Loading...
HomeMy WebLinkAbout0850-72_Baseline Avenue/Almeria Avenue - Sewer Project_4.4City of Fontana C ALIFORNIA May 4, 1993 Mr. Robert J. Johnson, P.E. C.H.J., Incorporated P.O. Box 231 Colton, CA 92324-0231 RE: Baseline/Almeria Sewer Project Executed Contract for Geotechnical Services Dear Mr. Johnson: Enclosed for your records is a fully executed copy of the Contract Documents for the Geotechnical Engineering Services for the Baseline Avenue and Almeria Avenue Trunk Sewer System. If you have any questions please call the undersigned at (909) 350-6645. Sincerely, COMMUNITY DEVELOPMENT DEPARTMENT Engineering Division Yousuf Patanwala Associate Engineer/Special Projects Enclosure c:\yousuf\leters93\excntgeo.bsl 8353 SIERRA AVENUE (P.O. BOX 518) • FONTANA, CALIFORNIA 92334-0518 • (714) 350-7600 SISTER CITY- KAMLOOPS, B.C. CANADA C i recycled paper PAYMENT/CONTRACT EXECUTION REQUEST TO: JAY M. COREY, CITY MANAGER FROM: BOB WEDDLE, CITY ENGINEER .1 DATE: MARCH 12, 1993 SUBJECT: CONSULTANT CONTRACT - BASELINE/ALMMIA SEWER PROJECT BRIEF BACKGROUND/SUMMARY: THE BASELINE/ALMERIA SEWt:R PROJECT HAS BEEN AWARDED BY COUNCIL ON MARC-I 2, 1993. THE CONSTRUCTION CONTRACTS ARE BEING ROUTED FOR SIGNATURE BY SEPARATE MEMORANDUM. THIS PROJECT REQUIRES THE SERVICES OF A SURVEYOR AND A GEOTECHNCIAL ENGINEER. THE SURVEYOR IS ALRADY ON CONTRACT (PFEIFER AND ASSOCIATES) TO DO THE CITRUS STORM DRAIN AND BASELINE/ALMERIA CONSTRUCTION SURVEYING. THIS IS FOR GEOTECHNICAL ENGINEERING SERVICES. WHILE PROCESSING THE CONTRACT FOR THE GEOTECHNCIAL CONSULTANT, THE CONTRACT DOCUMENTS WERE LOST AND THE ATTACHED IS THE NEW CONTRACTS TO PROCESS FOR SIGNATURE. BY MEMORANDUM ATTACHED (7/24/92) PURCHASING HAS INDICATED THE: FIRMS SELECTED FOR OUR THREE MAJOR PROJECTS . CHJ WAS SFT E(:1'bL) FOR THIS PROJECT. Vendor/Contract Name: CHJ INCORPORA'1') Contract Value $ 17,551 Document Authority from City Council: [ ] Yes Vx] No CITY MANAGER CONTRACT Budgeted: 071-7243 (OLD) [x4 Yes [ ] No 53720-53011403 (NEW) [ ] One -Time Cost [ ] Recurring Consistent with Purchasing Procedures: [x Yes [ ] No If not consistent, explain: SEE ATTACHED 7/24/92 PURCHASING CONCURRENCE STAFF APPROVAL: DEPARTMENT HEAD APPROVAL: DATE: `3/'•�4ss DATE: 3- S'• ) ITY MANAGER FINAL APPROVAL: _ DATE: Attachment: City Council Minutes and/or Page from Approved Budget Pol Yes [ ] No Other [ ] CITY OF FONTANA California MEMORANDUM TO: CLIFF STEWART, CENTRAL SERVICES MANAGER FROM: BOB MEDDLE, CITY ENGINEER RE: GEOTECINICAL SERVICES DATE: JULY 24, 1992 As we discussed when we reviewed the ranking of the engineering firms proposing on the four projects, staff contacted CHJ, the third ranked firm, as to their low fee. They indicated that their estimate of hours was based on their understanding of the project; however, in a practical sense, they believe the soils technician will have to be in the field a substantially longer period of time and real costs will be much higher. Therefore, on a qualifications based selections process, the firms of GPI, Leighton Associates and CHJ were the top ranked firms and it is proposed to spread the work out between the three firms in lieu of having only one firm with the total amount of work. 1. GPI: Cypress Sewer Construction Services 2. Leighton Associates: Citrus Storm Drain a. Design Report b. Construction Services 3. CHJ: Baseline/Almeria Sewer Construction Svs. Proposed Fee $43,720 $10,370 $16,381 $ 5,109(a) (a) Fee needs to be adjusted up for anticipated additional hours for full time soils technician presence as was required in Highland Haven project Final fee will probably be around $10400: If you concur with this methodology, please advise as staff needs to process the consultant services agreements as soon as possible. In summary, the top ranked firm is recommended for the largest project, the second for the next and so on CONC iff Stewart Central` Services Manager RWW:sh V/6/5 t 17(...e. v sd, /S or, .4 y MY' S e �,.: l ar• f d oZ // / =• -� r fa,./4 /Po1 /`! /. J — 6:/iitJi".J CITY OF-FONTANA 1992-93 ADOPTED BUDGET BY PROGRAM SEWER IMPROVEMENT FUND (071) EXPENSE CATEGORY 1992-93 1992.93 1992-93 1992-93 1992-93 1992-5 071-7244 071-3920 071-7218 071-7230 071.7239 071-724: PRE -TREAT ADMIN FTNL/BEECH NSTR SWR PLN TREE REPLC BSLN/ALMERIA PERSONAL SERVICES S51,321 $21,889 84,782 $7,884 $5,265 S37,957 OPERATING EXPENDITURES 5,000 6,940 0 0_ 0 300 CONTRACTUAL SERVICES 4,200,000 5,000 10,000 20,000 5,000 875,129 INTERNAL SERVICE CHARGES 7,196 0 0 0 0 0, CAPITAL EXPENDITURES 0 0 0 0 0 0 OPERATING TRANSFER 0 0 0 0 0 0 TOTAL BY CATEGORY $4,263,317 S33,829 $14,782 S27.,884 S10,265 S913,386 0.80 0.30 0.09 0.120 0.09 0.58 PERSONNEL BY OBJECT 1100 FULL -TINE EMPLOYEES 37,561 15,945 3,406 5,754 3,806 27,449 1155 ANNUAL LEAVE PAYOFF 1,728 733 1S7 26.5 175 1,263 1200 PART-TIME EMPLOYEES 1300 OVERTIME 1400 SPECIAL DUTY PAY 1600 INCENTIVE PAY 1800 POLICE UNIFORM ALLOWANCE 1900 AUTO ALLOWANCE 1902 PERS RETIREMENT 6,056 2,552 SS8 1905 CAFETERIA BENEFIT PLAN 4,868 2,124 548 1908 FICA HOSPITALIZATION 526 291 48 1909 WORKERS' COMPENSATION 582 218 65 1910 UNEMPLOYMENT INSURANCE 0 TOTAL PERSONNEL 0 0 0 0 26 208 0 0 927 760 87 618, 4,424 548 3,8c. 53 65 4ca. 51,321 21,889 4,782 7,884 5,265 37,957 OPERATING EXPENSES BY OBJECT 2000 DEPARTMENTAL. EXPENSES 5,000 2,625 2100 UNIFORM SUPPLIES 0 2200 ADVERTISING 0 300 2300 COMMUNICATIONS 0 1,360 2400 UTILITIES 0 2500 RENTS $ LEASES 0 759 2610 AUTOMOTIVE PARTS 0 2611 FUEL AND OIL 0 2612 TIRES AID TINES 0 2800 EQUIPMENT MAINTENANCE 0 300 3000 INSURNCE SETTLEMENTS 0 3100 MEMBERSHIPS i DUES 0 3200 CONFERENCES, TRAINING, MEETINGS 0 3210 ORGANIZATIONAL TRAINING 0 3400. MISCELLANEOUS EXPENSES 0 3450 DEPRECIATION - 0 3500 EMPLOYEE EDUCATION REINS 0 600 3600 INTEREST EXPENSE 0 300 • • CITY OF FONTANA 1992-93 ADOPTED BUDGET BY PROGRAM SEWER IMPROVEMENT FUND (071) EXPENSE CATEGORY 1992-93 1992-93 1992-93 1992-93 1992-93 1992-93 071-7244 071-3920 071-7218 071-7230 071-7239 071-7243 PRE -TREAT ADMIN FTHL/BEECH MSTR SWR PLN TREE REPLC BSLN/ALMERIA - gE,“- 3700 PRINCIPAL PAYMENT 0 3800 POSTAGE COSTS 0 3801 PHOTOCOPY COSTS 0 3802 DENTAL COSTS 0 3803 OFFICE SUPPLIES 0 3900 EQUIP/FURNITURE < $500/UNIT 0 996 TOTAL OPERATING EXPENSES 5,000 6,940 0 0 0 300 CONTRACTED PROFESSIONAL SERVICES 4000 LEGAL SERVICES 50,000 5,000 10,000 4100 ACCOUNTING & AUDITING SERVICES 50,000 4200 ENGINEERING SERVICES 4,050,000 20,000 68,000 4 4210 PLAN CHECK SERVICES 0 4220 INSPECTION SERVICES 0 4300 CONSTRUCTION COSTS 0 5,000 807,129 ` , 4600 OTHER PROFESSIONAL SERVICES 50,000 TOTAL CONTRACTED PROF SERVICES 4,200,000 5,000 INTERNAL SERVICE CHARGES BY OBJECT 2600 VEHICLE MAINTENANCE 0 2700 ,DATA PROCESSING CHARGE 0 3000 RISK LIABILITY 7,196 10,000 20,000 5,000 875,129 TOTAL INTERNAL SERVICE CHARGES 7,196 0 0 0 0 0 CAPITAL OUTLAY BY OBJECT 5100 VEHICLES & ROLLING STOOK 0 5200 MAINTENANCE & TESTING EQUIPMENT 0 5300 OFFICE EQUIPMENT & FURNITURE 0 5400 LAND S BUILDINGS 0 6080 PROJECT INNOVEMENTS 0 6090 DISPOSAL COSTS 0 6120 COST OF ISSUANCE 0 TOTAL CAPITAL OUTLAY 0 0 0 0 0 OPERATING TRANSFER TOTAL BY OBJECT 4,263,517 33,829 14,782 27,884 10,265 913,386 assasssass: a:ssssssaas aasssssaass saws CONSULTANT SERVICES AGREEMENT THIS AGREEMENT is made this day of , 1993, by and between the CITY OF FONTANA, a municipal corporation of the State of California, (hereinafter "City") and CHJ. Incorporated. (hereinafter "Consultant"). WHEREAS, the principal members of Consultant Robert J. Johnson. P.E.. Senior Vice President. and WHEREAS, City desires to engage Consultant to provide consulting engineering services for the Baseline/Almeria Sewer Project for geotechnical materials testing and reports. NOW, THEREFORE, CITY AND CONSULTANT MUTUALLY AGREE THAT: SECTION I SERVICES OF THE CONSULTANT General Description of Services. Consultant shall perform the tasks set forth in Exhibit "A" attached hereto and made a part hereof so as to fully and adequately complete their project described herein. SECTION II RESPONSIBILITIES OF CONSULTANT 1. Personnel. All the work shall be performed by Consultant or under its supervision. The Consultant represents that it possesses the professional and technical personnel required to perform the services required by this Agreement. City retains Consultant on an independent contractor basis and Consultant, shall not be considered to be an employee of the City. The personnel performing the services° under this Agreement on behalf of Consultant shall at all times be under Consultant's exclusive direction and control. Consultant shall pay all wages, salaries, and other amounts due such personnel in connection with their performance of services under this Agreement and as required by law, shall be responsible for all reports and obligations respecting them, including but not limited to, Social Security taxes, income tax withholding, unemployment insurance, and workers' compensation insurance. 2. Cooperation. Consultant shall work closely and cooperate fully with City's designated Project Administrator, and any other agencies which may have jurisdiction over or interest in the work to be performed. 3. Project Manager. The Consultant shall assign the project to a Project Manager, who shall coordinate all phases of the project. This Project Manager shall be available to the City at all times. The Consultant has designated Donald M. Mathews, P.E., to be its Project Manager. 4. AC Performance. The task tdie performed by Consultant under and pursuant to this Agreement shall be completed within 120 days from the date of the Consultants receipt of written authorization to proceed from the City. Consultant shall receive no 'additional compensation if completion of its obligation under this Agreement requires a time greater than as set forth herein unless such extension is caused solely by the conduct of the City. Each party hereby agrees to provide timely notice to the other of any violation occurring under this section and the cause thereof. 5. Report Materials. At the completion of this project, Consultant shall deliver to City all documents, data, studies, surveys, drawings, maps, models, photographs, and reports prepared by Consultant under this Agreement. Said documents shall be considered the property of City upon payment for services performed by Consultant. 6. City Policy. Consultant will discuss and review all matters relating to policy and project direction with the Project Administrator in advance of all critical decision points in order to ensure that the project proceeds in a manner consistent with City goals and policies. 7. Conformance to Applicable Requirements. All work prepared by Consultant shall conform to applicable city, county, state, and federal requirements and be subject to approval of the Project Administrator and City Council. 8. Indemnification. Consultant agrees to indemnify, save, and hold harmless City, its officers, agents, and employees from and against all liability, claims, damages, losses, and expenses for damages of any nature whatsoever including, but not limited to, bodily injury, death, personal injury, property damages, and attorneys' fees, directly arising from any and all negligent actions of Consultant, its employees, agents, or subcontractors pursuant to this Agreement. 9. Standard of Care; Licenses. Consultant represents and agrees that all personnel engaged in performing services are and shall be fully qualified and are authorized or permitted under state and local law to perform such services. Consultant shall perform the services under this Agreement in a skillful and competent manner. Consultant shall be responsible to City for any errors or omissions in the execution of this Agreement arising from Consultant's actions. Consultant represents and warrants to City that it has all licenses, permits, qualifications, and approvals required ofits profession. Consultant further represents and warrants that it shall keep in effect all such licenses, permits, and other approvals during the term of this Agreement. 10. Insurance. Without limiting Consultant's indemnification of City, Consultant shall obtain and provide and maintain at its own expense during the term of this Agreement a policy or policies of liability insurance of the type and amounts described below and satisfactory to the City Attorney. Such policies shall be signed by a person authorized by that insurer to bind coverage on its behalf and must be filed with City prior to exercising any right or performing any work pursuant to this Agreement. Said policies shall ' add as insured City•ts elected officials, officers,d employees for all liability arising from Consultant's services as described herein. A. Prior to the commencement of any services hereunder, Consultant shall provide to City certificates of insurance "with original endorsements, and copies of policies, if requested by City, of the following insurance, with Best's Class B or better carriers: (1) Worker's compensation insurance coverage as required by the laws of the State of California; (2) Commercial general liability insurance covering third party liability risks, including without limitation contractual liability, in a minimum amount of $1 million combined single limit per occurrence for bodily injury, personal injury, and property damage. If commercial general liability insurance or other form with a general aggregate limit is used, either the general aggregate shall apply separately to this project, or the general aggregate limit shall be twice the occurrence limit; (3) Commercial auto liability and property insurance covering any owned and rented vehicles of Consultant in a minimum amount of $1 million combined single limit per accident for bodily injury and property damage. B. Said policy or policies shall be endorsed to state that coverage shall not be cancelled by either party except after thirty (30) days prior notice has been given in writing to City. Further, Consultant shall give City written notice thirty (30) days prior to suspension, voiding, or reduction in coverage or in limits. Consultant shall give to City prompt and timely notice of claim made or suit instituted arising out of Consultant's operation hereunder.. Consultant shall also procure and maintain, at its own cost and expense, any additional kinds of insurance, which in its own judgement may be necessary for its proper protection and prosecution of the work. C. Consultant shall include subcontracting consultants, if any, as insureds under its policies or shall furnish separate certificates and endorsements for each subcontractor. All coverage for each subcontractor shall be subject to the requirements stated herein. D. All insurance obtained by Consultant hereunder shall be primary. Notwithstanding any insurance which may otherwise be obtained by City. 11. Prohibition Against Transfers. A. Consultant shall not assign, sublease, hypothecate, or transfer this Agreement, or any interest therein, directly or indirectly by operation of law without the prior written consent of the City. Any attempt to do so without said consent shall be null and void, Sd any assignee, sublessee,pothecatee or transferee shall acquire no right or interest by reason of such attempted assignment, hypothecation, or transfer. B. The sale, assignment, transfer, or other disposition of any of the issued and outstanding capital stock of Consultant, or of the interest of any general partner or joint venturer or syndicate member, or co -tenant if Consultant is a partnership or a joint venture or .a syndicate or a co -tenancy, which shall result in changing the control of Consultant, shall be construed as an assignment of this Agreement. Control means fifty percent (50%) or more of voting power of the corporation. 12. Progress. Consultant is responsible to keep the Project Administrator and/or his/her duly authorized designee informed on a regular basis regarding the status and progress of the work, activities performed and planned, and any meetings that have been scheduled or are desired. 13. Confidentiality. No news releases, including photographs, public announcements, or confirmations of the same, of any part of the subject matter of this Agreement or any phase of any program hereunder shall be made without prior written approval of City. The information which results from the services in this Agreement is to be kept confidential unless the release of information is authorized by City. SECTION III RESPONSIBILITIES OF CITY 1. Cooperation. City agrees to cooperate with the Consultant on the project. 2. City's Responsibilities. City shall furnish to Consultant base maps, existing studies, ordinances, data, and other existing information as shall be determined by Consultant and materials. in City's possession necessary for Consultant to complete the work contemplated by this Agreement. City further agrees to provide all such materials in a timely manner so as not to cause delays in Consultant's work schedule. 3. Administration. This Agreement will be administered by the City Manager's Office. The City Engineer or his/her designee shall beconsidered the Project Administrator and shall have the authority to act for the City under this Agreement. The City Manager or his/her authorized representative shall represent the City in all matters pertaining to the services to be rendered pursuant to this Agreement. SECTION IY FEES AND PAYMENTS 1. Compensation. Except as provided in this section, Consultant shall receive as compensation for all services rendered under this Agreement an amount not to exceed S17.551.00 and at the rates set forth in Exhibit "B". The total project cost shall not exceed this amount unless additional work is authorized in writing by the.City. City shall•t be required to pay any amo• in excess of this sum whether for copying costs, incidental, direct, or indirect costs, or any type incurred by Consultant. This section shall not limit the ability of the parties to amend this Agreement to provide for extra work. 2. Extra Work. Consultant shall receive compensation for extra work authorized by City in an amount as specified by the parties at the time such authorization is given. All extra work must be authorized in writing by the Project Administrator and Consultant shall not be entitled to extra compensation without such authorization. 3. Reimbursement for Expenses. .Consultant shall not be reimbursed for any expenses unless authorized by the City. 4. Monthly Invoices. Consultant shall submit invoices to the City on a monthly basis in accordance with Consultant's schedule of fees contained in Exhibit "B" hereof. Each invoice shall be itemized. Each invoice shall show the number of hours per person/consultant and the nature of the work performed. 5. Payment of Compensation. City shall make payments to Consultant within thirty (30) days of receiving said statement unless City disputes the amount Consultant claims is owed under this Agreement. 6. Withholdings. City may withhold payment of any disputed sums until satisfaction of the disputed withholding shall not be deemed to constitute a failure to pay according to the terms of this Agreement. Consultant shall not discontinue its work for a period of thirty (30) days from the date of withholding as a result of such withholding. Consultant shall have an immediate right to appeal to the Mayor and City Council with respect to such disputed sums. The determination of the Mayor and City Council with respect to such matters shall be final. Consultant shall be entitled to receive interest on any withheld sums at the rate of seven percent (7%) per annum from the date of the withholding of any amounts found to have been improperly withheld. 7. 10% Withholding. City may withhold an amount equivalent to ten percent (10%) of the total compensation provided herein, to be released to Consultant upon final adoption of the project by the Mayor and City Council. The City reserves the right to refuse to pay all billings requesting amounts in excess of 90% of the total compensation provided herein until the project is completed and adopted as specified above. SECTION V ACCOUNTING RECORDS Consultant shall keep records and invoices in connection with its work to be performed under this Agreement. Consultant shall maintain complete and accurate records with respect to the costs incurred under this Agreement. All such records shall be clearly identifiable. Consultant shall allow a representative of City during normal business hours to examine, audit, and make transcripts or copies of such records. Conliltant shall allow inspection ofl work, data, documents, proceedings, and activities related to the Agreement for a period of three (3) years from the date of final payment under this Agreement. SECTION VI GENERAL PROVISIONS 1. Termination. A. City may, by written notice to Consultant, terminate this Agreement at any time and without cause by giving written notice to Consultant of such termination, and specifying the effective date thereof, at least seven (7) kdays before the effective date of such termination. In the event of termination without cause, Consultant shall be compensated for the work performed up to the date of termination. Payment for work completed under the Agreement to date of termination shall be made strictly on the basis of the percent of services completed under, the terms of this Agreement. The percent of work completed to date of termination shall be the percent of the total compensation under this Agreement which shall be paid to Consultant. The City Manager shall determine the percent of work completed at the date of termination. In no event may total payment upon termination exceed S17.551.00. Consultant shall be entitled to no further compensation after termination. Consultant may not terminate this Agreement except for cause. B. In the event this Agreement is terminated, as provided in paragraph A of this section, City may procure from any person or entity upon such terms, and in such manner as it may determine appropriate, services similar to those terminated. C. If this Agreement is terminated as provided in paragraph A of this section, Consultant shall provide to City upon request by City all finished or unfinished documents, data, studies, drawings, maps, photographs, reports, etc., prepared by Consultant for the project as such time as final payment is made pursuant to paragraph A of this section. D. Consultant further covenants to give its good faith cooperation in the transfer of the work to any other consultant employed by City following termination hereunder, and to participate in a maximum of two meetings at no cost to City as shall be deemed necessary by the City Manager to effectively accomplish its transfer. 2. Notices. Any notice required or desired to be given pursuant to this Agreement shall be given in writing, and sent by certified mail, return receipt requested, addressed as follows: City Jay M. Corey City Manager City of Fontana 8353 Sierra Avenue Fontana, Ca. 92335 (714) 350-7654 Consultant Mr. Robert J. Johnson, P.E. Senior Vice President CHJ, Incorporated 1335 East Cooley Drive Colton, CA 92324 (714) 824-7210 S Any notice so given shall be considered served, on the other party three (3) days after deposit in the U.S. mail, first class ,,,postage prepaid, and addressed to the party at its applicable address. The address for notice may be changed by giving notice pursuant to this paragraph. 3. Litigation. Should litigation be necessary to enforce any term or provision of this Agreement, or to collect any portion of the amount payable under this Agreement, then all litigation and collection expenses, witness fees, expert fees, court costs, and attorney fees incurred by the prevailing party shall be paid by the losing party to the prevailing party. 4. Entire Agreement. This Agreement contains the entire agreement between City and Consultant with respect to the subject matter hereof and supersedes all prior negotiations, understandings, or agreements. This Agreement may only be modified by a writing signed by both parties. 5. Enforcement. This Agreement shall be construed and enforced in accordance with the laws of the State of California. 6. Nondiscrimination by Consultant. Consultant represents and agrees that Consultant, its affiliates, subsidiaries, or holding companies do not and will not discriminate against any subcontractor, consultant, employee, or applicant for employment because of race, religion, color, sex, handicap, or national origin. Such nondiscrimination shall include, but not be limited to, the following: employment, upgrading, demotion, transfers, recruitment, recruitment advertising, layoff, termination, rates of pay or other forms of compensation, and selection for training, including apprenticeship. 7. City's Rights to Employ Other Consultants. City reserves the right to employ other consultants in connection with this project. 8. Conflicts of Interest. A. Consultant or its employees may be subject to the provisions of the California Political Reform Act of 1974 (the "Act"), which (1) requires such persons to disclose financial interest that may foreseeably be materially affected by the work performed under this Agreement, and (2) prohibits such persons from making, or participating in making, decisions that will foreseeably financially affect such interest. B. If subject to the Act, Consultant shall conform to all requirements of the Act. Failure to do so constitutes a material breach and is grounds for termination of this Agreement by City. SECTION VII SUBCONTRACTING 1. Consultant shall not subcontract any portion of the services required by this Agreement, except as expressly stated herein, without prior approval of City. 2. Subcontracts, if any, shall contain a provision making them subject to all provisions stipulated in this Agreement. IN WITNESS WHEREOF, the parties hereto have accepted and made and executed this Agreement upon the terms, conditions, and provisions above stated, on the day and year first above written. CITY OF FONTANA A Municipal Corporation • y M. rey City r ager ATTEST: Kathy Mo oya City Clerk APPROVED AS TO LEGAL FORM: Cl aril Al sop or Stephen P. Deitsch City ttorney Ke - Jes Acting Robe Graham Risk Management ment Director CHJ Incorporated ROB EFII' J. JOHNSON SENIOR VICE PRESI * Notary *Notarization of signature is required for development, sub- division tract, landscape maintenance, and storm drain fee agreement; alldeeds, certificates of participation and •mpi annc a, and allother requirey state law. • EXHIBIT "A" SCOPE OF SERVICES Pipe Zone Backfill Backfill Subgrade b. the City of Fontana plans to bid this summer or fall the Baseline/Almeria Sewer Project and requires the services of an engineering geotechnical consulting firm to provide construction materials testing (see attached projectvicinity map) A. General Services 1. Provision of Geotechnical Services During Construction This proposal shall be based on tests being scheduled within 24 hours of the Inspector's request for tests. Results of these tests shall then be made available immediately in the field, followed by reports within 48 hours. In place soil densities shall be determined by the sand cone method of test in accordance with ASTM Standard D-1556-64, or by the nuclear method of test in accordance with ASTM Standard D-2922-071. Optimum soil moisture density relations shall be determined by the method of test specified in ASTM Standard D-1577-78. R-Value shall be determined by the stabilometer test (Test Method No. Calif. 301). The proposal shall be based on the following qualities of work or materials stated below. a. The following minimum tests at 300' intervals (except as noted on Project Specific Scope of Services) and upon 20% of estimated laterals. -Bedding (where applicable) -Bottom half of trench above Pipe Zone -Top half of trench above Pipe Zone -At finish subgrade plus R-Value 1500' to 2000' intervals). Include analysis and recommendation for structural section of A.C. pavement where applicable (number of tests is Project specific) Optimum Soil Moisture Density Test The .results shall, as a minimum, include the following information: 1. Test Site Station and Depth (relative to project drawings) 2. Moisture Content by percentage 3. Dry Density 4. Relative Compaction 5. Soil Type with maximum dry density and optimum moisture content 2. •Project' ecific Scopes - Construction S a. Baseline/Almeria Sewer Provision of Geotechnical Services During Construction of the Above Referenced Project. 'Project Characteristics: A set of plans is available for review. Project consists of the installation of 3,219 L.F. of 21" V.C.P. trunk sewer and 8" V.C.P. laterals on existing Baseline Avenue and 2,406 L.F. of 18" V.C.P. and 285 L.F. of 21" V.C.P. on future Almeria Avenue (on native ground at time of project). Pre -cast concrete manholes and related structures. Removal and reconstruction of pavement on Baseline Avenue. Scope of Services: See General Scope of Services A minimum of 3 R-Values shall be provided. DELINEATION OF RESPONSIBILITIES A. Responsibilities of the Enqineering/Geotechnical Consultant The Consultant is expected to provide the lead role in providing the testing services under the general direction of the inspector and engineer as appropriate. The Consultant must, on a regular basis, keep the Engineer informed of the status of the work and inform the Engineer as to any pertinent decisions that should be made for a quality constructed product. The Consultant may be called upon to attend meetings during any phase of the work to give technical advice or to inform various parties as to the status or nature of the work. At a minimum, the Consultant shall attend: 1. Construction projects "pre -job" meetings 2. Upon completion of the project work and submission/ review of final report EXHIBIT "B" SCHEDULE OF FEES (EFFECTIVE JANUARY 1, 1992) INCLUDED IN THIS SCHEDULE OF FEES ARE COSTS FOR SERVICES AND TESTS COMMONLY PERFORMED BY THIS FIRM. OTHER SERVICES OR TESTS, AS WELL AS COSTS FOR THESE SERVICES OR TESTS, CAN BE SUPPLIED UPON REQUEST. C. H. J., INCORPORATED 1355 East Cooley Drive Colton, California 92324 714/824-7210 • TABLE OF CONTENTS Soil Engineering / Technical Services Materials Engineering / Field Observation Services Conditions and Working Hours for Deputy Inspectors Laboratory Testing Services 1-2 3-4 5-6 7-14 • • SOIL ENGINEERING / TECHNICAL SERVICES SERVICES RATE PER HOUR Principal Engineer $ 95.00 Project Engineer (Registered) 75.00 Staff Engineer 55.00 Supervising/Senior Field Technician 48.00 Field Technician 47.00 Field Technician (Nuclear Gauge) 53.00 Supervising/Senior Laboratory Technician 48.00 Laboratory Technician 47.00 Drafting 32.00 Typing/Clerical 30.00 Litigation, Expert Witness & Preparation by Professional Engineer - 8 Hour Minimum (Plus Expenses) 150.00 Subsistence and Lodging - Per Day (Subject to Review for Specific Projects) 70.00 PREMIUM RATES A. Overtime (at Client's Request), add $ 16.00 B. Sundays and Holidays, add 28.00 NOTE: The hourly rates quoted above include all costs for Held equipment and vehicle' for which our Clients will pay no additional fee. -1- SOIL ENGINEERING AND TECHNICAL SERVICES (continued) SERVICES — OTHER RATE PER HOUR Engineering Geology or Engineering Geologist Quotation Computer Time (for Engineering Analysis) Cost + 20% Printing and Photographic Work Cost + 20% Subcontract Services Cost + 20% EOUIPMENT CHARGES FIELD EOUIPMENT Pick Up Truck and Automobile Mileage No Charge EXPLORATORY EOUIPMENT Drill Equipment Cost + 20% Backhoe Cost + 20% REPORTS — EXTRA COPIES Current Files (Not Over One Year Old) Minimum Service Charge, Per Report $ 7.50 Copies, Per Sheet 0.15 Inactive Files (One Year or Older) Minimum Service Charge, Per Report 10.00 Copies, Per Sheet 0.15 MAIERIAL ENGINEERING / FIELD OBSERVATION SERVICES SERVICES RATE PER HOUR Principal Engineer $ 95.00 Project Engineer (Registered) 75.00 Staff Engineer 55.00 Supervising Laboratory/ Field Technician 48.00 Laboratory/Field Technician 47.00 Drafting 32.00 Typing, Clerical 30.00 Code Designated Deputy (Special) Inspector 50.00 a. Concrete Batch Plant b. Field Concrete c. Masonry d. Reinforcing Steel e. Pre -stressed Concrete f. Shop Welding g. Field Welding h. Structural Steel i. Field Gunite Non -Destructive Testing a. Ultrasonic 60.00 b. Magnetic Particle 60.00 c. Dye Penetrant 55.00 d. Pachometer/Schmidt Hammer 55.00 Observation Performed by Others Cost + 20%0 -3- • • MATERIAL ENGINEERING / FIELD OBSERVATION SERVICES (continued) SERVICES RATE PER HOUR Pick Up Test Sample $ 39.00 Premium Rates for Deputy (Special) Inspector a. Time and One -Half 68.00 (first 2 hours, Monday - Friday) b. Double . Time 86.00 (after 10 hours worked Monday - Friday and all hours on Saturday and Sunday) c. Union Holidays 122.00 (See Page 6 for detail) ADVANCE NOTICE: MINIMUM CHARGES: CANCELLATION: COMPLETION: TRAVEL TIME: MILEAGE CHARGE: SUBSISTENCE: PARKING: REGULAR TIME: OVERTIME RATE: CONDITIONS AND WORKING HOURS FOR DEPUTY (SPECIAL) INSPECTORS Twenty-four (24) hours advance notice required for scheduling inspector to report to designated job site. Show -up, no inspection performed 2 hours minimum 1 - 4 hours inspection performed 4 hours minimum Over 4 hours up to 8 hours worked, or required to work before 12:00 noon and work pass 12:00 noon 8 hours minimum No charge, if made before 4:00 pm of the preceding day. Inspector will remain on job until discharged by competent authority. No travel time will be charged, unless on remote jobs at the beginning and ending of the job. No mileage will be charged within 40 miles of our laboratory. For projects outside 40 miles and within 100 miles, mileage will be charged at the rate of $0.45 per mile. On remote jobs over 100 miles from our laboratory, subsistence, when not furnished for the inspector, will be charged at $70.00 per day, and mileage at $0.45 per mile for traveling to and from jobsite when free transportation is not provided. When not furnished for the inspector, parking will be charged as paid by the inspector. First 8 hours, Monday through Friday, between the hours of 6:00 am and 5:00 pm. (Time and one-half). First 2 hours outside regularly constituted shift or hours before 6:00 am and after 5:00 pm Monday through Friday. -5- DOUBLE TIME RATE: UNION HOLIDAYS: SHIFT DIFFERENTIAL: Second Shift: (Swing Shift) Third Shift: (Graveyard Shift) TERMS OF PAYMENT: All hours on Saturday and Sunday or non -union holidays on -site and all hours on union holidays off -site. Hours outside first 10 hours of constituted shift, Monday through Saturday. All hours (on -site work) on the following listed union holidays: 1. New Years Day 2. Memorial Day 3. Independence Day 4. Labor Day 5. Veteran's Day 6. Thanksgiving and the day after Thanksgiving 7. Christmas The first Saturday following the first Friday of the months of June and December Eight hours will be charged for first 7 1/2 hours worked. Time in excess of 7 1/2 hours will be charged at applicable overtime rate. Eight hours will be charge for first 7 hours worked. Time in excess of 7 hours will charge at applicable overtime rate. Net - Invoices are for Professional Services and arc due upon presentation. LABORATORY TESTING SERVICES A full range of laboratory testing equipment is provided for testing of soil, aggregate, concrete, masonry, asphalt, and other construction materials. Other services are also available upon request. Laboratory personnel consist of a Laboratory Director and trained Laboratory Technicians. The testing of materials is conducted with the use of calibrated laboratory equipment. All work is performed under the supervision of Registered Professional Engineers. • • ASTM Designation SOILS Rate Test L!nit per test Chemical Analysis Each Quotation D 2345 Consolidation Test Each $ 105.00 D 3080 Direct Shear Test Each 95.00 Expansion Test U B C Each 90.00 2.5" Diameter Specimen Each 65.00 Maximum Density - Optimum Moisture Determination D 1557 ASTM Each 90.00 Cal Impact Method (CAL 216) Each 100.00 D 422 Mechanical Analysis with Hydrometer Analysis Each 105.00 D 2216 Moisture Content Each 20.00 D 2434 Permeability Test (Complete) Each 175.00 D 4318 Plasticity Index (Plastic and Liquid Limit) Each 95.00 D 2844 R-Value Determination Natural Soil or Base Each 175.00 Lime or Cement Treated Soil Each Quotation D 2419 Sand Equivalent (CAL 217) Each 38.00 C 136 Sieve Analysis (Pit Run) Each 68.00 C 117 Sieve Analysis Washed on No. 200 Sieve (Processed Material) Each 48.00 D 1633 Soil Cement Molding and Compressive Strength Test (Set of 3 Specimens, 1 Cement Content) Each 315.00 D 560 Soil Cement Molding and Freeze - Thaw Test (Set of 3 Specimens, 1 Cement Content) Each 500.00 D 559 Soil Cement Molding and Wet - Dry Test (Set of 3 Specimens, 1 Cement Content) Each 500.00 D 854 Specific Gravity Each 75.00 D 2488 Visual Classification Each 18.00 AGGREGATES ASTM Rate Designation Test Unit per test C 131, C 535 Abrasion Resistance (L.A. Rattler)(CAL 211) Each $ 80.00 C 142 Clay Lumps and Friable Particles Each 53.00 Cleanness Value (CAL 227) Each 80.00 D 3744 Durability Index (CAL 229) Each 115.00 C 123 Lightweight Pieces Each 84.00 Percent of Flat / Elongated Pieces (CRD 119) Each 60.00 D 693 Percent of Crushed Particles (CAL 205) Each 60.00 C 566 Moisture Content Each 20.00 C 87 Mortar Making Properties of Fine Aggregate Each 315.00 C 40 Organic Impurties Each 40.00 C 136 Sieve Analysis, Pit Run Material Each 68.00 C 136 Sieve Analysis, Processed Coarse Each 34.00 C 117 Sieve Analysis, Fine, Washed Each 48.00 C 235 Soft Particles (Scratch Hardness) Each 50.00 C 88 Soundness Test, Sodium Sulfate Each 200.00 C 127 Specific Gravity and Absorption, Coarse Each 50.00 C 128 Specific Gravity and Absorption, Fine Each 75.00 D 1664 Film Stripping Test (CAL 302) Each 67.00 C 29 Unit Weight and Percent Voids Each 53.00 D 422 Percent of Clay, Hydrometer Method_ Each 105.00 Percent of Shale Each 50.00 C 289 Potential Alkali Reactivity, Chemical Method Each 175.00 C 295 Potential Alkali Reactivity, Petrographic Method Quotation C 227 Potential Alkali Reactivity, Mortar Bar Method Quotation —9— CONCRETE ASTM Rate Designation Test Unit per Test Concrete Mix Design (excl. Aggregate Test) Each $ 75.00 Review of Concrete Mix Design Each 75.00 C 192 Concrete Trial Mix (each mix) Equipment and Labor Each 180.00 Molding, Curing and Testing per Specimen 6" x 12" Cylinder Each 25.00 6" x 6" Flexural Beam Each 60.00 Special Curing Process C 684 Hot Water Curing (per specimen) Each 52.00 Rapid Curing, Boiling Water (per specimen) Each 90.00 C 39 Compressive Strength, Concrete Cylinder Each 15.00 C 42 Compressive Strength, Concrete Core Each 20.00 Compressive Strength, Gunite Cylinder Each 25.00 Compressive Strength, Gunite Core Each 20.00 Compressive Strength, Insulating Concrete Each 25.00 Core Trimming, (if needed) Each 23.00 C 1084 Cement Content (Chemical Method) Each 155.00 C 567 Dry Unit Weight, Lightweight Concrete Each 25.00 Dry Unit Weight of Insulating Concrete Each 30.00 C . 78 Flexural Strength, 6" x 6" Beam Each 40.00 Flexural Strength, 9" x 9" Beam Each 60.00 C 174 Length Measuring of Drilled Core Each 50.00 C 469 Modulus of Elasticity Each 90.00 C 157, C 341 Drying Shrinkage (set of 3, up to 28 days) Each 200.00 C 496 Splitting Tensile Test Each 32.00 C 642 Specific Gravity, Absorption, Voids in Hardened Each 200.00 Concrete (Set of 3) —10— MASONRY ASTM Rate Designation Test Unit per Test C 67 Brick Test (5 Specimens) 24—Hour Absorption, Cold Water Each $ 100.00 5— Hour Absorption, Boiling Water Each 125.00 Compression Test Each 125.00 Modulus of Rupture Each 125.00 C 140 Concrete Block Test (3 Specimens) Moisture Content and Absorption Each 120.00. Compression Test Each 105.00 Unit Weight (including Dimension Measurement) Each 75.00 C 426 Linear Drying Shrinkage (3 Specimens) Each 210.00 C 270 Mortar Mix Design (excl. Aggregate Test) Each 75.00 C 476 Grout Mix Design (excl. Aggregate Test) Each 75.00 C 109 Mortar Strength (2" cube or cylinder) Each 15.00 C 942 Grout Prism Test (3" x 3" x 6") Each 38.00 Trimming, included C 42 Masonry Core, Compression Test Each 25.00 Masonry Core, Shear Test Each 50.00 Masonry Core Trimming (if needed) Each 23.00 E 447 so ry 'sm Assemblage) 8" x 16" x 16" (Per Specimen) Each 125.00 12" x 16" x 16" (Per Specimen) Each 175.00 Larger than 12" x 16" x 16" Quotation —11— ASPHALT ASTM Designation Test Rate Unit per test D 1560, 1561 Asphalt Pavement Mix Design Quotation (Hveem Method) D 1559 Asphalt Pavement Mix Design Quotation (Marshall Method) D 2172 Asphalt Content by Extraction Each $ 140.00 Asphalt Content and Gradation by Extraction Each 190.00 D 1188, D 2726 Bulk Specific Gravity of Compacted Specimen Each 32.00 Centrifuge Kerosene Equivalent (CAL 303) Each 175.00 Moisture Vapor Susceptibility (CAL 307) Each 125.00 D 1559 Marshal Resistance to Plastic Flow Each 100.00 Marshal Maximum Density Each 75.00 D 1560 Hveem Stability Value by Stabilometer Each 100.00 (CAL 366) D 1561 Kneading Compacted Maximum Density Each 75.00 (CAL 304) C 128 Specific Gravity of Extracted Aggregates Each 75.00 Swell Test (CAL 305) Each 85.00 D 2041 Measured Maximum Theoretical Density Each 60.00 (Rice's Method) Calculated Maximum Theoretical Density Each 110.00 (with Aggregate Tests) D 113 Ductility of Bituminous Materials Each 55.00 D 5 Penetration of Bituminous Materials Each 40.00 D 36 Softening Point of Bituminous Materials . Each 75.00 D 71 Relative Density of Solid Pitch and Asphalt Each 40.00 D-3407 Resilience of Bituminous Materials Each 40.00 ASTM Designation STEEL Test Rate Unit per Test Reinforcing Steel Test; Tensile Strength amd Elongation #11 and smaller Each $ 30.00 #14 bar Each 60.00 #18 bar (Proof Test) Each 80.00 Bend Test, #11 and smaller Each 35.00 Structural Steel Test; Tensile Strength and Elongation Machining and Preparation of Test Specimen Cost + 20% Up to 200,000 pounds Each 30.00 200,000 - 300,000 pounds Each 60.00 300,000 - 400,000 pounds Each 80.00 Bend Test Each 35.00 Prestressing Wire and Tendon Test; A 421 Tensile Strength, Single Wire Each 50.00 A 416 Tensile Strength, 7-Wire Strand Each 85.00 A 325, A 490 Bolt and Nut, Proof Load Test Each 15.00 Shear Stud Test Each 40.00 Hardness Test Each 15.00 Bolt Tension Test Each 20.00 Welding Procedure Oualification; Groove Weld Each 350.00 Fillet Weld Each 250.00 Welding Specimen Test; Ultrasonic Examination Each 60.00 Machining and Preparation of Test Specimen Cost + 20% Macroctch Test (3 faces) Each 45.00 Reduced - Section, Tension Each 30.00 Bend Test Each 35.00 -13- Test Calibration of Hydraulic Ram 100 Ton and under 101 Ton - 200 Ton Laboratory Equipment Roof Materials MISCELLANEOUS Use of 60,000 pound Universal (with one operator) Use of 400,000 pound Baldwin (with one operator) Additional Technician (when required) Each Each Rate $ 100.00 120.00 Hour 90.00 Hour 180.00 Hour 47.00 New Roof Membrane (ASTM D 3617) Each 180.00 Built -Up Roof Assembly (ASTM D 2829) Each 250.00 Roof Tile (Breaking Strength & Absorption) Each 45.00 Spray -Applied Fire Proofing In -Place Density (ASTM E 605) Each 42.00 P V C Conduit (ASTM F 512) Stiffness Test (per specimen) Each 20.00 Impact Resistance (per specimen) Each 15.00 Flattening Test (per specimen) Each 20.00 Crushing Resistance (per specimen) Each 20.00 Verification of Dimensions Each 30.00 Coring (Concrete, Masonry, Gunite & AC Pavement) Equipment and Labor Hour 66.00 Bit Charge (per inch length of core) Each 2.00 Additional Technician Hour 47.00 By Others Cost + 20% -14- APR-09-1993 14:17 FROM • pnoouces THE JORDAN COMPANY 328 VIEW HOSPITALITY. #300 POST OFFICE BOX 82711 SAN BERNARDINO, CA 924124270 COCE 714 >sve CUP6 8115,12411 wows C.H.J. INCORPORATED POST OFFICE DOX231 COI_TON, CA 92334.0231 JORDAN COMPANY TO 3506618 P.01 NNOO R n PPONE MED AS TE HOLD R THIS CMEiMF� TE 00 O.S NNOTAME EXTEND OR ALTER NE OCVERAAE AFFORDED BY THE POLICIES BELOW . COMPANIES AFFORDNG COVIa GE ISTTIN A- Gamin wine mice comma, myna Yr B Fremont Corripormailoo Insurance celfAertenet C ..-.,..... ...... t•.,.., h. •1... ......:v, t?rm' �>, �ki ,fteyrro cna,?.• ::� � �4jt v�U ...'w 3 THIS •�.;;;:�;`~�Y:,��g ,,...:C..wmv'... '�:•`. �;t 13 TO CE 11FY THAT P DINIII /OUCt:S OF INSURANCE LISTED BELOW HAVE S TO THE INSURED NAMED ABOVE FOR THE POLICY PS INDICATED MAY OOUEO on MAYPEf�ITAyINryNY M,, �ET�H{ IN*URATERM C AFFOH CONDITIONOD OY HE OR OTHER DOCUMENT SUBJECT AL O 'TERNS E,XCIJWSIONB AND CONDITIONS OF SUCH PCIJCIES 19IAITS SHOWN MAY HAVE SEEN REDUCED BY PAID CLAIMS. 1 R; TYPE OF murmur (ImmomL uAeAnY x ; =NaEiIGIALa&MRAI.Maury • a cuL snrsuRsiwOsInww as.Paos. ' Xj AIRAUTO SCHI IAZD N.1101 A i.. x iiowow IEH Auras r : WANE LIANUTY POLICY NORM*~' PORGY MC= POLIO EEPOUT10N; ALL UIR,,L, Ieb CCP 5130 79 01/0118D CCP 2130 79 01 /01/93 CUM;iLL au1Y . 1 OTFIRRT osILIMINSUA• D i rue ? YIP �O1 arLtYNNY UNMAN ..�................... ........ «.«_..... _.._,..__..... ....- ...__.__...._._......... ..,............ q...................... PRIER RN Contract *WOW malls The city all Main% Na M_Ceod CIAIMs, dTSbIfs, atl10 IfpII 1Ly9Wl we Additional In. x+ed for geae■I LIablEy per form CO 20 10 11 95 an isysI$s, 1130 =EFT 10 for of Rent= CRy of Fantail Ann: Robert Vradc94e MN Sierra Avows Fontana, CA 98336 EN/ UTN M 01101/94 DINInYIL "°°"il°"`TE s ....?x... AooaEaAls; • 1i000, EACH Occunnoirx i sovonoor i 01/01/93 01/01/84 1z000, crvllalAmaslm • i, p00q, (01N11SCO•P000Y UNm +„ti. ,_laltoG#.+Y C.}O,rnerevir+r:hrfJrit?tthcr.carnwit/imrairmyrnri'A S, ,,... \. ly,,citA o• SHOULD ANY OF THE A8091E DESCRIED POLICIES BE CANCELLED BEFORE TM EXPIRATION DATE T141REOP. THE ISSUING COMPANY wiLLasslisPimoni MAL "' UATSWRITTEN NOTICE TO nsEGtH(IMAM HL71.Ut:HNAMW IU'1 LEFT, gq" ... .;-..'r-S..u/U•b�.r�,. u:u::n'3:�. s�1Xti:17�.sR.;;..h�RRub'3I .. .. .i:. ay 4 APR-09-1993 14:18 FROM JORDAN COMPANY TO 3506618 P.02 POLICY NUMBER: • COMMERCIAL GENERAL LIABILITY THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT CAREFULLY. ADDITIONAL INSURED OWNERS, LESSEES OR CONTRACTORS (FORM B) This endorsement modifies insurance provided under the following: COMMERCIAL GENERAL LIABILITY COVERAGE PART. SCHEDULE Name of Person or Organization: SEE FRONT OF CERTIFICATE (If no entry appears above. information required to complete this endorsement will be shown in the Declarations as applicable to this endorsement.) WHO IS AN INSURED (Section IF ) Is amended to include as an Insured the person or organization shown in the Schedule, but only with respect to liability arising out of "your work" far that insured by or for you. CG 2010 11 89 Copyright. Insurance Servictas Office. Inc.. 1984 TOTAL P.02 TO 3506618 P.01 it a Iu 3HOL7D ANY OP11•LE ABOVE D®CRIBF.D POLICIES BE CANCWED BEFORE THE EXPIRATION DAIS THEREOF. THE ISSUING COMPANY WILL: ENDF_AVOR TO t.PwrL •' DAYS WWTIIIII NUSLCb IL)'IMC CERTIFICATE HOLDER NAMED TO TH LEFT. Bt.rr FAILURE TO MAIL SUCH NOTICE SHALL IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON THE COMPANY. TIS AGENTS OR R1p1t8St1NTA1VdES. THE JORDAN COMPANY 325 WEST HOSPITALITY, 8300 POST OFFICE BOX 5276 - SA1Y BERNARDINO,CA• 92412.5276 ISiURDATE GA 03/h.S/93 THIS CERTIFICATE IS ISSUED AS A CHATTER OF INFORMATION ONLY AND CONFERS NG R1( TI UPON THE CL11iI1BCATO HOLDER_ THIS CERTIFICATE DOES NOT At NT EXTEND OR ALTER THE COVERAGE APR RDED BY MS POLICIES BELOW • COMPANIES AFFORDING COVERAGE i mMPAHY Lerr e A Golden Eagle Insurance Company cams slowORt ., $$1F2231 ......CO1rvANY .._.- 714.. ....._._._...... ........__....,._...._._...._._............_.... U�Idtt� �p B Fremont Compensation hlatlrancc C.iI.J. INCORPORATED POST OFFICE BOX23I COLTON, CA 92324-0231 w7✓) .:...:?. •, " iGrwo < S �cw .+^„w^ J T w.« «te r° "1� 4,• -ME •STar • THIS I3 TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN11 UED TO THE INSURED NAMED ABOYE FOR THE POUCY PER101. INDICATED. P1d11VITFLSTANDING ANY RBODUUDMFa:1, TERM OR CO:4DTRON OF ANY CONTRACT OR OTHER DOCUISENT WITH EBRP5GT TO WI4IC11 fl(I WICATE MAY BE ISSUED OR MAY PlutiArN. THE DNSURANCE A)•la0RDED BY,7RE POUC1Cs DOICR1BED HEREIN 13 3I(B1l L I tU ALL THS TERMS, VOWS AND CONDITIONS OP SUCH POUCIE3. LIMITS SHOWN MAY HA BEEN REDUCED BY PAID CLAIMS. • L S TYT6o11rMURANCE : CINA ALLIAgM= .X WiO t.G>u'ctauABB1fY Mg i curt IdAD6 ..... acwa.: x ; awl+lBe'sa cacras hits pkor. i • AUTomo LI Id UIS-11T �(! ANY AUTO t...•.•.. ALL OWNSDAVM '.......y SCH6btfmAUIDi X s 3iQlBDAUTOi ..xi NOWOWNEDAUTOS GARAGE LIALItUr r PRXMILIAtiLtarY WORKERMOOXPEPRIATKEI AND IIMPLOYEILIP LPAE1Lti'Y Wan 1OLUCY NUMEER POLICY E . ^ IYi; POLICY ItEPIRATION PATE 1 i OATS devaOIT1ry CCP 2130 79 CCP213079 WP 93-552922-01 01/01/93 LIMITS IN TIIO4$Arms OSIERAL AGGREGATE i 2.000, : F LooGgIsCOIGYGP3 AGGRECAT5 : i 1,000, • _.. _ 01/0I/94 i PEIIRONAL st AOYNITISEIC MOW . t 1,000, 01/01/93 �01/01/94 �O1/01/93 01/01/94 OfZ>citie'[411o1olit< cynneI ncso.'TTWR Re: Cotlttact Soviets Additional hraulad for enteral .L ab lii1y per form CG 20 10 11 115 on rovers*. **30 Da EXCEPT 10 Da for Non -Pa of Pram' ekaoccuamosce ruts nA .V.GE IAacue fircl s 1,0, i 50, MEDICAL EX 5 NMEIN , t.natr EGIAL IWUttY a'a meow BOINLY INJURY $ . .°aee.1Dawns M yw . E 4�s N inert roar wdH.,<M W7141v.. gyp»'i.w•.n • i 1 1 1,000. i • AGGREGATE OCCURRENCE i i • 1.000.� ACCID> III ............... I,000, mnsuar1.Pot.ICY.uaiu 1.000. auseascs.EACU F0MP1AYi(E, ,,. yk• :.r. e < 1. .4L.t �'.., .�..'^� _ wS st.wwati•--z ;l.ti:.«ao>a+ .; ih+•n.•.•--•-^ •� ,I J! f•° r_ i°�. �� 1.... '.. . .�'., �:. .'SiS :G^ .. .....x .. �.i !. Y! S a' .. .. - _. AP76A1W w'K.* «* .Pao a .:4:Ac y , w City of Fontana Attn: Mr. Weddle Post Of&oa Boa 518 Foote" CA 92335 .l.kGZ�iT.._ . i`.M�.: 11" �°� 1.1 '1 oIs;n'C;: MAR-24-1993 19:31 FROM JORDAN COMPANY POLICY NUMBER: TO • 3506618 P.02 COMMERCIAL GENERAL LIABILITY THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT CAREFULLY. ADDITIONAL INSURED - OWNERS, LESSEES OR CONTRACTORS (FORM B) This endorsement modifies insurance provided under the following: COMMERCIAL GENERAL LIABILITY COVERAGE PART. SCHEDULE Name of Person or Organization: SEE FRONT OF CERTIFICATE (If no entry appears above, information required to complete this endorsement will be shown in the Declarations as applicable to this endorsement.) WHO IS AN INSURED (Section II) is amended to inck,de'as an insured the person or organization shown in the Schedule. but only with respect to liability arising outof "your work" for that insured byor for you. s CC 2010 1185 Copyright. Insurance Services Office. Inc.. 1984 y TOTAL P.02 ,R -24 -1993 /9:29 .TORDAN COMPANY TO 3506618 P.01 PERDU= •-• • • .... 11 ;14 3 •-,-2•4i ISSLIIKDATff • . fr. • --• ":•,•••.%.f4-•••••"^"i.=V:4•14,-••-"t„. 1"::tv!t•• • " ' . , • 4-Pc.- 1. 03/2S/93 THE JORDAN COMPANY 325 WEST HOSPITALITY, a* POST OFFICE BOX 5276 SAN BERNARDINO,'CA 92412-5276 THIS CERTIFICATE 1.9 MED AS A MATTER OF INFORMATION ONLY AND CONFERS NO MGM UPON ME CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEN1 =END OR ALTER THE COVERAGE AFFORDED BY ME POLICIES BELOW coMPANT urrnm A CODE 8SOLCODE • ' 714 S88-2231 COMPANY DIitSD ... . INCORPORATED POST OFFICE BOX231 covros, CA 9232442.31 • 13 • - , • ‘11.1 , .. • ...... COMPANY LEITER C cosmANT sarrsa D COMPANT LETTIM COMPANIES AFFORDING COVERAGE Golden Eagle Insntancc Company Fremont Compensation Insure/me This IS TO CUTTER TEAT THE POLICIES OF D:SURANCE LISTED BELOW HAVE BEEN ISSUED• THE INSURED NAMED ABOVE FOR THE POLICY PERO/ INDICATSD, NOMITISTANDING ANY RBQIIIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT wrns RESPECT TO WHICH n/ CERTIMATE MAY REISSUED OR MAY PPRTATN. THE INSURANCE AFSORDED By inn mums DzscgmeD Hem,.sum tAa iv Au. THE TER?". INCLUSIONS AND CONDITIONS OP SUCH POUctss. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. Coi LTS IOLICY NUMBER me osinaLMANCa • •' . ' t• . i i MIRA& ZIASUAT . . 1 I XI CITIOIERMAL GINEIMLLIABILITY . nt X I CLAIM ISADq !, OCCUR. i .61;;...)c j owNErs a aH471Aiiiii Plat. 1. ..... .. CCP 21 30 79 AVIDSIOBILE LMMMTT i X ANY AUTO ..... ALL owes') MHOS L. SCHIEREEDAITILIg A x HIRED AUTO& x eors-owsom Ammo .... GARAGE LOMAT' 1--*---4 i i ! 1 ! sacasaskususw ,' ! • .--••- •-••••- , . i OTHER IllAN UMBEILIA sous /, ; , .i... .... —........ . ....... .". ... .... ....... . i i 01/01/93 ' 01/01194 CCP 21 30 79 ,1 : Pal (49811SYYY) 11;4'4411 (MMAID/TY) GENERAL AGGREGATE S • 2.000, PloaucrsoMumes AGGREGAT,i' ; 1,000, if PERSONAL AnvERTISMG INEEt, Y .t 1,000. POLICY arTICTIVS; rULICY IDIFIRATION ALL LIMITS IN 0 I 101193 01 /0 1 /94 01/01/93 01/01/94 WOREERM COMMEMINTIQP, AIS DeLoyster umustry WP 93-557.922-01 f fan* raweargaulartim ft Comm( Services Additional Insured for Grocralllabipty per form CG 20 10 11 115 on Tvvene. *0130 Da EXCEPt 10 Da s for Non -Pa of Preini 1. •••• City of Moues Mn: Mr. Weddle Post Office BOA 518 Pomo., CA 92335 ---,T.:LI I.A.4.1....'11.-.7.7i.:;•.1'•.:"...' ..f.7"4',.;'';':.!;1. :,1 .....w ... ..„....4 - - I/ wpm) ANY OP IME ABOVE DESCRIBED POLICIES BE CANCEIJ ED BEFORE THE EXPIRATION DATE THEREOF. MB ISSUING COMPANY WILL ENDEAVOR TO meat. ** DAYS wRITTIsI4 DIGS 10 'DM CERTIFICATE HOLDER NAMED TO mr. LEFT. BUT FAILURE TO MAIL. SUCH NOTICE SHALL IMPOSE NO OBLIGATION OR LIABILITY OF ANY RIND UPON THE COMPANY. rr$ AGENTS OR PDPREsBNYATIvEl; 4xt: tnt ;sz COMBINED ENGLE MUT MOLY IMRY Myr mom sooax .1 INJURY/ $ . (Per wade.) IlEireltTY . $ OCCURRENCE 8 i g • • SACD OCCURRENCE FIRE DAMAGE (Any am 1;14 $ LOCO, SO MEDICAL EX PENN tAki; at mono I5, EXt4AM, L000. ,11r4-Mgte,.. 5- - &ft,=.4,z- • AGGREGATE "Annuity :172.:11r Loop, MACE ACCIOVID 1,000, ERSEASESPOLICY UAW) 400. (f.MSEASIMEACIA Paplornito AMMO, Awes r. : . . - • . • - . • N. A MAR /24-1993 19:31 FROM JORDAN COMPANY TO 3506618 P.02 ' POLICY NUMBER: COMMERCIAL GENERAL LIABILITY THIS ENDORSEMENT CHANGES THE POLICY. 'PLEASE READ IT CAREFULLY. ADDITIONAL INSURED w- OWNERS, LESSEES OR CONTRACTORS (FORM B) This endorsement modifies insurance provided under the following: COMMERCIAL GENERAL LIABILITY COVERAGE PART, SCHEIKJLE Name of Person or Organization: SEE FRONT OF CERTIFICATE F (If no entry appears above, information required to complete'this endorsement will be shown in the%Dectarations as applicable to this endorsement.) WHO IS AN INSURED (Section II) is amended to include as an insured the person or organization shown in the Schedule. but only with respect to liability arising out of "your work" for that insured by opfor you. CC 2010 11 85 Copyright. Insurance Services Ottice. Inc.. 1984 TOTAL P.02 CITY OF FONTANA CALIFORNIA MEMORANDUM TO: Bob Weddle, City Engineer FROM: Robert A Graham, Risk Management Consultant SUBJECT: Baseline/Almeria Sewer Project CHJ Inc. Consultant Contract for GeotechnicalServices DATE: April 28, 1993 The certicate of insurance provided by CHJ Inc. dated 3-25-93 (Policy #CCP 21 30 79 and WP 93-552922-01) complies with the City Attorney's opinion as stated in his letter of April 7, 1993 on the above contract. If you have any further questions, please call me at 350-6683. RAG/sm NAME: CALIF ORN FAX COMMUNICATIONS FROM FAX NUMBER: (714) 350- 6618. PLEASE DELIVER THE FOLLOWING PAGES TO: l o,sEe_r T. -52-Nso o LOCATION / PHONE: (J-') 2-4 '12_I O FAX NUMBER: (3 I1-I) KZ 4-7 ZO FROM: Yd t&S.44 F 1' — w t.ik LOCATION / PHONE: (ocj) 3S b _ 6, G ti r ACCOUNT NUMBER: i TOTAL NUMBER OF PAGES: 14- 4 DATE: 4-1-93 TIME: 9 : So 1444. (including cover sheet) IF YOU DO NOT RECEIVE ALL OF THE PAGES, PLEASE CALL (714) MESSAGE: PLEASE. -tom t 05.444-n1c-F GF,T i(kTE, klub FntDorSC-.M ENT 4kS REgU tK.ED Eli. eirr ,ATTDR-NEYs OFF I c-E . P i M E c -L me_ i P- y i+ H*11E THE r; �(EST (0k S . I �1-9t i fia . 8353 SIERRA AVENUE P.O..BOX 518 FONTANA, CALIFORNIA 92334-0518 PHONE NUMBER (714) 350-7600 DEC.1990 SKY- BEST, BEST & KRIEGER ° A PARTNERSHIP INCLUDING PROFESSIONAL CORPORATIONS LAWYERS ARTHUR L. LITTLE WORTH* GLEN E. STEPHENS* WILLIAM R. DeWOLFE* BARTON C. GAUT* PAUL T. SELZER* DAVID L. BARON DALLAS HOLMES* EUGENE TANAKA CHRISTOPHER L. CARPENTER* BASIL T. CHAPMAN RICHARD T. ANDERSON* TIMOTHY M. CONNOR JOHN D. WAHLIN* MICHAEL D. HARRIS* W. CURT EALY* THOMAS S. SLOVAK* JOHN E. BROWN* MICHAEL T. RIDDELL* MEREDITH A. JURY* MICHAEL GRANT* FRANCIS J. BAUM* ANNE T. THOMAS* D. MARTIN NETHERY* GEORGE M. REYES WILLIAM W. FLOYD, JR. MICHAEL A. CRISTE* GREGORY L. HARDKE KENDALL H. MacVEY CLARK H. ALSOP* DAVID J. ERWIN* MICHAEL J. ANDELSON* * A PROFESSIONAL CORPORATION DOUGLAS S. PHILLIPS* ANTONIA GRAPHOS GREGORY K. WILKINSON WYNNE S. FURTH VICTOR L. WOLF . DANIEL E. OLIVIER DANIEL J. McHUGH HOWARD B. GOLDS STEPHEN P. DEITSCH MARC E. EMPEY JOHN R. ROTTSCHAEFER MARTIN A. MUELLER J. MICHAEL SUMMEROUR VICTORIA N. KING JEFFERY J. CRANDALL SCOTT C. SMITH JACK B. CLARKE, JR. BRIAN M. LEWIS JEANNETTE A. PETERSON BRADLEY E. NEUFELD KANDY LEE ALLEN ELISE K. TRAYNUM WILLIAM D. DAHLING, JR. Mr. Robert Weddle City Engineer City of Fontana 8353 Sierra Avenue Fontana, CA 92335 Dear Bob: MATT H. MORRIS JEFFREY V. DUNN STEVEN C. DeBAUN BRANT H. DVEIRIN ERIC L. GARNER DENNIS M. COTA JULIE HAYWARD BIGGS RACHELLE J. NICOLLE ROBERT W. HARGREAVES JANICE L. WEIS SHARYL WALKER PATRICK W. PEARCE KIRK W. SMITH JASON D. DABAREINER KYLE A. SNOW MARK A. EASTER DIANE L. FINLEY MICHELLE OUELLETTE PETER M. BARMACK DAVID P. PHIPPEN, SR. KENNETH R. WEISS SUSAN C. NAUSS CHRISTOPHER DODSON BERNIE L. WILLIAMSON ELAINE E. HILL KEVIN K. RANDOLPH JAMES B. GILPIN MARSHALL S. RUDOLPH KIM A. BYRENS CYNTHIA M. GERMANO MARY E. GILSTRAP NGUYEN D. PHAN DANIEL C. PARKER, JR. GINEVRA C. MARUM CHARLES E. KOLLER GLENN P. SABINE CHRISTINE L. RICHARDSON JOANE GARCIA-COLSON PHILIP J. KOEHLER DIANE C. WIESE STEVEN S. KAUFHOLD REBECCA MARES DURNEY ALLISON C. HARGRAVE DOROTHY I. ANDERSON G. HENRY WELLES JAMES R. HARPER DINA O. HARRIS RAYMOND BEST (1868-1957) JAMES H. KRIEGER (1913-1975) EUGENE BEST (1893-19811 April 7, 1993 REC'� EIr CITY ENGINEER'S OFFICE ` T' SUITE 120 800 NORTH HAVEN POST OFFICE BOX 4360 ONTARIO, CALIFORNIA 91761 TELEPHONE (714) 989-8584 TELECOPIER (714) 944-1441 Re: BASELINE/ALMERIA SEWER PROJECT CHJ, Inc. Consultant Contract for Geotechnical Services OF COUNSEL JAMES B. CORISON OFFICES IN RIVERSIDE (714)686-1450 PALM SPRINGS (619)325-7264 RANCHO MIRAGE (619)568-2611 You have requested that the City Attorney's office sign off on the enclosed contract between the City and CHJ, Inc. for geotechnical services related to the Baseline/Almeria Sewer Project. Please note that the Certificate of Insurance provided by CHJ, Inc. does not meet the terms of the Agreement and consequently is not sufficient. Specifically, the Agreement (see Section II, paragraph 10) requires that the "City, its elected officials, officers, and employees" be added as insureds. The Insurance Certificate that has been provided apparently fails to do this. In addition, the Agreement requires that the insurance policy shall be endorsed to state that coverage may not be cancelled unless 30 days prior notice has been given in writing to the City. Given that requirement the language at the bottom of the Certificate which requires the insuring company to "endeavor to mail written notice" to the City some unspecified number of days in advance of cancellation is not adequate. CHJ, Inc. should provide DBB25934 14.4 1-‘ '4, (5-** ))t.i' /3.4, 6 (44,754 . P2,ilt- LAW OFFICES OF • • BEST, BEST & KRIEGER Robert Weddle, City Engineer April 7, 1993 Page 2 the City with a Certificate which states that their insurer is required to give notice to the City by mail 30 days in advance of any policy cancellation. The language at the bottom of the Certificate stating "failure to mail such notice shall impose no obligation or liability of any kind upon the company, its agents or representatives" should be eliminated. This Agreement also differs from the current Model Consultant Agreement used by the City in that it only requires Best's Class B insurance (currently the City requires Best B+VIII) and it does not include indemnification for omissions of the Consultant. You have indicated that at the time the project was put out to bid, the terms required by the City were those included in this Agreement, and based upon that representation I have signed the contract and approve its use for this project. However, the Certificate of Insurance should be corrected prior to having the City Manager sign on behalf of the City. Sincerely, Stephen P. Deitsch BEST, BEST & KRIEGER City Attorney cc: Jay M. Corey, City Manager Ken Jeske, Interim Director of Community Development Clark H. Alsop, City Attorney DBB25934 REPORT OF GEOTECHNICAL INVESTIGAtION TENTATIVE TRACT 12314 BASELINE ROAD NEAR CITRUS AVENUE FONTANA, CALIFORNIA \, - . .0,-Erl :"..4. X ,......*Ajg .91 . . REPORT OF GEOTECHNICAL INVESTIGAtION TENTATIVE TRACT 12314 BASELINE ROAD NEAR CITRUS AVENUE FONTANA, CALIFORNIA \t SUBMITTED TO: PRESLEY OF SOUTHERN CALIFORNIA P. 0. BOX 19672 IRVINE,'CALIFORNIA 92713. PREPARED BY: Soil and Testing Engineers, Inc. 167 W. Orangethorpe Placentia, California 92670 r. C SOIL and TESTING ENGINEERS INC. • ORANGE COUNTY 167 W. ORANGETHORPE ■ PLACENTIA, CAUFORNIA 92670 ■ (714) 524-9130 0 COACHELLA VALLEY 74-831 VEUE WAY ■ PALM DESERT, CAUFORNIA 92260 ■ (619) 346-5012 0 SAN BERNARDINO 1894 COMMEFICENTER WEST, SUITE 305 • SAN BERNARDINO, CAUFORNIA 92408 • (714) 381-3528 July 14, 1987 Presley of Southern California P. 0. Box 19672 Irvine, California 92713 STE 8741089 Report No. 1 Subject: Report of Geotechnical Investigation, Tentative Tract 12314, Baseline Road Near Citrus Avenue, Fontana, California. Gentlemen: In accordance with your request, we have completed a geotechnical investigation for the proposed project. We are presenting herein our findings and recommendations. The findings of this study indicate that the -site is - suitable for the proposed development provided the --recommendations presented in the attached report are complied with. If you have any questions after reviewing the findings and recommendations contained in the attached report, please do not hesitate to contact this office. This opportunity to be of professional service is sincerely appreciated. Respectfully submitted, SOIL A;' TESTING ENGINEERS, INC. Rom rt J. Staff Engi A. Har'tey Reviewed by: CEG #1098 "Robert R. Russell RCE #32142 RJN/RRR/AHJ/jd cc: (6) Submitted TABLE OF CONTENTS. PAGE INTRODUCTION AND PROJECT DESCRIPTION 1 PROJECT SCOPE 1 -FINDINGS 2 - SITE DESCRIPTION 2 GENERAL GEOLOGY AND SUBSURFACE CONDITIONS 3 GEOLOGIC SETTING 3 SOIL DESCRIPTION 3 GROUNDWATER 4 4 4 TECTONIC SETTING SEISMICITY RECOMMENDATIONS AND CONCLUSIONS 5 GENERAL DESIGN CONSIDERATIONS 5 DEMOLITION 6 HARD CONSTRUCTION DEBRIS AND DELETERIOUS MATERIALS 6 ABANDONED UTILITIES 6 TREE REMOVAL . . . - 6 SEEPAGE PITS 6 SITE PREPARATION 7 REMEDIAL GRADING 7 STREET AREAS AND CONCRETE FLATWORK 7 FILL AREAS . 7 IMPORTFILL . . . . . . . . . . . . • . . . . 7 SURFACE DRAINAGE - 7 EARTHWORK SHRINKAGE AND. SUBSIDENCE FACTORS . . . 8 EARTHWORK 8 FOUNDATIONS 8 GENERAL 8 LATERAL RESISTANCE 9 SETTLEMENT CHARACTERISTICS 9 EXPANSIVE CHARACTERISTICS 9 SOLUBLE SULFATES 9 LIMITATIONS 9 FIELD EXPLORATION 12 LABORATORY TESTING PROGRAM. . 13 FIGURE 1 PLATE 1 PLATE 2 ATTACHMENTS SITE PLAN PLOT PLAN UNIFIED SOIL CLASSIFICATION CHART PLATES 3 THROUGH 22 - TRENCH LOGS PLATE 23 DIRECT SHEAR TEST AND COMPACTION TEST, PLATE 24 GRAIN SIZE ANALYSIS .PLATE 25 SOLUBLE SULFATE TEST APPENDIX RECOMMENDED GRADING SPECIFICATIONS- SPECIAL PROVISIONS SOIL and TESTING ENGINEERS INC. ■ ORANGE COUNTY 167 W. ORANGETHORPE ■ PLACENTIA, CAUFORNIA 92670 ■ (714) 524-9130 O COACHELLA VALLEY 74-831 VEUE WAY ■ PALM DESERT, CAUFORNIA 92260 ■ (619] 346-5012 ❑ SAN BERNARDINO 1894 COMMERCENTER WEST, SUITE 305 ■ SAN BERNARDINO, CAUFORNIA 92408 ■ [714) 381-3528 - GEOTECHNICAL INVESTIGATION TENTATIVE TRACT 12314 BASELINE ROAD NEAR CITRUS AVENUE FONTANA, CALIFORNIA INTRODUCTION AND PROJECT. DESCRIPTION This report presents the results of our geotechnical investigation for a proposed residential subdivision which is to be located north of Baseline Road and approximately 1300 feet west of Citrus Avenue in the City of Fontana, California. It is our understanding that 259 single family, detached residences along with associated street improvements are planned for this site. It , is further understood that some grading will be _necessary to develop the site. This assumption was based upon our review of the existing topography. The site configuration and exploration locations are shown on Plate No. 1. The following Figure No. 1 provides a vicinity map for this project. PROJECT SCOPE This investigation consisted of: surface reconnaissance, subsurface explorations, obtaining representative samples, laboratory testing, analysis of the field and laboratory data, research of available geologic literature pertaining to the site, and preparation of this report. Specifically, the intent of our analysis was to: C i � I 4 I- VAIt NC:A AV 'I ---�vAtE.C,A £I__ __I 1 oresar—' 1 >s_t GE CT I d�r,wWR um BASE BASE R 3f.1 LINE aA.. J' •• A_ A AV Mlrap AY I Qr G'1 .. i.. �9 . KAM " 1 b fALZ a E d I< • .ST AY I ...Kw. AY I �! rAMM t qyl • Tw A)u g., Y. mA Ihl ' AT M $T AV V t } Pa1 ���fu�^''^ R t :i i i limos N 1 t 4ALAGA riL_ Cam« /NW AD . . IAA W .1 1Yf.f1. i '?T- tYM(ff I C �...`..`�.'�� r 1 ... rsalipl— �A1n�i rAK vILLy11115 I ST I `,�r•T°Li , DR ... �K 1a�REED;STL R$O 11 G n 1 i AT 1( Q PASSE f ST . IOC .. 1N/ +---!...! +- — Oa ST——— i—i — —i_ —U 1 Srr ►AWE i tl FOOTHILL y BIfV� IL/oo FQQT},tIL - torE a ST • rfoY.r[ IvIg1E ST n f 4 v j; 3. m Y ,..._ty_ p a ; C M I � wY III I 8 I taw SLYAL[ AV I ii • -+ w, I S _ vrm •a AV rorTAn I 'j✓ 1t SOR,Nf. L .r. (At AT M S T +— r—1T--.7.t = --444-----?r—S'— �� �� w a;> w152 a 2 9 8 W CO f, 3 i AV . I.. WOO —1-- aI cros .. CERES ORANGE SAN B RNARDIt•O SOIL and TESTING ARASTASIA SL i DIANTHUS .AV iAEVNLFA ST O(OOAR AV SITE VICINITY NAP ENGINEERS INC. Isr RN S7410$* JOB NUMBER: *NANO 1 ST n F 4 5 F I 1 `* -rrrtm 1 - '1 W11.ZARITA n ZAN TA TULLOCK j2i. El — AV DATE: S / 2 3 7 FIgur• N•. 1 STE 8741089 July 14, 1987 Page 2 Explore the subsurface conditions to the depths influenced by the proposed construction. b) Evaluate, by laboratory tests, the pertinent engineering properties of the various strata which will influence the development, including their bearing capacities, expansive characteristics and settlement potential. c) Define the general geology at the site, including possible geologic hazards which could have an effect on the site development. d) _Develop soil engineering criteria for site grading. e) Determine potential construction difficulties and provide recommendations concerning these problems.__ -- f) ,Recommend an appropriate foundation system for the type of structure anticipated and develop soil engineering criteria for the recommended foundation design. FINDINGS SITE DESCRIPTION The subject site is an irregular shaped parcel of land approximately 56.3 acres in size, located adjacent to Baseline Road approximately 1300 feet west of Citrus Avenue, in the City of Fontana, California. The site is bounded by vacant land on the north, east and west. In addition, an egg ranch was observed adjacent to the southwest corner of the site and tract homes were noted C STE 8741089 July 14, 1987 Page 3 adjacent to Almeria Street, north of the site. The site grades downward between 1% and 4% toward the. -south -- Average grade is approximately 2% and total relief is on the order of 50 feet. Drainage is accomplished by sheetflow to the south and natural percolation. Small artificial berms were noted adjacent to the egg ranch and also along the western perimeter of the site. Vegetation consisted of a dense growth of grasses and a few scattered trees. Rows of eucalyptus trees were also observed along Baseline Road, adjacent to the egg ranch, along the southern half of the western perimeter and through the central portion of the site (east -west trending). Old foundations were encountered within the central portion -of the site. A minor amount of broken concrete, asphalt and other debris was also _noted_invarious locations throughout the site. GENERAL GEOLOGY AND SUBSURFACE CONDITIONS GEOLOGIC SETTING: In general, the Fontana area is underlain by coarse grained, unconsolidated alluvialfan deposits, that radiate from the San Gabriel and San Bernardino Mountain fronts. Approximately 900 feet of these deposits are reported to underlie the subject site (CDMG SP113). Lytle Creek Wash and Cajon Wash lie north of the site and have prehistorically produced the sediments deposited in the area. Crystalline bedrock underlies the site at depth. SOIL DESCRIPTION: The near surface soils encounteredin. our exploratory trenches include prehistoric flood plain deposits that generally consist of silty sands, gravelly sands and sandy gravels. These soils were generally dry to humid and loose to medium dense in consistency to a depth of approximately five feet below grade. Below this depth STE 8741089 July 14,-1987 Page 4 the consistency and moisture content .increased. A more detailed description of the soils encountered are presented on Plate Nos. 3 through 22. GROUNDWATER: No groundwater was encountered within 12 feet of existing grade and no groundwater related problems are anticipated either during orafter construction. Groundwater is reported to be at a depth in excess of 500 feet below existing grade (CDMG SP113). TECTONIC SETTING: The site lies approximately 5 1/4 miles southwest of the San Jacinto Fault Zone and approximately 31 miles southeast of the Cucamonga Fault Zone. The San Andreas Fault Zone lies approximately 8.1/4 miles northeast of the site. The Fontana Fault lies approximately 11miles south of the site and has_ been inferred through seismic activity. An unnamed inferred .fault —line lies ___approximately one mile northeast of the site and has been mapped through groundwater studies (CDMG SP113). SEISMICITY: The proposed site is within the seismic ;Influence of four active faults. Considering the distance ..of the site from these fault zones; and the maximum probable magnitude associated with them, the following tabulation is obtained: 0 Fault Zone San Andreas San Jacinto Cucamonga Fontana Probable* Site Distance Magnitude (miles) (Richter) *From 8 1/4± 5 1/4± 3.5± 1.5± 8.1 7.0 6.5 5.9 Probable Peak Bedrock Acceleration (g's) 0.47 0.37 0.33 0.26 U.S.G.S. Professional Paper 1360. STE 8741089 July 14, 1987 Page 5 Of the zones listed above, the San Andreas or the San Jacinto Fault Zones are considered to be the zones in which a seismic event might be expected_ to. _cause__the__ greatest groundshaking on the site. Groundshaking resulting from -seismic activity along other major fault zones in the region is anticipated to be equal or less than that felt by the activity on the San Andreas or the San -Jacinto Fault Zones. It should be recognized that the Southern California region is an area of moderate to high seismic risk and that it is not considered feasible to make structures totally resistant to seismic -related hazards. The design acceleration should be determined by the structural consultant, and be reflective of the type of structure proposed. Due _ to the - geologic __and: -geomorphic ---setting of the site, other potential geologic hazards such as tsunamis, seiches, liquefaction, or landslides should be considered to be negligible or nonexistent. RECOMMENDATIONS AND CONCLUSIONS GENERAL DESIGN CONSIDERATIONS 'Based on the findings of this study, it is our opinion that the site is suitable, with respect to geotechnical factors, for the proposed development provided the recommendations presented in this report are followed. Items which will require special consideration are the existence of end dumped debris, old structures and associated subsurface utilities and loose surface soils. Recommendations to mitigate these conditions are presented in the following sections of this report. Any unusual or unforseen e. STE 8741089 July 14, 1987 Page 6 condition encountered during site development should be brought to our immediate attention. DEMOLITION HARD CONSTRUCTION DEBRIS AND DELETERIOUS MATERIALS: We recommend that all hard construction debris and deleterious materials resulting from the clearing and grubbing operations be legally disposed of off -site. All existing end -dumped materials should also be removed. ABANDONED UTILITIES: All existing underground utilities which are to be abandoned should be properly capped off and removed. The depressions resulting from these removals should be backfilled with compacted soil densified to at least 90% relative compaction. TREE REMOVAL: Removal of Pxtsting trees —should _alsa include the removal of their stumps and root balls. Root balls may extend up to 5 feet below grade and could result in a considerable amount of disturbed soil. --We recommend that all disturbed -soils be removed and the cavity resulting from these removals be backfilled with properly compacted soil. SEEPAGE PITS: Although not encountered, it is possible that old seepage pits may exist on -site. If encountered, we recommend that they be pumped out and be backfilled with a 3/4 inch crushed rock. These pits should then be cut off at least 5 feet below finished grade and covered with a 12 inch thick concrete cap reinforced with No. 3 bars at 12 inches on centers, each way. C STE 8741089 SITE PREPARATION July 14, 1987 Page 7 ;;!".REMEDIAL GRADING:. We recommend that all existing soils be `excavated to a depth at least 3 feet below existing grade or 2 feet below proposed footing elevations, whichever is greater. The exposed natural ground should then be watered to at least 3% above optimum to a depth of 18 inches. The soils should then be densified to a minimum of 90% relative compaction. The previously removedsoils may then be replaced in eight inch lifts, moisture treated to at least 2% above optimum, and compacted to a minimum of 90% of maximum dry density. The horizontal limits of the recommendations should include the area within a perimeter of 5 feet outside of each proposed structure. STREET AREAS AND -CONCRETE FLATWORR: The subgrade soils beneath all areas to support streets and concrete flatwork (driveways, patios, etc) should be moisture treated .to. -at least 2% above optimum and compacted to at least 90%. This moisture conditioning and densification should extend to a minimum depth of 24 inches. FILL AREAS: Areas to support fill soils, not covered by the previous sections, should be moisture treated and compacted to at least 90% to a depth of 12 inches. IMPORT FILL: Any proposed import fill should be non - expansive, have strength parameters equal to or greater than the on -site soils, and be approved by this office prior to its use. SURFACE DRAINAGE: We recommend that all surface drainage be directed away from the proposed structures and that ponding of water not be allowed adjacent to their foundations. STE 8-741089 L EARTHWORK SHRINKAGE AND SUBSIDENCE FACTORS: We anticipate- -- that shrinkage losses of approximately l0% can be expected July 14, 1987 Page 8 at this site during grading. We further estimate that subsidence of natural ground will be on the order of 0.15 foot. It should be recognized that these values are estimates only and should not be used as abasis for pay. Provisions for adjustment of grades should be made should a balanced job be required. EARTHWORK: All earthwork and grading contemplated for site preparation should be accomplished in accordance with the attached Recommended Grading Specifications and Special Provisions. All special site preparation recommendations presented in the_sections.above will__supersede those in the standard Recommended Grading Specifications.. All embankments, structural -fill, and fill should -be compacted to a minimum of 90% at slightly over optimum moisture content. Utility trench backfill within 5 feet of the proposed structure and beneath asphalt pavements should be compacted to at least 90% of its maximum dry density.. The maximum dry density of each soil type should be determined in accordance with ASTM D-1557, Method A or C. `FOUNDATIONS GENERAL: It is our opinion that the proposed structure may be supported by "conventional" spread footings provided the recommendations contained in this report are followed. We recommend that all footings be founded at least 12 inches below lowest adjacent finished grade with a minimum footing width of 12 inches. An allowable soil bearing pressure of 2500 pounds per 'square foot may be used for foundation design. We further recommend that all continuous .footings be reinforced with at least one No. 4 bar top and bottom. STE 8741089 July 14,---1987 Page 9 ti.. LATERAL RESISTANCE: Resistance to lateral loads may be provided by friction at the base of the footing and by passive pressure against the adjacent soil. For concrete footings on compacted soil, a coefficient of friction of 0.50 may be used. For calculating passive pressure, an equivalent fluid unit -weight of 300 pounds'per cubic foot may be used. Passive pressure should not exceed 1,500 pounds per square foot. When combining frictional and passive resistance, the latter should be reduced by one- third. SETTLEMENT CHARACTERISTICS: It is our opinion that the total and/or differential settlements for the proposed - building will be within tolerable limits. EXPANSIVE CHARACTERISTICS: The prevailing foundation soils were found _to _be nondetrimentallx,. expansive and will not require special consideration and/or design. SOLUBLE SULFATES: Two representative samples of the encountered soils were tested to determine their soluble sulfate content. The results of these tests, as shown on Plate No. 25 indicate a very low sulfate content. In view of these test results, it is our opinion that Type V cement will not be required at this site. 'LIMITATIONS REVIEW, OBSERVATION AND TESTING The recommendations presented in this report are contingent upon our review of final plans and specifications. The soil engineer and engineering geologist should review and verify the compliance of the final grading plan with this C STE 8741089 July 14, 1987 Page 10 report and with Chapter 70 of the Uniform Building Code. It is recommended that Soil and Testing Engineers, Inc. be retained to provide continuous soil engineering services during the earthwork operations. This is to observe compliance with the design concepts, specifications, and recommendations, and to allow for design -changes in the event that subsurface conditions differ from those anticipated prior to start of construction. UNIFORMITY OF CONDITIONS The recommendations and -opinions expressed in this report reflect our best estimate of the project requirements based on an evaluation of the subsurface soil conditions encountered at the subsurface exploration locations and the. assumption that the soil conditions do not deviate ap_preciably_. from . those _encouptered. It should be recognized that the performance of the foundations and/or cut and fill slopes may be influenced by undisclosed or unforeseen variations in the soil conditions that may occur in the intermediate and unexplored areas. Any unusual conditions :not covered in this report that may_ be encountered during site development should be brought to the attention of the soils engineer sothat he may make modifications if necessary. CHANGE IN SCOPE This office should be advised of any changes in -the project' scope of proposed site grading so that it may be determined if the recommendations contained herein are valid. This should be verified in writing or modified by a written addendum. •STE 8741089 TIME LIMITATIONS July 14, 1987 Page 11 The findings of this report are valid as of this date. Changes in the condition of a property can, however, occur with the passage -of -time, whether they be due to natural processes or the work of man on this or adjacent properties. In addition, changes in the State -of -the -Art and/or government codes may occur. Due to such changes, the findings of this report may be invalidated wholly or in part by changes beyond our control. Therefore, this report should not be relied upon after a period of two years without a review by us verifying the validity of the conclusions and recommendations. PROFESSIONAL STANDARD In the performance of our professional services, we comply with the standard of care and skill ordinarily vexercised under similar circumstances by members of our profession currently practicing under similar conditions and in the same. locality. The client —recognizes that subsurface conditions may vary from those encountered at the locations where our borings, surveys, and explorations are made, and that our data, interpretations, and recommendations are based solely on the` information obtained by us. We will be responsible for those data, interpretations, and ° recommendations, but shall not be responsible for the interpretations by others of the information developed. Our services consist of professional consultation and observation only, and no warranty, express or implied, is made or intended in connection with the work performed by us or by the proposal for consulting or other services or by the furnishing of oral or written reports or findings. STE 8741089 July 14, 1987 Page 12 CLIENT'S RESPONSIBILITY It is the responsibility of Presley of Southern California or their representatives to ensure that the information and recommendations contained herein are brought to the attention of the engineer and architect for the project and incorporated into the project's plans and specifications. It is further their responsibility to take the necessary measures to insure that the contractor and his subcontractors carry out such recommendations during construction. FIELD EXPLORATION Twenty subsurface explorations were made at the locations indicated on the --attached Plate No. 1 on June 1, 1987 and June 2, 1987. These explorations consisted oftrenches dug by means of a backhoe. The fieldwork was conducted under the observation of our engineering geology personnel. The explorations were carefully logged—when--made:—These logs are presented on the following Plate Nos. 3 through 22. The soils are described in accordance with the Unified Soils Classification System as illustrated on the attached simplified chart on Plate No. 2. In addition, a verbal textural description, the wet color, the apparent moisture and the density or consistency are provided. The density of granular soils is given as either very loose, loose, medium dense, dense, or very dense. The consistency of silts or clays is givenas either very soft, soft, medium stiff, stiff, very stiff, or hard. Disturbed and undisturbed samples of typical and representative soils were obtained and returned to the laboratory for testing. C STE 8-741089 July 14, 1987 Page 13 LABORATORY TESTING PROGRAM Laboratory tests were performed in accordance with the generally accepted American Society for Testing and Materials (ASTM) test methods or suggested procedures. A - brief description of the tests performed is presented below: A. MOISTURE -DENSITY: Field moisture content and dry density were determined following the field investigation. This information was an aid to classification and permitted recognition of variations in material consistency with depth. The dry weight is determined _in pounds _per -__cubic_ foot, and the field moisture content is determined as a percentage of the soil's dry weight. -The results are summarized in the trench logs. . CLASSIFICATION: Field classifications were verified in the laboratory by visual examination. The final soil class- ifications are in accordance with the Unified Soil Classification System. C. DIRECT SHEAR TEST: Direct shear tests were performed to determine the failure envelope based on yield shear strength of remolded specimens. The shear box was designed to accommodate a sample having a diameter of 2.375 inches and a height of 1.0 inch. Samples were tested at different vertical loads and at saturated moisture content. The shear stress was applied at a constant rate of strain of approximately 0.05 inches per minute. The results of these tests are presented on Plate No. 23. C • STE 8741089 July 14, 1987 Page 14 D. COMPACTION TEST: The maximum dry density and optimum moisture content of typical soils were determined in the laboratory in accordance with-_ASTM--Standard_.Test D-1557- 78, Method A. The results of these tests are presented on the attached Plate No. 23. E. GRAIN -SIZE DISTRIBUTION: The grain size distribution was determined for three representative samples in accordance with ASTM Standard Test D-422. The results of these tests _are presented in curve form on Plate No. 24. SUBSURFACE EXPLORATION LEGEND • (: • UNIFIED SOIL CLASSIFICATION CHART SOIL DESCRIPTION GROUP SYMBOL I. COARSE GRAINED, more than half of material is larger than No. 200 sieve size. GRAVELS CLEAN GRAVELS GU re tan half of coarse fraction is larger than No. 4 GP sieve size but smaller than 38. GRAVELS WITH FINES (Appreciable amount of fines) SANDS CLEAN SANDS 14 re than half of coarse fraction is smaller than No. 4 sieve size. SANDS WITH FINES ' (Appreciable amount of fines) II FINE GRAINED, more than half of material is smaller than No. 200 sieve size. SILTS AND CLAYS Liquid Limit. less than 50 SILTS AND CLAYS Liquid limit greater than 50 HIGHLY ORGANIC SOILS PT GM GC TYPI:AL NAMES Well graded ;ravels, gravel - sand mixtures, little or no fines. Poorly graded gravels, gravel sand mixtures,. little or no fines. Silty gravels, poorly graded gravel -sand -silt mixtures. Clayey gravels, poorly . graded gravel -sand, clay mixtures. SW Well graded sand, gravelly sands, little or no fines. SP Poorly graded sands. gravelly sands, little or no fines. 91 Silty sands, poorly graded sand and silty mixtures. SC- Clayey sands. poorly graded sand and clay mixtures. ML Inorganic silts and very fine sands, rock flour. sandy silt or clayey -silt -sand - mixtures with slight plas- ticity. CL Inorganic clays of low to medium plasticity, gravelly clays, sandy clays, silty clays, lean clays. OL Organic silts and organic silty clays or low plasticity. NI Inorganic silts, micaceous or diatomaceous fine sandy or silty soils, elastic • silts. CH Inorganic clays of high plasticity, fat clays. OH Organic clays of medium to high plasticity. Peat and other highly organic soils. — Water level at time of excavation or as indicated US — Undisturbed, driven ring sample or tube sample CK — Undisturbed chunk sample BG — Bulk sample SP — Standard penetration sample SOIL end TESTING ENGINEERS INC. sr: RRR DATE: 7/13/87 JOS NUMBER: 8741089 Plate No. • 130 - 12/86 • a W 0 SAMPLE TYPE CLASSIFICATION TRENCH NUMBER 1 ELEVATION DESCRIPTION z cc Q F- a 0 a i DRY DENSITY a 1- 2 US --Light-gray brown, SILTY SAND w/gravels Dry -humid Loose 0.8 3' 4- GM Gray, SILTY GRAVEL Dry -humid Loose 5- 6- 7- 9 US SM/GM Gray brown, GRAVELLY. SAND w/some cobbles Grades to light yellow brown Humid Med. dense Bottom at 9'. No groundwater encountered. e7 SOIL and TESTING ENGINEERS INC. .A4 SUBSURFACE EXPLORATION LOG LOGGED BY: MH DATE LOGGED: 6/1/87 JOB NUMBER: 8741089 Plate No. 3 H a. w 0 SAMPLE TYPE CLASSIFICATION TRENCH NUMBER 2 ELEVATION DESCRIPTION 2 CC Q U) a a 2 APPARENT CONSISTENCY OR DENSITY DRY DENSITY a W 27-4 C Z j W O z 2 O U BG 2-- US 3- 4- US 6- 7— SM SM SP GM Light gray brown,STLTY—SAND Dry -humid w/gravels Loose Yellow brown, SANDY GRAVEL/ GRAVELLY SAND w/ some cobbles Humid Loose-med. dense 0.9 8- 9- 10- 11— SM/SP Yellow brown to dark brown,. SILTY POORLY GRADED SAND w/gravels Humid Med. dense 12— Bottom at 11 1/2' No groundwater encountered. • SOIL and TESTING ENGINEERS INC. SUBSURFACE EXPLORATION LOG LOGGED BY: MH DATE LOGGED: 6/1/87 JOB NUMBER 8741089 Plate No. 4 • 0- 0 SAMPLE TYPE TRENCH NUMBER 3 ELEVATION DESCRIPTION Z CC Q I- < - a i OR DENSITY DRY DENSITY 0 a >Z O < w a. CC 0 US SM Gray brown, SILTY SAND Dry -- - Loose - 2- 3- 4- 5- 6- 8 US US GM Light yellow brown, SANDY GRAVEL w/ cobbles Dry -humid Loose-med. dense 0.5 0.4 9- 10 SM/SP Yellow brown to dark browny GRAVELLY SAND Humid -moist Med. dense Bottom at 10' No groundwater encountered. SOIL and TESTING ENGINEERS INC. SUBSURFACE EXPLORATION LOG LOGGED BY: MH DATE LOGGED: 6/1/87 JOB NUMBER: 8741089 Plate No. 5 • H w a SAMPLE TYPE -J N CLASSIFICATION TRENCH NUMBER 4 ELEVATION DESCRIPTION Z CC ¢ j a N i U 2 Iw- Z la a co a az O O 0 DRY DENSITY v a BG SM Gray brown, GRAVEL -SAND - SILT MIXTURE Dry Loose 2- 3— 5- 6 GM US Yellow brown, SANDY GRAVEL Dry -humid Loose-med. dense 0.7 _ 9- 10- 11 SM/SP US Yellow brown, GRAVEL -SAND - SILT MIXTURE Humid - moist Med. dense 1.6 Bottom at 11' No groundwater encountered. SOIL and TESTING ENGINEERS INC. SUBSURFACE EXPLORATION LOG LOGGED BY: MH DATE LOGGED: 6/1/87 JOB NUMBER: 8741089 Plate No. 6 • a w 0 w a LU -J a -< -J N CLASSIFICATION TRENCH NUMBER 5 ELEVATION DESCRIPTION F... U • z • ►w- Z a. Z• 0 cc < 0 0 DRY DENSITY C) a. w CC t% w z 1 2- 3 SM US Gray brown, SILTY SAND Dry -humid Loose GM Yellow brown, SANDY GRAVEL Humid Loose-med. dense 4- 5- 6- 8- 10 US SM/SP Light yellow brown, GRAVELLY SAND w/trace cobbles Grades to orange brown Humid - moist 0.9 Bottom at 10' No groundwater encountered. SOIL and TESTING ENGINEERS INC. SUBSURFACE EXPLORATION LOG LOGGED BY: JOB NUMBER: MH 8741089 DATE LOGGED: 6/1/87 Plate No. 7 • r I a W SAMPLE TYPE CLASSIFICATION TRENCH NUMBER 6 ELEVATION DESCRIPTION _ ZLU 2 F- a co a 2 } f. 0 Z Z W W CC F- co a Z 0 OR DENSITY W Q J w CC COMPACTION (%) 2- 3 BG -tight-yellow brown/gray brown, SILTY SAND Dry -humid Iery loose- Med. dense 4 -=- 5 6 8 9—. 10 — 11 GM US Light yellow brown, SANDY GRAVEL w/trace cobbles Grades to dark brown Humid - moist Med. dense 0.5 Bottom at 11' No groundwater encountered. SOIL and TESTING ENGINEERS INC. SUBSURFACE EXPLORATION LOG LOGGED BY: MH JOB NUMBER: 8741089 DATE LOGGED: 6/1/87 Plate No. 8 C 1 SAMPLE TYPE J N CLASSIFICATION TRENCH NUMBER 7 ELEVATION DESCRIPTION APPARENT CONSISTENCY OR DENSITY RELATIVE COMPACTION (% SM US Gray brown, -SitTY--SAND w/trace gravels -Dry -Very loose 2- 3- 6- 8- 9 GW US US Yellow brown, SANDY GRAVEL w/cobbles Dry -humid Loose-med. dense 0.5 1.8 Bottom at 9' No groundwater encountered. SOIL and TESTING ENGINEERS INC. SUBSURFACE EXPLORATION LOG LOGGED BY: MH DATE LOGGED: 6/1/87 JOB NUMBER: 8741089 Plate No. 9 SAMPLE TYPE CLASSIFICATION TRENCH NUMBER 8 ELEVATION DESCRIPTION LIJ Z CC Q I- cn a. — a. 2 APPARENT CONSISTENCY OR DENSITY DRY DENSITY U a w - J w CC 0 U 0 U SM Gray brown, SILTY SAND Dry Loose—med., dense 2— 3-- 4-- 5' 9 GW US Yellow brown to gray, SANDY GRAVEL Dry -humid Loose-med. dense 0.5 SM/SP Orange brown, GRAVELLY SAND Humid - moist Loose-med. dense Bottom at 9' No grQundw,ater --encountered. SOIL end TESTING ENGINEERS INC. SUBSURFACE EXPLORATION LOG LOGGED BY: MH DATE LOGGED: 6/1/87 JOB NUMBER: 8741089 Plate No. 10 r- • a. w 0 SAMPLE TYPE —J ITS CLASSIFICATION TRENCH NUMBER 9 ELEVATION DESCRIPTION w w cc Q 0 2 OR DENSITY DRY DENSITY 0 > O U Q wcc Q, O U US SM Gray brown, SILTY SAND w/gravel + cobbles Dry Loose 0.4 3— 4- 5- 6— (. (;. 8- 9— US US GW Light gray to yellow brown, SANDY GRAVEL Grades to orange brown Dry -humid Loose-med. dense 0.6 0.4 10— Bottom at 9 1/2' No groundwater encountered. SOIL and TESTING ENGINEERS INC. SUBSURFACE EXPLORATION LOG LOGGED BY: MH DATE LOGGED: 6/1/87 JOB NUMBER: 8741089 Plate No. 11 • 2 a. w 0 1 W a. W J co -J CLASSIFICATION TRENCH NUMBER 10 ELEVATION DESCRIPTION } � U Z uj Q W a o z Q 0 0 DRY DENSITY o. -J CC COMPACTION (%) US SM Gray brown, SILTY SAND w/gravel Dry Loose 2- BG 4- 5- 9- US 10- GW Light gray to light yellow brown, SANDY GRAVEL w/cobbles Dry -humid Med. dense 1.3 12— Bottom at 11 1/2' No groundwater encountered.. SOIL end TESTING ENGINEERS INC. Adii SUBSURFACE EXPLORATION LOG LOGGED BY: MH DATE LOGGED: 6/1/87 JOB NUMBER: 8741089 Plate No. 12 C • w w 0 SAMPLE TYPE J co CLASSIFICATION TRENCH NUMBER 11 ELEVATION DESCRIPTION W CC Q CC N a. 0 a i OR DENSITY U W V G a et ' . RELATIVE COMPACTION (%) 1- 2- 3- 4 US US SM —L4gh-t-gray-to- light yellow brown, SILTY SAND w/gravel Dry -humid Loose 0.9 6- 9- 10 GM Yellow brown, SANDY GRAVEL Grades to "orange brown Dry -humid Loose-med. dense Bottom at 10' No groundwater encountered. SOIL and TESTING ENGINEERS INC. SUBSURFACE EXPLORATION LOG LOGGED BY: MH DATE LOGGED: 6/1/87 JOB NUMBER: 8741089 Plate No. 13 w 0 1 SAMPLE TYPE -J N CLASSIFICATION TRENCH NUMBER 12 ELEVATION DESCRIPTION ¢ I - a 0 a i } 0 Z Z cr I- N a Z 0 Z. w 0 cc 0 Co W v 0 a ¢_ 0 w CC D Z cn w 2 O U w 5 cc COMPACTION (%) SM Gray brown, SILTL.SMlD- w/gravels wry-humid-- --L-oose 2- 3- 4- 5- 6- 9- to- BG US GM Light gray to yellow brown, SANDY. GRAVEL w/cobbles Grades to orange brown Dry -humid Loose-med. dense 1.1 Bottom at 10': No groundwater encountered. SOIL and TESTING ENGINEERS INC. SUBSURFACE EXPLORATION LOG LOGGED BY: MH DATE LOGGED: .6/1/87 JOB NUMBER: 8741089 Plate No. 14 • H a. w a SAMPLE TYPE TRENCH NUMBER 13 ELEVATION DESCRIPTION Z CC CC I - a. — a i U I- Z Z W W Q 6- CL am a Z U OR DENSITY DRY DENSITY V a w Z > < H J < W a. cc i 0 U 1— US SM Tan to light gray, SILTY SAND w/gravels Dry Loo-se-- 2- 3- 4- 5- 6- 8- 9- 10 US SM/SP Yellow brown, slightly SILTY POORLY GRADED SAND Grades to orange brown Dry -humid Loose-med. dense 1.4 41.1 Bottom at 10' No.groundwater encountered. SOIL end TESTING ENGINEERS INC. .44 SUBSURFACE EXPLORATION LOG LOGGED BY: MH DATE LOGGED: 6/2/87 JOB NUMBER: 8741089 Plate No. 15 • w a W 0 SAMPLE TYPE _J O CLASSIFICATION TRENCH NUMBER 14 ELEVATION DESCRIPTION- - z CC Q H <CL a i V Z Z W � CCN a CO Q Z 0 OR DENSITY DRY DENSITY a W g CC F. F, Z z to W 2- 3- 4- 5 SM GW BG Gray brown, SILTY SAND Light gray to yellow brown,_ SANDY GRAVEL w/cobbles Dry Dry -humid Loose Loose-med. dense 6- - US GM SM .SP Yellow brown to orange brown, SILTY -SANDY GRAVEL Humid Med. dense 1.0 Bottom at 7' due to heavy caving. No groundwater encountered. SOIL and TESTING ENGINEERS INC. SUBSURFACE EXPLORATION LOG LOGGED BY: MH DATE LOGGED: 6/2/87 JOB NUMBER: 8741089 Plate No. 16 2 2 SAMPLE TYPE Jo CLASSIFICATION TRENCH NUMBER 15 ELEVATION DESCRIPTION Z CC CC D. y a. i } Z Z ia CO cc et N W ZQ. CD O cc 0 O DRY DENSITY SM US Gray brown, SILTY SAND w/gravel + cobbles Dry -humid Loose 0.4 3— 6— US BG US GW SM Gray to yellow brown, SANDY GRAVEL w/cobbles Orange brown,_FINE SILTY SAND Dry -humid Moist Loose-med. dense Med. dense 0.6 6.4 12 SP Yellow brown, GRAVELLY SAND Moist Med. dense Bottom at 12' No groundwater encountered. iflr SOIL and TESTING ENGINEERS INC. SUBSURFACE EXPLORATION LOG LOGGED BY: MH DATE LOGGED 6/2/87 JOB NUMBER 8741089 Plate No. 17 • w a. w c SAMPLE TYPE J co CLASSIFICATION TRENCH NUMBER 16 ELEVATION DESCRIPTION Z ¢ UJ CC I- < U) a a. O 2 DRY DENSITY a w Q J w Q COMPACTION (%) 1— US SM 3.ray brown, SILTY SAND w/gravel Dry Loose - 3- 4- 5- 6- 7— • — US 9-- GM Yellow brown to brown, --SANDY GRAVEL w/cobbles Dry -humid Loose-med. dense 2.6 10— Bottom at 9 1/2' No groundwater encountered. SOIL and TESTING ENGINEERS INC. SUBSURFACE EXPLORATION LOG LOGGED BY: MH DATE LOGGED: 6/2/87 JOB NUMBER: 8741089 Plate No. 18 • (. 2 a. w 0 1 SAMPLE TYPE J Co CLASSIFICATION TRENCH NUMBER 17 ELEVATION DESCRIPTION ;APPARENT DRY DENSITY a. COMPACTION (%) SM BG Gray to yel tow; -SILTY -SAND-- - --Dry - Loose 2- 3-- 4— US 5- 6- 7- 8— GM Yellow brown, SANDY GRAVEL w/cobbles -Grades to orange brown - Dry -humid 4.0 Loose-med. dense 1.5 Bottom at 9' No groundwater encountered. SOIL and TESTING ENGINEERS INC. SUBSURFACE EXPLORATION LOG LOGGED BY: MH DATE LOGGED: 6/2/87 JOB,NUMBER: 8741089 Plate No. 19 C_ C • w w 0 SAMPLE TYPE -J N CLASSIFICATION TRENCH NUMBER 18 ELEVATION DESCRIPTION LIJ Z CC ICJ CC t- aCO — APPARENT V w o Z cc U O wCC 3 Z F- 8 > 0 gU w a. CC 2 0 0 2— US SM Gray to tan, SILTY SAND w/gravel Dry -Loose 0.6 3- 4— US 7- 8- 9 10— GM Yellow brown, SANDY GRAVEL Grades to orange brown Grades to brown . Dry -humid Med. dense 1.7 11 — Bottom at 10 1/2' No groundwater encountered. SOIL and TESTING ENGINEERS INC. SUBSURFACE EXPLORATION LOG LOGGED BY: MH DATE LOGGED: JOB NUMBER 8741089 6/2/87 Plate No. 20 • r w 0 SAMPLE TYPE Z 0 J co co— J U TRENCH NUMBER 19 ELEVATION DESCRIPTION I- ILI w CC CC < N O. APPARENT DRY DENSITY U a w w _cc COMPACTION (%) 1 2 SM Gray brown, SILTY SAND m/gravel Dry Loose 3- 4— US BG SM/SP Yellow brown, GRAVELLY SAND w/cobbles Dry -humid Loose-med. dense 0.8 5- 6- 7-- 8— GM Orange brown, SANDY GRAVEL wjcobbl es Humid Med. dense 9— Bottom at 8 1/2' No groundwater encountered. SOIL and TESTING ENGINEERS INC. SUBSURFACE EXPLORATION LOG LOGGED BY: DATE LOGGED: MH 6/2/87 JOB NUMBER: 8741089 Plate No. 21 • ( w a SAMPLE TYPE CLASSIFICATION TRENCH NUMBER 20 ELEVATION DESCRIPTION APPARENT CONSISTENCY OR DENSITY DRY DENSITY U a w D w O w a J w Q COMPACTION (%) 1- 2- 3- 4- SM US US Gray to tan, SILTY SAND w/cobbles Dry -humid Loose 1.6 5- 6- 10 SM/SP Yellow brown, SLIGHTLY SILTY POORLY GRADED SAND w/gravels Grades to orange brown Dry Med. dense, Bottom at 10' No groundwater encountered. 411.0.1 SOIL and TESTING ENGINEERS INC. SUBSURFACE EXPLORATION LOG LOGGED BY: MH DATE LOGGED: 6/2/87 JOB NUMBER: 8741089 Plate No. 22 DIRECT SHEAR TEST RESULTS SAMPLE — --- DESCRIPTION - angle of Internal friction C) cohesion Intercept (psf) T-2 @ 0-2' Remolded 59 90% 40 0 T-4 @ 0-1' Remolded to 90% 37 75 T-10 @ 3-4' Remolded to 90% 36 50 T-19 @ 2-3" Remolded to 90% 37 0 . MAXIMUM DENSITY and OPTIMUM MOISTURE CONTENT ASTM D-1557 METHOD A SAMPLE DESCRIPTION - maximum density (pcf) optimum moisture content (%) T-2 @ 0-2' Brown, SANDY GRAVEL/GRAVELLY. SAND 131.5 7.0 T-4 @ 0-1' Dark Brown, GRAVELLY SILTY SAND 129.3 9.2 • T-10 @ 3-4' Tan brown. GRAVELLY SAND W/COBBLES 132.7 6.5 T-19 @ 2-3' Tan brown, GRAVELLY SAND W/COBBLES 128.7 6.2 II/ 801E end TESTING ENGINEERS INC. BY RN DATE 7/10/87 AC JOB NO. 8741089 Plate No. 23 r`• • 8801P1.8 'ON eor z Pt 'oN •WId 0 m L8/OL/L N N m NOIll81a1Si0 10 9 8 1 36• 18• • US{ Standard Sieves 2" I• %• *10 *20 *40 *60 Hydrometer (Minutes) 1 . 6. 3 1 • '3b' 44 ' M6 *5o .I�O Ng09 I 2 a 30 -IOU i+�B 1.24• cr;* i 1: 2 5 3D ISO - I4• • 4 1 • . . 3 • .967. •6 .4 • ,5 , •9878 �' )98785. 4 3 2 98766 4 3• 2 )00 100 10 5 4 3 2 9.8785 3 2 9876 4 3y2 OI 5 4T3 2 .001 PARTICLE Groin Size (m ml T-2 at O-2' ' — — — — — — T-4 at 1' SIZE T-19 at 2-3' LIMITS 1 BOULDER i COBBLES 1 GRAVEL SAND SILT OR CLAY Coarse Fine Coarse Medium Fine (12 In.) 3 in. 3/4 In. No.4 Nor10 No.40 No.200 U.S. STANDARD SIEVE SIZE (50 Off.) L. a ASSOCIATED LABORATORY'S 806 North. Batavia - Orange, California 92668 - 714/771-6900 CLIENT Soil & Testing Engineers LAB NO. F34565 -165-West Orangethorpe -Placentia, CA 92670 REPORTED 6/17/87 Attn: Bob Russell SAMPLE IDENTIFICATION BASED ON SAMPLE Soil As Below As Submitted 8731072 - B1 @ 0-2' 8741078 - T2 @ 11' -8741085 - B2 @ 1-3' (-8741089 - T4 @ 0-1' 8741089 - T10 @ 3-4' RECEIVED 6/11/87 SULFATE 0.153% ND<0.001% 0.026% ND<0.001% ND<0.001% 8751044 - T2 @ 2' ND< 0.001% 8751046 0.012% ASSOCIATED LABORS ORIE Tit L. P TLP/ql NOTE: Unless notified in writing, all samples will be discarded by appropriate disposal protocol 30 days from date reported. The reports of the Associated Laboratories are confidential property of our clients and may not be reproduced or used for publication In part or in full without our written permission. This Is for the mutual protection of the public, our clients. and ourselves. TESTING & CONSULTING Chemical • Microbiological • Environmental • ;•1 10M TENTATIVE TRACT 12314 -- BASELINE ROAD -NEAR -CITRUS AVENUE FONTANA, CALIFORNIA RECOMMENDED GRADING SPECIFICATIONS - GENERAL PROVISIONS GENERAL INTENT The intent of these specifications is to establish procedures for clearing, compacting natural ground, preparing areas to be filled, and placing and compacting fill soils to the lines and grade-s- shown on the accepted plans. The recommendations contained in the preliminary geotechnical investigation report and/or the attached Special Provisions are a part of the Recommended Grading Specifications and shall supersede the provisions contained hereinafter in the case of conflict.-- These specifications shall only-b-e--us-e-d in conjunction with the geotechnical report for which they are a part. No deviation from these specifications will be allowed, except where specified in the geotechnical report or in other written communication signed by the Soil Engineer. OBSERVATION AND TESTING Soil and Testing Engineers, Inc., shall be retained as the Soil Engineer to observe and test the earthwork in accordance with. these specifications. It will be necessary that the Soil Engineer of his representative provide adequate observations so that he may provide an opinion that the work was or was not accomplished as specified. It shall be the responsibility of the contractor to assist the soil engineer and to keep him Appendix, Page 2 apprised of work schedules, changes, and new information and data so that he may provide these opinions. In the event that any unusual conditions not covered by the special provisions or preliminary soil report are encountered during the grading operations, the Soil Engineer shall be contacted for further recommendations. If in the opinion of the Soil Engineer, substandard conditions are encountered, such as: questionable or unsuitable soil, unacceptable moisture content, inadequate compaction, adverse weather, etc., construction would be stopped until the conditions are remedied or corrected or he shall recommend rejection of this work. Test methods used to determine the degree of compaction should be performed in accordance with the following American Society for Testing -and Materials test methods: Maximum Density & Optimum Moisture Content - ASTM D-1557-78. Density of Soil In -Place - ASTM D-1556-64 or ASTM D- 2922. All densities shall be expressed in terms of Relative Compaction as determined by the foregoing ASTM testing procedures. PREPARATION OF AREAS TO RECEIVE FILL All vegetation, brush and debris derived from clearing. operations shall be removed, and legally disposed of. All areas disturbed by site grading should be left in a neat and finished appearance, free from unsightly debris. After clearing or benching, the natural ground in areas to be filled shall be scarified to a depth of 6 inches for the minimum degree of compaction in the Special Provisions or the recommendation contained in the preliminary geotechnical report. Appendix, Page 3 All loose soils in excess of 6 inches thick should be removed to firm natural ground which is defined as natural soils which - possesses an in -situ density of at least 90% of its maximum dry density. When the slope of the natural ground receiving fill exceeds 20% (5 horizontal units to 1 vertical unit) , the original ground shall be stepped or benched. Benches shall be cut to a firm competent soil condition. The lower bench shall be at least 10 feet wide -or 1 1/2 -times the equipment width whichever is greater, and shall be sloped back into the hillsideat a gradient of not less that two (2) percent. All other benches should be at least 6 feet wide. The horizontal portion of each bench. shall be compacted prior to receiving fill as specified hereinbefore for compacted .natural_ground_ Ground slopes flatter than 2D% shall be .benched whenconsidered necessary by the Soil Engineer. - . Any abandoned structures encountered during grading operations must be totally removed. All underground utilities to be abandoned beneath any proposed_ structure should be removed from within 10 feet of the structure and properly capped off. The resulting depressions from the above described procedures should be backfilled with acceptable soil that is compacted to the requirements of the Soil Engineer. This includes,but is not limited to, septic tanks, fuel tanks, sewer lines or leach lines, storm drains, and water lines. Any buried structures or utilities not to be abandoned should be brought to the attention of the Soil Engineer, so that he may determine if any special recommendation will be necessary. All water wells which will be abandoned should be backfilled and capped in accordance to the requirements set forth by the Soil Engineer. The top of the cap should be at least 4 feet below finish grade or 3 feet below the bottom of footing whichever is Appendix, Page 4 greater. The type of cap will depend on the diameter of the well and should be determined by the Soil Engineer and/or a qualified Structural Engineer. FILL MATERIAL Materials to be placed in the fillshallbe approved by the Soil Engineer and shall be free of vegetable matter and other deleterious substances. Granular soil shall contain sufficient fine material to fill the voids. The definition and disposition of oversized rocks, expansive and/or detrimental soils are covered in the geotechnical report or special provisions. Expansive soils, soils of poor gradation, or soils with low strength characteristics may be thoroughly mixed with other soils to provide satisfactory fill material, but only__with_the explicit consent of the Soil Engineer-.- Any import material shall be approved by the Soil Engineer before being brought to _______the site. PLACING AND COMPACTION OF FILL Argo Approved fill material shall be placed in areas prepared to receive fill in layers not to exceed 6 inches in compacted thickness. Each layer shall have a uniform moisture content in the range that will allow the compaction effort to be efficiently applied to achieve the specified degree of compaction. Each layer shall be uniformly compacted to a minimum specified degree of compaction with equipment of adequate size to economically compact the layer. Compaction equipment should either be specifically designed for soil compaction or of proven reliability. The minimum degree of compaction to be achieved is specified in either the Special Provisions or the recommendations contained in the preliminary geotechnical report. Appendix, Page 5 When the structural fill material includes rocks, no rocks will --be allowed to nest and all voids must be carefully filled with soil such that the minimum degree of compaction recommended in the Special Provisions is achieved. The maximum size and spacing of rock permitted in structural fills and in non- structural fills is discussed in the geotechnical report, when applicable. Field observation and compaction tests to estimate the degree of compaction of the fill will be taken by the Soil engineer or his representative. The location and frequency of the tests shall be at the Soil Engineer's discretion. When the compaction test indicates that a particular layer is less than the required degree of compaction, the layer shall be reworked to the satisfaction of the Soil Engineer and until the desired relative compaction has been obtained. Fill slopes shall be compacted by means_ of_sheepsfoot_rollers or other suitable equipment. Compaction by " sheepsfoot" rollers shall be at vertical intervals of not greater than four feet. In addition, fill slopes at ratios of two horizontal to one vertical or flatter, should be gridrolled. Steeper fill slopes shall be over -built and cut -back to finish contours after the slope has been constructed. Slope compaction operations shall result in all fill material six or more inches inward from the finished face of the slope having a relative compaction of at least 90% of maximum dry density or that specified in the Special Provisions section of this specification. The compaction operation of the slopes shall be continued until the Soil Engineer is of the opinion that the slopes will be stable in regards to surficial stability. Slope tests will be made by the Soils Engineer during construction of the slopes to determine if the required compaction is being achieved. Where failing tests occur or C roblems arisee Contractor wrill n'#a�,� �, conditios by Jwri.tten °commune catilon n .ii'y ;7 .-. v�'-`.k'<h" P44:,,, p'z''.r��F, !•D�i'�rxd , ad5^,• }' � ..,, h +r f�S r'� En'� ?a gineer's or phis representative min the form ♦.. r e'"„�. t `` ti�� a •q�a. �y,t�C � [ t ��,}�! �.xr�� x �'rr p `r�r 5.7a� � S � � y;� •rff �r�ro �''� �%y s, "Y' y y� r•.vi4ii' re or `� }�'t'?'`,fi 4P M,J,r< .,*y ..ra ,� '-" �. a� J+d..``� Y y T'7 •s ,�.cx T �1`{�* `Ss. }' ,d^4.-Af37 �vsi'�'�� a�.°a. � ... � t''...� �..'fr•�w`. �.�,'r�:�� ,' �; � . ". p L-Y;b�,.::.���� r'��,Y rt� .`S-., � �� s If the method tof achieving the required slope compaction :• ..,.b +.v _ .ter �i•.f., �C - + ".gas,,.- f . a�,." rAx selected aby ..the Contractor fails to produce the necessary results, the Contractor shall rework or rebuild .such slopes until the required degree of compaction is obtained, at no cost to the Owner or Soils Engineer. t '" he Engineering Geologist shall inspect cut slopes excavated in ock or :lithified : formational material during the gradin • • F+ i.. :.{ -: operations fat intervals; determined. at :his discretion. If an ieµ:4Y. + ' "t..bs-1tv1r'-•i,V�� y i`,Y )..`r•. 6•e N,.:, x'� k�7 i s - �:d ?� r all be analyzed by the Engineering Geologist an 4ti. determine ifrmitigating'measures,.are£necessary a:t zS.r67 '& .,.;t •i, 5`,3xcTs.,�zorzc `. % _ mtR,',� 1. nd7' c7S? ?i'Gf sd�d4,k`7,?�i'A.P„f..1 4�"f9kr?c'�' :a#�i fi"1 Unless ,otherwise'specifiedz<iin the `geote�gc�,hnical#report li.,: x �?+. 5 f yynp T y 03 t ,,t10-. tiNi'% `� i } 75 j� YLh a 1 aa; ?vets thanthat'a slopes shall be 'excavated ,higher orAsteeper=s - ti?tiLt Fak. 0, tt 'tx4`' `, t�`i ` �X�`r: a7•.' �Et te4=i:�"'$04x,Vag' F?: € 4 :44fa •' �*WOO* the ordinances of the;;controlling Kgovernmental agency: Field ?observation eby the Soil „Engineer orrhs representative R :A i'y,4 '� i".j J +., ..—,4'dr, rr'5.:-: � 'g 'b;. vx•+ yqy<, 't, :r�t +� �,'t 3 �P+L' � {a J,�-���''4�'sA.S ,g�^� 'A� � ,*.r•. *' _ wau -n .1 shall Abe Ma de :the ,filling andr compacting operations Aso .'�F.f41ei W, . VY S `#„.,y L " 1 3�•2 �P"... zt v'fti3•' d r �fit.4, th S�i 7ti 'fir ur.y:<" ^' r. r'+ 'y , '!°'.$';l ir` ` 3rx,. _. ;that he can express his :opinion regarding the conformance of ,the ^t'.`- t, . _ e f !c. �;s -, .:A y - ^.,?; ',* : 'S�v T •._ .v . ,th :; t, t ,,_,- grading with 'acceptable standards Of practice: *okThe:presence of the'Soil Engineer di his representativefor,the observation and testing shall not release the Grading 'Contractor from his duty • , ' • . - • ' " • -4 444,•V- . =;'`' •••• • ,4 • • -`15:7-=':i.:f?,118:4-,,,V!!‘ • „ Fill -,'"unfavorable Weather conditions.:- • when 'work is -interrupted by heavy rain; : filling. operations shall not be resumed until the proper moisture content and density of the fill materials can be achieved. Damaged site conditions resulting from weather or acts of God shall be 'repaired before acceptance of work. . - „ , • e-r... : " RECOMMENDED GRADING SPECIFICATIONS - SPECIAL PROVISIONS The minimum .,.,degree_L'A:pf ..-compaCtionr;to.- be .j:obtained in compactin '''''1.`:•,O ' : natural 4:ground bin.'";.the'icompacted - ecompacted- • •- • 4•77-...•,;'•':?.-•1 : backfill_Lshall:.be at ..least 9O percent. -et "rr*. 4reir, '?§Y•s, TRANSITION LOTS: Where transitions between Cut and filloccur- •,/," ‘t.; ,rg...2 • r \ • ; withinthe 'proposed , g:p,a :'.L'tohtquyFo undercut a minimum of one foot below' the ',:base of the proposed • `•74.1. t44 footings and recompacted as structural backfill.' In certain cases that would be addressed in the geotechnical report, 4,01 PRESLEY of SOUTHERN CALIFORNIA LETTER OF TRANSMITTAL TO: MADOLE AND ASSOCIATES, INC. 1820 E. Sixteenth St. Santa Ana, CA 92701 ATTN• Milt Madole DATE• July 24, 1987 TRACT. 12 314 LOTS. SUBJECT. FONTANA We are enclosing: EXHEREWITH 0 UNDER SEPARATE COVER NO. OF COPIES 1 Soils Report by Soil and testing Engineers, Inc. DESCRIPTION STATUS: SENT FOR YOUR: PLEASE NOTE: ❑ PRELIMINARY 0 APPROVAL 0 REVISIONS ❑ REVISED 0 SIGNATURE 0 ADDITIONS ❑ APPROVED N USE 0 DELETIONS O REVIEWED 0 FILE 0 CORRECTIONS O W INFORMATION 0 REMARKS CC: PRESLEY OF SOUTHERN CALIFORNIA BY• ))avP (;raf 17991 Mitchell South • Irvine, California 92714-6095 • (714) 660-0660 Mailing Address: Post Office Box 19672 • Irvine. California 92713-9672 ) Th cc, /A-,, GEOTECHrICAL SERVICES PROPOSAL EVALUATION CRITERIA .%h / 1) Cypress Sewer i s-L 2) Citrus Storm Drain ,y�dr -j 3) Highland/Haven Sewer & Storm Drain 4) Baseline and Almeria Sewer WEIGHTED WEIGHTED FACTOR SCORE* WEIGHT SCORE 1. Qualifications of Firm a. Relevant experience of the firm b. Reputation of firm, based upon references c. Qualifications of personnel to be assigned; experience, training, communicative skills 2. Technical Approach a. Responsiveness to meet or exceed request for proposal b. Schedule validity or applicability c. Ability to communicate "product" in an organized, clear and convincing manner Fees (Blind env recommended pro *Score nacceptable 1 - Poor 2 - Fair 3 - Good 4 - Excellent Reviewer's Name: lope of osal) FIRM'S NAME: 3 Z, 3 2.� 20% 10% 10% ,r Subtotal 90% -zs-0 10% TOTAL 100% C f/J — Date: 7- z zcJ� • H • �J • INCORPORATED P.O. Box 231 • 1355 East Cooley Drive, Colton, CA 92324 • Phone (714) 824-7210 11910 Hesperia Road, Suite 2 • Hesperia, CA 92345 • (619) 949-0006 May 27, 1992 City of Fontana Community Development Department/Engineering Division 8353 Sierra Avenue Fontana, California 92335 Attention: Mr. Robert W. Weddle Subject: Proposal to Provide Engineering Geotechnical Services City of Fontana, California Dear Mr. Weddle: As requested, we are submitting this proposal to provide geotechnical observation and compaction testing services for four capital improvement projects, as well as a geotechnical evaluation of one of the projects. The specific location of each project and the scope of services required were indicated in your Request for Proposal letter dated May 7, 1992. As we understand it, our services would be required for the Cypress Avenue Sewer Line Construction, Citrus Avenue Storm Drain, Infra —Structure Improvements to Tract No. 3348 (Highland/Haven Tract) and Sewer Construction on Baseline and Almeria Avenues in the City of Fontana. In addition, a geotechnical evaluation will be required on the Citrus Avenue Storm Drain project. In preparation of this proposal, the improvement plans for each project available at the City of Fontana were reviewed for specific information regarding quantities, and this information was utilized in preparing the cost estimate for this project. SOILS ENGINEERS • MATERIALS TESTING AND EVALUATION • CONSTRUCTION INSPECTION • J •)• City of Fontana Page No. 2 May 27, 1992 In accordance with your Request for Proposal, our scope of services and the associated costs have been included separately from this letter. To illustrate our knowledge and experience in the area, we have enclosed a partial list of similar projects completed for various clients within the area. Regarding the time frame for completion of the project, the four construction observation projects will proceed according to time frames followed by the general contractor performing the work. Our services are provided as needed by the general contractor and, as such, our time frame is determined by the progress of the project. All compaction testing and observations services will be provided by this firm on a time and materials basis. Regarding the subsurface soils investigation, approximately two to three weeks will be required to issue the final report after completion of the field investigation. A more detailed description of our scope of services, along with estimated costs, has been included in a separate envelope submitted with this proposal. OUALIFICATIONS C.H.J., Incorporated has been providing geotechnical services in the Southern California area since 1964. Our firm has been providing geotechnical investigation services, materials testing and observation, laboratory testing, plant inspections and construction performance testing on aggregate, concrete and asphalt throughout its history. Since inception, we have prided ourselves on the ability to accomplish assigned tasks within time constraints and budget limitations, while maintaining high quality services. Personal interaction and cooperation of all members of this firm makes such compliance our routine. With our main office on Cooley Drive in Colton and our readily available staff, we will be able to respond to your needs instantaneously. In this way, you can be assured that our services will be completed in a timely fashion. City of Fontana Page No. 3 May 27, 1992 C.H.J. maintains laboratory services to provide full support for design and construction performance testing on soils, asphalt concrete, structural concrete and roadway bases and has been inspected by the National Bureau of Standards, Cement and Concrete Reference Laboratory, the Army Corps of Engineer and State of California Department of Transportation. These services have been provided to both public and private sector clients on a broad range of projects. As required, a brief project organizational chart has also been included as an enclosure to this letter to illustrate the organizational structure of our company. As indicated within the chart, all field personnel are supervised by our Operations Manager and all laboratory personnel are supervised by our Laboratory Director. The field and laboratory sections of the project are in turn managed and supervised by the Staff Engineer assigned to the specific project. Once the field and laboratory test data are gathered, the Staff Engineer combines all data and formulates the engineering recommenda— tions to be provided. The Staff Engineer is in turn supervised the Project Engineer who is involved in all projects and also maintains direct contact with the field and laboratory sections as required. Before all conclusions and engineering recommendations are finalized, the project is discussed in detail with the Principal Engineer who maintains overall responsibility. Throughout the project the Staff Engineer will serve as the client contact in order to keep the client abreast with developments. Prior to the beginning of the project, we would request that our firm be present at the pre — construction meeting in order to introduce ourselves to all parties involved, as well as establish our scope of responsibility for the project. The specific technicians assigned to each project, as well as the office contacts will be notified to the City of Fontana prior to start of the project. As required, resumes of key personnel indicating their experience with the company have been enclosed with this letter. Also included with this proposal letter is our current SF254 form to illustrate our experience. (C•N•c�• City of Fontana Page No. 4 May 27, 1992 We appreciate the opportunity to submit this proposal, and look forward to continuing our excellent working relationship with the City of Fontana. We would be happy to personally discuss the scope of services outlined in this letter if desired. If you should have any questions concerning this proposal, please do not hesitate to contact this firm at your convenience. Respectfully submitted, C.H.J., INCORPORATED Ben Williams, Staff Engineer Donald M. Matthews, P.E. Project Engineer Robert J. Johnson, P.E. Senior Vice President BW/DMM/RJJ:tlp Enclosures: Partial List of Similar Projects Resumes Project Organizational Chart SF254 Form PARTIAL LIST OF SIMILAR PROJECTS Project Name and Location Name and Address of Client Chino Hills InfraStructure City of Chino Hills, CA Fontana Heritage Project City of Fontana, CA Various Storm Drain and Flood Control Projects Riverside County, CA Various Utility Line Projects City of San Bernardino, CA Broderson Reservoir Pipeline Pigeon Pass Road Moreno Valley, CA City of Chino Hills Chino Hills Manager's Office 13260 Central Avenue Chino Hills, CA Contact: Mr. Chris Vogt Tel: (714) 590-5280 City of Fontana c/o Fontana Heritage West End Assoc. 230 Newport Center Dr., Ste. 300 Newport Beach, CA Contact: Mr. Roger Hatch Tel: (714) 720-1166 Riverside County Flood Control and Water Conservation District 1995 Market Street Riverside, CA Contact: Mr. Steve Thomas Tel: (714) 275-1200 City of San Bernardino 300 North "D" Street San Bernardino, CA Contact: Mr. Roger Hardgrave Tel: (714) 384-5111 Eastern Municipal Water District P. O. Box 8300 San Jacinto, CA Contact: Mr. Joe Van Sickle Tel: (714) 925-7676 Cypress Avenue Sewer NBS/Lowry Cypress Avenue 164 Hospitality Lane City of Fontana, CA San Bernardino, CA Contact: Mr. Chuck Diephulz Tel: (714) 884-1401 PARTIAL LIST OF SIMILAR PROJECTS Cont'd Project Name and Location Name and Address of Client Spectrum/Smith Site Storm Drain Riverside, CA Railroad Street Improvements Railroad Street Corona, CA Trunk Line Extension Palm Street to Route 10 Rialto, CA Albert A. Webb Associates 3788 McCray Street Riverside, CA Contact: Mr. Richard Teller Tel: (714) 686-1070 City of Corona Department of Public Works 10072 West 6th Street Corona, CA Contact: Mr. Chuck Booher Tel: (714) 736-2291 City of Rialto City Hall, Engineering Department 150 South Palm Avenue Rialto, CA Contact: Mr. Bruce Cluff Tel: (714) 820-2530 NOTE: Additional project information will be provided if needed. ROBERT J. JOHNSON SENIOR VICE PRESIDENT EDUCATION: 1968 San Diego State University, San Diego, California Bachelor of Science ADDITIONAL EDUCATION : MISC. MFMRER: PROFESSIONAL EXPERIENCE : 12-71 to Present California State Polytechnic University California State University, Long Beach San Bernardino Valley College Registered Civil Engineer: RCE 27060 Registered Geotechnical Engineer: GE 443 California Society of Professional Engineers National Society of Professional Engineers American Society of Civil Engineers Society of American Military Engineers C.H.J., INCORPORATED Senior Vice President — Director of Soils & Environmental Divisions Charge responsibility for operation of the soils division including Foundation and Preliminary Soils Investigations, Percolation Studies, Rigid and Flexible Pavement Design and Evaluation, Slope Stability Studies, Engineering Calculations and Grading Control Analysis. Design and Project Engineer for soil cement lake lining operations and evaluation. Evaluations of seismic data and liquefaction potential. Analysis of soil failures and structural distress associated with such failures. Design of chemical soil modification processes. Coordination of field grading control including coordination of Design Civils, Geologists, and Project Engineers. PROFESSIONAL EXPERIENCE : Cont'd 12-71 to Present Preparation and evaluation of specifications for various types of Civil Engineering works including earthwork, lining control and asphalt concrete paving projects. Coordination and evaluation of laboratory data used in the design and evaluation of soils engineering and related projects. Overall responsibility for operation of the Environmental Division. This division consists of geologists, engineers and analysts performing Phase I and Phase II Environmental Site Assessments. Principal in charge, providing technical directives and quality assurance. 3-69 to 12-71 KASLER CORPORATION AND GORDON H. BALL, INC. Materials Engineer Responsible for evaluation and procurement of earthwork materials for a large general engineering contractor. Responsible for evaluation of quantity and quality of various engineering materials. Quantity takeoff evaluation and pricing. Evaluation of construction operations 7-68 to 3-69 C.H.J., INCORPORATED Chief Laboratory Technician and Field Technician Responsible for performance and coordination of laboratory tests. Responsible for calculation and reporting of various tests to engineers. Responsible for field testing and report preparation with respect to field control of engineer— ing projects. Responsible for performance of preliminary soils and foundation investigations and field percolation testing. EDUCATION: DONALD M. MATTHEWS PROJECT ENGINEER B.S., Civil Engineering, California State Polytechnic University, Pomona, Cum Laude, Dean's List, President's List — June 1986 M.S., Civil Engineering, California State University, Long Beach — May 1991 MISC. Registered Civil Engineer: RCE 45956 MFMRF.R: PROFESSIONAL EXPERIENCE : Instructor of a Soil Mechanics, California State Poly— technic University, Pomona American Society of Civil Engineers Chi Epsilon Tau Beta Pi 1-89 to Present C.H.J., INCORPORATED Project Engineer Responsible for the preparation of Preliminary Soils, Foundation and Percolation reports, as well as special reports to deal with specific soil situations. This includes direct contact with the client, his consultants and involved public agencies. These situations require the coordination and direction of all necessary field work, including personnel and required equipment, and all necessary laboratory testing and analysis to develop relevant data. Also required is analysis of all data and laboratory results and the formation of conclusions and recommendations for this information. Such reports include recommendations for site grading, foundation design, slope stability, retaining walls, street structural section design and individual disposal system design, as well as recommendations to deal with any special or unusual conditions existing at the job site. In addition, other duties include periodic field observation of projects, as well as problem solving of day to day situa— tions inherent within on —going projects. PROFESSIONAL EXPERIENCE : Cont'd 4-86 to 1-89 C.H.J., INCORPORATED Staff Engineer Responsible for the preparation of Preliminary Soils, Foundation and Percolation reports, as well as special reports to deal with specific soil situations. This includes direct contact with the client, his consultants and involved public agencies. These situations require the coordination and direction of all necessary field work, including personnel and required equipment, and all necessary laboratory testing and analysis to develop relevant data. Also required is analysis of all data and laboratory results and the formation of conclusions and recommendations for this information. Such reports include recommendations for site grading, foundation design; slope stability, retaining walls, street structural section design and individual disposal system design, as well as recommendations to deal with any special or unusual conditions existing at the job site. In addition, other duties include periodic field observation of projects, as well as problem solving of day to day situa— tions inherent within on —going projects. BEN WILLIAMS STAFF ENGINEER EDUCATION: B.S., Geology, San Diego State University, San Diego, California - 1976 PROFESSIONAL EXPERIENCE : 11-89 to Present C.H.J., INCORPORATED Staff Engineer Responsible for the preparation of Preliminary Soils, Foundation and Percolation reports, as well as special reports to deal with specific soil situations. This includes direct contact with the client, his consultants and involved public agencies. These situations require the coordination and direction of all necessary field work, including personnel and required equipment, and all necessary laboratory testing and analysis to develop relevant data. Also required is analysis of all data and laboratory results and the formation of conclusions and recommendations for this information. Such reports include recommendations for site grading, foundation design, slope stability, retaining walls, street structural section design and individual disposal system design, as well as recommendations to deal with any special or unusual conditions existing at the job site. In addition, other duties include periodic field observation of projects, as well as problem solving of day to day situations inherent within on -going projects. 11-76 to 11-89 C.H.J., INCORPORATED Staff Geologist Responsible for performance of preliminary soils and foundation investigation; responsible for calculations and reporting of various tests to engineers; and responsible for field testing and report preparation with respect to field control of engineering projects. In addition, other duties included compaction testing, grading observation and percolation testing, as well as logging and sampling of soil trenches and borings for various projects. JOHN E. DALGITY OPERATIONS MANAGER EDUCATION: Graduate of Yucaipa High School Yucaipa, California Crafton Hills College, 2 years Liberal Arts University of California at San Bernardino, 1 Year History PROFESSIONAL EXPERIENCE : 6-89 to Present C.H.J., INCORPORATED Operations Manager Responsible for daily assignment of four field supervisors. Supervision of field directors and their daily assignments of field technicians. Responsible for laboratory supervisor and lab technicians work as it relates to the field. Responsible for assimilating and monitoring field data for technical reports and proposals for upcoming projects, interview and hiring of field technicians and six month performance reviews, radiation safety officer of nuclear density gauges, and for operation and safety program with field technicians. 1-86 to 6-89 C.H.J., INCORPORATED Field Director 4-76 to 1-86 Responsible for daily assignment of field technicians, preparation and review of technical reports, interviewing and hiring responsibilities for field technicians, radiation safety officer, nuclear density gauges, and for operation and safety program with field technicians. C.H.J., INCORPORATED Senior Engineering Technician Ten years experience performing field concrete tests, soils tests and grading observations. Performed laboratory soil tests and asphalt tests, and conducted preliminary soils and foundation investigations. EDUCATION: MFMRFR: PROFESSIONAL EXPERIENCE : WERNER VELASCO LABORATORY DIRECTOR B.S., Material Science and Engineering Cornell University, Ithaca, New York May 1983 American Institute of Metallurgical Engineers Venezuelan Society of University Superior Technicians 8-87 to Present C.H.J., INCORPORATED Laboratory Director Overall responsibility for the geotechnical laboratory operation. Assign tasks for laboratory personnel and perform laboratory tests as necessary. Implement and carry out quality control program for equipment and staff. Set up proce— dures for new tests. Interpret and report lab tests as appropriate. 12-83 to 12-86 CORPOVEN OF VENEZUELA OIL Laboratory Supervisor Designed and implemented the Laboratory of Materials and the metallography section of the Corrosion Laboratory. Physical, chemical, mechanical, metal— lographical, nondestructive, corrosion, and fatigue tests; effect of temperature in metals and ceramics. Evaluated the macro and micro —structure of different ferrous and nonferrous alloys. Inspections and testing of welds. Inspections in site of processes of manufacture. Wrote detailed reports and translated from Spanish to English and from English to Spanish. Familiar with ASME, SAE and ASTM Standards. 6-83 to 12-83 UNIVERSITARY INSTITUTE OF TECHNOLOGY Jaboratory Supervisor & Teacher Assistant Prepared and presented lectures in physical and mechanical metallurgy. Organized experiments and supervised students in the laboratory of metallography and the physical —mechanical testing laboratory. C. H. J., Incorporated is a California Corporation organized under the laws of the State of California. The authority to operate as a commercial laboratory is derived from the association with a Civil Engineer also licensed under the laws of the State of California. ORGANIZATION STRUCTURE C. H. J., INCORPORATED President and General Manager John L. Riddell Geotechnical Division Senior Vice President Robert J. Johnson Vice President Donald M. Matthews Construction Inspection DivisiQn Senior Vice President Robert L. Nottingham Vice President William Y. Liu Staff Engineers Field Dispatchers Field Technicians Laboratory Directors Field Dispatcher Laboratory Special Technicians Inspectors STANDARD FORM (SF) 254 1. Firm Name / Business Address: C.H.J., Incorporated 1355 East Cooley Drive Colton, California 92324 , • 1 a. Submittal is for Ll Parent Company 0 Branch or Subsidiary Office 2. Year Present Firm Established: 1964 3. Date Prepared: May 1992 4. Specify type of ownership and check below, if applicable. Corporation, California Architect -Engineer • and Related Services Questionnaire X A. §mljpusiness B. Small Disadvantaged Business C. Woman -owned Business 5: Name of Parent Company, if any: • N/A 5a. Former Parent Company Name(s), if any, and Year(s) Established: C.H.J. Materials Laboratory, Inc. - 1964 (Name Change 'Only) 6. Names of not more than Two Principals to Contact: Title / Telephone 1) Robert J. Johnson, Sr. Vice President / (714).824-7210 2) Robert L. Nottingham, Sr. Vice President / (714) 824-7210 7. Present Offices: City / State / Telephone / No. Personnel Each Office 7a. Total Personnel C.N.J., Incorporated 1355 East Cooley Drive Colton, California 92324. 67 8. Personnel by Discipline: (List each person only once, by primary function.) 4 Administrative Electrical Engineers Oceanographers • 21 Field & Lab Technicians Architects Estimators Planners: Urban/Regional 13 Deputy Inspectors Chemical Engineers Geologists Sanitary Engineers _1(1 Technical/Professional _1— 2 Civil Engineers Hydrologists Soils Engineers , 8 Office/Clerical Construction Inspectors Interior Designers Specification Writers 3 Draftsmen Landscape Architects Structural Engineers Ecologists Mechanical Engineers Surveyors Economists Mining Engineers Transportation Engineers 9. Summary of Professional Received: (Insert Direct Federal contract All other domestic All other foreign work` 'Firms interested in Services Fees index number) work, including overseas work foreign work, but without such experience, Last 5 Years (most recent year first) _ 19 91 19 90 19 89 19 88 19 87 Ranges of Professional Services Fees INDEX 1. Less than $100,000 2. $100,000 to $250,000 3. $250,000 to $500,000 4. $500,000 to $1 million 5. $1 million' to $2 million6. S2 million to S5 million 7. $5 million to $10 million 8. $10 million or greater - 1 1 1 1 1 6 6 6 6 6 check here: ■. Experience Profile Code Numbers for use with questions 10 and .11 001 Acoustics; Noise Abatement 002 Aerial Photogrammetry 003 Agricultural Development; Grain Storage; Farm Mechanization 004 Air Pollution Control 005 Airports; Navaids; Airport Lighting; Aircraft Fueling 006 Airports; Terminals & Hangars; Freight Handling 007 Arctic Facilities 008 Auditoriums & Theatres 009 Automation; Controls; Instrumentation 010 Barracks; Dormitories 011 Bridges 012 Cemeteries (Planning 8 Relocation) 013 Chemical Processing & Storage 014 Churches; Chapels 015 Codes; Standards; Ordinances • 016 Cold Storage; Refrigeration; Fast Freeze 017 Commercial Buildings (low rise); Shopping Centers 018 Communications Systems; TV; Microwave 019 Computer Facilities; Computer Service 020 Conservation and Resource Management 021 Construction Management 022 Corrosion Control; Cathodic Protection; Electrolysis 023 Cost Estimating 024 Dams (Concrete; Arch) 025 Dams (Earth; Rock); Dikes; Levees 026 Desalinization (Process & Facilities) 027 Dining Halls; Clubs; Restaurants 028 Ecological & Archeological Investigations 029 Educational Facilities; Classrooms 030 Electronics 031 Elevators; Escalators; People -Movers 032 Energy Conservation; New Energy Sources 033 Environmental Impact Studies, Assessments or Statements 034 Fallout Shelters; Blast -Resistant Design 035 Field Houses; Gyms; Stadiums 036 Fire Protection 037 Fisheries; Fish Ladders 038 Forestry & Forest Products 039 Garages; Vehicle Maintenance Facilities; Parking Decks 040 Gas Systems (Propane; Natural, Etc.) 041 Graphic Design 042 Harbors; Jetties; Piers; Ship Terminal . Facilities 043 Heating; Ventilating; Air Conditioning 044 Health Systems Planning 045 Highrise; Air -Rights -Type Buildings 046 Highways; Streets; Airfield Paving; Parking Lots 047 Historical Preservation 048 Hospital & Medical Facilities 049 Hotels; Models 050 Housing (Residential, Multi -Family; Apartments; Condominiums) 051 Hydraulics & Pneumatics 052 Industrial Buildings; Manufacturing Plants 053 Industrial Processes; Quality Control 054 Industrial Waste Treatment 055 Interior Design; Space Planning 056 Irrigation; Drainage 057 Judicial and Courtroom Facilities 058 Laboratories; Medical Research Facilities 059 Landscape Architecture 060 Libraries; Museums; Galleries 061 Lighting (Interiors; Display; Theatre, Etc.) 062 Lighting (Exteriors; Streets; Memorials; Athletic Fields, Etc.) 063 Materials Handling Systems; Conveyors; Sorters 064 Metallurgy 065 Microclimatology; Tropical Engineering 066 Military Design Standards 067 Mining & Mineralogy 068 Missile Facilities (Silos; Fuels; Transport) 069 Modular Systems Design; Pre -Fabricated Structures or Components 070 Naval Architecture; Off -Shore Platforms 071 Nuclear Facilities; Nuclear Shielding 072 Office Buildings; Industrial Parks 073 Oceanographic Engineering 074 Ordnance; Munitions; Special Weapons 075 Petroleum Exploration; Refining 076 Petroleum and Fuel (Storage and Distribution) 077 Pipelines (Cross -Country —Liquid 8 Gas) 078 Planning (Community, Regional. Areawide and State) 079 Planning (Site, Installation, and Project) 080 Plumbing & Piping Design 081 Pneumatic Structures; Air -Support Buildings 082 Postal Facilities 083 Power Generation, Transmission, Distribution 084 Prisons & Correctional Facilities 085 Product, Machine & Equipment Design 086 Radar; Sonar; Radio & Radar Telescopes 087 Railroad; Rapid Transit 088 Racreation Facilities (Parks, Marinas, Etc.) 089 Rehabilitation (Buildings; Structures; Facilities) 090 Resource Recovery; Recycling 091 Radio Frequency Systems & Shieldings 092 Rivers; Canals; Waterways; Flood Control 093 Safety Engineering; Accident Studies; OSHA Studies 094 Security Systems; Intruder & Smoke Detection 095 Seismic Designs & Studies 096 Sewage Collection, Treatment and Disposal 097 Soils & Geologic Studies; Foundations 098 Solar Energy Utilization 099 Solid Wastes; Incineration; Land Fill 100 Special Environments; Clean Rqoms, Etc. 101 Structural Design; Special Structures 102 Surveying; Platting; Mapping; Flood Plain Studies • 103 Swimming Pools 104 Storm Water Handling & Facilities 105 Telephone Systems (Rural; Mobile; Intercom, Etc.) 106 Testing & Inspection Services 107 Traffic & Transportation Engineering 108 Towers (Sell -Supporting 8 Guyed Systems) 109 Tunnels & Subways 110 Urban Renewals; Community Development 111 Utilities (Gas 8 Steam) 112 Value Analysis; Life -Cycle Costing 113 Warehouses & Depots 114 Water Resources; Hydrology; Ground Water 115 Water Supply, Treatment and Distribution 116 Wind Tunnels; Research/Testing Facilities Design 117 Zoning; Land Use Studies 201 •. 202 203 204 205 10. Profile of Profile Code 1) 033 2) 097 3) 106 4) 5) 6) 7) 8) 9) 10) Firm's Project Number of Projects 124 5,986 3,253 Experience, Last 5 Years Total Gross Fees (in thousands) 3,490 14,165 7,375 Profile Code 11) 12) 13) 14) 15) 16) 17) 18) 19) 20) Number of Projects Total Gross Fees (in thousands) • Profile Code 21) 22) 23) 24) 25) 26) 27) 28) 29) 30) Number of Projects Total Gross Fees (in thousands) 11. Project Examples, Last 5 Years Profile Code "P", "C", "JV", or "IE" • Project Name and Location Owner Name and Address Cost of Work (in thousands) Completion Date u, �t:t 097b 106 C 1 Contract N62474-83-C-2316 Geotechnical Engineering and Material Testing Services Various Locations in Southern Calif. Western Division Naval Facilities Engineering Command P. 0. Box 727, San Bruno, CA 94066 _ 140 1984 097b 106 C 2 Expansion of Main Exchange March Air Force Base, CA Dept. of the Army b The Air Force HQ, Army & Air Force Exchange Service Dallas, TX 75222 9.4 1985 097 C 3 San Bernardino GMF & VMF San Bernardino County near Redlands, CA United States Postal Service c/o RUHNAU MCGAVIN RUHNAU/ASSOCIATES 3775 Tenth St., -Riverside, CA 92501 44 1985 097& 106 C 4 Silver Lakes Development Helendale, CA Dart Resorts A Division of Dart Industries & MCO P 0 Box 3157 Terminal Annex Los Angeles, CA 90051 1000 On -Going 0978 106 C 5 FMO Building Addition New East Wing - Main Hospital Loma Linda, CA Loma Linda University Medical Center Loma Linda, CA 150 1986 097b 106 i C 6 Helendale Avionics Facility Helendale, CA Lockheed California Corporation P. 0. Box 551 Burbank, CA 400 1983& On -Going 9 097& 106 C 7 Fontana 2500 Commercial Fontana, Heritage West End Associates Acre Industrial Housing and Development CA _ Fontana Heritage West End Associates 6101 Cherry Avenue Fontana, CA 92335 100+ On -Going 091& 106 C 8 East Highlands Ranch, Inc. 1700 Acre Housing Development East Highlands Ranch, Inc. 3401 Centrelake Drive, Ste. 480 Ontario, CA 91764 3.3 1984 9 City of Moreno Valley City of Moreno Valley 097b C Testing & Insp. through Public Right- 23119 Cottonwood Avenue, Bldg. "B" 400+ On -Going 106 of -Ways, Street Improvements & Moreno Valley, CA 92388 Utility Installation 097& 106 C 10Geotechnical Engineering & Inspection for Various Projects in Southern. California Southern California Edison Company P. 0. Box 800 Rosemead, CA 91770 500+ 1985& On -Going 097& 106 C 11Surgery Unit Replacement Kaiser.Permanente Fontana, CA Kaiser Permanente 1515 North Vermont Avenue Los Angeles, CA 90027 60 19858 On -Going 097& 12Chino Hills Infrastructure County of San Bernardino 106 C Chino Area San Bernardino County, CA 150 097& 13Sycamore Canyon Master Plan T & S Development Company 106 C Toxic Materials Overview Riverside, CA 5225 Canyon Crest Drive Riverside, CA 150 1987& On -Going 091b 14Aircraft Runway. Rehabilitation Jet Propulsion Laboratories 106 C Goldstone, CA Pasadena, CA 5 1986 097b 15 Various Construction Projects Rohr Industries Facility Rohr Industries, Inc. 8200 Arlington Avenue 1986& 106 C Riverside, CA Riverside, CA 45 On -Going 091b 16Various Projects/Public Works City of San Bernardino "D" 106 C City of San Bernardino, CA 300 North Street San Bernardino, CA 92401 900+ 1964& On -Going 17 Seccombe Lake Park City of San Bernardino 033 San Bernardino, CA 300 North "D" Street 7.5 1989 C San Bernardino, CA 92418 1 U8 GT Investigation Larry Jacinto Construction 033 Redlands, CA P. O. Box 165 6.5 1989 C Mentone, CA 92359 19UGT Investigation County of Riverside 033 C Riverside, CA Department of Health 11.7 1989 3636 University Avenue Riverside, CA 92501 033 C 2OUGT & Waste Disposal Area Study San Bernardino, CA San Bernardino Water Department P. 0. Box 710 San Bernardino, CA 92402 6 (Estimated) 1990 097& 106 C 21E1 Toro Marine Corps Base El Toro, CA Delgado & Sons (CQC) P. 0. Box 457 Yucaipa, CA 92399 45 1989 097& 106 C 22Loma Linda Medical Center Building Additions Loma Linda, CA Loma Linda Medical Center 10935 Parkland Loma Linda, CA 92354 4 1989 097& 106 C 23Moreno Valley Hospital Moreno Valley, CA Hemet Valley Hospital District 1117 E. Devonshire Avenue Hemet, CA 92343 200& On -Going 1988& On -Going 097& 106 C 24Centennial High School Corona, CA Corona -Norco Unified School Dist. c/o Ruhnau Ruhnau Todd/Associates 3775 Tenth Street ,Riverside, CA 92501 54.2 1986 097& 106 C 25 Various School Sites within Corona -Norco Area Corona -Norco Unified School Dist. c/o PCH Associates 307 Brookside Avenue Redlands, CA 92373 37& On -Going 1987& On -Going 26 27 • 28 - 29 . 30 12. The Signature: for n i a I;St tement of facts -----' Typed Name and Title: Robert J. JQtuison,5s . Vice Pres. Date: May 28, 1992 4 : 1 Af111A1U11 (-MU 7%4 ink v 10 OH Cc • H • cJ • INCORPORATED P.O. Box 231 • 1355 East Cooley Drive, Colton, CA 92324 • Phone (909) 824-7210 11910 Hesperia Road, Suite 2 • Hesperia, CA 92345 • (619) 949-0006 August 11, 1993 City of Fontana P. O. Box. 518 Fontana, California 92335 Attention: Mr. Yusuf Patanwala Subject:. Compaction Report Street Finish Grade Baseline Avenue, West of Almeria Avenue Fontana, California Dear Mr. Patanwala: Job No. 93301-1 This report covers the results of in —place density tests taken to date on the street finish grade at the above referenced location. All tests were taken in coordination with and as requested by the client's representative. FIELD PROCEDURE: A total of 19 in —place density tests were taken by the sand volume method between July 8 and July 12, 1993. A representative sample of the soil encountered was returned to the laboratory for determination of the Optimum Moisture Content — Maximum Dry Density curve. SOILS ENGINEERS • MATERIALS TESTING AND EVALUATION • CONSTRUCTION INSPECTION C• L • j. Page No. 2 Job No. 93301-1 The locations of the in —place density tests are indicated on the attached Field Compaction Test Summary Sheet and Plat. OPTIMUM MOISTURE — MAXIMUM DENSITY RELATION: ASTM D 1557-78 Soil Optimum Moisture Maximum Dry Density Type Classification (Percent) (PCF) 1 Sandy Gravel, fine to medium, 8.5 132.5 with coarse; gravel to 3", brown (GP) RESULTS: The results of the in —place density tests taken to date, and the relative compaction in each case, are shown on the attached Field Compaction Test Summary Sheet. The test results presented herein represent an independent sample of the compaction achieved by the contractor who performed the actual compaction operation. Certain information concerning the. location of the street finish grade tested was furnished by persons representing themselves as knowledgeable of those conditions. In many cases, independent verification of that information furnished to us, or the knowledge of that information by any person representing themselves as knowledgeable, is not possible. That information is relied upon during the performance of these tests. �C . • �l Page No. 3 Job No. 93301-1 Compaction testing by our firm in no way relieves the contractor from his obligation to properly perform his work, and this report does not serve as a warranty of the contractor's work or of the information supplied to us by the contractor. Respectfully submitted, C.H.J., INCORPORATED tanjali Kanchi, Staff Engineer Robert J. Johnson, G.E. 443 Senior Vice President GJM/GK/RJJ:tlh Enclosures: Field Compaction Test Summary Sheet Plat Distribution: City of Fontana (4) FIELD COMPACTION TEST SUMMARY SHEET PROJECT: CITY OF FONTANA - STREET FINISH GRADE, BASELINE AVENUE, WEST OF ALMERIA AVENUE, FONTANA, CALIFORNIA Job No Sh 93301-1 1 of Date Test No. Location Of Test Depth Cut Of Fill Depth Of Test DENSITIES MC% Soil Type Remarks or Retest Of Dry Max. Rel. (Ibs/cubic foot) 7-08-93 FG-1 Baseline Avenue, Station 10+25, Main 0.0-0.5 132.2 138.0 96 6.1 1 20% RX FG-2 Baseline Avenue, Station 12+75, Main 0.0-0.5 141.2 142.0 99 7.0 1 35% RX FG-3 Baseline Avenue, Station 15+25, Main 0.0-0.5 130.6 135.0 97 6.3 1 10% RX FG-4 Baseline Avenue, Station 17+75, Main 0.0-0.5 134.3 139.5 96 5.9 1 25% RX FG-5 Baseline Avenue, Station 20+25, Main 0.0-0.5 134.7 137.0 98 6.6 1 15% RX FG-6 Baseline Avenue, Station 22+75, Main 0.0-0.5 132.1 139.5 95 6.0 1 25% RX FG-7 Baseline Avenue, Station 25+25, Main 0.0-0.5 131.1 137.0 96 5.8 1 15% RX FG-8 Baseline Avenue, Station 27+75, Main 0.0-0.5 134.0 141.0 95 6.0 1 30% RX FG-9 Baseline Avenue, Station 30+25, Main 0.0-0.5 140.0 139.5 100+ 8.0 1 25% RX FG-10 Baseline Avenue, Station 32+75, Main 0.0-0.5 141.6 142.0 99 8.6 1 35% RX FG-11 Baseline Avenue, Station 35+25, Main 0.0-0.5 133.0 138.0 96 6.7 1 20% RX FG-12 Baseline Avenue, Station 37+75, Main 0.0-0.5 134.3 137.0 98 7.2 1 15% RX FG-13 Baseline Avenue, Station 40+25, Main 0.0-0.5 131.8 138.0 96 6.3 1 20% RX 7-09-93 FG-14. Baseline Avenue, Station 42+25, Main 0.0-0.5 145.4 142.0 100+ 8.6 1 35% RX 7-12-93 FG-15 Baseline Avenue, Station 10+00, Lateral 0.0-0.5 138.7 139.5 99 6.5 1 25% RX FG-16 Baseline Avenue, Station 16+35, Lateral 0.0-0.5 137.4 139.5 98 8.0 1 25% RX FG-17 Baseline Avenue, Station 29+01, Lateral 0.0-0.5 140.0 144.5 97 7.5 1 40% RX FG-18 Baseline Avenue, Station 36+51, Lateral 0.0-0.5 132.8 137.0 96 . 6.0 1 20% RX FG-19 Baseline Avenue, Station 42+70, Lateral 0.0-0.5 134.8 139.5 97 6.5 1 25% RX LEGEND: (SG) Tests on Subgrade Elevation; (BF) Tests on Backfill; (FP) Tests on Fill in Progress (FG) Tests on Finish Grade Elevation; (Mc) Moisture Content; (REL) Relative; (RX) Rock Corrected; (*) Denotes Failure Scale:1'=150' R/W(TyP.)\ 281-00 29t00 1 8+00- 7+00- 6+00 1-_; CC U 1n 0— CC 5+00 W U 4+00- Zx00- M Clz ALMERIA 26+00- 25+00- 24+00- Cd O cc 23+00- j 22+00- 21+00- CC ( kL. / jr pe% / MATCHLINE 20+00 19+00- 18+00- 17+00- SEWERL1NE (Typ.) 16+00- 15+00 - 14+00- 13+00- 12+00- 41 qP�x 30t00 31+100 32100 i 3� 00 34t00 35i00 36t00 37 t 00 38t00 39t 00 40?- 00 41 t OO 42+ 00 MATCHLINE 20+00 SEWERLINE (Typ. BASELINE AVE. 1 19 ✓ R/W(Typ.) MONTECA DR. / MARIPOSA DR. cd i ALMERIA LIME AVE. 10 i00 11+00 12 +00 1300 14+00 15+00 16 )00 17 +00 16 -00 19 100 20100 21 t00 22t00 23t00 24400 25t 00 26t00 t 5XI BEECH AVE. 18+11•1'.- IN¢ LULU ZZ 6 \ =W f<m BASELINE SULTANA AVE. AVE. FINISH GRADE TESTS 0 JOB NUMBER 0 N M 01 W N CO ro .CS U- 4- 0 M 01 01 W C) 2 U Z i*. T.il • INCORPORATED P.O. Box 231 • 1355 East Cooley Drive, Colton, CA 92324 •. Phone (909) 824-7210 11910 Hesperia Road, Suite 2 • Hesperia, CA 92345 • (619) 949-0006 August 11, 1993 City of Fontana P. O. Box 518 Fontana, California 92335 Attention: Mr. Yusuf Patanwala Subject: Compaction Report Sewer Trench Backfill Baseline Avenue and Almeria Avenue Trunk Sewer System Fontana, California Dear Mr. Patanwala: Job No. 93301-1 This report covers the results of in —place density tests taken to date on the sewer trench backfill at the above referenced location. All tests were taken. in coordination with and as requested by the client's representative. FIELD PROCEDURE: A total of 19 in —place density tests were taken by the sand volume method between May 11 and July -1, 1993. A representative sample of the soil encountered was returned to the laboratory for determination of the Optimum Moisture Content — Maximum Dry Density curve. SOILS ENGINEERS • MATERIALS TESTING AND EVALUATION • CONSTRUCTION INSPECTION • • uJ • Page No. 2 Job No. 93301-1 The locations of the in —place density tests are indicated on the attached Field Compaction Test Summary Sheet and Plat. OPTIMUM MOISTURE — MAXIMUM DENSITY RELATION: ASTM D 1557-78 Soil Optimum Moisture Maximum Dry Density Type Classification (Percent) (PCF) 1 Sandy Gravel, fine to medium, 8.5 132.5 with coarse; gravel to 3", brown (GP) RESULTS: The results of the in —place density tests taken to date, and the relative compaction in each case, are shown on the attached Field Compaction Test Summary Sheet. The test results presented herein represent an independent sample of the compaction achieved by the contractor who performed the actual compaction operation. Certain information concerning the depth and location of the sewer trench backfill tested was furnished by persons representing themselves as knowledgeable of those conditions. In many cases, independent verification of that information furnished to us, or the knowledge of that information by any person representing themselves as knowledgeable, is not possible. That information is relied upon during the performance of these tests. . j. Page No. 3 Job No. 93301-1 Compaction testing by our firm in no way relieves the contractor from his obligation to properly perform his work, and this report does not serve as a warranty of the contractor's work or of the information supplied to us by the contractor. Q4oE� SS1o'. co 45" otit, F� 0 u a No. 443 i EXPIRATION DATE r 3-31.97 �v GJM/GK/RJJ:tlh Respectfully submitted, C.H.J., INCORPORATED i Gjtanjali Kanchi, Staff Engineer 7 Rotleik J. Johnsoi,'G.E. 443 Senor Vice Presi nt Enclosures: Field Compaction Test Summary Sheet Plat Distribution: City of Fontana (4) FIELD COMPACTION TEST SUMMARY SHEET PROJECT: CITY OF FONTANA - SEWER TRENCH BACKFILL, BASELINE AVENUE AND ALMERIA AVENUE, TRUNK SEWER SYSTEM, FONTANA, CALIFORNIA Job No Sh 93301-1 1 of 1 Date Test No. Location Of Test Depth Cut Of Fill Depth Of Test DENSITIES MC% Soil Type Remarks or Retest Of Dry Max. Rel. (Ibs/cubic foot) 5-11-93 BF-1 Almeria Avenue, Station 14+25 17.0 8.0 3.0-3.5 115.4 138.0 84 7.0 1 25% RX •• 5-12-93 BF-2 Almeria Avenue, Station 16+75 16.0 8.0 2.5-3.0 124.9 144.0 87 9.0 1 42% RX " 5-13-93 BF-3 Almeria Avenue, Station 19+50 18.0 10.0 3.0-3.5 151.1 138.5 100+ 9.9 1 25% RX 5-14-93 BF-4 Almeria Avenue, Station 22+25 18.0 6.0 3.0-3.5 118.0 142.5 83 10.0 1 35% RX ** 5-18-93 BF-5 Almeria Avenue, Station 24+75 16.0 13.0 3.0-3.5 135.6 141.0 96 9.1 1 35% RX 13F-6 Almeria Avenue, Station 26+35 • 16.0 13.0 3.5-4.0 137.3 145.0 95 9.5 1 43% RX 5-19-93 I3F-7 Almeria Avenue, Station 1+30 14.0 14.0 3.5-4.0 142.2 144.0 99 10.3 1 40% RX 5-24-93 13F-8 Almeria Avenue, Station 7+00 16.0 16.0 3.5-4.0 137.5 141.0 98 8.6 1 30% RX 13F-9 Almeria Avenue, Station 11+00 15.0 15.0 4.0-4.5 136.0 138.0 98 4.5 1 20% RX 6-17-93 13F-10 Baseline Avenue, Station 15+25 17.0 7.0 1.0-1.5 132.9 143.0 93 9.0 1 34% RX BF-11 Baseline Avenue, Station 12+00 17.0 17.0 3.0-3.5 129.8 135.0 96 9.2 1 10% RX 6-18-93 BF-12 Baseline Avenue, Station 17+75 17.0 8.0 1.0-1.5 129.0 144.0 90 7.9 1 40% RX 6-22-93 BF-13 Baseline Avenue, Station 25+00 17.0 10.0 2.0-2.5 135.5 141.0 96 9.0 1 30% RX BF-14 Baseline Avenue, Station 20+80 . 17.0 17.0 1.0-1.5 126.2 135.0 94 7.0 1 10% RX 6-23-93 BF-15 Baseline Avenue, Station 27+75 17.0 10.0 1.0-1.5 128.9 141.0 91 7.4 1 30% RX 6-25-93 BF-16 Baseline Avenue, Station 34+00 17.0 11.0 1.0-1.5 130.3 141.0 92 9.6 1 30% RX BF-17 Baseline Avenue, Station 30+50 17.0 17.0 3.0-3.5 140.3 148.0 95 8.7 1 55% RX 6-29-93 BF-18 Baseline Avenue, Station 38+00 17.0 14.0 2.0-2.5 132.0 139.5 95 8.6 1 25% RX 7-01-93 BF-19 Baseline Avenue, Station 40+50 17.0 17.0 3.0-3.5 129.0 139.5 93 8.0 ' 1 25% RX LEGEND: (SG) Tests on Subgrade Elevation; (BF) Tests on Backfill; (FP) Tests on Fill in Progress (FG) Tests on Finish Grade Elevation; (Mc) Moisture Content; (REL) Relative; (RX) Rock Corrected; (*) Denotes Failure (**) Denotes Failure, No Retest Requested Scale:1'=150' R/W(TyP.)\ 28100 29t00. I 8+00- 7+00- CC 5+00 W 0 4+00- ce o 0` 3+00 WALNUT ST. iM'9T o 6q4 ., glcx 30t00 31+100 32 1'00 ~% 3� 00 34+00 35t00 36t00 37t 00 38t00 39t 00 40t 00 41 00 42� 00 26+00- 25+00- 24+00- 23+00- 22+00- Q 0 cc — 21+00- CC 0 MATCHLINE 20+00 WINCHESTER CRT. 19+00- 18+00- 17+00- SEWERLINE .(Typ.) 16+00- 15+00 - 14+00- 13+00- 12+00- MATCHLINE 20+00 16 BASELINE SEWERLINE (Typ. AVE. ,r R/W(Typ.) MONTECA DR. MARIPOSA DR. ce 0 cc 0 i ALMERIA -11+00 LIME AVE. 10 r0 11#00 12 100 13 i00 14100 15 +00 16100 17 +00 18+100 19 100 20100 21t00 22 00 23t00 24t00 25t 00 26t00 BEECH AVE. BASELINE SULTANA AVE. AVE. J ENCLOSURE FONTANA, CALIFORNIA LL M 01 01 0 BACKFILL TESTS