HomeMy WebLinkAbout5847-LTGENERAL NOTES FOR STREET LIGHT PLANS 1. LIGHTING LAYOUT SHALL COMMENCE AT STREET INTERSECTIONS. STREET LIGHT SPACING BETWEEN INTERSECTIONS SHALL BE AS SPECIFIED IN THE TABLE ON SHEET ' 3 AND LOCATED AT THE PROLONGATION OF THE PROPERTY LINES. STREET LIGHT LAYOUTS SHALL BE REVIEWED FOR CONFLICTS WITH OTHER UTILITIES (CATCH BASINS, FIRE HYDRANTS, TRANSFORMERS, ETC.) 2. USE OF BRAND NAMES IN THESE STANDARDS IS NOT INTENDED TO RESTRICT COMPETITION. EQUIVALENT PRODUCTS MAY BE SUBSTITUTED WITH THE APPROVAL OF THE CITY ENGINEER. J. SIDEWALK WIDTHS TO BE PER APPROVED STREET IMPROVEMENT PLANS. A MINIMUM OF 4' UNOBSTRUCTED SIDEWALK CLEARANCE IS REQUIRED. 4. ANY CHANGE IN LOCATION OF STREET LIGHTS FROM THE APPROVED PLANS OR STANDARDS IS SUBJECT TO WRITTEN APPROVAL BY THE CITY ENGINEER. 5. ALL STREET LIGHTS SHALL HAVE AN ANTI -GRAFFITI COATING LEGEND AND QUANTITIES O1 � INSTALL 41 W LED LUMINA/RE COBRAHEAD PER CITY STANDARD PLAN NO. 404 (CASE 1) - 1 EA CH �-- INDICATES FIRE HYDRANT REMOVE EXISTING SCE POWER POLE - 1 EACH (UNDERGROUND POWER LINE BY SCE) O O INSTALL LED STREET LIGHT (STANDARD COBRAHEAD) - 1 EACH 41 WATT (CASE 2) PER CITY STD. #404. r CITY OF FONTANA STREET LIGHT PLAN TRACT MA 1897 z W LL_ o 4< 0 W z 0 15 30 60 90 SCALE: 1 "-30' SUMMIT AVE. CURTIS AVE. W j � Q SITE Q 0 o SIERRA LAKE PARKWAY VICINITY MAP N.T.S. MCN 14-028, DRP 18-025, TTM 14-002EX 1