HomeMy WebLinkAbout6277-4NOTE:
DO NOT INSTALL 120 VOLTAGE OR HIGHER WIRE
IN THE SAME TRENCH AS THE IRRIGATION
CONTROL WRING
ROFESS/Okd A ROVED BT CITY OF FONTANA
PaSG iS.i6ay >As
N..51152 CITY ENGINEER DATE PIPING AND WIRING
RICARDO SANDOVAL
EXP. 9t3NL5
REVIEWED BY: Timatnr RnNrvri+
F 6{ r:,LiF44'�YP DATE OF LAST REVISION: 1 28-00 5 STD. PLAN NO. 015 1 SHT ') Of
Revised 3-30-2022 KBS
10" VALVE BOX MARKED W/ 2" QUICK COUPLER VALVE
LETTERS READING Q.C.
W/ LOCKING BOLT LID
SEE STD 5W7 FOR BOX INSTALLATION DETAILS 12• MIN FROM HARCSCAPE MATERIALS
FINISH GRADE -
V n
6" Mhti PEA RAVE
2 x §RWD OR BRICK
BRASS STREET ELL T P
PASS NIPPLE S" MIN
PVC S C 40 TEE OR ELL
LATERAL LINE SIZE TO BE NOTED ON PLAN
24" MIN. #4 REBAR, ATTACH
WA2) STAINLESS STEEL BANDS
NOTE:
USE TEFLON TAPE ON ALL 7HREADED FITTINGS
sss! FONTANA
o CITY OF A 0
4 P ROV D BY: ,
ko E
O 1
0e�\P4D9 $1An�!
3-15 2022
CITY ENGI EER DATE
( vw.stTs2 QUICK COUPLER
RICARDO SANDOVAL
+ EXP e "M5 +
REVIEWED BY:. KS
zYaU
il}t Cf CAii144'�\p STD. PLAN NO. 5021 SET 1 OF 1
Revisetl 3-39-2022 KBS
FINISHED GRADE
6" MIN FROM HARDSCAPES
NON PRESSURE LATERAL LINE
'TERAL LINE
?r PRESSURE SUPPLY LINE
2 CONTROLL WIRES
-CLEAN BACKFILL
I� I
6"MIN
FINE GRANULAR MATERIAL WILL BE PLACED ON ALL LINES, NO
LARGER THAN 1/2" INCH IN SIZE. THIS WILL BE PERMITTED IN THE
INITIAL BACKFILL MEASURED 6'" FROM THE TOP OF PIPE. THE REMAINDER
OF TRENCH CAN BE FILL WITH ROCK SCREENED 2" MINUS.
ALL BACK FILL IS TO BE SATURATED AND COMPACTED TO 90%"
INSTALL ALL PVC PIPE WITH LABEL UP.
SNAKE ALL PIPE IN TRENCH.
BUNDLE AND TAPE ALL CONTROL WIRES AT 10' O.C. TO PRESSURE
SUPPLY LINE AND PROVIDE A SERVICE LOOP AT ALL 90 DEGREE
CHANGES IN DIRECTION,
PRESSURE MAIN 2" AND LARGER SHALL BE P.V.C. CLASS 315
SMALLER THAN 2" SHALL BE P.V.C- SCHEDULE 40.
CONTRACTOR SHALL PROVIDE SLEEVES OR CONDUIT LINES WHEN
MAINLINE INSTALLATION IS UNDER ASPHALT OR CONCRETE,
CONTRACTOR SHALL PROVIDE 24" INCHES OF COVER OVER PIPE
SERVING A DRINKING FOUNTAIN OR PRESSURE MAINLINE
3" AND LARGER,
SQE`4R o4E sp1 F AP Ov BY: //{ CITY OF FONTANA
e No.51152 p- CITY ENGINEER DATE TRENCHING DETAIL
RICARDO SANDOVAL
* EXP. 5.J0t05 ...
REVIEWED BY: T.mnthv Ra uSL...
sT'�Tf Of Ai14p DATE OF LAST REVISION! 1-28-00 STD. PLAN NO. 5015 SHE 1 OF
zExLzaAErmoExVw L 1419a
w o xalxzE s sxEEz aozx s
woszesoE�awo
E4ou} um s cxEO wx x eLo
Nuxex vaLVExsxe sxOxsoaT Eoxxoxx
INSTALLATION DETAIL
'VISH GRADE
1!
I (
� � I I I I I �.7 I li 11 § i —�' � I ;' � (I, • ,. i �„ 1_
BRA —IS ��� '.'� PVC MALE ADAPTOR
GA.E VA: VE-- _ -
t
wAINUNe
2" x 4" FIND BLOCK
1 CU, FT. PEA GRAVEL
x' _ ypy cr l/ s� 3-15-2022
No.5t152r >o=. CITY ENGINEER DATE GATE VALVE
RICARDO SANDOVAL
Owl
tN` f REVIEWED 8Y: KS
'..
'..,. STET—F� 1
Revised 3-31SO22 KBS
SLIP BASE SOCKET OVER
END OF WIRES
STRIP WIRES APPROX. 5/8"
FROM ENDS
STEP i
PUT CRIMP SLEEVE OVER
J WIRE ENDS —CRIMP SLEEVE
k
fI APPLY SEALER TO INSIDE
-. I, OF SEALING PLUG
FILL BASE SOCKET WITH SEALER
STEP 3
z PUSH SEALING PLUG INTO
BASE SOCKET UNTIL IT LOCKS
STEP 4
--
PUSH WIRES TO END OF BASE
--- -- SOCKET TO ASSURE COMPLETE
SEALING OF CONNECTION
RAINBIRD SNAP—TITE WIRE
CONNECTOR "OR EQUAL`
QE�4AeFessrak�r ROVED BY: i CITY OF FONTANA
Ad`day'`rs �
4p�,ae
No, 5t152 '� CITY ENGINEER DATE WIRE CONNECTOR
41CARDO SANDOVAL
EXP_W305 +
REVIEWED BY: rn,pLy Rncrxvit
)`OFclvn
Cpi149RaY4 DATE OF LAST REVISION' t —L6—QQ STD. PLAN NO. SJt3
CLEAN BACK ELL SATURATE AND COMPACT TO 90%
*'SABACKFILL
SCAPING
NATIVE 2" MINUS
NON PRESSURE LATERAL ONE W/SLEEVE
PRESSURE SUPPLY LINE W/SLEEVE
CONTROL WIRE SLEEVE
ND BACK FILL
2" MIN—
M�
N4IES;
INSTALL CONTROL WIRE SLEEVE ADJACENT TO THE PRESSURE SUPPLY LINE, SIZE PER
SPEC -
ALL SLEEVES TO BE SCH, 40 PVC AND TO BE 2X THE DIAME EP, OF THE LINE TO BE
SLEEVED.
' INCREASE THIS DISTANCE TO 36' WHEN SLEEVING UNDER ROADWAYS AND COMMERCIAL
TRAFFIC WAYS WHEN INSTRUCTED BY INSPECTOR.
SLEEVES SHALL BE EXTENDED BEYOND HAROSCAPE TO POINTS AS REOUETFO BY
INSPECTOR
IF SLEEVES ARE TO BE USED AT A LATER DATE, CONTRACTOR SHALL TAPE ENDS AND
PROVIDE A VERTICAL MARK AT ENDS OF SLEEVING VISIBLE AT GROUND LEVEL.
�0 4s01LSE'or APP ovED BY: CITY OF FONTANA
s.,4 ATp9 S,{,yS3 Fyn 1
No.3ii52 > CITY ENGINEER DATE ` SLEEVING DETAIL
RICARDO SANDOVAL
E%P. &'30i05
REVIEWED BY: Cmtny Rnc4nrtt
DATE OF LAST REVISION: 1-28-00
STD. PLAN ND. 5018 s SHT 1 OF ')
c No. 51152 A vCITY ENGINEER DATE TYP. BRASS REMOTE
RICnaDo saNDovaL CONTROL VALVE DETAIL
REVIEWED BY:
KS
4rp OF CAl\494� DATE OF LAST REVISION: 2-8-22 STD. PLAN NO, 5011 SHT 1 OF 1
/WATER PROOF CONNECTION
INSTALL A 10" ROUND
PLASTIC BOX WITH
LOCKING LID SEE STD 504? :....
FOR BOX INSTALLATION Z
DETAILS
SPLICE BLOCK MIN. 24 ABOVE GRADE
_FINISH GRADE
WiR€
` 2' x 4' RWD BLOCK
1 7 CU. F', PEA GRAVEL
NOTE:
REMOTE CONTROL BOX MAY BE USED IN LIEU OF SPLICE 80X.
SEE STD 5047 FOR BOX INSTALLATION DETAILS
��v 4flsessl PROVE Y CITY OF FONTANA
,
r 13 15 2022 SPLICE BOX
No. 5t152 AI CITY ENGINEER DATE
Rlcaeoo saNDovaL ASSEMBLY
REVIEWED BY: KS
'fl'4T crm .v40vR - -.
STD. PLAN N0. 5717 ; SET 1 OF 1
r�
DISTRIBUTION TUBING
AND OUR CAP To MATCH
-
EMITTER MODEL AND MFG,
SHRUB
a
MULCH
FINISH GRADE
ROOTBALL
C
-EMITTER, SEE LEGEND FOR
MFG. MODEL AND OTY.
SCHEDULE
DRIP TUBING, SEE LEGEND
FOR MFG MODEL AND SIZE
DRIP EMITTER
PVC SCH 40 ELL
PVC SCH 80 NIPPLE (TYPICAL,
LENGTH AS REQUIRED)
4 SPARE 30—INCH LINEAR
LENGTH OF WIRES, COILED.
WATER PROOF CONNECTOR: }
SPEARS DRI SPLICE DS400
(1 OF 2)
CARSON JUMBO VALVE BOX
WITH COVER (PURPLE).
DRIP TO BE 24X24 JUMBO
ID TAG: CARSON VIC SERIES
TOP OF MULCH
FINISH GRADE
ELECTRIC CONTROL VALVE WITH 1 3" now. i
PRESSURE REGULATOR I
RAINBIRD: EFB—CP—PRS—D
I I
'RECLAIMED WATER ID TAG
PVC LATERAL I
PVC SCH 40 MALE ADAPTER
PVC SCH 80 NIPPLE, CLOSE (1 OF 3)
PVC SCH 80 UNION FOR SERVICING ASSEMBLY
QUICK CHECK PRESSURE REGULATING
BASKET FILETR: SEE LEGEND FOR SPEC.
BRASS NIBCO BALL VALVE
OR APPROVED EQUAL
PVC MAINLINE
3—INCH MINIMUM DEPTH OF
3/4—INCH WASHED GRAVEL
BRICK (1 OF 4)
PVC SCH 80 NIPPLE (2—INCH
LENGTH, HIDDEN) AND
PVC SCH 40 ELL
PVC SCH 40 TEE OR ELL
' RECLAIMED WATER ID TAG TO BE 3"X4" CHRISTY'S ID TAG
(PURPLE) ATTACHED W/ NYLON TIE. LABEL TO READ "RECLAIMED
WATER — DO NOT DRINK" IN ENGLISH & SPANISH.
NOTE: INSTALL CONTROL VALVES MINIMUM OF 3 FT- APART
IN SHRUB AREAS UNLESS OTHERWISE NOTED.
o449FessroNt APPROV-BY.`` / CITY OF FONTANA
tioe�\aR99 Sapppy(F•i z•w`>,'r...%>:.`: 3-15-22
No. 5tt52' CITY ENGINEER DATE AUTOMATIC DRIP VALVE
RICARDO SANDOVAL
* +
REVIEWED BY: KS
fl'tTf OF CA0�4aP DATE OF LAST REVISION: 2-8-22 STD. PLAN NO. 5038 SHT 1 OF 1
SHOULD CONSTRUCTION OF THE REQUIRED CITY OF FONTANA, CALIFORNIA
O VPNDSCgp
IMPROVEMENTS NOT COMMENCE WITHIN TWO ���� F9 Citrus and Slover Ave Street Improvements
HUNTER LANDSCAPE YEARS OF THE DATE OF APPROVAL SHOWN HEREON w Pm DRAWN BY: SCALE:
BENCH MARK: 711 S. Fee Ana Street ~~ ^^^^^^^^^� AND CARRIED FORTH IN A DILIGENT MANNER, THE re PREPARED UNDER THE SUPERVISION OR DESIGNED BY: Irrl atlOn Details DATE:
SAN BERNARDINO COUNTY TBM PER FIELD BOOK 4015/848 TILL Placentia, California 92870 01LL � CITY ENGINEER MAY REQUIRE REVISIONS TO THE 1/31/2023 *
ELEVATION = 1019.83% DATUM = 1929�� BATS off= wT D °3 Al Nw ffbw Ift. 2022
RAILROAD SPIKE IN POWER POLE #71833, N.E. CORNER Ph: 714.986.2400 T11u ao IOU Bls PLANS TO BRING THEM INTO CONFORMANCE WITH 'F �� CHECKED BY: APPROVED BY, DRAWING NO.:
POPLAR AVE. & SANTA ANA AVE. EST. FROM SM B-38. Fax: 714.986.2408 TOL 1� ANEW soWl� w +moo-m-seoo STANDARDS IN EFFECT. °F CALIF ThomW IL�ye DATE ,,.,sz2 01 `16,'2023 rgaray FOR 4
MERT REV. DESCRIPTION DATE ENGR. CITY DATE GIA LAM KIM CITY ENGINEER RICE 62296 1ATE 6277 10