Loading...
HomeMy WebLinkAbout6313-1Sheet Index SLOVER AVE 1 Cover Sheet 2 Irrigation Plan SIERRA PARK MEDIAN 3 Irrigation Schedule 4 Irrigation Details 5 Irrigation Details 6 Irrigation Details LANDSCAPE PLANS 7 Planting Plan 8 Planting Details 9 Specifications Fontana, Ca 10 Specifications I HAVE COMPLIED WITH THE CRITERIA OF THE MWELO ORIDINANCE AND APPLIED City Notes THEM FOR THE EFFICIENT USE OF WATER IN THE LANDSCAPE DESIGN PLAN. A minimum 3- inch layer of mulch shall be applied on all exposed soil surfaces of planting Recirculating water systems shall be used for water features. - No Certificate of Occupancy shall be issued until a City landscape inspector has verified areas except turf areas, creeping or rooting groundcovers, or direct seeding applications Pressure regulating devices are required if water pressure is below or exceeds the that all irrigation, grading, and planting have been completed in accordance with the where mulch is contraindicated. recommended pressure of the specified irrigation devices. approved plans and specifications of FCC Section 28-1 17 at time of final inspection. For soils less than six -percent (6%) organic matter in the top six (6) inches of soil, compost at Check valves or anti -drain valves are required on all sprinkler heads where low point An irrigation audit report shall be completed per FCC Section 28-106 at the time of final p 02/ 10/2023 a rate of a minimum of four (4) cubic yards per one -thousand (1,000) square be incorporated to depth inches into the feet of drainage could occur. inspection. A diagram the irrigation hydrozones be kept the irrigation With to landscape districts landscape, it be the SIGNATURE DATE permeable area shall a of six (6) At the time of final inspection, the permit applicant must provide the owner with a certificate of completion, certificate of installation, and an irrigation landscape and maintenance. soil. of plan showing shall with regard maintenance or public shall of the property controller for subsequent management purposes. responsibility of the developer to comply with FCC Section 28-118, Special Landscape schedule of A Certificate of Completion shall be filled out and certified by either the designer of the District Requirements. landscape plans, irrigation plans, or the licensed landscape contractor for the project. ABBREVIATIONS General Notes Field Inspection Requirements Vicinity Map AC ASPHALT CONCRETE PIP POURED IN PLACE IRRIGATION CJ COLD JOINT PROPERTY LINE R CENTERLINE or RAD RADIUS THE CONTRACTOR SHALL CONTACT THE CITY'S COMMUNITY DEVELOPMENT ENGINEERING DEPT. �ONC CONCRETE R RISER 1. FINAL LOCATION OF CONTROLLER TO BE DETERMINED IN THE FIELD WITH APPROVAL OF OWNER AND LANDSCAPE ARCHITECT. PUBLIC WORKS INSPECTION SECTION (909)350-6633 AT LEAST 48 HOURS TO INSPECT THE CONT CONTINUOUS RWD REDWOOD DIA DIAMETER RS ROUGH SAWN D.F. DOUGLAS FIR SL SCORELINE 2. REFER TO GENERAL IRRIGATION NOTES ON IRRIGATION PLAN. FOLLOWING:: 1. PRE -JOB CONFERENCE ONSITE. 2. COMPLETION OF FINISHED GRADE. 4LLE �t �....` .. EA EACH SHT SHEET EJ EXPANSION JOINT SPECS SPECIFICATIONS EQ EQUAL SQ SQUARE EXIST. EXISTING STD STANDARD PLANTING 3. LAYOUT OF WOOD OR CONCRETE HEADERS BUT PRIOR TO INSTALLATION. 4. IRRIGATION INSTALLATION AT HE FOLLOWING POINTS: \` ° \\ FRH FIRE HYDRANT STRUCT STRUCTURAL FS FINISH SURFACE S4S SURFACE FOUR SIDES FT FEET T TREAD FTG FOOTING THK THICK 1. ALL BOX TREES ARE TO BE SELECTED BY THE LANDSCAPE ARCHITECT. 2. CONTRACTOR IS TO SPOT ALL PLANT MATERIAL AND HAVE LANDSCAPE ARCHITECT APPROVE THE SPOTTING PRIOR TO THE EXCAVATION OF ANY PLANT PIT. ALLOW 48 HOURS LEAD TIME. ANY TREE, SHRUB, OR VINE THAT IS PLANTED WITHOUT A. POINT OF CONNECTION TO MAIN. B. BACKFLOW PREVENTION INSTALLATION PRIOR TO BACKFILL. C. TRENCHING (TO CHECK DEPTH). D. METER AND CONTROLLER PEDESTAL LOCATION. "1 � `� - o `~ \ GA GAUGE TOC TOP OF CONCRETE or CURE GALV GALVANIZE(D) TYP TYPICAL TOW TOP WALL APPROVAL OF THE LANDSCAPE ARCHITECT MAY BE MOVED AT THE CONTRACTOR'S EXPENSE. E. CONTROL VALVE INSTALLATION. F. MAINLINE INSTALLATION WITH PRESSURE TEST AT 150 PSI FOR 4 HOURS. GB GRADE OF HP HIGH POINT TOF TOP OF FOOTING 3. REMOVE STAKES FROM ALL ESPALIERS AND VINES AND ATTACH TO WALLS, POST, ETC. G. HEAD AND SWING JOINT INSTALLATION. `` MAX MAXIMUM UNO UNLESS NOTED OTHERWISE MIN MINIMUM VEH VEHICULAR 4. PRIOR TO PLANTING INSTALLATION, CONTRACTOR SHALL HAVE SOIL TESTED AND SEND RESULTS TO PUBLIC WORKS INSPECTOR. REFER TO SPECIFICATIONS FOR SOIL PREPARATION INFORMATION. H. HEAD COVERAGE. I. SLEEVING. y NIC NOT IN CONTRACT VERT VERTICAL NTS NOT TO SCALE WWM WOVEN WIRE MESH OC ON CENTER WI WROUGHT IRON 5. CONTRACTOR TO CONTACT LANDSCAPE ARCHITECT AND CITY INSPECTOR FOR FINAL INSPECTION WHEN INSTALLATION 5. WEED ABATEMENT. 6. ACCEPTANCE OF PLANT QUALITY AT DELIVERY SITE. AAR PA PLANTING AREA d NAIL PENNY SIZE IS COMPLETE, AND FOR A FINAL MAINTENANCE INSPECTION AT THE END OF THE MAINTENANCE PERIOD.AN MAINTENANCE NOTES 7. PLANT LAYOUT. 8. PLANT INSTALLATION. 9. FINAL INSPECTION.\ I AGREE TO COMPLY WITH THE 1. ALL CFD/LMD AREAS ARE TO BE MAINTAINED BY THE CONTRACTOR/DEVELOPER FOR A PERIOD OF 90 DAYS AND REQUEST REQUIREMENTS OF THE STATE MODEL A WALK-THRU EVERY 30 DAYS BY THE PUBLIC WORKS INSPECTION SECTION, ENGINEERING DIV. COM. DEV. DEPT. a -go WATER EFFICIENT LANDSCAPE ORDINANCE AND HAVE SUBMITTED A COMPLETE LANDSCAPE DOCUMENT PACKAGE. 2. ALL AREAS MUST BE MAINTAINED IN A HEALTHY, WEED FREE, AND VIGOROUS CONDITION PRIOR TO ACCEPTANCE BY THE CITY. 3. A MINIMUM OF ONE PUNCH LIST WILL BE DEVELOPED BY THE CITY TO NOTE DEFICIENCIES TO BE CORRECTED PRIOR TO LEGAL DESCRIPTION: PARCEL NO. 1 OF PARCEL MAP NO. 20250, IN THE CITY OF FONTANA, COUNTY OF SAN BERNADINO, STATE OF CALIFORNIA. Turnover Items 1 HAVE COMPLIED WITH THE CRITERIA OF THE ORIDINANCE AND APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE LANDSCAPE AND GRADING ACCEPTANCE. Hold Harmless & Indemnification Clause STATION POINTS LIMIT OF WORK: STA 10.00 - STA 23.00 l . PHOTO MYLAR "AS-BUILTS" 2. LAMINATED CONTROLLER CHARTS. DESIGN PLAN. CONTRACTOR AGREES THAT HE SHALL ASSUME SLOE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO 3. BACKFLOW CERTIFICATION. 4. QUICK COUPLER KEYS WITH SWIVEL HOSE ADAPTER 5. CONTROLLER KEYS (2) 12/08/2022 SIGNATURE DATE NORMAL WORKING HOURS, AND HOLD THE CITY AND THE LANDSCAPE ARCHITECT HARMLESS FROM ANY AND ALL LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER, CITY OR LANDSCAPE ARCHITECT. 6. VALVE BOX KEYS (2) 7. 1 YR. WRITTEN IRRIGATION GUARANTEE - INCLUDE COMPANY NAME, CONTACT PERSON, TELEPHONE NUMBER AND BUSINESS ADDRESS. BENCH MARK' HUNTER LANDSCAPEtXT 711 S. Fee Ana Street SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO ANDYEACARRIED OF DATE FORTHOIN A PROVAL DILIGENT SHOWN HEREON O �PNDSCgp ���� F9 �� PREPARED UNDER THE suREimsioN OF: CITY OF FONTANA, CALIFORNIA SIERRA PARK STREET IMPROVEMENTS DRAWN BY. COVer Sheet s AS Norm DESIGNED BY: DATE: Fa6nary 101h, 2023 SAN BERNARDINO COUNTY TBM PER FIELD BOOK 4015/848 Placentia, California 92870 ELEVATION = 1019.83', DATUM = 1929 Ph: 714.986.2400 our Two waea� ��� DAYS 813W CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH vavzozs wT a'� 3 9r RAILROAD SPIKE IN POWER POLE /71833, N.E. CORNER Fax: 714.986.2408 POPLAR AVE. & SANTA ANA AVE. EST. FROM SM B-38. = M = W mu ma +-400-sa-ago A PURE sow w W0°�01�0 � Aug STANDARDS IN EFFECT. F of cA F° Thomas Hayes DATE 02.1023 �+m APPa�Eo Bi APPROVED 0226'd'rczrav FOR DRAWING NO.: j 6313 10 REV. DESCRIPTION DATE ENGR. CITY DATE GIA LAM KIM CRY ENGINEER R C.E 62296 DATE