Loading...
HomeMy WebLinkAboutAppendix E - Energy Analysis Report Oleander & Santa Ana Avenue Warehouse ENERGY ANALYSIS CITY OF FONTANA PREPARED BY: Haseeb Qureshi hqureshi@urbanxroads.com Ali Dadabhoy adadabhoy@urbanxroads.com DECEMBER 2, 2022 14581-02 EA Report Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report i TABLE OF CONTENTS TABLE OF CONTENTS ............................................................................................................................. I APPENDICES ......................................................................................................................................... II LIST OF EXHIBITS .................................................................................................................................. II LIST OF TABLES .................................................................................................................................... II LIST OF ABBREVIATED TERMS ............................................................................................................. III EXECUTIVE SUMMARY .......................................................................................................................... 1 ES.1 Summary of Findings ..................................................................................................................... 1 ES.2 Project Requirements ................................................................................................................... 1 1 INTRODUCTION ........................................................................................................................... 3 1.1 Site Location .................................................................................................................................. 3 1.2 Project Description ........................................................................................................................ 3 2 EXISTING CONDITIONS ................................................................................................................ 7 2.1 Overview ....................................................................................................................................... 7 2.2 Electricity ....................................................................................................................................... 9 2.3 Natural Gas ................................................................................................................................. 11 2.4 Transportation Energy Resources ............................................................................................... 14 3 REGULATORY BACKGROUND ..................................................................................................... 17 3.1 Federal Regulations ..................................................................................................................... 17 3.2 California Regulations ................................................................................................................. 17 4 PROJECT ENERGY DEMANDS AND ENERGY EFFICIENCY MEASURES ........................................... 23 4.1 Evaluation Criteria ....................................................................................................................... 23 4.2 Methodology ............................................................................................................................... 23 4.3 Construction Energy Demands ................................................................................................... 24 4.4 Operational Energy Demands ..................................................................................................... 32 4.5 Summary ..................................................................................................................................... 33 5 CONCLUSIONS ........................................................................................................................... 37 6 REFERENCES .............................................................................................................................. 40 7 CERTIFICATIONS ........................................................................................................................ 43 Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report ii APPENDICES APPENDIX 4.1: CALEEMOD CONSTRUCTION EMISSIONS MODEL OUTPUTS APPENDIX 4.2: EMFAC2021 LIST OF EXHIBITS EXHIBIT 1-A: LOCATION MAP .............................................................................................................. 4 EXHIBIT 1-B: SITE PLAN........................................................................................................................ 5 LIST OF TABLES TABLE ES-1: SUMMARY OF CEQA SIGNIFICANCE FINDINGS .................................................................. 1 TABLE 2-1: TOTAL ELECRICITY SYSTEM POWER (CALIFORNIA 2020) ...................................................... 8 TABLE 2-2: SCE 2021 POWER CONTENT MIX ....................................................................................... 11 TABLE 4-1: CONSTRUCTION DURATION .............................................................................................. 24 TABLE 4-2: CONSTRUCTION POWER COST .......................................................................................... 25 TABLE 4-3: CONSTRUCTION ELECTRICITY USAGE ................................................................................ 25 TABLE 4-4: CONSTRUCTION EQUIPMENT ASSUMPTIONS .................................................................... 26 TABLE 4-5: CONSTRUCTION EQUIPMENT FUEL CONSUMPTION ESTIMATES ........................................ 27 TABLE 4-6: CONSTRUCTION TRIPS AND VMT ...................................................................................... 28 TABLE 4-7: CONSTRUCTION WORKER FUEL CONSUMPTION ESTIMATES ............................................. 29 TABLE 4-8: CONSTRUCTION VENDOR FUEL CONSUMPTION ESTIMATES (1 OF 3) ................................. 30 TABLE 4-9: TOTAL PROJECT-GENERATED TRAFFIC ANNUAL FUEL CONSUMPTION ............................... 32 TABLE 4-10: PROJECT ANNUAL OPERATIONAL NATURAL GAS DEMAND SUMMARY ........................... 33 Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report iii LIST OF ABBREVIATED TERMS % Percent (1) Reference AGSP Airport Gateway Specific Plan AQIA Oleander & Santa Ana Avenue Warehouse Air Quality Impact Analysis BACM Best Available Control Measures BTU British Thermal Units CalEEMod California Emissions Estimator Model CAPCOA California Air Pollution Control Officers Association CARB California Air Resources Board CCR California Code of Regulations CEC California Energy Commission CEQA California Environmental Quality Act City City of Fontana CPEP Clean Power and Electrification Pathway CPUC California Public Utilities Commission DMV Department of Motor Vehicles EIA Energy Information Administration EPA Environmental Protection Agency EMFAC EMissions FACtor FERC Federal Energy Regulatory Commission GHG Greenhouse Gas GWh Gigawatt Hour HHDT Heavy-Heavy Duty Trucks hp-hr-gal Horsepower Hours Per Gallon IEPR Integrated Energy Policy Report ISO Independent Service Operator ISTEA Intermodal Surface Transportation Efficiency Act ITE Institute of Transportation Engineers kBTU Thousand-British Thermal Units kWh Kilowatt Hour LDA Light Duty Auto LDT1/LDT2 Light-Duty Trucks LHDT1/LHDT2 Light-Heavy Duty Trucks MARB/IPA March Air Reserve Base/Inland Port Airport MDV Medium Duty Trucks Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report iv MHDT Medium-Heavy Duty Trucks MMcfd Million Cubic Feet Per Day mpg Miles Per Gallon MPO Metropolitan Planning Organization PG&E Pacific Gas and Electric Project Oleander & Santa Ana Avenue Warehouse PV Photovoltaic SCAB South Coast Air Basin SCE Southern California Edison SDAB San Diego Air Basin sf Square Feet SoCalGas Southern California Gas TEA-21 Transportation Equity Act for the 21st Century TRUs Transportation Refrigeration Units U.S. United States VMT Vehicle Miles Traveled Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report v This page intentionally left blank Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 1 EXECUTIVE SUMMARY ES.1 SUMMARY OF FINDINGS The results of this Oleander & Santa Ana Avenue Warehouse Energy Analysis is summarized below based on the significance criteria in Section 5 of this report consistent with Appendix G of the 2020 California Environmental Quality Act (CEQA) Statute and Guidelines (CEQA Guidelines) (1). Table ES-1 shows the findings of significance for potential energy impacts under CEQA. TABLE ES-1: SUMMARY OF CEQA SIGNIFICANCE FINDINGS Analysis Report Section Significance Findings Unmitigated Mitigated Energy Impact #1: Would the Project result in potentially significant environmental impact due to wasteful, inefficient, or unnecessary consumption of energy resources, during project construction or operation? 5.0 Less Than Significant n/a Energy Impact #2: Would the Project conflict with or obstruct a state or local plan for renewable energy or energy efficiency? 5.0 Less Than Significant n/a ES.2 PROJECT REQUIREMENTS The Project would be required to comply with regulations imposed by the federal and state agencies that regulate energy use and consumption through various means and programs. Those that are directly and indirectly applicable to the Project and that would assist in the reduction of energy usage include: • Intermodal Surface Transportation Efficiency Act of 1991 (ISTEA) • The Transportation Equity Act for the 21st Century (TEA-21 • Integrated Energy Policy Report (IEPR) • State of California Energy Plan • California Code Title 24, Part 6, Energy Efficiency Standards • California Code Title 24, Part 11, California Green Building Standards Code (CALGreen) • AB 1493 Pavley Regulations and Fuel Efficiency Standards • California’s Renewable Portfolio Standard (RPS) • Clean Energy and Pollution Reduction Act of 2015 (SB 350) Consistency with the above regulations is discussed in detail in section 5 of this report. Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 2 This page intentionally left blank Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 3 1 INTRODUCTION This report presents the results of the energy analysis prepared by Urban Crossroads, Inc., for the proposed Oleander & Santa Ana Avenue Warehouse Project (Project). The purpose of this report is to ensure that energy implication is considered by the City of Fontana (Lead Agency), as the lead agency, and to quantify anticipated energy usage associated with construction and operation of the proposed Project, determine if the usage amounts are efficient, typical, or wasteful for the land use type, and to emphasize avoiding or reducing inefficient, wasteful, and unnecessary consumption of energy. 1.1 SITE LOCATION The proposed project is located north of Santa Ana Avenue and on either side of Oleander Avenue as well as the northeast corner of Citrus Avenue at Santa Ana Avenue in the City of Fontana as shown on Exhibit 1-A. 1.2 PROJECT DESCRIPTION The proposed Project is to consist of the development of 540,849 square feet of warehouse use between 3 warehouse buildings: • Warehouse building 1: 151,618 square feet • Warehouse building 2: 196,336 square feet • Warehouse building 3: 192,895 square feet The Project is anticipated to be constructed by the year 2025. The preliminary site plan for the proposed Project is shown on Exhibit 1-B. This analysis is intended to describe energy usage associated with the expected operational activities at the Project site. This report assumes the Project will operate 24-hours daily for seven days per week. Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 4 EXHIBIT 1-A: LOCATION MAP Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 5 EXHIBIT 1-B: SITE PLAN Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 6 This page intentionally left blank Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 7 2 EXISTING CONDITIONS This section provides an overview of the existing energy conditions in the Project region. 2.1 OVERVIEW The most recent data for California’s estimated total energy consumption and natural gas consumption is from 2019, released by the United States (U.S.) Energy Information Administration’s (EIA) California State Profile and Energy Estimates in 2021 and included (2): • As of 2019, approximately 7,802 trillion British Thermal Unit (BTU) of energy was consumed • As of 2019, approximately 662 million barrels of petroleum • As of 2019, approximately 2,144 billion cubic feet of natural gas • As of 2019, approximately 1 million short tons of coal The California Energy Commission’s (CEC) Transportation Energy Demand Forecast 2018-2030 was released in order to support the 2017 Integrated Energy Policy Report. The Transportation energy Demand Forecast 2018-2030 lays out graphs and data supporting their projections of California’s future transportation energy demand. The projected inputs consider expected variable changes in fuel prices, income, population, and other variables. Predictions regarding fuel demand included: • Gasoline demand in the transportation sector is expected to decline from approximately 15.8 billion gallons in 2017 to between 12.3 billion and 12.7 billion gallons in 2030 (3) • Diesel demand in the transportation sector is expected to rise, increasing from approximately 3.7 billion diesel gallons in 2015 to approximately 4.7 billion in 2030 (3) • Data from the Department of Energy states that approximately 3.9 billion gallons of diesel fuel were consumed in 2019 (4) The most recent data provided by the EIA for energy use in California by demand sector is from 2019 and is reported as follows: • Approximately 39.4% transportation; • Approximately 23.1% industrial; • Approximately 18.7% residential; and • Approximately 18.8% commercial (5) In 2020, total system electric generation for California was 272,576 gigawatt hours (GWh). California's massive electricity in-state generation system generated approximately 190,913 GWh which accounted for approximately 70% of the electricity it uses; the rest was imported from the Pacific Northwest (15%) and the U.S. Southwest (15%) (6). Natural gas is the main source for electricity generation at 42.97% of the total in-state electric generation system power as shown in Table 2-1. Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 8 TABLE 2-1: TOTAL ELECRICITY SYSTEM POWER (CALIFORNIA 2020) Fuel Type California In-State Generation (GWh) Percent of California In-State Generation Northwest Imports (GWh) Southwest Imports (GWh) Total Imports (GWh) Percent of Imports Total California Energy Mix () Total California Power Mix Coal 317 0.17% 194 6,963 7,157 8.76% 7,474 2.74% Natural Gas 92,298 48.35% 70 8,654 8,724 10.68% 101,022 37.06% Oil 30 0.02% - - 0 0.00% 30 0.01% Other (Waste Heat/Petroleum Coke) 384 0.20% 125 9 134 0.16% 518 0.19% Nuclear 16,280 8.53% 672 8,481 9,154 11.21% 25,434 9.33% Large Hydro 17,938 9.40% 14,078 1,259 15,337 18.78% 33,275 12.21% Unspecified - 0.00% 12,870 1,745 14,615 17.90% 14,615 5.36% Non-Renewable and Unspecified Totals 127,248 66.65% 28,009 27,111 55,120 67.50% 182,368 66.91% Biomass 5,680 2.97% 975 25 1,000 1.22% 6,679 2.45% Geothermal 11,345 5.94% 166 1,825 1,991 2.44% 13,336 4.89% Small Hydro 3,476 1.82% 320 2 322 0.39% 3,798 1.39% Solar 29,456 15.43% 284 6,312 6,596 8.08% 36,052 13.23% Wind 13,708 7.18% 11,438 5,197 16,635 20.37% 30,343 11.13% Renewable Totals 63,665 33.35% 13,184 13,359 26,543 32.50% 90,208 33.09% System Totals 190,913 100.00% 41,193 40,471 81,663 100.00% 272,576 100.00% Source: California Energy Commission’s 2020 Total System Electric Generation Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 9 An updated summary of, and context for energy consumption and energy demands within the State is presented in “U.S. Energy Information Administration, California State Profile and Energy Estimates, Quick Facts” excerpted below (7): • California was the seventh-largest producer of crude oil among the 50 states in 2019, and, as of January 2020, it ranked third in oil refining capacity. Foreign suppliers, led by Saudi Arabia, Iraq, Ecuador, and Colombia, provided more than half of the crude oil refined in California in 2019. • California is the largest consumer of both jet fuel and motor gasoline among the 50 states and accounted for 17% of the nation’s jet fuel consumption and 11% of motor gasoline consumption in 2019. The state is the second-largest consumer of all petroleum products combined, accounting for 10% of the U.S. total. In 2018, California’s energy consumption was the second highest among the states, but its per capita energy consumption was the fourth-lowest due in part to its mild climate and its energy efficiency programs. • In 2019, California was the nation’s top producer of electricity from solar, geothermal, and biomass energy and the state was second in the nation in conventional hydroelectric power generation. • In 2019, California was the fourth largest electricity producer in the nation, but the state was also the nation’s largest importer of electricity and received about 28% of its electricity supply from generating facilities outside of California, including imports from Mexico. As indicated above, California is one of the nation’s leading energy-producing states, and California’s per capita energy use is among the nation’s most efficient. Given the nature of the Project, the remainder of this discussion will focus on the three sources of energy that are most relevant to the project—namely, electricity, natural gas, and transportation fuel for vehicle trips associated with the uses planned for the Project. 2.2 ELECTRICITY The usage associated with electricity use were calculated using the California Emissions Estimator Model (CalEEMod) Version 2022.1. The Southern California region’s electricity reliability has been of concern for the past several years due to the planned retirement of aging facilities that depend upon once-through cooling technologies, as well as the June 2013 retirement of the San Onofre Nuclear Generating Station (San Onofre). While the once-through cooling phase-out has been ongoing since the May 2010 adoption of the State Water Resources Control Board’s once- through cooling policy, the retirement of San Onofre complicated the situation. California ISO studies revealed the extent to which the South California Air Basin (SCAB) and the San Diego Air Basin (SDAB) region were vulnerable to low-voltage and post-transient voltage instability concerns. A preliminary plan to address these issues was detailed in the 2013 Integrative Energy Policy Report (IEPR) after a collaborative process with other energy agencies, utilities, and air districts (8). Similarly, the subsequent 2021 IEPR’s identify broad strategies that are aimed at maintaining electricity system reliability. Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 10 Electricity is currently provided to the Project by Southern California Edison (SCE). SCE provides electric power to more than 15 million persons in 15 counties and in 180 incorporated cities, within a service area encompassing approximately 50,000 square miles. Based on SCE’s 2018 Power Content Label Mix, SCE derives electricity from varied energy resources including: fossil fuels, hydroelectric generators, nuclear power plants, geothermal power plants, solar power generation, and wind farms. SCE also purchases from independent power producers and utilities, including out-of-state suppliers (9). California’s electricity industry is an organization of traditional utilities, private generating companies, and state agencies, each with a variety of roles and responsibilities to ensure that electrical power is provided to consumers. The California Independent Service Operator (ISO) is a nonprofit public benefit corporation and is the impartial operator of the State’s wholesale power grid and is charged with maintaining grid reliability, and to direct uninterrupted electrical energy supplies to California’s homes and communities. While utilities still own transmission assets, the ISO routes electrical power along these assets, maximizing the use of the transmission system and its power generation resources. The ISO matches buyers and sellers of electricity to ensure that enough power is available to meet demand. To these ends, every five minutes the ISO forecasts electrical demands, accounts for operating reserves, and assigns the lowest cost power plant unit to meet demands while ensuring adequate system transmission capacities and capabilities (10). Part of the ISO’s charge is to plan and coordinate grid enhancements to ensure that electrical power is provided to California consumers. To this end, utilities file annual transmission expansion/modification plans to accommodate the State’s growing electrical needs. The ISO reviews and either approves or denies the proposed additions. In addition, and perhaps most importantly, the ISO works with other areas in the western United States electrical grid to ensure that adequate power supplies are available to the State. In this manner, continuing reliable and affordable electrical power is assured to existing and new consumers throughout the State. Tables 2-2 identifies SCE’s specific proportional shares of electricity sources in 2021. As indicated in Table 2-2, the 2021 SCE Power Mix has renewable energy at 31.4% of the overall energy resources. Geothermal resources are at 5.7%, wind power is at 10.2%, large hydroelectric sources are at 2.3%, solar energy is at 14.9%, and coal is at 0% (11). Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 11 TABLE 2-2: SCE 2021 POWER CONTENT MIX Energy Resources 2021 SCE Power Mix Eligible Renewable 31.4% Biomass & Waste 0.1% Geothermal 5.7% Eligible Hydroelectric 0.5% Solar 14.9% Wind 10.2% Coal 0.0% Large Hydroelectric 2.3% Natural Gas 22.3% Nuclear 9.2% Other 0.2% Unspecified Sources of power* 34.6% Total 100% * "Unspecified sources of power" means electricity from transactions that are not traceable to specific generation sources 2.3 NATURAL GAS The following summary of natural gas customers and volumes, supplies, delivery of supplies, storage, service options, and operations is excerpted from information provided by the California Public Utilities Commission (CPUC). “The CPUC regulates natural gas utility service for approximately 10.8 million customers that receive natural gas from Pacific Gas and Electric (PG&E), Southern California Gas (SoCalGas), San Diego Gas & Electric (SDG&E), Southwest Gas, and several smaller natural gas utilities. The CPUC also regulates independent storage operators: Lodi Gas Storage, Wild Goose Storage, Central Valley Storage and Gill Ranch Storage. California's natural gas utilities provide service to over 11 million gas meters. SoCalGas and PG&E provide service to about 5.9 million and 4.3 million customers, respectively, while SDG&E provides service to over 800, 000 customers. In 2018, California gas utilities forecasted that they would deliver about 4740 million cubic feet per day (MMcfd) of gas to their customers, on average, under normal weather conditions. The overwhelming majority of natural gas utility customers in California are residential and small commercials customers, referred to as "core" customers. Larger volume gas customers, like electric generators and industrial customers, are called "noncore" customers. Although very small in number relative to core customers, noncore customers consume about 65% of the natural gas delivered by the state's natural gas utilities, while core customers consume about 35%. Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 12 A significant amount of gas (about 19%, or 1131 MMcfd, of the total forecasted California consumption in 2018) is also directly delivered to some California large volume consumers, without being transported over the regulated utility pipeline system. Those customers, referred to as "bypass" customers, take service directly from interstate pipelines or directly from California producers. SDG&E and Southwest Gas' southern division are wholesale customers of SoCalGas, i.e., they receive deliveries of gas from SoCalGas and in turn deliver that gas to their own customers. (Southwest Gas also provides natural gas distribution service in the Lake Tahoe area.) Similarly, West Coast Gas, a small gas utility, is a wholesale customer of PG&E. Some other wholesale customers are municipalities like the cities of Palo Alto, Long Beach, and Vernon, which are not regulated by the CPUC. Natural gas from out-of-state production basins is delivered into California via the interstate natural gas pipeline system. The major interstate pipelines that deliver out-of- state natural gas to California gas utilities are Gas Transmission Northwest Pipeline, Kern River Pipeline, Transwestern Pipeline, El Paso Pipeline, Ruby Pipeline, Mojave Pipeline, and Tuscarora. Another pipeline, the North Baja - Baja Norte Pipeline takes gas off the El Paso Pipeline at the California/Arizona border and delivers that gas through California into Mexico. While the Federal Energy Regulatory Commission (FERC) regulates the transportation of natural gas on the interstate pipelines, and authorizes rates for that service, the California Public Utilities Commission may participate in FERC regulatory proceedings to represent the interests of California natural gas consumers. The gas transported to California gas utilities via the interstate pipelines, as well as some of the California-produced gas, is delivered into the PG&E and SoCalGas intrastate natural gas transmission pipelines systems (commonly referred to as California's "backbone" pipeline system). Natural gas on the utilities' backbone pipeline systems is then delivered to the local transmission and distribution pipeline systems, or to natural gas storage fields. Some large volume noncore customers take natural gas delivery directly off the high-pressure backbone and local transmission pipeline systems, while core customers and other noncore customers take delivery off the utilities' distribution pipeline systems. The state's natural gas utilities operate over 100,000 miles of transmission and distribution pipelines, and thousands more miles of service lines. Bypass customers take most of their deliveries directly off the Kern/Mojave pipeline system, but they also take a significant amount of gas from California production. PG&E and SoCalGas own and operate several natural gas storage fields that are located within their service territories in northern and southern California, respectively. These storage fields, and four independently owned storage utilities - Lodi Gas Storage, Wild Goose Storage, Central Valley Storage, and Gill Ranch Storage - help meet peak seasonal and daily natural gas demand and allow California natural gas customers to secure natural gas supplies more efficiently. PG&E is a 25% owner of the Gill Ranch Storage field. These storage fields provide a significant amount of infrastructure capacity to help meet Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 13 California's natural gas requirements, and without these storage fields, California would need much more pipeline capacity in order to meet peak gas requirements. Prior to the late 1980s, California regulated utilities provided virtually all natural gas services to all their customers. Since then, the Commission has gradually restructured the California gas industry in order to give customers more options while assuring regulatory protections for those customers that wish to, or are required to, continue receiving utility- provided services. The option to purchase natural gas from independent suppliers is one of the results of this restructuring process. Although the regulated utilities procure natural gas supplies for most core customers, core customers have the option to purchase natural gas from independent natural gas marketers, called "core transport agents" (CTA). Contact information for core transport agents can be found on the utilities' web sites. Noncore customers, on the other hand, make natural gas supply arrangements directly with producers or with marketers. Another option resulting from the restructuring process occurred in 1993, when the Commission removed the utilities' storage service responsibility for noncore customers, along with the cost of this service from noncore customers' transportation rates. The Commission also encouraged the development of independent storage fields, and in subsequent years, all the independent storage fields in California were established. Noncore customers and marketers may now take storage service from the utility or from an independent storage provider (if available), and pay for that service, or may opt to take no storage service at all. For core customers, the Commission assures that the utility has adequate storage capacity set aside to meet core requirements, and core customers pay for that service. In a 1997 decision, the Commission adopted PG&E's "Gas Accord", which unbundled PG&E's backbone transmission costs from noncore transportation rates. This decision gave customers and marketers the opportunity to obtain pipeline capacity rights on PG&E's backbone transmission pipeline system, if desired, and pay for that service at rates authorized by the Commission. The Gas Accord also required PG&E to set aside a certain amount of backbone transmission capacity in order to deliver gas to its core customers. Subsequent Commission decisions modified and extended the initial terms of the Gas Accord. The "Gas Accord" framework is still in place today for PG&E's backbone and storage rates and services and is now simply referred to as PG&E Gas Transmission and Storage (GT&S). In a 2006 decision, the Commission adopted a similar gas transmission framework for Southern California, called the "firm access rights" system. SoCalGas and SDG&E implemented the firm access rights (FAR) system in 2008, and it is now referred to as the backbone transmission system (BTS) framework. As under the PG&E backbone transmission system, SoCalGas backbone transmission costs are unbundled from noncore transportation rates. Noncore customers and marketers may obtain, and pay for, firm backbone transmission capacity at various receipt points on the SoCalGas system. A Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 14 certain amount of backbone transmission capacity is obtained for core customers to assure meeting their requirements. Many if not most noncore customers now use a marketer to provide for several of the services formerly provided by the utility. That is, a noncore customer may simply arrange for a marketer to procure its supplies, and obtain any needed storage and backbone transmission capacity, in order to assure that it will receive its needed deliveries of natural gas supplies. Core customers still mainly rely on the utilities for procurement service, but they have the option to take procurement service from a CTA. Backbone transmission and storage capacity is either set aside or obtained for core customers in amounts to assure very high levels of service. In order properly operate their natural gas transmission pipeline and storage systems, PG&E and SoCalGas must balance the amount of gas received into the pipeline system and delivered to customers or to storage fields. Some of these utilities’ storage capacity is dedicated to this service, and under most circumstances, customers do not need to precisely match their deliveries with their consumption. However, when too much or too little gas is expected to be delivered into the utilities’ systems, relative to the amount being consumed, the utilities require customers to more precisely match up their deliveries with their consumption. And, if customers do not meet certain delivery requirements, they could face financial penalties. The utilities do not profit from these financial penalties - the amounts are then returned to customers as a whole. If the utilities find that they are unable to deliver all the gas that is expected to be consumed, they may even call for a curtailment of some gas deliveries. These curtailments are typically required for just the largest, noncore customers. It has been many years since there has been a significant curtailment of core customers in California.” (12) As indicated in the preceding discussions, natural gas is available from a variety of in-state and out-of-state sources and is provided throughout the state in response to market supply and demand. Complementing available natural gas resources, biogas may soon be available via existing delivery systems, thereby increasing the availability and reliability of resources in total. The CPUC oversees utility purchases and transmission of natural gas to ensure reliable and affordable natural gas deliveries to existing and new consumers throughout the State. 2.4 TRANSPORTATION ENERGY RESOURCES The Project would generate additional vehicle trips with resulting consumption of energy resources, predominantly gasoline and diesel fuel. The Department of Motor Vehicles (DMV) identified 36.2 million registered vehicles in California (13), and those vehicles consume an estimated 17.2 billion gallons of fuel each year1. Gasoline (and other vehicle fuels) are commercially provided commodities and would be available to the Project patrons and employees via commercial outlets. 1 Fuel consumptions estimated utilizing information from EMFAC2021. Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 15 California’s on-road transportation system includes 396,616 lane miles, more than 26.6 million passenger vehicles and light trucks, and almost 9.0 million medium- and heavy-duty vehicles (13). While gasoline consumption has been declining since 2008 it is still by far the dominant fuel. California is the second-largest consumer of petroleum products, after Texas, and accounts for 10% of the nation's total consumption. The state is the largest U.S. consumer of motor gasoline and jet fuel, and 85% of the petroleum consumed in California is used in the transportation sector (14). California accounts for less than 1% of total U.S. natural gas reserves and production. As with crude oil, California's natural gas production has experienced a gradual decline since 1985. In 2019, about 37% of the natural gas delivered to consumers went to the state's industrial sector, and about 28% was delivered to the electric power sector. Natural gas fueled more than two- fifths of the state's utility-scale electricity generation in 2019. The residential sector, where two- thirds of California households use natural gas for home heating, accounted for 22% of natural gas deliveries. The commercial sector received 12% of the deliveries to end users and the transportation sector consumed the remaining 1% (14). Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 16 This page intentionally left blank Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 17 3 REGULATORY BACKGROUND Federal and state agencies regulate energy use and consumption through various means and programs. On the federal level, the United States Department of Transportation, the United States Department of Energy, and the United States Environmental Protection Agency (EPA) are three federal agencies with substantial influence over energy policies and programs. On the state level, the CPUC and the CEC are two agencies with authority over different aspects of energy. Relevant federal and state energy-related laws and plans are summarized below. 3.1 FEDERAL REGULATIONS 3.1.1 INTERMODAL SURFACE TRANSPORTATION EFFICIENCY ACT OF 1991 (ISTEA) The ISTEA promoted the development of inter-modal transportation systems to maximize mobility as well as address national and local interests in air quality and energy. ISTEA contained factors that Metropolitan Planning Organizations (MPOs) were to address in developing transportation plans and programs, including some energy-related factors. To meet the new ISTEA requirements, MPOs adopted explicit policies defining the social, economic, energy, and environmental values guiding transportation decisions. 3.1.2 THE TRANSPORTATION EQUITY ACT FOR THE 21ST CENTURY (TEA-21) The TEA-21 was signed into law in 1998 and builds upon the initiatives established in the ISTEA legislation, discussed above. TEA-21 authorizes highway, highway safety, transit, and other efficient surface transportation programs. TEA-21 continues the program structure established for highways and transit under ISTEA, such as flexibility in the use of funds, emphasis on measures to improve the environment, and focus on a strong planning process as the foundation of good transportation decisions. TEA-21 also provides for investment in research and its application to maximize the performance of the transportation system through, for example, deployment of Intelligent Transportation Systems, to help improve operations and management of transportation systems and vehicle safety. 3.2 CALIFORNIA REGULATIONS 3.2.1 INTEGRATED ENERGY POLICY REPORT (IEPR) Senate Bill 1389 (Bowen, Chapter 568, Statutes of 2002) requires the CEC to prepare a biennial integrated energy policy report that assesses major energy trends and issues facing the state’s electricity, natural gas, and transportation fuel sectors and provides policy recommendations to conserve resources; protect the environment; ensure reliable, secure, and diverse energy supplies; enhance the state’s economy; and protect public health and safety (Public Resources Code § 25301[a]). The CEC prepares these assessments and associated policy recommendations every two years, with updates in alternate years, as part of the Integrated Energy Policy Report. The 2021 IEPR was adopted February 22, 2022, and continues to work towards improving electricity, natural gas, and transportation fuel energy use in California. The 2021 IEPR provides Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 18 the results of the CEC’s assessments of a variety of energy issues facing California. Many of these issues will require action if the state is to meet its climate, energy, air quality, and other environmental goals while maintaining reliability and controlling costs. (15). 3.2.2 STATE OF CALIFORNIA ENERGY PLAN The CEC is responsible for preparing the State Energy Plan, which identifies emerging trends related to energy supply, demand, conservation, public health and safety, and the maintenance of a healthy economy. The Plan calls for the state to assist in the transformation of the transportation system to improve air quality, reduce congestion, and increase the efficient use of fuel supplies with the least environmental and energy costs. To further this policy, the plan identifies several strategies, including assistance to public agencies and fleet operators and encouragement of urban designs that reduce vehicle miles traveled (VMT) and accommodate pedestrian and bicycle access. 3.2.3 CALIFORNIA CODE TITLE 24, PART 6, ENERGY EFFICIENCY STANDARDS California Code of Regulations (CCR) Title 24 Part 6: The California Energy Code was first adopted in 1978 in response to a legislative mandate to reduce California’s energy consumption. The standards are updated periodically to allow consideration and possible incorporation of new energy efficient technologies and methods. CCR, Title 24, Part 11: California Green Building Standards Code (CALGreen) is a comprehensive and uniform regulatory code for all residential, commercial, and school buildings that went in effect on August 1, 2009, and is administered by the California Building Standards Commission. CALGreen is updated on a regular basis, with the most recent approved update consisting of the 2022 California Green Building Code Standards that will be effective on January 1, 2023. The CEC anticipates that the 2022 energy code will provide $1.5 billion in consumer benefits and reduce GHG emissions by 10 million metric tons (16). The Project would be required to comply with the applicable standards in place at the time building permit document submittals are made. These require, among other items (17): NONRESIDENTIAL MANDATORY MEASURES • Short-term bicycle parking. If the new project or an additional alteration is anticipated to generate visitor traffic, provide permanently anchored bicycle racks within 200 feet of the visitors’ entrance, readily visible to passers-by, for 5% of new visitor motorized vehicle parking spaces being added, with a minimum of one two-bike capacity rack (5.106.4.1.1). • Long-term bicycle parking. For new buildings with tenant spaces that have 10 or more tenant-occupants, provide secure bicycle parking for 5% of the tenant-occupant vehicular parking spaces with a minimum of one bicycle parking facility (5.106.4.1.2). • Designated parking for clean air vehicles. In new projects or additions to alterations that add 10 or more vehicular parking spaces, provide designated parking for any combination of low-emitting, fuel-efficient and carpool/van pool vehicles as shown in Table 5.106.5.2 (5.106.5.2). Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 19 • EV charging stations. New construction shall facilitate the future installation of EV supply equipment. The compliance requires empty raceways for future conduit and documentation that the electrical system has adequate capacity for the future load. The number of spaces to be provided for is contained in Table 5.106. 5.3.3 (5.106.5.3). Additionally, Table 5.106.5.4.1 specifies requirements for the installation of raceway conduit and panel power requirements for medium- and heavy-duty electric vehicle supply equipment for warehouses, grocery stores, and retail stores. • Outdoor light pollution reduction. Outdoor lighting systems shall be designed to meet the backlight, uplight and glare ratings per Table 5.106.8 (5.106.8). • Construction waste management. Recycle and/or salvage for reuse a minimum of 65% of the nonhazardous construction and demolition waste in accordance with Section 5.408.1.1. 5.405.1.2, or 5.408.1.3; or meet a local construction and demolition waste management ordinance, whichever is more stringent (5.408.1). • Excavated soil and land clearing debris. 100% of trees, stumps, rocks and associated vegetation and soils resulting primarily from land clearing shall be reuse or recycled. For a phased project, such material may be stockpiled on site until the storage site is developed (5.408.3). • Recycling by Occupants. Provide readily accessible areas that serve the entire building and are identified for the depositing, storage, and collection of non-hazardous materials for recycling, including (at a minimum) paper, corrugated cardboard, glass, plastics, organic waste, and metals or meet a lawfully enacted local recycling ordinance, if more restrictive (5.410.1). • Water conserving plumbing fixtures and fittings. Plumbing fixtures (water closets and urinals) and fittings (faucets and showerheads) shall comply with the following: o Water Closets. The effective flush volume of all water closets shall not exceed 1.28 gallons per flush (5.303.3.1) o Urinals. The effective flush volume of wall-mounted urinals shall not exceed 0.125 gallons per flush (5.303.3.2.1). The effective flush volume of floor- mounted or other urinals shall not exceed 0.5 gallons per flush (5.303.3.2.2). o Showerheads. Single showerheads shall have a minimum flow rate of not more than 1.8 gallons per minute and 80 psi (5.303.3.3.1). When a shower is served by more than one showerhead, the combine flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 1.8 gallons per minute at 80 psi (5.303.3.3.2). o Faucets and fountains. Nonresidential lavatory faucets shall have a maximum flow rate of not more than 0.5 gallons per minute at 60 psi (5.303.3.4.1). Kitchen faucets shall have a maximum flow rate of not more than 1.8 gallons per minute of 60 psi (5.303.3.4.2). Wash fountains shall have a maximum flow rate of not more than 1.8 gallons per minute (5.303.3.4.3). Metering faucets shall not deliver more than 0.20 gallons per cycle (5.303.3.4.4). Metering faucets for wash fountains shall have a maximum flow rate not more than 0.20 gallons per cycle (5.303.3.4.5). • Outdoor potable water uses in landscaped areas. Nonresidential developments shall comply with a local water efficient landscape ordinance or the current California Department of Water Resources’ Model Water Efficient Landscape Ordinance (MWELO), whichever is more stringent (5.304.1). Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 20 • Water meters. Separate submeters or metering devices shall be installed for new buildings or additions in excess of 50,000 sf or for excess consumption where any tenant within a new building or within an addition that is project to consume more than 1,000 gallons per day (GPD) (5.303.1.1 and 5.303.1.2). • Outdoor water uses in rehabilitated landscape projects equal or greater than 2,500 sf. Rehabilitated landscape projects with an aggregate landscape area equal to or greater than 2,500 sf requiring a building or landscape permit (5.304.3). • Commissioning. For new buildings 10,000 sf and over, building commissioning shall be included in the design and construction processes of the building project to verify that the building systems and components meet the owner’s or owner representative’s project requirements (5.410.2). 3.2.4 AB 1493 PAVLEY REGULATIONS AND FUEL EFFICIENCY STANDARDS California AB 1493, enacted on July 22, 2002, required CARB to develop and adopt regulations that reduce GHGs emitted by passenger vehicles and light duty trucks. Under this legislation, CARB adopted regulations to reduce GHG emissions from non-commercial passenger vehicles (cars and light-duty trucks). Although aimed at reducing GHG emissions, specifically, a co-benefit of the Pavley standards is an improvement in fuel efficiency and consequently a reduction in fuel consumption. 3.2.5 CALIFORNIA’S RENEWABLE PORTFOLIO STANDARD (RPS) First established in 2002 under Senate Bill (SB) 1078, California’s Renewable Portfolio Standards (RPS) requires retail sellers of electric services to increase procurement from eligible renewable resources to 33% of total retail sales by 2020 (18). 3.2.6 CLEAN ENERGY AND POLLUTION REDUCTION ACT OF 2015 (SB 350) In October 2015, the legislature approved, and the Governor signed SB 350, which reaffirms California’s commitment to reducing its GHG emissions and addressing climate change. Key provisions include an increase in the renewables portfolio standard (RPS), higher energy efficiency requirements for buildings, initial strategies towards a regional electricity grid, and improved infrastructure for electric vehicle charging stations. Specifically, SB 350 requires the following to reduce statewide GHG emissions: • Increase the amount of electricity procured from renewable energy sources from 33% to 50% by 2030, with interim targets of 40% by 2024, and 25% by 2027. • Double the energy efficiency in existing buildings by 2030. This target will be achieved through the California Public Utility Commission (CPUC), the California Energy Commission (CEC), and local publicly owned utilities. • Reorganize the Independent System Operator (ISO) to develop more regional electrify transmission markets and to improve accessibility in these markets, which will facilitate the growth of renewable energy markets in the western United States (California Leginfo 2015). Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 21 3.2.7 100 PERCENT CLEAN ENERGY ACT OF 2018 (SB 100) In September 2018, the legislature approved, and the Governor signed SB 100, which builds on the targets established in SB 1078 and SB 350. Most notably, SB 100 sets a goal of powering all retail electricity sold in California with renewable and zero-carbon resources. Additionally, SB 100 updates the interim renewables target from 50% to 60% by 2030. Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 22 This page intentionally left blank Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 23 4 PROJECT ENERGY DEMANDS AND ENERGY EFFICIENCY MEASURES 4.1 EVALUATION CRITERIA Per Appendix F of the State CEQA Guidelines (19), states that the means of achieving the goal of energy conservation includes the following: • Decreasing overall per capita energy consumption; • Decreasing reliance on fossil fuels such as coal, natural gas, and oil; and • Increasing reliance on renewable energy sources. In compliance with Appendix G of the State CEQA Guidelines (20), this report analyzes the project’s anticipated energy use during construction and operations to determine if the Project would: • Result in potentially significant environmental impact due to wasteful, inefficient, or unnecessary consumption of energy resources, during project construction or operation; or • Conflict with or obstruct a state or local plan for renewable energy or energy efficiency 4.2 METHODOLOGY Information from the CalEEMod Version 2021.1. outputs for the Oleander & Santa Ana Avenue Warehouse Air Quality Impact Analysis (AQIA) (21) was utilized in this analysis, detailing Project related construction equipment, transportation energy demands, and facility energy demands. 4.2.1 CALEEMOD In May 2022 California Air Pollution Control Officers Association (CAPCOA) in conjunction with other California air districts, including SCAQMD, released the latest version of the CalEEMod Version 2022.1. The purpose of this model is to calculate construction-source and operational- source criteria pollutants and GHG emissions from direct and indirect sources as well as energy usage (22). Accordingly, the latest version of CalEEMod has been used to determine the proposed Project’s anticipated transportation and facility energy demands. Outputs from the annual model runs are provided in Appendices 4.1. 4.2.2 EMISSION FACTORS MODEL On May 2, 2022, the EPA approved the 2021 version of the EMissions FACtor model (EMFAC) web database for use in State Implementation Plan and transportation conformity analyses. EMFAC2021 is a mathematical model that was developed to calculate emission rates, fuel consumption, VMT from motor vehicles that operate on highways, freeways, and local roads in California and is commonly used by the CARB to project changes in future emissions from on- road mobile sources (23). This energy study utilizes the different fuel types for each vehicle class from the annual EMFAC2021 emission inventory in order to derive the average vehicle fuel economy which is then used to determine the estimated annual fuel consumption associated with vehicle usage during Project construction and operational activities. For purposes of Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 24 analysis, the 2024 through 2025 analysis years were utilized to determine the average vehicle fuel economy used throughout the duration of the Project. Output from the EMFAC2021 model run is provided in Appendix 4.2. 4.3 CONSTRUCTION ENERGY DEMANDS The focus within this section is the energy implications of the construction process, specifically the power cost from on-site electricity consumption during construction of the proposed Project. 4.3.1 CONSTRUCTION POWER COST The total Project construction power costs is the summation of the products of the area (sf) by the construction duration and the typical power cost. CONSTRUCTION DURATION Construction is anticipated to begin in January 2024 and will last through June 2025 (21). The construction schedule utilized in the analysis, shown in Table 4-1, represents a “worst-case” analysis scenario. The duration of construction activity and associated equipment represents a reasonable approximation of the expected construction fleet as required per CEQA Guidelines (24). TABLE 4-1: CONSTRUCTION DURATION Construction Activity Start Date End Date Days Demolition 1/1/2024 1/29/2024 20 Site Preparation 1/30/2024 3/11/2024 30 Grading 3/12/2024 4/22/2024 30 Building Construction 4/23/2024 6/16/2025 300 Paving 2/11/2025 6/16/2025 90 Architectural Coating 3/25/2025 6/16/2025 60 PROJECT CONSTRUCTION POWER COST The 2022 National Construction Estimator identifies a typical power cost per 1,000 sf of construction per month of $2.41, which was used to calculate the Project’s total construction power cost (25). As shown on Table 4-2, the total power cost of the on-site electricity usage during the construction of the Project is estimated to be approximately $37,060.48. Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 25 TABLE 4-2: CONSTRUCTION POWER COST Land Use Power Cost (per 1,000 SF) Size (1,000 SF) Construction Duration (months) Project Construction Power Cost Unrefrigerated Warehouse-No Rail $2.41 540.849 17 $22,158.58 Parking Lot $2.41 155.074 17 $6,353.38 Other Asphalt Surfaces $2.41 208.653 17 $8,548.51 CONSTRUCTION POWER COST $37,060.48 4.3.2 CONSTRUCTION ELECTRICITY USAGE The total Project construction electricity usage is the summation of the products of the power cost (estimated in Table 4-2) by the utility provider cost per kilowatt hour (kWh) of electricity. PROJECT CONSTRUCTION ELECTRICITY USAGE The SCE’s general service rate schedule was used to determine the Project’s electrical usage. As of January 1, 2022, SCE’s general service rate is $0.13 per kilowatt hours (kWh) of electricity for industrial services (26). As shown on Table 4-3, the total electricity usage from on-site Project construction related activities is estimated to be approximately 281,358 kWh. TABLE 4-3: CONSTRUCTION ELECTRICITY USAGE Land Use Cost per kWh Project Construction Electricity Usage (kWh) Unrefrigerated Warehouse-No Rail $0.13 168,225 Parking Lot $0.13 48,234 Other Asphalt Surfaces $0.13 64,899 CONSTRUCTION ELECTRICITY USAGE 281,358 4.3.3 CONSTRUCTION EQUIPMENT FUEL ESTIMATES Fuel consumed by construction equipment would be the primary energy resource expended over the course of Project construction. CONSTRUCTION EQUIPMENT Consistent with industry standards and typical construction practices, each piece of equipment listed in Table 4-4 will operate up to a total of eight (8) hours per day, or more than two-thirds of the period during which construction activities are allowed pursuant to the code. It should be noted that most pieces of equipment would likely operate for fewer hours per day. A summary of construction equipment assumptions by phase is provided at Table 4-4. Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 26 TABLE 4-4: CONSTRUCTION EQUIPMENT ASSUMPTIONS Construction Activity Equipment Amount Hours Per Day Demolition Concrete/Industrial Saws 1 8 Excavators 3 8 Rubber Tired Dozers 2 8 Site Preparation Rubber Tired Dozers 3 8 Crawler Tractors 4 8 Grading Excavators 2 8 Graders 1 8 Rubber Tired Dozers 1 8 Scrapers 2 8 Crawler Tractors 2 8 Building Construction Cranes 1 8 Forklifts 6 8 Generator Sets 2 8 Tractors/Loaders/Backhoes 6 8 Welders 2 8 Paving Pavers 2 8 Paving Equipment 2 8 Rollers 2 8 Architectural Coating Air Compressors 1 8 PROJECT CONSTRUCTION EQUIPMENT FUEL CONSUMPTION Project construction activity timeline estimates, construction equipment schedules, equipment power ratings, load factors, and associated fuel consumption estimates are presented in Table 4- 5. The aggregate fuel consumption rate for all equipment is estimated at 18.5 horsepower hour per gallon (hp-hr-gal.), obtained from CARB 2018 Emissions Factors Tables and cited fuel consumption rate factors presented in Table D-24 of the Moyer guidelines (27). For the purposes of this analysis, the calculations are based on all construction equipment being diesel-powered which is consistent with industry standards. Diesel fuel would be supplied by existing commercial fuel providers serving the Project area and region2. As presented in Table 4-5, Project construction activities would consume an estimated 85,533 gallons of diesel fuel. Project construction would represent a “single-event” diesel fuel demand and would not require on- going or permanent commitment of diesel fuel resources for this purpose. 2 Based on Appendix A of the CalEEMod User’s Guide, Construction consists of several types of off-road equipment. Since the majority of the off-road construction equipment used for construction projects are diesel fueled, CalEEMod assumes all of the equipment operates on diesel fuel. Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 27 TABLE 4-5: CONSTRUCTION EQUIPMENT FUEL CONSUMPTION ESTIMATES Construction Activity Duration (Days) Equipment HP Rating Quantity Usage Hours Load Factor HP- hrs/day Total Fuel Consumption Demolition 20 Concrete/Industrial Saws 33 1 8 0.73 193 208 Excavators 36 3 8 0.38 328 355 Rubber Tired Dozers 367 2 8 0.4 2,349 2,539 Site Preparation 30 Rubber Tired Dozers 367 3 8 0.4 3,523 5,713 Crawler Tractors 87 4 8 0.43 1,197 1,941 Grading 30 Excavators 36 2 8 0.38 219 355 Graders 148 1 8 0.41 485 787 Rubber Tired Dozers 367 1 8 0.4 1,174 1,904 Scrapers 423 2 8 0.48 3,249 5,268 Crawler Tractors 87 2 8 0.43 599 971 Building Construction 300 Cranes 367 1 8 0.29 851 13,807 Forklifts 82 6 8 0.2 787 12,765 Generator Sets 14 2 8 0.74 166 2,688 Tractors/Loaders/Backhoes 84 6 8 0.37 1,492 24,192 Welders 46 2 8 0.45 331 5,371 Paving 90 Pavers 81 2 8 0.42 544 2,648 Paving Equipment 89 2 8 0.36 513 2,494 Rollers 36 2 8 0.38 219 1,065 Architectural Coating 60 Air Compressors 37 1 8 0.48 142 461 CONSTRUCTION FUEL DEMAND (GALLONS DIESEL FUEL) 85,533 Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 28 4.3.3 CONSTRUCTION TRIPS AND VMT Construction generates on-road vehicle emissions from vehicle usage for workers, hauling, and vendors commuting to and from the site. The number of workers, hauling, and vendor trips are presented below in Table 4-6. It should be noted that for Vendor Trips, specifically, CalEEMod only assigns Vendor Trips to the Building Construction phase. Vendor trips would likely occur during all phases of construction. As such, the CalEEMod defaults for Vendor Trips have been adjusted based on a ratio of the total vendor trips to the number of days of each subphase of activity. TABLE 4-6: CONSTRUCTION TRIPS AND VMT Construction Activity Worker Trips Per Day Vendor Trips Per Day Hauling Trips Per Day Demolition 15 5 16 Site Preparation 18 7 0 Grading 20 7 0 Building Construction 227 70 0 Paving 15 0 0 Architectural Coating 45 0 0 4.3.4 CONSTRUCTION WORKER FUEL ESTIMATES With respect to estimated VMT for the Project, the construction worker trips would generate an estimated 1,346,373 VMT during the 17 months of construction (21). Based on CalEEMod methodology, it is assumed that 50% of all vendor trips are from light-duty-auto vehicles (LDA), 25% are from light-duty-trucks (LDT13), and 25% are from light-duty-trucks (LDT24). Data regarding Project related construction worker trips were based on CalEEMod defaults utilized within the AQIA. Vehicle fuel efficiencies for LDA, LDT1, and LDT2 were estimated using information generated within the 2021 version of the EMFAC developed by CARB. EMFAC2021 is a mathematical model that was developed to calculate emission rates, fuel consumption, and VMT from motor vehicles that operate on highways, freeways, and local roads in California and is commonly used by the CARB to project changes in future emissions from on-road mobile sources (23). EMFAC2021 was run for the LDA, LDT1, and LDT2 vehicle class within the California sub-area for the 2024 through 2025 calendar years. Data from EMFAC2021 is shown in Appendix 4.2. Table 4-7 provides an estimated annual fuel consumption resulting from Project construction worker trips. Based on Table 4-7, it is estimated that 49,106 gallons of fuel will be consumed related to construction worker trips during full construction of the Project. 3 Vehicles under the LDT1 category have a gross vehicle weight rating (GVWR) of less than 6,000 lbs. and equivalent test weight (ETW) of less than or equal to 3,750 lbs. 4 Vehicles under the LDT2 category have a GVWR of less than 6,000 lbs. and ETW between 3,751 lbs. and 5,750 lbs. Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 29 TABLE 4-7: CONSTRUCTION WORKER FUEL CONSUMPTION ESTIMATES Year Construction Activity Duration (Days) Worker Trips/Day Trip Length (miles) VMT Average Vehicle Fuel Economy (mpg) Estimated Fuel Consumption (gallons) 2024 LDA Demolition 21 8 18.5 3,108 31.57 98 Site Preparation 30 9 18.5 4,995 31.57 158 Grading 30 10 18.5 5,550 31.57 176 Building Construction 181 114 18.5 381,729 31.57 12,090 LDT1 Demolition 21 4 18.5 1,554 24.59 63 Site Preparation 30 5 18.5 2,775 24.59 113 Grading 30 5 18.5 2,775 24.59 113 Building Construction 181 57 18.5 190,865 24.59 7,761 LDT2 Demolition 21 4 18.5 1,554 24.51 63 Site Preparation 30 5 18.5 2,775 24.51 113 Grading 30 5 18.5 2,775 24.51 113 Building Construction 181 57 18.5 190,865 24.51 7,789 2025 LDA Building Construction 119 114 18.5 250,971 32.57 7,706 Paving 90 8 18.5 13,320 32.57 409 Architectural Coating 60 23 18.5 25,530 32.57 784 LDT1 Building Construction 119 57 18.5 125,486 25.11 4,997 Paving 90 4 18.5 6,660 25.11 265 Architectural Coating 60 12 18.5 13,320 25.11 530 LDT2 Building Construction 119 57 18.5 125,486 25.24 4,972 Paving 90 4 18.5 6,660 25.24 264 Architectural Coating 60 12 18.5 13,320 25.24 528 TOTAL CONSTRUCTION WORKER FUEL CONSUMPTION 49,106 It should be noted that construction worker trips would represent a “single-event” gasoline fuel demand and would not require on-going or permanent commitment of fuel resources for this purpose. Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 30 4.3.5 CONSTRUCTION VENDOR/HAULING FUEL ESTIMATES With respect to estimated VMT, the construction vendor trips (vehicles that deliver materials to the site during construction) would generate an estimated 227,101 VMT along area roadways for the Project over the duration of construction activity (21). It is assumed that 50% of all vendor trips are from medium-heavy duty trucks (MHDT), 50% of vendor trips are from heavy-heavy duty trucks (HHDT), and 100% of hauling trips are from HHDTs. These assumptions are consistent with the CalEEMod defaults utilized within the within the AQIA (21). Vehicle fuel efficiencies for MHDTs and HHDTs were estimated using information generated within EMFAC2021. EMFAC2021 was run for the MHDT and HHDT vehicle classes within the California sub-area for the 2024 through 2025 calendar years. Data from EMFAC2021 is shown in Appendix 4.2. Based on Table 4-8, it is estimated that 32,423 gallons of fuel will be consumed related to construction vendor trips during full construction of the Project. TABLE 4-8: CONSTRUCTION VENDOR FUEL CONSUMPTION ESTIMATES (1 OF 3) Year Construction Activity Duration (Days) Vendor/ Hauling Trips/Day Trip Length (miles) VMT Average Vehicle Fuel Economy (mpg) Estimated Fuel Consumption (gallons) 2024 MHDT Demolition 21 3 10.2 643 8.34 77 Site Preparation 30 4 10.2 1,224 8.34 147 Grading 30 4 10.2 1,224 8.34 147 Building Construction 181 35 10.2 64,617 8.34 7,747 HHDT (Vendor) Demolition 21 3 10.2 643 6.03 107 Site Preparation 30 4 10.2 1,224 6.03 203 Grading 30 4 10.2 1,224 6.03 203 Building Construction 181 35 10.2 64,617 6.03 10,724 HHDT (Hauling) Demolition 21 16 20 6,720 6.03 1,115 2025 MHDT Building Construction 119 35 10.2 42,483 8.46 5,023 HHDT (Vendor) Building Construction 119 35 10.2 42,483 6.13 6,930 TOTAL CONSTRUCTION VENDOR/HAULING FUEL CONSUMPTION 32,423 Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 31 It should be noted that Project construction vendor trips would represent a “single-event” diesel fuel demand and would not require on-going or permanent commitment of diesel fuel resources for this purpose. 4.3.6 CONSTRUCTION ENERGY EFFICIENCY/CONSERVATION MEASURES Starting in 2014, CARB adopted the nation's first regulation aimed at cleaning up off-road construction equipment such as bulldozers, graders, and backhoes. These requirements ensure fleets gradually turnover the oldest and dirtiest equipment to newer, cleaner models and prevent fleets from adding older, dirtier equipment. As such, the equipment used for Project construction would conform to CARB regulations and California emissions standards. It should also be noted that there are no unusual Project characteristics or construction processes that would require the use of equipment that would be more energy intensive than is used for comparable activities; or equipment that would not conform to current emissions standards (and related fuel efficiencies). Equipment employed in construction of the Project would therefore not result in inefficient wasteful, or unnecessary consumption of fuel. Construction contractors would be required to comply with applicable CARB regulation regarding retrofitting, repowering, or replacement of diesel off-road construction equipment. Additionally, CARB has adopted the Airborne Toxic Control Measure to limit heavy-duty diesel motor vehicle idling in order to reduce public exposure to diesel particulate matter and other Toxic Air Contaminants. Compliance with anti-idling and emissions regulations would result in a more efficient use of construction-related energy and the minimization or elimination of wasteful or unnecessary consumption of energy. Idling restrictions and the use of newer engines and equipment would result in less fuel combustion and energy consumption. Additional construction-source energy efficiencies would occur due to required California regulations and best available control measures (BACM). For example, CCR Title 13, Motor Vehicles, section 2449(d)(3) Idling, limits idling times of construction vehicles to no more than five minutes, thereby precluding unnecessary and wasteful consumption of fuel due to unproductive idling of construction equipment. Section 2449(d)(3) requires that grading plans shall reference the requirement that a sign shall be posted on-site stating that construction workers need to shut off engines at or before five minutes of idling.” In this manner, construction equipment operators are required to be informed that engines are to be turned off at or prior to five minutes of idling. Enforcement of idling limitations is realized through periodic site inspections conducted by City building officials, and/or in response to citizen complaints. A full analysis related to the energy needed to form construction materials is not included in this analysis due to a lack of detailed Project-specific information on construction materials. At this time, an analysis of the energy needed to create Project-related construction materials would be extremely speculative and thus has not been prepared. In general, the construction processes promote conservation and efficient use of energy by reducing raw materials demands, with related reduction in energy demands associated with raw materials extraction, transportation, processing, and refinement. Use of materials in bulk reduces energy demands associated with preparation and transport of construction materials as well as Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 32 the transport and disposal of construction waste and solid waste in general, with corollary reduced demands on area landfill capacities and energy consumed by waste transport and landfill operations. 4.4 OPERATIONAL ENERGY DEMANDS Energy consumption in support of or related to Project operations would include transportation energy demands (energy consumed by passenger car and truck vehicles accessing the Project site) and facilities energy demands (energy consumed by building operations and site maintenance activities). 4.4.1 TRANSPORTATION ENERGY DEMANDS Energy that would be consumed by Project-generated traffic is a function of total VMT and estimated vehicle fuel economies of vehicles accessing the Project site. The VMT per vehicle class can be determined by evaluated in the vehicle fleet mix and the total VMT. As with worker and vendors trips, operational vehicle fuel efficiencies were estimated using information generated within EMFAC2021 developed by CARB (23). EMFAC2021 was run for the San Bernardino County area for the 2025 calendar year. Data from EMFAC2021 is shown in Appendix 4.2. As summarized on Table 4-9 the Project will result in 3,593,663 annual VMT and an estimated annual fuel consumption of 396,865 gallons of fuel. TABLE 4-9: TOTAL PROJECT-GENERATED TRAFFIC ANNUAL FUEL CONSUMPTION Vehicle Type Annual VMT Average Vehicle Fuel Economy (mpg) Estimated Annual Fuel Consumption (gallons) LDA 508,864 32.57 15,625 LDT1 41,158 25.11 1,639 LDT2 207,411 25.24 8,218 MDV 156,311 20.54 7,610 MCY 21,414 42.15 508 LHDT1 356,884 16.22 22,008 LHDT2 97,007 15.27 6,354 MHDT 551,153 8.46 65,167 HHDT 1,653,460 6.13 269,737 TOTAL (ALL VEHICLES) 3,593,663 396,865 4.4.2 FACILITY ENERGY DEMANDS Project building operations activities would result in the consumption of electricity. Electricity would be supplied to the Project by SCE. Electricity demands of the Project are summarized in Table 4-10 and provided in Appendix 4.1. Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 33 TABLE 4-10: PROJECT ANNUAL OPERATIONAL NATURAL GAS DEMAND SUMMARY Land Use Electricity Demand (kWh/year) Unrefrigerated Warehouse-No Rail 2,498,021 Parking Lot 135,997 Other Asphalt Surfaces 0 TOTAL PROJECT ENERGY DEMAND 2,634,018 kBTU – kilo-British Thermal Units 4.4.3 OPERATIONAL ENERGY EFFICIENCY/CONSERVATION MEASURES Energy efficiency/energy conservation attributes of the Project would be complemented by increasingly stringent state and federal regulatory actions addressing vehicle fuel economies and vehicle emissions standards; and enhanced building/utilities energy efficiencies mandated under California building codes (e.g., Title24, California Green Building Standards Code). ENHANCED VEHICLE FUEL EFFICIENCIES Project annual fuel consumption estimates presented previously in Table 4-9 represent likely potential maximums that would occur for the Project. Under subsequent future conditions, average fuel economies of vehicles accessing the Project site can be expected to improve as older, less fuel-efficient vehicles are removed from circulation, and in response to fuel economy and emissions standards imposed on newer vehicles entering the circulation system. Enhanced fuel economies realized pursuant to federal and state regulatory actions, and related transition of vehicles to alternative energy sources (e.g., electricity, natural gas, biofuels, hydrogen cells) would likely decrease future gasoline fuel demands per VMT. Location of the Project proximate to regional and local roadway systems tends to reduce VMT within the region, acting to reduce regional vehicle energy demands. The Property Owner/Developer would comply with the City‘s transportation demand management ordinance (see Chapter 17.78 of the Development Code). 4.5 SUMMARY 4.5.1 CONSTRUCTION ENERGY DEMANDS The estimated power cost of on-site electricity usage during the construction of the Project is assumed to be approximately $37,060.48. Additionally, based on the assumed power cost, it is estimated that the total electricity usage during construction, after full Project build-out, is calculated to be approximately 281,358 kWh. Construction equipment used by the Project would result in single event consumption of approximately 85,533 gallons of diesel fuel. Construction equipment use of fuel would not be atypical for the type of construction proposed because there are no aspects of the Project’s proposed construction process that are unusual or energy-intensive, and Project construction Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 34 equipment would conform to the applicable CARB emissions standards, acting to promote equipment fuel efficiencies. CCR Title 13, Title 13, Motor Vehicles, section 2449(d)(3) Idling, limits idling times of construction vehicles to no more than 5 minutes, thereby precluding unnecessary and wasteful consumption of fuel due to unproductive idling of construction equipment. BACMs inform construction equipment operators of this requirement. Enforcement of idling limitations is realized through periodic site inspections conducted by City building officials, and/or in response to citizen complaints. Construction worker trips for full construction of the Project would result in the estimated fuel consumption of 49,106 gallons of fuel. Additionally, fuel consumption from construction vendor trips (MHDTs and HHDTs) will total approximately 32,423 gallons. Diesel fuel would be supplied by City and regional commercial vendors. Indirectly, construction energy efficiencies and energy conservation would be achieved using bulk purchases, transport and use of construction materials. The 2021 IEPR released by the CEC has shown that fuel efficiencies are getting better within on and off-road vehicle engines due to more stringent government requirements (28). As supported by the preceding discussions, Project construction energy consumption would not be considered inefficient, wasteful, or otherwise unnecessary. 4.5.2 OPERATIONAL ENERGY DEMANDS TRANSPORTATION ENERGY DEMANDS Annual vehicular trips and related VMT generated by the operation of the Project would result in a fuel demand of 396,865 gallons of fuel. Fuel would be provided by current and future commercial vendors. Trip generation and VMT generated by the Project are consistent with other industrial uses of similar scale and configuration, as reflected respectively in the Institute of Transportation Engineers (ITE) Trip Generation Manual ((11th Ed., 2021); and CalEEMod. As such, Project operations would not result in excessive and wasteful vehicle trips and VMT, nor excess and wasteful vehicle energy consumption compared to other industrial uses. It should be noted that the state strategy for the transportation sector for medium and heavy- duty trucks is focused on making trucks more efficient and expediting truck turnover rather than reducing VMT from trucks. This is in contrast to the passenger vehicle component of the transportation sector where both per-capita VMT reductions and an increase in vehicle efficiency are forecasted to be needed to achieve the overall state emissions reductions goals. Heavy duty trucks involved in goods movements are generally controlled on the technology side and through fleet turnover of older trucks and engines to newer and cleaner trucks and engines. The first battery-electric heavy-heavy duty trucks are being tested this year and SCAQMD is looking to integrate this new technology into large-scale truck operations. The following state strategies reduce GHG emissions from the medium and heavy-duty trucks: • CARB’s Mobile Source Strategy focuses on reducing GHGs through the transition to zero and low emission vehicles and from medium-duty and heavy-duty trucks. Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 35 • CARB’s Sustainable Freight Action Plan establishes a goal to improve freight efficiency by 25 percent by 2030, deploy over 100,000 freight vehicles and equipment capable of zero emission operation and maximize both zero and near-zero emission freight vehicles and equipment powered by renewable energy by 2030. • CARB’s Emissions Reduction Plan for Ports and Goods Movement (Goods Movement Plan) in California focuses on reducing heavy-duty truck-related emissions focus on establishment of emissions standards for trucks, fleet turnover, truck retrofits, and restriction on truck idling (CARB 2006). While the focus of Goods Movement Plan is to reduce criteria air pollutant and air toxic emissions, the strategies to reduce these pollutants would also generally have a beneficial effect in reducing GHG emissions. • CARB’s On-Road Truck and Bus Regulation (2010) requires diesel trucks and buses that operate in California to be upgraded to reduce emissions. Newer heavier trucks and buses must meet particulate matter filter requirements beginning January 1, 2012. Lighter and older heavier trucks must be replaced starting January 1, 2015. By January 1, 2023, nearly all trucks and buses will need to have 2010 model year engines or equivalent (29). • CARB’s Heavy-Duty (Tractor-Trailer) GHG Regulation requires SmartWay tractor trailers that include idle-reduction technologies, aerodynamic technologies, and low-rolling resistant tires that would reduce fuel consumption and associated GHG emissions. The proposed Project would implement project design features that would facilitate the accessibility, parking, and loading of trucks on site. Enhanced fuel economies realized pursuant to federal and state regulatory actions, and related transition of vehicles to alternative energy sources (e.g., electricity, natural gas, biofuels, hydrogen cells) would likely decrease future gasoline fuel demands per VMT. Location of the Project proximate to regional and local roadway systems tends to reduce VMT within the region, acting to reduce regional vehicle energy demands. The Project would implement sidewalks, facilitating and encouraging pedestrian access. Facilitating pedestrian and bicycle access would reduce VMT and associated energy consumption. In compliance with the California Green Building Standards Code and City requirements, the Project would promote the use of bicycles as an alternative mean of transportation by providing short-term and/or long-term bicycle parking accommodations. As supported by the preceding discussions, Project transportation energy consumption would not be considered inefficient, wasteful, or otherwise unnecessary. FACILITY ENERGY DEMANDS Project facility operational energy demands are estimated at: 2,634,018 kWh/year of electricity. Electricity would be supplied by SCE. The Project proposes conventional industrial uses reflecting contemporary energy efficient/energy conserving designs and operational programs. The Project does not propose uses that are inherently energy intensive and the energy demands in total would be comparable to other industrial uses of similar scale and configuration. Lastly, the Project will comply with the applicable Title 24 standards. Compliance itself with applicable Title 24 standards will ensure that the Project energy demands would not be inefficient, wasteful, or otherwise unnecessary. Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 36 This page intentionally left blank Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 37 5 CONCLUSIONS 5.1 ENERGY IMPACT 1 Result in potentially significant environmental impact due to wasteful, inefficient, or unnecessary consumption of energy resources, during project construction or operation. As supported by the preceding analyses, Project construction and operations would not result in the inefficient, wasteful, or unnecessary consumption of energy. The Project would therefore not cause or result in the need for additional energy producing or transmission facilities. The Project would not engage in wasteful or inefficient uses of energy and aims to achieve energy conservations goals within the State of California. 5.2 ENERGY IMPACT 2 Conflict with or obstruct a state or local plan for renewable energy or energy efficiency. The Project’s consistency with the applicable state and local plans is discussed below. CONSISTENCY WITH ISTEA Transportation and access to the Project site is provided by the local and regional roadway systems. The Project would not interfere with, nor otherwise obstruct intermodal transportation plans or projects that may be realized pursuant to the ISTEA because SCAG is not planning for intermodal facilities on or through the Project site. CONSISTENCY WITH TEA-21 The Project site is located along major transportation corridors with proximate access to the Interstate freeway system. The site selected for the Project facilitates access, acts to reduce vehicle miles traveled, takes advantage of existing infrastructure systems, and promotes land use compatibilities through collocation of similar uses. The Project supports the strong planning processes emphasized under TEA-21. The Project is therefore consistent with, and would not otherwise interfere with, nor obstruct implementation of TEA-21. CONSISTENCY WITH IEPR Electricity would be provided to the Project by SCE. SCE’s Clean Power and Electrification Pathway (CPEP) white paper builds on existing state programs and policies. As such, the Project is consistent with, and would not otherwise interfere with, nor obstruct implementation the goals presented in the 2021 IEPR. Additionally, the Project will comply with the applicable Title 24 standards which would ensure that the Project energy demands would not be inefficient, wasteful, or otherwise unnecessary. As such, development of the proposed Project would support the goals presented in the 2021 IEPR. Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 38 CONSISTENCY WITH STATE OF CALIFORNIA ENERGY PLAN The Project site is located along major transportation corridors with proximate access to the Interstate freeway system. The site selected for the Project facilitates access and takes advantage of existing infrastructure systems. The Project therefore supports urban design and planning processes identified under the State of California Energy Plan, is consistent with, and would not otherwise interfere with, nor obstruct implementation of the State of California Energy Plan. CONSISTENCY WITH CALIFORNIA CODE TITLE 24, PART 6, ENERGY EFFICIENCY STANDARDS The 2022 version of Title 24 was adopted by the CEC and will become effective on January 1, 2023. The Project would be required to comply with the applicable standards in place at the time building permit document submittals are made. Therefore, the Project would not result in a significant impact on energy resources (30). The proposed Project would be subject to Title 24 standards. CONSISTENCY WITH CALIFORNIA CODE TITLE 24, PART 11, CALGREEN As previously stated, CCR, Title 24, Part 11: CALGreen is a comprehensive and uniform regulatory code for all residential, commercial, and school buildings that went in effect on January 1, 2009, and is administered by the California Building Standards Commission. CALGreen is updated on a regular basis, with the most recent approved update consisting of the 2022 California Green Building Code Standards which will become effective January 1, 2023. The proposed Project would be required to comply with the applicable standards in place at the time building permit document submittals are made. CONSISTENCY WITH AB 1493 AB 1493 is not applicable to the Project as it is a statewide measure establishing vehicle emissions standards. No feature of the Project would interfere with implementation of the requirements under AB 1493. CONSISTENCY WITH RPS California’s RPS is not applicable to the Project as it is a statewide measure that establishes a renewable energy mix. No feature of the Project would interfere with implementation of the requirements under RPS. CONSISTENCY WITH SB 350 The proposed Project would use energy from SCE, which have committed to diversify their portfolio of energy sources by increasing energy from wind and solar sources. No feature of the Project would interfere with implementation of SB 350. Additionally, the Project would be designed and constructed to implement the energy efficiency measures for new industrial developments and would include several measures designed to reduce energy consumption. As shown above, the Project would not conflict with any of the state or local plans. As such, a less than significant impact is expected. Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 39 This page intentionally left blank Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 40 6 REFERENCES 1. Association of Environmental Professionals. 2020 CEQA California Environmental Quality Act. 2020. 2. Administration, U.S. Energy Information. California State Profile and Energy Estimates. [Online] https://www.eia.gov/state/data.php?sid=CA#ConsumptionExpenditures. 3. California Energy Commission. Transportation Energy Demand Forecast 2018-2030. 2018. 4. Alternate Fuels Data Center. U.S. Department of Energy. [Online] https://afdc.energy.gov/states/ca. 5. U.S. Energy Information Administration. California Energy Consumption by End-Use Sector 2019. California State Profile and Energy Estimates. [Online] https://www.eia.gov/state/?sid=CA#tabs-2. 6. California Energy Commission. 2020 Total System Electric Generation. CA.gov. [Online] https://www.energy.ca.gov/data-reports/energy-almanac/california-electricity-data/2020-total- system-electric-generation. 7. U.S. Energy Information Administration. California State Profile and Energy Estimates . [Online] https://www.eia.gov/state/?sid=CA. 8. California Energy Commission. 2013 Integrated Energy Policy Report. [Online] 2013. http://www.energy.ca.gov/2013publications/CEC-100-2013-001/CEC-100-2013-001-CMF.pdf. 9. —. California Energy Almanac. Utility Energy Supply Plans from 2013. [Online] https://www.energy.ca.gov/almanac/electricity_data/s-2_supply_forms_2013/. 10. California ISO. Understanding the ISO. [Online] http://www.caiso.com/about/Pages/OurBusiness/UnderstandingtheISO/default.aspx. 11. California Energy Commission. 2021 Power Content Label - Southern California Edison. [Online] https://www.sce.com/sites/default/files/custom- files/Web%20files/2021%20Power%20Content%20Label.pdf. 12. California Public Utilities Commission. Natural Gas and California. [Online] http://www.cpuc.ca.gov/general.aspx?id=4802. 13. Department of Motor Vehicles. State of California Department of Motor Vehicles Statistics For Publication January Through December 2021. 2021. 14. United States Energy Information Administration. California Analysis. Energy Information Administration. [Online] https://www.eia.gov/beta/states/states/ca/analysis. 15. California Energy Commission Staff. 2020 Integrated Energy Policy Report Update. [Online] 2020. https://www.energy.ca.gov/data-reports/reports/integrated-energy-policy-report/2020- integrated-energy-policy-report-update. 16. California Energy Commission. Energy Commission Adopts Updated Building Standards to Improve Efficiency, Reduce Emissions from Homes and Businesses. [Online] August 11, 2021. https://www.energy.ca.gov/news/2021-08/energy-commission-adopts-updated-building- standards-improve-efficiency-reduce-0. 17. California Department of General Services. 2022 CALGreen Code. CALGreen. [Online] https://codes.iccsafe.org/content/CAGBC2022P1. 18. California Energy Commission. Renewables Portfolio Standard (RPS). [Online] 2002. http://www.energy.ca.gov/portfolio/. 19. State of California. California Environmental Quality Act Guideline, California Public Resources Code, Title 14, Division 6, Chapter 3,. Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 41 20. Association of Environmental Professionals. 2019 CEQA California Environmental Quality Act. 2019. 21. Urban Crossroads, Inc. Oleander & Santa Ana Avenue Warehouse Air Quality Impact Analysis. 2022. 22. California Air Pollution Control Officers Association (CAPCOA). California Emissions Estimator Model (CalEEMod). [Online] May 2022. www.caleemod.com. 23. California Department of Transportation. EMFAC Software. [Online] http://www.dot.ca.gov/hq/env/air/pages/emfac.htm. 24. State of California. 2019 CEQA California Environmental Quality Act. 2019. 25. Pray, Richard. 2022 National Construction Estimator. Carlsbad : Craftsman Book Company, 2022. 26. Southern California Edison. Schedule GS-1 General Service. Regulatory Information - Rates Pricing. [Online] https://library.sce.com/content/dam/sce- doclib/public/regulatory/tariff/electric/schedules/general-service-&-industrial- rates/ELECTRIC_SCHEDULES_GS-1.pdf. 27. California Air Resources Board. Methods to Find the Cost-Effectiveness of Funding Air Quality Projects For Evaluating Motor Vehicle Registration Fee Projects And Congestion Mitigation and Air Quality Improvement (CMAQ) Projects, Emission Factor Tables. 2018. 28. California Energy Commission Staff. 2021 Integrated Energy Policy Report Update. [Online] 2021. https://www.energy.ca.gov/data-reports/reports/integrated-energy-policy-report/2021- integrated-energy-policy-report. 29. California Air Resources Board. Truck and Bus Regulation. [Online] https://ww2.arb.ca.gov/our- work/programs/truck-and-bus-regulation. 30. The California Energy Commission. 2022 Building Energy Efficiency Standards. California Energy Commission. [Online] 2022. https://www.energy.ca.gov/programs-and-topics/programs/building- energy-efficiency-standards/2022-building-energy-efficiency. Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 42 This page intentionally left blank Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report 43 7 CERTIFICATIONS The contents of this energy analysis report represent an accurate depiction of the environmental impacts associated with the proposed Oleander & Santa Ana Avenue Warehouse. The information contained in this energy analysis report is based on the best available data at the time of preparation. If you have any questions, please contact me directly at hqureshi@urbanxroads.com. Haseeb Qureshi Associate Principal Urban Crossroads, Inc. hqureshi@urbanxroads.com EDUCATION Master of Science in Environmental Studies California State University, Fullerton • May 2010 Bachelor of Arts in Environmental Analysis and Design University of California, Irvine • June 2006 PROFESSIONAL AFFILIATIONS AEP – Association of Environmental Planners AWMA – Air and Waste Management Association ASTM – American Society for Testing and Materials PROFESSIONAL CERTIFICATIONS Planned Communities and Urban Infill – Urban Land Institute • June 2011 Indoor Air Quality and Industrial Hygiene – EMSL Analytical • April 2008 Principles of Ambient Air Monitoring – California Air Resources Board • August 2007 AB2588 Regulatory Standards – Trinity Consultants • November 2006 Air Dispersion Modeling – Lakes Environmental • June 2006 Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report This page intentionally left blank Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report APPENDIX 4.1: CALEEMOD CONSTRUCTION EMISSIONS MODEL OUTPUTS 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 1 / 52 14581 Oleander and Santa Ana Detailed Report Table of Contents 1. Basic Project Information 1.1. Basic Project Information 1.2. Land Use Types 1.3. User-Selected Emission Reduction Measures by Emissions Sector 2. Emissions Summary 2.1. Construction Emissions Compared Against Thresholds 2.2. Construction Emissions by Year, Unmitigated 2.4. Operations Emissions Compared Against Thresholds 2.5. Operations Emissions by Sector, Unmitigated 3. Construction Emissions Details 3.1. Demolition (2024) - Unmitigated 3.3. Site Preparation (2024) - Unmitigated 3.5. Grading (2024) - Unmitigated 3.7. Building Construction (2024) - Unmitigated 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 2 / 52 3.9. Building Construction (2025) - Unmitigated 3.11. Paving (2025) - Unmitigated 3.13. Architectural Coating (2025) - Unmitigated 4. Operations Emissions Details 4.1. Mobile Emissions by Land Use 4.1.1. Unmitigated 4.2. Energy 4.2.1. Electricity Emissions By Land Use - Unmitigated 4.2.3. Natural Gas Emissions By Land Use - Unmitigated 4.3. Area Emissions by Source 4.3.2. Unmitigated 4.4. Water Emissions by Land Use 4.4.2. Unmitigated 4.5. Waste Emissions by Land Use 4.5.2. Unmitigated 4.6. Refrigerant Emissions by Land Use 4.6.1. Unmitigated 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 3 / 52 4.7. Offroad Emissions By Equipment Type 4.7.1. Unmitigated 4.8. Stationary Emissions By Equipment Type 4.8.1. Unmitigated 4.9. User Defined Emissions By Equipment Type 4.9.1. Unmitigated 4.10. Soil Carbon Accumulation By Vegetation Type 4.10.1. Soil Carbon Accumulation By Vegetation Type - Unmitigated 4.10.2. Above and Belowground Carbon Accumulation by Land Use Type - Unmitigated 4.10.3. Avoided and Sequestered Emissions by Species - Unmitigated 5. Activity Data 5.1. Construction Schedule 5.2. Off-Road Equipment 5.2.1. Unmitigated 5.3. Construction Vehicles 5.3.1. Unmitigated 5.4. Vehicles 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 4 / 52 5.4.1. Construction Vehicle Control Strategies 5.5. Architectural Coatings 5.6. Dust Mitigation 5.6.1. Construction Earthmoving Activities 5.6.2. Construction Earthmoving Control Strategies 5.7. Construction Paving 5.8. Construction Electricity Consumption and Emissions Factors 5.9. Operational Mobile Sources 5.9.1. Unmitigated 5.10. Operational Area Sources 5.10.1. Hearths 5.10.1.1. Unmitigated 5.10.2. Architectural Coatings 5.10.3. Landscape Equipment 5.11. Operational Energy Consumption 5.11.1. Unmitigated 5.12. Operational Water and Wastewater Consumption 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 5 / 52 5.12.1. Unmitigated 5.13. Operational Waste Generation 5.13.1. Unmitigated 5.14. Operational Refrigeration and Air Conditioning Equipment 5.14.1. Unmitigated 5.15. Operational Off-Road Equipment 5.15.1. Unmitigated 5.16. Stationary Sources 5.16.1. Emergency Generators and Fire Pumps 5.16.2. Process Boilers 5.17. User Defined 5.18. Vegetation 5.18.1. Land Use Change 5.18.1.1. Unmitigated 5.18.1. Biomass Cover Type 5.18.1.1. Unmitigated 5.18.2. Sequestration 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 6 / 52 5.18.2.1. Unmitigated 6. Climate Risk Detailed Report 6.1. Climate Risk Summary 6.2. Initial Climate Risk Scores 6.3. Adjusted Climate Risk Scores 6.4. Climate Risk Reduction Measures 7. Health and Equity Details 7.1. CalEnviroScreen 4.0 Scores 7.2. Healthy Places Index Scores 7.3. Overall Health & Equity Scores 7.4. Health & Equity Measures 7.5. Evaluation Scorecard 8. User Changes to Default Data 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 7 / 52 1. Basic Project Information 1.1. Basic Project Information Data Field Value Project Name 14581 Oleander and Santa Ana Lead Agency — Land Use Scale Project/site Analysis Level for Defaults County Windspeed (m/s)2.80 Precipitation (days)6.80 Location 34.05711223969459, -117.45159767923579 County San Bernardino-South Coast City Fontana Air District South Coast AQMD Air Basin South Coast TAZ 5310 EDFZ 10 Electric Utility Southern California Edison Gas Utility Southern California Gas 1.2. Land Use Types Land Use Subtype Size Unit Lot Acreage Building Area (sq ft)Landscape Area (sq ft) Special Landscape Area (sq ft) Population Description Unrefrigerated Warehouse-No Rail 541 1000sqft 12.4 540,849 159,626 ——— Parking Lot 396 Space 3.56 0.00 0.00 ——— 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 8 / 52 ———0.000.004.79Acre4.79Other Asphalt Surfaces User Defined Industrial 541 User Defined Unit 0.00 0.00 0.00 ——— 1.3. User-Selected Emission Reduction Measures by Emissions Sector No measures selected 2. Emissions Summary 2.1. Construction Emissions Compared Against Thresholds Criteria Pollutants (lb/day for daily, ton/yr for annual) and GHGs (lb/day for daily, MT/yr for annual) Un/Mit.TOG ROG NOx CO SO2 PM10E PM10D PM10T PM2.5E PM2.5D PM2.5T BCO2 NBCO2 CO2T CH4 N2O R CO2e Daily, Summer (Max) —————————————————— Unmit.5.29 49.0 37.9 60.4 0.07 1.78 4.36 5.56 1.64 1.06 2.69 —12,172 12,172 0.58 0.52 21.1 12,362 Daily, Winter (Max) —————————————————— Unmit.5.47 48.9 42.9 54.9 0.07 2.25 5.95 8.21 2.07 2.76 4.83 —11,836 11,836 0.58 0.52 0.55 12,005 Average Daily (Max) —————————————————— Unmit.3.05 8.62 20.1 27.8 0.04 0.86 2.57 3.43 0.79 0.75 1.54 —6,058 6,058 0.30 0.26 4.30 6,148 Annual (Max) —————————————————— Unmit.0.56 1.57 3.67 5.07 0.01 0.16 0.47 0.63 0.14 0.14 0.28 —1,003 1,003 0.05 0.04 0.71 1,018 2.2. Construction Emissions by Year, Unmitigated Criteria Pollutants (lb/day for daily, ton/yr for annual) and GHGs (lb/day for daily, MT/yr for annual) 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 9 / 52 Year TOG ROG NOx CO SO2 PM10E PM10D PM10T PM2.5E PM2.5D PM2.5T BCO2 NBCO2 CO2T CH4 N2O R CO2e Daily - Summer (Max) —————————————————— 2024 4.83 4.05 37.9 45.9 0.06 1.78 3.57 4.77 1.64 1.06 2.69 —9,735 9,735 0.48 0.47 19.2 9,908 2025 5.29 49.0 31.3 60.4 0.07 1.20 4.36 5.56 1.11 1.05 2.15 —12,172 12,172 0.58 0.52 21.1 12,362 Daily - Winter (Max) —————————————————— 2024 5.47 4.59 42.9 41.2 0.06 2.25 5.95 8.21 2.07 2.76 4.83 —9,464 9,464 0.49 0.47 0.50 9,618 2025 5.20 48.9 31.5 54.9 0.07 1.20 4.36 5.56 1.11 1.05 2.15 —11,836 11,836 0.58 0.52 0.55 12,005 Average Daily —————————————————— 2024 3.05 2.52 20.1 27.8 0.04 0.86 2.57 3.43 0.79 0.75 1.54 —6,058 6,058 0.30 0.26 4.30 6,148 2025 1.55 8.62 9.50 16.6 0.02 0.36 1.31 1.66 0.33 0.31 0.64 —3,622 3,622 0.18 0.16 2.79 3,678 Annual —————————————————— 2024 0.56 0.46 3.67 5.07 0.01 0.16 0.47 0.63 0.14 0.14 0.28 —1,003 1,003 0.05 0.04 0.71 1,018 2025 0.28 1.57 1.73 3.04 < 0.005 0.07 0.24 0.30 0.06 0.06 0.12 —600 600 0.03 0.03 0.46 609 2.4. Operations Emissions Compared Against Thresholds Criteria Pollutants (lb/day for daily, ton/yr for annual) and GHGs (lb/day for daily, MT/yr for annual) Un/Mit.TOG ROG NOx CO SO2 PM10E PM10D PM10T PM2.5E PM2.5D PM2.5T BCO2 NBCO2 CO2T CH4 N2O R CO2e Daily, Summer (Max) —————————————————— Unmit.9.31 19.6 31.1 54.7 0.28 0.47 5.45 5.92 0.46 1.23 1.68 514 34,520 35,034 54.7 4.97 92.8 37,975 Daily, Winter (Max) —————————————————— Unmit.4.99 15.6 32.4 29.3 0.28 0.44 5.45 5.89 0.42 1.23 1.64 514 34,226 34,739 54.7 4.98 2.41 37,593 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 10 / 52 Average Daily (Max) —————————————————— Unmit.6.50 17.5 24.1 37.8 0.21 0.34 3.99 4.33 0.33 0.90 1.23 514 26,028 26,542 54.0 3.81 29.3 29,058 Annual (Max) —————————————————— Unmit.1.19 3.20 4.40 6.91 0.04 0.06 0.73 0.79 0.06 0.16 0.22 85.0 4,309 4,394 8.94 0.63 4.86 4,811 2.5. Operations Emissions by Sector, Unmitigated Criteria Pollutants (lb/day for daily, ton/yr for annual) and GHGs (lb/day for daily, MT/yr for annual) Sector TOG ROG NOx CO SO2 PM10E PM10D PM10T PM2.5E PM2.5D PM2.5T BCO2 NBCO2 CO2T CH4 N2O R CO2e Daily, Summer (Max) —————————————————— Mobile 5.12 2.69 30.9 31.2 0.28 0.44 5.45 5.89 0.42 1.23 1.64 —31,081 31,081 2.38 4.35 92.8 32,530 Area 4.18 16.9 0.20 23.5 < 0.005 0.03 —0.03 0.04 —0.04 —96.7 96.7 < 0.005 < 0.005 —97.1 Energy 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 —0.00 —2,516 2,516 0.24 0.03 —2,530 Water ———————————240 826 1,066 24.7 0.59 —1,859 Waste ———————————274 0.00 274 27.4 0.00 —959 Total 9.31 19.6 31.1 54.7 0.28 0.47 5.45 5.92 0.46 1.23 1.68 514 34,520 35,034 54.7 4.97 92.8 37,975 Daily, Winter (Max) —————————————————— Mobile 4.99 2.55 32.4 29.3 0.28 0.44 5.45 5.89 0.42 1.23 1.64 —30,884 30,884 2.39 4.36 2.41 32,244 Area —13.0 ———————————————— Energy 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 —0.00 —2,516 2,516 0.24 0.03 —2,530 Water ———————————240 826 1,066 24.7 0.59 —1,859 Waste ———————————274 0.00 274 27.4 0.00 —959 Total 4.99 15.6 32.4 29.3 0.28 0.44 5.45 5.89 0.42 1.23 1.64 514 34,226 34,739 54.7 4.98 2.41 37,593 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 11 / 52 ——————————————————Average Daily Mobile 3.64 1.86 23.9 21.7 0.21 0.32 3.99 4.31 0.31 0.90 1.20 —22,619 22,619 1.75 3.19 29.3 23,643 Area 2.86 15.7 0.14 16.1 < 0.005 0.02 —0.02 0.03 —0.03 —66.3 66.3 < 0.005 < 0.005 —66.5 Energy 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 —0.00 —2,516 2,516 0.24 0.03 —2,530 Water ———————————240 826 1,066 24.7 0.59 —1,859 Waste ———————————274 0.00 274 27.4 0.00 —959 Total 6.50 17.5 24.1 37.8 0.21 0.34 3.99 4.33 0.33 0.90 1.23 514 26,028 26,542 54.0 3.81 29.3 29,058 Annual —————————————————— Mobile 0.66 0.34 4.37 3.97 0.04 0.06 0.73 0.79 0.06 0.16 0.22 —3,745 3,745 0.29 0.53 4.86 3,914 Area 0.52 2.86 0.02 2.94 < 0.005 < 0.005 —< 0.005 0.01 —0.01 —11.0 11.0 < 0.005 < 0.005 —11.0 Energy 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 —0.00 —417 417 0.04 < 0.005 —419 Water ———————————39.7 137 176 4.08 0.10 —308 Waste ———————————45.4 0.00 45.4 4.53 0.00 —159 Total 1.19 3.20 4.40 6.91 0.04 0.06 0.73 0.79 0.06 0.16 0.22 85.0 4,309 4,394 8.94 0.63 4.86 4,811 3. Construction Emissions Details 3.1. Demolition (2024) - Unmitigated Criteria Pollutants (lb/day for daily, ton/yr for annual) and GHGs (lb/day for daily, MT/yr for annual) Location TOG ROG NOx CO SO2 PM10E PM10D PM10T PM2.5E PM2.5D PM2.5T BCO2 NBCO2 CO2T CH4 N2O R CO2e Onsite —————————————————— Daily, Summer (Max) —————————————————— Daily, Winter (Max) —————————————————— 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 12 / 52 3,437—0.030.143,4253,425—0.98—0.981.06—1.060.0321.724.92.623.12Off-Road Equipment Demolitio n ——————0.88 0.88 —0.13 0.13 ——————— Onsite truck 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Average Daily —————————————————— Off-Road Equipment 0.17 0.14 1.36 1.19 < 0.005 0.06 —0.06 0.05 —0.05 —188 188 0.01 < 0.005 —188 Demolitio n ——————0.05 0.05 —0.01 0.01 ——————— Onsite truck 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Annual —————————————————— Off-Road Equipment 0.03 0.03 0.25 0.22 < 0.005 0.01 —0.01 0.01 —0.01 —31.1 31.1 < 0.005 < 0.005 —31.2 Demolitio n ——————0.01 0.01 —< 0.005 < 0.005 ——————— Onsite truck 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Offsite —————————————————— Daily, Summer (Max) —————————————————— Daily, Winter (Max) —————————————————— Worker 0.08 0.07 0.09 0.96 0.00 0.00 0.01 0.01 0.00 0.00 0.00 —198 198 0.01 0.01 0.02 200 Vendor 0.02 < 0.005 0.19 0.10 < 0.005 < 0.005 0.01 0.01 < 0.005 < 0.005 0.01 —157 157 0.01 0.02 0.01 164 Hauling 0.15 0.02 1.43 0.77 0.01 0.02 0.08 0.10 0.01 0.03 0.04 —1,113 1,113 0.12 0.18 0.06 1,169 Average Daily —————————————————— 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 13 / 52 Worker < 0.005 < 0.005 < 0.005 0.06 0.00 0.00 < 0.005 < 0.005 0.00 0.00 0.00 —11.0 11.0 < 0.005 < 0.005 0.02 11.2 Vendor < 0.005 < 0.005 0.01 0.01 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 —8.59 8.59 < 0.005 < 0.005 0.01 9.00 Hauling 0.01 < 0.005 0.08 0.04 < 0.005 < 0.005 < 0.005 0.01 < 0.005 < 0.005 < 0.005 —61.0 61.0 0.01 0.01 0.06 64.1 Annual —————————————————— Worker < 0.005 < 0.005 < 0.005 0.01 0.00 0.00 < 0.005 < 0.005 0.00 0.00 0.00 —1.82 1.82 < 0.005 < 0.005 < 0.005 1.85 Vendor < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 —1.42 1.42 < 0.005 < 0.005 < 0.005 1.49 Hauling < 0.005 < 0.005 0.01 0.01 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 —10.1 10.1 < 0.005 < 0.005 0.01 10.6 3.3. Site Preparation (2024) - Unmitigated Criteria Pollutants (lb/day for daily, ton/yr for annual) and GHGs (lb/day for daily, MT/yr for annual) Location TOG ROG NOx CO SO2 PM10E PM10D PM10T PM2.5E PM2.5D PM2.5T BCO2 NBCO2 CO2T CH4 N2O R CO2e Onsite —————————————————— Daily, Summer (Max) —————————————————— Daily, Winter (Max) —————————————————— Off-Road Equipment 5.35 4.49 42.5 35.3 0.05 2.25 —2.25 2.07 —2.07 —5,529 5,529 0.22 0.04 —5,548 Dust From Material Movement ——————5.66 5.66 —2.69 2.69 ——————— Onsite truck 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Average Daily —————————————————— Off-Road Equipment 0.44 0.37 3.49 2.90 < 0.005 0.19 —0.19 0.17 —0.17 —454 454 0.02 < 0.005 —456 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 14 / 52 ———————0.220.22—0.470.47——————Dust From Material Movement Onsite truck 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Annual —————————————————— Off-Road Equipment 0.08 0.07 0.64 0.53 < 0.005 0.03 —0.03 0.03 —0.03 —75.2 75.2 < 0.005 < 0.005 —75.5 Dust From Material Movement ——————0.08 0.08 —0.04 0.04 ——————— Onsite truck 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Offsite —————————————————— Daily, Summer (Max) —————————————————— Daily, Winter (Max) —————————————————— Worker 0.10 0.09 0.10 1.12 0.00 0.00 0.01 0.01 0.00 0.00 0.00 —231 231 0.01 0.01 0.03 234 Vendor 0.02 0.01 0.26 0.14 < 0.005 < 0.005 0.01 0.02 < 0.005 < 0.005 0.01 —220 220 0.02 0.03 0.02 230 Hauling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Average Daily —————————————————— Worker 0.01 0.01 0.01 0.10 0.00 0.00 < 0.005 < 0.005 0.00 0.00 0.00 —19.2 19.2 < 0.005 < 0.005 0.04 19.5 Vendor < 0.005 < 0.005 0.02 0.01 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 —18.0 18.0 < 0.005 < 0.005 0.02 18.9 Hauling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Annual —————————————————— Worker < 0.005 < 0.005 < 0.005 0.02 0.00 0.00 < 0.005 < 0.005 0.00 0.00 0.00 —3.19 3.19 < 0.005 < 0.005 0.01 3.23 Vendor < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 —2.99 2.99 < 0.005 < 0.005 < 0.005 3.13 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 15 / 52 Hauling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 3.5. Grading (2024) - Unmitigated Criteria Pollutants (lb/day for daily, ton/yr for annual) and GHGs (lb/day for daily, MT/yr for annual) Location TOG ROG NOx CO SO2 PM10E PM10D PM10T PM2.5E PM2.5D PM2.5T BCO2 NBCO2 CO2T CH4 N2O R CO2e Onsite —————————————————— Daily, Summer (Max) —————————————————— Off-Road Equipment 4.69 3.94 37.6 31.4 0.06 1.77 —1.77 1.63 —1.63 —6,715 6,715 0.27 0.05 —6,738 Dust From Material Movement ——————2.67 2.67 —0.98 0.98 ——————— Onsite truck 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Daily, Winter (Max) —————————————————— Off-Road Equipment 4.69 3.94 37.6 31.4 0.06 1.77 —1.77 1.63 —1.63 —6,715 6,715 0.27 0.05 —6,738 Dust From Material Movement ——————2.67 2.67 —0.98 0.98 ——————— Onsite truck 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Average Daily —————————————————— Off-Road Equipment 0.39 0.32 3.09 2.58 0.01 0.15 —0.15 0.13 —0.13 —552 552 0.02 < 0.005 —554 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 16 / 52 ———————0.080.08—0.220.22——————Dust From Material Movement Onsite truck 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Annual —————————————————— Off-Road Equipment 0.07 0.06 0.56 0.47 < 0.005 0.03 —0.03 0.02 —0.02 —91.4 91.4 < 0.005 < 0.005 —91.7 Dust From Material Movement ——————0.04 0.04 —0.01 0.01 ——————— Onsite truck 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Offsite —————————————————— Daily, Summer (Max) —————————————————— Worker 0.11 0.10 0.10 1.69 0.00 0.00 0.02 0.02 0.00 0.00 0.00 —288 288 0.01 0.01 1.15 292 Vendor 0.02 0.01 0.25 0.13 < 0.005 < 0.005 0.01 0.02 < 0.005 < 0.005 0.01 —219 219 0.02 0.03 0.61 230 Hauling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Daily, Winter (Max) —————————————————— Worker 0.11 0.10 0.11 1.28 0.00 0.00 0.02 0.02 0.00 0.00 0.00 —264 264 0.01 0.01 0.03 267 Vendor 0.02 0.01 0.26 0.14 < 0.005 < 0.005 0.01 0.02 < 0.005 < 0.005 0.01 —220 220 0.02 0.03 0.02 230 Hauling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Average Daily —————————————————— Worker 0.01 0.01 0.01 0.11 0.00 0.00 < 0.005 < 0.005 0.00 0.00 0.00 —22.0 22.0 < 0.005 < 0.005 0.04 22.3 Vendor < 0.005 < 0.005 0.02 0.01 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 —18.0 18.0 < 0.005 < 0.005 0.02 18.9 Hauling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 17 / 52 Annual —————————————————— Worker < 0.005 < 0.005 < 0.005 0.02 0.00 0.00 < 0.005 < 0.005 0.00 0.00 0.00 —3.64 3.64 < 0.005 < 0.005 0.01 3.69 Vendor < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 —2.99 2.99 < 0.005 < 0.005 < 0.005 3.13 Hauling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 3.7. Building Construction (2024) - Unmitigated Criteria Pollutants (lb/day for daily, ton/yr for annual) and GHGs (lb/day for daily, MT/yr for annual) Location TOG ROG NOx CO SO2 PM10E PM10D PM10T PM2.5E PM2.5D PM2.5T BCO2 NBCO2 CO2T CH4 N2O R CO2e Onsite —————————————————— Daily, Summer (Max) —————————————————— Off-Road Equipment 2.63 2.20 20.3 25.3 0.04 0.91 —0.91 0.84 —0.84 —4,270 4,270 0.17 0.03 —4,285 Onsite truck 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Daily, Winter (Max) —————————————————— Off-Road Equipment 2.63 2.20 20.3 25.3 0.04 0.91 —0.91 0.84 —0.84 —4,270 4,270 0.17 0.03 —4,285 Onsite truck 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Average Daily —————————————————— Off-Road Equipment 1.30 1.09 10.1 12.5 0.02 0.45 —0.45 0.42 —0.42 —2,114 2,114 0.09 0.02 —2,122 Onsite truck 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Annual —————————————————— Off-Road Equipment 0.24 0.20 1.84 2.29 < 0.005 0.08 —0.08 0.08 —0.08 —350 350 0.01 < 0.005 —351 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 18 / 52 Onsite truck 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Offsite —————————————————— Daily, Summer (Max) —————————————————— Worker 1.30 1.19 1.10 19.2 0.00 0.00 0.19 0.19 0.00 0.00 0.00 —3,270 3,270 0.14 0.11 13.1 3,320 Vendor 0.23 0.06 2.52 1.35 0.02 0.03 0.13 0.16 0.03 0.05 0.08 —2,195 2,195 0.17 0.33 6.12 2,303 Hauling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Daily, Winter (Max) —————————————————— Worker 1.24 1.12 1.30 14.5 0.00 0.00 0.19 0.19 0.00 0.00 0.00 —2,997 2,997 0.14 0.11 0.34 3,035 Vendor 0.23 0.06 2.62 1.37 0.02 0.03 0.13 0.16 0.03 0.05 0.08 —2,196 2,196 0.17 0.33 0.16 2,298 Hauling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Average Daily —————————————————— Worker 0.61 0.55 0.64 7.55 0.00 0.00 0.09 0.09 0.00 0.00 0.00 —1,505 1,505 0.07 0.06 2.79 1,526 Vendor 0.11 0.03 1.31 0.67 0.01 0.02 0.06 0.08 0.02 0.02 0.04 —1,087 1,087 0.08 0.16 1.30 1,138 Hauling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Annual —————————————————— Worker 0.11 0.10 0.12 1.38 0.00 0.00 0.02 0.02 0.00 0.00 0.00 —249 249 0.01 0.01 0.46 253 Vendor 0.02 0.01 0.24 0.12 < 0.005 < 0.005 0.01 0.01 < 0.005 < 0.005 0.01 —180 180 0.01 0.03 0.22 188 Hauling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 3.9. Building Construction (2025) - Unmitigated Criteria Pollutants (lb/day for daily, ton/yr for annual) and GHGs (lb/day for daily, MT/yr for annual) Location TOG ROG NOx CO SO2 PM10E PM10D PM10T PM2.5E PM2.5D PM2.5T BCO2 NBCO2 CO2T CH4 N2O R CO2e Onsite —————————————————— 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 19 / 52 Daily, Summer (Max) —————————————————— Off-Road Equipment 2.45 2.05 19.0 25.2 0.04 0.78 —0.78 0.72 —0.72 —4,270 4,270 0.17 0.03 —4,285 Onsite truck 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Daily, Winter (Max) —————————————————— Off-Road Equipment 2.45 2.05 19.0 25.2 0.04 0.78 —0.78 0.72 —0.72 —4,270 4,270 0.17 0.03 —4,285 Onsite truck 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Average Daily —————————————————— Off-Road Equipment 0.80 0.67 6.20 8.23 0.01 0.26 —0.26 0.24 —0.24 —1,396 1,396 0.06 0.01 —1,400 Onsite truck 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Annual —————————————————— Off-Road Equipment 0.15 0.12 1.13 1.50 < 0.005 0.05 —0.05 0.04 —0.04 —231 231 0.01 < 0.005 —232 Onsite truck 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Offsite —————————————————— Daily, Summer (Max) —————————————————— Worker 1.15 1.04 1.00 17.7 0.00 0.00 0.19 0.19 0.00 0.00 0.00 —3,201 3,201 0.13 0.11 11.9 3,250 Vendor 0.21 0.06 2.40 1.30 0.02 0.03 0.13 0.16 0.03 0.05 0.08 —2,159 2,159 0.17 0.33 6.08 2,267 Hauling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 20 / 52 ——————————————————Daily, Winter (Max) Worker 1.09 0.98 1.10 13.3 0.00 0.00 0.19 0.19 0.00 0.00 0.00 —2,935 2,935 0.14 0.11 0.31 2,972 Vendor 0.21 0.06 2.50 1.30 0.02 0.03 0.13 0.16 0.03 0.05 0.08 —2,161 2,161 0.17 0.33 0.16 2,262 Hauling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Average Daily —————————————————— Worker 0.35 0.31 0.39 4.60 0.00 0.00 0.06 0.06 0.00 0.00 0.00 —973 973 0.05 0.04 1.68 986 Vendor 0.07 0.02 0.82 0.42 0.01 0.01 0.04 0.05 0.01 0.02 0.03 —706 706 0.05 0.11 0.86 740 Hauling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Annual —————————————————— Worker 0.06 0.06 0.07 0.84 0.00 0.00 0.01 0.01 0.00 0.00 0.00 —161 161 0.01 0.01 0.28 163 Vendor 0.01 < 0.005 0.15 0.08 < 0.005 < 0.005 0.01 0.01 < 0.005 < 0.005 < 0.005 —117 117 0.01 0.02 0.14 123 Hauling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 3.11. Paving (2025) - Unmitigated Criteria Pollutants (lb/day for daily, ton/yr for annual) and GHGs (lb/day for daily, MT/yr for annual) Location TOG ROG NOx CO SO2 PM10E PM10D PM10T PM2.5E PM2.5D PM2.5T BCO2 NBCO2 CO2T CH4 N2O R CO2e Onsite —————————————————— Daily, Summer (Max) —————————————————— Off-Road Equipment 0.95 0.80 7.45 9.98 0.01 0.35 —0.35 0.32 —0.32 —1,511 1,511 0.06 0.01 —1,517 Paving —0.24 ———————————————— Onsite truck 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 21 / 52 ——————————————————Daily, Winter (Max) Off-Road Equipment 0.95 0.80 7.45 9.98 0.01 0.35 —0.35 0.32 —0.32 —1,511 1,511 0.06 0.01 —1,517 Paving —0.24 ———————————————— Onsite truck 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Average Daily —————————————————— Off-Road Equipment 0.23 0.20 1.84 2.46 < 0.005 0.09 —0.09 0.08 —0.08 —373 373 0.02 < 0.005 —374 Paving —0.06 ———————————————— Onsite truck 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Annual —————————————————— Off-Road Equipment 0.04 0.04 0.34 0.45 < 0.005 0.02 —0.02 0.01 —0.01 —61.7 61.7 < 0.005 < 0.005 —61.9 Paving —0.01 ———————————————— Onsite truck 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Offsite —————————————————— Daily, Summer (Max) —————————————————— Worker 0.08 0.07 0.07 1.17 0.00 0.00 0.01 0.01 0.00 0.00 0.00 —211 211 0.01 0.01 0.78 215 Vendor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Hauling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Daily, Winter (Max) —————————————————— Worker 0.07 0.06 0.07 0.88 0.00 0.00 0.01 0.01 0.00 0.00 0.00 —194 194 0.01 0.01 0.02 196 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 22 / 52 Vendor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Hauling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Average Daily —————————————————— Worker 0.02 0.02 0.02 0.23 0.00 0.00 < 0.005 < 0.005 0.00 0.00 0.00 —48.5 48.5 < 0.005 < 0.005 0.08 49.1 Vendor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Hauling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Annual —————————————————— Worker < 0.005 < 0.005 < 0.005 0.04 0.00 0.00 < 0.005 < 0.005 0.00 0.00 0.00 —8.02 8.02 < 0.005 < 0.005 0.01 8.14 Vendor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Hauling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 3.13. Architectural Coating (2025) - Unmitigated Criteria Pollutants (lb/day for daily, ton/yr for annual) and GHGs (lb/day for daily, MT/yr for annual) Location TOG ROG NOx CO SO2 PM10E PM10D PM10T PM2.5E PM2.5D PM2.5T BCO2 NBCO2 CO2T CH4 N2O R CO2e Onsite —————————————————— Daily, Summer (Max) —————————————————— Off-Road Equipment 0.21 0.17 1.18 1.52 < 0.005 0.04 —0.04 0.03 —0.03 —178 178 0.01 < 0.005 —179 Architect ural Coatings —44.3 ———————————————— Onsite truck 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Daily, Winter (Max) —————————————————— Off-Road Equipment 0.21 0.17 1.18 1.52 < 0.005 0.04 —0.04 0.03 —0.03 —178 178 0.01 < 0.005 —179 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 23 / 52 Architect Coatings —44.3 ———————————————— Onsite truck 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Average Daily —————————————————— Off-Road Equipment 0.03 0.03 0.19 0.25 < 0.005 0.01 —0.01 0.01 —0.01 —29.3 29.3 < 0.005 < 0.005 —29.4 Architect ural Coatings —7.29 ———————————————— Onsite truck 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Annual —————————————————— Off-Road Equipment 0.01 0.01 0.04 0.05 < 0.005 < 0.005 —< 0.005 < 0.005 —< 0.005 —4.85 4.85 < 0.005 < 0.005 —4.86 Architect ural Coatings —1.33 ———————————————— Onsite truck 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Offsite —————————————————— Daily, Summer (Max) —————————————————— Worker 0.23 0.21 0.20 3.54 0.00 0.00 0.04 0.04 0.00 0.00 0.00 —640 640 0.03 0.02 2.37 650 Vendor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Hauling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Daily, Winter (Max) —————————————————— Worker 0.22 0.20 0.22 2.67 0.00 0.00 0.04 0.04 0.00 0.00 0.00 —587 587 0.03 0.02 0.06 594 Vendor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 24 / 52 Hauling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Average Daily —————————————————— Worker 0.04 0.03 0.04 0.46 0.00 0.00 0.01 0.01 0.00 0.00 0.00 —97.8 97.8 < 0.005 < 0.005 0.17 99.2 Vendor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Hauling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Annual —————————————————— Worker 0.01 0.01 0.01 0.08 0.00 0.00 < 0.005 < 0.005 0.00 0.00 0.00 —16.2 16.2 < 0.005 < 0.005 0.03 16.4 Vendor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Hauling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 4. Operations Emissions Details 4.1. Mobile Emissions by Land Use 4.1.1. Unmitigated Criteria Pollutants (lb/day for daily, ton/yr for annual) and GHGs (lb/day for daily, MT/yr for annual) Land Use TOG ROG NOx CO SO2 PM10E PM10D PM10T PM2.5E PM2.5D PM2.5T BCO2 NBCO2 CO2T CH4 N2O R CO2e Daily, Summer (Max) —————————————————— Unrefrige rated Warehou se-No Rail 2.13 2.01 0.80 14.1 0.03 0.01 0.12 0.13 0.01 0.04 0.05 —2,626 2,626 0.14 0.09 9.23 2,664 Parking Lot 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Other Asphalt Surfaces 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 25 / 52 User Defined Industrial 3.00 0.68 30.1 17.1 0.26 0.42 2.21 2.64 0.41 0.72 1.12 —28,455 28,455 2.24 4.26 83.6 29,865 Total 5.12 2.69 30.9 31.2 0.28 0.44 2.33 2.77 0.42 0.75 1.17 —31,081 31,081 2.38 4.35 92.8 32,530 Daily, Winter (Max) —————————————————— Unrefrige rated Warehou se-No Rail 2.01 1.89 0.88 12.2 0.02 0.01 0.12 0.13 0.01 0.04 0.05 —2,423 2,423 0.15 0.09 0.24 2,454 Parking Lot 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Other Asphalt Surfaces 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 User Defined Industrial 2.97 0.66 31.5 17.1 0.26 0.42 2.21 2.64 0.41 0.72 1.12 —28,461 28,461 2.24 4.27 2.17 29,790 Total 4.99 2.55 32.4 29.3 0.28 0.44 2.33 2.77 0.42 0.75 1.17 —30,884 30,884 2.39 4.36 2.41 32,244 Annual —————————————————— Unrefrige rated Warehou se-No Rail 0.27 0.25 0.12 1.69 < 0.005 < 0.005 0.02 0.02 < 0.005 < 0.005 0.01 —297 297 0.02 0.01 0.48 302 Parking Lot 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 Other Asphalt Surfaces 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 0.00 0.00 0.00 0.00 User Defined Industrial 0.40 0.09 4.25 2.28 0.03 0.06 0.30 0.35 0.05 0.10 0.15 —3,447 3,447 0.27 0.52 4.37 3,613 Total 0.66 0.34 4.37 3.97 0.04 0.06 0.31 0.37 0.06 0.10 0.16 —3,745 3,745 0.29 0.53 4.86 3,914 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 26 / 52 4.2. Energy 4.2.1. Electricity Emissions By Land Use - Unmitigated Criteria Pollutants (lb/day for daily, ton/yr for annual) and GHGs (lb/day for daily, MT/yr for annual) Land Use TOG ROG NOx CO SO2 PM10E PM10D PM10T PM2.5E PM2.5D PM2.5T BCO2 NBCO2 CO2T CH4 N2O R CO2e Daily, Summer (Max) —————————————————— Unrefrige rated Warehou se-No Rail ————————————2,386 2,386 0.23 0.03 —2,400 Parking Lot ————————————130 130 0.01 < 0.005 —131 Other Asphalt Surfaces ————————————0.00 0.00 0.00 0.00 —0.00 User Defined Industrial ————————————0.00 0.00 0.00 0.00 —0.00 Total ————————————2,516 2,516 0.24 0.03 —2,530 Daily, Winter (Max) —————————————————— Unrefrige rated Warehou se-No Rail ————————————2,386 2,386 0.23 0.03 —2,400 Parking Lot ————————————130 130 0.01 < 0.005 —131 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 27 / 52 0.00—0.000.000.000.00————————————Other Asphalt Surfaces User Defined Industrial ————————————0.00 0.00 0.00 0.00 —0.00 Total ————————————2,516 2,516 0.24 0.03 —2,530 Annual —————————————————— Unrefrige rated Warehou se-No Rail ————————————395 395 0.04 < 0.005 —397 Parking Lot ————————————21.5 21.5 < 0.005 < 0.005 —21.6 Other Asphalt Surfaces ————————————0.00 0.00 0.00 0.00 —0.00 User Defined Industrial ————————————0.00 0.00 0.00 0.00 —0.00 Total ————————————417 417 0.04 < 0.005 —419 4.2.3. Natural Gas Emissions By Land Use - Unmitigated Criteria Pollutants (lb/day for daily, ton/yr for annual) and GHGs (lb/day for daily, MT/yr for annual) Land Use TOG ROG NOx CO SO2 PM10E PM10D PM10T PM2.5E PM2.5D PM2.5T BCO2 NBCO2 CO2T CH4 N2O R CO2e Daily, Summer (Max) —————————————————— Unrefrige rated Warehou se-No Rail 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 —0.00 —0.00 0.00 0.00 0.00 —0.00 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 28 / 52 Parking Lot 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 —0.00 —0.00 0.00 0.00 0.00 —0.00 Other Asphalt Surfaces 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 —0.00 —0.00 0.00 0.00 0.00 —0.00 User Defined Industrial 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 —0.00 —0.00 0.00 0.00 0.00 —0.00 Total 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 —0.00 —0.00 0.00 0.00 0.00 —0.00 Daily, Winter (Max) —————————————————— Unrefrige rated Warehou se-No Rail 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 —0.00 —0.00 0.00 0.00 0.00 —0.00 Parking Lot 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 —0.00 —0.00 0.00 0.00 0.00 —0.00 Other Asphalt Surfaces 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 —0.00 —0.00 0.00 0.00 0.00 —0.00 User Defined Industrial 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 —0.00 —0.00 0.00 0.00 0.00 —0.00 Total 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 —0.00 —0.00 0.00 0.00 0.00 —0.00 Annual —————————————————— Unrefrige rated Warehou se-No Rail 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 —0.00 —0.00 0.00 0.00 0.00 —0.00 Parking Lot 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 —0.00 —0.00 0.00 0.00 0.00 —0.00 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 29 / 52 0.00—0.000.000.000.00—0.00—0.000.00—0.000.000.000.000.000.00Other Asphalt Surfaces User Defined Industrial 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 —0.00 —0.00 0.00 0.00 0.00 —0.00 Total 0.00 0.00 0.00 0.00 0.00 0.00 —0.00 0.00 —0.00 —0.00 0.00 0.00 0.00 —0.00 4.3. Area Emissions by Source 4.3.2. Unmitigated Criteria Pollutants (lb/day for daily, ton/yr for annual) and GHGs (lb/day for daily, MT/yr for annual) Source TOG ROG NOx CO SO2 PM10E PM10D PM10T PM2.5E PM2.5D PM2.5T BCO2 NBCO2 CO2T CH4 N2O R CO2e Daily, Summer (Max) —————————————————— Architect ural Coatings —45.8 ———————————————— Consum er Products —11.6 ———————————————— Landsca pe Equipme nt 4.18 3.86 0.20 23.5 < 0.005 0.03 —0.03 0.04 —0.04 —96.7 96.7 < 0.005 < 0.005 —97.1 Total 4.18 61.2 0.20 23.5 < 0.005 0.03 —0.03 0.04 —0.04 —96.7 96.7 < 0.005 < 0.005 —97.1 Daily, Winter (Max) —————————————————— Architect ural Coatings —45.8 ———————————————— 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 30 / 52 ————————————————11.6—Consum er Total —57.4 ———————————————— Annual —————————————————— Architect ural Coatings —1.59 ———————————————— Consum er Products —2.12 ———————————————— Landsca pe Equipme nt 0.52 0.48 0.02 2.94 < 0.005 < 0.005 —< 0.005 0.01 —0.01 —11.0 11.0 < 0.005 < 0.005 —11.0 Total 0.52 4.19 0.02 2.94 < 0.005 < 0.005 —< 0.005 0.01 —0.01 —11.0 11.0 < 0.005 < 0.005 —11.0 4.4. Water Emissions by Land Use 4.4.2. Unmitigated Criteria Pollutants (lb/day for daily, ton/yr for annual) and GHGs (lb/day for daily, MT/yr for annual) Land Use TOG ROG NOx CO SO2 PM10E PM10D PM10T PM2.5E PM2.5D PM2.5T BCO2 NBCO2 CO2T CH4 N2O R CO2e Daily, Summer (Max) —————————————————— Unrefrige rated Warehou se-No Rail ———————————240 826 1,066 24.7 0.59 —1,859 Parking Lot ———————————0.00 0.00 0.00 0.00 0.00 —0.00 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 31 / 52 0.00—0.000.000.000.000.00———————————Other Asphalt Surfaces User Defined Industrial ———————————0.00 0.00 0.00 0.00 0.00 —0.00 Total ———————————240 826 1,066 24.7 0.59 —1,859 Daily, Winter (Max) —————————————————— Unrefrige rated Warehou se-No Rail ———————————240 826 1,066 24.7 0.59 —1,859 Parking Lot ———————————0.00 0.00 0.00 0.00 0.00 —0.00 Other Asphalt Surfaces ———————————0.00 0.00 0.00 0.00 0.00 —0.00 User Defined Industrial ———————————0.00 0.00 0.00 0.00 0.00 —0.00 Total ———————————240 826 1,066 24.7 0.59 —1,859 Annual —————————————————— Unrefrige rated Warehou se-No Rail ———————————39.7 137 176 4.08 0.10 —308 Parking Lot ———————————0.00 0.00 0.00 0.00 0.00 —0.00 Other Asphalt Surfaces ———————————0.00 0.00 0.00 0.00 0.00 —0.00 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 32 / 52 0.00—0.000.000.000.000.00———————————User Defined Industrial Total ———————————39.7 137 176 4.08 0.10 —308 4.5. Waste Emissions by Land Use 4.5.2. Unmitigated Criteria Pollutants (lb/day for daily, ton/yr for annual) and GHGs (lb/day for daily, MT/yr for annual) Land Use TOG ROG NOx CO SO2 PM10E PM10D PM10T PM2.5E PM2.5D PM2.5T BCO2 NBCO2 CO2T CH4 N2O R CO2e Daily, Summer (Max) —————————————————— Unrefrige rated Warehou se-No Rail ———————————274 0.00 274 27.4 0.00 —959 Parking Lot ———————————0.00 0.00 0.00 0.00 0.00 —0.00 Other Asphalt Surfaces ———————————0.00 0.00 0.00 0.00 0.00 —0.00 User Defined Industrial ———————————0.00 0.00 0.00 0.00 0.00 —0.00 Total ———————————274 0.00 274 27.4 0.00 —959 Daily, Winter (Max) —————————————————— 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 33 / 52 959—0.0027.42740.00274———————————Unrefrige rated Warehou se-No Rail Parking Lot ———————————0.00 0.00 0.00 0.00 0.00 —0.00 Other Asphalt Surfaces ———————————0.00 0.00 0.00 0.00 0.00 —0.00 User Defined Industrial ———————————0.00 0.00 0.00 0.00 0.00 —0.00 Total ———————————274 0.00 274 27.4 0.00 —959 Annual —————————————————— Unrefrige rated Warehou se-No Rail ———————————45.4 0.00 45.4 4.53 0.00 —159 Parking Lot ———————————0.00 0.00 0.00 0.00 0.00 —0.00 Other Asphalt Surfaces ———————————0.00 0.00 0.00 0.00 0.00 —0.00 User Defined Industrial ———————————0.00 0.00 0.00 0.00 0.00 —0.00 Total ———————————45.4 0.00 45.4 4.53 0.00 —159 4.6. Refrigerant Emissions by Land Use 4.6.1. Unmitigated Criteria Pollutants (lb/day for daily, ton/yr for annual) and GHGs (lb/day for daily, MT/yr for annual) 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 34 / 52 Land Use TOG ROG NOx CO SO2 PM10E PM10D PM10T PM2.5E PM2.5D PM2.5T BCO2 NBCO2 CO2T CH4 N2O R CO2e Daily, Summer (Max) —————————————————— Total —————————————————— Daily, Winter (Max) —————————————————— Total —————————————————— Annual —————————————————— Total —————————————————— 4.7. Offroad Emissions By Equipment Type 4.7.1. Unmitigated Criteria Pollutants (lb/day for daily, ton/yr for annual) and GHGs (lb/day for daily, MT/yr for annual) Equipme nt Type TOG ROG NOx CO SO2 PM10E PM10D PM10T PM2.5E PM2.5D PM2.5T BCO2 NBCO2 CO2T CH4 N2O R CO2e Daily, Summer (Max) —————————————————— Total —————————————————— Daily, Winter (Max) —————————————————— Total —————————————————— Annual —————————————————— Total —————————————————— 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 35 / 52 4.8. Stationary Emissions By Equipment Type 4.8.1. Unmitigated Criteria Pollutants (lb/day for daily, ton/yr for annual) and GHGs (lb/day for daily, MT/yr for annual) Equipme nt Type TOG ROG NOx CO SO2 PM10E PM10D PM10T PM2.5E PM2.5D PM2.5T BCO2 NBCO2 CO2T CH4 N2O R CO2e Daily, Summer (Max) —————————————————— Total —————————————————— Daily, Winter (Max) —————————————————— Total —————————————————— Annual —————————————————— Total —————————————————— 4.9. User Defined Emissions By Equipment Type 4.9.1. Unmitigated Criteria Pollutants (lb/day for daily, ton/yr for annual) and GHGs (lb/day for daily, MT/yr for annual) Equipme nt Type TOG ROG NOx CO SO2 PM10E PM10D PM10T PM2.5E PM2.5D PM2.5T BCO2 NBCO2 CO2T CH4 N2O R CO2e Daily, Summer (Max) —————————————————— Total —————————————————— Daily, Winter (Max) —————————————————— 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 36 / 52 Total —————————————————— Annual —————————————————— Total —————————————————— 4.10. Soil Carbon Accumulation By Vegetation Type 4.10.1. Soil Carbon Accumulation By Vegetation Type - Unmitigated Criteria Pollutants (lb/day for daily, ton/yr for annual) and GHGs (lb/day for daily, MT/yr for annual) Vegetatio n TOG ROG NOx CO SO2 PM10E PM10D PM10T PM2.5E PM2.5D PM2.5T BCO2 NBCO2 CO2T CH4 N2O R CO2e Daily, Summer (Max) —————————————————— Total —————————————————— Daily, Winter (Max) —————————————————— Total —————————————————— Annual —————————————————— Total —————————————————— 4.10.2. Above and Belowground Carbon Accumulation by Land Use Type - Unmitigated Criteria Pollutants (lb/day for daily, ton/yr for annual) and GHGs (lb/day for daily, MT/yr for annual) Land Use TOG ROG NOx CO SO2 PM10E PM10D PM10T PM2.5E PM2.5D PM2.5T BCO2 NBCO2 CO2T CH4 N2O R CO2e Daily, Summer (Max) —————————————————— Total —————————————————— 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 37 / 52 ——————————————————Daily, Winter (Max) Total —————————————————— Annual —————————————————— Total —————————————————— 4.10.3. Avoided and Sequestered Emissions by Species - Unmitigated Criteria Pollutants (lb/day for daily, ton/yr for annual) and GHGs (lb/day for daily, MT/yr for annual) Species TOG ROG NOx CO SO2 PM10E PM10D PM10T PM2.5E PM2.5D PM2.5T BCO2 NBCO2 CO2T CH4 N2O R CO2e Daily, Summer (Max) —————————————————— Avoided —————————————————— Subtotal —————————————————— Sequest ered —————————————————— Subtotal —————————————————— Remove d —————————————————— Subtotal —————————————————— ——————————————————— Daily, Winter (Max) —————————————————— Avoided —————————————————— Subtotal —————————————————— Sequest ered —————————————————— Subtotal —————————————————— 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 38 / 52 ——————————————————Remove d Subtotal —————————————————— ——————————————————— Annual —————————————————— Avoided —————————————————— Subtotal —————————————————— Sequest ered —————————————————— Subtotal —————————————————— Remove d —————————————————— Subtotal —————————————————— ——————————————————— 5. Activity Data 5.1. Construction Schedule Phase Name Phase Type Start Date End Date Days Per Week Work Days per Phase Phase Description Demolition Demolition 1/1/2024 1/29/2024 5.00 20.0 — Site Preparation Site Preparation 1/30/2024 3/11/2024 5.00 30.0 — Grading Grading 3/12/2024 4/22/2024 5.00 30.0 — Building Construction Building Construction 4/23/2024 6/16/2025 5.00 300 — Paving Paving 2/11/2025 6/16/2025 5.00 90.0 — Architectural Coating Architectural Coating 3/25/2025 6/16/2025 5.00 60.0 — 5.2. Off-Road Equipment 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 39 / 52 5.2.1. Unmitigated Phase Name Equipment Type Fuel Type Engine Tier Number per Day Hours Per Day Horsepower Load Factor Demolition Concrete/Industrial Saws Diesel Average 1.00 8.00 33.0 0.73 Demolition Excavators Diesel Average 3.00 8.00 36.0 0.38 Demolition Rubber Tired Dozers Diesel Average 2.00 8.00 367 0.40 Site Preparation Rubber Tired Dozers Diesel Average 3.00 8.00 367 0.40 Grading Excavators Diesel Average 2.00 8.00 36.0 0.38 Grading Graders Diesel Average 1.00 8.00 148 0.41 Grading Rubber Tired Dozers Diesel Average 1.00 8.00 367 0.40 Grading Scrapers Diesel Average 2.00 8.00 423 0.48 Building Construction Cranes Diesel Average 1.00 8.00 367 0.29 Building Construction Forklifts Diesel Average 6.00 8.00 82.0 0.20 Building Construction Generator Sets Diesel Average 2.00 8.00 14.0 0.74 Building Construction Tractors/Loaders/Backh oes Diesel Average 6.00 8.00 84.0 0.37 Building Construction Welders Diesel Average 2.00 8.00 46.0 0.45 Paving Pavers Diesel Average 2.00 8.00 81.0 0.42 Paving Paving Equipment Diesel Average 2.00 8.00 89.0 0.36 Paving Rollers Diesel Average 2.00 8.00 36.0 0.38 Architectural Coating Air Compressors Diesel Average 1.00 8.00 37.0 0.48 Site Preparation Crawler Tractors Diesel Average 4.00 8.00 87.0 0.43 Grading Crawler Tractors Diesel Average 2.00 8.00 87.0 0.43 5.3. Construction Vehicles 5.3.1. Unmitigated 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 40 / 52 Phase Name Trip Type One-Way Trips per Day Miles per Trip Vehicle Mix Demolition ———— Demolition Worker 15.0 18.5 LDA,LDT1,LDT2 Demolition Vendor 5.00 10.2 HHDT,MHDT Demolition Hauling 15.8 20.0 HHDT Demolition Onsite truck ——HHDT Site Preparation ———— Site Preparation Worker 17.5 18.5 LDA,LDT1,LDT2 Site Preparation Vendor 7.00 10.2 HHDT,MHDT Site Preparation Hauling 0.00 20.0 HHDT Site Preparation Onsite truck ——HHDT Grading ———— Grading Worker 20.0 18.5 LDA,LDT1,LDT2 Grading Vendor 7.00 10.2 HHDT,MHDT Grading Hauling 0.00 20.0 HHDT Grading Onsite truck ——HHDT Building Construction ———— Building Construction Worker 227 18.5 LDA,LDT1,LDT2 Building Construction Vendor 70.0 10.2 HHDT,MHDT Building Construction Hauling 0.00 20.0 HHDT Building Construction Onsite truck ——HHDT Paving ———— Paving Worker 15.0 18.5 LDA,LDT1,LDT2 Paving Vendor 0.00 10.2 HHDT,MHDT Paving Hauling 0.00 20.0 HHDT Paving Onsite truck ——HHDT Architectural Coating ———— 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 41 / 52 Architectural Coating Worker 45.4 18.5 LDA,LDT1,LDT2 Architectural Coating Vendor 0.00 10.2 HHDT,MHDT Architectural Coating Hauling 0.00 20.0 HHDT Architectural Coating Onsite truck ——HHDT 5.4. Vehicles 5.4.1. Construction Vehicle Control Strategies Non-applicable. No control strategies activated by user. 5.5. Architectural Coatings Phase Name Residential Interior Area Coated (sq ft) Residential Exterior Area Coated (sq ft) Non-Residential Interior Area Coated (sq ft) Non-Residential Exterior Area Coated (sq ft) Parking Area Coated (sq ft) Architectural Coating 0.00 0.00 827,649 275,883 21,834 5.6. Dust Mitigation 5.6.1. Construction Earthmoving Activities Phase Name Material Imported (cy)Material Exported (cy)Acres Graded (acres)Material Demolished (Building Square Footage) Acres Paved (acres) Demolition 0.00 0.00 0.00 27,454 — Site Preparation ——105 0.00 — Grading ——120 0.00 — Paving 0.00 0.00 0.00 0.00 8.35 5.6.2. Construction Earthmoving Control Strategies Control Strategies Applied Frequency (per day)PM10 Reduction PM2.5 Reduction Water Exposed Area 3 74%74% 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 42 / 52 Water Demolished Area 2 36%36% 5.7. Construction Paving Land Use Area Paved (acres)% Asphalt Unrefrigerated Warehouse-No Rail 0.00 0% Parking Lot 3.56 100% Other Asphalt Surfaces 4.79 100% User Defined Industrial 0.00 0% 5.8. Construction Electricity Consumption and Emissions Factors kWh per Year and Emission Factor (lb/MWh) Year kWh per Year CO2 CH4 N2O 2024 0.00 349 0.03 < 0.005 2025 0.00 349 0.03 < 0.005 5.9. Operational Mobile Sources 5.9.1. Unmitigated Land Use Type Trips/Weekday Trips/Saturday Trips/Sunday Trips/Year VMT/Weekday VMT/Saturday VMT/Sunday VMT/Year Unrefrigerated Warehouse-No Rail 600 52.5 21.1 160,212 3,501 306 123 935,159 Parking Lot 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Other Asphalt Surfaces 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 User Defined Industrial 328 28.7 11.4 87,537 9,954 871 345 2,658,504 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 43 / 52 5.10. Operational Area Sources 5.10.1. Hearths 5.10.1.1. Unmitigated 5.10.2. Architectural Coatings Residential Interior Area Coated (sq ft)Residential Exterior Area Coated (sq ft)Non-Residential Interior Area Coated (sq ft) Non-Residential Exterior Area Coated (sq ft) Parking Area Coated (sq ft) 0 0.00 827,649 275,883 21,834 5.10.3. Landscape Equipment Season Unit Value Snow Days day/yr 0.00 Summer Days day/yr 250 5.11. Operational Energy Consumption 5.11.1. Unmitigated Electricity (kWh/yr) and CO2 and CH4 and N2O and Natural Gas (kBTU/yr) Land Use Electricity (kWh/yr)CO2 CH4 N2O Natural Gas (kBTU/yr) Unrefrigerated Warehouse-No Rail 2,498,021 349 0.0330 0.0040 0.00 Parking Lot 135,997 349 0.0330 0.0040 0.00 Other Asphalt Surfaces 0.00 349 0.0330 0.0040 0.00 User Defined Industrial 0.00 349 0.0330 0.0040 0.00 5.12. Operational Water and Wastewater Consumption 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 44 / 52 5.12.1. Unmitigated Land Use Indoor Water (gal/year)Outdoor Water (gal/year) Unrefrigerated Warehouse-No Rail 125,071,331 2,563,454 Parking Lot 0.00 0.00 Other Asphalt Surfaces 0.00 0.00 User Defined Industrial 0.00 0.00 5.13. Operational Waste Generation 5.13.1. Unmitigated Land Use Waste (ton/year)Cogeneration (kWh/year) Unrefrigerated Warehouse-No Rail 508 0.00 Parking Lot 0.00 0.00 Other Asphalt Surfaces 0.00 0.00 User Defined Industrial 0.00 0.00 5.14. Operational Refrigeration and Air Conditioning Equipment 5.14.1. Unmitigated Land Use Type Equipment Type Refrigerant GWP Quantity (kg)Operations Leak Rate Service Leak Rate Times Serviced 5.15. Operational Off-Road Equipment 5.15.1. Unmitigated Equipment Type Fuel Type Engine Tier Number per Day Hours Per Day Horsepower Load Factor 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 45 / 52 5.16. Stationary Sources 5.16.1. Emergency Generators and Fire Pumps Equipment Type Fuel Type Number per Day Hours per Day Hours per Year Horsepower Load Factor 5.16.2. Process Boilers Equipment Type Fuel Type Number Boiler Rating (MMBtu/hr)Daily Heat Input (MMBtu/day)Annual Heat Input (MMBtu/yr) 5.17. User Defined Equipment Type Fuel Type —— 5.18. Vegetation 5.18.1. Land Use Change 5.18.1.1. Unmitigated Vegetation Land Use Type Vegetation Soil Type Initial Acres Final Acres 5.18.1. Biomass Cover Type 5.18.1.1. Unmitigated Biomass Cover Type Initial Acres Final Acres 5.18.2. Sequestration 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 46 / 52 5.18.2.1. Unmitigated Tree Type Number Electricity Saved (kWh/year)Natural Gas Saved (btu/year) 6. Climate Risk Detailed Report 6.1. Climate Risk Summary Cal-Adapt midcentury 2040–2059 average projections for four hazards are reported below for your project location. These are under Representation Concentration Pathway (RCP) 8.5 which assumes GHG emissions will continue to rise strongly through 2050 and then plateau around 2100. Climate Hazard Result for Project Location Unit Temperature and Extreme Heat 24.4 annual days of extreme heat Extreme Precipitation 3.50 annual days with precipitation above 20 mm Sea Level Rise 0.00 meters of inundation depth Wildfire 6.13 annual hectares burned Temperature and Extreme Heat data are for grid cell in which your project are located. The projection is based on the 98th historical percentile of daily maximum/minimum temperatures from observed historical data (32 climate model ensemble from Cal-Adapt, 2040–2059 average under RCP 8.5). Each grid cell is 6 kilometers (km) by 6 km, or 3.7 miles (mi) by 3.7 mi. Extreme Precipitation data are for the grid cell in which your project are located. The threshold of 20 mm is equivalent to about ¾ an inch of rain, which would be light to moderate rainfall if received over a full day or heavy rain if received over a period of 2 to 4 hours. Each grid cell is 6 kilometers (km) by 6 km, or 3.7 miles (mi) by 3.7 mi. Sea Level Rise data are for the grid cell in which your project are located. The projections are from Radke et al. (2017), as reported in Cal-Adapt (2040–2059 average under RCP 8.5), and consider different increments of sea level rise coupled with extreme storm events. Users may select from four model simulations to view the range in potential inundation depth for the grid cell. The four simulations make different assumptions about expected rainfall and temperature are: Warmer/drier (HadGEM2-ES), Cooler/wetter (CNRM-CM5), Average conditions (CanESM2), Range of different rainfall and temperature possibilities (MIROC5). Each grid cell is 50 meters (m) by 50 m, or about 164 feet (ft) by 164 ft. Wildfire data are for the grid cell in which your project are located. The projections are from UC Davis, as reported in Cal-Adapt (2040–2059 average under RCP 8.5), and consider historical data of climate, vegetation, population density, and large (> 400 ha) fire history. Users may select from four model simulations to view the range in potential wildfire probabilities for the grid cell. The four simulations make different assumptions about expected rainfall and temperature are: Warmer/drier (HadGEM2-ES), Cooler/wetter (CNRM-CM5), Average conditions (CanESM2), Range of different rainfall and temperature possibilities (MIROC5). Each grid cell is 6 kilometers (km) by 6 km, or 3.7 miles (mi) by 3.7 mi. 6.2. Initial Climate Risk Scores Climate Hazard Exposure Score Sensitivity Score Adaptive Capacity Score Vulnerability Score Temperature and Extreme Heat 3 0 0 N/A Extreme Precipitation N/A N/A N/A N/A Sea Level Rise 1 0 0 N/A 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 47 / 52 Wildfire 1 0 0 N/A Flooding N/A N/A N/A N/A Drought N/A N/A N/A N/A Snowpack N/A N/A N/A N/A Air Quality 0 0 0 N/A The sensitivity score reflects the extent to which a project would be adversely affected by exposure to a climate hazard. Exposure is rated on a scale of 1 to 5, with a score of 5 representing the greatest exposure. The adaptive capacity of a project refers to its ability to manage and reduce vulnerabilities from projected climate hazards. Adaptive capacity is rated on a scale of 1 to 5, with a score of 5 representing the greatest ability to adapt. The overall vulnerability scores are calculated based on the potential impacts and adaptive capacity assessments for each hazard. Scores do not include implementation of climate risk reduction measures. 6.3. Adjusted Climate Risk Scores Climate Hazard Exposure Score Sensitivity Score Adaptive Capacity Score Vulnerability Score Temperature and Extreme Heat 3 1 1 3 Extreme Precipitation N/A N/A N/A N/A Sea Level Rise 1 1 1 2 Wildfire 1 1 1 2 Flooding N/A N/A N/A N/A Drought N/A N/A N/A N/A Snowpack N/A N/A N/A N/A Air Quality 1 1 1 2 The sensitivity score reflects the extent to which a project would be adversely affected by exposure to a climate hazard. Exposure is rated on a scale of 1 to 5, with a score of 5 representing the greatest exposure. The adaptive capacity of a project refers to its ability to manage and reduce vulnerabilities from projected climate hazards. Adaptive capacity is rated on a scale of 1 to 5, with a score of 5 representing the greatest ability to adapt. The overall vulnerability scores are calculated based on the potential impacts and adaptive capacity assessments for each hazard. Scores include implementation of climate risk reduction measures. 6.4. Climate Risk Reduction Measures 7. Health and Equity Details 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 48 / 52 7.1. CalEnviroScreen 4.0 Scores The maximum CalEnviroScreen score is 100. A high score (i.e., greater than 50) reflects a higher pollution burden compared to other census tracts in the state. Indicator Result for Project Census Tract Exposure Indicators — AQ-Ozone 95.3 AQ-PM 93.5 AQ-DPM 78.3 Drinking Water 96.1 Lead Risk Housing 42.2 Pesticides 18.1 Toxic Releases 84.6 Traffic 79.6 Effect Indicators — CleanUp Sites 82.7 Groundwater 14.3 Haz Waste Facilities/Generators 94.4 Impaired Water Bodies 0.00 Solid Waste 87.1 Sensitive Population — Asthma 44.4 Cardio-vascular 55.1 Low Birth Weights 20.3 Socioeconomic Factor Indicators — Education 73.4 Housing 26.7 Linguistic 34.6 Poverty 51.4 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 49 / 52 Unemployment 51.3 7.2. Healthy Places Index Scores The maximum Health Places Index score is 100. A high score (i.e., greater than 50) reflects healthier community conditions compared to other census tracts in the state. Indicator Result for Project Census Tract Economic — Above Poverty 46.27229565 Employed 32.144232 Education — Bachelor's or higher 30.92518927 High school enrollment 27.47337354 Preschool enrollment 9.149236494 Transportation — Auto Access 75.69613756 Active commuting 25.30476068 Social — 2-parent households 83.85730784 Voting 30.59155653 Neighborhood — Alcohol availability 69.20313102 Park access 26.03618632 Retail density 30.7583729 Supermarket access 43.14128064 Tree canopy 6.390350314 Housing — Homeownership 72.5009624 Housing habitability 80.9829334 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 50 / 52 Low-inc homeowner severe housing cost burden 33.8380598 Low-inc renter severe housing cost burden 97.78005903 Uncrowded housing 24.76581548 Health Outcomes — Insured adults 19.91530861 Arthritis 67.1 Asthma ER Admissions 64.4 High Blood Pressure 71.3 Cancer (excluding skin)74.5 Asthma 37.3 Coronary Heart Disease 66.7 Chronic Obstructive Pulmonary Disease 53.7 Diagnosed Diabetes 40.6 Life Expectancy at Birth 53.2 Cognitively Disabled 21.0 Physically Disabled 18.0 Heart Attack ER Admissions 49.4 Mental Health Not Good 35.7 Chronic Kidney Disease 55.3 Obesity 33.9 Pedestrian Injuries 62.8 Physical Health Not Good 37.9 Stroke 58.2 Health Risk Behaviors — Binge Drinking 36.9 Current Smoker 40.0 No Leisure Time for Physical Activity 38.5 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 51 / 52 Climate Change Exposures — Wildfire Risk 0.0 SLR Inundation Area 0.0 Children 32.5 Elderly 76.6 English Speaking 56.0 Foreign-born 61.6 Outdoor Workers 45.8 Climate Change Adaptive Capacity — Impervious Surface Cover 67.8 Traffic Density 81.5 Traffic Access 23.0 Other Indices — Hardship 66.3 Other Decision Support — 2016 Voting 50.4 7.3. Overall Health & Equity Scores Metric Result for Project Census Tract CalEnviroScreen 4.0 Score for Project Location (a)71.0 Healthy Places Index Score for Project Location (b)40.0 Project Located in a Designated Disadvantaged Community (Senate Bill 535)No Project Located in a Low-Income Community (Assembly Bill 1550)No Project Located in a Community Air Protection Program Community (Assembly Bill 617)No a: The maximum CalEnviroScreen score is 100. A high score (i.e., greater than 50) reflects a higher pollution burden compared to other census tracts in the state. b: The maximum Health Places Index score is 100. A high score (i.e., greater than 50) reflects healthier community conditions compared to other census tracts in the state. 14581 Oleander and Santa Ana Detailed Report, 9/13/2022 52 / 52 7.4. Health & Equity Measures No Health & Equity Measures selected. 7.5. Evaluation Scorecard Health and Equity Evaluation Scorecard not completed. 8. User Changes to Default Data Screen Justification Construction: Off-Road Equipment All equipment will operate for 8 hours per day. Equipment based on data provided by the Project team. Construction: Trips and VMT Vendor trips adjusted based on construction phase length Construction: Architectural Coatings Rule 1113 Operations: Vehicle Data Vehicle data based on Project traffic study Operations: Fleet Mix Fleet mix based on Project traffic study Operations: Energy Use Project will not use natural gas Operations: Refrigerants Project does not include cold storage Construction: Construction Phases Construction schedule based on data provided by the Project team. Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report This page intentionally left blank Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report APPENDIX 4.2: EMFAC2021 Source: EMFAC2021 (v1.0.2) Emissions Inventory Region Type: Sub-Area Region: San Bernardino (SC) Calendar Year: 2024 Season: Annual Vehicle Classification: EMFAC2007 Categories Units: miles/day for CVMT and EVMT, trips/day for Trips, kWh/day for Energy Consumption, tons/day for Emissions, 1000 gallons/day for Fuel Consumption Region endar Yehicle Catego Model Year Speed Fuel Population Total VMT Fuel_Consumption (1000 gal)Fuel_Consumption (gal)Total Fuel VMT Total VMT Miles per Gallon Vehicle Class San Bernardino (SC)2024 HHDT Aggregate Aggregate Gasoline 5.565987525 200.7100937 0.053685222 53.68522156 320576.6084 200.7100937 1931561.832 6.03 HHDT San Bernardino (SC)2024 HHDT Aggregate Aggregate Diesel 14231.95658 1766161.303 294.8811952 294881.1952 1766161.303 San Bernardino (SC)2024 HHDT Aggregate Aggregate Electricity 48.62871821 4853.771805 0 0 4853.771805 San Bernardino (SC)2024 HHDT Aggregate Aggregate Natural Gas 2469.470738 160346.0479 25.64172796 25641.72796 160346.0479 San Bernardino (SC)2024 LDA Aggregate Aggregate Gasoline 459317.1397 20167734.04 678.0067332 678006.7332 689480.9135 20167734.04 21769357.53 31.57 LDA San Bernardino (SC)2024 LDA Aggregate Aggregate Diesel 1047.589492 37687.90898 0.878080701 878.0807006 37687.90898 San Bernardino (SC)2024 LDA Aggregate Aggregate Electricity 19287.2826 922159.8322 0 0 922159.8322 San Bernardino (SC)2024 LDA Aggregate Aggregate Plug-in Hybrid 12500.45848 641775.7563 10.5960996 10596.0996 641775.7563 San Bernardino (SC)2024 LDT1 Aggregate Aggregate Gasoline 40725.35771 1412436.812 57.61437754 57614.37754 57660.77698 1412436.812 1417994.863 24.59 LDT1 San Bernardino (SC)2024 LDT1 Aggregate Aggregate Diesel 10.72175816 158.8104429 0.006542477 6.542476778 158.8104429 San Bernardino (SC)2024 LDT1 Aggregate Aggregate Electricity 58.29951204 2744.162081 0 0 2744.162081 San Bernardino (SC)2024 LDT1 Aggregate Aggregate Plug-in Hybrid 51.79076029 2655.077851 0.039856963 39.85696305 2655.077851 San Bernardino (SC)2024 LDT2 Aggregate Aggregate Gasoline 192654.7494 7946861.936 328.2807397 328280.7397 330225.39 7946861.936 8092457.996 24.51 LDT2 San Bernardino (SC)2024 LDT2 Aggregate Aggregate Diesel 520.896721 23279.78377 0.7022627 702.2627003 23279.78377 San Bernardino (SC)2024 LDT2 Aggregate Aggregate Electricity 1199.246991 43242.4945 0 0 43242.4945 San Bernardino (SC)2024 LDT2 Aggregate Aggregate Plug-in Hybrid 1594.625518 79073.78143 1.24238757 1242.38757 79073.78143 San Bernardino (SC)2024 LHDT1 Aggregate Aggregate Gasoline 17179.49082 637558.6823 46.93129933 46931.29933 68120.12603 637558.6823 1077239.622 15.81 LHDT1 San Bernardino (SC)2024 LHDT1 Aggregate Aggregate Diesel 11382.09786 435758.4326 21.1888267 21188.8267 435758.4326 San Bernardino (SC)2024 LHDT1 Aggregate Aggregate Electricity 52.7403112 3922.506902 0 0 19386.27641 3922.506902 290170.8153 14.97 LHDT2 San Bernardino (SC)2024 LHDT2 Aggregate Aggregate Gasoline 2883.702401 102543.2335 8.523099836 8523.099836 102543.2335 San Bernardino (SC)2024 LHDT2 Aggregate Aggregate Diesel 4825.532255 186665.6444 10.86317658 10863.17658 2946.367925 186665.6444 123685.0541 41.98 MCY San Bernardino (SC)2024 LHDT2 Aggregate Aggregate Electricity 13.65084178 961.9374735 0 0 300889.4492 961.9374735 6007732.23 19.97 MDV San Bernardino (SC)2024 MCY Aggregate Aggregate Gasoline 20751.92893 123685.0541 2.946367925 2946.367925 123685.0541 San Bernardino (SC)2024 MDV Aggregate Aggregate Gasoline 147141.1277 5830683.861 296.7902416 296790.2416 5830683.861 San Bernardino (SC)2024 MDV Aggregate Aggregate Diesel 1910.88318 77417.93798 3.254905083 3254.905083 77417.93798 San Bernardino (SC)2024 MDV Aggregate Aggregate Electricity 1327.48959 47850.30724 0 0 7364.77817 47850.30724 42284.2868 5.74 MH San Bernardino (SC)2024 MDV Aggregate Aggregate Plug-in Hybrid 1028.690257 51780.12453 0.844302537 844.3025368 51780.12453 San Bernardino (SC)2024 MH Aggregate Aggregate Gasoline 3401.970527 30215.87901 6.184856876 6184.856876 88813.34178 30215.87901 740808.1193 8.34 MHDT San Bernardino (SC)2024 MH Aggregate Aggregate Diesel 1336.39751 12068.40778 1.179921294 1179.921294 12068.40778 San Bernardino (SC)2024 MHDT Aggregate Aggregate Gasoline 1460.602089 78395.7093 15.05623591 15056.23591 78395.7093 San Bernardino (SC)2024 MHDT Aggregate Aggregate Diesel 14946.4736 650565.6856 72.65830331 72658.30331 650565.6856 San Bernardino (SC)2024 MHDT Aggregate Aggregate Electricity 46.13645649 2344.169726 0 0 5378.066575 2344.169726 33062.62008 6.15 OBUS San Bernardino (SC)2024 MHDT Aggregate Aggregate Natural Gas 195.6757264 9502.554663 1.098802564 1098.802564 9502.554663 San Bernardino (SC)2024 OBUS Aggregate Aggregate Gasoline 370.0192137 15806.92249 3.09514692 3095.14692 15806.92249 San Bernardino (SC)2024 OBUS Aggregate Aggregate Diesel 210.5519789 15196.96791 2.055015596 2055.015596 4951.794465 15196.96791 31836.21175 6.43 SBUS San Bernardino (SC)2024 OBUS Aggregate Aggregate Electricity 0.809761934 65.22582716 0 0 65.22582716 San Bernardino (SC)2024 OBUS Aggregate Aggregate Natural Gas 32.78528924 1993.503854 0.227904058 227.9040581 1993.503854 San Bernardino (SC)2024 SBUS Aggregate Aggregate Gasoline 297.8692006 14022.10243 1.564009513 1564.009513 14022.10243 San Bernardino (SC)2024 SBUS Aggregate Aggregate Diesel 373.2941498 7747.295585 1.052431626 1052.431626 8263.421636 7747.295585 40123.45681 4.86 UBUS San Bernardino (SC)2024 SBUS Aggregate Aggregate Electricity 2.213199982 56.32019914 0 0 56.32019914 San Bernardino (SC)2024 SBUS Aggregate Aggregate Natural Gas 398.7600331 10010.49353 2.335353326 2335.353326 10010.49353 San Bernardino (SC)2024 UBUS Aggregate Aggregate Gasoline 54.72012078 5253.853518 0.406450205 406.450205 5253.853518 San Bernardino (SC)2024 UBUS Aggregate Aggregate Diesel 4.556959009 449.8374364 0.043468777 43.46877693 449.8374364 San Bernardino (SC)2024 UBUS Aggregate Aggregate Electricity 7.328344802 1111.359033 0 0 1111.359033 San Bernardino (SC)2024 UBUS Aggregate Aggregate Natural Gas 243.3602145 33308.40682 7.813502654 7813.502654 33308.40682 Source: EMFAC2021 (v1.0.2) Emissions Inventory Region Type: Sub-Area Region: San Bernardino (SC) Calendar Year: 2025 Season: Annual Vehicle Classification: EMFAC2007 Categories Units: miles/day for CVMT and EVMT, trips/day for Trips, kWh/day for Energy Consumption, tons/day for Emissions, 1000 gallons/day for Fuel Consumption Region endar Yehicle Catego Model Year Speed Fuel Population Total VMT Fuel_Consumption Fuel_Consumption Total Fuel VMT Total VMT Miles per Gallon Vehicle Class San Bernardino (SC)2025 HHDT Aggregate Aggregate Gasoline 3.869766832 177.2217014 0.044579975 44.57997511 322298.7048 177.2217014 1975659.248 6.13 HHDT San Bernardino (SC)2025 HHDT Aggregate Aggregate Diesel 14693.60242 1799109.244 296.221758 296221.758 1799109.244 San Bernardino (SC)2025 HHDT Aggregate Aggregate Electricity 109.5985203 11409.19414 0 0 11409.19414 San Bernardino (SC)2025 HHDT Aggregate Aggregate Natural Gas 2560.5176 164963.5875 26.0323668 26032.3668 164963.5875 San Bernardino (SC)2025 LDA Aggregate Aggregate Gasoline 457374.7047 20012363.19 659.2303928 659230.3928 671181.1368 20012363.19 21858504.21 32.57 LDA San Bernardino (SC)2025 LDA Aggregate Aggregate Diesel 986.5858319 34821.96021 0.803361461 803.3614609 34821.96021 San Bernardino (SC)2025 LDA Aggregate Aggregate Electricity 22921.29943 1119595.112 0 0 1119595.112 San Bernardino (SC)2025 LDA Aggregate Aggregate Plug-in Hybrid 13621.71468 691723.9558 11.14738256 11147.38256 691723.9558 San Bernardino (SC)2025 LDT1 Aggregate Aggregate Gasoline 39862.49619 1386010.237 55.44488475 55444.88475 55506.30461 1386010.237 1393998.156 25.11 LDT1 San Bernardino (SC)2025 LDT1 Aggregate Aggregate Diesel 9.62153332 138.8700264 0.005712258 5.712257886 138.8700264 San Bernardino (SC)2025 LDT1 Aggregate Aggregate Electricity 81.74409231 4029.090974 0 0 4029.090974 San Bernardino (SC)2025 LDT1 Aggregate Aggregate Plug-in Hybrid 75.22656194 3819.958249 0.055707597 55.70759743 3819.958249 San Bernardino (SC)2025 LDT2 Aggregate Aggregate Gasoline 197589.8024 8156000.659 328.0141754 328014.1754 330196.8511 8156000.659 8333682.032 25.24 LDT2 San Bernardino (SC)2025 LDT2 Aggregate Aggregate Diesel 559.2848358 24877.85405 0.732985994 732.9859937 24877.85405 San Bernardino (SC)2025 LDT2 Aggregate Aggregate Electricity 1637.444663 58171.59292 0 0 58171.59292 San Bernardino (SC)2025 LDT2 Aggregate Aggregate Plug-in Hybrid 1934.989022 94631.92591 1.449689627 1449.689627 94631.92591 San Bernardino (SC)2025 LHDT1 Aggregate Aggregate Gasoline 16963.11371 633447.7463 45.45107153 45451.07153 66469.9942 633447.7463 1077884.454 16.22 LHDT1 San Bernardino (SC)2025 LHDT1 Aggregate Aggregate Diesel 11403.02981 434286.2222 21.01892267 21018.92267 434286.2222 San Bernardino (SC)2025 LHDT1 Aggregate Aggregate Electricity 147.3648902 10150.48537 0 0 10150.48537 San Bernardino (SC)2025 LHDT2 Aggregate Aggregate Gasoline 2823.949841 99825.11713 8.149183621 8149.183621 18984.07565 99825.11713 289811.7154 15.27 LHDT2 San Bernardino (SC)2025 LHDT2 Aggregate Aggregate Diesel 4888.887446 187525.0486 10.83489203 10834.89203 187525.0486 San Bernardino (SC)2025 LHDT2 Aggregate Aggregate Electricity 37.58571717 2461.549606 0 0 2461.549606 San Bernardino (SC)2025 MCY Aggregate Aggregate Gasoline 20826.96994 123280.6812 2.925130919 2925.130919 2925.130919 123280.6812 123280.6812 42.15 MCY San Bernardino (SC)2025 MDV Aggregate Aggregate Gasoline 147056.3511 5833561.643 289.7409456 289740.9456 293881.6654 5833561.643 6036663.747 20.54 MDV San Bernardino (SC)2025 MDV Aggregate Aggregate Diesel 1906.902909 76374.47974 3.151065928 3151.065928 76374.47974 San Bernardino (SC)2025 MDV Aggregate Aggregate Electricity 1802.834782 63969.43971 0 0 63969.43971 San Bernardino (SC)2025 MDV Aggregate Aggregate Plug-in Hybrid 1256.812117 62758.18504 0.98965379 989.6537902 62758.18504 San Bernardino (SC)2025 MH Aggregate Aggregate Gasoline 3227.585522 28520.15334 5.836852659 5836.852659 6997.412696 28520.15334 40386.16204 5.77 MH San Bernardino (SC)2025 MH Aggregate Aggregate Diesel 1329.243498 11866.0087 1.160560036 1160.560036 11866.0087 San Bernardino (SC)2025 MHDT Aggregate Aggregate Gasoline 1427.423114 76828.767 14.58515666 14585.15666 88952.25214 76828.767 752323.1368 8.46 MHDT San Bernardino (SC)2025 MHDT Aggregate Aggregate Diesel 15347.54129 658670.5437 73.22420436 73224.20436 658670.5437 San Bernardino (SC)2025 MHDT Aggregate Aggregate Electricity 133.1585562 6928.399641 0 0 6928.399641 San Bernardino (SC)2025 MHDT Aggregate Aggregate Natural Gas 208.419151 9895.426472 1.142891124 1142.891124 9895.426472 San Bernardino (SC)2025 OBUS Aggregate Aggregate Gasoline 358.2884481 15030.55432 2.914537526 2914.537526 5188.582188 15030.55432 32494.86271 6.26 OBUS San Bernardino (SC)2025 OBUS Aggregate Aggregate Diesel 215.4704252 15216.87274 2.039111404 2039.111404 15216.87274 San Bernardino (SC)2025 OBUS Aggregate Aggregate Electricity 1.990200949 157.0570869 0 0 157.0570869 San Bernardino (SC)2025 OBUS Aggregate Aggregate Natural Gas 34.88313202 2090.378559 0.234933258 234.9332579 2090.378559 San Bernardino (SC)2025 SBUS Aggregate Aggregate Gasoline 300.4577721 14124.28621 1.57111818 1571.11818 4959.876607 14124.28621 31963.06277 6.44 SBUS San Bernardino (SC)2025 SBUS Aggregate Aggregate Diesel 363.8707141 7488.892183 1.014599014 1014.599014 7488.892183 San Bernardino (SC)2025 SBUS Aggregate Aggregate Electricity 4.690534617 132.2929048 0 0 132.2929048 San Bernardino (SC)2025 SBUS Aggregate Aggregate Natural Gas 411.4766102 10217.59148 2.374159413 2374.159413 10217.59148 San Bernardino (SC)2025 UBUS Aggregate Aggregate Gasoline 54.83056931 5264.458034 0.406547565 406.5475652 8275.384496 5264.458034 40204.44305 4.86 UBUS San Bernardino (SC)2025 UBUS Aggregate Aggregate Diesel 4.529432466 447.4667714 0.043317656 43.31765633 447.4667714 San Bernardino (SC)2025 UBUS Aggregate Aggregate Electricity 7.409987909 1124.502697 0 0 1124.502697 San Bernardino (SC)2025 UBUS Aggregate Aggregate Natural Gas 243.8212922 33368.01555 7.825519274 7825.519274 33368.01555 Oleander & Santa Ana Avenue Warehouse Energy Analysis 14581-02 EA Report This page intentionally left blank