HomeMy WebLinkAbout6277-1DUKE - CITRUS AND SLOVER AVE
INSPECTION NOTES:
1. IT IS THE LANDSCAPE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE ENGINEERING DIVISION'S LANDSCAPE
INSPECTOR 48 HOURS PRIOR TO DESIRED INSPECTION OF AN ITEM AT (909) 350-6632
2. PRIOR TO RELEASE OF UTILITIES OR MAINTENANCE PERIOD COMMENCEMENT, THE FOLLOWING INSPECTIONS
ARE REQUIRED:
PRE -CONSTRUCTION INSPECTION
INSPECTION OF IRRIGATION SYSTEM IN OPEN TRENCH CONDITION (PRIOR TO BACKFILL). MAINLINE
PRESSURE TEST AT 150 PSI FOR A THREE (3) HOUR CONTINUOUS PERIOD.
IRRIGATION COVERAGE TESTS INCLUDE INITIAL AND FINAL TESTS.
FINISH GRADE PRIOR TO PLANTING
PLANT MATERIALS PRIOR TO PLANTING AND SOIL PREPARATION
PLANTING, INCLUDING STREET TREES. CONTACT THE PARKS AND PLANNING AND LANDSCAPE
DEVELOPMENT SECTION, ENGINEERING DIVISION, FOR SPECIES AND FINAL LOCATIONS.
COMPLIANCE WITH APPROVED PLANS.
FINAL INSPECTION.
3. THE OWNER'S REPRESENTATIVE AND LANDSCAPE CONTRACTOR SHALL BE PRESENT AT EACH INSPECTION.
4. A CERTIFICATE OF COMPLETION SHALL BE FILLED OUT AND CERTIFIED BY EITHER THE DESIGNER OF THE
LANDSCAPE PLANS, IRRIGATION PLANS OR THE LICENSED LANDSCAPE CONTRACTOR OF THE PROJECT.
5. COMPLY WITH SECTION 28-1 17 VERIFICATION OF LANDSCAPE INSTALLATION WITH THE CITY OF FONTANA
LANDSCAPE ORDINANCE #1734.
6. NO CERTIFICATE OF OCCUPANCY SHALL BE ISSUED UNTIL A CITY LANDSCAPE INSPECTOR HAS VERIFIED THAT
ALL IRRIGATION, GRADING AND PLANTING HAVE BEEN COMPLETED IN ACCORDANCE WITH THE APPROVED
PLANS AND SPECIFICATIONS OF SECTION 28-117 WITHIN THE CITY OF FONTANA LANDSCAPE ORDINANCE
# 1734.
7. AN IRRIGATION AUDIT REPORT SHALL BE COMPLETED PER SECTION 28-1 17 WITHIN THE CITY OF FONTANA
LANDSCAPE ORDINANCE #1734.
SOILS MANAGEMENT PLAN REQUIREMENTS:
CONTRACTOR SHALL OBTAIN SOILS TESTS COVERING ALL PLANTING AREAS AFTER COMPLETION OF FINISH GRADING
AND PRIOR TO START OF SOIL PREPARATION WORK. TESTS SHALL BE PERFORMED BY AN APPROVED CALIFORNIA
AGRONOMIC SOILS TESTING LABORATORY AND SHALL INCLUDE A FERTILITY AND SUITABILITY ANALYSIS WITH WRITTEN
RECOMMENDATIONS FOR SOIL PREPARATION AND PLANTING BACKFILL MIX. THE AMENDMENTS IN THESE
SPECIFICATIONS ARE THE MINIMUM REQUIREMENT AND ARE FOR BID PURPOSES. ALL SOILS CONDITIONING AND
AMENDMENTS SHALL BE PER THE FINAL SOIL REPORT RECOMMENDATIONS. THE MINIMUM AMENDMENT AND
FERTILIZER APPLICATION RATES SPECIFIED HEREIN ONLY WHEN THEY EXCEED THE SPECIFIED MINIMUMS.
THE PROJECT APPLICANT, OR HIS/HER DESIGNEE, SHALL COMPLY WITH THE FOLLOWING:
THE SOIL MANAGEMENT REPORT SHALL BE SUBMITTED TO THE CITY AS PART OF THE CERTIFICATE OF COMPLETION
PRIOR TO THE CERTIFICATE OF OCCUPANCY.
THE SOIL MANAGEMENT REPORT SHALL BE MADE AVAILABLE TO THE CITY LANDSCAPE INSPECTOR OR INSPECTOR
DESIGNATED BY THE CITY ENGINEER, AND TO THE LANDSCAPE CONTRACTOR PRIOR TO THE INSTALLATION OF ANY
PLANT MATERIAL.
THE PROJECT APPLICANT, OR HIS/HER DESIGNEE, SHALL HAVE AN INSPECTION BY A CITY LANDSCAPE INSPECTOR OR
INSPECTOR DESIGNATED BY THE CITY ENGINEER, VERIFYING IMPLEMENTATION OF SOIL MANAGEMENT REPORT
RECOMMENDATIONS.
AT THE TIME OF FINAL INSPECTION, THE PERMIT APPLICANT MUST PROVIDE THE OWNER OF THE PROPERTY WITH A
CERTIFICATE OF COMPLETION , CERTIFICATION OF INSTALLATION, IRRIGATION SCHEDULE OF LANDSCAPE AND
MAINTENANCE.
CITY REQUIRED STATEMENT:
I AGREE TO COMPLY WITH THE REQUIREMENTS OF THE WATER EFFICIENT LANDSCAPE ORDINANCE AND HAVE SUBMITTED
A COMPLETE LANDSCAPE DOCUMENT PACKAGE.
11/15/2022
THOMAS HAYES
Sheet Index
1
Cover Sheet
2
Irrigation Plan
3
Irrigation Schedules
4
Irrigation Details
5
Irrigation Details
6
Irrigation Details
7
Planting Plan
8
Planting Details
9
Specifications
10
Specifications
Contact Info
Owner/Applicant: Duke Realty
Name: Kyle Ficke
Address: Spectrum Center Drive, Suite 1600
Irvine, Ca 92618
Phone: 949-797-7042
Civil Engineer: Albert A. Webb Associates
Name: Byanka Velasco
Address: 3788 McCrary Street
Riverside, Ca 92506
Phone:951-320-6001
Landscape Architect: Hunter Landscape
Name: Tom Hayes
Address: 711S. Fee Ana Street
Placentia, Ca 92870
Phone: 714-986-2400
Water District: Fontana Water Company
Name: Joshua Swift
Address: 15966 Arrow Route
Fontana, Ca 92335
Phone:909-822-2201
Electrical: Southern California Edison
Phone:1-800-655-4555
ABBREVIATIONS I General Notes I Vicinity Map
AC
CJ
ASPHALT CONCRETE
COLD JOINT
PIP POURED IN PLACE
PROPERTY LINE
�ONC
CENTERLINE
CONCRETE
or RAD
R
RADIUS
RISER
CONT
DIA
CONTINUOUS
DIAMETER
RWD
RS
REDWOOD
ROUGH SAWN
D.F.
EA
DOUGLAS FIR
EACH
SL
SHT
SCORELINE
SHEET
EJ
EQ
EXPANSION JOINT
EQUAL
SPECS
SQ
SPECIFICATIONS
SQUARE
EXIST.
FRH
EXISTING
FIRE HYDRANT
STD
STRUCT
STANDARD
STRUCTURAL
FS
FT
FINISH SURFACE
FEET
S4S
T
SURFACE FOUR SIDES
TREAD
FTG
FOOTING
THK
THICK
GA
GALV
GAUGE
GALVANIZE(D)
TOC
TYP
TOP OF CONCRETE or CURB
TYPICAL
GB
HP
GRADE
HIGH POINT
TOW
TOF
TOP OF WALL
TOP OF FOOTING
MAX
MIN
MAXIMUM
MINIMUM
UNO
VEH
UNLESS NOTED OTHERWISE
VEHICULAR
NIC
NTS
NOT IN CONTRACT
NOT TO SCALE
VERT
WWM
VERTICAL
WOVEN WIRE MESH
OC
PA
ON CENTER
PLANTING AREA
WI
d
WROUGHT IRON
NAIL PENNY SIZE
IRRIGATION
1. FINAL LOCATION OF CONTROLLER TO BE DETERMINED IN THE FIELD WITH APPROVAL OF OWNER AND LANDSCAPE ARCHITECT
2. REFER TO GENERAL IRRIGATION NOTES ON IRRIGATION PLAN.
PLANTING
1. ALL BOX TREES ARE TO BE SELECTED BY THE LANDSCAPE ARCHITECT.
2. CONTRACTOR IS TO SPOT ALL PLANT MATERIAL AND HAVE LANDSCAPE ARCHITECT APPROVE THE SPOTTING PRIOR TO THE
EXCAVATION OF ANY PLANT PIT. ALLOW 48 HOURS LEAD TIME. ANY TREE, SHRUB, OR VINE THAT IS PLANTED WITHOUT
APPROVAL OF THE LANDSCAPE ARCHITECT MAY BE MOVED AT THE CONTRACTOR'S EXPENSE.
3. REMOVE STAKES FROM ALL ESPALIERS AND VINES AND ATTACH TO WALLS, POST, ETC.
4. PRIOR TO PLANTING INSTALLATION, CONTRACTOR SHALL HAVE SOIL TESTED AND SEND RESULTS TO PUBLIC WORKS
INSPECTOR. REFER TO SPECIFICATIONS FOR SOIL PREPARATION INFORMATION.
5. CONTRACTOR TO CONTACT LANDSCAPE ARCHITECT AND CITY INSPECTOR FOR FINAL INSPECTION WHEN INSTALLATION
IS COMPLETE, AND FOR A FINAL MAINTENANCE INSPECTION AT THE END OF THE MAINTENANCE PERIOD.
HUNTER LANDSCAPE
BENCH MARK: 711 S. Fee Ana Street
SAN BERNARDINO COUNTY TBM PER FIELD BOOK 4015/848 Placentia, California 92870
ELEVATION = 1019.83% DATUM = 1929 Ph: 714.986.2400
RAILROAD SPIKE IN POWER POLE /71833, N.E. CORNER Fax: 714.986.2408
POPLAR AVE. & SANTA AM AVE. EST. FROM BM B-38.
DIAL
�IIIITWO WORKING
L YOU DI YOU i
�� :0 00
A PUBLIC SERVICE BY
UNDERGROUND SERVICE ALERT
POTABLE WATER
TOTAL LANDSCAPE AREA:
15,662 SQ. FT.
CITY REQUIRED NOTES:
A MINIMUM 3" LAYER OF MULCH SHALL BE APPLIED ON ALL EXPOSED SOIL SURFACES OF PLANTING AREAS
EXCEPT TURF AREAS, CREEPING OR ROOTED GROUNDCOVERS, OR DIRECT SEEDING APPLICATIONS WHERE
MULCH IS IS CONTRAINDICATED.
FOR SOILS LESS THAN 6% ORGANIC MATTER IN THE TOP 6" OF SOIL, COMPOST AT A RATE OF A MINIMUM OF
FOUR CUBIC YARDS PER 1,000 SQUARE FEET OF PERMEABLE AREA SHALL BE INCORPORATED TO A DEPTH OF
SIX INCHES INTO THE SOIL.
RECIRCULATING WATER SYSTEMS SHALL BE USED FOR WATER FEATURES (DOES NOT APPLY)
PRESSURE REGULATING DEVICES ARE REQUIRED IF WATER PRESSURE IS BELOW OR EXCEEDS THE
RECOMMENDED PRESSURE OF THE SPECIFIED IRRIGATION DEVICES.
CHECK VALVES OR ANTI -DRAIN VALVES ARE REQUIRED ON ALL SPRINKLER HEADS WHERE LOW POINT
DRAINAGE COULD OCCUR.
A DIAGRAM OF THE IRRIGATION PLAN SHOWING HYDROZONES SHALL BE KEPT WITH THE IRRIGATION
CONTROLLER FOR SUBSEQUENT MANAGEMENT PURPOSES.
A CERTIFICATE OF COMPLETION SHALL BE FILLED OUT AND CERTIFIED BY EITHER THE DESIGNER OF THE
LANDSCAPE PLANS, IRRIGATION PLANS, OR THE LICENSED LANDSCAPE CONTRACTOR FOR THE PROJECT.
COMPLY WITH SECTION 28-117 VERIFICATION OF LANDSCAPE INSTALLATION WITHIN THE CITY OF FONTANA
LANDSCAPE ORDINANCE #1734.
WITH REGARDS TO LANDSCAPE MAINTENANCE DISTRICTS OR PUBLIC LANDSCAPE, IT SHALL BE THE
RESPONSIBILITY OF THE DEVELOPER TO COMPLY WITH FCC SECTION 28-118, SPECIAL LANDSCAPE DISTRICT
REQUIREMENTS.
SHOULD CONSTRUCTION OF THE REQUIRED Q PNos�p
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON `? DRAWN BY:
AND CARRIED FORTH IN A DILIGENT MANNER, THE PREPARED UNDER THE SUPERVISION OR
CITY ENGINEER MAY REQUIRE REVISIONS TO THE 1/31/2023 DESIGNED Br:
PLANS TO BRING THEM INTO CONFORMANCE WITH sT'F of°caue�R�,e
STANDARDS IN EFFECT. Th- Hq.a DATE: 11.15.22
10 Freeway
SITE
slaver Ave
a a Q
2 � a
U �
U
CITY OF FONTANA, CALIFORNIA
Citrus and Slover Ave Street Improvements
Cover Sheet DATE:
APPROVED Nw ffdw Ift. 2022
iPPROVED BY. 01 `16t2023 rgaray FOR DRAWING NO.:
GIA LAM KIM CRY ENGINEER RCE 62296 DATE 6277 F , 0