HomeMy WebLinkAbout5847-LTGENERAL NOTES FOR STREET LIGHT PLANS
1. LIGHTING LAYOUT SHALL COMMENCE AT STREET INTERSECTIONS. STREET LIGHT SPACING
BETWEEN INTERSECTIONS SHALL BE AS SPECIFIED IN THE TABLE ON SHEET ' 3
AND LOCATED AT THE PROLONGATION OF THE PROPERTY LINES. STREET LIGHT LAYOUTS SHALL BE
REVIEWED FOR CONFLICTS WITH OTHER UTILITIES (CATCH BASINS, FIRE HYDRANTS,
TRANSFORMERS, ETC.)
2. USE OF BRAND NAMES IN THESE STANDARDS IS NOT INTENDED TO RESTRICT COMPETITION.
EQUIVALENT PRODUCTS MAY BE SUBSTITUTED WITH THE APPROVAL OF THE CITY ENGINEER.
J. SIDEWALK WIDTHS TO BE PER APPROVED STREET IMPROVEMENT PLANS. A MINIMUM OF 4'
UNOBSTRUCTED SIDEWALK CLEARANCE IS REQUIRED.
4. ANY CHANGE IN LOCATION OF STREET LIGHTS FROM THE APPROVED PLANS OR STANDARDS IS
SUBJECT TO WRITTEN APPROVAL BY THE CITY ENGINEER.
5. ALL STREET LIGHTS SHALL HAVE AN ANTI -GRAFFITI COATING
LEGEND AND QUANTITIES
O1 � INSTALL 41 W LED LUMINA/RE COBRAHEAD
PER CITY STANDARD PLAN NO. 404 (CASE 1) - 1 EA CH
�-- INDICATES FIRE HYDRANT
REMOVE EXISTING SCE POWER POLE - 1 EACH
(UNDERGROUND POWER LINE BY SCE)
O O INSTALL LED STREET LIGHT (STANDARD COBRAHEAD) - 1 EACH
41 WATT (CASE 2) PER CITY STD. #404.
r
CITY OF FONTANA
STREET LIGHT PLAN
TRACT MA 1897
z
W
LL_
o
4<
0
W
z
0 15 30 60 90
SCALE: 1 "-30'
SUMMIT AVE.
CURTIS AVE.
W j
�
Q
SITE
Q
0
o
SIERRA LAKE
PARKWAY
VICINITY MAP
N.T.S.
MCN 14-028, DRP 18-025, TTM 14-002EX 1