SR-66) e/o Cherry Av. Non-Sensitive 76.1 167 361 777 10 Foothill Bl. (SR-66) w/o Hemlock Av. Sensitive 74.8 139 299 644 11 Foothill Bl. (SR-66) e/o Hemlock Av. Sensitive 75.3 149 322 693 12 Foothill Bl. (SR-66) e/o Beech Av. Sensitive 75.2 148 318 686 13 Foothill Bl. (SR-66) w/o Citrus Av. Non-Sensitive 75.4 150 323 697 14 Foothill Bl. (SR-66) e/o Citrus Av. Sensitive 75.2 147 316 680 1 Based on a review of existing aerial imagery. Noise sensitive uses limited to existing residential land uses. 2 The CNEL is calculated at the boundary of the right-of-way of the receiving adjacent land use. "RW" = Location of the respective noise contour falls within the right-of-way of the road. Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 32 TABLE 7-4: OYC 2024 WITH PROJECT CONTOURS ID Road Segment Receiving Land Use1 CNEL at Receiving Land Use (dBA)2 Distance to Contour from Centerline (Feet) 70 dBA CNEL 65 dBA CNEL 60 dBA CNEL 1 Cherry Av. n/o Foothill Bl. (SR-66) Non-Sensitive 75.2 147 318 684 2 Cherry Av. s/o Foothill Bl. (SR-66) Sensitive 75.0 143 308 664 3 Redwood Av. s/o Foothill Bl. (SR-66) Sensitive 66.7 RW RW 95 4 Hemlock Av. s/o Foothill Bl. (SR-66) Sensitive 64.3 RW RW 66 5 Almeria Av. n/o Foothill Bl. (SR-66) Sensitive 67.9 RW RW 115 6 Citrus Av. n/o Foothill Bl. (SR-66) Sensitive 73.9 95 205 441 7 Citrus Av. s/o Foothill Bl. (SR-66) Sensitive 74.3 100 216 466 8 Foothill Bl. (SR-66) w/o Cherry Av. Sensitive 75.6 155 335 722 9 Foothill Bl. (SR-66) e/o Cherry Av. Non-Sensitive 76.2 171 369 795 10 Foothill Bl. (SR-66) w/o Hemlock Av. Sensitive 75.0 143 308 664 11 Foothill Bl. (SR-66) e/o Hemlock Av. Sensitive 75.5 153 331 712 12 Foothill Bl. (SR-66) e/o Beech Av. Sensitive 75.2 148 318 686 13 Foothill Bl. (SR-66) w/o Citrus Av. Non-Sensitive 75.4 150 323 697 14 Foothill Bl. (SR-66) e/o Citrus Av. Sensitive 75.2 147 316 680 1 Based on a review of existing aerial imagery. Noise sensitive uses limited to existing residential land uses. 2 The CNEL is calculated at the boundary of the right-of-way of the receiving adjacent land use. "RW" = Location of the respective noise contour falls within the right-of-way of the road. 7.2 EXISTING PROJECT TRAFFIC NOISE LEVEL INCREASES An analysis of existing traffic noise levels plus traffic noise generated by the proposed Project has been included in this report for informational purposes and to fully analyze all the existing traffic scenarios identified in the Traffic Study. However, the analysis of existing off-site traffic noise levels plus traffic noise generated by the proposed Project scenario will not actually occur since the Project would not be fully constructed and operational until 2024 conditions. Table 7-1 shows the Existing without Project conditions CNEL noise levels. The Existing without Project exterior noise levels range from 63.9 to 74.9 dBA CNEL, without accounting for any noise attenuation features such as noise barriers or topography. Table 7-2 shows the Existing with Project conditions ranging from 63.9 to 75.1 dBA CNEL. Table 7-5 shows that the Project off-site traffic noise level increases range from 0.0 to 0.2 dBA CNEL on the study area roadway segments. Based on the significance criteria for off-site traffic noise presented in Section 4.1, land uses adjacent to the study area roadway segments would experience less than significant noise level impacts due to unmitigated Project-related traffic noise levels. Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 33 TABLE 7-5: EXISTING WITH PROJECT TRAFFIC NOISE LEVEL INCREASES ID Road Segment Receiving Land Use1 CNEL at Receiving Land Use (dBA)1 Incremental Noise Level Increase Threshold2 No Project With Project Project Addition Limit Exceeded? 1 Cherry Av. n/o Foothill Bl. (SR-66) Non-Sensitive 74.6 74.7 0.1 1.5 No 2 Cherry Av. s/o Foothill Bl. (SR-66) Sensitive 74.4 74.5 0.1 1.5 No 3 Redwood Av. s/o Foothill Bl. (SR-66) Sensitive 66.4 66.4 0.0 1.5 No 4 Hemlock Av. s/o Foothill Bl. (SR-66) Sensitive 63.9 63.9 0.0 3.0 No 5 Almeria Av. n/o Foothill Bl. (SR-66) Sensitive 67.1 67.2 0.1 1.5 No 6 Citrus Av. n/o Foothill Bl. (SR-66) Sensitive 73.5 73.6 0.1 1.5 No 7 Citrus Av. s/o Foothill Bl. (SR-66) Sensitive 73.9 74.0 0.1 1.5 No 8 Foothill Bl. (SR-66) w/o Cherry Av. Sensitive 74.9 74.9 0.0 1.5 No 9 Foothill Bl. (SR-66) e/o Cherry Av. Non-Sensitive 74.9 75.1 0.2 1.5 No 10 Foothill Bl. (SR-66) w/o Hemlock Av. Sensitive 74.4 74.6 0.2 1.5 No 11 Foothill Bl. (SR-66) e/o Hemlock Av. Sensitive 74.6 74.8 0.2 1.5 No 12 Foothill Bl. (SR-66) e/o Beech Av. Sensitive 74.4 74.5 0.1 1.5 No 13 Foothill Bl. (SR-66) w/o Citrus Av. Non-Sensitive 74.5 74.6 0.1 1.5 No 14 Foothill Bl. (SR-66) e/o Citrus Av. Sensitive 74.4 74.4 0.0 1.5 No 1 Based on a review of existing aerial imagery. Noise sensitive uses limited to existing residential land uses. 2 The CNEL is calculated at the boundary of the right-of-way of each roadway and the property line of the receiving land use. 3 Does the Project create an incremental noise level increase exceeding the significance criteria (Table 4-1)? 7.3 2024 TRAFFIC NOISE LEVEL INCREASES Table 7-3 presents the OYC 2024 without Project conditions CNEL noise levels. The OYC 2024 without Project exterior noise levels range from 64.3 to 76.1 dBA CNEL, without accounting for any noise attenuation features such as noise barriers or topography. Table 7-4 shows that the OYC 2024 with Project conditions will range from 64.3 to 76.2 dBA CNEL. Table 7-6 shows that the Project off-site traffic noise level increases range from 0.0 to 0.2 dBA CNEL on the study area roadway segments. Based on the significance criteria for off-site traffic noise presented in Section 4.1, land uses adjacent to the study area roadway segments would experience less than significant noise level impacts due to unmitigated Project-related traffic noise levels. Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 34 TABLE 7-6: OYC 2024 WITH PROJECT TRAFFIC NOISE LEVEL INCREASES ID Road Segment Receiving Land Use1 CNEL at Receiving Land Use (dBA)1 Incremental Noise Level Increase Threshold2 No Project With Project Project Addition Limit Exceeded? 1 Cherry Av. n/o Foothill Bl. (SR-66) Non-Sensitive 75.2 75.2 0.0 1.5 No 2 Cherry Av. s/o Foothill Bl. (SR-66) Sensitive 74.9 75.0 0.1 1.5 No 3 Redwood Av. s/o Foothill Bl. (SR-66) Sensitive 66.7 66.7 0.0 1.5 No 4 Hemlock Av. s/o Foothill Bl. (SR-66) Sensitive 64.3 64.3 0.0 3.0 No 5 Almeria Av. n/o Foothill Bl. (SR-66) Sensitive 67.9 67.9 0.0 1.5 No 6 Citrus Av. n/o Foothill Bl. (SR-66) Sensitive 73.9 73.9 0.0 1.5 No 7 Citrus Av. s/o Foothill Bl. (SR-66) Sensitive 74.2 74.3 0.1 1.5 No 8 Foothill Bl. (SR-66) w/o Cherry Av. Sensitive 75.6 75.6 0.0 1.5 No 9 Foothill Bl. (SR-66) e/o Cherry Av. Non-Sensitive 76.1 76.2 0.1 1.5 No 10 Foothill Bl. (SR-66) w/o Hemlock Av. Sensitive 74.8 75.0 0.2 1.5 No 11 Foothill Bl. (SR-66) e/o Hemlock Av. Sensitive 75.3 75.5 0.2 1.5 No 12 Foothill Bl. (SR-66) e/o Beech Av. Sensitive 75.2 75.2 0.0 1.5 No 13 Foothill Bl. (SR-66) w/o Citrus Av. Non-Sensitive 75.4 75.4 0.0 1.5 No 14 Foothill Bl. (SR-66) e/o Citrus Av. Sensitive 75.2 75.2 0.0 1.5 No 1 Based on a review of existing aerial imagery. Noise sensitive uses limited to existing residential land uses. 2 The CNEL is calculated at the boundary of the right-of-way of each roadway and the property line of the receiving land use. 3 Does the Project create an incremental noise level increase exceeding the significance criteria (Table 4-1)? Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 35 8 RECEIVER LOCATIONS To assess the potential for long-term operational and short-term construction noise impacts, the following sensitive receiver locations, as shown on Exhibit 8-A, were identified as representative locations for analysis. Sensitive receivers are generally defined as locations where people reside or where the presence of unwanted sound could otherwise adversely affect the use of the land. Noise-sensitive land uses are generally considered to include schools, hospitals, single-family dwellings, mobile home parks, churches, libraries, and recreation areas. Moderately noise- sensitive land uses typically include multi-family dwellings, hotels, motels, dormitories, out- patient clinics, cemeteries, golf courses, country clubs, athletic/tennis clubs, and equestrian clubs. Land uses that are considered relatively insensitive to noise include business, commercial, and professional developments. Land uses that are typically not affected by noise include: industrial, manufacturing, utilities, agriculture, undeveloped land, parking lots, warehousing, liquid and solid waste facilities, salvage yards, and transit terminals. To describe the potential off-site Project noise levels, six receiver locations in the vicinity of the Project site were identified. The selection of receiver locations is based on FHWA guidelines and is consistent with additional guidance provided by Caltrans and the FTA, as previously described in Section 5.2. Other sensitive land uses in the Project study area that are located at greater distances than those identified in this noise study will experience lower noise levels than those presented in this report due to the additional attenuation from distance and the shielding of intervening structures. Distance is measured in a straight line from the project boundary to each receiver location. R1: Location R1 represents existing noise sensitive residence at 15247 Montanez Street, approximately 88 feet northwest of the Project site. Receiver R1 is placed in the private outdoor living areas (backyard) facing the Project site. A 24-hour noise measurement was taken near this location, L1, to describe the existing ambient noise environment. R2: Location R2 represents the existing noise sensitive park southwest of Parsley Leaf Place, approximately 130 feet north of the Project site. Receiver R2 is placed in the private outdoor living areas facing the Project site. A 24-hour noise measurement was taken near this location, L2, to describe the existing ambient noise environment. R3: Location R3 represents the existing noise sensitive residence at 15459 Vanilla Bean Lane, approximately 772 feet east of the Project site. Receiver R3 is placed in the private outdoor living areas (backyard) facing the Project site. A 24-hour noise measurement was taken near this location, L3, to describe the existing ambient noise environment. R4: Location R4 represents the existing noise sensitive residence at 15357 Foothill Boulevard, approximately 852 feet southeast of the Project site. Since there are no private outdoor living areas (backyard) facing the Project site, receiver R4 is placed at the building’s façade. A 24-hour noise measurement was taken near this location, L4, to describe the existing ambient noise environment. R5: Location R5 represents the existing noise sensitive Sunset Motel at 15243 Foothill Boulevard, approximately 737 feet south of the Project site. Since there are no private outdoor living areas (backyard) facing the Project site, receiver R5 is placed at the Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 36 building’s façade. A 24-hour noise measurement was taken near this location, L5, to describe the existing ambient noise environment. R6: Location R6 represents the existing noise sensitive Forty Winks Motel at 15210 Foothill Boulevard, approximately 332 feet southwest of the Project site Receiver R6 is placed in the private outdoor living areas facing the Project site. A 24-hour noise measurement was taken near this location, L6, to describe the existing ambient noise environment. EXHIBIT 8-A: RECEIVER LOCATIONS Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 37 9 OPERATIONAL NOISE ANALYSIS This section analyzes the potential stationary-source operational noise impacts at the nearby receiver locations, identified in Section 8, resulting from the operation of the proposed Beech Logistics Center Project. Exhibit 9-A identifies the noise source locations used to assess the operational noise levels. 9.1 OPERATIONAL NOISE SOURCES This operational noise analysis is intended to describe noise level impacts associated with the expected typical of daytime and nighttime activities at the Project site. To present the potential worst-case noise conditions, this analysis assumes the Project would be operational 24 hours per day, seven days per week. Consistent with similar warehouse and industrial uses, the Project business operations would primarily be conducted within the enclosed buildings, except for traffic movement, parking, as well as loading and unloading of trucks at designated loading bays. The on-site Project-related noise sources are expected to include: loading dock activity, roof-top air conditioning units, trash enclosure activity, parking lot vehicle movements, and truck movements. 9.2 REFERENCE NOISE LEVELS To estimate the Project operational noise impacts, reference noise level measurements were collected from similar types of activities to represent the noise levels expected with the development of the proposed Project. This section provides a detailed description of the reference noise level measurements shown on Table 9-1 used to estimate the Project operational noise impacts. It is important to note that the following projected noise levels assume the worst- case noise environment with the loading dock activity, roof-top air conditioning units, trash enclosure activity, parking lot vehicle movements, and truck movements all operating at the same time. These sources of noise activity will likely vary throughout the day. 9.2.1 MEASUREMENT PROCEDURES The reference noise level measurements presented in this section were collected using a Larson Davis LxT Type 1 precisions sound level meter (serial number 01146). The LxT sound level meter was calibrated using a Larson-Davis calibrator, Model CAL 200, was programmed in "slow" mode to record noise levels in "A" weighted form and was located at approximately five feet above the ground elevation for each measurement. The sound level meters and microphones were equipped with a windscreen during all measurements. All noise level measurement equipment satisfies the American National Standards Institute (ANSI) standard specifications for sound level meters ANSI S1.4-2014/IEC 61672-1:2013. (18) Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 38 EXHIBIT 9-A: OPERATIONAL NOISE SOURCE LOCATIONS Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 39 TABLE 9-1: REFERENCE NOISE LEVEL MEASUREMENTS Noise Source1 Noise Source Height (Feet) Min./ Hour2 Reference Noise Level (dBA Leq) @ 50 Feet Sound Power Level (dBA)3 Day Night Loading Dock Activity 8' 60 60 65.7 111.5 Roof-Top Air Conditioning Units 5' 39 28 57.2 88.9 Trash Enclosure Activity 5' 60 60 57.3 89.0 Parking Lot Vehicle Movements 5' 60 60 52.6 81.1 Truck Movements 8' 60 60 59.8 93.2 1 As measured by Urban Crossroads, Inc. 2 Anticipated duration (minutes within the hour) of noise activity during typical hourly conditions expected at the Project site. "Daytime" = 7:00 a.m. - 10:00 p.m.; "Nighttime" = 10:00 p.m. - 7:00 a.m. 3 Sound power level represents the total amount of acoustical energy (noise level) produced by a sound source independent of distance or surroundings. Sound power levels calculated using the CadnaA noise model at the reference distance to the noise source. 9.2.2 LOADING DOCK ACTIVITY The reference loading dock activities are intended to describe the typical outdoor operational noise activities associated with the Project. This includes truck idling, reefer activity (refrigerator truck/cold storage), deliveries, backup alarms, trailer docking including a combination of tractor trailer semi-trucks, two-axle delivery trucks, and background operation activities. The reference noise level measurement was taken in the center of the loading dock activity area and represents multiple concurrent noise sources resulting in a combined noise level of 65.7 dBA Leq at a uniform distance of 50 feet. Specifically, the reference noise level measurement represents one truck located approximately 30 feet from the noise level meter with another truck passing by to park roughly 20 feet away, both with their engines idling. Throughout the reference noise level measurement, a separate docked and running reefer truck was located approximately 50 feet east of the measurement location. Additional background noise sources included truck pass-by noise, truck drivers talking to each other next to docked trucks, and air brake release noise when trucks parked. 9.2.3 ROOF-TOP AIR CONDITIONING UNITS The noise level measurements describe a single mechanical roof-top air conditioning unit. The reference noise level represents a Lennox SCA120 series 10-ton model packaged air conditioning unit. At the uniform reference distance of 50 feet, the reference noise levels are 57.2 dBA Leq. Based on the typical operating conditions observed over a four-day measurement period, the roof-top air conditioning units are estimated to operate for and average 39 minutes per hour during the daytime hours, and 28 minutes per hour during the nighttime hours. These operating conditions reflect peak summer cooling requirements with measured temperatures approaching 96 degrees Fahrenheit (°F) with average daytime temperatures of 82°F. For this noise analysis, the air conditioning units are expected to be located on the roof of the Project buildings. Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 40 9.2.5 TRASH ENCLOSURE ACTIVITY To describe the noise levels associated with a trash enclosure activity, Urban Crossroads collected a reference noise level measurement at an existing trash enclosure containing two dumpster bins. The trash enclosure noise levels describe metal gates opening and closing, metal scraping against concrete floor sounds, dumpster movement on metal wheels, and trash dropping into the metal dumpster. The reference noise levels describe trash enclosure noise activities when trash is dropped into an empty metal dumpster, as would occur at the Project Site. The measured reference noise level at the uniform 50-foot reference distance is 57.3 dBA Leq for the trash enclosure activity. The reference noise level describes the expected noise source activities associated with the trash enclosures for the Project’s proposed building. 9.2.6 PARKING LOT VEHICLE MOVEMENTS To describe the on-site parking lot activity, a long-term 29-hour reference noise level measurement was collected in the center of activity within the staff parking lot of an Amazon warehouse distribution center. At 50 feet from the center of activity, the parking lot produced a reference noise level of 52.6 dBA Leq. Parking activities are expected to take place during the full hour (60 minutes) throughout the daytime and evening hours. The parking lot noise levels are mainly due cars pulling in and out of parking spaces in combination with car doors opening and closing. 9.2.7 TRUCK MOVEMENTS The truck movements reference noise level measurement was collected over a period of 1 hour and 28 minutes and represents multiple heavy trucks entering and exiting the outdoor loading dock area producing a reference noise level of 59.8 dBA Leq at 50 feet. The noise sources included at this measurement location account for trucks entering and existing the Project driveways and maneuvering in and out of the outdoor loading dock activity area. 9.3 CADNAA NOISE PREDICTION MODEL To fully describe the exterior operational noise levels from the Project, Urban Crossroads, Inc. developed a noise prediction model using the CadnaA (Computer Aided Noise Abatement) computer program. CadnaA can analyze multiple types of noise sources using the spatially accurate Project site plan, georeferenced Nearmap aerial imagery, topography, buildings, and barriers in its calculations to predict outdoor noise levels. Using the ISO 9613-2 protocol, CadnaA will calculate the distance from each noise source to the noise receiver locations, using the ground absorption, distance, and barrier/building attenuation inputs to provide a summary of noise level at each receiver and the partial noise level contributions by noise source. Consistent with the ISO 9613-2 protocol, the CadnaA noise prediction model relies on the reference sound power level (Lw) to describe individual noise sources. While sound pressure levels (e.g., Leq) quantify in decibels the intensity of given sound sources at a reference distance, sound power levels (Lw) are connected to the sound source and are independent of distance. Sound pressure levels vary substantially with distance from the Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 41 source and diminish because of intervening obstacles and barriers, air absorption, wind, and other factors. Sound power is the acoustical energy emitted by the sound source and is an absolute value that is not affected by the environment. The operational noise level calculations provided in this noise study account for the distance attenuation provided due to geometric spreading, when sound from a localized stationary source (i.e., a point source) propagates uniformly outward in a spherical pattern. A default ground attenuation factor of 0.5 was used in the CadnaA noise analysis to account for mixed ground representing a combination of hard and soft surfaces. Appendix 9.1 includes the detailed noise model inputs used to estimate the Project operational noise levels presented in this section. 9.4 PROJECT OPERATIONAL NOISE LEVELS Using the reference noise levels to represent the proposed Project operations that include loading dock activity, roof-top air conditioning units, trash enclosure activity, parking lot vehicle movements, and truck movements, Urban Crossroads, Inc. calculated the operational source noise levels that are expected to be generated at the Project site and the Project-related noise level increases that would be experienced at each of the sensitive receiver locations. Table 9-2 shows the Project operational noise levels during the daytime hours of 7:00 a.m. to 10:00 p.m. The daytime hourly noise levels at the off-site receiver locations are expected to range from 44.0 to 53.0 dBA Leq. TABLE 9-2: DAYTIME PROJECT OPERATIONAL NOISE LEVELS Noise Source1 Operational Noise Levels by Receiver Location (dBA Leq) R1 R2 R3 R4 R5 R6 Loading Dock Activity 48.8 52.3 45.2 44.0 44.7 41.2 Roof-Top Air Conditioning Units 21.8 33.3 27.7 28.3 29.1 33.1 Trash Enclosure Activity 24.9 26.4 19.8 15.3 23.4 8.7 Parking Lot Vehicle Movements 37.9 27.3 29.0 29.1 32.0 37.7 Truck Movements 25.7 44.6 35.0 32.6 33.7 36.2 Total (All Noise Sources) 49.2 53.0 45.8 44.5 45.4 44.0 1 See Exhibit 9-A for the noise source locations. CadnaA noise model calculations are included in Appendix 9.1. Table 9-3 shows the Project operational noise levels during the nighttime hours of 10:00 p.m. to 7:00 a.m. The nighttime hourly noise levels at the off-site receiver locations are expected to range from 43.9 to 53.0 dBA Leq. The differences between the daytime and nighttime noise levels are largely related to the estimated duration of noise activity as outlined in Table 9-1 and Appendix 9.1. Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 42 TABLE 9-3: NIGHTTIME PROJECT OPERATIONAL NOISE LEVELS Noise Source1 Operational Noise Levels by Receiver Location (dBA Leq) R1 R2 R3 R4 R5 R6 Loading Dock Activity 48.8 52.3 45.2 44.0 44.7 41.2 Roof-Top Air Conditioning Units 19.4 30.9 25.3 25.9 26.7 30.7 Trash Enclosure Activity 24.9 26.4 19.8 15.3 23.4 8.7 Parking Lot Vehicle Movements 37.9 27.3 29.0 29.1 32.0 37.7 Truck Movements 25.7 44.6 35.0 32.6 33.7 36.2 Total (All Noise Sources) 49.2 53.0 45.7 44.5 45.3 43.9 1 See Exhibit 9-A for the noise source locations. CadnaA noise model calculations are included in Appendix 9.1. 9.5 PROJECT OPERATIONAL NOISE LEVEL COMPLIANCE To demonstrate compliance with local noise regulations, the Project-only operational noise levels are evaluated against exterior noise level thresholds based on the City of Fontana exterior noise level standards at nearby noise-sensitive receiver locations. Table 9-4 shows the operational noise levels associated with Beech Logistics Center Project will satisfy the City of Fontana 70 dBA Leq daytime and 65 dBA Leq nighttime exterior noise level standards at the nearest receiver locations. Therefore, the operational noise impacts are considered less than significant at the nearby noise-sensitive receiver locations. TABLE 9-4: OPERATIONAL NOISE LEVEL COMPLIANCE Receiver Location1 Project Operational Noise Levels (dBA Leq)2 Noise Level Standards (dBA Leq)3 Noise Level Standards Exceeded?4 Daytime Nighttime Daytime Nighttime Daytime Nighttime R1 49.2 49.2 70 65 No No R2 53.0 53.0 70 65 No No R3 45.8 45.7 70 65 No No R4 44.5 44.5 70 65 No No R5 45.4 45.3 70 65 No No R6 44.0 43.9 70 65 No No 1 See Exhibit 8-A for the receiver locations. 2 Proposed Project operational noise levels as shown on Tables 9-2 and 9-3. 3 Exterior noise level standards, as shown on Table 4-1. 4 Do the estimated Project operational noise source activities exceed the noise level standards? "Daytime" = 7:00 a.m. - 10:00 p.m.; "Nighttime" = 10:00 p.m. - 7:00 a.m. Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 43 9.6 PROJECT OPERATIONAL NOISE LEVEL INCREASES To describe the Project operational noise level increases, the Project operational noise levels are combined with the existing ambient noise levels measurements for the nearby receiver locations potentially impacted by Project operational noise sources. Since the units used to measure noise, decibels (dB), are logarithmic units, the Project-operational and existing ambient noise levels cannot be combined using standard arithmetic equations. (2) Instead, they must be logarithmically added using the following base equation: SPLTotal = 10log10[10SPL1/10 + 10SPL2/10 + … 10SPLn/10] Where “SPL1,” “SPL2,” etc. are equal to the sound pressure levels being combined, or in this case, the Project-operational and existing ambient noise levels. The difference between the combined Project and ambient noise levels describes the Project noise level increases to the existing ambient noise environment. As indicated on Table 9-5, the Project will generate a daytime noise level increase ranging from 0.0 to 3.8 dBA Leq operational noise level increase at the nearest receiver locations. Table 9-6 shows that the Project will generate a nighttime operational noise level increase ranging from 0.0 to 4.0 dBA Leq at the nearest receiver locations. TABLE 9-5: DAYTIME PROJECT OPERATIONAL NOISE LEVEL INCREASES Receiver Location1 Total Project Operational Noise Level2 Measurement Location3 Reference Ambient Noise Levels4 Combined Project and Ambient5 Project Increase6 Increase Criteria7 Increase Criteria Exceeded? R1 49.2 L1 51.2 53.3 2.1 5.0 No R2 53.0 L2 51.6 55.4 3.8 5.0 No R3 45.8 L3 65.0 65.1 0.1 1.5 No R4 44.5 L4 69.9 69.9 0.0 1.5 No R5 45.4 L5 71.5 71.5 0.0 1.5 No R6 44.0 L6 54.0 54.4 0.4 5.0 No 1 See Exhibit 8-A for the receiver locations. 2 Total Project daytime operational noise levels as shown on Table 9-2. 3 Reference noise level measurement locations as shown on Exhibit 5-A. 4 Observed daytime ambient noise levels as shown on Table 5-1. 5 Represents the combined ambient conditions plus the Project activities. 6 The noise level increase expected with the addition of the proposed Project activities. 7 Significance increase criteria as shown on Table 4-1. Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 44 TABLE 9-6: NIGHTTIME OPERATIONAL NOISE LEVEL INCREASES Receiver Location1 Total Project Operational Noise Level2 Measurement Location3 Reference Ambient Noise Levels4 Combined Project and Ambient5 Project Increase6 Increase Criteria7 Increase Criteria Exceeded? R1 49.2 L1 50.7 53.0 2.3 5.0 No R2 53.0 L2 51.3 55.3 4.0 5.0 No R3 45.7 L3 61.0 61.1 0.1 5.0 No R4 44.5 L4 65.9 65.9 0.0 1.5 No R5 45.3 L5 67.3 67.3 0.0 1.5 No R6 43.9 L6 54.5 54.9 0.4 5.0 No 1 See Exhibit 8-A for the receiver locations. 2 Total Project nighttime operational noise levels as shown on Table 9-3. 3 Reference noise level measurement locations as shown on Exhibit 5-A. 4 Observed nighttime ambient noise levels as shown on Table 5-1. 5 Represents the combined ambient conditions plus the Project activities. 6 The noise level increase expected with the addition of the proposed Project activities. 7 Significance increase criteria as shown on Table 4-1. The Project-related operational noise level increases will satisfy the operational noise level increase significance criteria presented on Table 4-1. Therefore, the incremental Project operational noise level increase is considered less than significant at all receiver locations. Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 45 10 CONSTRUCTION ANALYSIS This section analyzes potential impacts resulting from the short-term construction activities associated with the development of the Project. Exhibit 10-A shows the construction activity boundaries in relation to the nearest sensitive receiver locations previously described in Section 8. The City of Fontana Municipal Code Section 18-63[7], states that project construction noise levels are considered exempt between 7:00 a.m. and 6:00 p.m. on weekdays and between the hours of 8:00 a.m. to 5:00 p.m. on Saturdays. In addition, neither the General Plan nor the Municipal Code establish numeric maximum acceptable construction source noise levels at potentially affected receivers for CEQA analysis purposes. Therefore, a numerical construction threshold based on Federal Transit Administration (FTA) Transit Noise and Vibration Impact Assessment Manual is used for analysis of daytime construction impacts. The FTA considers a daytime exterior construction noise level of 80 dBA Leq as a reasonable threshold for noise sensitive residential land use with a nighttime exterior construction noise level of 70 dBA Leq (8 p. 179). 10.1 CONSTRUCTION NOISE LEVELS The FTA Transit Noise and Vibration Impact Assessment Manual recognizes that construction projects are accomplished in several different stages and outlines the procedures for assessing noise impacts during construction. Each stage has a specific equipment mix, depending on the work to be completed during that stage. As a result of the equipment mix, each stage has its own noise characteristics; some stages have higher continuous noise levels than others, and some have higher impact noise levels than others. The Project construction activities are expected to occur in the following stages: • Site Preparation • Grading • Building Construction • Paving • Architectural Coating 10.2 CONSTRUCTION REFERENCE NOISE LEVELS To describe construction noise activities, this construction noise analysis was prepared using reference construction equipment noise levels from the Federal Highway Administration (FHWA) published the Roadway Construction Noise Model (RCNM), which includes a national database of construction equipment reference noise emission levels. (23) The RCNM equipment database, provides a comprehensive list of the noise generating characteristics for specific types of construction equipment. In addition, the database provides an acoustical usage factor to estimate the fraction of time each piece of construction equipment is operating at full power (i.e., its loudest condition) during a construction operation. Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 46 EXHIBIT 10-A: CONSTRUCTION NOISE SOURCE AND RECEIVER LOCATIONS Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 47 10.3 CONSTRUCTION NOISE ANALYSIS Using the reference construction equipment noise levels and the CadnaA noise prediction model, calculations of the Project construction noise level impacts at the nearby sensitive receiver locations were completed. Consistent with FTA guidance for general construction noise assessment, Table 10-1 presents the combined noise levels for the loudest construction equipment, assuming they operate at the same time. As shown on Table 10-2, the construction noise levels are expected to range from 50.1 to 65.5 dBA Leq at the nearby receiver locations. Appendix 10.1 includes the detailed CadnaA construction noise model inputs. TABLE 10-1: CONSTRUCTION REFERENCE NOISE LEVELS Construction Stage Reference Construction Activity Reference Noise Level @ 50 Feet (dBA Leq)1 Combined Noise Level (dBA Leq)2 Combined Sound Power Level (PWL)3 Demolition Demolition Equipment 82 83 115 Backhoes 74 Hauling Trucks 72 Site Preparation Crawler Tractors 78 80 112 Hauling Trucks 72 Rubber Tired Dozers 75 Grading Graders 81 83 115 Excavators 77 Compactors 76 Building Construction Cranes 73 81 113 Tractors 80 Welders 70 Paving Pavers 74 83 115 Paving Equipment 82 Rollers 73 Architectural Coating Cranes 73 77 109 Air Compressors 74 Generator Sets 70 1 FHWA Roadway Construction Noise Model (RCNM). 2 Represents the combined noise level for all equipment assuming they operate at the same time consistent with FTA Transit Noise and Vibration Impact Assessment guidance. 3 Sound power level represents the total amount of acoustical energy (noise level) produced by a sound source independent of distance or surroundings. Sound power levels calibrated using the CadnaA noise model at the reference distance to the noise source. Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 48 TABLE 10-2: CONSTRUCTION EQUIPMENT NOISE LEVEL SUMMARY Receiver Location1 Construction Noise Levels (dBA Leq) Site Preparation Grading Building Construction Paving Architectural Coating Highest Levels2 R1 59.2 62.2 60.2 62.2 56.2 62.2 R2 62.5 65.5 63.5 65.5 59.5 65.5 R3 54.4 57.4 55.4 57.4 51.4 57.4 R4 53.1 56.1 54.1 56.1 50.1 56.1 R5 54.9 57.9 55.9 57.9 51.9 57.9 R6 59.0 62.0 60.0 62.0 56.0 62.0 1 Noise receiver locations are shown on Exhibit 10-A. 2 Construction noise level calculations based on distance from the construction activity, which is measured from the Project site boundary to the nearest receiver locations. CadnaA construction noise model inputs are included in Appendix 10.1. 10.4 CONSTRUCTION NOISE LEVEL COMPLIANCE To evaluate whether the Project will generate potentially significant short-term noise levels at nearest receiver locations, a construction-related daytime noise level threshold of 80 dBA Leq is used as a reasonable threshold to assess the daytime construction noise level impacts. The construction noise analysis shows that the nearest receiver locations will not exceed the reasonable daytime 80 dBA Leq significance threshold during Project construction activities as shown on Table 10-3. Therefore, the noise impacts due to Project construction noise are considered less than significant at all receiver locations. Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 49 TABLE 10-3: TYPICAL CONSTRUCTION NOISE LEVEL COMPLIANCE Receiver Location1 Construction Noise Levels (dBA Leq) Highest Construction Noise Levels2 Threshold3 Threshold Exceeded?4 R1 62.2 80 No R2 65.5 80 No R3 57.4 80 No R4 56.1 80 No R5 57.9 80 No R6 62.0 80 No 1 Construction noise source and receiver locations are shown on Exhibit 10-A. 2 Highest construction noise level calculations based on distance from the construction noise source activity to the nearest receiver locations as shown on Table 10-2. 3 Construction noise level thresholds as shown on Table 4-1. 4 Do the estimated Project construction noise levels exceed the construction noise level threshold? 10.5 NIGHTTIME CONCRETE POUR NOISE ANALYSIS It is our understanding that nighttime concrete pouring activities will occur as a part of Project building construction activities. Nighttime concrete pouring activities are often used to support reduced concrete mixer truck transit times and lower air temperatures than during the daytime hours and are generally limited to the actual building pad area. Since the nighttime concrete pours will take place outside the permitted City of Fontana Municipal Code, Section 18-63(b)(7) hours of 7:00 a.m. and 6:00 p.m. on weekdays and between the hours of 8:00 a.m. and 5:00 p.m. on Saturdays the Project Applicant will be required to obtain authorization for nighttime work from the City of Fontana. Any nighttime construction noise activities are evaluated against the FTA nighttime exterior construction noise level threshold of 70 dBA Leq for noise sensitive residential land use (8 p. 179). 10.5.1 NIGHTTIME CONCRETE POUR REFERENCE NOISE LEVEL MEASUREMENTS To estimate the noise levels due to nighttime concrete pour activities, sample reference noise level measurements were taken during a nighttime concrete pour at a construction site. Urban Crossroads, Inc. collected short-term nighttime concrete pour reference noise level measurements during the noise-sensitive nighttime hours between 1:00 a.m. to 2:00 a.m. at 27334 San Bernardino Avenue in the City of Redlands. The reference noise levels describe the expected concrete pour noise sources that may include concrete mixer truck movements and pouring activities, concrete paving equipment, rear mounted concrete mixer truck backup alarms, engine idling, air brakes, generators, and workers communicating/whistling. To describe the nighttime concrete pour noise levels associated with the construction of the Beech Logistics Center, this analysis relies on reference sound pressure level of 67.7 dBA Leq at 50 feet representing a sound power level of 100.3 dBA Lw. While the Project noise levels will depend on the actual duration of activities and specific equipment fleet in use at the time of construction, Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 50 the reference sound power level of 100.3 dBA Lw is used to describe the expected Project nighttime concrete pour noise activities. 10.5.2 NIGHTTIME CONCRETE POUR NOISE LEVEL COMPLIANCE As shown on Table 10-4, the noise levels associated with the nighttime concrete pour activities (paving) are estimated to range from 40.8 to 48.8 dBA Leq and will not exceed FTA nighttime exterior construction noise level threshold of 70 dBA Leq for noise sensitive residential land use (8 p. 179). Based on the results of this analysis, all nearest noise receiver locations will experience less than significant impacts due to the Project related nighttime concrete pour activities. Appendix 10.2 includes the CadnaA nighttime concrete pour noise model inputs. TABLE 10-4: NIGHTTIME CONCRETE POUR NOISE LEVEL COMPLIANCE Receiver Location1 Concrete Pour Construction Noise Levels (dBA Leq) Exterior Noise Levels2 Nighttime Threshold3 Threshold Exceeded?4 R1 47.0 70 No R2 48.8 70 No R3 42.0 70 No R4 40.8 70 No R5 42.9 70 No R6 47.1 70 No 1 Construction noise source and receiver locations are shown on Exhibit 10-A. 2 Nighttime Concrete Pour noise model inputs are included in Appendix 10.2. 3 Construction noise level thresholds as shown on Table 4-1. 4 Do the estimated Project construction noise levels exceed the nighttime construction noise level threshold? Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 51 EXHIBIT 10-B: NIGHTTIME CONCRETE POUR NOISE SOURCE AND RECEIVER LOCATIONS Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 52 10.6 CONSTRUCTION VIBRATION ANALYSIS Construction activity can result in varying degrees of ground vibration, depending on the equipment and methods employed. Operation of construction equipment causes ground vibrations that spread through the ground and diminish in strength with distance. Ground vibration levels associated with various types of construction equipment are summarized on Table 10-5. Based on the representative vibration levels presented for various construction equipment types, it is possible to estimate the potential for human response (annoyance) and building damage using the following vibration assessment methods defined by the FTA. To describe the vibration impacts the FTA provides the following equation: PPVequip = PPVref x (25/D)1.5 TABLE 10-5: VIBRATION SOURCE LEVELS FOR CONSTRUCTION EQUIPMENT Equipment PPV (in/sec) at 25 feet Small bulldozer 0.003 Jackhammer 0.035 Loaded Trucks 0.076 Large bulldozer 0.089 Vibratory Roller 0.210 Federal Transit Administration, Transit Noise and Vibration Impact Assessment Manual Table 10-6 presents the expected Project related vibration levels at the nearby receiver locations. At distances ranging from 88 to 852 feet from Project construction activities, construction vibration velocity levels are estimated to range from 0.001 to 0.032 in/sec PPV. Based on maximum acceptable continuous vibration threshold of 0.3 PPV (in/sec), the typical Project construction vibration levels will fall below the building damage thresholds at all the noise sensitive receiver locations. Therefore, the Project-related vibration impacts are considered less than significant during typical construction activities at the Project site. Moreover, the vibration levels reported at the sensitive receiver locations are unlikely to be sustained during the entire construction period but will occur rather only during the times that heavy construction equipment is operating adjacent to the Project site perimeter. Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 53 TABLE 10-6: PROJECT CONSTRUCTION VIBRATION LEVELS Receiver1 Distance to Const. Activity (Feet)2 Typical Construction Vibration Levels PPV (in/sec)3 Thresholds PPV (in/sec)4 Thresholds Exceeded?5 Small bulldozer Jackhammer Loaded Trucks Large bulldozer Vibratory Roller Highest Vibration Level R1 88' 0.000 0.005 0.012 0.013 0.032 0.032 0.3 No R2 130' 0.000 0.003 0.006 0.008 0.018 0.018 0.3 No R3 772' 0.000 0.000 0.000 0.001 0.001 0.001 0.3 No R4 852' 0.000 0.000 0.000 0.000 0.001 0.001 0.3 No R5 737' 0.000 0.000 0.000 0.001 0.001 0.001 0.3 No R6 332' 0.000 0.001 0.002 0.002 0.004 0.004 0.3 No 1 Receiver locations are shown on Exhibit 10-A. 2 Distance from receiver location to Project construction boundary (Project site boundary). 3 Based on the Vibration Source Levels of Construction Equipment (Table 10-4). 4 Caltrans Transportation and Construction Vibration Guidance Manual, April 2020, Table 19, p. 38. 5 Does the peak vibration exceed the acceptable vibration thresholds? "PPV" = Peak Particle Velocity Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 54 This page intentionally left blank Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 55 11 REFERENCES 1. State of California. California Environmental Quality Act, Environmental Checklist Form Appendix G. 2021. 2. California Department of Transportation Environmental Program. Technical Noise Supplement - A Technical Supplement to the Traffic Noise Analysis Protocol. Sacramento, CA : s.n., September 2013. 3. Environmental Protection Agency Office of Noise Abatement and Control. Information on Levels of Environmental Noise Requisite to Protect Public Health and Welfare with an Adequate Margin of Safety. March 1974. EPA/ONAC 550/9/74-004. 4. U.S. Department of Transportation, Federal Highway Administration, Office of Environment and Planning, Noise and Air Quality Branch. Highway Traffic Noise Analysis and Abatement Policy and Guidance. December 2011. 5. U.S. Department of Transportation Federal Highway Administration. Highway Noise Barrier Design Handbook. 2001. 6. U.S. Department of Transportation, Federal Highway Administration. Highway Traffic Noise in the United States, Problem and Response. April 2000. p. 3. 7. U.S. Environmental Protection Agency Office of Noise Abatement and Control. Noise Effects Handbook-A Desk Reference to Health and Welfare Effects of Noise. October 1979 (revised July 1981). EPA 550/9/82/106. 8. U.S. Department of Transportation, Federal Transit Administration. Transit Noise and Vibration Impact Assessment Manual. September 2018. 9. Office of Planning and Research. State of California General Plan Guidlines. October 2019. 10. City of Fontana. General Plan Noise Element. November 2018. 11. —. Zoning and Development Code, Section 30, Article V - Residential Zoning Districts, Division 6 - Performance Standards. 12. —. Municipal Code, Chapter 18, Article II - Noise. 13. California Department of Transportation. Transportation and Construction Vibration Guidance Manual. April 2020. 14. California Court of Appeal. Gray v. County of Madera, F053661. 167 Cal.App.4th 1099; - Cal.Rptr.3d, October 2008. 15. Federal Interagency Committee on Noise. Federal Agency Review of Selected Airport Noise Analysis Issues. August 1992. 16. California Department of Transportation. Technical Noise Supplement. November 2009. 17. American National Standards Institute (ANSI). Specification for Sound Level Meters ANSI S1.4- 2014/IEC 61672-1:2013. 18. U.S. Department of Transportation, Federal Highway Administration. FHWA Highway Traffic Noise Prediction Model. December 1978. FHWA-RD-77-108. 19. California Department of Transportation Environmental Program, Office of Environmental Engineering. Use of California Vehicle Noise Reference Energy Mean Emission Levels (Calveno REMELs) in FHWA Highway Traffic Noise Prediction. September 1995. TAN 95-03. Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 56 20. California Department of Transportation. Traffic Noise Attenuation as a Function of Ground and Vegetation Final Report. June 1995. FHWA/CA/TL-95/23. 21. Urban Crossroads, Inc. Beech Logistics Center Traffic Study. 22. U.S. Department of Transportation, Federal Highway Administration, Office of Environment and Planning. FHWA Roadway Construction Noise Model. January, 2006. Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 57 12 CERTIFICATIONS The contents of this noise study report represent an accurate depiction of the noise environment and impacts associated with the proposed Beech Logistics Center Project. The information contained in this noise study report is based on the best available data at the time of preparation. If you have any questions, please contact me directly at (949) 584-3148. Bill Lawson, P.E., INCE Principal URBAN CROSSROADS, INC. 260 E. Baker Street, Suite 200 Costa Mesa, CA 92626 (949) 336-5979 blawson@urbanxroads.com EDUCATION Master of Science in Civil and Environmental Engineering California Polytechnic State University, San Luis Obispo • December, 1993 Bachelor of Science in City and Regional Planning California Polytechnic State University, San Luis Obispo • June, 1992 PROFESSIONAL REGISTRATIONS PE – Registered Professional Traffic Engineer – TR 2537 • January, 2009 AICP – American Institute of Certified Planners – 013011 • June, 1997–January 1, 2012 PTP – Professional Transportation Planner • May, 2007 – May, 2013 INCE – Institute of Noise Control Engineering • March, 2004 PROFESSIONAL AFFILIATIONS ASA – Acoustical Society of America ITE – Institute of Transportation Engineers PROFESSIONAL CERTIFICATIONS Certified Acoustical Consultant – County of Orange • February, 2011 FHWA-NHI-142051 Highway Traffic Noise Certificate of Training • February, 2013 Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study 58 This page intentionally left blank Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study APPENDIX 3.1: CITY OF FONTANA DEVELOPMENT CODE 59 Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study This page intentionally left blank 60 Section No. 30-542 - Trash and Recycling Collection Areas. All trash receptacles and disposal areas shall be screened from view. All industrial facilities shall be provided with trash receptacles and recycling facilities as follows: 1. Number. An adequate number and size of receptacles shall be provided to serve all uses on a property. 2. Screening. All receptacles shall be screened and the trash enclosure that is designed pursuant to the City approved Conceptual Plan. The receptacle shall not be visible above the wall. The enclosure shall be architecturally compatible with the architecture of the proposed/existing structures. DIVISION 6. - PERFORMANCE STANDARDS Section No. 30-543 - Noise and Vibration. A. Noise Levels. No person shall create or cause to be created any sound which exceeds the noise levels in this Section as measured at the property line of any residentially zoned property: 1. The noise level between 7:00 a.m. and 10:00 p.m. shall not exceed 70 db(A). 2. The noise level between 10:00 p.m. and 7:00 a.m. shall not exceed 65 db(A). B. Noise Measurements. Noise shall be measured with a sound level meter that meets the standards of the American National Standards Institute (ANSI) Section SI4-1979, Type 1 or Type 2. Noise levels shall be measured using the "A" weighted sound pressure level scale in decibels (reference pressure = 20 micronewtons per meter squared). C. Vibration. No person shall create or cause to be created any activity which causes a vibration which can be felt beyond the property line with or without the aid of an instrument. Section No. 30-544 - Light and Glare. All lights shall be directed and/or shielded to prevent the light from adversely affecting adjacent properties. No structure or lighting feature shall be permitted which creates adverse glare. A photometric plan shall be provided that indicates the amount of light emanating from the proposed/existing light fixtures. Section No. 30-545 - Odors. All uses shall be operated in a manner such that no offensive odor is perceptible at or beyond the property line of that use. Section No. 30-546 - Electromagnetic Interference. No use, activity, or process shall be conducted which produces electromagnetic interference with normal radio and television receptions beyond the property line of that use. 61 Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study This page intentionally left blank 62 Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study APPENDIX 5.1: STUDY AREA PHOTOS 63 Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study This page intentionally left blank 64 JN: 14467 Study Area Photos L1_E 34, 6' 38.090000"117, 28' 18.760000" L1_N 34, 6' 38.090000"117, 28' 18.820000" L1_S 34, 6' 38.090000"117, 28' 18.790000" L1_W 34, 6' 38.100000"117, 28' 18.820000" L2_E 34, 6' 34.830000"117, 28' 15.380000" L2_N 34, 6' 34.770000"117, 28' 15.360000" 65 JN: 14467 Study Area Photos L2_S 34, 6' 34.770000"117, 28' 15.410000" L2_W 34, 6' 34.820000"117, 28' 15.410000" L3_E 34, 6' 30.980000"117, 28' 7.910000" L3_N 34, 6' 31.000000"117, 28' 7.940000" L3_S 34, 6' 30.990000"117, 28' 7.940000" L3_W 34, 6' 30.980000"117, 28' 7.940000" 66 JN: 14467 Study Area Photos L4_E 34, 6' 22.760000"117, 28' 11.320000" L4_N 34, 6' 22.820000"117, 28' 11.370000" L4_S 34, 6' 22.780000"117, 28' 11.320000" L4_W 34, 6' 22.720000"117, 28' 11.370000" L5_E 34, 6' 22.710000"117, 28' 21.670000" L5_N 34, 6' 22.720000"117, 28' 21.700000" 67 JN: 14467 Study Area Photos L5_S 34, 6' 22.700000"117, 28' 21.700000" L5_W 34, 6' 22.700000"117, 28' 21.700000" L6_E 34, 6' 26.940000"117, 28' 23.160000" L6_N 34, 6' 26.970000"117, 28' 23.180000" L6_S 34, 6' 26.950000"117, 28' 23.160000" L6_W 34, 6' 26.970000"117, 28' 23.160000" 68 Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study APPENDIX 5.2: NOISE LEVEL MEASUREMENT WORKSHEETS 69 Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study This page intentionally left blank 70 Date:Location:Meter:Piccolo II JN:14467 Project:Beech Avenue Source:Analyst:A. Khan Timeframe Hour L eq Lmax Lmin L1%L2%L5%L8%L25%L50%L90%L95%L99%L eq Adj.Adj. Leq 0 49.5 55.7 46.0 55.4 55.0 53.9 53.2 49.7 48.1 46.5 46.3 46.1 49.5 10.0 59.5 1 46.5 52.7 43.9 52.3 51.7 50.0 48.9 46.6 45.6 44.5 44.2 44.0 46.5 10.0 56.5 2 44.9 49.1 43.4 48.5 47.9 46.9 46.4 45.2 44.5 43.8 43.6 43.4 44.9 10.0 54.9351.2 59.8 45.7 59.3 58.7 57.4 56.0 50.7 48.0 46.3 46.1 45.8 51.2 10.0 61.2451.7 57.4 48.1 57.0 56.8 55.9 55.0 52.2 50.5 48.8 48.4 48.1 51.7 10.0 61.7553.1 59.1 50.2 58.8 58.3 56.7 55.5 53.5 52.1 50.8 50.5 50.3 53.1 10.0 63.1654.9 60.7 51.6 60.2 59.8 58.4 57.4 55.5 54.2 52.2 51.9 51.7 54.9 10.0 64.9 7 56.3 62.9 53.4 62.4 61.9 60.0 58.8 56.3 55.2 53.9 53.7 53.5 56.3 0.0 56.3 8 52.6 59.5 50.1 59.2 58.7 56.6 55.2 52.3 51.3 50.5 50.3 50.1 52.6 0.0 52.6 9 50.2 59.0 44.5 58.6 58.0 55.6 53.7 50.6 47.6 45.3 45.0 44.7 50.2 0.0 50.2 10 48.7 59.2 43.0 58.3 57.5 54.8 52.7 47.6 45.6 43.8 43.5 43.1 48.7 0.0 48.7 11 50.1 60.6 44.8 60.1 59.2 55.9 53.8 49.1 47.1 45.3 45.1 44.9 50.1 0.0 50.11250.6 60.0 44.8 59.6 58.9 56.3 54.6 50.0 47.8 45.6 45.3 45.0 50.6 0.0 50.61350.9 59.1 45.7 58.6 58.0 55.9 54.6 51.0 48.8 46.6 46.2 45.8 50.9 0.0 50.91453.3 61.7 47.2 61.2 60.6 58.8 57.5 53.4 50.9 48.3 47.9 47.4 53.3 0.0 53.31550.8 58.7 45.2 58.3 57.7 55.9 54.5 51.3 48.6 46.1 45.7 45.4 50.8 0.0 50.8 16 49.8 59.7 43.6 59.3 58.7 56.1 53.8 48.9 46.7 44.4 44.1 43.7 49.8 0.0 49.8 17 51.0 61.7 43.7 61.1 60.2 57.2 55.4 50.1 46.9 44.4 44.2 43.8 51.0 0.0 51.0 18 49.2 57.6 43.8 57.3 56.7 54.8 53.1 49.4 46.6 44.4 44.2 43.9 49.2 0.0 49.2 19 48.5 56.9 43.4 56.5 55.9 54.0 52.5 48.4 46.2 44.2 43.9 43.5 48.5 5.0 53.52049.3 59.9 43.0 59.4 58.4 55.5 53.3 48.2 45.8 43.9 43.5 43.1 49.3 5.0 54.32148.9 58.3 43.0 58.0 57.4 55.2 53.4 48.0 45.6 43.6 43.3 43.1 48.9 5.0 53.92247.2 55.9 41.8 55.5 54.9 52.8 51.0 47.0 44.8 42.6 42.3 41.9 47.2 10.0 57.22346.7 55.8 41.0 55.5 54.9 53.1 51.0 46.1 43.6 41.7 41.4 41.1 46.7 10.0 56.7TimeframeHourLeqLmaxLminL1%L2%L5%L8%L25%L50%L90%L95%L99% Min 48.5 56.9 43.0 56.5 55.9 54.0 52.5 47.6 45.6 43.6 43.3 43.1 Max 56.3 62.9 53.4 62.4 61.9 60.0 58.8 56.3 55.2 53.9 53.7 53.5 51.2 59.2 58.5 56.2 54.5 50.3 48.0 46.0 45.7 45.4Min44.9 49.1 41.0 48.5 47.9 46.9 46.4 45.2 43.6 41.7 41.4 41.1Max54.9 60.7 51.6 60.2 59.8 58.4 57.4 55.5 54.2 52.2 51.9 51.750.7 55.8 55.3 53.9 52.7 49.6 47.9 46.3 46.1 45.8 Day Night Energy Average Energy Average Average: Average: 24-Hour Daytime (7am-10pm) Nighttime (10pm-7am) 51.0 51.2 50.7 24-Hour Noise Level Measurement Summary Hourly Leq dBA Readings (unadjusted) L eq (dBA) Night Wednesday, October 27, 2021 L1 - Located northwest of the Project site near single-family residence at 15247 Montanez Street. Night Day 49 . 5 46 . 5 44 . 9 51 . 2 51 . 7 53 . 1 54 . 9 56 . 3 52 . 6 50 . 2 48 . 7 50 . 1 50 . 6 50 . 9 53 . 3 50 . 8 49 . 8 51 . 0 49 . 2 48 . 5 49 . 3 48 . 9 47 . 2 46 . 7 35.040.045.050.055.060.065.070.075.080.085.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Ho u r l y L eq (d B A ) Hour Beginning Z:\Shared\UcJobs\_14100-14500\_14400\14467\04_Noise\Fieldwork\Measurements\14467_L1_Y 71 Date:Location:Meter:Piccolo II JN:14467 Project:Beech Avenue Source:Analyst:A. Khan Timeframe Hour L eq Lmax Lmin L1%L2%L5%L8%L25%L50%L90%L95%L99%L eq Adj.Adj. Leq 0 49.8 55.7 46.7 55.4 55.0 54.1 53.1 49.9 48.5 47.2 47.0 46.8 49.8 10.0 59.8 1 46.2 51.3 44.2 51.0 50.5 49.1 48.1 46.4 45.5 44.6 44.5 44.3 46.2 10.0 56.2 2 46.5 51.5 44.3 51.0 50.7 49.7 48.9 46.7 45.6 44.8 44.6 44.4 46.5 10.0 56.5350.9 58.6 46.7 58.3 57.7 56.4 55.0 50.8 48.6 47.2 47.0 46.8 50.9 10.0 60.9451.0 56.6 48.1 56.2 55.7 54.6 53.6 51.5 50.1 48.7 48.5 48.2 51.0 10.0 61.0552.9 58.3 49.9 57.9 57.4 56.0 55.2 53.4 52.2 50.6 50.3 50.0 52.9 10.0 62.9656.9 64.2 51.3 63.8 63.5 62.5 61.6 57.0 54.2 52.0 51.7 51.4 56.9 10.0 66.9 7 56.0 61.0 53.3 60.6 60.3 59.3 58.5 56.5 55.1 53.8 53.6 53.4 56.0 0.0 56.0 8 52.7 56.0 51.1 55.6 55.2 54.4 54.1 53.0 52.4 51.6 51.4 51.2 52.7 0.0 52.7 9 51.0 56.5 46.8 56.1 55.8 55.1 54.6 52.2 49.2 47.4 47.2 47.0 51.0 0.0 51.0 10 48.2 53.7 44.8 52.9 52.3 51.2 50.6 48.9 47.5 45.6 45.3 45.0 48.2 0.0 48.2 11 49.9 55.4 46.8 55.1 54.7 53.6 52.9 50.3 48.8 47.4 47.1 46.9 49.9 0.0 49.91249.9 55.0 46.6 54.6 54.2 53.2 52.5 50.6 49.1 47.4 47.1 46.7 49.9 0.0 49.91352.1 58.4 47.5 57.9 57.2 55.8 55.2 52.8 51.1 48.6 48.2 47.6 52.1 0.0 52.11452.9 60.0 47.7 59.6 59.1 57.6 56.5 53.4 51.4 48.6 48.3 47.9 52.9 0.0 52.91555.3 62.4 47.6 61.5 60.8 59.5 58.7 56.4 54.3 50.5 49.6 48.2 55.3 0.0 55.3 16 49.0 55.6 44.3 55.2 54.7 53.3 52.5 49.6 47.4 45.2 44.8 44.4 49.0 0.0 49.0 17 52.2 64.1 45.1 63.2 62.4 58.1 55.1 50.8 48.3 46.1 45.7 45.2 52.2 0.0 52.2 18 48.6 54.8 45.0 54.4 53.7 52.1 51.4 49.1 47.5 45.7 45.4 45.2 48.6 0.0 48.6 19 48.4 54.6 44.4 54.2 53.8 52.8 52.2 49.0 46.8 45.1 44.8 44.5 48.4 5.0 53.42047.1 53.0 43.5 52.5 51.9 50.6 49.9 47.7 46.1 44.2 44.0 43.6 47.1 5.0 52.12148.2 54.2 44.3 53.8 53.4 52.3 51.7 48.8 46.8 45.0 44.7 44.4 48.2 5.0 53.22247.8 53.7 43.7 53.3 52.7 51.6 50.8 48.5 46.5 44.5 44.2 43.8 47.8 10.0 57.82346.3 52.4 42.5 52.0 51.5 50.2 49.5 47.0 45.0 43.1 42.9 42.6 46.3 10.0 56.3TimeframeHourLeqLmaxLminL1%L2%L5%L8%L25%L50%L90%L95%L99% Min 47.1 53.0 43.5 52.5 51.9 50.6 49.9 47.7 46.1 44.2 44.0 43.6 Max 56.0 64.1 53.3 63.2 62.4 59.5 58.7 56.5 55.1 53.8 53.6 53.4 51.6 56.5 55.9 54.6 53.8 51.3 49.5 47.5 47.2 46.7Min46.2 51.3 42.5 51.0 50.5 49.1 48.1 46.4 45.0 43.1 42.9 42.6Max56.9 64.2 51.3 63.8 63.5 62.5 61.6 57.0 54.2 52.0 51.7 51.451.3 55.4 55.0 53.8 52.9 50.1 48.5 47.0 46.7 46.5 24-Hour Noise Level Measurement Summary Hourly Leq dBA Readings (unadjusted) L eq (dBA) Night Wednesday, October 27, 2021 L2 - Located north of the Project site near a child's playground southwest of Parsley Leaf Place. Night Day Day Night Energy Average Energy Average Average: Average: 24-Hour Daytime (7am-10pm) Nighttime (10pm-7am) 51.5 51.6 51.3 49 . 8 46 . 2 46 . 5 50 . 9 51 . 0 52 . 9 56 . 9 56 . 0 52 . 7 51 . 0 48 . 2 49 . 9 49 . 9 52 . 1 52 . 9 55 . 3 49 . 0 52 . 2 48 . 6 48 . 4 47 . 1 48 . 2 47 . 8 46 . 3 35.040.045.050.055.060.065.070.075.080.085.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Ho u r l y L eq (d B A ) Hour Beginning Z:\Shared\UcJobs\_14100-14500\_14400\14467\04_Noise\Fieldwork\Measurements\14467_L2_X 72 Date:Location:Meter:Piccolo II JN:14467 Project:Beech Avenue Source:Analyst:A. Khan Timeframe Hour L eq Lmax Lmin L1%L2%L5%L8%L25%L50%L90%L95%L99%L eq Adj.Adj. Leq 0 56.7 81.7 51.6 81.2 80.1 74.7 69.9 56.6 52.8 51.9 51.8 51.7 56.7 10.0 66.7 1 57.5 69.3 50.5 69.0 68.2 64.7 61.8 53.8 51.6 50.8 50.7 50.6 57.5 10.0 67.5 2 57.0 68.6 50.7 68.2 67.4 64.1 61.7 53.6 51.7 51.0 50.9 50.8 57.0 10.0 67.0359.9 72.0 51.5 71.6 70.8 67.2 64.3 56.3 53.0 51.8 51.7 51.5 59.9 10.0 69.9461.4 72.6 52.9 72.2 71.6 68.6 66.6 58.9 55.1 53.3 53.1 52.9 61.4 10.0 71.4563.3 73.2 54.0 72.9 72.3 70.0 68.4 62.9 57.9 54.7 54.3 54.0 63.3 10.0 73.3665.6 75.5 55.4 75.1 74.4 72.1 70.3 65.8 61.4 56.3 55.9 55.5 65.6 10.0 75.6 7 69.1 78.3 58.1 77.9 77.2 75.5 74.1 69.3 65.7 59.9 58.9 58.2 69.1 0.0 69.1 8 66.0 74.7 54.9 74.3 73.6 71.6 70.6 67.2 62.8 56.0 55.4 55.0 66.0 0.0 66.0 9 63.5 73.2 51.8 72.9 72.2 70.2 68.8 63.7 57.7 52.6 52.2 51.9 63.5 0.0 63.5 10 64.4 75.8 50.9 75.3 74.4 71.4 69.1 63.8 57.9 51.7 51.2 51.0 64.4 0.0 64.4 11 63.9 73.9 51.1 73.5 72.5 70.1 68.7 64.4 59.4 52.1 51.5 51.1 63.9 0.0 63.91262.6 72.3 50.6 72.0 71.3 69.0 67.6 63.2 57.6 51.6 51.1 50.7 62.6 0.0 62.61364.8 75.5 51.1 75.1 74.2 71.2 69.7 65.1 59.2 52.2 51.6 51.2 64.8 0.0 64.81464.4 73.5 52.2 73.2 72.5 70.2 68.9 65.4 60.7 53.7 52.9 52.4 64.4 0.0 64.41565.7 77.1 51.2 76.4 75.5 72.2 70.0 65.6 60.6 52.3 51.8 51.3 65.7 0.0 65.7 16 65.4 75.1 51.3 74.7 73.9 71.3 69.8 66.4 61.8 52.9 52.1 51.4 65.4 0.0 65.4 17 65.0 73.6 51.2 73.3 72.6 70.9 69.5 66.1 62.3 53.1 51.9 51.3 65.0 0.0 65.0 18 66.3 78.5 51.5 78.0 76.8 72.9 70.3 65.2 60.8 53.0 52.2 51.6 66.3 0.0 66.3 19 63.6 74.2 50.4 73.7 72.8 70.2 68.4 63.6 57.7 51.5 51.0 50.5 63.6 5.0 68.62062.0 72.3 49.7 72.0 71.2 68.7 67.2 62.0 55.3 50.5 50.1 49.8 62.0 5.0 67.02161.8 73.4 49.4 72.9 71.9 68.8 66.9 60.8 53.5 50.0 49.8 49.5 61.8 5.0 66.82260.0 81.1 48.9 80.0 78.3 72.0 65.5 56.8 51.8 49.5 49.2 48.9 60.0 10.0 70.02358.8 70.5 48.4 70.1 69.3 66.4 64.3 55.2 50.7 48.9 48.7 48.4 58.8 10.0 68.8TimeframeHourLeqLmaxLminL1%L2%L5%L8%L25%L50%L90%L95%L99% Min 61.8 72.3 49.4 72.0 71.2 68.7 66.9 60.8 53.5 50.0 49.8 49.5 Max 69.1 78.5 58.1 78.0 77.2 75.5 74.1 69.3 65.7 59.9 58.9 58.2 65.0 74.3 73.5 70.9 69.3 64.8 59.5 52.9 52.2 51.8Min56.7 68.6 48.4 68.2 67.4 64.1 61.7 53.6 50.7 48.9 48.7 48.4Max65.6 81.7 55.4 81.2 80.1 74.7 70.3 65.8 61.4 56.3 55.9 55.561.0 73.4 72.5 68.9 65.9 57.8 54.0 52.0 51.8 51.6 Day Night Energy Average Energy Average Average: Average: 24-Hour Daytime (7am-10pm) Nighttime (10pm-7am) 63.9 65.0 61.0 24-Hour Noise Level Measurement Summary Hourly Leq dBA Readings (unadjusted) L eq (dBA) Night Wednesday, October 27, 2021 L3 - Located northeast of the Project site near single-family residence at 15459 Vanilla Bean Lane. Night Day 56 . 7 57 . 5 57 . 0 59 . 9 61 . 4 63 . 3 65 . 6 69 . 1 66 . 0 63 . 5 64 . 4 63 . 9 62 . 6 64 . 8 64 . 4 65 . 7 65 . 4 65 . 0 66 . 3 63 . 6 62 . 0 61 . 8 60 . 0 58 . 8 35.040.045.050.055.060.065.070.075.080.085.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Ho u r l y L eq (d B A ) Hour Beginning Z:\Shared\UcJobs\_14100-14500\_14400\14467\04_Noise\Fieldwork\Measurements\14467_L3_B 73 Date:Location:Meter:Piccolo II JN:14467 Project:Beech Avenue Source:Analyst:A. Khan Timeframe Hour L eq Lmax Lmin L1%L2%L5%L8%L25%L50%L90%L95%L99%L eq Adj.Adj. Leq 0 62.2 73.3 49.9 72.9 72.0 69.2 67.2 61.3 55.7 50.7 50.3 49.9 62.2 10.0 72.2 1 60.3 71.6 46.8 71.2 70.4 67.5 65.5 59.2 52.9 47.7 47.3 46.9 60.3 10.0 70.3 2 62.5 74.1 46.9 73.9 73.1 70.0 67.7 60.5 54.3 48.5 47.7 47.1 62.5 10.0 72.5363.9 74.0 49.6 73.6 73.0 70.7 69.3 63.8 58.5 51.3 50.3 49.8 63.9 10.0 73.9466.6 75.9 54.1 75.6 75.0 72.9 71.4 67.0 62.8 55.9 54.9 54.3 66.6 10.0 76.6568.0 76.4 56.4 76.0 75.3 73.5 72.4 69.0 65.3 58.5 57.3 56.6 68.0 10.0 78.0669.8 79.4 59.1 78.9 78.1 76.0 74.4 69.9 66.6 61.1 60.2 59.3 69.8 10.0 79.8 7 70.3 78.9 61.6 78.5 77.8 75.7 74.3 70.7 68.4 63.7 62.8 61.9 70.3 0.0 70.3 8 69.7 79.1 58.9 78.6 77.9 75.2 73.7 70.3 67.1 61.2 60.1 59.0 69.7 0.0 69.7 9 69.3 79.1 55.9 78.7 78.1 75.6 73.8 69.4 65.9 59.1 57.6 56.2 69.3 0.0 69.3 10 68.1 77.1 55.6 76.7 75.8 73.7 72.1 68.8 65.7 58.6 57.2 56.0 68.1 0.0 68.1 11 70.2 81.4 57.1 81.0 80.1 77.0 74.2 69.5 66.2 59.7 58.5 57.4 70.2 0.0 70.21269.9 80.5 57.8 79.9 79.2 76.6 74.1 69.4 66.2 60.4 59.3 58.1 69.9 0.0 69.91369.4 77.1 59.3 76.7 76.1 74.3 73.3 70.3 67.6 62.3 61.0 59.5 69.4 0.0 69.41469.8 78.1 60.3 77.6 77.0 75.2 73.9 70.4 67.7 63.0 61.8 60.6 69.8 0.0 69.81570.7 79.0 60.8 78.5 77.9 76.0 74.7 71.3 68.5 63.4 62.2 61.0 70.7 0.0 70.7 16 72.6 83.9 60.5 83.4 82.8 80.0 77.1 70.7 67.9 63.3 62.1 60.9 72.6 0.0 72.6 17 71.2 81.9 60.7 81.5 80.6 77.2 75.0 70.8 68.0 63.0 62.0 60.9 71.2 0.0 71.2 18 70.2 80.6 58.0 80.2 79.3 76.7 74.5 69.9 66.9 61.1 59.6 58.3 70.2 0.0 70.2 19 68.9 79.1 55.7 78.6 77.7 74.8 73.0 69.1 65.9 58.9 57.2 55.9 68.9 5.0 73.92067.4 77.1 54.5 76.8 76.0 73.2 71.6 67.9 64.0 57.1 55.9 54.7 67.4 5.0 72.42168.2 78.7 54.0 78.1 77.3 75.3 73.5 67.6 63.7 56.4 55.2 54.2 68.2 5.0 73.22265.7 75.4 50.9 75.0 74.4 72.3 70.5 65.9 61.6 53.8 52.3 51.1 65.7 10.0 75.72365.9 77.1 49.8 76.7 75.9 73.2 70.8 65.1 59.8 51.8 50.7 50.0 65.9 10.0 75.9TimeframeHourLeqLmaxLminL1%L2%L5%L8%L25%L50%L90%L95%L99% Min 67.4 77.1 54.0 76.7 75.8 73.2 71.6 67.6 63.7 56.4 55.2 54.2 Max 72.6 83.9 61.6 83.4 82.8 80.0 77.1 71.3 68.5 63.7 62.8 61.9 69.9 79.0 78.2 75.8 73.9 69.7 66.6 60.7 59.5 58.3Min60.3 71.6 46.8 71.2 70.4 67.5 65.5 59.2 52.9 47.7 47.3 46.9Max69.8 79.4 59.1 78.9 78.1 76.0 74.4 69.9 66.6 61.1 60.2 59.365.9 74.9 74.1 71.7 69.9 64.6 59.7 53.3 52.3 51.7 24-Hour Noise Level Measurement Summary Hourly Leq dBA Readings (unadjusted) L eq (dBA) Night Wednesday, October 27, 2021 L4 - Located southeast of the Project site near single-family residence at 15357 Foothill Boulevard. Night Day Day Night Energy Average Energy Average Average: Average: 24-Hour Daytime (7am-10pm) Nighttime (10pm-7am) 68.8 69.9 65.9 62 . 2 60 . 3 62 . 5 63 . 9 66 . 6 68 . 0 69 . 8 70 . 3 69 . 7 69 . 3 68 . 1 70 . 2 69 . 9 69 . 4 69 . 8 70 . 7 72 . 6 71 . 2 70 . 2 68 . 9 67 . 4 68 . 2 65 . 7 65 . 9 35.040.045.050.055.060.065.070.075.080.085.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Ho u r l y L eq (d B A ) Hour Beginning Z:\Shared\UcJobs\_14100-14500\_14400\14467\04_Noise\Fieldwork\Measurements\14467_L4_F 74 Date:Location:Meter:Piccolo II JN:14467 Project:Beech Avenue Source:Analyst:A. Khan Timeframe Hour L eq Lmax Lmin L1%L2%L5%L8%L25%L50%L90%L95%L99%L eq Adj.Adj. Leq 0 63.4 75.2 52.5 74.5 73.5 70.5 68.3 61.6 56.7 53.3 52.9 52.6 63.4 10.0 73.4 1 62.4 74.3 49.9 73.5 72.6 69.6 67.5 60.9 55.1 50.5 50.3 50.0 62.4 10.0 72.4 2 63.2 75.0 49.7 74.3 73.2 70.4 68.6 61.3 56.1 51.1 50.3 49.9 63.2 10.0 73.2365.8 77.1 51.3 76.5 75.6 72.9 70.9 65.1 59.5 52.4 51.8 51.4 65.8 10.0 75.8468.5 79.4 55.9 78.6 77.6 74.5 72.7 68.7 64.5 57.8 56.9 56.0 68.5 10.0 78.5569.5 78.9 58.2 78.4 77.6 75.0 73.4 70.0 66.9 61.0 59.7 58.5 69.5 10.0 79.5671.0 80.3 59.7 79.7 78.9 76.6 75.3 71.6 68.3 62.1 60.8 59.8 71.0 10.0 81.0 7 71.8 80.8 62.6 80.2 79.3 77.1 75.7 72.4 69.7 64.7 63.8 62.8 71.8 0.0 71.8 8 71.5 80.8 60.2 80.0 79.0 77.0 75.7 72.2 68.9 62.7 61.6 60.6 71.5 0.0 71.5 9 70.1 80.0 55.3 79.4 78.4 76.2 74.7 70.7 66.9 58.6 57.1 55.5 70.1 0.0 70.1 10 70.1 80.1 55.6 79.4 78.5 76.0 74.4 70.6 67.0 58.8 57.3 56.0 70.1 0.0 70.1 11 71.9 84.5 56.6 83.7 82.5 78.0 75.3 70.9 67.4 59.8 58.5 56.8 71.9 0.0 71.91270.0 78.7 57.8 78.1 77.2 75.4 74.2 71.0 67.9 60.6 59.5 58.1 70.0 0.0 70.01371.2 80.2 60.0 79.6 78.6 76.5 75.1 72.0 69.0 62.5 61.4 60.2 71.2 0.0 71.21471.8 81.1 62.1 80.4 79.4 76.9 75.6 72.4 69.6 64.3 63.3 62.3 71.8 0.0 71.81571.9 80.8 61.8 80.2 79.3 77.0 75.6 72.5 70.0 64.5 63.3 62.1 71.9 0.0 71.9 16 74.1 86.4 60.9 85.6 84.2 80.5 77.7 72.7 70.0 63.8 62.2 61.1 74.1 0.0 74.1 17 72.7 83.7 59.8 82.8 82.1 78.9 76.5 72.3 69.6 63.1 61.5 60.1 72.7 0.0 72.7 18 71.8 82.8 59.7 81.9 80.7 77.7 75.7 71.7 68.8 63.0 61.4 60.0 71.8 0.0 71.8 19 71.6 84.1 55.8 83.3 81.9 77.8 75.1 70.6 66.9 58.8 57.1 56.1 71.6 5.0 76.62069.4 79.7 54.9 78.8 77.8 75.2 73.5 70.0 66.4 57.9 56.2 55.1 69.4 5.0 74.42170.5 82.0 55.7 81.3 80.2 77.3 74.5 70.2 65.6 58.1 56.9 55.9 70.5 5.0 75.52268.0 78.4 54.1 77.7 76.7 74.3 73.0 68.3 63.6 56.1 55.2 54.3 68.0 10.0 78.02366.2 76.8 52.5 76.1 75.2 72.9 71.2 66.2 61.0 54.2 53.4 52.7 66.2 10.0 76.2TimeframeHourLeqLmaxLminL1%L2%L5%L8%L25%L50%L90%L95%L99% Min 69.4 78.7 54.9 78.1 77.2 75.2 73.5 70.0 65.6 57.9 56.2 55.1 Max 74.1 86.4 62.6 85.6 84.2 80.5 77.7 72.7 70.0 64.7 63.8 62.8 71.5 81.0 80.0 77.2 75.3 71.5 68.2 61.4 60.1 58.8Min62.4 74.3 49.7 73.5 72.6 69.6 67.5 60.9 55.1 50.5 50.3 49.9Max71.0 80.3 59.7 79.7 78.9 76.6 75.3 71.6 68.3 62.1 60.8 59.867.3 76.6 75.6 73.0 71.2 66.0 61.3 55.4 54.6 53.9 24-Hour Noise Level Measurement Summary Hourly Leq dBA Readings (unadjusted) L eq (dBA) Night Wednesday, October 27, 2021 L5 - Located southwest of the Project site near Sunset Motel at 15243 Foothill Boulevard. Night Day Day Night Energy Average Energy Average Average: Average: 24-Hour Daytime (7am-10pm) Nighttime (10pm-7am) 70.4 71.5 67.3 63 . 4 62 . 4 63 . 2 65 . 8 68 . 5 69 . 5 71 . 0 71 . 8 71 . 5 70 . 1 70 . 1 71 . 9 70 . 0 71 . 2 71 . 8 71 . 9 74 . 1 72 . 7 71 . 8 71 . 6 69 . 4 70 . 5 68 . 0 66 . 2 35.040.045.050.055.060.065.070.075.080.085.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Ho u r l y L eq (d B A ) Hour Beginning Z:\Shared\UcJobs\_14100-14500\_14400\14467\04_Noise\Fieldwork\Measurements\14467_L5_D 75 Date:Location:Meter:Piccolo II JN:14467 Project:Beech Avenue Source:Analyst:A. Khan Timeframe Hour L eq Lmax Lmin L1%L2%L5%L8%L25%L50%L90%L95%L99%L eq Adj.Adj. Leq 0 52.8 59.3 49.1 58.8 58.2 56.9 56.3 53.3 51.3 49.6 49.4 49.1 52.8 10.0 62.8 1 50.0 56.5 45.6 56.0 55.5 54.5 53.9 50.4 47.9 46.2 45.9 45.7 50.0 10.0 60.0 2 50.8 59.0 45.7 58.3 57.5 56.2 55.3 50.8 48.5 46.4 46.1 45.8 50.8 10.0 60.8353.9 60.4 49.1 60.0 59.6 58.2 57.3 54.6 52.4 49.9 49.6 49.2 53.9 10.0 63.9455.9 62.9 51.2 62.5 62.0 60.4 59.2 56.4 54.4 52.1 51.8 51.3 55.9 10.0 65.9557.3 62.9 53.1 62.5 62.0 61.0 60.1 58.0 56.5 54.1 53.6 53.2 57.3 10.0 67.3659.0 64.9 54.6 64.6 64.1 62.9 62.2 59.8 58.0 55.6 55.2 54.8 59.0 10.0 69.0 7 59.2 63.9 56.2 63.5 63.1 62.2 61.6 59.8 58.6 57.0 56.6 56.3 59.2 0.0 59.2 8 56.1 60.6 52.9 60.3 59.9 59.0 58.5 56.8 55.3 53.6 53.4 53.0 56.1 0.0 56.1 9 54.0 60.0 49.2 59.6 59.1 58.1 57.4 54.7 52.9 50.2 49.8 49.4 54.0 0.0 54.0 10 52.5 58.8 47.9 58.3 57.7 56.4 55.5 53.2 51.5 48.9 48.4 48.0 52.5 0.0 52.5 11 54.0 61.5 49.3 61.0 60.2 58.7 57.9 54.3 52.2 50.1 49.8 49.4 54.0 0.0 54.01252.1 57.1 48.6 56.7 56.2 55.3 54.7 52.9 51.3 49.3 49.0 48.7 52.1 0.0 52.11351.4 56.0 48.4 55.6 55.1 54.2 53.5 52.0 50.9 49.1 48.8 48.5 51.4 0.0 51.41453.1 57.6 49.8 57.3 56.9 56.2 55.6 53.7 52.4 50.6 50.3 49.9 53.1 0.0 53.11552.4 57.7 48.7 57.3 56.9 55.8 55.0 53.1 51.6 49.5 49.2 48.8 52.4 0.0 52.4 16 52.7 60.2 47.6 59.6 59.0 57.5 56.5 53.1 51.0 48.6 48.2 47.7 52.7 0.0 52.7 17 53.2 59.5 48.3 59.1 58.7 57.6 56.8 53.8 51.7 49.3 48.9 48.5 53.2 0.0 53.2 18 54.3 61.0 49.1 60.7 60.2 59.0 58.3 54.8 52.6 49.9 49.6 49.2 54.3 0.0 54.3 19 53.6 61.5 47.8 61.1 60.6 58.8 57.6 53.8 51.4 48.7 48.3 47.9 53.6 5.0 58.62051.4 58.2 46.9 57.8 57.2 55.9 54.7 52.0 50.1 47.7 47.4 47.0 51.4 5.0 56.42151.7 59.5 46.8 58.8 58.2 56.5 55.2 52.1 49.6 47.5 47.2 46.9 51.7 5.0 56.72250.0 56.2 45.5 55.8 55.3 54.3 53.5 50.5 48.5 46.3 46.0 45.6 50.0 10.0 60.02349.0 55.5 44.3 55.1 54.7 53.5 52.8 49.5 47.5 45.1 44.7 44.4 49.0 10.0 59.0TimeframeHourLeqLmaxLminL1%L2%L5%L8%L25%L50%L90%L95%L99% Min 51.4 56.0 46.8 55.6 55.1 54.2 53.5 52.0 49.6 47.5 47.2 46.9 Max 59.2 63.9 56.2 63.5 63.1 62.2 61.6 59.8 58.6 57.0 56.6 56.3 54.0 59.1 58.6 57.4 56.6 54.0 52.2 50.0 49.7 49.3Min49.0 55.5 44.3 55.1 54.7 53.5 52.8 49.5 47.5 45.1 44.7 44.4Max59.0 64.9 54.6 64.6 64.1 62.9 62.2 59.8 58.0 55.6 55.2 54.854.5 59.3 58.8 57.5 56.7 53.7 51.7 49.5 49.1 48.8 24-Hour Noise Level Measurement Summary Hourly Leq dBA Readings (unadjusted) L eq (dBA) Night Wednesday, October 27, 2021 L6 - Located southwest of the Project site near Forty Winks Motel at 15210 Foothill Boulevard. Night Day Day Night Energy Average Energy Average Average: Average: 24-Hour Daytime (7am-10pm) Nighttime (10pm-7am) 54.2 54.0 54.5 52 . 8 50 . 0 50 . 8 53 . 9 55 . 9 57 . 3 59 . 0 59 . 2 56 . 1 54 . 0 52 . 5 54 . 0 52 . 1 51 . 4 53 . 1 52 . 4 52 . 7 53 . 2 54 . 3 53 . 6 51 . 4 51 . 7 50 . 0 49 . 0 35.040.045.050.055.060.065.070.075.080.085.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Ho u r l y L eq (d B A ) Hour Beginning Z:\Shared\UcJobs\_14100-14500\_14400\14467\04_Noise\Fieldwork\Measurements\14467_L6_M 76 Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study APPENDIX 7.1: OFF-SITE TRAFFIC NOISE CONTOURS 77 Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study This page intentionally left blank 78 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:n/o Foothill Bl. (SR-66) Road Name:Cherry Av. Scenario:E 27,002 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,700 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 1.44 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -15.36 0.11 -1.20 0.000 0.000 86.40 -16.19 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 72.1 70.2 68.4 62.8 71.871.2 66.0 69.1 64.4 56.7 57.2 65.565.3 67.1 57.7 63.0 70.170.0 Vehicle Noise:74.5 72.6 69.0 66.5 74.674.3 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 127 274 1,271590 134 288 1,339621 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:n/o Foothill Bl. (SR-66) Road Name:Cherry Av. Scenario:E+P 27,054 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,705 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 1.45 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.27% 84.5%3.6%11.9%2.02% 76.1%2.2%21.7%1.71% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -15.34 0.11 -1.20 0.000 0.000 86.40 -16.05 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 72.1 70.2 68.4 62.8 71.871.2 66.0 69.3 64.5 56.8 57.2 65.565.3 67.3 57.9 63.1 70.270.2 Vehicle Noise:74.6 72.7 69.0 66.5 74.774.3 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 128 276 1,283595 135 291 1,350627 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:n/o Foothill Bl. (SR-66) Road Name:Cherry Av. Scenario:OY 30,847 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:3,085 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 2.02 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -14.78 0.11 -1.20 0.000 0.000 86.40 -15.61 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 72.7 70.7 69.0 63.4 72.471.8 66.5 69.7 65.0 57.3 57.7 66.065.9 67.7 58.3 63.5 70.770.6 Vehicle Noise:75.1 73.2 69.6 67.0 75.274.8 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 139 299 1,389645 146 315 1,463679 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:n/o Foothill Bl. (SR-66) Road Name:Cherry Av. Scenario:OY+P 30,898 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:3,090 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 2.03 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.27% 84.5%3.6%11.9%2.02% 76.1%2.2%21.7%1.71% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -14.76 0.11 -1.20 0.000 0.000 86.40 -15.48 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 72.7 70.7 69.0 63.4 72.471.8 66.6 69.8 65.0 57.3 57.8 66.165.9 67.8 58.4 63.7 70.870.7 Vehicle Noise:75.1 73.3 69.6 67.1 75.274.9 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 140 302 1,400650 147 318 1,474684 Tuesday, October 11, 2022 79 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:s/o Foothill Bl. (SR-66) Road Name:Cherry Av. Scenario:E 25,477 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,548 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 1.19 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -15.62 0.11 -1.20 0.000 0.000 86.40 -16.44 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 71.9 69.9 68.2 62.6 71.671.0 65.7 68.9 64.2 56.5 56.9 65.265.1 66.9 57.5 62.7 69.869.8 Vehicle Noise:74.3 72.4 68.8 66.2 74.474.0 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 122 263 1,223568 129 277 1,288598 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:s/o Foothill Bl. (SR-66) Road Name:Cherry Av. Scenario:E+P 25,556 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,556 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 1.20 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.16% 84.5%3.6%11.9%2.04% 76.1%2.2%21.7%1.80% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -15.55 0.11 -1.20 0.000 0.000 86.40 -16.08 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 71.9 69.9 68.2 62.6 71.671.0 65.8 69.2 64.2 56.6 57.0 65.365.1 67.3 57.8 63.1 70.270.1 Vehicle Noise:74.4 72.5 68.8 66.4 74.574.2 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 125 270 1,252581 132 284 1,317611 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:s/o Foothill Bl. (SR-66) Road Name:Cherry Av. Scenario:OY 28,966 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,897 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 1.75 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -15.06 0.11 -1.20 0.000 0.000 86.40 -15.88 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 72.4 70.5 68.7 63.1 72.171.5 66.3 69.4 64.7 57.0 57.5 65.865.6 67.4 58.0 63.3 70.470.3 Vehicle Noise:74.8 72.9 69.3 66.8 74.974.6 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 133 287 1,332618 140 302 1,403651 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:s/o Foothill Bl. (SR-66) Road Name:Cherry Av. Scenario:OY+P 29,045 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,904 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 1.75 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.18% 84.5%3.6%11.9%2.03% 76.1%2.2%21.7%1.79% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -15.00 0.11 -1.20 0.000 0.000 86.40 -15.56 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 72.4 70.5 68.7 63.2 72.171.5 66.3 69.7 64.8 57.1 57.5 65.865.7 67.8 58.3 63.6 70.770.7 Vehicle Noise:74.9 73.0 69.4 66.9 75.074.7 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 136 293 1,360631 143 308 1,430664 Tuesday, October 11, 2022 80 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:s/o Foothill Bl. (SR-66) Road Name:Redwood Av. Scenario:E 3,640 10.00% 34.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:364 vehicles Centerline Dist. to Barrier: 34.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 45 mphVehicle Speed: Near/Far Lane Distance:14 feet REMEL Traffic Flow Distance -6.39 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 2.48 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 79.45 -23.20 2.53 -1.20 0.000 0.000 84.25 -24.02 2.52 -1.20 0.000 0.000 -4.53 -4.86 -5.67 Medium Trucks: Heavy Trucks: Autos: 68.46 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 33.645 33.381 33.407 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 63.3 61.4 59.6 54.1 63.062.5 57.6 61.6 56.1 48.4 48.8 57.156.9 59.6 50.2 55.4 62.562.5 Vehicle Noise:66.2 64.3 60.4 58.3 66.466.0 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 19 40 18586 19 42 19490 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:s/o Foothill Bl. (SR-66) Road Name:Redwood Av. Scenario:E+P 3,656 10.00% 34.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:366 vehicles Centerline Dist. to Barrier: 34.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 45 mphVehicle Speed: Near/Far Lane Distance:14 feet REMEL Traffic Flow Distance -6.37 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.34% 84.5%3.6%11.9%2.00% 76.1%2.2%21.7%1.66% 2.48 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 79.45 -23.20 2.53 -1.20 0.000 0.000 84.25 -24.02 2.52 -1.20 0.000 0.000 -4.53 -4.86 -5.67 Medium Trucks: Heavy Trucks: Autos: 68.46 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 33.645 33.381 33.407 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 63.4 61.4 59.7 54.1 63.162.5 57.6 61.6 56.1 48.4 48.8 57.156.9 59.6 50.2 55.4 62.562.5 Vehicle Noise:66.2 64.3 60.4 58.3 66.466.1 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 19 40 18586 19 42 19490 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:s/o Foothill Bl. (SR-66) Road Name:Redwood Av. Scenario:OY 3,935 10.00% 34.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:393 vehicles Centerline Dist. to Barrier: 34.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 45 mphVehicle Speed: Near/Far Lane Distance:14 feet REMEL Traffic Flow Distance -6.05 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 2.48 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 79.45 -22.86 2.53 -1.20 0.000 0.000 84.25 -23.68 2.52 -1.20 0.000 0.000 -4.53 -4.86 -5.67 Medium Trucks: Heavy Trucks: Autos: 68.46 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 33.645 33.381 33.407 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 63.7 61.7 60.0 54.4 63.462.8 57.9 61.9 56.4 48.7 49.1 57.457.3 59.9 50.5 55.7 62.962.8 Vehicle Noise:66.5 64.6 60.7 58.6 66.766.4 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 20 42 19591 20 44 20595 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:s/o Foothill Bl. (SR-66) Road Name:Redwood Av. Scenario:OY+P 3,951 10.00% 34.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:395 vehicles Centerline Dist. to Barrier: 34.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 45 mphVehicle Speed: Near/Far Lane Distance:14 feet REMEL Traffic Flow Distance -6.03 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.34% 84.5%3.6%11.9%2.00% 76.1%2.2%21.7%1.66% 2.48 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 79.45 -22.86 2.53 -1.20 0.000 0.000 84.25 -23.68 2.52 -1.20 0.000 0.000 -4.53 -4.86 -5.67 Medium Trucks: Heavy Trucks: Autos: 68.46 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 33.645 33.381 33.407 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 63.7 61.8 60.0 54.4 63.462.8 57.9 61.9 56.4 48.7 49.1 57.457.3 59.9 50.5 55.7 62.962.8 Vehicle Noise:66.5 64.6 60.7 58.7 66.766.4 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 20 42 19591 20 44 20595 Tuesday, October 11, 2022 81 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:s/o Foothill Bl. (SR-66) Road Name:Hemlock Av. Scenario:E 2,048 10.00% 34.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:205 vehicles Centerline Dist. to Barrier: 34.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 45 mphVehicle Speed: Near/Far Lane Distance:14 feet REMEL Traffic Flow Distance -8.89 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 2.48 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 79.45 -25.69 2.53 -1.20 0.000 0.000 84.25 -26.52 2.52 -1.20 0.000 0.000 -4.53 -4.86 -5.67 Medium Trucks: Heavy Trucks: Autos: 68.46 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 33.645 33.381 33.407 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 60.9 58.9 57.1 51.6 60.560.0 55.1 59.1 53.6 45.9 46.3 54.654.4 57.1 47.7 52.9 60.060.0 Vehicle Noise:63.7 61.8 57.9 55.8 63.963.5 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 13 27 12659 13 29 13261 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:s/o Foothill Bl. (SR-66) Road Name:Hemlock Av. Scenario:E+P 2,065 10.00% 34.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:206 vehicles Centerline Dist. to Barrier: 34.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 45 mphVehicle Speed: Near/Far Lane Distance:14 feet REMEL Traffic Flow Distance -8.85 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.36% 84.5%3.6%11.9%1.99% 76.1%2.2%21.7%1.65% 2.48 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 79.45 -25.69 2.53 -1.20 0.000 0.000 84.25 -26.52 2.52 -1.20 0.000 0.000 -4.53 -4.86 -5.67 Medium Trucks: Heavy Trucks: Autos: 68.46 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 33.645 33.381 33.407 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 60.9 58.9 57.2 51.6 60.660.0 55.1 59.1 53.6 45.9 46.3 54.654.4 57.1 47.7 52.9 60.060.0 Vehicle Noise:63.7 61.8 57.9 55.8 63.963.6 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 13 27 12759 13 29 13362 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:s/o Foothill Bl. (SR-66) Road Name:Hemlock Av. Scenario:OY 2,279 10.00% 34.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:228 vehicles Centerline Dist. to Barrier: 34.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 45 mphVehicle Speed: Near/Far Lane Distance:14 feet REMEL Traffic Flow Distance -8.42 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 2.48 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 79.45 -25.23 2.53 -1.20 0.000 0.000 84.25 -26.05 2.52 -1.20 0.000 0.000 -4.53 -4.86 -5.67 Medium Trucks: Heavy Trucks: Autos: 68.46 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 33.645 33.381 33.407 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 61.3 59.4 57.6 52.0 61.060.4 55.5 59.5 54.0 46.3 46.8 55.154.9 57.5 48.1 53.4 60.560.4 Vehicle Noise:64.2 62.3 58.4 56.3 64.364.0 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 14 29 13663 14 31 14266 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:s/o Foothill Bl. (SR-66) Road Name:Hemlock Av. Scenario:OY+P 2,296 10.00% 34.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:230 vehicles Centerline Dist. to Barrier: 34.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 45 mphVehicle Speed: Near/Far Lane Distance:14 feet REMEL Traffic Flow Distance -8.39 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.35% 84.5%3.6%11.9%2.00% 76.1%2.2%21.7%1.65% 2.48 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 79.45 -25.23 2.53 -1.20 0.000 0.000 84.25 -26.05 2.52 -1.20 0.000 0.000 -4.53 -4.86 -5.67 Medium Trucks: Heavy Trucks: Autos: 68.46 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 33.645 33.381 33.407 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 61.3 59.4 57.6 52.1 61.060.5 55.5 59.5 54.0 46.3 46.8 55.154.9 57.5 48.1 53.4 60.560.4 Vehicle Noise:64.2 62.3 58.4 56.3 64.364.0 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 14 29 13663 14 31 14266 Tuesday, October 11, 2022 82 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:n/o Foothill Bl. (SR-66) Road Name:Almeria Av. Scenario:E 4,370 10.00% 34.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:437 vehicles Centerline Dist. to Barrier: 34.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 45 mphVehicle Speed: Near/Far Lane Distance:14 feet REMEL Traffic Flow Distance -5.60 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 2.48 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 79.45 -22.40 2.53 -1.20 0.000 0.000 84.25 -23.22 2.52 -1.20 0.000 0.000 -4.53 -4.86 -5.67 Medium Trucks: Heavy Trucks: Autos: 68.46 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 33.645 33.381 33.407 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 64.1 62.2 60.4 54.9 63.863.3 58.4 62.4 56.9 49.2 49.6 57.957.7 60.4 51.0 56.2 63.363.3 Vehicle Noise:67.0 65.1 61.2 59.1 67.166.8 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 21 45 20997 22 47 219102 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:n/o Foothill Bl. (SR-66) Road Name:Almeria Av. Scenario:E+P 4,404 10.00% 34.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:440 vehicles Centerline Dist. to Barrier: 34.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 45 mphVehicle Speed: Near/Far Lane Distance:14 feet REMEL Traffic Flow Distance -5.56 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.36% 84.5%3.6%11.9%1.99% 76.1%2.2%21.7%1.65% 2.48 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 79.45 -22.40 2.53 -1.20 0.000 0.000 84.25 -23.22 2.52 -1.20 0.000 0.000 -4.53 -4.86 -5.67 Medium Trucks: Heavy Trucks: Autos: 68.46 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 33.645 33.381 33.407 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 64.2 62.2 60.5 54.9 63.963.3 58.4 62.4 56.9 49.2 49.6 57.957.7 60.4 51.0 56.2 63.363.3 Vehicle Noise:67.0 65.1 61.2 59.1 67.266.9 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 21 45 21097 22 47 220102 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:n/o Foothill Bl. (SR-66) Road Name:Almeria Av. Scenario:OY 5,207 10.00% 34.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:521 vehicles Centerline Dist. to Barrier: 34.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 45 mphVehicle Speed: Near/Far Lane Distance:14 feet REMEL Traffic Flow Distance -4.83 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 2.48 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 79.45 -21.64 2.53 -1.20 0.000 0.000 84.25 -22.46 2.52 -1.20 0.000 0.000 -4.53 -4.86 -5.67 Medium Trucks: Heavy Trucks: Autos: 68.46 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 33.645 33.381 33.407 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 64.9 63.0 61.2 55.6 64.664.0 59.1 63.1 57.6 49.9 50.3 58.758.5 61.1 51.7 56.9 64.164.0 Vehicle Noise:67.8 65.9 61.9 59.9 67.967.6 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 24 51 235109 25 53 247114 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:n/o Foothill Bl. (SR-66) Road Name:Almeria Av. Scenario:OY+P 5,240 10.00% 34.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:524 vehicles Centerline Dist. to Barrier: 34.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 45 mphVehicle Speed: Near/Far Lane Distance:14 feet REMEL Traffic Flow Distance -4.81 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.35% 84.5%3.6%11.9%2.00% 76.1%2.2%21.7%1.65% 2.48 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 79.45 -21.64 2.53 -1.20 0.000 0.000 84.25 -22.46 2.52 -1.20 0.000 0.000 -4.53 -4.86 -5.67 Medium Trucks: Heavy Trucks: Autos: 68.46 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 33.645 33.381 33.407 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 64.9 63.0 61.2 55.7 64.664.0 59.1 63.1 57.6 49.9 50.3 58.758.5 61.1 51.7 56.9 64.164.0 Vehicle Noise:67.8 65.9 62.0 59.9 67.967.6 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 24 51 236109 25 53 247115 Tuesday, October 11, 2022 83 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:n/o Foothill Bl. (SR-66) Road Name:Citrus Av. Scenario:E 21,394 10.00% 52.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,139 vehicles Centerline Dist. to Barrier: 52.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 50 mphVehicle Speed: Near/Far Lane Distance:61 feet REMEL Traffic Flow Distance 0.85 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 0.97 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 81.00 -15.96 1.00 -1.20 0.000 0.000 85.38 -16.78 1.00 -1.20 0.000 0.000 -4.66 -4.87 -5.41 Medium Trucks: Heavy Trucks: Autos: 70.20 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 42.412 42.203 42.223 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 70.8 68.9 67.1 61.5 70.569.9 64.8 68.4 63.3 55.6 56.0 64.464.2 66.4 57.0 62.2 69.469.3 Vehicle Noise:73.4 71.5 67.8 65.4 73.573.2 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 85 184 852396 90 193 896416 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:n/o Foothill Bl. (SR-66) Road Name:Citrus Av. Scenario:E+P 21,453 10.00% 52.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,145 vehicles Centerline Dist. to Barrier: 52.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 50 mphVehicle Speed: Near/Far Lane Distance:61 feet REMEL Traffic Flow Distance 0.86 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.30% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.69% 0.97 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 81.00 -15.94 1.00 -1.20 0.000 0.000 85.38 -16.69 1.00 -1.20 0.000 0.000 -4.66 -4.87 -5.41 Medium Trucks: Heavy Trucks: Autos: 70.20 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 42.412 42.203 42.223 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 70.8 68.9 67.1 61.6 70.569.9 64.9 68.5 63.3 55.6 56.1 64.464.2 66.5 57.1 62.3 69.569.4 Vehicle Noise:73.5 71.6 67.8 65.5 73.673.3 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 86 185 858398 90 194 902418 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:n/o Foothill Bl. (SR-66) Road Name:Citrus Av. Scenario:OY 23,154 10.00% 52.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,315 vehicles Centerline Dist. to Barrier: 52.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 50 mphVehicle Speed: Near/Far Lane Distance:61 feet REMEL Traffic Flow Distance 1.19 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 0.97 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 81.00 -15.62 1.00 -1.20 0.000 0.000 85.38 -16.44 1.00 -1.20 0.000 0.000 -4.66 -4.87 -5.41 Medium Trucks: Heavy Trucks: Autos: 70.20 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 42.412 42.203 42.223 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 71.2 69.2 67.5 61.9 70.970.3 65.2 68.7 63.7 56.0 56.4 64.764.5 66.8 57.3 62.6 69.769.6 Vehicle Noise:73.8 71.9 68.1 65.8 73.973.6 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 90 194 898417 94 203 944438 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:n/o Foothill Bl. (SR-66) Road Name:Citrus Av. Scenario:OY+P 23,214 10.00% 52.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,321 vehicles Centerline Dist. to Barrier: 52.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 50 mphVehicle Speed: Near/Far Lane Distance:61 feet REMEL Traffic Flow Distance 1.20 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.30% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.69% 0.97 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 81.00 -15.60 1.00 -1.20 0.000 0.000 85.38 -16.36 1.00 -1.20 0.000 0.000 -4.66 -4.87 -5.41 Medium Trucks: Heavy Trucks: Autos: 70.20 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 42.412 42.203 42.223 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 71.2 69.2 67.5 61.9 70.970.3 65.2 68.8 63.7 56.0 56.4 64.764.6 66.8 57.4 62.6 69.869.7 Vehicle Noise:73.8 71.9 68.1 65.8 73.973.6 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 90 195 904420 95 205 950441 Tuesday, October 11, 2022 84 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:s/o Foothill Bl. (SR-66) Road Name:Citrus Av. Scenario:E 23,286 10.00% 52.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,329 vehicles Centerline Dist. to Barrier: 52.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 50 mphVehicle Speed: Near/Far Lane Distance:61 feet REMEL Traffic Flow Distance 1.21 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 0.97 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 81.00 -15.59 1.00 -1.20 0.000 0.000 85.38 -16.42 1.00 -1.20 0.000 0.000 -4.66 -4.87 -5.41 Medium Trucks: Heavy Trucks: Autos: 70.20 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 42.412 42.203 42.223 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 71.2 69.2 67.5 61.9 70.970.3 65.2 68.8 63.7 56.0 56.4 64.764.6 66.8 57.4 62.6 69.769.7 Vehicle Noise:73.8 71.9 68.2 65.8 73.973.6 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 90 194 902419 95 204 948440 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:s/o Foothill Bl. (SR-66) Road Name:Citrus Av. Scenario:E+P 23,366 10.00% 52.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,337 vehicles Centerline Dist. to Barrier: 52.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 50 mphVehicle Speed: Near/Far Lane Distance:61 feet REMEL Traffic Flow Distance 1.23 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.28% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.70% 0.97 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 81.00 -15.57 1.00 -1.20 0.000 0.000 85.38 -16.29 1.00 -1.20 0.000 0.000 -4.66 -4.87 -5.41 Medium Trucks: Heavy Trucks: Autos: 70.20 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 42.412 42.203 42.223 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 71.2 69.2 67.5 61.9 70.970.3 65.2 68.9 63.7 56.0 56.4 64.764.6 66.9 57.5 62.7 69.969.8 Vehicle Noise:73.8 71.9 68.2 65.9 74.073.6 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 91 196 910422 96 206 956444 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:s/o Foothill Bl. (SR-66) Road Name:Citrus Av. Scenario:OY 25,070 10.00% 52.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,507 vehicles Centerline Dist. to Barrier: 52.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 50 mphVehicle Speed: Near/Far Lane Distance:61 feet REMEL Traffic Flow Distance 1.53 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 0.97 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 81.00 -15.27 1.00 -1.20 0.000 0.000 85.38 -16.09 1.00 -1.20 0.000 0.000 -4.66 -4.87 -5.41 Medium Trucks: Heavy Trucks: Autos: 70.20 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 42.412 42.203 42.223 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 71.5 69.6 67.8 62.2 71.270.6 65.5 69.1 64.0 56.3 56.7 65.064.9 67.1 57.7 62.9 70.170.0 Vehicle Noise:74.1 72.2 68.5 66.1 74.273.9 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 95 204 947440 100 215 996462 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:s/o Foothill Bl. (SR-66) Road Name:Citrus Av. Scenario:OY+P 25,151 10.00% 52.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,515 vehicles Centerline Dist. to Barrier: 52.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 50 mphVehicle Speed: Near/Far Lane Distance:61 feet REMEL Traffic Flow Distance 1.55 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.29% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.70% 0.97 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 81.00 -15.25 1.00 -1.20 0.000 0.000 85.38 -15.98 1.00 -1.20 0.000 0.000 -4.66 -4.87 -5.41 Medium Trucks: Heavy Trucks: Autos: 70.20 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 42.412 42.203 42.223 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 71.5 69.6 67.8 62.2 71.270.6 65.6 69.2 64.0 56.3 56.8 65.164.9 67.2 57.8 63.0 70.270.1 Vehicle Noise:74.2 72.3 68.5 66.2 74.374.0 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 96 206 955443 100 216 1,004466 Tuesday, October 11, 2022 85 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:w/o Cherry Av. Road Name:Foothill Bl. (SR-66) Scenario:E 29,038 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,904 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 1.76 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -15.05 0.11 -1.20 0.000 0.000 86.40 -15.87 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 72.4 70.5 68.7 63.2 72.171.5 66.3 69.4 64.7 57.1 57.5 65.865.6 67.5 58.0 63.3 70.470.3 Vehicle Noise:74.8 72.9 69.3 66.8 74.974.6 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 133 287 1,334619 141 303 1,405652 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:w/o Cherry Av. Road Name:Foothill Bl. (SR-66) Scenario:E+P 29,077 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,908 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 1.76 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.32% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.67% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -15.04 0.11 -1.20 0.000 0.000 86.40 -15.84 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 72.4 70.5 68.7 63.2 72.171.6 66.3 69.5 64.8 57.1 57.5 65.865.6 67.5 58.1 63.3 70.470.4 Vehicle Noise:74.9 73.0 69.4 66.8 74.974.6 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 134 288 1,338621 141 303 1,409654 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:w/o Cherry Av. Road Name:Foothill Bl. (SR-66) Scenario:OY 33,692 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:3,369 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 2.40 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -14.40 0.11 -1.20 0.000 0.000 86.40 -15.22 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 73.1 71.1 69.4 63.8 72.872.2 66.9 70.1 65.4 57.7 58.1 66.466.3 68.1 58.7 63.9 71.171.0 Vehicle Noise:75.5 73.6 70.0 67.4 75.675.2 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 147 317 1,473684 155 334 1,552720 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:w/o Cherry Av. Road Name:Foothill Bl. (SR-66) Scenario:OY+P 33,730 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:3,373 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 2.41 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.32% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.67% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -14.40 0.11 -1.20 0.000 0.000 86.40 -15.20 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 73.1 71.1 69.4 63.8 72.872.2 66.9 70.1 65.4 57.7 58.1 66.466.3 68.1 58.7 63.9 71.171.0 Vehicle Noise:75.5 73.6 70.0 67.4 75.675.2 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 148 318 1,476685 155 335 1,555722 Tuesday, October 11, 2022 86 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:e/o Cherry Av. Road Name:Foothill Bl. (SR-66) Scenario:E 29,143 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,914 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 1.77 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -15.03 0.11 -1.20 0.000 0.000 86.40 -15.85 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 72.4 70.5 68.7 63.2 72.171.6 66.3 69.5 64.8 57.1 57.5 65.865.6 67.5 58.1 63.3 70.470.4 Vehicle Noise:74.9 73.0 69.4 66.8 74.974.6 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 134 288 1,338621 141 304 1,409654 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:e/o Cherry Av. Road Name:Foothill Bl. (SR-66) Scenario:E+P 29,328 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,933 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 1.79 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.12% 84.5%3.6%11.9%2.04% 76.1%2.2%21.7%1.84% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -14.94 0.11 -1.20 0.000 0.000 86.40 -15.39 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 72.5 70.5 68.8 63.2 72.271.6 66.4 69.9 64.9 57.2 57.6 65.965.7 67.9 58.5 63.8 70.970.8 Vehicle Noise:75.0 73.1 69.4 67.0 75.174.8 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 138 297 1,380640 145 313 1,451673 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:e/o Cherry Av. Road Name:Foothill Bl. (SR-66) Scenario:OY 37,778 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:3,778 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 2.90 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -13.90 0.11 -1.20 0.000 0.000 86.40 -14.73 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 73.6 71.6 69.9 64.3 73.372.7 67.4 70.6 65.9 58.2 58.6 66.966.8 68.6 59.2 64.4 71.671.5 Vehicle Noise:76.0 74.1 70.5 67.9 76.175.7 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 159 343 1,590738 167 361 1,675777 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:e/o Cherry Av. Road Name:Foothill Bl. (SR-66) Scenario:OY+P 37,963 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:3,796 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 2.91 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.17% 84.5%3.6%11.9%2.03% 76.1%2.2%21.7%1.80% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -13.84 0.11 -1.20 0.000 0.000 86.40 -14.36 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 73.6 71.6 69.9 64.3 73.372.7 67.5 70.9 66.0 58.3 58.7 67.066.8 69.0 59.5 64.8 71.971.9 Vehicle Noise:76.1 74.2 70.5 68.1 76.275.9 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 163 351 1,629756 171 369 1,713795 Tuesday, October 11, 2022 87 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:w/o Hemlock Av. Road Name:Foothill Bl. (SR-66) Scenario:E 25,529 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,553 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 1.20 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -15.61 0.11 -1.20 0.000 0.000 86.40 -16.43 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 71.9 69.9 68.2 62.6 71.671.0 65.7 68.9 64.2 56.5 56.9 65.265.1 66.9 57.5 62.7 69.969.8 Vehicle Noise:74.3 72.4 68.8 66.2 74.474.0 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 122 264 1,225568 129 278 1,290599 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:w/o Hemlock Av. Road Name:Foothill Bl. (SR-66) Scenario:E+P 25,731 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,573 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 1.22 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.09% 84.5%3.6%11.9%2.04% 76.1%2.2%21.7%1.87% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -15.51 0.11 -1.20 0.000 0.000 86.40 -15.90 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 71.9 69.9 68.2 62.6 71.671.0 65.8 69.4 64.3 56.6 57.0 65.365.2 67.4 58.0 63.2 70.470.3 Vehicle Noise:74.5 72.6 68.9 66.5 74.674.3 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 127 273 1,269589 133 287 1,334619 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:w/o Hemlock Av. Road Name:Foothill Bl. (SR-66) Scenario:OY 28,475 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,847 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 1.67 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -15.13 0.11 -1.20 0.000 0.000 86.40 -15.96 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 72.3 70.4 68.6 63.1 72.071.5 66.2 69.4 64.7 57.0 57.4 65.765.5 67.4 58.0 63.2 70.370.3 Vehicle Noise:74.8 72.9 69.3 66.7 74.874.5 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 132 284 1,317611 139 299 1,387644 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:w/o Hemlock Av. Road Name:Foothill Bl. (SR-66) Scenario:OY+P 28,677 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,868 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 1.69 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.12% 84.5%3.6%11.9%2.04% 76.1%2.2%21.7%1.84% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -15.04 0.11 -1.20 0.000 0.000 86.40 -15.48 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 72.4 70.4 68.7 63.1 72.171.5 66.3 69.8 64.8 57.1 57.5 65.865.6 67.9 58.4 63.7 70.870.7 Vehicle Noise:74.9 73.0 69.3 66.9 75.074.7 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 136 293 1,360631 143 308 1,430664 Tuesday, October 11, 2022 88 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:e/o Hemlock Av. Road Name:Foothill Bl. (SR-66) Scenario:E 26,742 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,674 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 1.40 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -15.41 0.11 -1.20 0.000 0.000 86.40 -16.23 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 72.1 70.1 68.4 62.8 71.871.2 65.9 69.1 64.4 56.7 57.1 65.465.3 67.1 57.7 62.9 70.170.0 Vehicle Noise:74.5 72.6 69.0 66.4 74.674.2 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 126 272 1,263586 133 287 1,330617 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:e/o Hemlock Av. Road Name:Foothill Bl. (SR-66) Scenario:E+P 26,961 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,696 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 1.43 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.11% 84.5%3.6%11.9%2.04% 76.1%2.2%21.7%1.85% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -15.31 0.11 -1.20 0.000 0.000 86.40 -15.72 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 72.1 70.1 68.4 62.8 71.871.2 66.0 69.6 64.5 56.8 57.2 65.565.4 67.6 58.2 63.4 70.670.5 Vehicle Noise:74.7 72.8 69.1 66.7 74.874.5 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 131 282 1,307607 137 296 1,374638 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:e/o Hemlock Av. Road Name:Foothill Bl. (SR-66) Scenario:OY 31,783 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:3,178 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 2.15 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -14.66 0.11 -1.20 0.000 0.000 86.40 -15.48 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 72.8 70.9 69.1 63.5 72.571.9 66.7 69.8 65.1 57.5 57.9 66.266.0 67.9 58.4 63.7 70.870.7 Vehicle Noise:75.2 73.3 69.7 67.2 75.375.0 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 142 305 1,417658 149 322 1,493693 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:e/o Hemlock Av. Road Name:Foothill Bl. (SR-66) Scenario:OY+P 32,002 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:3,200 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 2.17 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.14% 84.5%3.6%11.9%2.03% 76.1%2.2%21.7%1.82% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -14.57 0.11 -1.20 0.000 0.000 86.40 -15.05 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 72.8 70.9 69.1 63.6 72.572.0 66.7 70.3 65.2 57.5 57.9 66.366.1 68.3 58.9 64.1 71.271.2 Vehicle Noise:75.4 73.5 69.8 67.4 75.575.2 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 146 314 1,459677 153 331 1,534712 Tuesday, October 11, 2022 89 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:e/o Beech Av. Road Name:Foothill Bl. (SR-66) Scenario:E 25,908 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,591 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 1.26 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -15.54 0.11 -1.20 0.000 0.000 86.40 -16.37 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 71.9 70.0 68.2 62.7 71.671.0 65.8 68.9 64.3 56.6 57.0 65.365.1 67.0 57.5 62.8 69.969.8 Vehicle Noise:74.4 72.5 68.8 66.3 74.474.1 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 124 266 1,237574 130 281 1,302605 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:e/o Beech Av. Road Name:Foothill Bl. (SR-66) Scenario:E+P 26,115 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,611 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 1.29 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.27% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.72% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -15.51 0.11 -1.20 0.000 0.000 86.40 -16.18 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 72.0 70.0 68.3 62.7 71.771.1 65.8 69.1 64.3 56.6 57.0 65.365.2 67.1 57.7 63.0 70.170.0 Vehicle Noise:74.4 72.5 68.9 66.4 74.574.2 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 125 270 1,254582 132 284 1,320613 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:e/o Beech Av. Road Name:Foothill Bl. (SR-66) Scenario:OY 31,300 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:3,130 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 2.08 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -14.72 0.11 -1.20 0.000 0.000 86.40 -15.54 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 72.8 70.8 69.0 63.5 72.471.9 66.6 69.8 65.1 57.4 57.8 66.166.0 67.8 58.4 63.6 70.770.7 Vehicle Noise:75.2 73.3 69.7 67.1 75.274.9 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 140 302 1,403651 148 318 1,477686 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:e/o Beech Av. Road Name:Foothill Bl. (SR-66) Scenario:OY+P 31,300 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:3,130 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 2.08 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -14.72 0.11 -1.20 0.000 0.000 86.40 -15.54 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 72.8 70.8 69.0 63.5 72.471.9 66.6 69.8 65.1 57.4 57.8 66.166.0 67.8 58.4 63.6 70.770.7 Vehicle Noise:75.2 73.3 69.7 67.1 75.274.9 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 140 302 1,403651 148 318 1,477686 Tuesday, October 11, 2022 90 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:w/o Citrus Av. Road Name:Foothill Bl. (SR-66) Scenario:E 26,377 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,638 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 1.34 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -15.46 0.11 -1.20 0.000 0.000 86.40 -16.29 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 72.0 70.1 68.3 62.7 71.771.1 65.9 69.0 64.3 56.6 57.1 65.465.2 67.0 57.6 62.9 70.069.9 Vehicle Noise:74.4 72.5 68.9 66.3 74.574.2 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 125 270 1,252581 132 284 1,318612 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:w/o Citrus Av. Road Name:Foothill Bl. (SR-66) Scenario:E+P 26,551 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,655 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 1.37 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.27% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.72% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -15.43 0.11 -1.20 0.000 0.000 86.40 -16.11 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 72.0 70.1 68.3 62.8 71.771.2 65.9 69.2 64.4 56.7 57.1 65.465.2 67.2 57.8 63.0 70.270.1 Vehicle Noise:74.5 72.6 69.0 66.4 74.674.3 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 127 273 1,268589 133 288 1,335620 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:w/o Citrus Av. Road Name:Foothill Bl. (SR-66) Scenario:OY 32,059 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:3,206 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 2.19 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -14.62 0.11 -1.20 0.000 0.000 86.40 -15.44 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 72.9 70.9 69.2 63.6 72.572.0 66.7 69.9 65.2 57.5 57.9 66.266.1 67.9 58.5 63.7 70.870.8 Vehicle Noise:75.3 73.4 69.8 67.2 75.475.0 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 143 307 1,425662 150 323 1,501697 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:w/o Citrus Av. Road Name:Foothill Bl. (SR-66) Scenario:OY+P 32,059 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:3,206 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 2.19 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -14.62 0.11 -1.20 0.000 0.000 86.40 -15.44 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 72.9 70.9 69.2 63.6 72.572.0 66.7 69.9 65.2 57.5 57.9 66.266.1 67.9 58.5 63.7 70.870.8 Vehicle Noise:75.3 73.4 69.8 67.2 75.475.0 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 143 307 1,425662 150 323 1,501697 Tuesday, October 11, 2022 91 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:e/o Citrus Av. Road Name:Foothill Bl. (SR-66) Scenario:E 25,973 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,597 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 1.27 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -15.53 0.11 -1.20 0.000 0.000 86.40 -16.35 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 71.9 70.0 68.2 62.7 71.671.1 65.8 69.0 64.3 56.6 57.0 65.365.1 67.0 57.6 62.8 69.969.9 Vehicle Noise:74.4 72.5 68.9 66.3 74.474.1 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 124 267 1,239575 130 281 1,305606 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:e/o Citrus Av. Road Name:Foothill Bl. (SR-66) Scenario:E+P 26,006 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:2,601 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 1.28 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -15.53 0.11 -1.20 0.000 0.000 86.40 -16.35 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 72.0 70.0 68.2 62.7 71.671.1 65.8 69.0 64.3 56.6 57.0 65.365.1 67.0 57.6 62.8 69.969.9 Vehicle Noise:74.4 72.5 68.9 66.3 74.474.1 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 124 267 1,239575 131 281 1,305606 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:e/o Citrus Av. Road Name:Foothill Bl. (SR-66) Scenario:OY 30,922 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:3,092 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 2.03 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -14.77 0.11 -1.20 0.000 0.000 86.40 -15.60 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 72.7 70.8 69.0 63.4 72.471.8 66.5 69.7 65.0 57.3 57.7 66.165.9 67.7 58.3 63.5 70.770.6 Vehicle Noise:75.1 73.2 69.6 67.0 75.274.9 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 139 300 1,391646 147 316 1,466680 Tuesday, October 11, 2022 FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021) SITE SPECIFIC INPUT DATA Project Name:Beech Logistics Center Job Number:14726 Road Segment:e/o Citrus Av. Road Name:Foothill Bl. (SR-66) Scenario:OY+P 30,922 10.00% 66.0 NOISE MODEL INPUTS Average Daily Traffic (Adt): Peak Hour Percentage: Peak Hour Volume:3,092 vehicles Centerline Dist. to Barrier: 66.0Centerline Dist. to Observer: Highway Data feet feet vehicles Road Elevation:0.0 Road Grade:0.0% Pad Elevation:0.0 Site Data Site Conditions (Hard = 10, Soft = 15) Medium Trucks (2 Axles):15 Heavy Trucks (3+ Axles):15 Autos:15 Vehicle Mix feet feet Lane Equivalent Distance (in feet) Barrier Height:0.0 Observer Height (Above Pad):5.0 feet feet 55 mphVehicle Speed: Near/Far Lane Distance:90 feet REMEL Traffic Flow Distance 2.03 VehicleType Day Evening Night Daily Medium Trucks: Heavy Trucks: Autos:76.6%12.8%10.6%96.33% 84.5%3.6%11.9%2.01% 76.1%2.2%21.7%1.66% 0.09 Finite Road -1.20 Left View:-90.0 Right View:90.0 degrees degrees Barrier Atten FHWA Noise Model Calculations 0.0Barrier Distance to Observer:feet Barrier Type (0-Wall, 1-Berm):0.0 0.000 0.000 Fresnel Berm Atten Medium Trucks: Heavy Trucks: Autos: VehicleType 82.40 -14.77 0.11 -1.20 0.000 0.000 86.40 -15.60 0.11 -1.20 0.000 0.000 -4.71 -4.88 -5.30 Medium Trucks: Heavy Trucks: Autos: 71.78 Noise Source Elevations (in feet) Medium Trucks: Heavy Trucks: Autos:0.000 2.297 8.004 48.539 48.356 48.374 Grade Adjustment:0.0 Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks: Heavy Trucks: Autos: VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night CNELLdn 72.7 70.8 69.0 63.4 72.471.8 66.5 69.7 65.0 57.3 57.7 66.165.9 67.7 58.3 63.5 70.770.6 Vehicle Noise:75.1 73.2 69.6 67.0 75.274.9 Centerline Distance to Noise Contour (in feet) CNEL: Ldn: 70 dBA 65 dBA 55 dBA60 dBA 139 300 1,391646 147 316 1,466680 Tuesday, October 11, 2022 92 Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study APPENDIX 9.1: CADNAA OPERATIONAL NOISE MODEL INPUTS 93 Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study This page intentionally left blank 94 14726 - Beech Logistics Center CadnaA Noise Prediction Model: 14726-02.cna Date: 11.10.22 Analyst: B. Lawson Calculation Configuration Configuration Parameter Value General Max. Error (dB)0.00 Max. Search Radius (#(Unit,LEN))2000.01 Min. Dist Src to Rcvr 0.00 Partition Raster Factor 0.50 Max. Length of Section (#(Unit,LEN))999.99 Min. Length of Section (#(Unit,LEN))1.01 Min. Length of Section (%)0.00 Proj. Line Sources On Proj. Area Sources On Ref. Time Reference Time Day (min)960.00 Reference Time Night (min)480.00 Daytime Penalty (dB)0.00 Recr. Time Penalty (dB)5.00 Night-time Penalty (dB)10.00 DTM Standard Height (m)0.00 Model of Terrain Triangulation Reflection max. Order of Reflection 2 Search Radius Src 100.00 Search Radius Rcvr 100.00 Max. Distance Source - Rcvr 1000.00 1000.00 Min. Distance Rvcr - Reflector 1.00 1.00 Min. Distance Source - Reflector 0.10 Industrial (ISO 9613) Lateral Diffraction some Obj Obst. within Area Src do not shield On Screening Incl. Ground Att. over Barrier Dz with limit (20/25) Barrier Coefficients C1,2,3 3.0 20.0 0.0 Temperature (#(Unit,TEMP))10 rel. Humidity (%)70 Ground Absorption G 0.50 Wind Speed for Dir. (#(Unit,SPEED))3.0 Roads (TNM) Railways (FTA/FRA) Aircraft (???) Strictly acc. to AzB Receiver Noise Levels Name M.ID Level Lr Limit. Value Land Use Height Coordinates Day Night CNEL Day Night CNEL Type Auto Noise Type X Y Z (dBA)(dBA)(dBA)(dBA)(dBA)(dBA)(ft)(ft)(ft)(ft) RECEIVERS R1 49.2 49.2 55.8 70.0 65.0 0.0 5.00 a 6191630.52 2349847.42 5.00 RECEIVERS R2 53.0 53.0 59.7 70.0 65.0 0.0 5.00 a 6192072.27 2349581.19 5.00 RECEIVERS R3 45.8 45.7 52.4 70.0 65.0 0.0 5.00 a 6192712.16 2349223.03 5.00 RECEIVERS R4 44.5 44.5 51.2 70.0 65.0 0.0 5.00 a 6192344.81 2348348.88 5.00 RECEIVERS R5 45.3 45.3 52.0 70.0 65.0 0.0 5.00 a 6191642.59 2348355.13 5.00 RECEIVERS R6 44.0 43.9 50.5 70.0 65.0 0.0 5.00 a 6191411.34 2348765.52 5.00 Point Source(s) Name M.ID Result. PWL Lw / Li Operating Time Height Coordinates Day Evening Night Type Value norm.Day Special Night X Y Z (dBA)(dBA)(dBA)dB(A)(min)(min)(min)(ft)(ft)(ft)(ft) POINTSOURCE AC01 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6191726.32 2349219.08 50.00 POINTSOURCE AC02 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6191697.58 2349190.71 50.00 POINTSOURCE TRASH01 89.0 89.0 89.0 Lw 89 5.00 a 6191827.70 2349595.53 5.00 POINTSOURCE CAR01 81.1 81.1 81.1 Lw 81.1 5.00 a 6191602.12 2349694.96 5.00 POINTSOURCE CAR02 81.1 81.1 81.1 Lw 81.1 5.00 a 6191569.87 2349743.00 5.00 POINTSOURCE CAR03 81.1 81.1 81.1 Lw 81.1 5.00 a 6191547.43 2349695.89 5.00 POINTSOURCE CAR04 81.1 81.1 81.1 Lw 81.1 5.00 a 6191509.77 2349744.02 5.00 POINTSOURCE CAR05 81.1 81.1 81.1 Lw 81.1 5.00 a 6191484.91 2349696.35 5.00 POINTSOURCE CAR06 81.1 81.1 81.1 Lw 81.1 5.00 a 6191460.47 2349744.26 5.00 POINTSOURCE CAR07 81.1 81.1 81.1 Lw 81.1 5.00 a 6191417.59 2349697.49 5.00 POINTSOURCE CAR08 81.1 81.1 81.1 Lw 81.1 5.00 a 6191393.15 2349745.40 5.00 POINTSOURCE CAR09 81.1 81.1 81.1 Lw 81.1 5.00 a 6191356.65 2349118.33 5.00 Urban Crossroads, Inc.95 Name M.ID Result. PWL Lw / Li Operating Time Height Coordinates Day Evening Night Type Value norm.Day Special Night X Y Z (dBA)(dBA)(dBA)dB(A)(min)(min)(min)(ft)(ft)(ft)(ft) POINTSOURCE CAR10 81.1 81.1 81.1 Lw 81.1 5.00 a 6191401.70 2349115.77 5.00 POINTSOURCE CAR11 81.1 81.1 81.1 Lw 81.1 5.00 a 6191404.94 2349165.01 5.00 POINTSOURCE CAR12 81.1 81.1 81.1 Lw 81.1 5.00 a 6191452.78 2349114.30 5.00 POINTSOURCE CAR13 81.1 81.1 81.1 Lw 81.1 5.00 a 6191475.25 2349162.62 5.00 POINTSOURCE CAR14 81.1 81.1 81.1 Lw 81.1 5.00 a 6191497.89 2349115.34 5.00 POINTSOURCE CAR15 81.1 81.1 81.1 Lw 81.1 5.00 a 6191549.17 2349160.76 5.00 POINTSOURCE CAR16 81.1 81.1 81.1 Lw 81.1 5.00 a 6191567.05 2349116.57 5.00 POINTSOURCE CAR17 81.1 81.1 81.1 Lw 81.1 5.00 a 6191594.26 2349160.60 5.00 POINTSOURCE CAR18 81.1 81.1 81.1 Lw 81.1 5.00 a 6191609.72 2349115.24 5.00 POINTSOURCE CAR19 81.1 81.1 81.1 Lw 81.1 5.00 a 6191647.16 2349160.30 5.00 POINTSOURCE CAR20 81.1 81.1 81.1 Lw 81.1 5.00 a 6191662.00 2349113.75 5.00 POINTSOURCE CAR21 81.1 81.1 81.1 Lw 81.1 5.00 a 6191684.41 2349159.07 5.00 POINTSOURCE CAR22 81.1 81.1 81.1 Lw 81.1 5.00 a 6191701.67 2349113.08 5.00 POINTSOURCE CAR23 81.1 81.1 81.1 Lw 81.1 5.00 a 6191721.07 2349157.84 5.00 POINTSOURCE CAR24 81.1 81.1 81.1 Lw 81.1 5.00 a 6191744.94 2349111.74 5.00 POINTSOURCE CAR25 81.1 81.1 81.1 Lw 81.1 5.00 a 6191779.20 2349111.16 5.00 Line Source(s) Name M.ID Result. PWL Result. PWL'Lw / Li Operating Time Moving Pt. Src Height Day Evening Night Day Evening Night Type Value norm.Day Special Night Number Speed (dBA)(dBA)(dBA)(dBA)(dBA)(dBA)dB(A)(min)(min)(min)Day Evening Night (mph)(ft) LINESOURCE TRUCK01 93.2 93.2 93.2 77.2 77.2 77.2 Lw 93.2 8 a LINESOURCE TRUCK02 93.2 93.2 93.2 74.7 74.7 74.7 Lw 93.2 8 a Name Height Coordinates Begin End x y z Ground (ft)(ft)(ft)(ft)(ft)(ft) LINESOURCE 8.00 a 6191945.81 2349502.13 8.00 0.00 6191815.47 2349503.75 8.00 0.00 LINESOURCE 8.00 a 6191783.06 2349233.89 8.00 0.00 6191781.90 2349175.50 8.00 0.00 6191784.70 2349167.90 8.00 0.00 6191788.76 2349160.89 8.00 0.00 6191793.97 2349154.68 8.00 0.00 6191800.16 2349149.46 8.00 0.00 6191807.15 2349145.37 8.00 0.00 6191814.74 2349142.54 8.00 0.00 6191822.71 2349141.05 8.00 0.00 6191830.81 2349140.95 8.00 0.00 6191937.58 2349139.12 8.00 0.00 Area Source(s) Name M.ID Result. PWL Result. PWL''Lw / Li Operating Time Height Day Evening Night Day Evening Night Type Value norm.Day Special Night (ft) (dBA)(dBA)(dBA)(dBA)(dBA)(dBA)dB(A)(min)(min)(min) AREASOURCE DOCK01 111.5 111.5 111.5 72.9 72.9 72.9 Lw 111.5 8 a Name Height Coordinates Begin End x y z Ground (ft)(ft)(ft)(ft)(ft)(ft) AREASOURCE 8.00 a 6191692.93 2349619.50 8.00 0.00 6191806.49 2349619.13 8.00 0.00 6191917.86 2349551.08 8.00 0.00 6191919.55 2349528.13 8.00 0.00 6191815.92 2349530.41 8.00 0.00 6191815.00 2349476.25 8.00 0.00 6191917.61 2349475.03 8.00 0.00 6191911.93 2349232.89 8.00 0.00 6191685.35 2349234.65 8.00 0.00 Barrier(s) Name M.ID Absorption Z-Ext.Cantilever Height Coordinates left right horz.vert.Begin End x y z Ground (ft)(ft)(ft)(ft)(ft)(ft)(ft)(ft)(ft) BARRIEREXISTING 0 6.00 a 6191953.06 2349635.26 6.00 0.00 6191149.54 2350122.95 6.00 0.00 BARRIEREXISTING 0 6.00 a 6192140.49 2349628.60 6.00 0.00 6192068.43 2349628.96 6.00 0.00 6192075.81 2350115.04 6.00 0.00 BARRIEREXISTING 0 6.00 a 6192272.26 2349514.36 6.00 0.00 6192247.00 2349509.58 6.00 0.00 6192261.96 2349470.26 6.00 0.00 6192313.55 2349440.73 6.00 0.00 6192471.57 2349440.65 6.00 0.00 Urban Crossroads, Inc.96 Name M.ID Absorption Z-Ext.Cantilever Height Coordinates left right horz.vert.Begin End x y z Ground (ft)(ft)(ft)(ft)(ft)(ft)(ft)(ft)(ft) 6192519.63 2349407.71 6.00 0.00 6192624.70 2349408.53 6.00 0.00 BARRIERTEMP 0 14.00 a 6191665.53 2349711.32 14.00 0.00 6191922.00 2349554.25 14.00 0.00 6191921.80 2349517.33 14.00 0.00 6191843.15 2349518.49 14.00 0.00 BARRIERTEMP 0 14.00 a 6191842.63 2349487.41 14.00 0.00 6191920.93 2349486.43 14.00 0.00 6191915.00 2349229.36 14.00 0.00 6191802.85 2349231.09 14.00 0.00 BARRIERTEMP 0 14.00 a 6191763.26 2349231.24 14.00 0.00 6191739.48 2349231.47 14.00 0.00 Building(s) Name M.ID RB Residents Absorption Height Coordinates Begin x y z Ground (ft)(ft)(ft)(ft)(ft) BUILDING BUILDING00001 x 0 45.00 a 6191388.45 2349681.15 45.00 0.00 6191651.14 2349677.89 45.00 0.00 6191692.22 2349654.35 45.00 0.00 6191683.27 2349233.04 45.00 0.00 6191739.13 2349230.29 45.00 0.00 6191738.84 2349177.38 45.00 0.00 6191377.59 2349182.91 45.00 0.00 Urban Crossroads, Inc.97 Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study This page intentionally left blank 98 Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study APPENDIX 10.1: CADNAA CONSTRUCTION NOISE MODEL INPUTS 99 Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study This page intentionally left blank 100 14726 - Beech Logistics Center CadnaA Noise Prediction Model: 14726-02_Construction.cna Date: 11.10.22 Analyst: B. Lawson Calculation Configuration Configuration Parameter Value General Max. Error (dB)0.00 Max. Search Radius (#(Unit,LEN))2000.01 Min. Dist Src to Rcvr 0.00 Partition Raster Factor 0.50 Max. Length of Section (#(Unit,LEN))999.99 Min. Length of Section (#(Unit,LEN))1.01 Min. Length of Section (%)0.00 Proj. Line Sources On Proj. Area Sources On Ref. Time Reference Time Day (min)960.00 Reference Time Night (min)480.00 Daytime Penalty (dB)0.00 Recr. Time Penalty (dB)5.00 Night-time Penalty (dB)10.00 DTM Standard Height (m)0.00 Model of Terrain Triangulation Reflection max. Order of Reflection 2 Search Radius Src 100.00 Search Radius Rcvr 100.00 Max. Distance Source - Rcvr 1000.00 1000.00 Min. Distance Rvcr - Reflector 1.00 1.00 Min. Distance Source - Reflector 0.10 Industrial (ISO 9613) Lateral Diffraction some Obj Obst. within Area Src do not shield On Screening Incl. Ground Att. over Barrier Dz with limit (20/25) Barrier Coefficients C1,2,3 3.0 20.0 0.0 Temperature (#(Unit,TEMP))10 rel. Humidity (%)70 Ground Absorption G 0.50 Wind Speed for Dir. (#(Unit,SPEED))3.0 Roads (TNM) Railways (FTA/FRA) Aircraft (???) Strictly acc. to AzB Receiver Noise Levels Name M.ID Level Lr Limit. Value Land Use Height Coordinates Day Night CNEL Day Night CNEL Type Auto Noise Type X Y Z (dBA)(dBA)(dBA)(dBA)(dBA)(dBA)(ft)(ft)(ft)(ft) RECEIVERS R1 62.2 -42.6 59.2 70.0 65.0 0.0 5.00 a 6191630.52 2349847.42 5.00 RECEIVERS R2 65.5 -39.3 62.4 70.0 65.0 0.0 5.00 a 6192072.27 2349581.19 5.00 RECEIVERS R3 57.4 -47.4 54.4 70.0 65.0 0.0 5.00 a 6192712.16 2349223.03 5.00 RECEIVERS R4 56.1 -48.7 53.0 70.0 65.0 0.0 5.00 a 6192344.81 2348348.88 5.00 RECEIVERS R5 57.9 -46.9 54.9 70.0 65.0 0.0 5.00 a 6191642.59 2348355.13 5.00 RECEIVERS R6 62.0 -42.8 59.0 70.0 65.0 0.0 5.00 a 6191411.34 2348765.52 5.00 Area Source(s) Name M.ID Result. PWL Result. PWL''Lw / Li Operating Time Height Day Evening Night Day Evening Night Type Value norm.Day Special Night (ft) (dBA)(dBA)(dBA)(dBA)(dBA)(dBA)dB(A)(min)(min)(min) SITEBOUNDARY CONSTRUCTION 119.8 15.0 15.0 74.5 -30.2 -30.2 PWL-Pt 115 8 a Name Height Coordinates Begin End x y z Ground (ft)(ft)(ft)(ft)(ft)(ft) SITEBOUNDARY 8.00 a 6191335.51 2349099.39 8.00 0.00 6191348.38 2349759.65 8.00 0.00 6191601.82 2349755.86 8.00 0.00 6191946.79 2349545.55 8.00 0.00 6191936.61 2349096.64 8.00 0.00 Urban Crossroads, Inc.101 Barrier(s) Name M.ID Absorption Z-Ext.Cantilever Height Coordinates left right horz.vert.Begin End x y z Ground (ft)(ft)(ft)(ft)(ft)(ft)(ft)(ft)(ft) BARRIEREXISTING 0 6.00 a 6191953.06 2349635.26 6.00 0.00 6191149.54 2350122.95 6.00 0.00 BARRIEREXISTING 0 6.00 a 6192140.49 2349628.60 6.00 0.00 6192068.43 2349628.96 6.00 0.00 6192075.81 2350115.04 6.00 0.00 BARRIEREXISTING 0 6.00 a 6192272.26 2349514.36 6.00 0.00 6192247.00 2349509.58 6.00 0.00 6192261.96 2349470.26 6.00 0.00 6192313.55 2349440.73 6.00 0.00 6192471.57 2349440.65 6.00 0.00 6192519.63 2349407.71 6.00 0.00 6192624.70 2349408.53 6.00 0.00 Urban Crossroads, Inc.102 Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study APPENDIX 10.2: CADNAA CONCRETE POUR NOISE MODEL INPUTS 103 Beech Logistics Center Noise and Vibration Analysis 14726-03 Noise Study This page intentionally left blank 104 14726 - Beech Logistics Center CadnaA Noise Prediction Model: 14726-02_Concrete.cna Date: 11.10.22 Analyst: B. Lawson Calculation Configuration Configuration Parameter Value General Max. Error (dB)0.00 Max. Search Radius (#(Unit,LEN))2000.01 Min. Dist Src to Rcvr 0.00 Partition Raster Factor 0.50 Max. Length of Section (#(Unit,LEN))999.99 Min. Length of Section (#(Unit,LEN))1.01 Min. Length of Section (%)0.00 Proj. Line Sources On Proj. Area Sources On Ref. Time Reference Time Day (min)960.00 Reference Time Night (min)480.00 Daytime Penalty (dB)0.00 Recr. Time Penalty (dB)5.00 Night-time Penalty (dB)10.00 DTM Standard Height (m)0.00 Model of Terrain Triangulation Reflection max. Order of Reflection 2 Search Radius Src 100.00 Search Radius Rcvr 100.00 Max. Distance Source - Rcvr 1000.00 1000.00 Min. Distance Rvcr - Reflector 1.00 1.00 Min. Distance Source - Reflector 0.10 Industrial (ISO 9613) Lateral Diffraction some Obj Obst. within Area Src do not shield On Screening Incl. Ground Att. over Barrier Dz with limit (20/25) Barrier Coefficients C1,2,3 3.0 20.0 0.0 Temperature (#(Unit,TEMP))10 rel. Humidity (%)70 Ground Absorption G 0.50 Wind Speed for Dir. (#(Unit,SPEED))3.0 Roads (TNM) Railways (FTA/FRA) Aircraft (???) Strictly acc. to AzB Receiver Noise Levels Name M.ID Level Lr Limit. Value Land Use Height Coordinates Day Night CNEL Day Night CNEL Type Auto Noise Type X Y Z (dBA)(dBA)(dBA)(dBA)(dBA)(dBA)(ft)(ft)(ft)(ft) RECEIVERS R1 47.0 -57.7 44.0 70.0 65.0 0.0 5.00 a 6191630.52 2349847.42 5.00 RECEIVERS R2 48.8 -55.9 45.8 70.0 65.0 0.0 5.00 a 6192072.27 2349581.19 5.00 RECEIVERS R3 42.0 -62.7 39.0 70.0 65.0 0.0 5.00 a 6192712.16 2349223.03 5.00 RECEIVERS R4 40.8 -63.8 37.8 70.0 65.0 0.0 5.00 a 6192344.81 2348348.88 5.00 RECEIVERS R5 42.9 -61.8 39.9 70.0 65.0 0.0 5.00 a 6191642.59 2348355.13 5.00 RECEIVERS R6 47.1 -57.6 44.1 70.0 65.0 0.0 5.00 a 6191411.34 2348765.52 5.00 Area Source(s) Name M.ID Result. PWL Result. PWL''Lw / Li Operating Time Height Day Evening Night Day Evening Night Type Value norm.Day Special Night (ft) (dBA)(dBA)(dBA)(dBA)(dBA)(dBA)dB(A)(min)(min)(min) CONCRETE CONCRETE POUR 105.1 0.3 0.3 62.9 -41.8 -41.8 PWL-Pt 100.3 8 a Name Height Coordinates Begin End x y z Ground (ft)(ft)(ft)(ft)(ft)(ft) CONCRETE 8.00 a 6191388.92 2349680.54 8.00 0.00 6191650.93 2349679.00 8.00 0.00 6191692.92 2349653.88 8.00 0.00 6191691.94 2349595.80 8.00 0.00 6191750.60 2349594.80 8.00 0.00 6191738.29 2349177.25 8.00 0.00 6191377.53 2349181.05 8.00 0.00 Urban Crossroads, Inc.105 Barrier(s) Name M.ID Absorption Z-Ext.Cantilever Height Coordinates left right horz.vert.Begin End x y z Ground (ft)(ft)(ft)(ft)(ft)(ft)(ft)(ft)(ft) BARRIEREXISTING 0 6.00 a 6191953.06 2349635.26 6.00 0.00 6191149.54 2350122.95 6.00 0.00 BARRIEREXISTING 0 6.00 a 6192140.49 2349628.60 6.00 0.00 6192068.43 2349628.96 6.00 0.00 6192075.81 2350115.04 6.00 0.00 BARRIEREXISTING 0 6.00 a 6192272.26 2349514.36 6.00 0.00 6192247.00 2349509.58 6.00 0.00 6192261.96 2349470.26 6.00 0.00 6192313.55 2349440.73 6.00 0.00 6192471.57 2349440.65 6.00 0.00 6192519.63 2349407.71 6.00 0.00 6192624.70 2349408.53 6.00 0.00 Urban Crossroads, Inc.106