Water System Hydraulic Analysis
Date: July 20, 2021
For: City of Fontana By: Katie O'Connor, P.E.
Hunsaker & Associates Irvine, Inc.
Project:Begonia Village at Route 66
Hunsaker & Associates Irvine, Inc. (H&A) is pleased to submit the Water System
Hydraulic Analysis for the Begonia at Route 66 project. This analysis has been prepared
to describe the proposed water system for the aforementioned multi-family development
project in the City of Fontana. The project lies within the jurisdiction of the City of
Fontana and Fontana Water Company and their standards have been used for this
report. The Fontana Water Company consists of water facilities managed and
maintained by San Gabriel Valley Water Company. Hydraulic models were prepared
using Haestad Methods software to model various flows during steady state conditions.
THE PROPOSED WATER SYSTEM FOR THE BEGONIA AT ROUTE 66 PROJECT
MEETS THE DESIGN STANDARDS SPECIFIED BY THE FONTANA WATER
COMPANY AND THE CITY OF FONTANA. This evaluation is based on existing and
known conditions and should be re-evaluated if these conditions change or new
information becomes available. Any interpretation of the information presented in this
report should be referred to H&A to ensure the integrity of the results.
Project Location
The Begonia at Route 66 project is located adjacent to Foothill Blvd. in the City of
Fontana. The general project location is shown on exhibit entitled, “Vicinity Map.”
Summary of Findings
1.The development will include 423 multi-family dwelling units on a 10.64 acre site
in the City of Fontana at the corner of Foothill Blvd. and Tokay Avenue.
2.Water supply is provided by the Fontan Water Company through an existing
San Gabriel Valley Water Company water system. The Static Hydraulic grade
was assumed to be 1509 feet based on a fire hydrant flow test on Tokay
Avenue, included in the Appendix for Reference.
3.The proposed onsite water system consists of 8 and 10-inch diameter water
mains. The proposed water system includes two connections to San Gabriel
Valley Water Company water mains surrounding the project. The water system
schematic is shown on the attached “Water Model Exhibit– Figure 1.”
H&A G-4 4/14/98
Water System Hydraulic Analysis, con’t
Begonia Village at Route 66, Fontana
July 20, 2021
Page 2
4.The Begonia Village at Route 66 consists of a private on-site water system that
connects to the existing San Gabriel water mains in two locations. The on-site
water demands were calculated using fixture units for the proposed residential
units.
5.H&A estimated the flow constant “K” using Affinity Laws to determine the HGL of
the water supply at maximum demands and maximum demands plus 4000 gpm
fire flow events. The flow constant for this water system is K = Q / Hf^0.54 where
Hf is the difference (in feet) of the measured static and residual pressure at the
test flow. The “K” value for the water system is estimated to be 500 based on the
fire flow test included in the Appendix.
6.In order to calculate the pipe sizes, velocities and available pressure of the
proposed water system for Begonia Village a Route 66, we have prepared a
hydraulic model using WaterCad v7.0 by Haestad Methods. The summary of
outputs from the model runs are included in the Appendix of this report.
7.The proposed water system provides pressures greater than 80 psi for all nodes
during maximum demands calculated using fixture units. The minimum in-track
maximum demand pressure experienced was 96 psi with an estimated HGL of
1508 feet at the modeled fire flow test hydrant on Tokay Avenue. The following
table summarizes the model run:
Table 1 – Summary of Maximum Demand Model Run
Total Flow
(gpm)
Minimum in-tract
Residual Pressure
(node)(psi)
491 J-4 96
8.Fire flow requirement were taken for Begonia Village at Route 66 is 4000 gpm
for 4 hours with a minimum pressure requirement of 2 psi. This fire flow was
distributed between 3 proposed fire hydrants.
9.The proposed water system provides pressures greater than 20 psi during
maximum demands plus 4000 gpm fire flow events as required by the Fire
Department. The minimum residual pressure experience for the worst-case
4000 gpm fire flow event (split over three proposed fire hydrants) was 39 psi
with an estimated HGL of 1451 feet at the modeled fire flow test hydrant on
Tokay Avenue. The following table summarizes the MDD plus Fire Flow events:
Table 3 - Summary of Fire Flow Model Runs
Fire Flow
Node
Node
Elevation
FU+FF
at Node Node HGL Residual
Pressure
Max Fixture Unit Demand + 4000gpm Fire Flow
J-10 1304 ft 1333 gpm 1394 ft 39 psi
J-13 13040 ft 1333 gpm 1399 ft 43 psi
J-17 1303 ft 1333 gpm 1414 ft 48 psi
H&A G-4 4/14/98
Water System Hydraulic Analysis, con’t
Begonia Village at Route 66, Fontana
July 20, 2021
Page 3
All domestic water meters will require individual pressure reduction devices to reduce
the pressure to a maximum of 80 psi for each dwelling unit and commercial building
within the project site
We sincerely trust these calculations will provide sufficient evidence that the proposed
water system is adequate for the proposed Begonia Village at Route 66 project. Please
contact me at (949) 458-5437 if you have any questions.
KO:klo:
Enclosures
xc: Ben Etemadi, H&A
Tin Huynh, H&A
W.O. 4423-8
(F:\1187\Engineering\SY_WS Study\Water\WT_Report.doc)
Map No. 127 1 in = 150 ft ¯TOKAY AVE
I R V I N E , I N C .
PLANNING
PH: (949)583-1010
SURVEYING
FX: (949)583-0759Irvine, CA 92618Three Hughes
ENGINEERING
BEGONIA VILLAGE
Scenario: FIXTURE UNIT Demand (FU)
FlexTable: Junction Table
Label Elevation
(ft)
Demand
(gpm)
Hydraulic
Grade
(ft)
Pressure
(psi)
J-1 1306 0 1508 87
J-2 1302 0 1508 89
J-3 1306 0 1528 96
J-4 1306 31 1528 96
J-5 1306 16 1528 96
J-6 1305 16 1528 96
J-7 1306 31 1528 96
J-8 1305 0 1528 97
J-9 1305 47 1528 97
J-10 1304 0 1528 97
J-11 1302 175 1528 98
J-12 1300 175 1528 99
J-13 1300 0 1528 99
J-14 1300 0 1528 99
J-15 1295 0 1505 91
J-16 1297 0 1505 90
J-17 1303 0 1507 88
7/19/2021
Bentley Systems, Inc. Haestad Methods Solution Center
27 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
Bentley WaterCAD V8i
[08.11.00.30]
1
BEGONIA VILLAGE
Scenario: FIXTURE UNIT Demand (FU)
FlexTable: Pipe Table
Label Diam.
(in)
Length
(ft)
Start
Node
Stop
Node
Hazen-
Williams
C
Flow
(gpm)
Velocity
(ft/s)
Headloss
(Friction)
(ft)
P-1 8 142 J-1 J-2 120 0 0.00 0.00
P-2 8 33 J-2 PBV-1 130 0 0.00 0.00
P-3 10 11 PBV-1 J-3 130 0 0.00 0.00
P-4 10 110 J-3 J-4 130 0 0.00 0.00
P-5 10 37 J-4 J-5 130 31 0.13 0.00
P-6 10 124 J-5 J-6 130 47 0.19 0.00
P-7 10 43 J-6 J-7 130 63 0.26 0.00
P-8 10 109 J-7 J-8 130 94 0.38 0.01
P-9 8 97 J-8 J-9 130 47 0.30 0.01
P-10 10 43 J-8 J-10 130 141 0.58 0.01
P-11 10 159 J-10 J-11 130 141 0.58 0.03
P-12 10 207 J-11 J-12 130 316 1.29 0.15
P-13 10 74 J-12 J-13 130 491 2.01 0.12
P-14 10 13 J-13 J-14 130 491 2.01 0.02
P-15 10 22 J-14 PBV-2 130 491 2.01 0.04
P-16 10 43 J-15 PBV-2 130 491 2.01 0.07
P-17 17 436 J-15 J-16 120 491 0.69 0.06
P-18 8 335 J-16 J-17 120 491 3.13 1.90
P-19 8 79 J-17 J-1 120 491 3.13 0.45
P-20 8 32 J-1 R-1 120 491 3.13 0.18
7/19/2021
Bentley Systems, Inc. Haestad Methods Solution Center
27 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
Bentley WaterCAD V8i
[08.11.00.30]
2
BEGONIA VILLAGE
Scenario: FIXTURE UNIT Demand (FU)
FlexTable: PBV Table
Label Elevation
(ft)
Valve
Diameter
(in)
Pressure
Setting
(Initial)
(ft)
Flow
(gpm)
Headloss
(ft)
PBV-1 1,302.00 10 10 0 23.12
PBV-2 1,299.00 10 10 491 23.12
7/19/2021
Bentley Systems, Inc. Haestad Methods Solution Center
27 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
Bentley WaterCAD V8i
[08.11.00.30]
3
BEGONIA VILLAGE
Scenario: FIXTURE UNIT Demand (FU)
FlexTable: Reservoir Table
Label Elevation
(ft)
Flow
(Out net)
(gpm)
Hydraulic Grade
(ft)
R-1 1508 491 1508
7/19/2021
Bentley Systems, Inc. Haestad Methods Solution Center
27 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
Bentley WaterCAD V8i
[08.11.00.30]
4
BEGONIA VILLAGE
Scenario: FIXTURE UNIT + FIRE FLOW Demand (FU+FF)
FlexTable: Junction Table
Label Elevation
(ft)
Demand
(gpm)
Hydraulic
Grade
(ft)
Pressure
(psi)
J-1 1306 0 1440 58
J-2 1302 0 1440 60
J-3 1306 0 1394 38
J-4 1306 31 1394 38
J-5 1306 16 1394 38
J-6 1305 16 1394 38
J-7 1306 31 1394 38
J-8 1305 0 1394 38
J-9 1305 47 1394 38
J-10 1304 1333 1394 39
J-11 1302 175 1395 40
J-12 1300 175 1398 42
J-13 1300 1333 1399 43
J-14 1300 0 1400 43
J-15 1295 0 1357 27
J-16 1297 0 1359 27
J-17 1303 1333 1414 48
7/19/2021
Bentley Systems, Inc. Haestad Methods Solution Center
27 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
Bentley WaterCAD V8i
[08.11.00.30]
5
BEGONIA VILLAGE
Scenario: FIXTURE UNIT + FIRE FLOW Demand (FU+FF)
FlexTable: Pipe Table
Label Diam.
(in)
Length
(ft)
Start
Node
Stop
Node
Hazen-
Williams
C
Flow
(gpm)
Velocity
(ft/s)
Headloss
(Friction)
(ft)
P-1 8 142 J-1 J-2 120 121 0.77 0.06
P-2 8 33 J-2 PBV-1 130 121 0.77 0.01
P-3 10 11 PBV-1 J-3 130 121 0.49 0.00
P-4 10 110 J-3 J-4 130 121 0.49 0.01
P-5 10 37 J-4 J-5 130 90 0.37 0.00
P-6 10 124 J-5 J-6 130 74 0.30 0.01
P-7 10 43 J-6 J-7 130 58 0.24 0.00
P-8 10 109 J-7 J-8 130 27 0.11 0.00
P-9 8 97 J-8 J-9 130 47 0.30 0.01
P-10 10 43 J-8 J-10 130 20 0.08 0.00
P-11 10 159 J-10 J-11 130 1353 5.53 1.71
P-12 10 207 J-11 J-12 130 1528 6.24 2.80
P-13 10 74 J-12 J-13 130 1703 6.96 1.22
P-14 10 13 J-13 J-14 130 3037 12.40 0.63
P-15 10 22 J-14 PBV-2 130 3037 12.40 1.04
P-16 10 43 J-15 PBV-2 130 3037 12.40 2.05
P-17 17 436 J-15 J-16 120 3037 4.29 1.84
P-18 8 335 J-16 J-17 120 3037 19.38 55.49
P-19 8 79 J-17 J-1 120 4370 27.89 25.80
P-20 8 32 J-1 R-1 120 4491 28.66 11.05
7/19/2021
Bentley Systems, Inc. Haestad Methods Solution Center
27 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
Bentley WaterCAD V8i
[08.11.00.30]
6
BEGONIA VILLAGE
Scenario: FIXTURE UNIT + FIRE FLOW Demand (FU+FF)
FlexTable: PBV Table
Label Elevation
(ft)
Valve
Diameter
(in)
Pressure
Setting
(Initial)
(ft)
Flow
(gpm)
Headloss
(ft)
PBV-1 1302 10 20 121 46
PBV-2 1299 10 20 3037 46
7/19/2021
Bentley Systems, Inc. Haestad Methods Solution Center
27 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
Bentley WaterCAD V8i
[08.11.00.30]
7
BEGONIA VILLAGE
Scenario: FIXTURE UNIT + FIRE FLOW Demand (FU+FF)
FlexTable: Reservoir Table
Label Elevation
(ft)
Flow
(Out net)
(gpm)
Hydraulic Grade
(ft)
R-1 1451 4491 1451
7/19/2021
Bentley Systems, Inc. Haestad Methods Solution Center
27 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
Bentley WaterCAD V8i
[08.11.00.30]
8
WATER DEMAND CALCULATIONS
BIG HOUSE
(12-PLEX)
WRAP
BUILDING
TOTAL
FIXTURE
UNITS
DEMAND
(GPM)BUILDING TYPE
FIXTURE
UNITS
J 1 0 0 0 0 BIG HOUSE (12-PLEX)114
J 2 0 0 0 0 WRAP BUILDING 2121
J 3 0 0 0 0
J 4 2 0 228 31
J 5 1 0 114 16
J 6 1 0 114 16
J 7 2 0 228 31
J 8 0 0 0 0
J 9 3 0 342 47
J 10 0 0 0 0
J 11 2 0.5 1288.5 175
J 12 2 0.5 1288.5 175
J 13 0 0 0 0
J 14 0 0 0 0
J 15 0 0 0 0
J 16 0 0 0 0
J 17 0 0 0 0
13 1 3603 490
NODE
TOTALS
Description
Static
Max Flow (FU)
FU+ 4000 FF
*
**
Orifice Dia 4.0 in.
Static Pressure 88 psi 203 feet
Residual Pressure 78 psi 180 feet
Pitot Reading 40 psi
Observed Flow 2,718 gpm
Test Elevation 1,306 feet
Affinity Equations:
•
•
•
•
QF
K
Affinity Constant: (Using Flow Test Values)
K =500
HUNSAKER
& ASSOCIATES
I R V I N E , I N C.
HGL Calculation Based on Hydrant Test on Tokay Ave.
Desired Flow QF
(gpm)
Dynamic Loss HF
(feet)*
Available HGLF
(feet)**Test Run
0 0.00 1,509 1
490 0.96 1,508 2
HR^0.54 QR is Test Flow
4,490 58.03 1,451 3
HF is Static minus Residual (in feet) at Desired Flow
HGLF = Test Elevation + Static Pressure - HF
QF is Desired Flow
HR is Static minus Residual (in feet) at Test Flow
HF =()^1.85
Hydrant Test Data:
K =QR K is Affinity Constant
F:\1187\Engineering\SY_WS Study\Water\
Hydrant Test HGL.xls
Tokay Ave
Page 1 of 1
ENGINEERING DEPARTMENT
15966 ARROW ROUTE FONTANA, CALIFORNIA 92335 (909) 201-7375 Fax (909) 201-7377
January 14, 2021
Mr. Rod Fermin
Begonia Real Estate and Development, Inc
300 Spectrum Center Dr., Suite 400
Irvine, CA 92618
Subject: 15926 Foothill Blvd.
Fontana, CA
Dear Mr. Fermin:
In response to your request, we are furnishing herewith fire flow information based
upon the results of a flow test conducted near the subject location. The results are as
follows:
Static Water Pressure 88 PSI
Pitot Reading 40 PSI
Observed Flow 2718 GPM
Residual Water Pressure 78 PSI
Please be reminded that the flow information listed above indicates the capability of
the water system at the time the test was made. Since the capacity of the water system may
vary as a result of many factors, including changes in demand placed on the water system by
our customers, we recommend that you give adequate consideration to these variations
when performing your analysis.
If you need any additional information or have questions, please call me on my direct
line (909) 201-7347 or via e-mail at lzzhou@sgvwater.com.
Very truly yours,
Liuzong Zhou, P.E.
Design Manager
SEE DETAIL - A IN NEXT PAGE
SEE DETAIL - AIN NEXT PAGE
SEE DETAIL - B IN NEXT PAGE
SEE DETAIL - C IN NEXT PAGE
¤¤Íá
ááá Íá
áááÍááááÍááááÍáááá
Íááá
á
Íáááá Íá
ááá
¤¤¤ÍááááÍáááá¤Íáááá
Íá
áááÍá
ááá
ÍááááÍááááÍááááÍááá
á ¤Íá
ááá
¤Íáááᤤ¤¤¤¤¤¤
Íáááá
Íá
ááá
Íááá
á
ò¤
b
bbbbbbbb
bb"U)"U)"U)"U)"U)"U)"U)"U)"U)"U)
"U)"U)ÆÇ ")")")")")")")")
")
")
")
")")")")")")")")
")
")
")")")")")")")")")")")")
")
")
")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")
")")")")")")")")")")")
")")")")")")")")")")")")")")")")
")
")
")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")
")")")")")")")")")
")
")")")")")
")
")
")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")")!'!'!'!'!'!'!'!'!'!'!'!'
!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'
!'
!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'
!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'
!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'
!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'
!'!'
!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'!'
\!'!'!'!'!'!'!'
!'!'!(!(!(!(!(!(!(!(!(!(
!(
!(
!(!(!(!(!(!(!(!(!(!(!(!(!(!(!(!(!(!(!(!(!(!(!(!(!(!(!(!(!(!(!(!(k
k
CATAWBA AVE.FOOTHILL BLVD.CATAWBAAVE.TOKAYST.FOOTHILL BLVD.COOPERST.PAINE ST.
MONICA ST.
PAINE ST.ALMERIA AVE.TOKAY AVE.TOKAYAVE.BARBEE AVE.CHERIMOYADR.CATAWBAST.CITRUSAVE.REED DR.REED DR.ALMERIAAVE.BARBEE ST.
REED CT.ALMERIAAVE.FOOTHILL BLVD.FOOTHILL BLVD.TOKAYAVE.BARBEE ST.ALMERIAAVE.MISSION ST.ALMERIAAVE.TOKAYAVE.HARVEY DR.CITRUSAVE.FOOTHILL BLVD.CITRUSAVE.CITRUSAVE.FOOTHILL BLVD.EUGENIAAVE.PAINE ST.
MONICA ST.CONCORD AVE.CONCORD AVE.MISSION ST.
MONICA ST.
HANOVER LN
SOUTHERN PACIFIC RR.
ETIWANDA VINEYARDS
GRIEF BROS. CORP.
MEADOWOOD APARTMENTSMEADOWOODAPARTMENTS
SOTHERNPACIFICELECTRICR/W
FOOTHILL
STOREMORE MINI STORAGE
AT&SFRR.22624
9899
161718191119181716151413393736303132333435363738391415343536372438404121 19
27 2129 11415162515122413
14
13
111920212224 232391718252612
2112 6
451415171819202122282726252423213534765431161718192021222423333231789132324252627282930313233343638
37
39
40
1
1211109865431113 337
6
5
1
3
4
2
15
8
323272625221935716292833132
142
131
144
129
3433
25
20
28
32
23
22
30
31
7
2121110 111
115
126
127
114
26
91028
29 303132222717 18162612520 3
2
4
56791011121314
204140302928272625381012131415161718238222138 37
41 42
36 35
245678311092429
31
15
34353637
89
32 106 7 8 9
30
14
112015783157917975
7965
157771562515645157801568715705156917943
15743157551577515690156551566515675160151602516070160851574515753157657915
794515735
79607955
7955
1574080511602015696157307935
7925
15733160201569916040156151568515695156547915
15723157271567015676156941565815662156701568215750157401568316070160807950
15692156987940
7930
8041
1592615976157837
8
7
5
157551587615922 160651571515694157151596815840157631577515785156481605016060157251572915671156771571515721157251573515735157478184
7965
15701157131572516035156971565715665160901565615662160457991 160751605516065160751608578961574515755
15705159608172
8183
8163
8173 159208174 16105161157959 1611016104157827935
7941
7945157021571015722157881575415760
160108050
8020
79081577615780
15685813215979 16090160958041
157828192819315635157651565715651158678146 16075157021577015681156961572815798157901608015650156537920 160907945
157911579315789157221577015760157341574015690157978160 15825157208021
7980
7955
7975
1582515756 1599315797802115795157641564215654
1563415660156581568615680158088137156771610215665157901571815730157427993
160551584015915159908164
7963
1567515651156731573515845 1/21572337782
8208156631565715710 7905
160601608016095158917987
1603416020
158458173
8173 1/2
8181
8197
8205
16212
8197
16063 1610016103161008184
1609416086160788196
161241606616062160481604016030160181601015643156201563015644156027960
7950
7938
15633156411560515615156251564515610157927953
156201563115645156407922
156387980
7990
161107954
7942 156351576315688156741568015630156871569115710157907995
1594015930159501570015714157201572615734157401575415760157661577415780157071571315719157271573315741157471575315761157671577315781157918198
8164
8174
8184
8192
8198
8210 8207
8197
8191
8183
8173
8163157081574615790 1611916125-271613316119 IRR156841570624" Casing 1886-1F
16" I.D. 3/16" WALLBore Casing
28" ZWBV Bore Casing 2584F-4 1986
15" I.D. 1/4" WALLBore Casing
26" KWBV Bore Casing2904F-1 1987 26" ZWBV
Bore Casing
10" x 8"
8" x 6"6" x 4"12" x 10"12" x 10"12" x 10"16" x 12"
16" x 12"
10" x 8"
6" x 4"
10" x 8"
16" x 12"8"PKHN2150F-119796"PKHN 2150F-1 1979 6"PKHN2150F-119796"PKHN 2150F-1 1979
6"PKHN 2150F-1 1979
85/8"FWBR1886-1F19708 5/8" FWMR 1886-4F 1970
8 5/8" GWBR 4908F-1 2004
8 5/8" GWBR4908F-1 20048"GWBA 260 1926
17 3/8" GWBR 4523F-1 2001
17 3/8" GWBR
4523F-1 2001
12 3/4" GWMR4342F-1 1999
12 3/4" GWBR4342F-1 1999
8 5/8" GWBR4342F-3 1999
12 3/4" FWCR1273F 1957
12 3/4" GWBR4446F-4 20008" PKHN 2420F-1 19828" PKHN 2150F-1 1979
6"PJKN1853-1F197012 3/4" FWMR 1273F 1957
12 3/4" GWMR 4244F-1 1998
8" PKHN 2150F-1 1979
85/8"FWMR1886-1F197012 3/4" GWBR
4244F-1 1998
17 3/8" GWMR 4908F-1 2004
4 1/2" GWBR4908F-1 200417 3/8" GWMR 4908F-1 2004
12 3/4" GWBR 4908F-1 200412 3/4" GWBR 2584F-4 1986
12 3/4" GWBR 4908F-1 2004
6 5/8" FWMR 1886-4F 19708"PKHN2640F-119856" QYQN 3122F-1 1989
6 5/8" GWBR 3673F-1 199312 3/4" GWMR 3673F-1 19936 5/8" GWBR3673F-1 19936 "P K H N 2 5 5 3 F -3 1 984
12 3/4" GWMR3673F-1 1993
12 3/4" GWBR4342F-1 1999
12 3/4" GWBR 4244F-1 199812 3/4" GWMR 4244F-1 199810 3/4" GWBR1273F 1957 INSIDE
10" PKHN 2082F-1 1977
6" GWBA 357 19326 5/8" GWBR 3673F-1 1993
6"GWBA357193212 3/4" FWCR1273F 19578 5/8" GWMR4342F-3 199912 3/4" FWMR1273F 1957
12 3/4" GWMR
4342F-1 1999
17 3/8" GWMR4908F-1 2004
17 3/8" GWBR 4523F-1 200117 3/8" GWBR 4523F-1 2001
12 3/4" GWBR 2584F-4 1986
10" PKHN 2584F-1 1986
6 5/8" GWBR4244F-1 1998
12 3/4" GWMR 4244F-1 1998
17 3/8" GWBR 4523F-1 2001
8 5/8" FWMR 1886-1F 1970
12 3/4" FWMR1853-1F 1970
12 3/4" FWMR1273F 1957
17 3/8" GWBR 4908F-1 2004
17 3/8" GWMR 4908F-1 2004
17 3/8" GWBR4523F-1 2001
8 5/8" FWMR 1886-1F 1970
8"PKHN 2584F-1 1986
10" PKHN 2584F-1 198610" PKHN2584F-1 19868"PKHN 2584F-1 1986
8" QYHN 2828F-1 1986
8" QYHN 3043F-1 19878" QYHN2828F-1 19868"QYHN 2828F-1 19868"QYHN 2827F-1 1986
8" QYHN 2823F-1 1986
6" PJKN 1937-1F 19716" PJKN 1853-1F 1970
4" JLEK 1853-1F 1970
17 3/8" GWMR
4908F-1 2004
6" PJKN 1853-1F 1970
17 3/8" GWMR 4908F-1 2004
17 3/8" GWBR 4523F-1 2001 123/4"GWMR3673F-119938 5/8" GWMR
4342F-3 1999
12" LCCG 1853-1F 1970
8" PKHN 2474F 19838" PKHN 2474F 198312" DWBB 1273F 1957
12 3/4" GWBR 4446F-4 20006" GWBR 357 19328" QYHN 2823F-1 1986
8" PKHN2474F 198317 3/8" GWBR 4523F-1 20018" QYHN2823F-4 19868" G WBA 260 192 68" QYHN2823F-1 19868" QYHN2823F-1 1986 12 3/4" GWMR 3673F-1 19936" LCCG 997 19528 5/8" GWBR 5792F-1 2014 10" PKHN 2584F-1 19868" QYHN 3043F-1 19878" QYHN 3043F-1 19878 5/8"GWBR 5837F-1 2014
6" PJKN 1853-1F 19704" BWAL 752 19464"BWAL 752 1946
6 5/8" GWBR 6265F-1 2018
6 5/8" GWBR 6265F-1 2018628756548165478655266552865473652886535365532655246555365523655316552765525652526522665237652256525465304
65308
6548065460324726545865459654796548265555524126523665233652346525365354653576535665359653356528965352653516369565355611136250665551655474006965605 65601655466518365182651416509573934 5994971865 4360745122
38496
392093448065137 55965
65100650946509665048650746560465056
655746557240352
45761600045264166013
66016660176556765053
61950619516543265050654576513665055
65057
65058
4576365358702047468574684655686557065456
5994659950601226039365521130301898665099650976523565188654125994561530599483363263226079865052
65051
26313
35236
934539469
983066141
66015656066997165455 37782475994759864915
5995265409650493448165054 5691060439649163946739466 457624512466215
6961765301
63504 93489349934793465240016780
1048310715110911109266174
6513860448651406455940503651396509865232652406519065181651846444965433650936507566175
66012
66140
4050266014
51935
43820
6444866150
45822
69562 40504604496541365411652295908266022
37861
66148
66149
64421601096603566033659576585265231591776523066023661516584365958
654356518653551489546522866025575706555064917655486557365571441955433840506405074365165251
63479655496584166027655696556665565658356077769957
71707
61639
69963
3947065844652506522742277653486541066026660286583465302464796543465431652856603465954659536595189769053600
14
65303
65307
899074037 70906
70558
19736 18987
40347
65292
65291
65305 64914652856529065239652386528765475655291326460440655546555265603871987319051612036135165189651876518565474655307621975911759127591375914759157591775918759197592075921759237592575926759277592875929759307593175932759337593475935759367593775909 IRR75924 IRR.77014
78706
78707
78708
78709
78710
78711 78726
78725
78724
78723
78722
7872175922759167591065306 357386979069791357395241359947A
A
B
C
A
E
F
G
BA
B
G
1" AV
4" FIRE SERVICE4198F-1 199845123
6" FIRE SERVICE4586F-1 2002529616" FIRE SERVICE5376F-1 2009698666" FIRE SERVICE3401F-1 1990
392094" FIRE SERVICE2377F-2 19812631310" FIRE SERVICE3495F-1 1991394686" FIRE SERVICE2931F-1 1987336338" FIRE SERVICE5732F-1 2013
74683
8" FIRE SERVICE2772F-2 198631175
4" FIRE SERVICE3307F-1 198936856
8" FIRE SERVICE4446F-1 200049614
6" FIRE SERVICE4342F-5 199947600
8" FIRE SERVICE2684F-3 1985
30057
BV9967 BV9964
BV9966BV996530333034
BV8687
8686
3032BV11732 2981BV11730
BV1173173777447744574437444
74467448
1406914070BV11722
585437833781377937803782
37843035BV11727BV11726
BV11720
BV11721BV11725
5389 539153906057
BV9139BV9137BV86837450BV9138
BV8684BV11729BV1172811718
5388
5591
559013225
14054
3090
29862984
2985
2983
BV11719 5387BV11724
5393 7441BV947412217BV8685
727
3526
35277442
7449559855965594 5595
5599
5597
BV11723 14501605960581450314502
11733
1572915728
FH 2401F
FH 2647FFH 4019FFH 5032F
FH 5033FFH 2754FFH 2649FFH 2646FFH 2478FFH 2101FFH 2400F
FH 1515F
FH 3556FFH 5031FFH 2280F
FH 3673FFH 4212FFH 5030F
FH 3060FFH 1636FFH 2648FFH 1512F
FH 1513F FH 1514FFH 988F
FH 4068FFH 5029FFH 2645FFH 1025F FH 1511FFH 2542FFH 5647FFH 2955F
FH 4316FFH 2644FFH 2482FFH 2481FFH 2479FFH 2480FFH 1516F
FH 938FFH 5991FFH 5732FFH 5733FFH 5734FFH 1322F57 ' 48.5 ' 5 ' 8 ' 16 ' 28 ' 15 ' 13 ' 13 ' 13 ' 10 ' 39 ' 47 ' 47 ' 43 ' 30 ' 8 ' 11 ' 11 ' 8 ' 14 '
15 ' 28 ' 12.5 ' 12 ' 24 ' 42 ' 14 ' 24 ' 8.5 ' 8 ' 30 ' 29 ' 47 ' 7 '
29 '
29 '
29 '
22 '
29 '
37 ' 16 '
16 '
10 ' 8 ' 8 ' 95 ' 8.5 ' 12.5 ' 45 ' ±FWC WATER ATLAS BOOK DISCLAIMER:
This map represents a visual aid intended to assist Public Utility Department personnel
with the management of Water System facilities. Data provided hereon is not a guaranteeof actual field conditions nor a substitute for record drawings and field verification.
Old Map
NOT FOR CONSTRUCTION USE
Scale: 1" = 100'
8215 Jan 15, 20208115
8114 8214 8314
8315
831682168116
8215 127, 128, 147, 148
WATER METER & RPZA
6 2ΤΓΥΥΩΤΓ.ΘΥΥ%ΩΤΞΓΨΚςϑ5ςΤΧΚΠΓΤ
4ΧςΓΘΗ(ΝΘΨ)2/2ΤΓΥΥΩΤΓ.ΘΥΥ25+6 2ΤΓΥΥΩΤΓ.ΘΥΥ%ΩΤΞΓΨΚςϑ5ςΤΧΚΠΓΤ
4ΧςΓΘΗ(ΝΘΨ)2/2ΤΓΥΥΩΤΓ.ΘΥΥ25+6 2ΤΓΥΥΩΤΓ.ΘΥΥ%ΩΤΞΓΨΚςϑΘΩς5ςΤΧΚΠΓΤ
4ΧςΓΘΗ(ΝΘΨ)2/2ΤΓΥΥΩΤΓ.ΘΥΥ25+2ΤΓΥΥΩΤΓ.ΘΥΥ%ΩΤΞΓΨΚςϑ5ςΤΧΚΠΓΤ
6 2ΤΓΥΥΩΤΓ.ΘΥΥ%ΩΤΞΓΨΚςϑ5ςΤΧΚΠΓΤ
4ΧςΓΘΗ(ΝΘΨ)2/2ΤΓΥΥΩΤΓ.ΘΥΥ25+6 #ΕΕΩΤΧΕ[%ΩΤΞΓ
4ΧςΓΘΗ(ΝΘΨ)2/#ΕΕΩΤΧΕ[6 #ΕΕΩΤΧΕ[%ΩΤΞΓ
4ΧςΓΘΗ(ΝΘΨ)2/#ΕΕΩΤΧΕ[6 #ΕΕΩΤΧΕ[%ΩΤΞΓ
4ΧςΓΘΗ(ΝΘΨ)2/#ΕΕΩΤΧΕ[6 #ΕΕΩΤΧΕ[%ΩΤΞΓ
4ΧςΓΘΗ(ΝΘΨ)2/#ΕΕΩΤΧΕ[
6 2ΤΓΥΥΩΤΓ.ΘΥΥ%ΩΤΞΓΨΚςϑ5ςΤΧΚΠΓΤ
4ΧςΓΘΗ(ΝΘΨ)2/2ΤΓΥΥΩΤΓ.ΘΥΥ25+6 2ΤΓΥΥΩΤΓ.ΘΥΥ%ΩΤΞΓΨΚςϑ5ςΤΧΚΠΓΤ
4ΧςΓΘΗ(ΝΘΨ)2/2ΤΓΥΥΩΤΓ.ΘΥΥ25+6 2ΤΓΥΥΩΤΓ.ΘΥΥ%ΩΤΞΓΨΚςϑ5ςΤΧΚΠΓΤ
4ΧςΓΘΗ(ΝΘΨ)2/2ΤΓΥΥΩΤΓ.ΘΥΥ25+6 #ΕΕΩΤΧΕ[%ΩΤΞΓ
4ΧςΓΘΗ(ΝΘΨ)2/#ΕΕΩΤΧΕ[6 #ΕΕΩΤΧΕ[%ΩΤΞΓ
4ΧςΓΘΗ(ΝΘΨ)2/#ΕΕΩΤΧΕ[6 #ΕΕΩΤΧΕ[%ΩΤΞΓ
4ΧςΓΘΗ(ΝΘΨ)2/#ΕΕΩΤΧΕ[
#
∃
∋
%
&
(
HUNSAKER
& ASSOCIATES
I R V I N E , I N C .
PLANNING
ENGINEERING
SURVEYING
GOVERNMENT RELATIONS
IRVINE
LOS ANGELES
RIVERSIDE
SAN DIEGO
FOUNDING PARTNERS:
RICHARD HUNSAKER
TOM R. McGANNON
JOHN A. MICHLER
DOUGLAS G. SNYDER
PRINCIPALS:
FRED GRAYLEE
BRADLEY HAY
PAUL HUDDLESTON
KAMAL H. KARAM
DOUGLAS L. STALEY
KRIS WEBER
JOSEPH E. WIGHTMAN
Three Hughes
Irvine, California
92618-2021
(949) 583-1010 PH
(949) 583-0759 FX
www.hunsaker.com
Sewer System Hydraulic Analysis
Date: July 20, 2021
For: City of Fontana By: Katie O'Connor, P.E.
Hunsaker & Associates Irvine, Inc.
Project:Begonia Village at Route 66
Hunsaker & Associates Irvine, Inc. (H&A) is pleased to submit the Sewer System
Hydraulic Analysis for the Begonia Village at Route 66 project. This analysis has
been prepared to describe the proposed sewer system for the aforementioned multi-
family development project in the City of Fontana. The project lies within the
jurisdiction of the City of Fontana and their standards have been used for this report.
Hydraulic models were prepared using Bentley Systems modeling software to model
the peak flows the proposed sewer systems would experience.
THE PROPOSED SEWER COLLECTION SYSTEM FOR BEGONIA VILLAGE AT
ROUTE 66 PROJECT MEETS THE DESIGN STANDARDS SPECIFIED BY THE
CITY OF FONTANA.This evaluation is based on existing and known conditions and
should be re-evaluated if these conditions change or new information becomes
available. Any interpretation of the information presented in this report should be
referred to H&A to ensure the integrity of the results.
Project Location
The Begonia Village at Route 66 project is located adjacent to Foothill Blvd. in the
City of Fontana. The general project location is shown on exhibit entitled, “Vicinity
Map.”
Summary of Findings
1. The development will include 423 multi-family dwelling units on a 10.64 acre
site in the City of Fontana at the corner of Foothill Blvd. and Tokay Avenue.
2. The proposed sewer private onsite sewer main/ lateral connection into the
existing sewer system has be analyzed to ensure sufficient capacity. The
attached “Sanitary Sewer Exhibit” identifies point of sewer connection as well
as the proposed and existing sewer mains.
3. The proposed onsite sewer collection system consists of 8-inch diameter
mains to be constructed at slopes of one percent or greater.
4. The total estimated sanitary sewer flows for the proposed Begonia Village at
Route 66 were based upon the City of Fontana design criteria as provided for
in the City of Fontana 2013 Sewer System Master Plan. The sanitary sewer
flows include the estimated future wastewater flows from the drainage area
based upon the proposed land use. Table 4-3 from the City of Fontana 2013
Sewer System Master Plan identifies the multi-family residential design unit
flow rate of 5200 gallons per day per acre (gpd/acre) and 289 gpd/unit.
H&A G-4 4/14/98
Sewer System Analysis
Begonia Village at Route 66, Fontana
July 20, 2021
Page 2
Table 1: FLOW RATES PER 2013 SEWER MASTER PLAN
LAND USE NUMBER
OF
UNITS
AREA
(acres)
UNIT FLOW
RATE
(gpd/unit)
FLOW RATE
(gpd)
FLOW
RATE
(cfs)
Multi-family
Residential
423 10.64 289 122,247 0.19
5. The sewer system for Begonia Village at Route 88 was designed to meet all
of the design criteria contained within the City of Fontana standards
6. In order to calculate the pipe sizes and capacity of the proposed sewer
system for Begonia Village at Route 66, we have prepared a hydraulic model
using Bentley FlowMaster V8i. The summary of outputs from the model runs
is included in the Appendix of this report.
We sincerely trust these calculations will provide sufficient evidence that the
proposed sewer system is adequate for the proposed Begonia Village at Route 66.
Please contact me at (949) 458-4537 if you have any questions.
KO:klo
Enclosures
xc:Ben Etemadi, H&A
Tin Huynh, H&A
W.O. 4423-8
(\\ashur\projects\1187\Engineering\SY_WS Study\Sewer\Fontana_SS report.doc)
Map No. 127 1 in = 150 ft ¯TOKAY AVE
I R V I N E , I N C .
PLANNING
PH: (949)583-1010
SURVEYING
FX: (949)583-0759Irvine, CA 92618Three Hughes
ENGINEERING
APPENDIX
Begonia Village at Route 66, Fontana
Proposed Onsite Sewer System
FlowMaster Calculations
BASE.fm8 Project Engineer: Hunsaker & Associates Inc
7/14/2021 12:50:00 PM Bentley Systems, Inc. Haestad Methods Solution Center FlowMaster [08.01.058.00]
27 Siemons Company Drive Suite 200 W Page 1 of 1
Watertown, CT 06795 USA +1-203-755-1666
Project Description
Worksheet:Reach - 1
Flow Element:Circular Pipe
Friction Method:Manning Formula
Solve For:Normal Depth
Input Data
Roughness Coefficient 0.013
Channel Slope 0.010 ft/ft
Diameter 8 in
Discharge 0.19 ft3/s
Results
Normal Depth 2.16 in
Flow Area 0.08 ft²
Wetted Perimeter 0.73 ft
Top Width 0.59 ft
Critical Depth 0.20 ft
Percent Full 26.60 %
Critical Slope 0.00644 ft/ft
Velocity 2.52 ft/s
Velocity Head 0.10 ft
Specific Energy 0.28 ft
Froude Number 1.25
Maximum Discharge 1.32 ft3/s
Discharge Full 1.22 ft3/s
Slope Full 0.00024 ft/ft
Flow Type SuperCritical
RAMPUP@5.9%SLOPEUPDNLEGEND DESCRIPTION
1/21/2021
UTILITY DESIGN SOLUTIONS
Attn: JUDY MUNN
30211 AVENIDA DE LAS BANDERAS, SUITE 200
RANCHO SANTA MARGARITA, CA 92688
RE: Will Serve Letter Request for Job I.D.#41-2021-01-00041
Location: 15926 FOOTHILL BLVD, CITY OF FONTANA
Dear JUDY MUNN:
Thank you for inquiring about the availability of natural gas service for your project. We are pleased to inform you that
Southern California Gas Company (SoCalGas) has facilities in the area where the above named project is being proposed.
The service would be in accordance with SoCalGas’ policies and extension rules on file with the California Public Utilities
Commission (Commission) at the time contractual arrangements are made.
This letter should not be considered a contractual commitment to serve the proposed project, and is only provided for
informational purposes only. The availability of natural gas service is based upon natural gas supply conditions and is
subject to changes in law or regulation. As a public utility, SoCalGas is under the jurisdiction of the Commission and
certain federal regulatory agencies, and gas service will be provided in accordance with the rules and regulations in effect
at the time service is provided. Natural gas service is also subject to environmental regulations, which could affect the
construction of a main or service line extension (for example, if hazardous wastes were encountered in the process of
installing the line). Applicable regulations will be determined once a contract with SoCalGas is executed.
If you need assistance choosing the appropriate gas equipment for your project, or would like to discuss the most effective
applications of energy efficiency techniques, please contact our area Service Center at 800-427-2200.
Thank you again for choosing clean, reliable, and safe natural gas, your best energy value.
Sincerely,
Nicole Kiyohiro
Technical GIS Supervisor
NK/SV
enc.
Southern California Gas Company
1981 West Lugonia Avenue
Redlands, CA 92374
Mailing Address:
PO Box 3003
Redlands, CA 92373-0306
City Council
Acquanetta Warren
Mayor
Jesse Armendarez
Mayor Pro Tem
John B. Roberts
Council Member
Jesus “Jesse” Sandoval
Council Member
Phillip W. Cothran
Council Member
CITY OF FONTANA 8353 SIERRA AVENUE, FONTANA, CALIFORNIA 92335
www.Fontana.org
November 30, 2020
Ben Etemadi
Project Manager
Hunsaker & Associates
3 Hughes
Irvine, CA 92618
Subject: Sewer Availability Letter for Assessor Parcel Number’s
1110-361-15, 1110-361-16, 1110-361-22, and 1110-361-23
Dear Mr. Etemadi:
This is to inform you that the sanitary sewer facilities provided by the City of
Fontana are available for connection to the parcels identified as Assessor
Parcel Number’s 1110-361-15, 1110-361-16, 1110-361-22, and 1110-361-23.
Please note that sewer connection is not a City requirement as a function of
sale of the property.
Should you have any questions regarding this matter, please contact the
project engineer, Esmeralda Gomez, at (909) 350-6552, or by email at
ejgomez@fontana.org
Sincerely,
DEPARTMENT OF ENGINEERING
Land Development Section
Esmeralda Gomez
Associate Engineer
3939 E. CORONADO ST. 2ND FLOOR ANAHEIM CA 92807
Jan 7, 2021
Utility Solutions, LLC
30211 Avenida De Las Banderas, Suite 200
Rancho Santa Margarita, CA 92688
Attn: Judy Munn
RE: Will Serve Letter, Foothill Blvd & Tokay, Fontana, CA
Dear Ms Munn,
This letter acknowledges that Foothill Blvd & Tokay, Fontana, CA is located in an area served by AT&T.
Any service arrangements for Foothill Blvd & Tokay, Fontana, CA will be subject to later discussions and
agreements between the developer and AT&T. While AT&T has the capacity to serve the project, please
be advised that this letter is not a commitment by AT&T to provide service to Foothill Blvd & Tokay,
Fontana, CA.
Please contact me at the phone number included in this letter with any questions.
Thank you for contacting AT&T.
Sincerely,
Marc Poole
Manager (OSP) Planning and Engineering
(951) 359-2629
mp2763@att.com
MP/rb
Will Serve Letter
1/8/2021
Judy Munn
Utility Design Solutions, LLC
30211 Avenida De Las Banderas Ste 200
Project Name:WSL - 15926 Foothill Blvd Fontana CA 92335
LOCATION:15926 Foothill Blvd Fontana CA 92335
Construction Manager Contact:
Claudia Payne
South Region Specialist, Business Development
7337 Central Ave
Riverside, CA 92504
951-406-1613
claudia.payne@charter.com
Sincerely,
Rancho Santa Margarita CA 92688
Re: May Serve Letter by Charter Communications or an affiliate authorized to provide service (“Charter”)
Thank you for your interest in receiving Charter service. The purpose of this letter is to confirm that the Property is within an area that
Charter may lawfully serve. However, it is not a commitment to provide service to the Property. Prior to any determination as to whether
service can or will be provided to the Property, Charter will conduct a survey of the Property and will need the following information from
you:
- Exact site address and legal description
- Is this an existing building or new construction?
- Site plans, blue prints, plat maps or any similar data
- The location of any existing utilities or utility easements
- ________________________________________________
Please forward this information to the construction manager listed below. Upon receipt, a Charter representative will be assigned to you
to work through the process. Ultimately, a mutually acceptable service agreement for the Property will be required and your cooperation
in the process is appreciated.