Loading...
HomeMy WebLinkAbout5870-7SIMILAR PATTERN IS TO 8E USED TC TC �---- SEE PLANS FOR MEDIAN WIDTH NOTE: a� WHERE CURB ELEVATIONS VARY INSTALL TO DRAIN TO LOW CURB. SEE OE17AIL A --` � 1" CONCRETE GAP BETWEEN ROCKS 1" CONCRETE GAP BETWEEN --fi ROCKS AND BACK OF CURB /�I /SET ROCK TO FULL DEPTH N CONCRETE BED j f WITH REQUIRED 1 "- I.5"EXPOSURE ABOVE TC. f t f WIRE BRUSH FINISH JOINTS BETWEEN ROCKS ROCK HEIGHT % J / r 6" MIN. PEA GRAVEL CONCRETE BED 1"-L5" INCH ABOVE TC rr +t DETAIL A 1� ' i tL-••�L"�-yJ' - NOT TO SCALE FOR ILLUSTRATIVE PURPOSES ONLY 80% MIN. COMPACTED SUBGRAOE OR BASE MATERIAL PER PLANS AND SPECS, 1- ROCK SIZES UNLESS OTHERWISE SPECIFIED SHALL BE: COBBLESTONES: MAX. 12" TO MIN. 6" , NO MORE THAN 50%OF ANY ONE SIZE. 2. A SAMPLE AREA, MIN. 10 SO, FT, SHALL BE APPROVED BY THE CITY INSPECTOR PRIOR TO PROCEEDING WITH THE REMAINING ROCK WORK. 3. FINAL RESTING POSITION OF ALL ROCKS SHALL BE APPROVED BY THE CITY INSPECTOR, 4. ROCKS SHALL BE SMOOTH, HOUNDED, FREE OF OBJECTIONABLE DISFIGURATIONS AND IRON CONTENT AS APPROVED BY THE CITY INSPECTOR 5. CONCRETE SHALL BE CLASS 520-G2500, 4 INCH SLUMP CONCRETE. 6. WIRE BRUSH ALL JOINTS AFTER THE INSTALLATION OFTHE ROCKS. AFTER CONCRETE HAS SET, CLEAN THE RESIDUE FROM SURFACES OF ROCKS. 7. NO JOINTS GREATER THAN 1" BETWEEN ROCKS WILL BE ACCEPTABLE. 4" FILLER ROCKS WILL BE ACCEPTED TO MAINTAIN THE 1" JOINT. 8. WHERE ROCK BORDERS TURF AREA, PLACE V CONCRETE EDGE BETWEEN BACK OF ROCK AND TURF, CITY OF FONTANA No.51152 dITY ENGINEER DATE TYP. ROCK TREATMENT RICARDO SANDOVAL EXP.9MI95 REVIEWED BY: _Timnt Rnstadt CIVIL a f 0 CALI�a DATE OF LAST REVISION: 1-28-00 STD. PLAN NO. 5045 SHT i OF I PLALNTIN& NOTES 1. THE PLANTING PLAN 15 DIAGRAMMATIC TO THE EXTENT THAT ALL PLANT LOCATIONS ARE SUBJECT TO ADJU5TMENT5 IN THE FIELD BY THE LAND5CAPE ARCHITECT, AND SUBSTITUTION OF PLANTS MAY BE MADE BY THE LANDSCAPE ARCHITECT (OR BY THE CONTRACTOR 5UBJECT TO APPROVAL BY THE LANDSCAPE ARCHITECT), DEPENDING ON AVAILABILITY, PHYSICAL CONDITION OR HEALTH OF THE PLANTS, OR FOR HORTICULTURAL, MICRO -CLIMATIC AND/OR AESTHETIC REASONS. 2. MAINTAIN ALL WORK SHALL CONFORM TO INDUSTRY STANDARDS AND LOCAL BUILDING CODES. PERMITS WHEN NECESSARY ARE THE RESPONSIBILITY F THE CONTRACTOR OR PROPERTY O E L L O R PE WN R. 3. IF ANY DISCREPANCIES OCCUR BETWEEN QUANTITIES OF PLANTS SHOWN IN THE PLANT LEGEND(5) AND QUANTITIES OF PLANTS 5HOWN ON THE PLAN DRAWINGS, THE DRAWINGS TAKE PRECEDENCE OVER THE PLANT LEGEND(5). CONTRACTOR 15 RESPONSIBLE FOR QUANTITY TAKE -OFFS BASED ON THE PLAN DRAWINGS. 4. APPLY A CONTACT HERBICIDE IF NECESSARY TO CONTROL WEED GROWTH PRIOR TO PLANTING OPERATIONS. SUBMIT PRODUCT RECOMMENDATION(5) TO THE LANDSCAPE ARCHITECT FOR APPROVAL PRIOR TO PROCUREMENT AND APPLICATION OF THE PRODUCT 5. SEND 5AMPLE-5 OF EXISTING SOILS TO WALLACE LABS N5.WLAB5.00M), OR 51MILAR EQUALLY -QUALIFIED 501L TESTING LABORATORY, FOR 501L ANALYSES AND RECOMMENDATION5 REGARDING 501L AMENDMENTS. SUBMIT 501L MANAGEMENT REPORT TO LANDSCAPE ARCHITECT PRIOR TO PROCUREMENT OF AMENDMENTS AND TILLING OPERATIONS. 6. NURSERY STOCK SHALL MEET CURRENT STANDARDS OF THE AMERICAN STANDARD FOR NURSERY STOCK (ANSI Z60.10 REGARDING CONTAINER SIZE, PHYSICAL CONDITION OF PLANTS AND OTHER CRITERIA THAT PERTAIN TO THE QUALITY OF NURSERY STOCK. ENSURE THAT PURCHASED PLANT MATERIAL HAD BEEN PROPERLY GROWN AND SHIFTED, AND THAT IT 15 PROPERLY HANDLED DURING THE DELIVERY PROCESS. T. FULLY SCARIFY THE BOTTOM AND SIDES OF PLANTING PITS AND HOLES PRIOR TO INSTALLATION OF PLANTS TO REMOVE ALL EVIDENCE OF GLAZING BY EXCAVATION EQUIPMENT. DEEPLY FRACTURE COMPACTED, SILTY, OR CLAYEY SUBSOILS, HARDPAN AND ANY OTHER 501L CONDITION WITHIN PLANTING PITS THAT WOULD IMPEDE GROWTH OF PLANT ROOTS. 8. PRIOR TO PLANTING OPERATIONS, PROPERLY REMOVE ALL REMNANT CONCRETE FOUNDATIONS, PADS, WALL5, COLUMNS AND ANY OTHER MATERIALS THAT MAY BE DELETERIOUS TO THE HEALTHY GROWTH OF PLANTS AND THEIR ROOT SYSTEMS. 4. EXTEND LATERAL EXCAVATION OF PLANTING PITS WELL BEYOND THE DIMENSIONS OF THE PLANT CONTAINER, THE EXTENT DEPENDING ON 501L TEXTURE. COARSE -TEXTURED SOILS REQUIRE LE55 EXCAVATION, FINE -TEXTURED 501L5 REQUIRE GREATER EXCAVATION, ESPECIALLY IN THE UPPER 12A TO 24A OF GRADE. 10. ENSURE THAT THE BOTTOM OF TREE PITS 15 EITHER UN -EXCAVATED OR SUFFICIENTLY COMPACTED AND STABLE TO PREVENT SUBSEQUENT SETTLEMENT OF THE TREE. 11. ENSURE THAT ALL PLANT PITS ARE FREE -DRAINING PRIOR TO PLANTING. 12. INSTALL ALL PLANTS AT PROPER ELEVATION WITH RESPECT TO FINISH GRADE. ENSURE THAT THE ROOT GROWN OF TREES 15 PLANTED SLIGHTLY ABOVE GRADE AND THAT GIRDLING ROOTS ARE NOT PRESENT. 13. BAGKFILL PLANTS WITH NATIVE OR AMENDED 501L A5 NECESSARY TO PROMOTE LONG-TERM GROWTH AND HEALTH OF THE PLANT. REMOVE AIR POCKETS AND PROPERLY COMPACT BAGKFILL. 14. MAINTAIN ALL PLANTINGS ON A DAILY OR WEEKLY BASIS AS NEGE55ARY FOR A PERIOD OF 60 DAYS AFTER PLANTING. KEEP ALL PLANTED AREAS GLEAN AND WEED -FREE. 15. WARRANTY ALL PLANT MATERIAL FOR A PERIOD OF 12 MONTHS AFTER PLANTING. REPLACE DEAD OR UNDER -PERFORMING PLANTS IMMEDIATELY UPON DISCOVERY OR NOTICE FROM THE OWNER OR LANDSCAPE ARCHITECT. 16. ENSURE THAT ALL TREES REMAIN PERFECTLY UPRIGHT UNTIL THEIR ROOT SYSTEM 15 SUFFICIENTLY ESTABLISHED TO NO LONGER REQUIRE SUPPORT. ENSURE THAT ALL SHRUBS AND PERENNIALS REMAIN PERFECTLY UPRIGHT UNTIL THEIR ROOT 5Y5TEM 15 SUFFICIENTLY ESTABLISHED TO NO LONGER REQUIRE ADJUSTMENT, IT. LEAVE 51TE IN A GLEAN CONDITION, REMOVING ALL UNUSED MATERIAL, TRASH, AND TOOLS. i w Q FREE -1E (2 REOUIRED) 2'' DIA x 1O' LODGE POLE PINE STAKE ON WINDWARD SIDE OF TREE TREE TRUNK AMENDED SOIL 4" HIGH WATERING BASIN I F'NISH GRADE FINISH GRADE AT SLOPE z_ IN5T.A�; ARBOR GUARD AT THE BASF OF TREE IF IN v' LAWN AREA A) TRrze 5IN6LF. 57AK I N6 MU�GH LA ER 4" H OH WATERING B,AS'N ;-- RECV) FINISH GRADE AT SLOPE I FINISH SURFAGE--i Q O O ROOT BA_L GROWN I" ABOVE FINIS- GRADE AMENDED SOI_ _4" H'GH WATERING BASIN SIN SH GRADE 2x ROOTBALL DIAMETER NOTE: WHERE TREES ARE PLANTED IN TURF AREAS, REMOVE TURF A MIN. OF 12" VIA. AT THE BASE OF THE TREE. INSTALL AN ARBOR C-A)ARD AT THE BASE OF THE TRUNK IF NECE55ARY 'ITREF4 5HRU5 FLANTIN6 PLAN PREVA'L I NG WIND ✓INY+L REE TE j (2 REOUiRED) i TREE TRUNK v J v O � - 2" Di A. x 'O LODGE POLE D O PINE STAKE ON WINDWARD SIDE OF TREE - _ -VINYL TREE TIE REQUIRED) V • - _" DIA. x 10 LODGE POLE P'NE STAKE O"l WINDWARD SIDE OF TREE - -TREE TRUNK AMENDED SOIL_ - 4" HIGH WATERI \G B,AS N „ ■ -FINISH GRADE SECTION �' v B) TREE ® 1;)OUBLF. 5TAK I N6 EDGE GOND TIOP PER PLAF PLANT PER PLAF z x O.G. 5PAGIN5 PLANT LEGEND EDGE OF F-ANTII AREA �2 x O.G. 5PAGING PER PANT LEGEND A' EDGE OF F-ANTING AREA PLAN AMENDED SOIL FINISH GRADE EDGE GOND IT ON PER PLAN SECTION P aiShl GRADE A" NS"ALL ARBOR GUARD AT THE BASE OF TREE r- IN LAWN AREA FULL O.G. 5FACING PER .ANT 5GaEDvLE FULL O.G. CAGING PER NNT 5GHEDULE FULL O.G. 5PAGN6 PER PLANT 5GHEDULE I AN7 PER PLAN -GH LA' ER SE GOLD TION ;' PLAN N-5 �� �ROUN�OO�I R FLANTIN6 (TRIAN6ULATEI;)) - T LLED FLANTING BED, AMEND 50'L PER P.-AN NSTALL 5-REDDED vNOOD MULCH LA -ER (P" DEPTH) OR CRUSHED STONE '-ULr.- (2DEPTH) AS A TOP DRE55 NO PR OR -O PLANTING GROUNDGOVER- SEE GROUNDGOVER PLANTING DETAIL UNDISTURBED NAT VE SOIL F-FINI5H SURFAGE COMPACTED 5UBGRADE i NOTE: SUPPLY MULCH SAMPLE PRIOR TO ORDERING KEEP MULCH BACK FROM TRUNKS A MIN. OF 6" WHERE FUEL MODIFICATION ZONES/HIGH FIRE HAZARD ZONES OCCUR MULCH TO BE CRUSHED STONE. NO WOOD BARK MULCH E ) MULCH LAYER, N T.5. SECTION PLAN OF TREE I 10' 'k- 10' GONGRETE SIDEWALK OR HARDSG.APE IMPROVE\IP_NT AS IND GATED ON PLAN "BID BARRIER OR APPROVED EOU,AL IN574�� IN 20' LENGTHS, TYP. CENTERED ON TREE GOMPAGTED SUBGRADE -GOTIGRETE 51DEWALK OR HAROSGAPE It'•"PROVE'AENT AS IND GATED ON PLAN '1510 BARRIER OR APPROVED EQUAL I"vSTAl IN 20' LENGTHS, TYP, CENTERED ON TREE (E307 i SIDES WHERE HARDSGAPE OCCURS) PLANTS PER PLAN NOTE: ALL TREES WITHIN 10' OF ANY WALK, CURB, DRIVE, BUILDING, UTILITY OR HARD50APE ELEMENT SHALL RECEIVE 20 LINEAR FEET OF ROOT BARRIER CENTERED AT EACH TREE. N.T.5. w IY ku � � O z 4 0. Know whars below. Call before you dig. 4PNOSCAPB �p �1EL0,9 mrT� OF CAL�F��\� REV 151ON5 IST 5USM.TTA:. 04-26-20 4 2ND SUBMITTA- 06-21-2014 3RD SUBMITTA- 04-03-2011 �i () ID IU C � IU 4J t' w IF- z N llJ � 1L dl U! N *3 ul 0 NQ1`1 ttj N d o til > z 4 d�a ed � S i � F-- 4 O X E- d DRAVy'v G?- GIEGKED BY GF DATE 09-03-20 9 5GALE PER PLAN ® 24X36 L-5.I