Loading...
HomeMy WebLinkAboutAppendix F - Noise AssessmentAPPENDIX F-1 Field Noise Data Sheets ST1 Rec 208 to 223 Slow Response dBA weighting 2.0 dB resolution stats Date hh:mm:ss LeqPeriod Leq SEL Lmax Lmin 2/22/2022 12:29 1.0 min 58.8 76.6 68.8 49 2/22/2022 12:30 1.0 min 64.7 82.5 72.8 52.1 2/22/2022 12:31 1.0 min 68.6 86.4 74.2 53.4 2/22/2022 12:32 1.0 min 60.4 78.2 73.7 48.7 2/22/2022 12:33 1.0 min 57.2 75 62.8 51.9 2/22/2022 12:34 1.0 min 69 86.8 75 57.3 2/22/2022 12:35 1.0 min 67.3 85.1 76.1 54.1 2/22/2022 12:36 1.0 min 60.5 78.3 69 54.2 2/22/2022 12:37 1.0 min 64.6 82.4 76 51.6 2/22/2022 12:38 1.0 min 69.7 87.5 76.3 57.8 2/22/2022 12:39 1.0 min 52.5 70.3 57.8 49.5 2/22/2022 12:40 1.0 min 60.1 77.9 69.3 50.6 2/22/2022 12:41 1.0 min 60 77.8 69.3 51.6 2/22/2022 12:42 1.0 min 62.2 80 71.3 52.3 2/22/2022 12:43 1.0 min 62.3 80.1 73 53.5 2/22/2022 12:44 8 sec 55.5 64.5 56.9 54.2 Leq Lmax Lmin 64.8 76.3 48.7 ST2 Rec 224 to 239 Slow Response dBA weighting 2.0 dB resolution stats Date hh:mm:ss LeqPeriod Leq SEL Lmax Lmin 2/22/2022 12:56 1.0 min 64.3 82.1 76.1 52.5 2/22/2022 12:57 1.0 min 62.2 80 73.4 51.8 2/22/2022 12:58 1.0 min 65.6 83.4 76.8 49.9 2/22/2022 12:59 1.0 min 64.4 82.2 73 51.3 2/22/2022 13:00 1.0 min 57.3 75.1 68.2 49.4 2/22/2022 13:01 1.0 min 67.3 85.1 79.2 50.1 2/22/2022 13:02 1.0 min 67.8 85.6 77 51.7 2/22/2022 13:03 1.0 min 65.8 83.6 73.7 51.9 2/22/2022 13:04 1.0 min 63.9 81.7 73.7 51.6 2/22/2022 13:05 1.0 min 58.6 76.4 68.2 50.8 2/22/2022 13:06 1.0 min 55.9 73.7 69.1 49.4 2/22/2022 13:07 1.0 min 66.7 84.5 80.2 50.4 2/22/2022 13:08 1.0 min 64.2 82 75.8 54.3 2/22/2022 13:09 1.0 min 66.4 84.2 74.9 55.1 2/22/2022 13:10 1.0 min 61.4 79.2 72.5 51.4 2/22/2022 13:11 8 sec 71.3 80.3 76.5 57.9 Leq Lmax Lmin 64.6 80.2 49.4 ST3 Rec 240 to 255 Slow Response dBA weighting 2.0 dB resolution stats Date hh:mm:ss LeqPeriod Leq SEL Lmax Lmin 2/22/2022 13:18 1.0 min 63.9 81.7 70.7 56.2 2/22/2022 13:19 1.0 min 70.7 88.5 84 55.5 2/22/2022 13:20 1.0 min 62.4 80.2 73 52.8 2/22/2022 13:21 1.0 min 62 79.8 70.9 51.9 2/22/2022 13:22 1.0 min 66.3 84.1 73.9 54.8 2/22/2022 13:23 1.0 min 66.1 83.9 72.3 62.7 2/22/2022 13:24 1.0 min 68.5 86.3 75.5 62.6 2/22/2022 13:25 1.0 min 67.4 85.2 75.6 59.5 2/22/2022 13:26 1.0 min 66.6 84.4 77.7 56.6 2/22/2022 13:27 1.0 min 63.4 81.2 72.9 51.3 2/22/2022 13:28 1.0 min 58 75.8 69.9 49.5 2/22/2022 13:29 1.0 min 64.1 81.9 71.3 55 2/22/2022 13:30 1.0 min 67.3 85.1 71.7 59.9 2/22/2022 13:31 1.0 min 67.4 85.2 75.1 63.9 2/22/2022 13:32 1.0 min 66.4 84.2 74.1 63.8 2/22/2022 13:33 10 sec 70.5 80.5 74.7 66.2 Leq Lmax Lmin 66.3 84 49.5 LT1 Rec 1 to 98 Slow Response dBA weighting 2.0 dB resolution stats Date hh:mm:ss LeqPeriod Leq SEL Lmax Lmin L1%L5%L10%L50%L90%L95%L99%Lmedian Lmean 11/19/2019 11:02 15.0 min 70.8 100.3 86.1 44.7 82 78 74 60 52 48 46 60 61.3 11/19/2019 11:17 15.0 min 68.3 97.8 84.4 44.6 80 74 72 54 46 46 44 54 56.9 11/19/2019 11:32 15.0 min 68.3 97.8 83.6 45.7 78 74 72 56 48 46 46 56 58.2 11/19/2019 11:47 15.0 min 69.1 98.6 84.9 47.2 80 76 72 54 48 48 48 54 57.9 11/19/2019 12:02 15.0 min 69.7 99.2 87.9 46.7 82 74 72 58 50 48 46 58 59.1 11/19/2019 12:17 15.0 min 67.6 97.1 82.7 46.2 78 74 70 54 48 46 46 54 57.1 11/19/2019 12:32 15.0 min 70 99.5 87.2 49.2 80 76 74 60 50 50 50 60 60.7 11/19/2019 12:47 15.0 min 71.5 101 94.9 49.3 80 76 74 58 50 50 50 58 59.9 11/19/2019 13:02 15.0 min 69 98.5 86.2 49.7 80 74 70 56 50 50 50 56 58.5 11/19/2019 13:17 15.0 min 70.5 100 87.9 50.5 82 76 72 60 52 52 50 60 61.4 11/19/2019 13:32 15.0 min 74.7 104.2 99.5 51.7 82 76 74 62 52 52 52 62 63 11/19/2019 13:47 15.0 min 70.8 100.3 87 51.6 82 76 74 62 54 52 52 62 62.5 11/19/2019 14:02 15.0 min 72.7 102.2 93.1 52.5 82 78 74 64 58 56 52 64 64.8 11/19/2019 14:17 15.0 min 73.6 103.1 92.9 56.7 84 78 76 66 60 58 56 66 66.6 11/19/2019 14:32 15.0 min 71.9 101.4 84.5 53.3 82 76 74 68 62 60 56 68 67.6 11/19/2019 14:47 15.0 min 71.5 101 85 52.2 80 76 74 66 54 54 52 66 65.1 11/19/2019 15:02 15.0 min 72.5 102 92.2 50.9 82 76 74 66 54 52 50 66 64.9 11/19/2019 15:17 15.0 min 71.4 100.9 87.7 51.8 82 76 74 64 54 52 52 64 63.6 11/19/2019 15:32 15.0 min 72.5 102 90 49.7 82 78 74 66 52 52 50 66 64.6 11/19/2019 15:47 15.0 min 71.7 101.2 88.9 50.8 80 76 74 64 54 52 52 64 64.5 11/19/2019 16:02 15.0 min 72.1 101.6 87.2 48.7 84 78 74 62 52 50 48 62 63 11/19/2019 16:17 15.0 min 70.8 100.3 86.1 47.3 82 76 74 60 52 50 48 60 61.5 11/19/2019 16:32 15.0 min 73.9 103.4 94.4 52.5 82 78 76 66 56 54 52 66 65.6 11/19/2019 16:47 15.0 min 70.7 100.2 86.8 48.4 80 76 72 66 52 50 48 66 63.6 11/19/2019 17:02 15.0 min 71.4 100.9 87.4 64.2 82 76 72 66 64 64 64 66 67.3 11/19/2019 17:17 15.0 min 71.1 100.6 84.6 64.7 78 76 74 66 64 64 64 66 68 11/19/2019 17:32 15.0 min 70.5 100 85.3 50.5 80 76 74 66 54 52 50 66 64.9 11/19/2019 17:47 15.0 min 67.6 97.1 84 48.8 78 74 70 54 50 50 50 54 57.9 11/19/2019 18:02 15.0 min 69 98.5 86.7 49.2 80 74 72 56 50 50 48 56 58.5 11/19/2019 18:17 15.0 min 67.2 96.7 85.4 48.6 80 72 68 52 50 48 48 52 55.2 11/19/2019 18:32 15.0 min 68.3 97.8 85.8 49 80 74 70 54 50 50 48 54 57 11/19/2019 18:47 15.0 min 67.6 97.1 86.6 48.9 80 74 70 52 48 48 48 52 55.9 11/19/2019 19:02 15.0 min 65.6 95.1 81.3 49.1 78 72 68 52 50 50 48 52 55.2 11/19/2019 19:17 15.0 min 67.7 97.2 84.4 49.8 80 74 68 52 50 50 50 52 56.2 11/19/2019 19:32 15.0 min 68.2 97.7 83.9 51.5 80 74 70 56 52 52 50 56 59.4 11/19/2019 19:47 15.0 min 69.3 98.8 91.7 46.1 80 72 68 56 48 48 46 56 58.4 11/19/2019 20:02 15.0 min 70 99.5 87.8 44.1 82 76 70 52 46 46 44 52 55.3 11/19/2019 20:17 15.0 min 66.8 96.3 83.1 45.2 80 72 68 48 46 46 44 48 52.7 11/19/2019 20:32 15.0 min 63 92.5 81.5 46.7 78 66 56 50 48 46 46 50 51.6 11/19/2019 20:47 15.0 min 69.3 98.8 83.6 47.7 80 76 72 54 48 48 48 54 57 11/19/2019 21:02 15.0 min 66.9 96.4 84.6 48.5 78 74 70 52 48 48 48 52 55.4 11/19/2019 21:17 15.0 min 67.4 96.9 88.2 49 80 72 68 50 50 48 48 50 54.3 11/19/2019 21:32 15.0 min 67.5 97 86.1 49.4 78 74 70 54 50 50 48 54 57.8 11/19/2019 21:47 15.0 min 64.4 93.9 83.3 48.8 76 70 66 50 48 48 48 50 53.5 11/19/2019 22:02 15.0 min 65 94.5 82.2 46.8 78 70 62 50 48 46 46 50 52 11/19/2019 22:17 15.0 min 65.7 95.2 81.6 46.7 78 74 68 50 48 46 46 50 53 11/19/2019 22:32 15.0 min 59.7 89.2 82.6 46.6 70 60 56 48 46 46 46 48 49.8 11/19/2019 22:47 15.0 min 64 93.5 80.8 46.7 76 70 66 50 46 46 46 50 53 11/19/2019 23:02 15.0 min 62.1 91.6 79.9 46.4 74 68 62 48 46 46 46 48 51.1 11/19/2019 23:17 15.0 min 61.2 90.7 80.7 46.3 72 68 64 48 46 46 46 48 51.5 11/19/2019 23:32 15.0 min 61.8 91.3 85 45.5 72 60 52 46 46 46 44 46 48.4 11/19/2019 23:47 15.0 min 62.1 91.6 82.2 44.8 76 60 52 46 44 44 44 46 47.9 11/20/2019 0:02 15.0 min 63.1 92.6 84 43.8 76 68 52 46 44 44 44 46 48.2 11/20/2019 0:17 15.0 min 56.4 85.9 77.8 43.1 70 54 50 44 44 42 42 44 46 11/20/2019 0:32 15.0 min 62.2 91.7 82.1 39.7 76 66 58 42 40 40 40 42 45.6 11/20/2019 0:47 15.0 min 60.1 89.6 83.3 39.2 72 52 48 40 38 38 38 40 42.5 11/20/2019 1:02 15.0 min 57.9 87.4 81.2 39.2 70 58 54 42 40 38 38 42 44.6 11/20/2019 1:17 15.0 min 62 91.5 82.8 39.2 76 62 54 42 40 40 38 42 45.3 11/20/2019 1:32 15.0 min 62.9 92.4 86.8 40.2 76 62 58 42 40 40 40 42 46 11/20/2019 1:47 15.0 min 61.5 91 81.5 39.1 74 64 56 42 38 38 38 42 44.9 11/20/2019 2:02 15.0 min 66.4 95.9 88 39.2 80 68 56 44 40 40 38 44 46.5 11/20/2019 2:17 15.0 min 58.4 87.9 79 42.2 72 62 52 44 42 42 42 44 46.4 11/20/2019 2:32 15.0 min 61.3 90.8 84.1 42.2 72 58 52 44 42 42 42 44 46.2 11/20/2019 2:47 15.0 min 61.4 90.9 80.8 43.9 74 64 56 46 44 44 44 46 48.8 11/20/2019 3:02 15.0 min 65.9 95.4 84.6 44.5 78 70 60 46 44 44 44 46 49.8 11/20/2019 3:17 15.0 min 64.8 94.3 83.2 45 78 70 62 48 44 44 44 48 50.8 11/20/2019 3:32 15.0 min 62.9 92.4 82 47.9 76 66 58 50 48 48 48 50 51.8 11/20/2019 3:47 15.0 min 68.6 98.1 87 46.7 82 74 66 50 48 46 46 50 52.9 11/20/2019 4:02 15.0 min 65.9 95.4 86.4 46.9 80 68 62 48 46 46 46 48 51.2 11/20/2019 4:17 15.0 min 68.8 98.3 88.6 47.9 80 76 72 50 48 48 48 50 55.3 11/20/2019 4:32 15.0 min 67.9 97.4 89.1 47.1 78 74 68 50 48 48 46 50 54 11/20/2019 4:47 15.0 min 68.5 98 89.9 44 80 74 68 50 44 44 44 50 53.7 11/20/2019 5:02 15.0 min 69.9 99.4 88.6 45.1 82 76 70 54 48 46 46 54 56.6 11/20/2019 5:17 15.0 min 72 101.5 89 51.8 84 78 74 58 54 52 52 58 61.2 11/20/2019 5:32 15.0 min 71.2 100.7 85.7 52.3 82 78 76 56 52 52 52 56 60.2 11/20/2019 5:47 15.0 min 71.1 100.6 85.7 51.3 82 78 76 56 52 52 50 56 60.1 11/20/2019 6:02 15.0 min 71.5 101 95.4 51.6 82 76 72 56 52 52 52 56 59 11/20/2019 6:17 15.0 min 72.8 102.3 89.2 51.5 82 78 76 64 54 52 52 64 64.6 11/20/2019 6:32 15.0 min 73 102.5 87.2 54.1 82 78 76 66 56 54 54 66 66.1 11/20/2019 6:47 15.0 min 71.7 101.2 84.5 53.2 80 76 76 66 54 54 52 66 65.4 11/20/2019 7:02 15.0 min 72.5 102 86.6 55.1 80 76 76 68 60 58 56 68 68.1 11/20/2019 7:17 15.0 min 73.7 103.2 91.1 58 82 78 76 68 62 60 58 68 68.7 11/20/2019 7:32 15.0 min 72.5 102 87.9 52.4 82 78 76 66 54 52 52 66 64.5 11/20/2019 7:47 15.0 min 71.7 101.2 89.7 51.7 82 78 76 60 52 52 52 60 61.6 11/20/2019 8:02 15.0 min 70.3 99.8 87.2 52.8 82 76 74 60 54 52 52 60 61.5 11/20/2019 8:17 15.0 min 71 100.5 84.3 52.4 80 76 74 64 54 52 52 64 63.8 11/20/2019 8:32 15.0 min 71 100.5 87 59.8 82 76 74 64 60 60 60 64 65.6 11/20/2019 8:47 15.0 min 71.8 101.3 87.8 49.8 84 78 74 58 52 50 50 58 60.6 11/20/2019 9:02 15.0 min 71.1 100.6 86.1 51.1 82 78 74 62 52 52 50 62 63.3 11/20/2019 9:17 15.0 min 70.2 99.7 86 50.6 80 76 74 60 52 52 50 60 61.4 11/20/2019 9:32 15.0 min 69.3 98.8 84.5 49.9 80 76 72 56 50 50 50 56 59.7 11/20/2019 9:47 15.0 min 70.2 99.7 85.9 50.4 80 76 74 60 52 52 50 60 61.6 11/20/2019 10:02 15.0 min 69.6 99.1 87.6 52.3 80 76 72 58 52 52 52 58 60.6 11/20/2019 10:17 15.0 min 70 99.5 85.4 50.9 80 76 74 56 52 50 50 56 59.8 11/20/2019 10:32 15.0 min 70.7 100.2 87.6 51.9 82 76 74 60 52 52 52 60 61.5 11/20/2019 10:47 15.0 min 71.3 100.8 92.8 50.8 82 76 74 58 52 52 50 58 60.7 11/20/2019 11:02 15.0 min 69.6 99.1 86.9 50.7 80 76 72 56 52 50 50 56 59.7 11/20/2019 11:17 12.3 min 71 99.7 82.8 49.7 80 78 76 58 52 50 50 58 60.5 APPENDIX F-2 Construction Noise Modeling Input and Output To User: bordered cells are inputs, unbordered cells have formulae 1 Construction Phase Equipment Total Equipment Qty AUF % (from FHWA RCNM) Reference Lmax @ 50 ft. from FHWA RCNM Client Equipment Description, Data Source and/or Notes Source to NSR Distance (ft.) Distance- Adjusted Lmax Allowable Operation Time (hours) Allowable Operation Time (minutes) Predicted 1- hour Leq Combined equipment type and quantity (for table in report document?) Demolition Excavator 1 40 81 90 75.9 8 480 81 Excavator (1) Excavator 1 40 81 150 71.5 8 480 77 Excavator (1) Excavator 1 40 81 200 69.0 8 480 74 Excavator (1) Concrete Saw 1 20 90 250 76.0 8 480 78 Concrete Saw (1) Dozer 1 40 82 300 66.4 8 480 71 Dozer (1) Dozer 1 40 82 350 65.1 8 480 70 Dozer (1) Total for Demolition Phase:84.5 Site Preparation Dozer 1 40 82 90 76.9 8 480 82 Dozer (1) Dozer 1 40 82 150 72.5 8 480 78 Dozer (1) Dozer 1 40 82 200 70.0 8 480 75 Dozer (1) Backhoe 1 40 78 250 64.0 8 480 69 Backhoe (1) Front End Loader 1 40 79 300 63.4 8 480 68 Front End Loader (1) Tractor 1 40 84 350 67.1 8 480 72 Tractor (1) Backhoe 1 40 78 400 59.9 8 480 65 Backhoe (1) Total for Site Preparation Phase:84.5 Grading Excavator 1 40 81 90 75.9 8 480 81 Excavator (1) Excavator 1 40 81 150 71.5 8 480 77 Excavator (1) Grader 1 40 85 200 73.0 8 480 78 Grader (1) Dozer 1 40 82 250 68.0 8 480 73 Dozer (1) Tractor 1 40 84 300 68.4 8 480 73 Tractor (1) Front End Loader 1 40 79 350 62.1 8 480 67 Front End Loader (1) Scraper 1 40 84 400 65.9 8 480 71 Scraper (1) Scraper 1 40 84 450 64.9 8 480 70 Scraper (1) Total for Grading Phase:84.8 Building Construction Generator 1 50 72 110 65.2 8 480 71 Generator (1) Crane 1 16 81 150 71.5 8 480 73 Crane (1) Man Lift 1 20 75 200 63.0 8 480 65 Man Lift (1) Man Lift 1 20 75 250 61.0 8 480 63 Man Lift (1) Man Lift 1 20 75 300 59.4 8 480 61 Man Lift (1) Tractor 1 40 84 350 67.1 8 480 72 Tractor (1) Front End Loader 1 40 79 400 60.9 8 480 66 Front End Loader (1) Backhoe 1 40 78 450 58.9 8 480 64 Backhoe (1) Welder / Torch 1 40 73 500 53.0 8 480 58 Welder / Torch (1) Total for Building Construction Phase:77.9 Paving Paver 1 50 77 90 71.9 8 480 78 Paver (1) Paver 1 50 77 150 67.5 8 480 73 Paver (1) Concrete Mixer Truck 1 40 79 200 67.0 8 480 72 Concrete Mixer Truck (1) Concrete Pump Truck 1 20 81 250 67.0 8 480 69 Concrete Pump Truck (1) Roller 1 20 80 300 64.4 8 480 66 Roller (1) Roller 1 20 80 350 63.1 8 480 65 Roller (1) Total for Paving Phase:80.6 Architectural Coating Compressor (air)1 40 78 110 71.2 8 480 76 Compressor (air) (1) Total for Architectural Coating Phase:76.2 NWC Santa Ana and Almond Warehouse RCNM prepared by Dudek South Receptor CD To User: bordered cells are inputs, unbordered cells have formulae 1 Construction Phase Equipment Total Equipment Qty AUF % (from FHWA RCNM) Reference Lmax @ 50 ft. from FHWA RCNM Client Equipment Description, Data Source and/or Notes Source to NSR Distance (ft.) Distance- Adjusted Lmax Allowable Operation Time (hours) Allowable Operation Time (minutes) Predicted 1- hour Leq Combined equipment type and quantity (for table in report document?) Demolition Excavator 1 40 81 400 62.9 8 480 68 Excavator (1) Excavator 1 40 81 400 62.9 8 480 68 Excavator (1) Excavator 1 40 81 400 62.9 8 480 68 Excavator (1) Concrete Saw 1 20 90 400 71.9 8 480 74 Concrete Saw (1) Dozer 1 40 82 400 63.9 8 480 69 Dozer (1) Dozer 1 40 82 400 63.9 8 480 69 Dozer (1) Total for Demolition Phase:77.8 Site Preparation Dozer 1 40 82 400 63.9 8 480 69 Dozer (1) Dozer 1 40 82 400 63.9 8 480 69 Dozer (1) Dozer 1 40 82 400 63.9 8 480 69 Dozer (1) Backhoe 1 40 78 400 59.9 8 480 65 Backhoe (1) Front End Loader 1 40 79 400 60.9 8 480 66 Front End Loader (1) Tractor 1 40 84 400 65.9 8 480 71 Tractor (1) Backhoe 1 40 78 400 59.9 8 480 65 Backhoe (1) Total for Site Preparation Phase:76.7 Grading Excavator 1 40 81 400 62.9 8 480 68 Excavator (1) Excavator 1 40 81 400 62.9 8 480 68 Excavator (1) Grader 1 40 85 400 66.9 8 480 72 Grader (1) Dozer 1 40 82 400 63.9 8 480 69 Dozer (1) Tractor 1 40 84 400 65.9 8 480 71 Tractor (1) Front End Loader 1 40 79 400 60.9 8 480 66 Front End Loader (1) Scraper 1 40 84 400 65.9 8 480 71 Scraper (1) Scraper 1 40 84 400 65.9 8 480 71 Scraper (1) Total for Grading Phase:78.9 Building Construction Generator 1 50 72 400 53.9 8 480 60 Generator (1) Crane 1 16 81 400 62.9 8 480 64 Crane (1) Man Lift 1 20 75 400 56.9 8 480 59 Man Lift (1) Man Lift 1 20 75 400 56.9 8 480 59 Man Lift (1) Man Lift 1 20 75 400 56.9 8 480 59 Man Lift (1) Tractor 1 40 84 400 65.9 8 480 71 Tractor (1) Front End Loader 1 40 79 400 60.9 8 480 66 Front End Loader (1) Backhoe 1 40 78 400 59.9 8 480 65 Backhoe (1) Welder / Torch 1 40 73 400 54.9 8 480 60 Welder / Torch (1) Total for Building Construction Phase:74.2 Paving Paver 1 50 77 400 58.9 8 480 65 Paver (1) Paver 1 50 77 400 58.9 8 480 65 Paver (1) Concrete Mixer Truck 1 40 79 400 60.9 8 480 66 Concrete Mixer Truck (1) Concrete Pump Truck 1 20 81 400 62.9 8 480 65 Concrete Pump Truck (1) Roller 1 20 80 400 61.9 8 480 64 Roller (1) Roller 1 20 80 400 61.9 8 480 64 Roller (1) Total for Paving Phase:72.6 Architectural Coating Compressor (air)1 40 78 400 59.9 8 480 65 Compressor (air) (1) Total for Architectural Coating Phase:65.0 South Receptor AC NWC Santa Ana and Almond Warehouse RCNM To User: bordered cells are inputs, unbordered cells have formulae 1 Construction Phase Equipment Total Equipment Qty AUF % (from FHWA RCNM) Reference Lmax @ 50 ft. from FHWA RCNM Client Equipment Description, Data Source and/or Notes Source to NSR Distance (ft.) Distance- Adjusted Lmax Allowable Operation Time (hours) Allowable Operation Time (minutes) Predicted 1- hour Leq Combined equipment type and quantity (for table in report document?) Demolition Excavator 1 40 81 70 78.1 8 480 83 Excavator (1) Excavator 1 40 81 100 75.0 8 480 80 Excavator (1) Excavator 1 40 81 150 71.5 8 480 77 Excavator (1) Concrete Saw 1 20 90 200 78.0 8 480 80 Concrete Saw (1) Dozer 1 40 82 250 68.0 8 480 73 Dozer (1) Dozer 1 40 82 300 66.4 8 480 71 Dozer (1) Total for Demolition Phase:86.9 Site Preparation Dozer 1 40 82 70 79.1 8 480 84 Dozer (1) Dozer 1 40 82 100 76.0 8 480 81 Dozer (1) Dozer 1 40 82 150 72.5 8 480 78 Dozer (1) Backhoe 1 40 78 200 66.0 8 480 71 Backhoe (1) Front End Loader 1 40 79 250 65.0 8 480 70 Front End Loader (1) Tractor 1 40 84 300 68.4 8 480 73 Tractor (1) Backhoe 1 40 78 350 61.1 8 480 66 Backhoe (1) Total for Site Preparation Phase:86.9 Grading Excavator 1 40 81 70 78.1 8 480 83 Excavator (1) Excavator 1 40 81 100 75.0 8 480 80 Excavator (1) Grader 1 40 85 150 75.5 8 480 81 Grader (1) Dozer 1 40 82 200 70.0 8 480 75 Dozer (1) Tractor 1 40 84 250 70.0 8 480 75 Tractor (1) Front End Loader 1 40 79 300 63.4 8 480 68 Front End Loader (1) Scraper 1 40 84 350 67.1 8 480 72 Scraper (1) Scraper 1 40 84 400 65.9 8 480 71 Scraper (1) Total for Grading Phase:87.1 Building Construction Generator 1 50 72 140 63.1 8 480 69 Generator (1) Crane 1 16 81 200 69.0 8 480 70 Crane (1) Man Lift 1 20 75 250 61.0 8 480 63 Man Lift (1) Man Lift 1 20 75 300 59.4 8 480 61 Man Lift (1) Man Lift 1 20 75 350 58.1 8 480 60 Man Lift (1) Tractor 1 40 84 400 65.9 8 480 71 Tractor (1) Front End Loader 1 40 79 450 59.9 8 480 65 Front End Loader (1) Backhoe 1 40 78 500 58.0 8 480 63 Backhoe (1) Welder / Torch 1 40 73 550 52.2 8 480 57 Welder / Torch (1) Total for Building Construction Phase:76.1 Paving Paver 1 50 77 70 74.1 8 480 80 Paver (1) Paver 1 50 77 100 71.0 8 480 77 Paver (1) Concrete Mixer Truck 1 40 79 150 69.5 8 480 75 Concrete Mixer Truck (1) Concrete Pump Truck 1 20 81 200 69.0 8 480 71 Concrete Pump Truck (1) Roller 1 20 80 250 66.0 8 480 68 Roller (1) Roller 1 20 80 300 64.4 8 480 66 Roller (1) Total for Paving Phase:83.1 Architectural Coating Compressor (air)1 40 78 140 69.1 8 480 74 Compressor (air) (1) Total for Architectural Coating Phase:74.1 East Receptor CD NWC Santa Ana and Almond Warehouse RCNM To User: bordered cells are inputs, unbordered cells have formulae 1 Construction Phase Equipment Total Equipment Qty AUF % (from FHWA RCNM) Reference Lmax @ 50 ft. from FHWA RCNM Client Equipment Description, Data Source and/or Notes Source to NSR Distance (ft.) Distance- Adjusted Lmax Allowable Operation Time (hours) Allowable Operation Time (minutes) Predicted 1- hour Leq Combined equipment type and quantity (for table in report document?) Demolition Excavator 1 40 81 375 63.5 8 480 69 Excavator (1) Excavator 1 40 81 375 63.5 8 480 69 Excavator (1) Excavator 1 40 81 375 63.5 8 480 69 Excavator (1) Concrete Saw 1 20 90 375 72.5 8 480 75 Concrete Saw (1) Dozer 1 40 82 375 64.5 8 480 70 Dozer (1) Dozer 1 40 82 375 64.5 8 480 70 Dozer (1) Total for Demolition Phase:78.3 Site Preparation Dozer 1 40 82 375 64.5 8 480 70 Dozer (1) Dozer 1 40 82 375 64.5 8 480 70 Dozer (1) Dozer 1 40 82 375 64.5 8 480 70 Dozer (1) Backhoe 1 40 78 375 60.5 8 480 66 Backhoe (1) Front End Loader 1 40 79 375 61.5 8 480 67 Front End Loader (1) Tractor 1 40 84 375 66.5 8 480 72 Tractor (1) Backhoe 1 40 78 375 60.5 8 480 66 Backhoe (1) Total for Site Preparation Phase:77.2 Grading Excavator 1 40 81 375 63.5 8 480 69 Excavator (1) Excavator 1 40 81 375 63.5 8 480 69 Excavator (1) Grader 1 40 85 375 67.5 8 480 73 Grader (1) Dozer 1 40 82 375 64.5 8 480 70 Dozer (1) Tractor 1 40 84 375 66.5 8 480 72 Tractor (1) Front End Loader 1 40 79 375 61.5 8 480 67 Front End Loader (1) Scraper 1 40 84 375 66.5 8 480 72 Scraper (1) Scraper 1 40 84 375 66.5 8 480 72 Scraper (1) Total for Grading Phase:79.5 Building Construction Generator 1 50 72 375 54.5 8 480 61 Generator (1) Crane 1 16 81 375 63.5 8 480 65 Crane (1) Man Lift 1 20 75 375 57.5 8 480 60 Man Lift (1) Man Lift 1 20 75 375 57.5 8 480 60 Man Lift (1) Man Lift 1 20 75 375 57.5 8 480 60 Man Lift (1) Tractor 1 40 84 375 66.5 8 480 72 Tractor (1) Front End Loader 1 40 79 375 61.5 8 480 67 Front End Loader (1) Backhoe 1 40 78 375 60.5 8 480 66 Backhoe (1) Welder / Torch 1 40 73 375 55.5 8 480 61 Welder / Torch (1) Total for Building Construction Phase:74.8 Paving Paver 1 50 77 375 59.5 8 480 66 Paver (1) Paver 1 50 77 375 59.5 8 480 66 Paver (1) Concrete Mixer Truck 1 40 79 375 61.5 8 480 67 Concrete Mixer Truck (1) Concrete Pump Truck 1 20 81 375 63.5 8 480 66 Concrete Pump Truck (1) Roller 1 20 80 375 62.5 8 480 65 Roller (1) Roller 1 20 80 375 62.5 8 480 65 Roller (1) Total for Paving Phase:73.2 Architectural Coating Compressor (air)1 40 78 375 60.5 8 480 66 Compressor (air) (1) Total for Architectural Coating Phase:65.6 East Receptor AC NWC Santa Ana and Almond Warehouse RCNM To User: bordered cells are inputs, unbordered cells have formulae 1 Construction Phase Equipment Total Equipment Qty AUF % (from FHWA RCNM) Reference Lmax @ 50 ft. from FHWA RCNM Client Equipment Description, Data Source and/or Notes Source to NSR Distance (ft.) Distance- Adjusted Lmax Allowable Operation Time (hours) Allowable Operation Time (minutes) Predicted 1- hour Leq Combined equipment type and quantity (for table in report document?) Demolition Excavator 1 40 81 120 73.4 8 480 78 Excavator (1) Excavator 1 40 81 150 71.5 8 480 77 Excavator (1) Excavator 1 40 81 200 69.0 8 480 74 Excavator (1) Concrete Saw 1 20 90 250 76.0 8 480 78 Concrete Saw (1) Dozer 1 40 82 300 66.4 8 480 71 Dozer (1) Dozer 1 40 82 350 65.1 8 480 70 Dozer (1) Total for Demolition Phase:83.6 Site Preparation Dozer 1 40 82 120 74.4 8 480 79 Dozer (1) Dozer 1 40 82 150 72.5 8 480 78 Dozer (1) Dozer 1 40 82 200 70.0 8 480 75 Dozer (1) Backhoe 1 40 78 250 64.0 8 480 69 Backhoe (1) Front End Loader 1 40 79 300 63.4 8 480 68 Front End Loader (1) Tractor 1 40 84 350 67.1 8 480 72 Tractor (1) Backhoe 1 40 78 400 59.9 8 480 65 Backhoe (1) Total for Site Preparation Phase:83.2 Grading Excavator 1 40 81 120 73.4 8 480 78 Excavator (1) Excavator 1 40 81 150 71.5 8 480 77 Excavator (1) Grader 1 40 85 200 73.0 8 480 78 Grader (1) Dozer 1 40 82 250 68.0 8 480 73 Dozer (1) Tractor 1 40 84 300 68.4 8 480 73 Tractor (1) Front End Loader 1 40 79 350 62.1 8 480 67 Front End Loader (1) Scraper 1 40 84 400 65.9 8 480 71 Scraper (1) Scraper 1 40 84 450 64.9 8 480 70 Scraper (1) Total for Grading Phase:83.9 Building Construction Generator 1 50 72 180 60.9 8 480 67 Generator (1) Crane 1 16 81 200 69.0 8 480 70 Crane (1) Man Lift 1 20 75 250 61.0 8 480 63 Man Lift (1) Man Lift 1 20 75 300 59.4 8 480 61 Man Lift (1) Man Lift 1 20 75 350 58.1 8 480 60 Man Lift (1) Tractor 1 40 84 400 65.9 8 480 71 Tractor (1) Front End Loader 1 40 79 450 59.9 8 480 65 Front End Loader (1) Backhoe 1 40 78 500 58.0 8 480 63 Backhoe (1) Welder / Torch 1 40 73 550 52.2 8 480 57 Welder / Torch (1) Total for Building Construction Phase:75.8 Paving Paver 1 50 77 120 69.4 8 480 75 Paver (1) Paver 1 50 77 150 67.5 8 480 73 Paver (1) Concrete Mixer Truck 1 40 79 200 67.0 8 480 72 Concrete Mixer Truck (1) Concrete Pump Truck 1 20 81 250 67.0 8 480 69 Concrete Pump Truck (1) Roller 1 20 80 300 64.4 8 480 66 Roller (1) Roller 1 20 80 350 63.1 8 480 65 Roller (1) Total for Paving Phase:79.5 Architectural Coating Compressor (air)1 40 78 180 66.9 8 480 72 Compressor (air) (1) Total for Architectural Coating Phase:71.9 Southeast Receptor CD NWC Santa Ana and Almond Warehouse RCNM To User: bordered cells are inputs, unbordered cells have formulae 1 Construction Phase Equipment Total Equipment Qty AUF % (from FHWA RCNM) Reference Lmax @ 50 ft. from FHWA RCNM Client Equipment Description, Data Source and/or Notes Source to NSR Distance (ft.) Distance- Adjusted Lmax Allowable Operation Time (hours) Allowable Operation Time (minutes) Predicted 1- hour Leq Combined equipment type and quantity (for table in report document?) Demolition Excavator 1 40 81 500 61.0 8 480 66 Excavator (1) Excavator 1 40 81 500 61.0 8 480 66 Excavator (1) Excavator 1 40 81 500 61.0 8 480 66 Excavator (1) Concrete Saw 1 20 90 500 70.0 8 480 72 Concrete Saw (1) Dozer 1 40 82 500 62.0 8 480 67 Dozer (1) Dozer 1 40 82 500 62.0 8 480 67 Dozer (1) Total for Demolition Phase:75.8 Site Preparation Dozer 1 40 82 500 62.0 8 480 67 Dozer (1) Dozer 1 40 82 500 62.0 8 480 67 Dozer (1) Dozer 1 40 82 500 62.0 8 480 67 Dozer (1) Backhoe 1 40 78 500 58.0 8 480 63 Backhoe (1) Front End Loader 1 40 79 500 59.0 8 480 64 Front End Loader (1) Tractor 1 40 84 500 64.0 8 480 69 Tractor (1) Backhoe 1 40 78 500 58.0 8 480 63 Backhoe (1) Total for Site Preparation Phase:74.7 Grading Excavator 1 40 81 500 61.0 8 480 66 Excavator (1) Excavator 1 40 81 500 61.0 8 480 66 Excavator (1) Grader 1 40 85 500 65.0 8 480 70 Grader (1) Dozer 1 40 82 500 62.0 8 480 67 Dozer (1) Tractor 1 40 84 500 64.0 8 480 69 Tractor (1) Front End Loader 1 40 79 500 59.0 8 480 64 Front End Loader (1) Scraper 1 40 84 500 64.0 8 480 69 Scraper (1) Scraper 1 40 84 500 64.0 8 480 69 Scraper (1) Total for Grading Phase:77.0 Building Construction Generator 1 50 72 500 52.0 8 480 58 Generator (1) Crane 1 16 81 500 61.0 8 480 62 Crane (1) Man Lift 1 20 75 500 55.0 8 480 57 Man Lift (1) Man Lift 1 20 75 500 55.0 8 480 57 Man Lift (1) Man Lift 1 20 75 500 55.0 8 480 57 Man Lift (1) Tractor 1 40 84 500 64.0 8 480 69 Tractor (1) Front End Loader 1 40 79 500 59.0 8 480 64 Front End Loader (1) Backhoe 1 40 78 500 58.0 8 480 63 Backhoe (1) Welder / Torch 1 40 73 500 53.0 8 480 58 Welder / Torch (1) Total for Building Construction Phase:72.3 Paving Paver 1 50 77 500 57.0 8 480 63 Paver (1) Paver 1 50 77 500 57.0 8 480 63 Paver (1) Concrete Mixer Truck 1 40 79 500 59.0 8 480 64 Concrete Mixer Truck (1) Concrete Pump Truck 1 20 81 500 61.0 8 480 63 Concrete Pump Truck (1) Roller 1 20 80 500 60.0 8 480 62 Roller (1) Roller 1 20 80 500 60.0 8 480 62 Roller (1) Total for Paving Phase:70.7 Architectural Coating Compressor (air)1 40 78 500 58.0 8 480 63 Compressor (air) (1) Total for Architectural Coating Phase:63.1 Southeast Receptor AC NWC Santa Ana and Almond Warehouse RCNM APPENDIX F-3 Equipment Noise Calculations MECHANICAL EQUIPMENT NOISE LEVEL Input: Equipment Locations / Source Noise Data LwA Site X Y Elev. At Roof or Ground Source Height Single Source Number of Units Sound Level at 50 feet Total Equip. Location Site / Number Frequency (in Hz)500 HVAC 1 Bldg 1 968.00 1,748.50 40 3 80 1 48 HVAC 1 Bldg 1 York ZF-048 HVAC 2 Bldg 1 997.00 1,748.50 40 3 80 1 48 HVAC 2 Bldg 1 York ZF-048 Building Elevation Roof Elevation Receivers at P.L.Applicable Standard 0 40 North P.L.982 2304.758 0 65 South P.L.982 1700.877 0 65 East P.L.1192.969 1748.5 0 65 West P.L.591.5152 1748.5 0 65 Output:Location:Applicable Standard North P.L.982.0 2304.8 0 65 Source Coordinates Receiver Coordinate s Location- Equipment Leq (h) at 50' Receiver Elevation Source Elevation Source to Receiver Source to Barrier Receiver to Barrier Barrier (base)Barrier Height Fresnel No.Barrier Leq w/o Barrier Leq w/Barrier Equip Site X Y Z X Y (dBA)(feet)(feet)(feet)(feet)(feet)(feet)(feet) at 500 Hz Attenuation (dBA) (dBA)(dBA) HVAC 1 Bldg 1 968 1748.5024 40 982 2304.7576 York ZF-048 48 5 43.0 556 20 536 40 6.0 0.44 11 27 17 HVAC 2 Bldg 1 997 1748.5024 40 982 2304.7576 York ZF-048 48 5 43.0 556 35 521 40 6.0 0.39 10 27 17 TOTAL Leq:30 20 Without With Barrier/ Barrier Parapet North PL NWC HVAC Noise Calcs MECHANICAL EQUIPMENT NOISE LEVEL Input: Equipment Locations / Source Noise Data LwA Site X Y Elev. At Roof or Ground Source Height Single Source Number of Units Sound Level at 50 feet Total Equip. Location Site / Number Frequency (in Hz)500 HVAC 1 Bldg 1 968.00 1,748.50 40 3 80 1 48 HVAC 1 Bldg 1 York ZF-048 HVAC 2 Bldg 1 997.00 1,748.50 40 3 80 1 48 HVAC 2 Bldg 1 York ZF-048 Building Elevation Roof Elevation Receivers at P.L.Applicable Standard 0 40 North P.L.982 2304.758 0 65 South P.L.982 1700.877 0 65 East P.L.1192.969 1748.5 0 65 West P.L.591.5152 1748.5 0 65 Output:Location:Applicable Standard South P.L.982.0 1700.9 0 65 Source Coordinates Receiver Coordinate s Location- Equipment Leq (h) at 50' Receiver Elevation Source Elevation Source to Receiver Source to Barrier Receiver to Barrier Barrier (base)Barrier Height Fresnel No.Barrier Leq w/o Barrier Leq w/Barrier Equip Site X Y Z X Y (dBA)(feet)(feet)(feet)(feet)(feet)(feet)(feet) at 500 Hz Attenuation (dBA) (dBA)(dBA) HVAC 1 Bldg 1 968 1748.5024 40 982 1700.8768 York ZF-048 48 5 43.0 50 20 30 40 6.0 7.41 22 48 28 HVAC 2 Bldg 1 997 1748.5024 40 982 1700.8768 York ZF-048 48 5 43.0 50 35 15 40 6.0 14.30 25 48 28 TOTAL Leq:51 31 Without With Barrier/ Barrier Parapet South PL NWC HVAC Noise Calcs MECHANICAL EQUIPMENT NOISE LEVEL Input: Equipment Locations / Source Noise Data LwA Site X Y Elev. At Roof or Ground Source Height Single Source Number of Units Sound Level at 50 feet Total Equip. Location Site / Number Frequency (in Hz)500 HVAC 1 Bldg 1 968.00 1,748.50 40 3 80 1 48 HVAC 1 Bldg 1 York ZF-048 HVAC 2 Bldg 1 997.00 1,748.50 40 3 80 1 48 HVAC 2 Bldg 1 York ZF-048 Building Elevation Roof Elevation Receivers at P.L.Applicable Standard 0 40 North P.L.982 2304.758 0 65 South P.L.982 1700.877 0 65 East P.L.1192.969 1748.5 0 65 West P.L.591.5152 1748.5 0 65 Output:Location:Applicable Standard East P.L.1193.0 1748.5 0 65 Source Coordinates Receiver Coordinate s Location- Equipment Leq (h) at 50' Receiver Elevation Source Elevation Source to Receiver Source to Barrier Receiver to Barrier Barrier (base)Barrier Height Fresnel No.Barrier Leq w/o Barrier Leq w/Barrier Equip Site X Y Z X Y (dBA)(feet)(feet)(feet)(feet)(feet)(feet)(feet) at 500 Hz Attenuation (dBA) (dBA)(dBA) HVAC 1 Bldg 1 968 1748.5024 40 1192.9688 1748.5 York ZF-048 48 5 43.0 225 20 205 40 6.0 0.98 14 35 22 HVAC 2 Bldg 1 997 1748.5024 40 1192.9688 1748.5 York ZF-048 48 5 43.0 196 35 161 40 6.0 1.44 15 36 21 TOTAL Leq:39 25 Without With Barrier/ Barrier Parapet East PL NWC HVAC Noise Calcs MECHANICAL EQUIPMENT NOISE LEVEL Input: Equipment Locations / Source Noise Data LwA Site X Y Elev. At Roof or Ground Source Height Single Source Number of Units Sound Level at 50 feet Total Equip. Location Site / Number Frequency (in Hz)500 HVAC 1 Bldg 1 968.00 1,748.50 40 3 80 1 48 HVAC 1 Bldg 1 York ZF-048 HVAC 2 Bldg 1 997.00 1,748.50 40 3 80 1 48 HVAC 2 Bldg 1 York ZF-048 Building Elevation Roof Elevation Receivers at P.L.Applicable Standard 0 40 North P.L.982.0 2304.8 0 65 South P.L.982.0 1700.9 0 65 East P.L.1193.0 1748.5 0 65 West P.L.591.5 1748.5 0 65 Output:Location:Applicable Standard West P.L.591.5 1748.5 0 65 Source Coordinates Receiver Coordinate s Location- Equipment Leq (h) at 50' Receiver Elevation Source Elevation Source to Receiver Source to Barrier Receiver to Barrier Barrier (base)Barrier Height Fresnel No.Barrier Leq w/o Barrier Leq w/Barrier Equip Site X Y Z X Y (dBA)(feet)(feet)(feet)(feet)(feet)(feet)(feet) at 500 Hz Attenuation (dBA) (dBA)(dBA) HVAC 1 Bldg 1 968 1748.5024 40 591.5152 1748.5 York ZF-048 48 5 43.0 376 273 103 40 6.0 5.29 20 31 11 HVAC 2 Bldg 1 997 1748.5024 40 591.5152 1748.5 York ZF-048 48 5 43.0 405 300 105 40 6.0 5.29 20 30 10 TOTAL Leq:33 13 Without With Barrier/ Barrier Parapet West PL NWC HVAC Noise Calcs RAY-TRACE PROGRAM (FOR A POINT-SOURCE) Uses the Equation: (Ae4)point=20*log[(2*pi*N)1/2/tanh(2*pi*N)1/2]+5dB (Ref. Pg.174, Noise and Vibration Control, L.L. Beranek Editor, 1971 Ed. Project: Santa Ana and Almond Avenue Warehouse Project Date: 09/22/22 By: MG Please Enter: Using English (E) units or Metric (M) units ? E Ray Trace Number/Description Source- Receiver Distance (ft. or m) Source Base Elev. (ft. or m) Source Height above Ground (ft. or m) Receiver Base Elev. (ft. or m) Receiver Height above Ground (ft. or m) Horizontal Barrier Dist. (in ref. to source) (ft. or m) Barrier Base Elev. (ft. or m) Barrier Height (ft. or m) Dominant Freq.(Hz) Source- Rcvr Straight- Line Dist. (ft. or m) Source- Top-of- Barrier Dist. (ft. or m) Receiver- Top-of- Barrier Dist. (ft. or m) Lambda Nmax AE (barriers) (dB) 1. Source -Truck Noise - N/S PL 200.0 0.0 10.0 0.0 5.0 30.0 0.0 40.0 500.0 200.1 42.4 173.6 2.3 14.1 24.5 1. Source -Truck Noise - N. Resi 325.0 0.0 10.0 0.0 5.0 30.0 0.0 40.0 500.0 325.0 42.4 297.1 2.3 12.8 24.1 #REF! FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 251933-YTG-Y-0715 TECHNICAL GUIDE Description YORK® ZE/ZF/ZR/XN/XP Series units are convertible single package high efficiency rooftops with a common roof curb for the 3, 4, 5 and 6 Ton sizes (ZE, ZR, XN, XP not available in 6 Ton). Although the units are primarily designed for curb mounting on a roof, they can also be slab-mounted at ground level or set on steel beams above a finished roof. All ZE/ZF/ZR/XN/XP Series units are self-contained and assembled on rigid full perimeter base rails allowing for overhead rigging. Every unit is completely charged, wired, piped and tested at the factory to provide a quick and easy field installation. All models (including those with an economizer) are convertible between bottom and horizontal duct connections. ZE/ZF/ZR Series units are available in the following configurations: cooling only, cooling with electric heat, and cooling with one or two stage gas heat. Electric heaters are available as factory-installed option or field installed accessory. XN/XP Series units are available in the following configurations: cooling and heating only and cooling and heating with electric heat. Tested in accordance with: R-410A ZE/ZF/ZR/XN/XP SERIES 3 - 6 TON 60 Hertz 251933-YTG-Y-0715 2 Johnson Controls Unitary Products Table of Contents Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Component Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Guide Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Capacity Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Airflow Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Sound Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 Typical Field Power and Control Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143 Weights and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147 Component Location Gas/Electric Smoke Detector 3/4” PVC Female Condensate Drain GFCI Convenience Outlet Knockout For Side Control Entry Simplicity® Lite™ Or Simplicity SE Control Board Knockout For Side Gas Supply Entry Full Perimeter Baserails With Forklift Slots And Lifting Holes Highly Efficient Enhanced Copper Tube/Enhanced Aluminum Fin Or Micro-Channel Aluminum Tube/Aluminum Fin Condenser High Efficiency Compressor Power Ventor Motor With Post Purge Cycle20 Gauge Aluminized Steel Tubular Heat Exchanger Belt Drive Or Direct Drive Blower HACR BreakerEconomizer Hood Knockout For Side Power Entry Slide-In Economizer 251933-YTG-Y-0715 Johnson Controls Unitary Products 3 Electric/Electric and Heat Pump Economizer Hood Electric Heat Accessory Location High Efficiency Compressor Highly Efficient Enhanced Copper Tube/Enhanced Aluminum Fin Or Micro-Channel Aluminum Tube/Aluminum Fin Condenser Full Perimeter Baserails With Forklift Slots And Lifting Holes Simplicity® Lite™ Or Simplicity® SE Control Board Belt Drive Or Direct Drive Blower Knockout For Side Control Entry GFCI Convenience Outlet 3/4” PVC Female Condensate Drain Smoke Detector Slide-In Economizer Knockout For Side Power Entry HACR Breaker 251933-YTG-Y-0715 4 Johnson Controls Unitary Products Nomenclature Z E 048 N04 A 2 A AA 4 0 1 2 4 A Z = A/C, Single Pkg., R-410A X = HP, Single Pkg., R-410A Product Category Airflow A = Direct Drive4 B = Direct Drive/Single Input Low Leak Econo4 D = Direct Drive/Motorized Damper4 N = Belt Drive P = Belt Drive/Single Input Low Leak Econo R = Belt Drive/Motorized Damper T = Belt Drive High Static U = Belt Drive High Static/Single Input Low Leak Economizer V = Belt Drive High Static/Motorized Damper Product Generation 4 = Fourth Generation *(D, T)10 = 92 MBH Output on 036 Models 036 = 3.0 Ton Nominal Cooling Capacity 048 = 4.0 Ton 060 = 5.0 Ton 072 = 6.0 Ton Product Identifier = 11.2 EER2, A/C = 11.0 EER3, CLG/GAS R = 13.0 SEER Reheat P = 13.0 SEER HP Product Style A = Style A SS Drain Pan Configuration Options (not required for all units) These four digits will not be assigned until a quote is requested, or an order placed. CPC Controller, DFS, APS Honeywell Controller, DFS, APS Novar Controller, DFS, APS 2" Pleated Filters, MERV 7 BAS Ready Economizer (2-10 V.D.C. Actuator Without a Controller) Any Combination of Additional Options that Don’t Have an Option Code Pre-assigned 1. 3 thru 5 Ton Units 2. 6 Ton Units Cooling Only / Cooling With Electric Heat 3. 6 Ton Unit Cooling With Gas Heat 4. 208/230-1-60 Not Available On 13 SEER Units F = 13.0 SEER1, A/C E = 14.0 SEER, A/C N = 14.0 SEER HP Simplicity® Smart Equipment (SSE) w/Communication BACnet MS/TP (programmable to Modbus or N2 protocols) Johnson Controller UNT 1126 (N2 protocol), DFS, APS C00 = Cooling Only. Suitable for Field Installed Electric Heat Heat Type and Nominal Heat Capacity N04 = 40 MBH Output Aluminized Steel, 1 Stage (036) N06 = 60 MBH Output Aluminized Steel, 1 Stage (048) N08 = 80 MBH Output Aluminized Steel, 1 Stage (036, 060, 072) N10 = 100 MBH Output Aluminized Steel, 1 Stage (048, 060, 072) D06 = 60 MBH Output Aluminized Steel, 2 Stage (036, 048, 060, 072) D10 = 100 MBH Output Aluminized Steel, 2 Stage (036*, 048, 060, 072) S04 = 40 MBH Output Stainless Steel, 1 Stage (036) S06 = 60 MBH Output Stainless Steel, 1 Stage (048) S08 = 80 MBH Output Stainless Steel, 1 Stage (036, 060, 072) S10 = 100 MBH Output Stainless Steel, 1 Stage (048, 060, 072) T06 = 60 MBH Output Stainless Steel, 2 Stage (036, 048, 060, 072) T10 = 100 MBH Output Stainless Steel, 2 Stage (036*, 048, 060, 072) E05 = 5 KW E07 = 7 KW E10 = 10 KW E15 = 15 KW E20 = 20 KW E30 = 30 KW Gas Heat Options Electric Heat Options Voltage 1 = 208/230-1-60 2 = 208/230-3-60 4 = 460-3-60 5 = 575-3-60 York Commercial Comfort System (YCCS) Rtu Controller 3 = 380-3-60 A = No Options Installed Installation Options B = Option 1 C = Option 2 D = Options 1 & 2 E = Option 3 F = Option 4 G = Options 1 & 3 H = Options 1 & 4 J = Options 1, 2 & 3 K = Options 1, 2, & 4 L = Options 1,3 & 4 M = Options 1, 2, 3, & 4 N = Options 2 & 3 P = Options 2 & 4 Q = Options 2, 3, & 4 R = Options 3 & 4 S = Option 5 T = Options 1 & 5 U = Options 1, 3, & 5 V = Options 1, 4, & 5 W = Options 1, 3, 4, & 5 X = Options 3 & 5 Y = Options 4 & 5 Z = Options 3, 4 & 5 1 = Disconnect 2 = Non-Pwr'd Conv. Outlet 3 = Smoke Detector S.A. 4 = Smoke Detector R.A. 5 = Pwr'd Conv. Outlet Options AA = None AB = Phase Monitor AC = Coil Guard AD = Dirty Filter Switch AE = Phase Monitor & Coil Guard AF = Phase Monitor & Dirty Filter Switch AG = Coil Guard & Dirty Filter Switch AH = Phase Monitor, Coil Guard & Dirty Filter Switch AS = Bottom Drain Connection RC = Coil Guard & American Flag TA = Technicoat Condenser Coil TJ = Technicoat Evaporator Coil TS = Technicoat Evaporator and Condenser Coil EA = E-Coat Condenser Coil EJ = E-Coat Evaporator Coil ES = E-Coat Cond & Evap Coils 1A = Simplicity SE 1B = Phase Monitor & Simplicity SE 1C = Coil Guard & Simplicity SE 1D = Dirty Filter Switch & Simplicity SE 1E = Phase Monitor, Coil Guard, Simplicity SE 1F = Phase Monitor, Dirty Filter Switch, Simplicity SE 1G = Coil Guard & Dirty Filter Switch, Simplicity SE 1H = Phase Monitor, Coil Guard, Dirty Filter Switch, Simplicity SE Standard Cabinet Additional Options ZZ = If desired option combination is not listed above, ZZ will be assigned and configuration options will be located in digits 15-18. Hinged & Toolless Access Cabinet BA = Hinged & Toolless Filter, Motor and Electrical Access Panels BB = Phase Monitor, Hinged & Toolless Filter, Motor and Electrical Access Panels BC = Coil Guard, Hinged & Toolless Filter, Motor and Electrical Access Panels BD = Dirty Filter Switch, Hinged & Toolless Filter, Motor and Electrical Access Panels BE = Phase Monitor & Coil Guard, Hinged & Toolless Filter, Motor and Electrical Access Panels BF = Phase Monitor & Dirty Filter Switch, Hinged & Toolless Filter, Motor and Electrical Access Panels BG = Coil Guard & Dirty Filter Switch, Hinged & Toolless Filter, Motor and Electrical Access Panels BH = Phase Monitor, Coil Guard & Dirty Filter Switch, Hinged & Toolless Filter, Motor and Electrical Access Panels 2A = Hinged & Toolless Access Panels, Simplicity SE 2B = Hinged & Toolless Access Panels, Phase Monitor, Simplicity SE 2C = Hinged & Toolless Access Panels, Coil Guard & Simplicity SE 2D = Hinged & Toolless Access Panels, Dirty Filter Switch, Simplicity SE 2E = Hinged & Toolless Access Panels, Phase Monitor, Coil Guard, Simplicity SE 2F = Hinged & Toolless Access Panels, Phase Monitor, Dirty Filter Switch, Simplicity SE 2G = Hinged & Toolless Access Panels, Coil Guard, Dirty Filter Switch, Simplicity SE 2H = Hinged & Toolless Access Panels, Phase Monitor, Coil Guard, Dirty Filter Switch, Simplicity SE 251933-YTG-Y-0715 Johnson Controls Unitary Products 5 Features and Benefits Standard Features •High Efficiency - High efficiency 3 thru 5 Ton units reach 14.0/13.0 SEER, 6 Ton Cooling only or Cooling with Electric Heat reach 11.2 EER and 6 Ton Cooling with Gas Heat reach 11.0 EER. Gas/electric units have electronic spark ignition and power vented combustion with steady state efficiencies of 80%. High efficiency heat pumps reach 14/13 SEER and 8.0/7.7 H.S.P. F. These efficiencies exceed all legislated minimum levels and provide low operating costs. •Coil Technology – All ZE/ZF condensers utilize Micro- Channel “all-aluminum” condensers which provide improved heat transfer capabilities and reduced charge volumes. All evaporators utilize a conventional copper tube/aluminum fin design for proven reliability and performance. •Convertible Airflow Design - All models (including those with an economizer) are suitable for either bottom or horizontal duct connections. For bottom duct, remove the sheet metal panels from the supply and return air openings through the base of the unit. For horizontal duct, remove the supply and return air panels on the rear of the unit. •System Protection - Suction line freezestats are supplied on all units to protect against loss of charge and coil frosting when the economizer operates at low outdoor air temperatures while the compressors are running. Every unit has solid-core liquid line filter-driers and high and low- pressure switches. Internal compressor protection is standard on all compressors. •Advanced Controls - ZE/ZF (Electric/Electric and Gas/ Electric) with no factory installed economizer or BAS options will come standard with the reliable Simplicity® Lite™ control. All ZE/ZF models with factory installed economizers or any BAS option, reheat (ZR) and heat pump (XP, XN) Units will come with the new state-of-the- art Simplicity SE (Smart Equipment) control system. The new unit control incorporates the best of the already proven Simplicity® unitary controls and creates a more robust, intelligent control. The goal of this control is to utilize cutting edge technology making the equipment easier to install, operate, and service. All units are Factory commissioned, configured, and run tested. Simplicity SE Control Board • Versatile - The Simplicity SE (not applicable with units utilizing Simplicity Lite) control can be configured to use with a standard thermostat (easy to connect screw terminals), A zone sensor, or can be setup to communicate with multiple BAS communication protocols to integrate with building automation systems. •Reduce field installed complexity - Each unit (not applicable with units utilizing Simplicity Lite) will comes equipped with factory installed supply air, return air, and outdoor air temperature sensors providing key temperature readings thus reduce field installed complexity. •On-board USB Port - The new control (not applicable with units utilizing Simplicity Lite) comes with a long list of features including data logging, current and previous system faults and software update capabilities using the on board USB port and common flash drive. Energy use monitoring capabilities allow custom tailoring to allow a system to work more efficiently at all times and occupancy levels. Self test and start-up reports also available from the board VIA the USB port. •Embedded LCD Display - The board (not applicable with units utilizing Simplicity Lite) has a easy to read, built-in LCD display and easy to use navigation joystick and buttons allowing the user to quickly navigate the menus displaying unit status, options, current function, supply, return and outdoor temperatures, fault codes and other information. •Low Ambient - An integrated low-ambient control allows all units to operate in the cooling mode down to 0F outdoor ambient without additional assistance. Optionally, the control board can be programmed to lockout the compressors when the outdoor air temperature is low or when free cooling is available. 251933-YTG-Y-0715 6 Johnson Controls Unitary Products •Anti-Short Cycle Protection - To aid compressor life, an anti-short cycle delay is incorporated into the standard controls. Compressor reliability is further ensured by programmable minimum run times. For testing, the anti-short cycle delay can be temporarily overridden with the push of a button. •Fan Delays - Fan on and fan off delays are fully programmable. Furthermore, the heating and cooling fan delay times are independent of one another. All units are programmed with default values based upon their configuration of cooling and heat. •Safety Monitoring - The control board monitors the high and low-pressure switches, the freezestats, the gas valve, if applicable, and the temperature limit switch on gas and electric heat units. The unit control board will alarm on ignition failures, compressor lockouts and repeated limit switch trips. •Nuisance Trip Protection and Strikes - To prevent nuisance trouble calls, the control board uses a “three times, you’re out” philosophy. The high and low- pressure switches and the freezestats must trip three times within two hours before the unit control board will lock out the associated compressor. •On Board Diagnostics - Each alarm will energize a trouble light on the thermostat, if so equipped, and flash an alarm code on the control board LED or on LCD with Simplicity SE controlled units. Each high and low- pressure switch alarm as well as each freezestat alarm has its own flash code. The control board saves the five most recent alarms in memory, and these alarms can be reviewed at any time. Alarms and programmed values are retained through the loss of power. •Reliable - From the beginning - All units undergo computer automated testing before they leave the factory. Units are tested for refrigerant charge and pressure, unit amperage, and 100% functionality. For the long term - All units are painted with a long lasting, powder paint that stands up over the life of the unit. The paint used has been proven by a 1000 hour salt spray test. •Flexible Placement - All models and configurations share the same cabinet/footprint and thus the same roof curb. You have the flexibility to set one curb and choose the correct tonnage size and heating option after the internal loads have been determined. •Full Perimeter Base Rails - The permanently attached base rails provide a solid foundation for the entire unit and protect the unit during shipment. The rails offer forklift access from 3 sides, and rigging holes are available so that an overhead crane can be used to place the units on a roof. •Easy Installation - Gas and electric utility knockouts are supplied in the unit underside as well as the side of the unit. A clearly identified location is provided to mount a field supplied electrical disconnect switch. Utility connections can be made quickly and with a minimum amount of field labor. •Wide Range of Indoor Airflows - Indoor fan motors are either direct-drive or belt-drive type providing maximum flexibility to handle most airflow requirements. •Gas Heat Operation - All single phase models with gas heat have minimum annual fuel utilization efficiency (AFUE) of 81%. All three phase models with gas heat have minimum steady state efficiency of 80%. Each section includes a durable heat exchanger with aluminized steel or optional stainless steel tubes, a redundant gas valve, spark ignition, power venting, an ignition module for 100% shut-off and all of the safety controls required to meet the latest ANSI standards. The gas supply piping can be routed into the heating compartment through a hole in the base pan of the unit or through a knockout in the piping panel on the front of the unit. Electric Heat Operation - All electric heat models are wired for a single power source and include a bank of nickel chromium elements mounted at the discharge of the supply air blower to provide a high velocity and uniform distribution of air across the heating elements. Every element is fully protected against excessive temperature by thermal limit switches. The power supply wiring can be routed into the control box through a threaded pipe connection (field supplied) in the base pan of the unit or through a knockout in the wiring panel on the side of the unit. •Warranty - All models include a 1-year limited warranty on the complete unit. Compressors and electric heater elements each carry a 5-year warranty. Aluminized steel and stainless steel tubular heat exchangers carry a 10- year warranty. Factory Installed Options NOTE: Simplicity Lite models are only available with a field installed Honeywell Jade economizer which is equipped standard with single enthalpy control (dual enthalpy available as field installed kit). Simplicity SE models are available with factory or field installed economizers including options for a SSE controlled economizer or an externally controlled BAS economizer where both feature standard dry bulb control (single and dual enthalpy available as field installed kits). •Economizers - All units offer a variety of optional factory installed economizers that are shipped, installed and wired with AMCA 511 Licensed Class 1A low leak The Simplicity® Lite or SE control board used in this product will effectively operate the cooling sys- tem down to 0°F when this product is applied in a comfort cooling application for people. An econo- mizer is typically included in this type of applica- tion. When applying this product for process cooling applications (computer rooms, switchgear, etc.), please reference applications bulletin AE- 011-07 or call the applications department for Uni- tary Products @ 1-877-UPG-SERV for guidance. Additional accessories may be needed for stable operation at temperatures below 30° F. 251933-YTG-Y-0715 Johnson Controls Unitary Products 7 dampers designed to exceed ASHRAE 90.1-2010 and the International Energy Conservation Code (IECC) certification requirements by achieving leakage rates of 3 cfm/ sq. ft. at 1" of static pressure. Each economizer goes through a rigorous 60,000 cycle test. Dry bulb, single enthalpy, and dual enthalpy (with field installed kit) can be selected. All economizer options are fully integrated into the Simplicity SE controls. The economizer has spring return, fully modulating damper actuators and is capable of introducing up to 100% outdoor air. As the outdoor air intake dampers open, the return air dampers close. The changeover from mechanical refrigeration to economizer operation is regulated by the outdoor air dry bulb temperature or the outdoor air enthalpy input. The dual enthalpy kit provides a second input used to monitor the return air (field installed). The installer needs only to assemble the outdoor air hood, attach the enthalpy control the hood and mount the hood to the unit (hood and control are provided). •Dry Bulb Economizer - Economizer operation is enabled by the outdoor air temperature being less than the setpoint of the economizer module. •Enthalpy Economizer - The added outdoor air enthalpy sensor enables economizer operation if the outdoor enthalpy is less than the setpoint of the economizer logic module. •Motorized Outdoor Air Intake Damper -Includes a slide- in / plug-in damper assembly with a 2-position, spring return motor actuator which opens to a pre-set position whenever the supply air blower is operating and will drive fully closed when the blower unit shuts down. The rain hood is painted to match the basic unit and must be field assembled before installing. •Technicoat Condenser Coils - The condenser coils are coated with a phenolic coating for protection against corrosion due to harsh environments. • Technicoat Evaporator Coil - The evaporator coils are coated with a phenolic coating for protection against corrosion due to harsh environments. • E-coat Condenser Coils - The condenser coils are coated with an epoxy polymer coating to protect against corrosion. • E-coat Evaporator Coils - The evaporator coils are coated with an epoxy polymer coating to protect against corrosion. •Electric Heaters - Wired for single point power supply. These nickel chromium heater elements are provided with limit and automatic reset capability to prevent operation at excessive temperatures. •Filter Options - Standard units are shipped with 1" throw- away filters installed. 2" Pleated Filters, MERV 7 are offered as a factory installed option. •Convenience Outlet - This 110 volt outlet can be “powered” by the unit with a stepdown transformer or the unit may be ordered with a “non-powered” convenience outlet that can be wired in the field. •Disconnect Switch - For gas heat units and cooling units with electric heat, a HACR breaker sized to the unit is provided. For cooling only units, a switch sized to the largest electric heat available for the particular unit is provided. Factory installed option only. •Smoke Detectors - (supply air & return air) The smoke detectors stop operation of the unit by interrupting power to the control board if smoke is detected within the air compartment. •Coil Guard - Customers can purchase a coil guard kit to protect the condenser coil from damage. This is not a hail guard kit. •Stainless Steel Heat Exchanger - For applications in corrosive environments, this option provides a full stainless steel heat exchanger assembly. •Stainless Steel Drain Pan - An optional rustproof stainless steel drain pan is available to provide years of trouble-free operation in corrosive environments. •Bottom Drain Connection - An optional bottom drain connection is available for inside the curb connections for applications in cold environments to reduce freezing drain lines. •Phase Monitors - Designed to prevent unit damage. The phase monitor will shut the unit down in an out-of phase condition. •Dirty Filter Switch - This kit includes a differential pressure switch that energizes the fault light on the unit thermostat, indicating that there is an abnormally high pressure drop across the filters. Factory installed option or field installed accessory. •Hinged & Toolless Filter, Motor and Electrical Access Panels - This option allows for easy access and maintenance. NOTE: Knobs are shipped inside the unit to prevent shipping damage. These must be field installed for tool-less operation. •High Static Drive - May include a belt, blower pulley, motor pulley or a motor change to enhance blower performance. Control Options •Simplicity® SE with Communication Option Control - The York® Simplicity® SE with Communication Option Control is factory installed. It includes all the features of the Simplicity® SE control with an additional gateway to BACnet MS/TP (programmable to Modbus or N2 protocols). Factory installed smoke detectors in the return air, may be subjected to freezing temperatures during “off” times due to out side air infiltration. These smoke detectors have an operational limit of 32°F to 131°F. Smoke detectors installed in areas that could be out side those limitations will have to be moved to prevent having false alarms. 251933-YTG-Y-0715 8 Johnson Controls Unitary Products •Novar® BAS Control - The Novar® building automation system controller is factory installed. Incudes supply air sensor, return air sensor, dirty filter indicator switch, and air proving switch. •CPC BAS Control - The Computer Process Controls Model 810-3060 ARTC Advanced Rooftop building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch and air proving switch. •Honeywell BAS Control - The Honeywell W7750C building automation system controller is factory installed. Includes air supply sensor, return air sensor, dirty filter indicator switch, and air proving switch. •York Commercial Comfort System (YCCS) - Provides rooftop system integration for YCCS single zone and change-over bypass systems. Field Installed Accessories NOTE: Simplicity Lite models are only available with a field installed Honeywell Jade economizer which is equipped standard with single enthalpy control (dual enthalpy available as field installed kit). Simplicity SE models are available with factory or field installed economizers including options for a SSE controlled economizer or an externally controlled BAS economizer where both feature standard dry bulb control (single and dual enthalpy available as field installed kits). •Economizers - All units offer a variety of optional field installed economizers that are shipped, installed and wired with AMCA 511 Licensed Class 1A low leak dampers designed to exceed ASHRAE 90.1-2010 and the International Energy Conservation Code (IECC) certification requirements by achieving leakage rates of 3 cfm/ sq. ft. at 1" of static pressure. Each economizer goes through a rigorous 60,000 cycle test. Dry bulb, single enthalpy, and dual enthalpy (with field installed kit) can be selected. All economizer options are fully integrated into the Simplicity SE controls. The economizer has spring return, fully modulating damper actuators and is capable of introducing up to 100% outdoor air. As the outdoor air intake dampers open, the return air dampers close. The changeover from mechanical refrigeration to economizer operation is regulated by the outdoor air dry bulb temperature or the outdoor air enthalpy input. The dual enthalpy kit provides a second input used to monitor the return air (field installed). The installer needs only to assemble the outdoor air hood, attach the enthalpy control the hood and mount the hood to the unit (Hood and control are provided). •Dry Bulb Economizer - Economizer operation is enabled by the outdoor air temperature being less than the setpoint of the economizer module. •Enthalpy Economizer - The added outdoor air enthalpy sensor enables economizer operation if the outdoor enthalpy is less than the setpoint of the economizer logic module. •Motorized Outdoor Air Intake Damper -Includes a slide- in / plug-in damper assembly with a 2-position, spring return motor actuator which opens to some pre-set position whenever the supply air blower is operating and will drive fully closed when the blower unit shuts down. The rain hood is painted to match the basic unit and must be field assembled before installing. •Electric Heaters - wired for single point power supply. These nickel chromium heater elements are provided with limit and automatic reset capability to prevent operation at excessive temperatures. •Roof Curbs - Eight and fourteen-inch high roof curbs provide a water-tight seal between the unit and the finished roof. These full perimeter curbs meet the requirements of the National Roofing Contractors Association (NRCA) and are shipped knocked-down for field assembly. Roof curbs are designed to fit inside the base rails of the unit and include both a wood nailing strip and duct hanger supports. •High Altitude Natural Gas - Burner orifices and pilot orifices are provided for proper furnace operation at altitudes up to 6,000 feet. •Propane - Burner orifices, pilot orifices and gas valve parts are provided to convert a natural gas furnace to propane. •High Altitude Propane - Burner orifices and pilot orifices are provided for proper furnace operation at altitudes up to 6,000 feet. This accessory supplements the basic propane conversion kit. •Low Nox Kit - Required to reduce the emission of nitrogen oxides below 40 nano grams per joule. •Power Exhaust - Our single input economizer options are available with power exhaust. Whenever the outdoor air intake dampers are opened for free cooling, the exhaust fan will be energized to prevent the conditioned space from being over-pressurized during economizer operation. The power exhaust option can only be used on bottom duct configurations. •Barometric Relief Damper - This damper accessory can be used to relieve internal building air pressure on units with an economizer without power exhaust. This accessory includes a rain hood, a bird screen and a fully assembled damper. With bottom duct connections, the damper should be mounted over the opening in the return air panel. With horizontal ductwork, the accessory should be mounted on the return air duct. •Enthalpy Accessory Control Kit - This kit contains the required components to convert a single enthalpy economizer to dual enthalpy. •Burglar Bars - Mount in the supply and return openings to prevent entry into the duct work. •Flue Exhaust Extension Kit - In locations with wind or weather conditions which may interfere with proper exhausting of furnace combustion products, this kit can be installed to prevent the flue exhaust from entering nearby fresh air intakes. •CO2 Sensor - Senses CO2 levels and automatically overrides the economizer when levels rise above the present limits. 251933-YTG-Y-0715 Johnson Controls Unitary Products 9 •Coil Guard - Customers can purchase a coil guard kit to protect the condenser coil from damage. This is not a hail guard kit. •Hail Guard - Hail Guard kit is available to prevent unit from hail damage. This is a sloped hood that fits above the coil. •Gas Piping Kit - This kit supplies all necessary fittings and shut off valve. Guide Specifications General Units shall be manufactured by Johnson Controls Unitary Products in an ISO 9001 certified facility. York's ZE/ZF/ZR/XN/XP units are convertible single package units. Although the units are primarily designed for curb mounting on a roof, they can also be slab-mounted at ground level or set on steel beams above a finished roof. Cooling only, cooling with gas heat and cooling with electric heat models are available with a wide variety of factory-mounted options and field-installed accessories to make them suitable for almost every application. All units are self-contained and assembled on full perimeter base rails with holes in the four corners for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to simplify the field installation and to provide years of dependable operation. All models (including those with an economizer) are suitable for either bottom or horizontal duct connections. Models with power exhaust are suitable for bottom duct connections only. For bottom duct, remove the sheet metal panels from the supply and return air openings through the base of the unit. For horizontal duct, remove the supply and return air panels on the rear of the unit. All non-Scroll compressors include crankcase heaters and all compressors have internal pressure relief. Every refrigerant circuit includes a liquid line filter-drier, a discharge line high pressure switch and a suction line with a freezestat and low pressure/loss of charge switch.The unit control circuit includes a 75 VA transformer, a 24-volt circuit breaker and a relay board with a compressor lockout circuit, a terminal strip for thermostat wiring, plus an additional set of pin connectors to simplify the interface of additional field controls. All models are CSA listed. All models include a 1-year limited warranty on the complete unit. Compressors and electric heater elements carry a 5-year warranty. Aluminized steel and Stainless steel tubular heat exchangers carry a 10-year warranty. Description Units shall be factory-assembled, single packaged, Electric Cooling/Gas Heat, Electric Cooling/Optional Electric Heat, Heat Pump/Optional Electric Heat and are designed for outdoor mounted installation. The 3 ton, 4 ton and 5 ton units shall have minimum SEER rating of 13.0 with heat pumps having a 7.7 H.S.P.F. The 6 Ton Cooling only or Cooling with Electric Heat shall have 11.2 EER, 6 Ton Cooling with Gas Heat shall have 11.0 EER. They shall have built-in field convertible duct connections for down discharge supply/return or horizontal discharge supply/return, and be available with factory installed options or field installed accessories. The units shall be factory wired, piped, charged with R-410A refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. All units the cooling performance shall be rated in accordance with DOE and AHRI test procedures. Units shall be CSA listed, classified to ANSI Z21.47, UL 1995/CSA No. 236 standards. Unit Cabinet Unit cabinet shall be constructed of galvanized steel, with exterior surfaces coated with a non-chalking, powdered paint finish, certified at 1000 hours salt spray test per ASTMB117 standards. Indoor blower section shall be insulated with a minimum 1/2” thick insulation, coated on the airside. Aluminum foil faced insulation shall be used in the furnace compartment and be fastened with ridged fasteners to prevent insulation from entering the air stream. Cabinet panels shall be “large” size, easily removable for servicing and maintenance. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging and proper sealing on roof curb applications. Disposable 1" filters shall be furnished and be accessible through a removable access door, sealed airtight. Units filter track shall be designed to accommodate either 1" or 2" filters. Fan performance measuring ports shall be provided on the outside of the cabinet to allow accurate air measurements of evaporator fan performance without removing panels or creating air by-pass of the coils. Condensate pan shall be internally sloped and conform to ASHRAE 62-89 self- draining standards. Condensate connection shall be a minimum of 3/4” I.D. female and be a ridged mount connection. Indoor (Evaporator) Fan Assembly The indoor fan shall be a factory installed direct-drive or belt- drive assembly that includes an adjustable pitch motor pulley. Job site selected brake horsepower (B.H.P.) shall not exceed the motors nameplate horsepower rating, plus the service factor. Units shall be designed not to operate above service factor. Fan wheel shall be double-inlet type with forward-curved blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant air volume. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. Outdoor (Condenser) Fan Assembly The outdoor fan shall be of the direct-drive propeller type, discharge air vertically, have aluminum blades riveted to a corrosion resistant steel spider bracket and shall be dynamically balanced for smooth operation. The outdoor fan motor shall be totally enclosed with permanently lubricated bearings, internally protected against overload conditions and staged independently. 251933-YTG-Y-0715 10 Johnson Controls Unitary Products Refrigerant Components Compressor: a. Shall be internally protected with internal high-pressure relief and over temperature protection. b. Shall have internal spring isolation and sound muffling to minimize vibration and noise, and be externally isolated on a dedicated, independent mounting. Coils: a. Evaporator coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed. Special Phenolic coating shall be available as a factory option. b. Evaporator coils shall be of the direct expansion, draw- thru design. c. Condenser coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed or Micro-Channel aluminum tube, aluminum fins. d. Condenser coils shall be of the direct expansion, draw- thru design. Refrigerant Circuit and Refrigerant Safety Components shall include: a. Independent, fixed-orifice, or thermally operated expansion devices. b. Filter drier/strainer to eliminate any moisture or foreign matter. c. Accessible service gage connections on both suction and liquid lines to charge, evacuate, and measure refrigerant pressure during any necessary servicing or troubleshooting, without losing charge. d. The refrigeration system shall provide at least 15°F of sub-cooling at design conditions. Unit Controls a. Unit shall be complete with self-contained low-voltage control circuit protected by a resettable circuit breaker on the 24-volt transformer side. b. Unit shall incorporate a lockout circuit which provides reset capability at the space thermostat or base unit, should any of the following standard safety devices trip and shut off compressor. c. Loss-of-charge/Low-pressure switch. d. High-pressure switch. e. Freeze-protection thermostat, evaporator coil. f. Unit shall incorporate “AUTO RESET” compressor over temperature, over current protection. g. Unit shall operate with conventional thermostat designs and have a low voltage terminal strip for easy hook-up. h. Unit control board shall have on-board diagnostics and fault code display. i. Standard controls shall include anti-short cycle and low voltage protection, and permit cooling operation down to 0°F. j. Control board shall monitor each refrigerant safety switch independently. k. Control board shall retain last 5 fault codes in non volatile memory which will not be lost in the event of a power loss. Gas Heating Section (Single Or 2 Stage) Shall be designed with induced draft combustion with post purge logic, energy saving direct spark ignition, and redundant main gas valve. Venter wheel shall be constructed of stainless steel for corrosion resistance. The heat exchanger shall be of the tubular type, constructed of T1-40 aluminized steel for corrosion resistance and allowing minimum mixed air entering temperature of 25°F. Burners shall be of the inshot type, constructed of aluminum coated steel and contain air mixture adjustments. All gas piping shall enter the unit cabinet at a single location through either the side or curb without any field modifications. Integrated control boards shall provide timed control of evaporator fan functioning and burner ignition. Heating section shall be provided with the following minimum protection: a. Primary and auxiliary high-temperature limit switches. b. Induced draft motor speed sensor. c. Flame roll out switch. d. Flame proving controls. e. If any of the above safety devices trip, a LED (light- emitting diode) indicator shall flash a diagnostic code that indicates which safety switch has tripped. NOTE: All 2 Stage Gas Heat, 60% Capacity 1st Stage, 40% Capacity 2nd Stage. Electric Heating Section An electric heating section, with nickel chromium elements, shall be provided in a range of 5 thru 30 KW, offering two stages of capacity - 16 KW and above on 208/230 volt heaters and 20 KW and above on 460 and 575 volt heaters. The heating section shall have a primary limit control(s) and automatic reset to prevent the heating element system from operating at an excessive temperature. The heating section assembly shall slide out of the unit for easy maintenance and service. Units with Electric Heating shall be wired for a single point power supply with branch circuit fusing (where required). Unit Operating Characteristics Unit shall be capable of starting and running at 125°F outdoor temperature, exceeding maximum load criteria of AHRI Standard 210/240. The compressor, with standard controls, shall be capable of operation down to 0°F outdoor temperature. Unit shall be provided with fan time delay to prevent cold air delivery before heat exchanger warms up (Gas heat only). 251933-YTG-Y-0715 Johnson Controls Unitary Products 11 Electrical Requirements All unit power wiring shall enter unit cabinet at a single factory provided location and be capable of side or bottom entry, to minimize roof penetrations and avoid unit field modifications. Separate side and bottom openings shall be provided for the control wiring. Standard Limited Warranties • Compressor 5 Years • Heat Exchanger 10 Years • Electric Heat Element 5 Years • Other Parts 1 Year Optional Outdoor Air Shall be made available by either/or: •Dry Bulb Automatic Economizer - Outdoor and return air dampers that are interlocked and positioned by a fully- modulating, spring-return damper actuator. The maximum leakage rate for the outdoor air intake dampers shall be designed to meet ASHRAE 90.1-2010, AMCA 511 Class 1A damper, and the International Energy Conservation Code (IECC) certification requirements by achieving leakage rates of 3 cfm/sq. ft. at 1" of static pressure. Changeover from compressor to economizer operation shall be provided by an integral electronic enthalpy control that feeds input into the basic module. The outdoor intake opening shall be covered with a rain hood that matches the exterior of the unit. Water eliminator/filters shall be provided. Simultaneous economizer/compressor operation is also possible. Dampers shall fully close on power loss. Available with barometric relief and power exhaust.. •Motorized Outdoor Air Dampers - Outdoor air dampers are positioned by a 2-position, spring-return damper actuator. A unit-mounted potentiometer shall be provided to adjust the outdoor damper assembly to take in the design CFM of outdoor air to meet the ventilation requirements of the conditioned space during normal operation. Whenever the indoor fan motor is energized, the dampers open up to one of two pre-selected positions - regardless of the outdoor air enthalpy. Dampers return to the fully closed position when the indoor fan motor is de- energized. Dampers shall fully close on power loss. Other Pre-engineered Accessories Available •Roof Curb - 14"and 8” high, full perimeter curb with wood nailer (shipped knocked-down). •Barometric Relief Damper - Contains a rain hood, air inlet screen, exhaust damper and mounting hardware. Used to relieve internal air pressure through the unit. •Propane Conversion Kit - Contains new orifices and gas valve parts to convert from natural to L.P. gas. One per unit required. •High Altitude - Natural Gas - Contains orifices required for applications between 2000 and 6000 feet altitude. •High Altitude - Propane Gas - Contains orifices required for applications between 2000 and 6000 feet altitude. Must be used with propane conversion kit. •Low Nox - Required to reduce the emission of nitrogen oxides below 40 nanograms per joule. •Gas Piping - Contains 1/2” pipe nipples, fittings and gas cock (including panel access gaskets) required for bottom gas supply connection with external shut off. •Power Exhaust Option - To work in conjunction with economizers. • Electric Heaters •Economizer/motorized Damper Rain Hood - Contains all hood panels and the hardware for assembling. • Manual Outdoor Air Damper •Coil Guard Kit - Guard for cooling coil. • Hail Guard • Flue Exhaust Extension OTHER FACTORY INSTALLED OPTIONS •Power Exhaust Option - To work in conjunction with economizers. • Stainless Steel Heat Exchanger • Stainless Steel Drain Pan • Bottom Drain Connection • Technicoat Phenolic Coated Condenser and Evaporator Coil • Electronic Single Enthalpy Economizer • Dirty Filter Switch • Phase Monitor • Coil Guard • Powered GFI Convenience Outlet • Non-powered GFI Convenience Outlet • BAS Controls - Simplicity® SE with BAS Communication (BACnet MS/TP, Modbus, and Johnson Controls N2) Option, CPC, HONEYWELL, NOVAR, YORK • Bas Ready Economizer (2-10 V.D.C. Actuator without a Controller) • Hinged Filter Door Access and Toolless Access Panels • 2" Pleated Filters, MERV 7 • Disconnect Switch • Supply Air Smoke Detector • Return Air Smoke Detector • Direct Drive or Belt Drive Blower with High Static Drive Option • Hot Gas Reheat with Hot Gas Bypass (Not available on 6 Ton) 251933-YTG-Y-0715 12 Johnson Controls Unitary Products Physical Data ZE036-060 Physical Data Component Models ZE036 ZE048 ZE060 Nominal Tonnage 3 4 5 ARI COOLING PERFORMANCE Gross Capacity @ AHRI A point (Btu) 36600 49100 59000 AHRI net capacity (Btu) 35500 47500 57000 EER 12.0 12.0 11.8 SEER 14.0 14.0 14.0 IPLV --- CFM 1200 1450 1680 System power (KW) 2.96 3.96 4.83 Refrigerant type R-410A R-410A R-410A Refrigerant charge (lb-oz) System 1 4-4 5-6 6-6 AHRI HEATING PERFORMANCE Heating model N04 N08 D06 D10 N06 N10 D06 D10 N08 N10 D06 D10 Heat input (K Btu) 50 100 75 115 75 125 75 125 100 125 75 125 Heat output (K Btu) 40 80 60.8 92 60 100 60.8 100.6 80 100 60.8 100.6 AFUE % 8181 - - 8181 - - 8181 - - Steady state efficiency (%) - - 81.1 80.2 - - 81.1 80.5 - - 81.1 80.5 No. burners 243535354535 No. stages 1 1 2 2 1 1 2 2 1 1 2 2 Temperature Rise Range (ºF) 15-45 45-75 35-70 55-90 25-70 45-75 25-70 45-75 25-55 35-75 20-55 35-75 Gas Limit Setting (ºF) - Direct Drive 240 170 210 200 210 165 210 165 170 165 210 165 Gas Limit Setting (ºF) - Belt Drive 240 210 240 200 240 210 240 210 210 210 210 210 Gas piping connection (in.) 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 DIMENSIONS (inches) Length 82 1/4 82 1/4 82 1/4 Width 44 7/8 44 7/8 44 7/8 Height 32 5/8 32 5/8 32 5/8 OPERATING WT. (lbs.)470 598 632 COMPRESSORS Type Scroll Scroll Scroll Quantity 1 1 1 Unit Capacity Steps (%) 100 100 100 CONDENSER COIL DATA Face area (Sq. Ft.) 16.3 16.3 16.3 Rows 111 Fins per inch 23 23 23 Tube diameter (in.) 0.71 / 18 0.71 / 18 1.00 / 25.4 Circuitry Type 2-pass Microchannel 2-pass Microchannel 2-pass Microchannel EVAPORATOR COIL DATA Face area (Sq. Ft.) 5.06 5.06 5.06 Rows 344 Fins per inch 13 13 13 Tube diameter 0.375 0.375 0.375 Circuitry Type Intertwined Intertwined Intertwined Refrigerant control Orifice Orifice TXV 251933-YTG-Y-0715 Johnson Controls Unitary Products 13 CONDENSER FAN DATA Quantity of fans 1 1 1 Fan diameter (Inch) 24 24 24 Type Prop Prop Prop Drive type Direct Direct Direct Quantity of motors 1 1 1 Motor HP each 1/2 1/2 1/2 1 No. speeds 1 1 1 RPM 1090 1090 1100 CFM 4000 4000 4200 BELT DRIVE EVAP FAN DATA Quantity 1 1 1 Fan Size (Inch) 11 x 10 11 x 10 11 x 10 Type Centrifugal Centrifugal Centrifugal Motor Sheave 1VL44 1VP56 1VL44 1VP56 1VL44 1VP56 Blower Sheave AK64 AK66 AK56 AK61 AK56 AK56 Belt A37 A39 A36 A38 A36 A38 Motor HP each 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 2 RPM 1740 1740 1740 Frame size 56 56 56 DIRECT DRIVE EVAP FAN DATA2 Quantity 1 1 1 Fan Size (Inch) 11 x 10 11 x 10 11 x 10 Type Centrifugal Centrifugal Centrifugal Motor HP each 3/4 1 1 RPM 1050 1050 1050 FILTERS 15" x 20" x 1" or 2" 2 2 2 14" x 25" x 1" or 2" 1 1 1 NOTE: All 2 Stage Gas Heat, 60% Capacity 1st Stage , 40% 2nd Stage 1. ECM O.D. Fan Motor 2. Only Available On 208/230 Volt Models ZE036-060 Physical Data (Continued) Component Models ZE036 ZE048 ZE060 Nominal Tonnage 3 4 5 251933-YTG-Y-0715 14 Johnson Controls Unitary Products ZF036-060 Physical Data Component Models ZF036 ZF048 ZF060 Nominal Tonnage 3.0 4.0 5.0 AHRI COOLING PERFORMANCE Gross Capacity @ AHRI A point (Btu)37000 49300 59000 AHRI net capacity (Btu)35500 47500 56500 EER 11.0 11.0 10.8 SEER 13.0 13.0 13.0 IPLV --- CFM 1200 1500 1750 System power (KW)3.23 4.32 5.23 Refrigerant type R-410A R-410A R-410A Refrigerant charge (lb-oz) System 1 4-4 5-8 5-8 AHRI HEATING PERFORMANCE Heating model N04 N08 D06 D10 N06 N10 D06 D10 N08 N10 D06 D10 Heat input (K Btu)50 100 75 115 75 125 75 125 100 125 75 125 Heat output (K Btu)40 80 60.8 92 60 100 60.8 100.6 80 100 60.8 100.6 AFUE %------------ Steady state efficiency (%)--80.0 80.0 --80.0 80.0 --80.0 80.0 No. burners 2 4 3 5 3 5 3 5 4 5 35 No. stages 1 1 2 2 1 1 2 2 1 1 22 Temperature Rise Range (ºF) 15-45 45-75 35-70 55-90 25-70 45-75 25-70 45-75 25-55 35-75 20-55 35-75 Gas Limit Setting (ºF) - Direct Drive 240 170 210 200 210 165 210 165 170 165 210 165 Gas Limit Setting (ºF) - Belt Drive 240 210 240 200 240 210 240 210 210 210 210 210 Gas piping connection (in.)1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 DIMENSIONS (inches) Length 82 1/4 82 1/4 82 1/4 Width 44 7/8 44 7/8 44 7/8 Height 32 5/8 32 5/8 32 5/8 OPERATING WT. (lbs.)468 541 569 COMPRESSORS Type Recip Recip Recip Quantity 1 1 1 Unit Capacity Steps (%)100 100 100 CONDENSER COIL DATA Face area (Sq. Ft.)16.3 16.3 16.3 Rows 1 1 1 Fins per inch 23 23 23 Tube diameter (in.)0.71 / 18 0.71 / 18 0.71 / 18 Circuitry Type 2-pass Microchannel 2-pass Microchannel 2-pass Microchannel EVAPORATOR COIL DATA Face area (Sq. Ft.)5.06 5.06 5.06 Rows 3 3 4 Fins per inch 13 13 13 Tube diameter 0.375 0.375 0.375 Circuitry Type Intertwined Intertwined Intertwined Refrigerant control Orifice Orifice Orifice 251933-YTG-Y-0715 Johnson Controls Unitary Products 15 CONDENSER FAN DATA Quantity 1 1 1 Fan diameter (Inch)24 24 24 Type Prop Prop Prop Drive type Direct Direct Direct Quantity of motors 1 1 1 Motor HP each 1/2 1/2 1/2 No. speeds 1 1 1 RPM 1090 1090 1090 CFM 3800 4200 4200 BELT DRIVE EVAP FAN DATA Quantity 1 1 1 Fan Size (Inch)11 x 10 11 x 10 11 x 10 Type Centrifugal Centrifugal Centrifugal Motor Sheave 1VL44 1VP56 1VL44 1VP56 1VL44 1VP56 Blower Sheave AK64 AK66 AK56 AK61 AK56 AK56 Belt A37 A39 A36 A38 A36 A38 Motor HP each 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 2 RPM 1725 1725 1725 Frame size 56 56 56 DIRECT DRIVE EVAP FAN DATA1 Quantity 1 1 1 Fan Size (Inch)11 x 10 11 x 10 11 x 10 Type Centrifugal Centrifugal Centrifugal Motor HP each 3/4 1 1 RPM 1050 1050 1050 FILTERS 15” x 20” x 1” or 2”2 2 2 14” x 25” x 1” or 2”1 1 1 NOTE: All 2 Stage Gas Heat, 60% Capacity 1st Stage, 40% Capacity 2nd Stage. 1. Only Available on 208/230-3-60 Models ZF036-060 Physical Data (Continued) Component Models ZF036 ZF048 ZF060 Nominal Tonnage 3.0 4.0 5.0 251933-YTG-Y-0715 16 Johnson Controls Unitary Products ZF072 Physical Data Component Models ZF072 Nominal Tonnage 6.0 AHRI COOLING PERFORMANCE Gross Capacity @ AHRI A point (Btu) 70360 AHRI net capacity (Btu) 68000 EER 11.2 1 / 11.02 IEER 11.3 CFM 2000 System power (KW) 6.07 Refrigerant type R-410A Refrigerant charge (lb-oz) System 1 6-4 AHRI HEATING PERFORMANCE Heating model N08 N10 D06 D10 Heat input (K Btu) 100 125 75 125 Heat output (K Btu) 80 100 60.8 100.6 AFUE % ---- Steady state efficiency (%) - - 80.0 80.0 No. burners 4535 No. stages 1122 Temperature Rise Range (ºF) 25-55 30-75 15-45 30-75 Gas Limit Setting (ºF) - Direct Drive 170 165 210 165 Gas Limit Setting (ºF) - Belt Drive 210 210 210 210 Gas piping connection (in.) 1/2 1/2 1/2 1/2 DIMENSIONS (inches) Length 82 1/4 Width 44 7/8 Height 32 5/8 OPERATING WT. (lbs.)640 COMPRESSORS Type Scroll Quantity 1 Unit Capacity Steps (%) 100 CONDENSER COIL DATA Face area (Sq. Ft.) 16.3 Rows 1 Fins per inch 23 Tube diameter (in.) 1.0 / 25.4 Circuitry Type 2-pass Microchannel EVAPORATOR COIL DATA Face area (Sq. Ft.) 5.06 Rows 4 Fins per inch 13 Tube diameter 0.375 Circuitry Type Intertwined Refrigerant control Fixed Orifice 251933-YTG-Y-0715 Johnson Controls Unitary Products 17 CONDENSER FAN DATA Quantity 1 Fan diameter (Inch) 24 Type Prop Drive type Direct No. speeds 1 Number of motors 1 Motor HP each 1/2 3 1/24 RPM 1100 1090 CFM 4200 4200 BELT DRIVE EVAP FAN DATA Quantity 1 Fan Size (Inch) 11 x 10 Type Centrifugal Motor Sheave 1VL44 1VP56 Blower Sheave AK56 AK56 Belt A36 A38 Motor HP each 1-1/2 3 RPM 1725 Frame size 56 DIRECT DRIVE EVAP FAN DATA5 Quantity 1 Fan Size (Inch) 11 x 10 Type Centrifugal Motor HP each 1 RPM 1050 FILTERS 15” x 20” x 1” or 2” 2 14” x 25” x 1” or 2” 1 NOTE:All 2 Stage Gas Heat, 60% Capacity 1st Stage, 40% Capacity 2nd Stage. 1. Cooling Only or Cooling with Electric Heat Unit 2. Cooling with Gas Heat Unit 3. Cooling Only or Cooling with Electric Heat Unit (ECM O.D. Fan Motor) 4. Cooling with Gas Heat Unit (PSC O.D. Fan Motor) 5. Only available On 208/230-3-60 Models ZF072 Physical Data (Continued) Component Models ZF072 Nominal Tonnage 6.0 251933-YTG-Y-0715 18 Johnson Controls Unitary Products ZR036-060 Physical Data Component Models ZR036 ZR048 ZR060 Nominal Tonnage 3.0 4.0 5.0 AHRI COOLING PERFORMANCE Gross Capacity @ AHRI A point (Btu) 36300 49600 60800 AHRI net capacity (Btu) 35000 48000 58500 EER 11.2 11.2 11.2 SEER 13.0 13.0 13.0 IPLV --- CFM 1200 1600 2000 System power (KW) 3.13 4.18 5.3 Refrigerant type R-410A R-410A R-410A Refrigerant charge (lb-oz) System 1 11-2 12-4 11-12 AHRI HEATING PERFORMANCE Heating model N04 N08 D06 D10 N06 N10 D06 D10 N08 N10 D06 D10 Heat input (K Btu) 50 100 75 115 75 125 75 125 100 125 75 125 Heat output (K Btu) 40 80 60.8 92 60 100 60.8 100.6 80 100 60.8 100.6 AFUE % ------------ Steady state efficiency (%) - - 80.0 80.0 - - 80.0 80.0 - - 80.0 80.0 No. burners 243535354535 No. stages 112211221122 Temperature Rise Range (ºF) 15-45 45-75 35-70 55-90 25-70 45-75 25-70 45-75 25-55 35-75 20-55 35-75 Gas Limit Setting (ºF) - Direct Drive 240 170 210 200 210 165 210 165 170 165 210 165 Gas Limit Setting (ºF) - Belt Drive 240 210 240 200 240 210 240 210 210 210 210 210 Gas piping connection (in.) 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 DIMENSIONS (inches) Length 82 1/4 82 1/4 82 1/4 Width 44 7/8 44 7/8 44 7/8 Height 32 5/8 32 5/8 32 5/8 OPERATING WT. (lbs.)575 585 590 COMPRESSORS Type Scroll Scroll Scroll Quantity 1 1 1 Unit Capacity Steps (%) 100 100 100 CONDENSER COIL DATA Face area (Sq. Ft.) 16.9 16.9 16.9 Rows 222 Fins per inch 18 18 18 Tube diameter (in.) 3/8 3/8 3/8 Circuitry Type Split-face Split-face Split-face EVAPORATOR COIL DATA Face area (Sq. Ft.) 5.06 5.06 5.06 Rows 334 Fins per inch 13 13 13 Tube diameter 0.375 0.375 0.375 Circuitry Type Split-face Split-face Split-face Refrigerant control TXV TXV TXV 251933-YTG-Y-0715 Johnson Controls Unitary Products 19 CONDENSER FAN DATA Quantity 1 1 1 Fan diameter (Inch) 24 24 24 Type Prop Prop Prop Drive type Direct Direct Direct No. speeds 1 1 1 Number of motors 1 1 1 Motor HP each 1/2 1/2 1/2 RPM 1090 1090 1090 CFM 4200 4200 4200 BELT DRIVE EVAP FAN DATA Quantity 1 1 1 Fan Size (Inch) 11 x 10 11 x 10 11 x 10 Type Centrifugal Centrifugal Centrifugal Motor Sheave 1VL44 1VP56 1VL44 1VP56 1VL44 1VP56 Blower Sheave AK64 AK66 AK56 AK61 AK56 AK56 Belt A37 A39 A36 A38 A36 A38 Motor HP each 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 2 RPM 1725 1725 1725 Frame size 56 56 56 DIRECT DRIVE EVAP FAN DATA1 Quantity 1 1 1 Fan Size (Inch) 11 x 10 11 x 10 11 x 10 Type Centrifugal Centrifugal Centrifugal Motor HP each 3/4 1 1 RPM 1050 1050 1050 FILTERS 15” x 20” x 1” or 2” 2 2 2 14” x 25” x 1” or 2” 1 1 1 NOTE: All 2 Stage Gas Heat, 60% Capacity 1st Stage, 40% Capacity 2nd Stage. 1. Only Available On 208/230-3-60 Models ZR036-060 Physical Data (Continued) Component Models ZR036 ZR048 ZR060 Nominal Tonnage 3.0 4.0 5.0 251933-YTG-Y-0715 20 Johnson Controls Unitary Products XN036-060 Physical Data Component Models XN036 XN048 XN060 Nominal Tonnage 3 4 5 AHRI COOLING PERFORMANCE Gross Capacity @ AHRI A point (Btu) 38,400 48,700 57,500 AHRI net capacity (MBH) 37,000 47,000 55,400 EER 12.0 11.8 11.0 SEER 14.0 14.0 14.0 CFM 1200 1450 1275/1850 System power (KW) 3.08 3.98 5.04 Refrigerant type R-410A R-410A R-410A Refrigerant charge (lb-oz) System 1 13-8 13-10 11-10 ARI HEATING PERFORMANCE 47ºF capacity rating (MBH) 36,000 44,000 51,500 System power (KW) / COP 3.15 (kW) / 3.35 4.03 (kW) / 3.20 4.5 (kW) / 3.35 17ºF capacity rating (MBH) 19,000 24,900 30,000 System power (KW) / COP 2.5 (kW) / 2.2 3.48 (kW) / 2.10 4.11 (kW) / 2.14 HSPF (Btu/Watts-hr) 8.00 8.00 8.00 DIMENSIONS (inches) Length 82-1/4 82-1/4 82-1/4 Width 44-7/8 44-7/8 44-7/8 Height 32-5/8 32-5/8 32-5/8 OPERATING WT. (lbs.)610 616 620 COMPRESSORS Type Scroll Scroll Scroll1 Quantity 1 1 1 CONDENSER COIL DATA Face area (Sq. Ft.) 16.88 16.88 16.88 Rows 2 2 2 Fins per inch 18 18 18 Tube diameter 3/8 3/8 3/8 Circuitry Type Split-face Split-face Split-face Refrigerant control TXV TXV TXV EVAPORATOR COIL DATA Face area (Sq. Ft.) 5.06 5.06 5.06 Rows 4 4 4 Fins per inch 13 13 13 Tube diameter 0.375 0.375 0.375 Circuitry Type Split-face Split-face Split-face Refrigerant control TXV TXV TXV 251933-YTG-Y-0715 Johnson Controls Unitary Products 21 CONDENSER FAN DATA Quantity 1 1 1 Fan diameter (Inch) 24 24 24 Type Prop Prop Prop Drive type Direct Direct Direct No. speeds 1 1 2 Number of motors 1 1 1 Motor HP each 1/4 1/4 2 1/22 RPM 850 850 850/1100 CFM 3000 3300 2800/3800 BELT DRIVE EVAP FAN DATA Quantity 1 1 1 Fan diameter (Inch) 11 x 10 11 x 10 11 x 10 Type Centrifugal Centrifugal Centrifugal Motor Sheave 1VL44 1VP56 1VL44 1VP56 1VL44 1VP56 Blower Sheave AK64 AK66 AK56 AK61 AK56 AK56 Belt A37 A39 A36 A38 A36 A38 Motor HP each 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 3 23 RPM 1740 1740 1740 Frame size 56 56 56 DIRECT DRIVE EVAP FAN DATA4 Quantity 1 1 1 Fan Size (Inch) 11 x 10 11 x 10 11 x 10 Type Centrifugal Centrifugal Centrifugal Motor HP each 3/4 1 1 RPM 1050 1050 1050 FILTERS 15" x 20" x 1" or 2" 2 2 2 14" x 25" x 1" or 2" 1 1 1 1. 2-Speed Scroll Compressor 2. ECM O. D. Fan Motor 3. I. D. Fan Motor with VFD 4. Only available On 208/230 Volt Models XN036-060 Physical Data (Continued) Component Models XN036 XN048 XN060 Nominal Tonnage 3 4 5 251933-YTG-Y-0715 22 Johnson Controls Unitary Products XP036-060 Physical Data Component Models XP036 XP048 XP060 Nominal Tonnage 3.0 4.0 5.0 AHRI COOLING PERFORMANCE Gross Capacity @ AHRI A point (Btu) 37,500 46500 60100 AHRI net capacity (Btu) 36,000 44500 57500 EER 11.4 11.0 10.6 SEER 13.0 13.0 13.0 CFM 1300 1600 1850 System power (KW) 3.30 4.05 5.42 Refrigerant type R-410A R-410A R-410A Refrigerant charge (lb-oz) 13-8 13-12 12-10 AHRI HEATING PERFORMANCE 47°F capacity rating (MBH) 35,000 41,000 56500 System power (KW) / COP 3.10 (kW) / 3.30 4.0 (kW) / 3.20 5.4 (kW) / 3.10 17°F capacity rating (MBH 21,200 22,400 34400 System power (KW) / COP 2.89(kW) / 2.15 3.8 (kW) / 2.10 4.75 (kW) / 2.10 HSPF (Btu/Watts-hr) 7.70 7.70 7.70 DIMENSIONS (inches) Length 82-1/4 82-1/4 82-1/4 Width 44-7/8 44-7/8 44-7/8 Height 32-5/8 32-5/8 32-5/8 OPERATING WT. (lbs.)575 585 590 COMPRESSORS Type Scroll Scroll Scroll Quantity 1 1 1 CONDENSER COIL DATA Face area (Sq. Ft.) 16.88 16.88 16.88 Rows 222 Fins per inch 18 18 18 Tube diameter 3/8 3/8 3/8 Circuitry Type Split-face Split-face Split-face EVAPORATOR COIL DATA Face area (Sq. Ft.) 5.06 5.06 5.06 Rows 444 Fins per inch 13 13 13 Tube diameter 0.375 0.375 0.375 Circuitry Type Split-face Split-face Split-face Refrigerant control TXV TXV TXV 251933-YTG-Y-0715 Johnson Controls Unitary Products 23 CONDENSER FAN DATA Quantity 1 1 1 Fan diameter (Inch) 24 24 24 Type Prop Prop Prop Drive type Direct Direct Direct No. speeds 1 1 1 Number of motors 1 1 1 Motor HP each 1/4 1/4 1/2 RPM 850 850 1090 Nominal total CFM 3275 3800 4200 BELT DRIVE EVAP FAN DATA Quantity 1 1 1 Fan Size (Inch) 11 x 10 11 x 10 11 x 10 Type Centrifugal Centrifugal Centrifugal Motor Sheave 1VL44 1VP56 1VL44 1VP56 1VL44 1VP56 Blower Sheave AK64 AK66 AK56 AK61 AK56 AK56 Belt A37 A39 A36 A38 A36 A38 Motor HP each 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 2 RPM 1725 1725 1725 Frame size 56 56 56 DIRECT DRIVE EVAP FAN DATA1 Quantity 1 1 1 Fan Size (Inch) 11 x 10 11 x 10 11 x 10 Type Centrifugal Centrifugal Centrifugal Motor HP each 3/4 1 1 RPM 1050 1050 1050 FILTERS 15” x 20” x 1” or 2” 2 2 2 14” x 25” x 1” or 2” 1 1 1 1. Only available On 208/230-3-60 Models XP036-060 Physical Data (Continued) Component Models XP036 XP048 XP060 Nominal Tonnage 3.0 4.0 5.0 251933-YTG-Y-0715 24 Johnson Controls Unitary Products ZF/ZR/XP036-072 Unit Limitations Size (Tons)Unit Voltage Unit Limitations Applied Voltage Outdoor DB Temp Min Max Max (°F) ZF/ZR/XP036 (3.0) 208/230-3-60 187 252 125 460-3-60 432 504 125 575-3-60 540 630 125 ZF/ZR/XP048 (4.0) 208/230-3-60 187 252 125 460-3-60 432 504 125 575-3-60 540 630 125 ZF/ZR/XP060 (5.0) 208/230-3-60 187 252 125 460-3-60 432 504 125 575-3-60 540 630 125 ZF072 (6.0) 208/230-3-60 187 252 125 460-3-60 432 504 125 575-3-60 540 630 125 ZE/XN036-060 Unit Limitations Size (Tons)Unit Voltage Unit Limitations Applied Voltage Outdoor DB Temp Min Max Max (°F) ZE/XN036 (3.0) 208/230-1-60 187 252 125 208/230-3-60 187 252 125 460-3-60 432 504 125 575-3-60 540 630 125 ZE/XN048 (4.0) 208/230-1-60 187 252 125 208/230-3-60 187 252 125 460-3-60 432 504 125 575-3-60 540 630 125 ZE/XN060 (5.0) 208/230-1-60 187 252 125 208/230-3-60 187 252 125 460-3-60 432 504 125 575-3-60 540 630 125 251933-YTG-Y-0715 Johnson Controls Unitary Products 67 Airflow Performance ZE036-060 Side Duct Application ZE036 (3 Ton Belt Drive) Side Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 4. Field Supplied Drive. 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option High Static Drive Option 800 634 0.28 735 0.34 828 0.40 914 0.47 995 0.55 1070 0.63 1140 0.72 1207 0.81 1270 0.90 1332 0.98 1000 659 0.34 760 0.40 853 0.46 939 0.53 1019 0.61 1094 0.69 1165 0.77 1232 0.87 1295 0.95 1356 1.05 1200 685 0.42 786 0.47 879 0.54 965 0.61 1045 0.69 1120 0.77 1191 0.86 1258 0.94 1321 1.04 1382 1.12 1400 716 0.53 816 0.58 909 0.65 995 0.72 1076 0.79 1151 0.88 1221 0.96 1288 1.05 1352 1.15 1413 1.23 1600 752 0.66 852 0.72 945 0.78 1032 0.86 1112 0.93 1187 1.02 1258 1.10 1324 1.19 1388 1.27 1449 1.37 FS4 ZE048 (4 Ton Belt Drive) Side Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 4. Field Supplied Drive. 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option High Static Drive Option 1000 703 0.27 786 0.42 866 0.49 942 0.58 1016 0.67 1087 0.76 1155 0.85 1221 0.96 1284 1.05 1345 1.16 1200 733 0.33 817 0.47 896 0.56 973 0.64 1047 0.73 1118 0.82 1186 0.92 1252 1.01 1315 1.11 1376 1.21 1400 770 0.42 853 0.56 933 0.63 1010 0.73 1083 0.81 1154 0.90 1222 1.00 1288 1.10 1352 1.19 1413 1.30 1600 811 0.55 895 0.67 974 0.76 1051 0.84 1125 0.94 1196 1.02 1264 1.12 1330 1.22 1393 1.32 1454 1.42 1800 857 0.73 940 0.84 1020 0.93 1097 1.01 1171 1.10 1242 1.19 1310 1.29 1375 1.38 1439 1.49 1500 1.59 2000 907 0.95 990 1.05 1070 1.14 1146 1.22 1220 1.31 1291 1.40 1359 1.50 1425 1.59 1488 1.70 1550 1.79 FS4 ZE060 (5 Ton Belt Drive) Side Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 4. Field Supplied Drive. 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option High Static Drive Option 1200 733 0.39 817 0.47 896 0.56 973 0.64 1047 0.73 1118 0.82 1186 0.92 1252 1.01 1315 1.11 1376 1.21 1400 770 0.47 853 0.56 933 0.63 1010 0.73 1083 0.81 1154 0.91 1222 1.00 1288 1.10 1352 1.19 1413 1.30 1600 811 0.60 895 0.67 974 0.76 1051 0.84 1125 0.94 1196 1.02 1264 1.12 1330 1.22 1393 1.32 1454 1.43 1800 857 0.77 940 0.84 1020 0.93 1097 1.01 1171 1.10 1242 1.19 1310 1.29 1375 1.38 1439 1.49 1500 1.60 2000 907 0.98 990 1.05 1070 1.14 1146 1.22 1220 1.31 1291 1.40 1359 1.50 1425 1.60 1488 1.70 1550 1.80 2200 960 1.23 1043 1.31 1123 1.39 1199 1.48 1273 1.56 1344 1.66 1412 1.75 1478 1.85 1541 1.96 1602 2.05 2400 1015 1.52 1099 1.61 1178 1.68 1255 1.76 1329 1.86 1400 1.96 1468 2.05 1534 2.15 1597 2.24 1658 2.35 2600 1074 1.86 1157 1.93 1237 2.02 1314 2.10 1387 2.19 1458 2.28 - - - - - - - - 251933-YTG-Y-0715 68 Johnson Controls Unitary Products ZF036-072 Side Duct Application ZE036 - 060 (3-5 Ton Direct Drive) Side Duct UNIT TONNAGE MOTOR1 SPEED 1. Factory set on medium speed tap. AVAILABLE EXTERNAL STATIC PRESSURE - IWG2 2. Includes allowances for a wet evaporator coil, 1” filters, and the heat exchangers. Refer to STATIC RESISTANCES Table for resistance values. 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S 33 3. Side Duct application (230 Volts) 5 (HI) 1574 320 1530 335 1488 349 1451 363 1411 376 1374 390 1331 403 1292 417 1249 430 4 (MED/HI) 1480 263 1433 276 1389 290 1347 303 1303 316 1257 329 1208 343 1153 358 1080 374 3 (MED) 1332 208 1286 221 1241 234 1195 246 1146 258 1097 272 1031 288 962 303 919 313 2 (MED/LOW) 1227 171 1178 183 1129 195 1076 207 1021 220 953 235 891 248 - - - - 1 (LOW) 1075 130 992 134 930 145 858 158 - - - - - - - - - - 43 5 (HI) - - 2067 696 2027 714 1991 734 1953 749 1910 764 1860 769 1770 743 1621 685 4 (MED/HI) 1913 539 1877 557 1839 571 1798 585 1764 602 1721 619 1677 638 1621 653 1545 639 3 (MED) 1722 408 1682 426 1634 438 1597 455 1554 472 1506 490 1450 505 1404 521 1370 536 2 (MED/LOW) 1475 321 1435 335 1388 352 1359 362 1319 376 1271 393 1220 411 1186 422 1142 437 1 (LOW) 1332 223 1290 237 1232 247 - - - - - - - - - - - - 53 5 (HI) 2245 883 2247 931 2236 950 2211 964 2171 979 2114 971 2034 940 1948 898 1855 854 4 (MED/HI) 2135 771 2116 784 2108 808 2078 826 2041 844 2004 859 1955 861 1886 843 1792 806 3 (MED) 2010 637 1989 656 1975 675 1938 696 1900 715 1867 730 1822 740 1784 756 1716 748 2 (MED/LOW) 1672 408 1633 426 1586 438 1550 455 1509 472 1462 490 1408 505 1363 521 1330 536 1 (LOW) 1562 327 1529 339 1491 356 - - - - - - - - - - - - ZF036 (3 Ton Belt Drive) Side Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 4. Field Supplied Drive. 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option High Static Drive Option 800 634 0.34 735 0.39 828 0.45 914 0.52 995 0.59 1070 0.67 1140 0.75 1207 0.83 1270 0.92 1332 1.00 1000 659 0.39 760 0.45 853 0.51 939 0.57 1019 0.65 1094 0.72 1165 0.80 1232 0.89 1295 0.97 1356 1.06 1200 685 0.47 786 0.52 879 0.58 965 0.65 1045 0.72 1120 0.80 1191 0.88 1258 0.96 1321 1.05 1382 1.13 1400 716 0.57 816 0.62 909 0.68 995 0.75 1076 0.82 1151 0.90 1221 0.98 1288 1.06 1352 1.15 1413 1.23 1600 752 0.69 852 0.75 945 0.81 1032 0.88 1112 0.95 1187 1.03 1258 1.11 1324 1.19 1388 1.27 1449 1.36 FS4 ZF048 (4 Ton Belt Drive) Side Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 4. Field Supplied Drive. 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option High Static Drive Option 1000 703 0.39 786 0.47 866 0.54 942 0.62 1016 0.71 1087 0.79 1155 0.88 1221 0.98 1284 1.07 1345 1.17 1200 733 0.44 817 0.52 896 0.60 973 0.68 1047 0.76 1118 0.85 1186 0.94 1252 1.03 1315 1.12 1376 1.22 1400 770 0.52 853 0.60 933 0.67 1010 0.76 1083 0.84 1154 0.93 1222 1.02 1288 1.11 1352 1.20 1413 1.30 1600 811 0.64 895 0.71 974 0.79 1051 0.87 1125 0.96 1196 1.04 1264 1.13 1330 1.23 1393 1.32 1454 1.42 1800 857 0.80 940 0.87 1020 0.95 1097 1.03 1171 1.11 1242 1.20 1310 1.29 1375 1.38 1439 1.48 1500 1.58 2000 907 1.00 990 1.07 1070 1.15 1146 1.23 1220 1.31 1291 1.40 1359 1.49 1425 1.58 1488 1.68 1550 1.77 FS4 251933-YTG-Y-0715 Johnson Controls Unitary Products 69 ZF060 (5 Ton Belt Drive) Side Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option High Static Drive Option 1200 733 0.44 817 0.52 896 0.60 973 0.68 1047 0.76 1118 0.85 1186 0.94 1252 1.03 1315 1.12 1376 1.22 1400 770 0.52 853 0.60 933 0.67 1010 0.76 1083 0.84 1154 0.93 1222 1.02 1288 1.11 1352 1.20 1413 1.30 1600 811 0.64 895 0.71 974 0.79 1051 0.87 1125 0.96 1196 1.04 1264 1.13 1330 1.23 1393 1.32 1454 1.42 1800 857 0.80 940 0.87 1020 0.95 1097 1.03 1171 1.11 1242 1.20 1310 1.29 1375 1.38 1439 1.48 1500 1.58 2000 907 1.00 990 1.07 1070 1.15 1146 1.23 1220 1.31 1291 1.40 1359 1.49 1425 1.58 1488 1.68 1550 1.77 2200 960 1.24 1043 1.31 1123 1.39 1199 1.47 1273 1.55 1344 1.64 1412 1.73 1478 1.82 1541 1.92 1602 2.01 2400 1015 1.51 1099 1.59 1178 1.66 1255 1.74 1329 1.83 1400 1.92 1468 2.01 1534 2.10 1597 2.19 1658 2.29 2600 1074 1.83 1157 1.90 1237 1.98 1314 2.06 1387 2.14 1458 2.23 - - - - - - - - ZF072 (6 Ton Belt Drive) - Side Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option High Static Drive Option 1600 811 0.64 895 0.71 974 0.79 1051 0.87 1125 0.96 1196 1.04 1264 1.13 1330 1.23 1393 1.32 1454 1.42 1800 857 0.80 940 0.87 1020 0.95 1097 1.03 1171 1.11 1242 1.20 1310 1.29 1375 1.38 1439 1.48 1500 1.58 2000 907 1.00 990 1.07 1070 1.15 1146 1.23 1220 1.31 1291 1.40 1359 1.49 1425 1.58 1488 1.68 1550 1.77 2200 960 1.24 1043 1.31 1123 1.39 1199 1.47 1273 1.55 1344 1.64 1412 1.73 1478 1.82 1541 1.92 1602 2.01 2400 1015 1.51 1099 1.59 1178 1.66 1255 1.74 1329 1.83 1400 1.92 1468 2.01 1534 2.10 1597 2.19 1658 2.29 2600 1074 1.83 1157 1.90 1237 1.98 1314 2.06 1387 2.14 1458 2.23 1526 2.32 1592 2.41 1656 2.51 1717 2.61 2800 1135 2.18 1218 2.25 1298 2.33 1375 2.41 1448 2.49 1519 2.58 1587 2.67 1653 2.76 1717 2.86 1778 2.96 3000 1198 2.56 1281 2.64 1361 2.71 1438 2.79 1511 2.88 1582 2.96 1651 3.05 1716 3.15 1780 3.24 - - Field Supplied Drive ZF036 - 072 (3-6 Ton Direct Drive) Side Duct UNIT TONNAGE MOTOR1 SPEED 1. Factory set on medium speed tap. AVAILABLE EXTERNAL STATIC PRESSURE - IWG2 2. Includes allowances for a wet evaporator coil, 1” filters, and the heat exchangers. Refer to STATIC RESISTANCES Table for resistance values. 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S 33 3. Side Duct application (230 Volts) 5 (HI) 1574 320 1530 335 1488 349 1451 363 1411 376 1374 390 1331 403 1292 417 1249 430 4 (MED/HI) 1480 263 1433 276 1389 290 1347 303 1303 316 1257 329 1208 343 1153 358 1080 374 3 (MED) 1332 208 1286 221 1241 234 1195 246 1146 258 1097 272 1031 288 962 303 919 313 2 (MED/LOW) 1227 171 1178 183 1129 195 1076 207 1021 220 953 235 891 248 - - - - 1 (LOW) 1075 130 992 134 930 145 858 158 - - - - - - - - - - 43 5 (HI) - - 2067 696 2027 714 1991 734 1953 749 1910 764 1860 769 1770 743 1621 685 4 (MED/HI) 1913 539 1877 557 1839 571 1798 585 1764 602 1721 619 1677 638 1621 653 1545 639 3 (MED) 1722 408 1682 426 1634 438 1597 455 1554 472 1506 490 1450 505 1404 521 1370 536 2 (MED/LOW) 1621 362 1580 380 1532 391 1502 406 1461 423 1411 440 1359 455 1324 469 1278 485 1 (LOW) 1332 223 1290 237 1232 247 - - - - - - - - - - - - 53 5 (HI) 2245 883 2247 931 2236 950 2211 964 2171 979 2114 971 2034 940 1948 898 1855 854 4 (MED/HI) 2135 771 2116 784 2108 808 2078 826 2041 844 2004 859 1955 861 1886 843 1792 806 3 (MED) 2010 637 1989 656 1975 675 1938 696 1900 715 1867 730 1822 740 1784 756 1716 748 2 (MED/LOW) 1748 413 1704 432 1669 451 1631 468 1589 479 1551 497 1513 513 1465 523 - - 1 (LOW) 1562 327 1529 339 1491 356 - - - - - - - - - - - - 63 5 (HI) 2256 883 2258 931 2247 950 2223 964 2182 979 2125 971 2044 940 1958 898 1864 854 4 (MED/HI) 2145 771 2127 784 2119 808 2089 826 2051 844 2014 859 1965 861 1896 843 1801 806 3 (MED) 2020 637 1999 656 1985 675 1947 696 1910 715 1876 730 1832 740 1793 756 - - 2 (MED/LOW)------------------ 1 (LOW) ------------------ 251933-YTG-Y-0715 70 Johnson Controls Unitary Products ZR036-060 Side Duct Application ZR036 (3 Ton Belt Drive) Side Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 4. Field Supplied Drive. 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option High Static Drive Option 800 634 0.34 735 0.39 828 0.45 914 0.52 995 0.59 1070 0.67 1140 0.75 1207 0.83 1270 0.92 1332 1.00 1000 659 0.39 760 0.45 853 0.51 939 0.57 1019 0.65 1094 0.72 1165 0.80 1232 0.89 1295 0.97 1356 1.06 1200 685 0.47 786 0.52 879 0.58 965 0.65 1045 0.72 1120 0.80 1191 0.88 1258 0.96 1321 1.05 1382 1.13 1400 716 0.57 816 0.62 909 0.68 995 0.75 1076 0.82 1151 0.90 1221 0.98 1288 1.06 1352 1.15 1413 1.23 1600 752 0.69 852 0.75 945 0.81 1032 0.88 1112 0.95 1187 1.03 1258 1.11 1324 1.19 1388 1.27 1449 1.36 FS4 ZR048 (4 Ton Belt Drive) Side Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 4. Field Supplied Drive. 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option High Static Drive Option 1000 703 0.39 786 0.47 866 0.54 942 0.62 1016 0.71 1087 0.79 1155 0.88 1221 0.98 1284 1.07 1345 1.17 1200 733 0.44 817 0.52 896 0.60 973 0.68 1047 0.76 1118 0.85 1186 0.94 1252 1.03 1315 1.12 1376 1.22 1400 770 0.52 853 0.60 933 0.67 1010 0.76 1083 0.84 1154 0.93 1222 1.02 1288 1.11 1352 1.20 1413 1.30 1600 811 0.64 895 0.71 974 0.79 1051 0.87 1125 0.96 1196 1.04 1264 1.13 1330 1.23 1393 1.32 1454 1.42 1800 857 0.80 940 0.87 1020 0.95 1097 1.03 1171 1.11 1242 1.20 1310 1.29 1375 1.38 1439 1.48 1500 1.58 2000 907 1.00 990 1.07 1070 1.15 1146 1.23 1220 1.31 1291 1.40 1359 1.49 1425 1.58 1488 1.68 1550 1.77 FS4 ZR060 (5 Ton Belt Drive) Side Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option High Static Drive Option 1200 733 0.44 817 0.52 896 0.60 973 0.68 1047 0.76 1118 0.85 1186 0.94 1252 1.03 1315 1.12 1376 1.22 1400 770 0.52 853 0.60 933 0.67 1010 0.76 1083 0.84 1154 0.93 1222 1.02 1288 1.11 1352 1.20 1413 1.30 1600 811 0.64 895 0.71 974 0.79 1051 0.87 1125 0.96 1196 1.04 1264 1.13 1330 1.23 1393 1.32 1454 1.42 1800 857 0.80 940 0.87 1020 0.95 1097 1.03 1171 1.11 1242 1.20 1310 1.29 1375 1.38 1439 1.48 1500 1.58 2000 907 1.00 990 1.07 1070 1.15 1146 1.23 1220 1.31 1291 1.40 1359 1.49 1425 1.58 1488 1.68 1550 1.77 2200 960 1.24 1043 1.31 1123 1.39 1199 1.47 1273 1.55 1344 1.64 1412 1.73 1478 1.82 1541 1.92 1602 2.01 2400 1015 1.51 1099 1.59 1178 1.66 1255 1.74 1329 1.83 1400 1.92 1468 2.01 1534 2.10 1597 2.19 1658 2.29 2600 1074 1.83 1157 1.90 1237 1.98 1314 2.06 1387 2.14 1458 2.23 - - - - - - - - 251933-YTG-Y-0715 Johnson Controls Unitary Products 71 ZE036-060 Bottom Duct Application ZR036 - 060 (3-5 Ton Direct Drive) Side Duct UNIT TONNAGE MOTOR1 SPEED 1. Factory set on medium speed tap. AVAILABLE EXTERNAL STATIC PRESSURE - IWG2 2. Includes allowances for a wet evaporator coil, 1” filters, and the heat exchangers. Refer to STATIC RESISTANCES Table for resistance values. 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S 33 3. Side Duct application (230 Volts) 5 (HI) 1574 320 1530 335 1488 349 1451 363 1411 376 1374 390 1331 403 1292 417 1249 430 4 (MED/HI) 1480 263 1433 276 1389 290 1347 303 1303 316 1257 329 1208 343 1153 358 1080 374 3 (MED) 1332 208 1286 221 1241 234 1195 246 1146 258 1097 272 1031 288 962 303 919 313 2 (MED/LOW) 1227 171 1178 183 1129 195 1076 207 1021 220 953 235 891 248 - - - - 1 (LOW) 1075 130 992 134 930 145 858 158 - - - - - - - - - - 43 5 (HI) - - 2067 696 2027 714 1991 734 1953 749 1910 764 1860 769 1770 743 1621 685 4 (MED/HI) 1913 539 1877 557 1839 571 1798 585 1764 602 1721 619 1677 638 1621 653 1545 639 3 (MED) 1722 408 1682 426 1634 438 1597 455 1554 472 1506 490 1450 505 1404 521 1370 536 2 (MED/LOW) 1621 362 1580 380 1532 391 1502 406 1461 423 1411 440 1359 455 1324 469 1278 485 1 (LOW) 1332 223 1290 237 1232 247 - - - - - - - - - - - - 53 5 (HI) 2245 883 2247 931 2236 950 2211 964 2171 979 2114 971 2034 940 1948 898 1855 854 4 (MED/HI) 2135 771 2116 784 2108 808 2078 826 2041 844 2004 859 1955 861 1886 843 1792 806 3 (MED) 2010 637 1989 656 1975 675 1938 696 1900 715 1867 730 1822 740 1784 756 1716 748 2 (MED/LOW) 1748 413 1704 432 1669 451 1631 468 1589 479 1551 497 1513 513 1465 523 - - 1 (LOW) 1562 327 1529 339 1491 356 - - - - - - - - - - - - ZE036 (3 Ton Belt Drive) Bottom Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option High Static Drive Option 800 613 0.29 724 0.34 826 0.41 920 0.48 1007 0.56 1089 0.63 1165 0.71 1237 0.80 1306 0.88 1372 0.98 1000 640 0.34 751 0.41 853 0.47 947 0.53 1034 0.61 1116 0.69 1192 0.77 1264 0.86 1333 0.95 1399 1.03 1200 669 0.43 779 0.48 881 0.55 975 0.61 1063 0.69 1144 0.77 1220 0.85 1293 0.94 1361 1.02 1427 1.12 1400 702 0.52 812 0.59 914 0.65 1009 0.71 1096 0.79 1177 0.87 1254 0.96 1326 1.04 1394 1.13 1460 1.21 1600 741 0.66 852 0.71 954 0.78 1048 0.85 1135 0.93 1217 1.00 1293 1.08 1365 1.17 1434 1.25 1500 1.35 FS4 ZE048 (4 Ton Belt Drive) Bottom Duct `Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option High Static Drive Option 1000 688 0.34 779 0.42 866 0.50 949 0.59 1029 0.67 1107 0.77 1181 0.85 1253 0.95 1322 1.05 1388 1.15 1200 722 0.40 812 0.48 899 0.56 983 0.64 1063 0.73 1140 0.82 1215 0.90 1286 1.01 1355 1.11 1422 1.20 1400 761 0.48 852 0.56 939 0.64 1022 0.73 1103 0.81 1180 0.89 1254 0.99 1326 1.08 1395 1.19 1462 1.29 1600 807 0.61 897 0.68 984 0.76 1068 0.84 1148 0.93 1225 1.02 1300 1.12 1371 1.21 1440 1.31 1507 1.40 1800 856 0.77 947 0.84 1034 0.93 1118 1.00 1198 1.10 1275 1.18 1349 1.28 1421 1.37 1490 1.47 1557 1.57 2000 910 0.97 1001 1.04 1088 1.13 1172 1.21 1252 1.30 1329 1.39 1403 1.48 1475 1.57 1544 1.68 1611 1.77 FS4 251933-YTG-Y-0715 72 Johnson Controls Unitary Products ZF036-072 Bottom Duct Application ZE060 (5 Ton Belt Drive) Bottom Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option High Static Drive Option 1200 722 0.40 812 0.48 899 0.56 983 0.64 1063 0.73 1140 0.82 1215 0.90 1286 1.01 1355 1.11 1422 1.20 1400 761 0.48 852 0.56 939 0.64 1022 0.73 1103 0.81 1180 0.89 1254 0.99 1326 1.08 1395 1.19 1462 1.29 1600 807 0.61 897 0.68 984 0.76 1068 0.84 1148 0.93 1225 1.02 1300 1.12 1371 1.21 1440 1.31 1507 1.40 1800 856 0.77 947 0.84 1034 0.93 1118 1.00 1198 1.10 1275 1.18 1349 1.28 1421 1.37 1490 1.47 1557 1.57 2000 910 0.97 1001 1.04 1088 1.13 1172 1.21 1252 1.30 1329 1.39 1403 1.48 1475 1.57 1544 1.68 1611 1.77 2200 968 1.22 1059 1.30 1146 1.37 1229 1.46 1309 1.54 1387 1.64 1461 1.73 1533 1.83 1602 1.92 1668 2.03 2400 1029 1.51 1119 1.58 1206 1.67 1290 1.74 1370 1.84 1448 1.92 1522 2.02 1593 2.11 1663 2.21 1729 2.31 2600 1093 1.84 1183 1.91 1270 1.98 1354 2.07 1434 2.15 1511 2.25 1586 2.34 - - - - - - FS4 ZE036 - 060 (3-5 Ton Direct Drive) Bottom Duct UNIT TONNAGE MOTOR1 SPEED 1. Factory set on medium speed tap. AVAILABLE EXTERNAL STATIC PRESSURE - IWG2 2. Includes allowances for a wet evaporator coil, 1” filters, and the heat exchangers. Refer to STATIC RESISTANCES Table for resistance values. 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S 33 3. Bottom Duct application (230 Volts) 5 (HI) 1520 320 1478 335 1438 349 1401 363 1363 376 1327 390 1286 403 1248 417 1207 430 4 (MED/HI) 1430 263 1384 276 1342 290 1302 303 1259 316 1215 329 1168 343 1114 358 1044 374 3 (MED) 1287 208 1242 221 1199 234 1155 246 1108 258 1060 272 997 288 930 303 889 313 2 (MED/LOW) 1185 171 1138 183 1091 195 1041 207 987 220 921 235 862 248 - - - - 1 (LOW) 1040 130 959 134 900 145 - - - - - - - - - - - - 43 5 (HI) - - 1995 696 1957 714 1922 734 1885 749 1844 764 1795 769 1709 743 1566 685 4 (MED/HI) 1846 539 1812 557 1776 571 1736 585 1704 602 1662 619 1619 638 1566 653 1492 639 3 (MED) 1662 408 1624 426 1577 438 1542 455 1501 472 1454 490 1400 505 1356 521 1323 536 2 (MED/LOW) 1566 362 1526 380 1480 391 1450 406 1411 423 1363 440 1312 455 1279 469 1235 485 1 (LOW) 1287 223 1246 237 1190 247 - - - - - - - - - - - - 53 5 (HI) 2166 883 2169 931 2158 950 2134 964 2095 979 2040 971 1963 940 1881 898 1791 854 4 (MED/HI) 2060 771 2042 784 2035 808 2006 826 1970 844 1934 859 1888 861 1821 843 1730 806 3 (MED) 1940 637 1920 656 1907 675 1870 696 1834 715 1802 730 1759 740 1722 756 1657 748 2 (MED/LOW) 1688 413 1645 432 1611 451 1575 468 1534 479 1498 497 1461 513 - - - - 1 (LOW) 1509 327 1477 339 - - - - - - - - - - - - - - ZF036 (3 Ton Belt Drive) Bottom Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option High Static Drive Option 800 613 0.35 724 0.40 826 0.46 920 0.53 1007 0.60 1089 0.67 1165 0.75 1237 0.83 1306 0.91 1372 1.00 1000 640 0.40 751 0.46 853 0.52 947 0.58 1034 0.65 1116 0.73 1192 0.80 1264 0.89 1333 0.97 1399 1.05 1200 669 0.48 779 0.53 881 0.59 975 0.65 1063 0.73 1144 0.80 1220 0.88 1293 0.96 1361 1.04 1427 1.13 1400 702 0.57 812 0.63 914 0.69 1009 0.75 1096 0.82 1177 0.90 1254 0.98 1326 1.06 1394 1.14 1460 1.22 1600 741 0.70 852 0.75 954 0.81 1048 0.88 1135 0.95 1217 1.02 1293 1.10 1365 1.18 1434 1.26 1500 1.35 Field Supplied Drive 251933-YTG-Y-0715 Johnson Controls Unitary Products 73 ZF048 (4 Ton Belt Drive) Bottom Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option High Static Drive Option 1000 688 0.40 779 0.47 866 0.55 949 0.63 1029 0.71 1107 0.80 1181 0.88 1253 0.97 1322 1.07 1388 1.16 1200 722 0.45 812 0.53 899 0.60 983 0.68 1063 0.76 1140 0.85 1215 0.93 1286 1.03 1355 1.12 1422 1.21 1400 761 0.53 852 0.60 939 0.68 1022 0.76 1103 0.84 1180 0.92 1254 1.01 1326 1.10 1395 1.20 1462 1.29 1600 807 0.65 897 0.72 984 0.79 1068 0.87 1148 0.95 1225 1.04 1300 1.13 1371 1.22 1440 1.31 1507 1.40 1800 856 0.80 947 0.87 1034 0.95 1118 1.02 1198 1.11 1275 1.19 1349 1.28 1421 1.37 1490 1.46 1557 1.56 2000 910 0.99 1001 1.06 1088 1.14 1172 1.22 1252 1.30 1329 1.39 1403 1.47 1475 1.56 1544 1.66 1611 1.75 Field Supplied Drive ZF060 (5 Ton Belt Drive) Bottom Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option High Static Drive Option 1200 722 0.45 812 0.53 899 0.60 983 0.68 1063 0.76 1140 0.85 1215 0.93 1286 1.03 1355 1.12 1422 1.21 1400 761 0.53 852 0.60 939 0.68 1022 0.76 1103 0.84 1180 0.92 1254 1.01 1326 1.10 1395 1.20 1462 1.29 1600 807 0.65 897 0.72 984 0.79 1068 0.87 1148 0.95 1225 1.04 1300 1.13 1371 1.22 1440 1.31 1507 1.40 1800 856 0.80 947 0.87 1034 0.95 1118 1.02 1198 1.11 1275 1.19 1349 1.28 1421 1.37 1490 1.46 1557 1.56 2000 910 0.99 1001 1.06 1088 1.14 1172 1.22 1252 1.30 1329 1.39 1403 1.47 1475 1.56 1544 1.66 1611 1.75 2200 968 1.23 1059 1.30 1146 1.37 1229 1.45 1309 1.53 1387 1.62 1461 1.71 1533 1.80 1602 1.89 1668 1.99 2400 1029 1.50 1119 1.57 1206 1.65 1290 1.72 1370 1.81 1448 1.89 1522 1.98 1593 2.07 1663 2.16 1729 2.26 2600 1093 1.81 1183 1.88 1270 1.95 1354 2.03 1434 2.11 1511 2.20 1586 2.29 ------ Field Supplied Drive ZF072 (6 Ton Belt Drive) Bottom Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option HIgh Static Drive Option 1600 807 0.65 897 0.72 984 0.79 1068 0.87 1148 0.95 1225 1.04 1300 1.13 1371 1.22 1440 1.31 1507 1.40 1800 856 0.80 947 0.87 1034 0.95 1118 1.02 1198 1.11 1275 1.19 1349 1.28 1421 1.37 1490 1.46 1557 1.56 2000 910 0.99 1001 1.06 1088 1.14 1172 1.22 1252 1.30 1329 1.39 1403 1.47 1475 1.56 1544 1.66 1611 1.75 2200 968 1.23 1059 1.30 1146 1.37 1229 1.45 1309 1.53 1387 1.62 1461 1.71 1533 1.80 1602 1.89 1668 1.99 2400 1029 1.50 1119 1.57 1206 1.65 1290 1.72 1370 1.81 1448 1.89 1522 1.98 1593 2.07 1663 2.16 1729 2.26 2600 1093 1.81 1183 1.88 1270 1.95 1354 2.03 1434 2.11 1511 2.20 1586 2.29 1657 2.38 1726 2.47 1793 2.57 2800 1159 2.15 1250 2.22 1337 2.29 1420 2.37 1500 2.46 1578 2.54 1652 2.63 1724 2.72 1793 2.81 - - 3000 1228 2.52 1318 2.59 1405 2.67 1489 2.75 1569 2.83 1646 2.91 1721 3.00 1792 3.09 - - - - Field Supplied Drive 251933-YTG-Y-0715 74 Johnson Controls Unitary Products ZR036-060 Bottom Duct Application ZF036 - 072 (3-6 Ton Direct Drive) Bottom Duct UNIT TONNAGE MOTOR1 SPEED 1. Factory set on medium speed tap. AVAILABLE EXTERNAL STATIC PRESSURE - IWG2 2. Includes allowances for a wet evaporator coil, 1” filters, and the heat exchangers. Refer to STATIC RESISTANCES Table for resistance values. 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S 33 3. Bottom Duct application (230 Volts) 5 (HI) 1520 320 1478 335 1438 349 1401 363 1363 376 1327 390 1286 403 1248 417 1207 430 4 (MED/HI) 1430 263 1384 276 1342 290 1302 303 1259 316 1215 329 1168 343 1114 358 1044 374 3 (MED) 1287 208 1242 221 1199 234 1155 246 1108 258 1060 272 997 288 930 303 889 313 2 (MED/LOW) 1185 171 1138 183 1091 195 1041 207 987 220 921 235 862 248 - - - - 1 (LOW) 1040 130 959 134 900 145 - - - - - - - - - - - - 43 5 (HI) - - 1995 696 1957 714 1922 734 1885 749 1844 764 1795 769 1709 743 1566 685 4 (MED/HI) 1846 539 1812 557 1776 571 1736 585 1704 602 1662 619 1619 638 1566 653 1492 639 3 (MED) 1662 408 1624 426 1577 438 1542 455 1501 472 1454 490 1400 505 1356 521 1323 536 2 (MED/LOW) 1566 362 1526 380 1480 391 1450 406 1411 423 1363 440 1312 455 1279 469 1235 485 1 (LOW) 1287 223 1246 237 1190 247 - - - - - - - - - - - - 53 5 (HI) 2166 883 2169 931 2158 950 2134 964 2095 979 2040 971 1963 940 1881 898 1791 854 4 (MED/HI) 2060 771 2042 784 2035 808 2006 826 1970 844 1934 859 1888 861 1821 843 1730 806 3 (MED) 1940 637 1920 656 1907 675 1870 696 1834 715 1802 730 1759 740 1722 756 1657 748 2 (MED/LOW) 1688 413 1645 432 1611 451 1575 468 1534 479 1498 497 1461 513 - - - - 1 (LOW) 1509 327 1477 339 - - - - - - - - - - - - - - 63 5 (HI) 2177 883 2179 931 2169 950 2145 964 2106 979 2051 971 1973 940 1890 898 1800 854 4 (MED/HI) 2071 771 2053 784 2045 808 2016 826 1980 844 1944 859 1897 861 1830 843 - - 3 (MED) 1950 637 1929 656 1916 675 1880 696 1844 715 1811 730 1768 740 - - - - 2 (MED/LOW)------------------ 1 (LOW) ------------------ ZR036 (3 Ton Belt Drive) Bottom Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option HIgh Static Drive Option 800 613 0.35 724 0.40 826 0.46 920 0.53 1007 0.60 1089 0.67 1165 0.75 1237 0.83 1306 0.91 1372 1.00 1000 640 0.40 751 0.46 853 0.52 947 0.58 1034 0.65 1116 0.73 1192 0.80 1264 0.89 1333 0.97 1399 1.05 1200 669 0.48 779 0.53 881 0.59 975 0.65 1063 0.73 1144 0.80 1220 0.88 1293 0.96 1361 1.04 1427 1.13 1400 702 0.57 812 0.63 914 0.69 1009 0.75 1096 0.82 1177 0.90 1254 0.98 1326 1.06 1394 1.14 1460 1.22 1600 741 0.70 852 0.75 954 0.81 1048 0.88 1135 0.95 1217 1.02 1293 1.10 1365 1.18 1434 1.26 1500 1.35 Field Supplied Drive ZR048 (4 Ton Belt Drive) Bottom Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option HIgh Static Drive Option 1000 688 0.40 779 0.47 866 0.55 949 0.63 1029 0.71 1107 0.80 1181 0.88 1253 0.97 1322 1.07 1388 1.16 1200 722 0.45 812 0.53 899 0.60 983 0.68 1063 0.76 1140 0.85 1215 0.93 1286 1.03 1355 1.12 1422 1.21 1400 761 0.53 852 0.60 939 0.68 1022 0.76 1103 0.84 1180 0.92 1254 1.01 1326 1.10 1395 1.20 1462 1.29 1600 807 0.65 897 0.72 984 0.79 1068 0.87 1148 0.95 1225 1.04 1300 1.13 1371 1.22 1440 1.31 1507 1.40 1800 856 0.80 947 0.87 1034 0.95 1118 1.02 1198 1.11 1275 1.19 1349 1.28 1421 1.37 1490 1.46 1557 1.56 2000 910 0.99 1001 1.06 1088 1.14 1172 1.22 1252 1.30 1329 1.39 1403 1.47 1475 1.56 1544 1.66 1611 1.75 Field Supplied Drive 251933-YTG-Y-0715 Johnson Controls Unitary Products 75 ZR060 (5 Ton Belt Drive) Bottom Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option HIgh Static Drive Option 1200 722 0.45 812 0.53 899 0.60 983 0.68 1063 0.76 1140 0.85 1215 0.93 1286 1.03 1355 1.12 1422 1.21 1400 761 0.53 852 0.60 939 0.68 1022 0.76 1103 0.84 1180 0.92 1254 1.01 1326 1.10 1395 1.20 1462 1.29 1600 807 0.65 897 0.72 984 0.79 1068 0.87 1148 0.95 1225 1.04 1300 1.13 1371 1.22 1440 1.31 1507 1.40 1800 856 0.80 947 0.87 1034 0.95 1118 1.02 1198 1.11 1275 1.19 1349 1.28 1421 1.37 1490 1.46 1557 1.56 2000 910 0.99 1001 1.06 1088 1.14 1172 1.22 1252 1.30 1329 1.39 1403 1.47 1475 1.56 1544 1.66 1611 1.75 2200 968 1.23 1059 1.30 1146 1.37 1229 1.45 1309 1.53 1387 1.62 1461 1.71 1533 1.80 1602 1.89 1668 1.99 2400 1029 1.50 1119 1.57 1206 1.65 1290 1.72 1370 1.81 1448 1.89 1522 1.98 1593 2.07 1663 2.16 1729 2.26 2600 1093 1.81 1183 1.88 1270 1.95 1354 2.03 1434 2.11 1511 2.20 1586 2.29 ------ Field Supplied Drive 251933-YTG-Y-0715 76 Johnson Controls Unitary Products XN036-060 Side Duct Application ZR036 - 060 (3-5 Ton Direct Drive) Bottom Duct UNIT TONNAGE MOTOR1 SPEED 1. Factory set on medium speed tap. AVAILABLE EXTERNAL STATIC PRESSURE - IWG2 2. Includes allowances for a wet evaporator coil, 1” filters, and the heat exchangers. Refer to STATIC RESISTANCES Table for resistance values. 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S 33 3. Bottom Duct application (230 Volts) 5 (HI) 1520 320 1478 335 1438 349 1401 363 1363 376 1327 390 1286 403 1248 417 1207 430 4 (MED/HI) 1430 263 1384 276 1342 290 1302 303 1259 316 1215 329 1168 343 1114 358 1044 374 3 (MED) 1287 208 1242 221 1199 234 1155 246 1108 258 1060 272 997 288 930 303 889 313 2 (MED/LOW) 1185 171 1138 183 1091 195 1041 207 987 220 921 235 862 248 - - - - 1 (LOW) 1040 130 959 134 900 145 - - - - - - - - - - - - 43 5 (HI) - - 1995 696 1957 714 1922 734 1885 749 1844 764 1795 769 1709 743 1566 685 4 (MED/HI) 1846 539 1812 557 1776 571 1736 585 1704 602 1662 619 1619 638 1566 653 1492 639 3 (MED) 1662 408 1624 426 1577 438 1542 455 1501 472 1454 490 1400 505 1356 521 1323 536 2 (MED/LOW) 1566 362 1526 380 1480 391 1450 406 1411 423 1363 440 1312 455 1279 469 1235 485 1 (LOW) 1287 223 1246 237 1190 247 - - - - - - - - - - - - 53 5 (HI) 2166 883 2169 931 2158 950 2134 964 2095 979 2040 971 1963 940 1881 898 1791 854 4 (MED/HI) 2060 771 2042 784 2035 808 2006 826 1970 844 1934 859 1888 861 1821 843 1730 806 3 (MED) 1940 637 1920 656 1907 675 1870 696 1834 715 1802 730 1759 740 1722 756 1657 748 2 (MED/LOW) 1688 413 1645 432 1611 451 1575 468 1534 479 1498 497 1461 513 - - - - 1 (LOW) 1509 327 1477 339 - - - - - - - - - - - - - - XN036 (3 Ton Belt Drive) Side Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 4. Field Supplied Drive. 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option High Static Drive Option 800 678 0.31 761 0.39 840 0.47 917 0.56 991 0.65 1062 0.74 1130 0.84 1195 0.94 1259 1.04 1320 1.16 1000 699 0.37 782 0.44 862 0.51 939 0.60 1012 0.69 1083 0.79 1151 0.88 1217 0.99 1280 1.10 1341 1.20 1200 727 0.40 810 0.47 889 0.56 966 0.64 1040 0.73 1110 0.82 1179 0.93 1244 1.02 1308 1.13 1369 1.23 1400 759 0.46 842 0.53 922 0.61 998 0.69 1072 0.79 1143 0.88 1211 0.98 1276 1.08 1340 1.19 1401 1.30 1600 795 0.56 878 0.63 958 0.70 1035 0.79 1108 0.88 1179 0.98 1247 1.07 1313 1.18 1376 1.28 1438 1.39 FS4 XN048 (4 Ton Belt Drive) Side Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 4. Field Supplied Drive. 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option High Drive 1000 699 0.37 782 0.44 862 0.51 939 0.60 1012 0.69 1083 0.79 1151 0.88 1217 0.99 1280 1.10 1341 1.20 1200 727 0.40 810 0.47 889 0.56 966 0.64 1040 0.73 1110 0.82 1179 0.93 1244 1.02 1308 1.13 1369 1.23 1400 759 0.46 842 0.53 922 0.61 998 0.69 1072 0.79 1143 0.88 1211 0.98 1276 1.08 1340 1.19 1401 1.30 1600 795 0.56 878 0.63 958 0.70 1035 0.79 1108 0.88 1179 0.98 1247 1.07 1313 1.18 1376 1.28 1438 1.39 1800 836 0.68 919 0.76 999 0.84 1075 0.93 1149 1.01 1220 1.11 1288 1.21 1353 1.31 1417 1.41 1478 1.52 2000 880 0.86 963 0.94 1042 1.02 1119 1.11 1193 1.19 1263 1.29 1331 1.39 1397 1.49 1460 1.59 1522 1.70 251933-YTG-Y-0715 Johnson Controls Unitary Products 77 XP036-060 Side Duct Application XN060 (5 Ton Belt Drive) Side Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 4. Field Supplied Drive. 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option High Static Drive 1200 727 0.40 810 0.47 889 0.56 966 0.64 1040 0.73 1110 0.82 1179 0.93 1244 1.02 1308 1.13 1369 1.23 1400 759 0.46 842 0.53 922 0.61 998 0.69 1072 0.79 1143 0.88 1211 0.98 1276 1.08 1340 1.19 1401 1.30 1600 795 0.56 878 0.63 958 0.70 1035 0.79 1108 0.88 1179 0.98 1247 1.07 1313 1.18 1376 1.28 1438 1.39 1800 836 0.68 919 0.76 999 0.84 1075 0.93 1149 1.01 1220 1.11 1288 1.21 1353 1.31 1417 1.41 1478 1.52 2000 880 0.86 963 0.94 1042 1.02 1119 1.11 1193 1.19 1263 1.29 1331 1.39 1397 1.49 1460 1.59 1522 1.70 2200 926 1.08 1009 1.16 1089 1.24 1166 1.33 1239 1.41 1310 1.51 1378 1.61 1444 1.71 1507 1.82 1568 1.92 2400 976 1.35 1059 1.42 1138 1.51 1215 1.59 1289 1.68 1359 1.77 1428 1.88 1493 1.97 1557 2.08 1618 2.19 2600 10281.6611111.7311901.8012671.9013401.9814112.0814792.1815452.2816082.39 - XN036 - 060 (3-5 Ton Direct Drive) Side Duct UNIT TONNAGE MOTOR1 SPEED AVAILABLE EXTERNAL STATIC PRESSURE - IWG2 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S 33 5 (HI) 1528 320 1485 335 1445 349 1409 363 1370 376 1334 390 1292 403 1254 417 1213 430 4 (MED/HI) 1437 263 1391 276 1349 290 1308 303 1265 316 1220 329 1173 343 1119 358 1048 374 3 (MED) 1293 208 1248 221 1205 234 1160 246 1113 258 1065 272 1001 288 934 303 892 313 2 (MED/LOW) 1191 171 1144 183 1096 195 1045 207 991 220 925 235 865 248 - - - - 1 (LOW) 1044 130 963 134 903 145 833 158 - - - - - - - - - - 43 5 (HI) - - 2007 696 1968 714 1933 734 1896 749 1855 764 1806 769 1719 743 1574 685 4 (MED/HI) 1857 539 1822 557 1786 571 1746 585 1713 602 1671 619 1628 638 1574 657 1500 676 3 (MED) 1672 408 1633 426 1586 438 1550 455 1509 472 1462 490 1408 505 1363 521 1330 536 2 (MED/LOW) 1475 321 1435 335 1388 352 1359 362 1319 376 1271 393 1220 411 1186 422 1142 437 1 (LOW) 1293 223 1252 237 1196 247 - - - - - - - - - - - - 53 5 (HI) 2245 883 2247 931 2236 950 2211 964 2171 979 2114 971 2034 940 1948 898 1855 854 4 (MED/HI) 2135 771 2116 784 2108 808 2078 826 2041 844 2004 859 1955 861 1886 843 1792 806 3 (MED) 2010 637 1989 656 1975 675 1938 696 1900 715 1867 730 1822 740 1784 756 1716 748 2 (MED/LOW) 1857 539 1822 557 1786 571 1746 585 1713 602 1671 619 1628 638 1574 657 1500 676 1 (LOW) 1293 223 1252 237 1196 247 - - - - - - - - - - - - 1. Factory set on medium speed tap. 2. Includes allowances for a wet evaporator coil and 1” filters. Refer to STATIC RESISTANCES Table for resistance values. 3. Side Duct application (230 Volts) XP036 (3 Ton Belt Drive) Side Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 4. Field Supplied Drive. 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option HIgh Static Drive Option 800 678 0.37 761 0.44 840 0.52 917 0.60 991 0.69 1062 0.77 1130 0.87 1195 0.96 1259 1.06 1320 1.17 1000 699 0.42 782 0.49 862 0.56 939 0.64 1012 0.73 1083 0.82 1151 0.91 1217 1.01 1280 1.11 1341 1.21 1200 727 0.45 810 0.52 889 0.60 966 0.68 1040 0.76 1110 0.85 1179 0.95 1244 1.04 1308 1.14 1369 1.24 1400 759 0.51 842 0.58 922 0.65 998 0.73 1072 0.82 1143 0.91 1211 1.00 1276 1.10 1340 1.20 1401 1.30 1600 795 0.60 878 0.67 958 0.74 1035 0.82 1108 0.91 1179 1.00 1247 1.09 1313 1.19 1376 1.28 1438 1.39 FS4 251933-YTG-Y-0715 78 Johnson Controls Unitary Products XP048 (4 Ton Belt Drive) Side Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option HIgh Static Drive Option 1000 699 0.42 782 0.49 862 0.56 939 0.64 1012 0.73 1083 0.82 1151 0.91 1217 1.01 1280 1.11 1341 1.21 1200 727 0.45 810 0.52 889 0.60 966 0.68 1040 0.76 1110 0.85 1179 0.95 1244 1.04 1308 1.14 1369 1.24 1400 759 0.51 842 0.58 922 0.65 998 0.73 1072 0.82 1143 0.91 1211 1.00 1276 1.10 1340 1.20 1401 1.30 1600 795 0.60 878 0.67 958 0.74 1035 0.82 1108 0.91 1179 1.00 1247 1.09 1313 1.19 1376 1.28 1438 1.39 1800 836 0.72 919 0.79 999 0.87 1075 0.95 1149 1.03 1220 1.12 1288 1.22 1353 1.31 1417 1.41 1478 1.51 2000 880 0.89 963 0.96 1042 1.04 1119 1.12 1193 1.20 1263 1.29 1331 1.39 1397 1.48 1460 1.58 1522 1.68 XP060 (5 Ton Belt Drive) Side Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option HIgh Static Drive Option 1200 727 0.45 810 0.52 889 0.60 966 0.68 1040 0.76 1110 0.85 1179 0.95 1244 1.04 1308 1.14 1369 1.24 1400 759 0.51 842 0.58 922 0.65 998 0.73 1072 0.82 1143 0.91 1211 1.00 1276 1.10 1340 1.20 1401 1.30 1600 795 0.60 878 0.67 958 0.74 1035 0.82 1108 0.91 1179 1.00 1247 1.09 1313 1.19 1376 1.28 1438 1.39 1800 836 0.72 919 0.79 999 0.87 1075 0.95 1149 1.03 1220 1.12 1288 1.22 1353 1.31 1417 1.41 1478 1.51 2000 880 0.89 963 0.96 1042 1.04 1119 1.12 1193 1.20 1263 1.29 1331 1.39 1397 1.48 1460 1.58 1522 1.68 2200 926 1.10 1009 1.17 1089 1.25 1166 1.33 1239 1.41 1310 1.50 1378 1.60 1444 1.69 1507 1.79 1568 1.89 2400 976 1.35 1059 1.42 1138 1.50 1215 1.58 1289 1.66 1359 1.75 1428 1.85 1493 1.94 1557 2.04 1618 2.14 2600 1028 1.64 1111 1.71 1190 1.78 1267 1.87 1340 1.95 1411 2.04 1479 2.13 1545 2.23 1608 2.33 - - XP036 - 060 (3-5 Ton Direct Drive) Side Duct UNITTONNAGE MOTOR1 SPEED 1. Factory set on medium speed tap. AVAILABLE EXTERNAL STATIC PRESSURE - IWG2 2. Includes allowances for a wet evaporator coil and 1” filters. Refer to STATIC RESISTANCES Table for resistance values. 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S 33 3. Side Duct application (230 Volts) 5 (HI) 1528 320 1485 335 1445 349 1409 363 1370 376 1334 390 1292 403 1254 417 1213 430 4 (MED/HI) 1437 263 1391 276 1349 290 1308 303 1265 316 1220 329 1173 343 1119 358 1048 374 3 (MED) 1293 208 1248 221 1205 234 1160 246 1113 258 1065 272 1001 288 934 303 892 313 2 (MED/LOW) 1191 171 1144 183 1096 195 1045 207 991 220 925 235 865 248 - - - - 1 (LOW) 1044 130 963 134 903 145 833 158 - - - - - - - - - - 43 5 (HI) - - 2007 696 1968 714 1933 734 1896 749 1855 764 1806 769 1719 743 1574 685 4 (MED/HI) 1857 539 1822 557 1786 571 1746 585 1713 602 1671 619 1628 638 1574 653 1500 639 3 (MED) 1672 408 1633 426 1586 438 1550 455 1509 472 1462 490 1408 505 1363 521 1330 536 2 (MED/LOW) 1574 362 1534 380 1487 391 1458 406 1418 423 1370 440 1319 455 1285 469 1241 485 1 (LOW) 1293 223 1252 237 1196 247 - - - - - - - - - - - - 53 5 (HI) 2245 883 2247 931 2236 950 2211 964 2171 979 2114 971 2034 940 1948 898 1855 854 4 (MED/HI) 2135 771 2116 784 2108 808 2078 826 2041 844 2004 859 1955 861 1886 843 1792 806 3 (MED) 2010 637 1989 656 1975 675 1938 696 1900 715 1867 730 1822 740 1784 756 1716 748 2 (MED/LOW) 1748 413 1704 432 1669 451 1631 468 1589 479 1551 497 1513 513 1465 523 - - 1 (LOW) 1562 327 1529 339 1491 356 - - - - - - - - - - - - 251933-YTG-Y-0715 Johnson Controls Unitary Products 79 XN036-060 Bottom Duct Application XN036 (3 Ton Belt Drive) Bottom Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option High Static Drive 800 661 0.33 751 0.40 838 0.48 922 0.57 1002 0.65 1079 0.75 1153 0.84 1225 0.94 1294 1.04 1361 1.15 1000 685 0.38 775 0.45 862 0.52 945 0.61 1025 0.69 1103 0.79 1177 0.88 1248 0.98 1317 1.08 1384 1.19 1200 714 0.41 805 0.48 892 0.56 975 0.64 1055 0.73 1132 0.82 1207 0.92 1278 1.02 1347 1.12 1414 1.22 1400 749 0.47 840 0.53 927 0.62 1010 0.70 1090 0.79 1167 0.88 1242 0.98 1313 1.07 1382 1.18 1449 1.29 1600 789 0.56 880 0.63 967 0.70 1050 0.79 1130 0.88 1207 0.97 1282 1.06 1353 1.17 1422 1.26 1489 1.37 FS4 XN048 (4 Ton Belt Drive) Bottom Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option High Static Drive 1200 714 0.41 805 0.48 892 0.56 975 0.64 1055 0.73 1132 0.82 1207 0.92 1278 1.02 1347 1.12 1414 1.22 1400 749 0.47 840 0.53 927 0.62 1010 0.70 1090 0.79 1167 0.88 1242 0.98 1313 1.07 1382 1.18 1449 1.29 1600 789 0.56 880 0.63 967 0.70 1050 0.79 1130 0.88 1207 0.97 1282 1.06 1353 1.17 1422 1.26 1489 1.37 1800 833 0.69 924 0.77 1011 0.84 1094 0.93 1174 1.01 1251 1.11 1326 1.20 1397 1.30 1466 1.40 1533 1.51 2000 881 0.86 971 0.94 1058 1.01 1142 1.10 1222 1.19 1299 1.28 1373 1.37 1445 1.48 1514 1.58 1580 1.68 FS4 XN060 (5 Ton Belt Drive) Bottom Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option High Static Drive 1200 714 0.41 805 0.48 892 0.56 975 0.64 1055 0.73 1132 0.82 1207 0.92 1278 1.02 1347 1.12 1414 1.22 1400 749 0.47 840 0.53 927 0.62 1010 0.70 1090 0.79 1167 0.88 1242 0.98 1313 1.07 1382 1.18 1449 1.29 1600 789 0.56 880 0.63 967 0.70 1050 0.79 1130 0.88 1207 0.97 1282 1.06 1353 1.17 1422 1.26 1489 1.37 1800 833 0.69 924 0.77 1011 0.84 1094 0.93 1174 1.01 1251 1.11 1326 1.20 1397 1.30 1466 1.40 1533 1.51 2000 881 0.86 971 0.94 1058 1.01 1142 1.10 1222 1.19 1299 1.28 1373 1.37 1445 1.48 1514 1.58 1580 1.68 2200 932 1.08 1022 1.16 1109 1.23 1193 1.32 1273 1.40 1350 1.50 1424 1.59 1496 1.69 1565 1.79 1631 1.90 2400 986 1.34 1076 1.41 1163 1.49 1246 1.57 1327 1.66 1404 1.75 1478 1.85 1550 1.95 1619 2.05 1685 2.15 2600 1042 1.64 1132 1.71 1219 1.78 1303 1.87 1383 1.95 1460 2.05 1534 2.14 1606 2.25 1675 2.34 FS4- 251933-YTG-Y-0715 80 Johnson Controls Unitary Products XP036-060 Bottom Duct Application XN036 - 060 (3-5 Ton Direct Drive) Bottom Duct UNIT TONNAGE MOTOR1 SPEED 1. Factory set on medium speed tap. AVAILABLE EXTERNAL STATIC PRESSURE - IWG2 2. Includes allowances for a wet evaporator coil and 1” filters. Refer to STATIC RESISTANCES Table for resistance values. 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S 33 3. Bottom Duct application (230 Volts) 5 (HI) 1476 320 1435 335 1396 349 1361 363 1324 376 1289 390 1249 403 1212 417 1172 430 4 (MED/HI) 1388 263 1344 276 1303 290 1264 303 1222 316 1179 329 1134 343 1082 358 1013 374 3 (MED) 1250 208 1206 221 1164 234 1121 246 1076 258 1029 272 968 288 903 303 863 313 2 (MED/LOW) 1151 171 1105 183 1060 195 1010 207 958 220 895 235 - - - - - - 1 (LOW) 1009 130 932 134 874 145 - - - - - - - - - - - - 43 5 (HI) 1975 636 1937 696 1900 714 1866 734 1831 749 1791 764 1743 769 1660 743 1520 685 4 (MED/HI) 1793 539 1759 557 1724 571 1685 585 1654 602 1613 619 1572 638 1520 657 1449 676 3 (MED) 1614 408 1577 426 1532 438 1497 455 1458 472 1412 490 1360 505 1317 521 1285 536 2 (MED/LOW) 1450 321 1384 335 1338 352 1311 362 1274 376 1226 393 1177 411 1144 422 1098 437 1 (LOW) 1250 223 1210 237 1156 247 - - - - - - - - - - - - 53 5 (HI) 2166 883 2169 931 2158 950 2134 964 2095 979 2040 971 1963 940 1881 898 1791 854 4 (MED/HI) 2060 771 2042 784 2035 808 2006 826 1970 844 1934 859 1888 861 1821 843 1730 806 3 (MED) 1940 637 1920 656 1907 675 1870 696 1834 715 1802 730 1759 740 1722 756 1657 748 2 (MED/LOW) 1830 413 1759 432 1724 451 1685 468 1654 479 1613 497 1572 513 - - - - 1 (LOW) 1250 327 1210 339 - - XP036 (3 Ton Belt Drive) Bottom Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option High Static Drive Option 800 661 0.39 751 0.45 838 0.53 922 0.61 1002 0.69 1079 0.78 1153 0.87 1225 0.96 1294 1.06 1361 1.16 1000 685 0.43 775 0.50 862 0.57 945 0.65 1025 0.73 1103 0.82 1177 0.91 1248 1.00 1317 1.10 1384 1.20 1200 714 0.46 805 0.53 892 0.60 975 0.68 1055 0.76 1132 0.85 1207 0.94 1278 1.04 1347 1.13 1414 1.23 1400 749 0.52 840 0.58 927 0.66 1010 0.74 1090 0.82 1167 0.91 1242 1.00 1313 1.09 1382 1.19 1449 1.29 1600 789 0.60 880 0.67 967 0.74 1050 0.82 1130 0.91 1207 0.99 1282 1.08 1353 1.18 1422 1.27 1489 1.37 Field Supplied Drive XP048 (4 Ton Belt Drive) Bottom Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 4. Field Supplied Drive. 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option High Static Drive Option 1000 685 0.43 775 0.50 862 0.57 945 0.65 1025 0.73 1103 0.82 1177 0.91 1248 1.00 1317 1.10 1384 1.20 1200 714 0.46 805 0.53 892 0.60 975 0.68 1055 0.76 1132 0.85 1207 0.94 1278 1.04 1347 1.13 1414 1.23 1400 749 0.52 840 0.58 927 0.66 1010 0.74 1090 0.82 1167 0.91 1242 1.00 1313 1.09 1382 1.19 1449 1.29 1600 789 0.60 880 0.67 967 0.74 1050 0.82 1130 0.91 1207 0.99 1282 1.08 1353 1.18 1422 1.27 1489 1.37 1800 833 0.73 924 0.80 1011 0.87 1094 0.95 1174 1.03 1251 1.12 1326 1.21 1397 1.30 1466 1.40 1533 1.50 2000 881 0.89 971 0.96 1058 1.03 1142 1.11 1222 1.20 1299 1.28 1373 1.37 1445 1.47 1514 1.57 1580 1.66 FS4 251933-YTG-Y-0715 Johnson Controls Unitary Products 81 XP060 (5 Ton Belt Drive) Bottom Duct Air Flow (CFM) Available External Static Pressure - IWG1 1. Blower performance includes 1” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option High Static Drive Option 1200 714 0.46 805 0.53 892 0.60 975 0.68 1055 0.76 1132 0.85 1207 0.94 1278 1.04 1347 1.13 1414 1.23 1400 749 0.52 840 0.58 927 0.66 1010 0.74 1090 0.82 1167 0.91 1242 1.00 1313 1.09 1382 1.19 1449 1.29 1600 789 0.60 880 0.67 967 0.74 1050 0.82 1130 0.91 1207 0.99 1282 1.08 1353 1.18 1422 1.27 1489 1.37 1800 833 0.73 924 0.80 1011 0.87 1094 0.95 1174 1.03 1251 1.12 1326 1.21 1397 1.30 1466 1.40 1533 1.50 2000 881 0.89 971 0.96 1058 1.03 1142 1.11 1222 1.20 1299 1.28 1373 1.37 1445 1.47 1514 1.57 1580 1.66 2200 932 1.10 1022 1.17 1109 1.24 1193 1.32 1273 1.40 1350 1.49 1424 1.58 1496 1.67 1565 1.77 1631 1.87 2400 986 1.34 1076 1.41 1163 1.48 1246 1.56 1327 1.64 1404 1.73 1478 1.82 1550 1.92 1619 2.01 1685 2.11 2600 1042 1.62 1132 1.69 1219 1.76 1303 1.84 1383 1.92 1460 2.01 1534 2.10 1606 2.20 1675 2.29 - - Field Supplied Drive XP036 - 060 (3-5 Ton Direct Drive) Bottom Duct UNIT TONNAGE MOTOR1 SPEED 1. Factory set on medium speed tap. AVAILABLE EXTERNAL STATIC PRESSURE - IWG2 2. Includes allowances for a wet evaporator coil and 1” filters. Refer to STATIC RESISTANCES Table for resistance values. 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S CF M W A T T S 33 3. Bottom Duct application (230 Volts) 5 (HI) 1476 320 1435 335 1396 349 1361 363 1324 376 1289 390 1249 403 1212 417 1172 430 4 (MED/HI) 1388 263 1344 276 1303 290 1264 303 1222 316 1179 329 1134 343 1082 358 1013 374 3 (MED) 1250 208 1206 221 1164 234 1121 246 1076 258 1029 272 968 288 903 303 863 313 2 (MED/LOW) 1151 171 1105 183 1060 195 1010 207 958 220 895 235 - - - - - - 1 (LOW) 1009 130 932 134 874 145 - - - - - - - - - - - - 43 5 (HI) 1975 636 1937 696 1900 714 1866 734 1831 749 1791 764 1743 769 1660 743 1520 685 4 (MED/HI) 1793 539 1759 557 1724 571 1685 585 1654 602 1613 619 1572 638 1520 653 1449 639 3 (MED) 1614 408 1577 426 1532 438 1497 455 1458 472 1412 490 1360 505 1317 521 1285 536 2 (MED/LOW) 1520 362 1481 380 1437 391 1408 406 1370 423 1324 440 1274 455 1242 469 1199 485 1 (LOW) 1250 223 1210 237 1156 247 - - - - - - - - - - - - 53 5 (HI) 2166 883 2169 931 2158 950 2134 964 2095 979 2040 971 1963 940 1881 898 1791 854 4 (MED/HI) 2060 771 2042 784 2035 808 2006 826 1970 844 1934 859 1888 861 1821 843 1730 806 3 (MED) 1940 637 1920 656 1907 675 1870 696 1834 715 1802 730 1759 740 1722 756 1657 748 2 (MED/LOW) 1688 413 1645 432 1611 451 1575 468 1534 479 1498 497 1461 513 - - - - 1 (LOW) 1509 327 1477 339 - - - - - - - - - - - - - - 251933-YTG-Y-0715 82 Johnson Controls Unitary Products Belt Drive RPM Selection Size (Tons)Model HP Max BHP Motor Sheave Blower Sheave 5 Turns Open 4 Turns Open 3 Turns Open 2 Turns Open 1 Turn Open Fully Closed 036 (3)ZE 1.5 1.73 1VL44 AK64 816 877 933 994 1049 1110 1.5 1.73 1VP56 AK66 1131 1186 1242 1298 1354 1409 048 (4)ZE 1.5 1.73 1VL44 AK56 943 1009 1075 1146 1212 1278 1.5 1.73 1VP56 AK61 1227 1288 1349 1409 1475 1536 060 (5)ZE 1.5 1.73 1VL44 AK56 943 1009 1075 1146 1212 1278 2 2.3 1VP56 AK56 1343 1414 1480 1546 1612 1683 036 (3)ZF/ZR 1.5 1.73 1VL44 AK64 805 865 920 980 1035 1095 1.5 1.73 1VP56 AK66 1115 1170 1225 1280 1335 1390 048 (4)ZF/ZR 1.5 1.73 1VL44 AK56 930 995 1060 1130 1195 1260 1.5 1.73 1VP56 AK61 1210 1270 1330 1390 1455 1515 060 (5)ZF/ZR 1.5 1.73 1VL44 AK56 930 995 1060 1130 1195 1260 2 2.3 1VP56 AK56 1325 1395 1460 1525 1590 1660 072 (6)ZF 1.5 1.73 1VL44 AK56 930 995 1060 1130 1195 1260 3 3.45 1VP56 AK56 1325 1395 1460 1525 1590 1660 036 (3)XN 1.5 1.73 1VL44 AK64 816 877 933 994 1049 1110 1.5 1.73 1VP56 AK66 1131 1186 1242 1298 1354 1409 048 (4)XN 1.5 1.73 1VL44 AK56 943 1009 1075 1146 1212 1278 1.5 1.73 1VP56 AK61 1227 1288 1349 1409 1475 1536 060 (5)XN 1.5 1.73 1VL44 AK56 943 1009 1075 1146 1212 1278 2 2.3 1VP56 AK56 1343 1414 1480 1546 1612 1683 036 (3)XP 1.5 1.73 1VL44 AK64 805 865 920 980 1035 1095 1.5 1.73 1VP56 AK66 1115 1170 1225 1280 1335 1390 048 (4)XP 1.5 1.73 1VL44 AK56 930 995 1060 1130 1195 1260 1.5 1.73 1VP56 AK61 1210 1270 1330 1390 1455 1515 060 (5)XP 1.5 1.73 1VL44 AK56 930 995 1060 1130 1195 1260 2 2.3 1VP56 AK56 1325 1395 1460 1525 1590 1660 Additional Static Resistance Size (Tons)CFM Cooling Only 1 1. Add these values to the available static resistance in the respective Blower Performance Tables (ZF, ZR Only). Economizer2 3 2. Deduct these values from the available external static pressure shown in the respective Blower Performance Tables. 3. The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. Electric Heat kW2 7 - 15 20 - 30 036 (3.0) 048 (4.0) 060 (5.0) 072 (6.0) 1000 0.08 0.07 0.04 0.06 1200 0.10 0.08 0.05 0.07 1400 0.12 0.09 0.06 0.08 1600 0.14 0.11 0.07 0.09 1800 0.16 0.13 0.08 0.11 2000 0.18 0.15 0.10 0.13 2200 0.20 0.17 0.12 0.15 2400 0.23 0.20 0.14 0.17 2600 0.26 0.23 0.16 0.20 2800 0.29 0.26 0.19 0.23 3000 0.32 0.30 0.22 0.26 251933-YTG-Y-0715 Johnson Controls Unitary Products 83 Drive Selection 1. Determine side or bottom supply air duct application. 2. Determine desired airflow. 3. Calculate or measure the amount of external static pressure. 4. Using the operating point determined from steps 1, 2 & 3, locate this point on the appropriate supply air blower performance table. (Linear interpolation may be necessary.) 5. Noting the RPM and BHP from step 4, locate the appropriate motor and/or drive on the RPM selection table. 6. Review the BHP compared to the motor options available. Select the appropriate motor and/or drive. 7. Review the RPM range for the motor options available. Select the appropriate drive if multiple drives are available for the chosen motor. 8. Determine turns open to obtain the desired operation point. Example 1. 2200 CFM 2. 1.6 iwg 3. Using the supply air blower performance table below, the following data point was located: 1478 RPM & 1.82 BHP. 4. Using the RPM selection table below, Size X and Model Y is found. 5. 1.82 BHP exceeds the maximum continuous BHP rating of the 1.5 HP motor. The 2 HP motor is required. 6. 1478 RPM is within the range of the 2 HP drive. 7. Using the 2 HP motor and drive, 2.5 turns open will achieve 1478 RPM. Example Supply Air Blower Performance Air Flow (CFM) Available External Static Pressure - IWG 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive Standard Drive Option HIgh Static Drive Option 2000 907 1.00 990 1.07 1070 1.15 1146 1.23 1220 1.31 1291 1.40 1359 1.49 1425 1.58 1488 1.68 1550 1.77 2200 960 1.24 1043 1.31 1123 1.39 1199 1.47 1273 1.55 1344 1.64 1412 1.73 1478 1.82 1541 1.92 1602 2.01 2400 1015 1.51 1099 1.59 1178 1.66 1255 1.74 1329 1.83 1400 1.92 1468 2.01 1534 2.10 1597 2.19 1658 2.29 2600 1074 1.83 1157 1.90 1237 1.98 1314 2.06 1387 2.14 1458 2.23 - - - - - - - - Table X: RPM Selection Size (Tons)Model HP Max BHP Motor Sheave Blower Sheave 5 Turns Open 4 Turns Open 3 Turns Open 2 Turns Open 1 Turn Open Fully Closed XY1.5 1.73 1VL44 AK56 930 995 1060 1130 1195 1260 2 2.3 1VP56 AK56 1325 1395 1460 1525 1590 1660 251933-YTG-Y-0715 84 Johnson Controls Unitary Products Altitude/Temperature Correction Factors Air Temp. Altitude (Ft.) 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 40 1.060 1.022 0.986 0.950 0.916 0.882 0.849 0.818 0.788 0.758 0.729 50 1.039 1.002 0.966 0.931 0.898 0.864 0.832 0.802 0.772 0.743 0.715 60 1.019 0.982 0.948 0.913 0.880 0.848 0.816 0.787 0.757 0.729 0.701 70 1.000 0.964 0.930 0.896 0.864 0.832 0.801 0.772 0.743 0.715 0.688 80 0.982 0.947 0.913 0.880 0.848 0.817 0.787 0.758 0.730 0.702 0.676 90 0.964 0.929 0.897 0.864 0.833 0.802 0.772 0.744 0.716 0.689 0.663 100 0.946 0.912 0.880 0.848 0.817 0.787 0.758 0.730 0.703 0.676 0.651 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000 1.050 1.100 40 50 60 70 80 90 100 Air Temperature (ºF) Co r r e c t i o n F a c t o r Sea Level 1000 ft 2000 ft 3000 ft 4000 ft 6000 ft 7000 ft 8000 ft 9000 ft 10000 ft 5000 ft 251933-YTG-Y-0715 Johnson Controls Unitary Products 85 Electric Heat Minimum Supply Air Size (Tons)Voltage Minimum Supply Air (CFM) Heater kW 5 7 10 15 20 30 036 (3.0) 208/230-1-60 900 900 900 900 900 - 208/230-3-60 900 900 900 900 900 - 460-3-60 - 900 900 900 900 - 600-3-60 - - 900 900 900 - 048 (4.0) 208/230-1-60 1200 1200 1200 1200 1200 - 208/230-3-60 1200 1200 1200 1200 1200 - 460-3-60 - 1200 1200 1200 1200 - 600-3-60 - - 1200 1200 1200 - 060 (5.0) 208/230-1-60 1500 1500 1500 1500 1500 1500 208/230-3-60 1500 1500 1500 1500 1500 1500 460-3-60 - 1500 1500 1500 1500 1500 600-3-60 - - 1500 1500 1500 1500 072 (6.0) 208/230-3-60 1500 1500 1500 1500 1500 1500 460-3-60 - 1500 1500 1500 1500 1500 600-3-60 - - 1500 1500 1500 1500 Indoor Blower Specifications (Belt Drive) Size (Tons) Motor Motor Sheave Blower Sheave BeltHP RPM Eff. SF Frame Datum Dia. (in.)Bore (in.) Model Datum Dia. (in.)Bore (in.) Model 036 (3.0) 1-1/2 1725 0.8 1.15 56 2.8 - 3.8 7/8 1VL44 6.0 1 AK64 A37 1-1/2 1725 0.8 1.15 56 4.0 - 5.0 7/8 1VP56 6.2 1 AK66 A39 048 (4.0) 1-1/2 1725 0.8 1.15 56 2.8 - 3.8 7/8 1VL44 5.2 1 AK56 A36 1-1/2 1725 0.8 1.15 56 4.0 - 5.0 7/8 1VP56 5.7 1 AK61 A38 060 (5.0) 1-1/2 1725 0.8 1.15 56 2.8 - 3.8 7/8 1VL44 5.2 1 AK56 A36 2 1725 0.8 1.15 56 4.0 - 5.0 7/8 1VP56 5.2 1 AK56 A38 072 (6.0) 1-1/2 1725 0.8 1.15 56 2.8 - 3.8 7/8 1VL44 5.2 1 AK56 A36 3 1725 0.8 1.15 56 4.0 - 5.0 7/8 1VP56 5.2 1 AK56 A38 Power Exhaust Specifications Model Voltage Motor Motor Fuse Size CFM @ 0.1 ESPHP RPM QTY LRA FLA MCA 2PE04703725 208/230-1-60 1/2 1725 1 1. Motors are multi-tapped and factory wired for high speed. 1 23.7 4.4 5.5 8 1350 2PE04703746 460-1-60 1/2 1725 1 1 4.1 1.7 2.1 5 1350 2PE04703758 575-3-60 1/2 1725 1 4.5 0.9 1.1 2 1350 Electric Heat Multipliers Voltage kW Capacity Multipliers1 1. Electric heaters are rated at nominal voltage. Use this table to determine the electric heat capacity for heaters applied at lower voltages. Nominal Applied 240 208 0.75 230 0.92 480 460 0.92 600 575 0.92 251933-YTG-Y-0715 86 Johnson Controls Unitary Products Sound Performance ZF/ZR/XP Indoor Sound Power Levels Size (Tons)CFM ESP (IWG) Blower Sound Power, dB (10-12) Watts Sound Rating1 dB (A) 1. These values have been accessed using a model of sound propagation from a point source into the hemispheric/free field. The dBA values provided are to be used for reference only. Calculation of dBA values cover matters of system design and the fan manufacture has no way of knowing the details of each system. This constitutes an exception to any specification or guarantee requiring a dBA value of sound data in any other form than sound power level ratings. Octave Band Centerline Frequency (Hz) RPM BHP 63 125 250 500 1000 2000 4000 8000 036 (3.0)1200 0.2 630 0.41 63 82 77 59 50 43 42 40 45 048 (4.0)1600 0.2 791 0.54 72 95 84 58 54 46 44 45 44 060 (5.0)2000 0.2 840 0.67 62 84 71 58 53 50 49 49 49 072 (6.0)2200 0.3 920 1.45 76 61 71 68 67 72 66 61 54 ZE/ZF/ZR Outdoor Sound Power Levels Size (Tons) Sound Rating1 dB (A) 1. Rated in accordance with AHRI 270 standard. Octave Band Centerline Frequency (Hz) 63 125 250 500 1000 2000 4000 8000 036 (3.0)81 87.5 86.0 81.0 77.0 75.0 69.5 65.5 70.5 048 (4.0)80 84.5 81.0 80.0 78.0 75.0 70.0 67.0 70.5 060 (5.0)82 86.5 87.5 81.5 77.5 75.0 71.5 68.0 70.5 072 (6.0)83 - 84.0 85.0 79.0 80.0 72.0 67.5 62.5 XN/XP Outdoor Sound Power Levels Size (Tons) Sound Rating1 dB (A) 1. Rated in accordance with AHRI 270 standard. Octave Band Centerline Frequency (Hz) 63 125 250 500 1000 2000 4000 8000 036 (3.0)76 83.5 84.5 76.5 72.0 68.0 66.0 60.0 56.0 048 (4.0)80 85.0 83.0 81.0 77.5 75.5 71.5 67.5 61.5 060 (5.0)80 86.0 84.0 81.0 77.0 75.5 71.0 66.5 60.5 251933-YTG-Y-0715 Johnson Controls Unitary Products 147 Weights and Dimensions ZE/ZF/ZR/XN/XP036-072 Unit Weights Unit 4 Point Load Weight Unit 6 Point Load Weight A D B Front C A F C B Front D E ZE036-060 Size (Tons) Weight (lbs.)Center of 4 point Load Location (lbs.)6 point Load Location (lbs.) Shipping Operating X Y A B C D A B C D E F 036 (3)475 470 34.5 18.25 111 80 117 162 78 62 51 74 91 114 048 (4)603 598 36 18.5 139 108 154 198 96 81 69 98 116 137 060 (5)637 632 37.5 18.2 139 117 171 204 96 85 76 111 124 140 ZF036-072 Size (Tons) Weight (lbs.) Center of Gravity 4 Point Load Location (lbs.) 6 Point Load Location (lbs.) ShippingOperatingX Y ABCDABCDEF 036 (3.0)473 468 33 18.25 114 76 111 166 81 61 48 70 89 119 048 (4.0)546 541 31.5 18.5 138 85 122 196 100 71 53 75 101 142 060 (5.0)574 569 37 15 105 86 170 208 72 63 55 110 125 144 072 (6.0)645 640 37 15 118 96 192 234 81 71 62 124 141 162 X Y LEFT FRONT 251933-YTG-Y-0715 148 Johnson Controls Unitary Products ZR036-060 Size (Tons) Weight (lbs.) Center of Gravity 4 Point Load Location (lbs.) 6 Point Load Location (lbs.) ShippingOperatingXYABCDABCDEF 036 (3.0)580 575 40 20 132 125 155 164 89 85 82 102 106 110 048 (4.0)590 585 40 20 134 127 158 167 90 87 84 104 108 112 060 (5.0)595 590 40 20 135 128 159 168 91 88 84 105 109 113 XN036-060 Size (Tons) Weight (lbs.)Center of Gravity 4 point Load Location (lbs.)6 point Load Location (lbs.) Shipping Operating X Y A B C D A B C D E F 036 (3)615 610 38.3 18.75 136 119 165 190 93 85 77 108 118 129 048 (4)621 616 38.2 18.4 135 117 169 195 92 84 76 110 121 133 060 (5)625 620 38.6 18 132 117 174 197 90 83 76 114 123 134 XP036-060 Size (Tons) Weight (lbs.) Center of Gravity 4 Point Load Location (lbs.) 6 Point Load Location (lbs.) ShippingOperatingXYABCDABCDEF 036 (3.0)580 575 39 20 135 121 151 168 91 85 80 99 106 114 048 (4.0)590 585 39 20 137 124 154 171 93 87 81 101 108 116 060 (5.0)595 590 39 20 138 125 155 172 94 87 82 102 109 117 ZE/ZF/ZR/XN/XP036-072 Unit Accessory Weights Unit Accessory Weight (lbs.) Shipping Operating Economizer 55 50 Power Exhaust 55 50 Electric Heat1 28 28 Gas Heat2 70 70 1. Weight given is for the maximum heater size available (30KW). 2. Weight given is for the maximum number of tube heat exchangers available (5 tube). 251933-YTG-Y-0715 Johnson Controls Unitary Products 149 ZE/ZF/ZR/XN/XP036-072 Unit Dimensions ZE/ZF/ZR036-072 Cooling Only/Electric Heat Front View XN/XP036-060 Heat Pump/Electric Heat Front View ZE/ZF/ZR036-072 Cooling Only/Gas Heat Front View 251933-YTG-Y-0715 150 Johnson Controls Unitary Products ZE/ZF/ZR/XN/XP036-072 Fixed Outdoor Air Motorized Damper Rain Hood ZE/ZF/ZR/XN/XP036-072 Rear View Detail “A” 27-1/2 27-1/2 1-5/8 19-1/2 44-7/8 19-3/4 Rear View Detail “B” Dimension “A” Fixed Outdoor Air Damper 12 16-1/2MotorizedDamper LH End View 27-1/2 27-1/2 7-1/4 “A”44-7/8 4-3/8 8-1/4 3-1/2 10-1/4 19-1/8 251933-YTG-Y-0715 Johnson Controls Unitary Products 151 ZR/ZF/ZR/XN/XP036-072 Disconnect Disconnect Switch Location and Motor Access Panel for Unit with “Belt-Drive” Option Control Box Access A,B Wiring Entry (See Detail “B”) Mounting Bracket for Disconnect Switch (Field Supplied) Field-Supplied Disconnect Switch Location Blower Motor Access Filter Access Dot Plugs ZE/ZF/ZR/XN/XP036-072 Utilities Entry Hole Opening Size (Dia.) Used For A7/8” KO1 1. Opening in the bottom to the unit can be located by the slice in the insulation. Control Wiring2 2. Do not remove the 2” knockout ring. Side Bottom B2” KO1Power Wiring Side Bottom C 1-5/8” KO Gas Piping (Front) D 1-1/2” KO Gas Piping (Bottom) ZE/ZF/ZR/XN/XP036-072 Minimum Clearances Location Clearance Front 24” (Cooling/Electric Heat) 32” (Gas Heat) Rear 12” (Less Economizer) 36” (With Economizer or Fixed Air/Motorized Damper) Left Side (Filter Access)24” (Less Economizer) 36” (With Economizer) Right Side (Cond. Coil) 24” Below Unit1 1. Units may be installed on combustible floors made from wood or class A, B, or C roof covering material. 0” Above Unit2 2. Units must be installed outdoors. Overhanging structures or shrubs should not obstruct condenser air discharge outlet. 72” (For Condenser Air Discharge) 3/4” X 1-1/4” WIDE GASKETING FOR CURB FRAME AND ALL DUCT SUPPORT SURFACES 2“ UNIT BASE WOOD NAILER 8“ MIN. ABOVE FINISHED ROOF CURB FRAME INSULATION UNIT BASE RAILS COUNTERFLASHING CAN’T STRIP INSULATION AND ROOFING MATERIAL ROOF DECK AND SUPPORT STRUCTURE 14” 3.56” 3.75” 251933-YTG-Y-0715 152 Johnson Controls Unitary Products ZE/ZF/ZR/XN/XP036-072 Roof Curb Cutaway 251933-YTG-Y-0715 Johnson Controls Unitary Products 153 ZE/ZF/ZR/XN/XP036-072 Roof Curb Dimensions Subject to change without notice. Printed in U.S.A. 251933-YTG-Y-0715 Copyright © 2015 by Johnson Controls, Inc. All rights reserved. Supersedes: 251933-YTG-X-0615 York International Corporation 5005 York Drive Norman, OK 73069 ZE/ZF/ZR/XN/XP036-072 Typical Applications APPENDIX F-4 Traffic Noise Calculations INPUT: ROADWAYS 14657 Dudek 21 October 2022 MG TNM 2.5 INPUT: ROADWAYS Average pavement type shall be used unless PROJECT/CONTRACT:14657 a State highway agency substantiates the use RUN:NWC SnaAna_Almond Ave Wrhs - Exist of a different type with the approval of FHWA Roadway Points Name Width Name No.Coordinates (pavement)Flow Control Segment X Y Z Control Speed Percent Pvmt On Device Constraint Vehicles Type Struct? Affected ft ft ft ft mph % Almond Ave 35.0 point1 1 234.2 65.3 0.00 Average point2 2 234.2 350.3 0.00 Santa Ana Ave 30.0 point3 3 -19.5 356.6 0.00 Average point4 4 228.9 356.6 0.00 Santa Ana Ave - e. of Almond 12.0 point5 5 237.1 357.4 0.00 Average point6 6 458.4 357.4 0.00 C:\TNM25\Projects\NWC Santa Ana_Almond Ave Warehouse PN 14657\Existing 1 21 October 2022 INPUT: TRAFFIC FOR LAeq1h Volumes 14657 Dudek 21 October 2022 MG TNM 2.5 INPUT: TRAFFIC FOR LAeq1h Volumes PROJECT/CONTRACT:14657 RUN:NWC SnaAna_Almond Ave Wrhs - Exist Roadway Points Name Name No.Segment Autos MTrucks HTrucks Buses Motorcycles V S V S V S V S V S veh/hr mph veh/hr mph veh/hr mph veh/hr mph veh/hr mph Almond Ave point1 1 152 30 15 30 47 25 0 0 0 0 point2 2 Santa Ana Ave point3 3 197 25 17 25 75 20 0 0 0 0 point4 4 Santa Ana Ave - e. of Almond point5 5 197 25 17 25 75 20 0 0 0 0 point6 6 C:\TNM25\Projects\NWC Santa Ana_Almond Ave Warehouse PN 14657\Existing 1 21 October 2022 INPUT: RECEIVERS 14657 Dudek 21 October 2022 MG TNM 2.5 INPUT: RECEIVERS PROJECT/CONTRACT:14657 RUN:NWC SnaAna_Almond Ave Wrhs - Exist Receiver Name No.#DUs Coordinates (ground)Height Input Sound Levels and Criteria Active X Y Z above Existing Impact Criteria NR in Ground LAeq1h LAeq1h Sub'l Goal Calc. ft ft ft ft dBA dBA dB dB ST3 - Santa Ana 1 1 331.4 382.2 0.00 5.00 0.00 66 10.0 8.0 Y ST1 - Almond 2 1 264.4 293.6 0.00 5.00 0.00 66 10.0 8.0 Y C:\TNM25\Projects\NWC Santa Ana_Almond Ave Warehouse PN 14657\Existing 1 21 October 2022 RESULTS: SOUND LEVELS 14657 Dudek 21 October 2022 MG TNM 2.5 Calculated with TNM 2.5 RESULTS: SOUND LEVELS PROJECT/CONTRACT: 14657 RUN: NWC SnaAna_Almond Ave Wrhs - Exist BARRIER DESIGN: INPUT HEIGHTS Average pavement type shall be used unless a State highway agency substantiates the use ATMOSPHERICS: 68 deg F, 50% RH of a different type with approval of FHWA. Receiver Name No.#DUs Existing No Barrier With Barrier LAeq1h LAeq1h Increase over existing Type Calculated Noise Reduction Calculated Crit'n Calculated Crit'n Impact LAeq1h Calculated Goal Calculated Sub'l Inc minus Goal dBA dBA dBA dB dB dBA dB dB dB ST3 - Santa Ana 1 1 0.0 67.5 66 67.5 10 Snd Lvl 67.5 0.0 8 -8.0 ST1 - Almond 2 1 0.0 66.2 66 66.2 10 Snd Lvl 66.2 0.0 8 -8.0 Dwelling Units # DUs Noise Reduction Min Avg Max dB dB dB All Selected 2 0.0 0.0 0.0 All Impacted 2 0.0 0.0 0.0 All that meet NR Goal 0 0.0 0.0 0.0 C:\TNM25\Projects\NWC Santa Ana_Almond Ave Warehouse PN 14657\Existing 1 21 October 2022 INPUT: ROADWAYS 14657 Dudek 21 October 2022 MG TNM 2.5 INPUT: ROADWAYS Average pavement type shall be used unless PROJECT/CONTRACT:14657 a State highway agency substantiates the use RUN:NWC SnaAna_AlmndAveWrhs - Ex w Prj of a different type with the approval of FHWA Roadway Points Name Width Name No.Coordinates (pavement)Flow Control Segment X Y Z Control Speed Percent Pvmt On Device Constraint Vehicles Type Struct? Affected ft ft ft ft mph % Almond Ave 35.0 point1 1 234.2 65.3 0.00 Average point2 2 234.2 350.3 0.00 Santa Ana Ave 30.0 point3 3 -19.5 356.6 0.00 Average point4 4 228.9 356.6 0.00 Santa Ana Ave - e. of Almond 12.0 point5 5 237.1 357.4 0.00 Average point6 6 458.4 357.4 0.00 C:\TNM25\Projects\NWC Santa Ana_Almond Ave Warehouse PN 14657\Existing w Proj 1 INPUT: TRAFFIC FOR LAeq1h Volumes 14657 Dudek 21 October 2022 MG TNM 2.5 INPUT: TRAFFIC FOR LAeq1h Volumes PROJECT/CONTRACT:14657 RUN:NWC SnaAna_AlmndAveWrhs - Ex w Prj Roadway Points Name Name No.Segment Autos MTrucks HTrucks Buses Motorcycles V S V S V S V S V S veh/hr mph veh/hr mph veh/hr mph veh/hr mph veh/hr mph Almond Ave point1 1 166 30 15 30 47 25 0 0 0 0 point2 2 Santa Ana Ave point3 3 201 25 17 25 83 20 0 0 0 0 point4 4 Santa Ana Ave - e. of Almond point5 5 201 25 17 25 83 20 0 0 0 0 point6 6 C:\TNM25\Projects\NWC Santa Ana_Almond Ave Warehouse PN 14657\Existing w Proj 1 INPUT: RECEIVERS 14657 Dudek 21 October 2022 MG TNM 2.5 INPUT: RECEIVERS PROJECT/CONTRACT:14657 RUN:NWC SnaAna_AlmndAveWrhs - Ex w Prj Receiver Name No.#DUs Coordinates (ground)Height Input Sound Levels and Criteria Active X Y Z above Existing Impact Criteria NR in Ground LAeq1h LAeq1h Sub'l Goal Calc. ft ft ft ft dBA dBA dB dB ST3 - Santa Ana 1 1 331.4 382.2 0.00 5.00 0.00 66 10.0 8.0 Y ST1 - Almond 2 1 264.4 293.6 0.00 5.00 0.00 66 10.0 8.0 Y C:\TNM25\Projects\NWC Santa Ana_Almond Ave Warehouse PN 14657\Existing w Proj 1 RESULTS: SOUND LEVELS 14657 Dudek 21 October 2022 MG TNM 2.5 Calculated with TNM 2.5 RESULTS: SOUND LEVELS PROJECT/CONTRACT: 14657 RUN: NWC SnaAna_AlmndAveWrhs - Ex w Prj BARRIER DESIGN: INPUT HEIGHTS Average pavement type shall be used unless a State highway agency substantiates the use ATMOSPHERICS: 68 deg F, 50% RH of a different type with approval of FHWA. Receiver Name No.#DUs Existing No Barrier With Barrier LAeq1h LAeq1h Increase over existing Type Calculated Noise Reduction Calculated Crit'n Calculated Crit'n Impact LAeq1h Calculated Goal Calculated Sub'l Inc minus Goal dBA dBA dBA dB dB dBA dB dB dB ST3 - Santa Ana 1 1 0.0 67.9 66 67.9 10 Snd Lvl 67.9 0.0 8 -8.0 ST1 - Almond 2 1 0.0 66.4 66 66.4 10 Snd Lvl 66.4 0.0 8 -8.0 Dwelling Units # DUs Noise Reduction Min Avg Max dB dB dB All Selected 2 0.0 0.0 0.0 All Impacted 2 0.0 0.0 0.0 All that meet NR Goal 0 0.0 0.0 0.0 C:\TNM25\Projects\NWC Santa Ana_Almond Ave Warehouse PN 14657\Existing w Proj 1