HomeMy WebLinkAbout5891CITY OF FONTANA SEWER IMPROVEMENT NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTIONS ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTORS SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEERS FOR RESOLUTION. 3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK /N PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON - METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 7. THE CONTRACTORS SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-277-2600 TWO WORKING DAYS BEFORE EXCAVATION. 11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 13. STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT WHERE OTHERWISE NOTED. 14. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADE(S). THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 15. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 16. REMOVAL AND REPLACEMENT OR EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 17. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESS AT ALL TIMES. A MINIMUM 12 FOOT LAND SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 18. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 19. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT, OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 20. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 21. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION, FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 22. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 23. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE. 24. IF SEWER CONSTRUCTION IS TO BE DONE 1N PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE DOWNSTREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUTT, 25. SANITARY SEWER LINES SHALL BE CONSTRUCTEDMOF BELL AND SPIGOT OR BAND SEAL TYPE VETRIFIED CLAY PIPE (V. C. P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION C700 FOR V.C.P. 26. NO OPEN TRENCHES SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER. 27. SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT. 28. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOVCATIONS SHOWN ON THE PLANS. 29. ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT 2q MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER. 30. TERMINATE ALL 4" HOUSE LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12" BELOW THE GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT OF WAY, THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT. 31. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER LATERAL. 32. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY. 33. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. Rtcowgimfl PARCEL MAP 20069 A40we ����illillillillillillillilir4:)U.EA CONTINUATION - SEWER IMPROVEMENT NOTES 34. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF ? J STREETS. 35. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO N v PLACEMENT. m 36. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVES BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONSTRACTOR UPON COMPLETION OF PAVING. ROUGH GRADING. 37. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 38. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. UTILITY CONTACTS ELECTRICITY WATER SEWER SOUTHERN CALIFORNIA EDITON COMPANY FONTANA WATER COMPANY CITY OF FONTANA 300 N. PEPPER AVE. 8440 NUEVO AVENUE 8353 SIERRA AVENUE RIALTO CA. 923iog FONTANA, CA. 92335 FONTANA, CA. 92335 UNDERGROUND •09 357- 6233 ATTN. MICHAEL McGRAW (909) 350- 6632 TRANSMISSION 875-5100 (909) 822-2201 PIPELINES: (909) 657-1233 FAX (909) 283-5046 DISTRIBUTION: (909) 357- 6233 GAS SOUTHERN CALIFORNIA GAS CO. 1981 LUGONIA AVENUE REDLANDS, CA. 92374 ATT'N: JOHN OATES EMERGENCIES: (800) 427-2200 ENGINEER'S NOTE: GENERAL TELEPHONE COMPANY 1400 E. PHILLIPS RANCH BLVD, ONTARIO, CA. 91766 ATT'N: STEVE HOCK (800) 422-4133 COMCAST CABLEVISION 1205 DUPONT AVENUE ONTARIO, CA. 91761 ATT'N: JACK HAYES (909) 390-4738 THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES, CONDUITS OR ANY OTHER STRUCTURES SHOWN ON THESE DRAWINGS WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO OTHER UTILITIES OR STRUCTURES EXCEPT AS SHOWN ON THESE DRAWINGS. THE CONTRACTOR 1S REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THE DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS. CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, AND THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE COUNTY, THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. NO PAVING PAVING -VARIES v vv v v v v ,vBASE-VARIES vvvvvvvvi � bfllll� Jor:� Nmrn(Z 12" SAND 6" LIFT PIPE SIZE PER PLAN 6" SAND 6" PIPE 6" PER PLAN WATER/SEWER TRENCH DETAIL N. T.S. NOTES: 1. BACKFILL SHALL BE 90% RELATIVE COMPACTION BY TAMPING AT 6" LIFT 2. SAND BACKFILL AND BEDDING SHALL CLEAN WITH NO ASHES, CINDERS, REFUSE, ORGANIC MATTER, OR OTHER COROSSIVE MATERIALS. CONSTRUCTION NOTES: FOOTHILL BLVD. Q j ARROW BLVD. Q o SITE Q v g o J MERRILL AVE. VICINITY MAP N. T. S. SHEET INDEX SHEET 1 OF 2 = GENERAL NOTES SHEET 2 OF 2 = PLAN OR PROFILE FL = FLOWLINE ELEVATION TC = TOP OF CURB ELEVATION (X) = EXISTING ELEVATION TP = TOP OF PAVEMENT W = WATER LINE S = SEWER LINE G = GAS LINE FS = FINISHED SURFACE O CONSTRUCT 8" EXTRA STRENGTH VETRIFIED CLAY PIPE (V. C. P.) SEWER MAIN 2O CONSTRUCT STANDARD CAST IN PLACE 48" MANHOLE PER CITY STANDARD NO. 2001 30 CONSTRUCT 4" VCP SEWER LATERAL AND HOUSE CLEANOUT PER CITY STANDARD NO. 2005 ® CORE AND CUT THROUGH EXISTING MANHOLE AND RE -CHANNEL EXISTING CONCRETE SHELF 50 REMOVE AND REPLACE TRENCH AND EXISTING A.C. PAVING PER CITY STD. NO. 1008 © CONSTRUCT CONCRETE SEWER CLEANOUT BOX PER CITY STANDARD NO. 2006 BASIS OF BEARINGS IS THE CENTERLINE OF ARROW BOULEVARD BEING N89°59'45"E PER RS 142186 ESTIMATED QUANTITIES 142 L. F. 1 EACH 3 EACH 1 EACH 719 S.F. 3 EACH 17+00 PROFILE SCALE VERT: 1 in = 2 ft HORZ: 1 in = 20 ft CONSTRUCTION NOTES: O CONSTRUCT 8" EXTRA STRENGTH VETRIFIED CLAY PIPE (V.C.P.) SEWER MAIN 2O CONSTRUCT STANDARD CAST IN PLACE 48" MANHOLE PER CITY STANDARD NO. 2001 O3 CONSTRUCT 4" VCP SEWER LATERAL AND HOUSE CLEANOUT PER CITY STANDARD NO. 2005 ® CONNECT TO EXISTING STUB -OUT 5O REMOVE AND REPLACE TRENCH AND EXISTING A.C. PAVING PER CITY STD. NO. 1008 © CONSTRUCT CONCRETE SEWER CLEANOUT BOX PER CITY STANDARD NO. 2006 E� �0• �0x00 5x ,�0 n 18+00 _ N89'S914511E UNDERGROUND SERVICE ALERT CALL:TOLL FREE 1-800 227-2600 TWO WORKING DAYS BEFORE YOU DIG i 0 10 20 40 60 I III I III SCALE: 1 "=20' ( I) I � i II RIGHT OF WAY - — — — — — — — — — — — — — — — — — — — — — — — — — — — — —— — — — — — — — — — EX. SIDEWALK i — — — — — — — — — — — — — - — — — — — — — — — — — — — _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ EX. CURB/GUTTER I it I ARROW BOULEVARD M Z Lo _�I_—_�— —_ —_---EX._CUl�3i4GUTT-ER —- — w - - - - - - - - - - - EX. SIDEWALK DRI— VEWAY DRIVEWAY EX. SIDEWALK — — — — — — — — — — — — — — — — — — — — — — — — — — GUY WIRE NN89`59'45"E 141.65' RIGHT OF WAY �39 �> REV 65.00' O m PARCEL 1 PM 20069 0 REVISION DESCRIPTION 11 + + CO 19 (N RIGHT OF WAY — j _ t ) 1 101.79' t 1 --i;,7' WIDE SEWER EASEMENT N 0 PARCEL 2 PM 20069 20+00 0� PJE. 93 F � RE ! �9k 05 ZOk i Sir I n �,x \\20 X0O X06 C)J � W PPq! i W o D C) Z Z a 12' I jo' D < I DATE ENGR. CITY JDATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. rF�\ �----------- I I I I I I BENCH MARK: CITY BM # 516 DESCRIPTION: PK NAIL AT ECR NW COR OF LAUREL AVENUE AND ARROW BLVD. ELEV. = 1268.82 Prepared Under The Supervision Of: QROFESS/pN HENRY C. POOUIZ HP ENGINEERING, INC. 1465 CRESTVIEW ROAD w No.37037 m REDL IDS, CA. 92374 (909) 3 - 239, FAX (909) 335-9940 tc Exp. 6-30-20 C/v� �P CA0V ATE: 1 1 20 19 HENRY C. POQUI . E. 37037 BASIS OF BEARINGS IS THE CENTERLINE OF ARROW BOULEVARD BEING N89'59'45"E PER RS 142186 CITY OF FONTANA, CALIFORNIA STREET IMPROVEMENT PLAN SAWN BY: SCALE: CADD PARCEL MAP 20069 AS SHOWN SIGNED BY: DATE: HCP ARROW BOULEVARD 11/20/19 AECKED BY: A PROV BY y� �/ DRAWING No. 2 HCP DAT : 5891 2 CITY ENGINEER R.C. 1152