HomeMy WebLinkAbout5217-1GENERAL SEVVM NOTES,
I ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA
STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS
FOR PUBLIC WORKS CONSTRUCTION (-GREEN BOOK-). ALL REFERENCE
SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION
UNLESS OTHERWISE NOTED.
2 WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT
CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN
BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY
ENGINEER FOR RESOLUTION.
3 ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4 CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY
DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK.
INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO
THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS.
CALL (909) 350-7610.
5 THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND
PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST
NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
6 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES,
DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES.
7 THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK
FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION
OF INDUSTRIAL SAFETY.
8 THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH
SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS
PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE
OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN
THE POTENTIAL EXISTS FOR GROUND MOVEMENT.
9 NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT-OF-WAY WITHOUT
OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE.
10 THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE
INFORMATION. HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR
TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING
UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO,
THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600
TWO WORKING DAYS BEFORE EXCAVATION.
11 THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES
INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION,
LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER,
STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE
GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES.
12 THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT
APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE
WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS.
13 STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED.
14 ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE
THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL
BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL
STAKING DURING CONSTRUCTION.
15 THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT
TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
16 REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY
MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED
CIVIL ENGINEER OR LICENSED LAND SURVEYOR, SURVEY MONUMENTS THAT WILL BE
DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR
SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS
CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT.
17 THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL
TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION
AREA FOR RESIDENTS AND EMERGENCY VEHICLES.
18 THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL,
INCLUDING ADEQUATE WATERING, AT ALL TIMES.
19 THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS
TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT-OF-WAY
DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL
20 NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
21 A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE
TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION
OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED.
22 CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING
STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE
TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
23 ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH
TO MATCH EXISTING CONCRETE.
24 IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE
A TERMINAL CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE
DOWN STREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT.
25 SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE
VITRIFIED CLAY PIPE (V.C.P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS
OF THE ASTM DESIGNATION C700 FOR V.C.P..
26 NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL
OF THE CITY ENGINEER.
27 SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE
WALLS TO ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT.
28 PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND
VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS
TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS
SHOWN ON THE PLANS.
29 ALL 4' HOUSE LATERALS SHALL BE INSTALLED AT A 27 MINIMUM GRADE UNLESS OTHERWISE
APPROVED BY THE CITY ENGINEER.
30 TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12'
BELOW THE GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE
STREET RIGHT-OF-WAY, THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS
MEASURED FROM THE UTILITY EASEMENT.
31 THE SEWER CONTRACTOR SHALL STAMP AN "S' IN THE FACE OF THE CURB AT THE
LOCATION OF THE SEWER LATERAL
32 IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED
IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED
AGENCIES IMMEDIATELY.
33 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN
PLACED, INSPECTED AND APPROVED.
34 ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR
TO PAVING OF STREETS.
35 APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT
36 ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED
TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING
37 UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING
STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION
OF THE CITY TRAFFIC ENGINEER.
38 AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF
RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
CITY OF FONTANA
#N I I I.-
-S" SEWER IMPROVEMENT PLANS
TRACT NO. 18944
MATE ENGINEERS NOTICE TO CONTRACTORS
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN
ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS; TO THE BEST OF
OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE
PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO
PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE CONTRACTOR FURTHER
ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS OR
STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS.
THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY
FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT;
INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS SHALL APPLY
CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE
CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE ENGINEER
HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE
PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE
SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER.
CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT ALL
DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF ANY WORK. IT IS
THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE ENGINEER OF ANY
DISCREPANCIES. BEGINNING OF WORK MEANS ACCEPTANCE OF CONDITIONS.
CONTRACTOR SHALL COMPLY WITH ALL N.P.D.E.S. REQUIREMENTS.
CONTRACTOR SHALL ADJUST TO FINISH GRADE ALL MANHOLE RIMS, WATER VALVE BOXES,
UTILITY BOXES AND LIDS, ETC.
CONTRACTOR SHALL PROVIDE ALL THE NECESSARY PIPE FITTINGS TO COMPLETE THE WORK.
THE ENGINEER PREPARING THESE PLANS SHALL NOT BE HELD RESPONSIBLE OR LIABLE
FOR UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS. ALL CHANGES TO THESE
PLANS MUST BE REQUESTED IN WRITING AND MUST BE APPROVED BY THE ENGINEER OF
RECORD.
QUANTITIES SHOWN HEREON ARE PROVIDED FOR PERMIT AND BONDING PURPOSES ONLY.
CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THEIR OWN QUANTITIES PRIOR TO
BIDDING AND CONSTRUCTION. THE ENGINEER IS NOT RESPONSIBLE FOR DISCREPANCIES IN
FINAL CONSTRUCTION QUANTITIES.
NORTH SOUTH
OR OR
WEST EAST
R/W R/W
64'
0.5`. 5 6' 20' 20' 6' 5 0.5'
SAP,._
41MR
PROP. WATER
7' PROP. SEWER
0
PROP. SD 6' 5' 1
TYPICAL UNDERGMUN LTLU LOCATION
SCALE: 1"=10'
0
z
VONMY W
NOT TO SCALE
II
NOTM -TOP OF STRUCTURAL
t;j 1. TRENCH WIDTH SHALL BE CONTROLLED PAVEMENT 3� MAX.
SUBGRADE
AX SIZE
E TO TOP OF PIPE ZONE. . NATIVE
2. TRENCH DEPTHS OF GREATER THAN 5' SOIL COMPACTED 95%
SHALL HAVE ADEQUATE SHORING. 6 MIN. 6" MIN.
3. CLASS 11 AGG. BASE ALL TRENCHES f"O -MAX_ 10" MAX.
LESS THAN 100' IN LENGTH. NP
4. COMPACTION SHALL BE 90% IN ALL
ZONES UNLESS OTHERWISE SPECIFIED. :1 SLOPE OR FLATTER
TRENCH STABILITY SHALL CONFORM OR ADEQUATE SHORING
TO CAL -OSHA REQUIREMENTS.
5. THE SEWER PLUMBER TO VERIFY THE 6" MAX. SIZE- 1" MAX. SIZE
ULTIMATE BACKFLOW PREVENTION VALVE NATIVE SOIL
SIZE IL
0
COMPACTED 90% SELECTED NATIVE
fBEDDING COMPACTED
TO 90%
8" V.C.P. -
BEDDING MATERIAL SHALL MEET - - - - - - - - -
OR EXCEED SECTION 306-1.2.1,
STD. SPECS FOR PUBLIC WORKS
CONSTRUCTION, LATEST EDITION
LOCALLY EXCAVATED NATIVE MATERIALS
MAY BE BLENDED TO THE REQUIRED
SAND EQUIVALENCY OF 30 OR GREATER
TYP BEDDING FOR 8VCP
LESS THAN V DEEP
NTS
VARIES
'SNIV�
_v3�11� O?_
8" SEWER MAIN 12" MIN. CLEARANCE
(OR ENCASE IN CONCRETE)
2.00% MIN.
4" LATERAL
FLAT VM
SEE SHEET 4, LOTS 83 TO 87
NTS
C" OF FONTANA UTL17Y NOTIRCATION LIST
SEWER
CITY OF FONTANA
8353 SIERRA AVENUE
FONTANA, CA 92335
CABLE.-
TIME WAPMM CABLE
1205 DUPONT AVENUE
ONTARIO, CA. 91761
ELECTFtK>
SOUTHEM CALIFOFM COMPANY
7951 REDWOOD AVE.
FONTANA, CA. 92336
RECORD DRAWING
PHONE: 909.350.6632
GAS:
PHONE: 909.390.4738
TELEPHONE-
PHONE: 909.357.6221
WATER.
04/20/2020
SOUTMM CALFWNIA GAS COMPANY
AT+T
WEST VALLEY WATER DISTRICT
BENCH MARK: BM #67 BASIS OF BEARINGS:
16231 VALLEY BLVD.
FONTANA, CA 92335
PHONE: 909.428.8411
11464 TELEGRAPH ROAD 855 W. BASELINE ROAD
SANTA FE SPRINGS, CA 90670 RIALTO, CA 92377
PHONE: 714.666.5415 PHONE: 909.875.1361
SAN BERNARDINO COUNTY BENCHMARK
# 6-7. A BRASS DISK AT THE SOUTH-
CORNER OF CASA
T SA GRANDE AVENUE
.
THE BEARING OF NO(T3543*W ALO
THE C.L. OF SIERRA AVE., AS SHO
ON TR . 0
I _ .�NOg _14500 M.B. 251/7-
-1 _ .11
LEGEND
A.C. ASPHALTIC CONCRETE (R) RIDGE LINE
B.C. BEGIN CURVE R�W RIGHT OF WAY
TN
B.V.C. BEG. VERTICAL CURVE . TANGENT
B.W. BACK SIDEWALK T.C. TOP OF CURB
C.B. CATCH BASIN W WIDTH
C.L. CENTERLINE V VERTICAL DEPTH
E.C. END CURVE (590.69) INDICATES EXISTING ELEVATION
E.P. EDGE PAVEMENT 590.69 INDICATES PROPOSED ELEVATION
E.G. EDGE GRADE E.V.C. END VERTICAL CURVE [590.69] INDICATES FUTURE ELEVATION
F.L. FLOW LINE WRIN-MMM INDICATES SLOPE 2:1
F.S. FINISH SURFACE
G.B. GRADE BREAK AC PAVEMENT
H.P. HIGH POINT REMOVAL
INV. INVERT GRIND
D.C. ON CURVE
P.C.C. PORTLAND CEMENT CONCRETE EDGE OF PAVEMENT
CONSTRUCTION NOTES QUAMMES
INSTALL 8" EXTRA STRENGTH V.C.P. SEWER 5,870 L.F.
CONSTRUCT 48- PRECAST CONCRETE MANHOLE PER 23 EA.
CITY OF FONTANA STD. DWG. NO'S. 2000, 2001 & 2003
INSTALL 4" V.C.P. SEWER LATERAL AND CLEANOUT BOX - 5,750 L.F.
PER CITY OF FONTANA STD. DWG. NO. 2005. (180 EA.)
INSTALL BACKWATER VALVE DEVICE 91 EA.
U5 INSTALL SEWER PLUG 1 EA.
O LAY WYES FLAT 5 EA.
INSTALL 8" D.I.P. SEWER CL 350 WITH POLYETHYLENE WRAP- 162 LF.
ENGINEER OWNER/DEVELOPER.
MADOLE AM ASSOCIATES, INC. LCD SEM CREST LLC
CONSULTM CIVIL ENGNEERB 1155 N. MOUNTAIN AVE.
AND LAND PLANNERS UPLAND, CA 91786-0670
9302 PITTSBURGH AVE., SUITE 230 PHONE: 909.985.0971
RANCHO CUCAMONGA, CA 91730 CONTACT. STACEY SASSAMAN
HONE: 909.481.6322
FAX: 909.481.6320
CONTACT. MARK BEFITONE