Loading...
HomeMy WebLinkAbout5860-12a c 4 c 1j TREE STAKING GE POLE TRUNK DER TIE NOT TWIST) PREVAILING WIND DIRECTION "WONDER TREE -TIE" - WRAP WIRE AROUND OUTSIDE OF STAKE. SECURE TO STAKE 'ER MANUFACTURE'S RECOMMENDATION 'LACE BELOW BRANCHING YOKE OF TREE (2) 3" DIA. x 10' LONG LODGEPOLE PINE STAKES: LOCATE OUTSIDE OF ROOTBALL ARBOR GUARD IN TURF .AREAS SET TOP OF ROOTBALL 6" ABOVE FINISH GRADE. INSTALL 4" LAYER OF NnROLIZED WOOD CHIP MULCH. DEEP ROOT BARRIER IF WITHIN 5' OF ANY HARDSCAPE (SEE DETAIL) HATER BASIN / REMOVE ONCE PLANT IS _STABLISHED PER LANDSCAPE ARCH DIRECTION PLANT PIT DRAIN WHEN REQUIRED (PER SEPARATE DETAIL) ^RO POWER FERTILIZER TABLETS. \PPLICATION RATES PER TABLE. REFER f0 PLANTING NOTES. 1ACKFILL MIX PER SPECS. ATIVE SOIL SUBGRADE XCAVATE TO CORRECT HEIGHT OR PLANTING. SCARIFY BOTTOM 0 ENSURE ADEQUATE DRAINAGE OR HEALTHY GROWTH OF PLANT. OHEDULE OF PR EXCAVATION 5GAL -X=6" 15GAL -X=9" 24" BOX & LARGER - X = 12" MAX 1 0 6" 1 MIN. NOTES: MIN. A. POSITION ER AS CLOSE O CURB SIDEWALK AS PI POSSIBLE. RAISED ROOT PROTECTORS ° SHALL BE FACING z o TOWARDS THE TREE. 3 Qo B. TOP OF BARRIER SHALL 4 N 3 BE 1" ABOVE FINISHED — • GRADE. 4 C. LENGTH OF ROOT BARRIER SHALL BE EQUAL TO THE ULTIMATE DRIPLINE OF THE PARTICULAR TREE, OR 3 _ 1 10' MAX. \ LEGEND: �I <;.. 1Q CONCRETE CURB OR . • / L--�--- �- < ... .'I A. a --=_ _•<__. J HARDSCAPE 2 FINISHED GRADE / j 8 APPROVED ROOT CONTROL I BARRIER j ® 3/4" TO 1 1/2" GRAVEL I L OR OCK I 5 DRIP NEHED OF TREE 4 6 1 CENTER OF TREE I i 7 i I PARKWAY WIDTH / TO BE 18" I / LLIINOEARBBARIER RIERIS UB 18-2 I WHEN ADJACENT TO WALK F_ • --- _ .-a --. -.--a----,,� / OR HARDSCAPE OR 24" i " • " LINEAR BARRIER —;— UB 24-2 WHEN ADJACENT \ TO CURB \ AVAILABLE FROM: \ _ 1 CENTURY PRODUCTS 1144 N. GROVE ST. ALIGN W/ ALIGN W/ ANAHEIM, CA 92806 DRIPLINE DRIPLINE (714) 632-7083 OR OR PER MFR. OF TREE PER MFR. SPEC. SPEC. 4) ROOT BARRIER All Underground Service Alert �Q at least 2 days before you dig Know what's below. Call before you dig. TREE OR PALM TRUNK SIDEWALK (WHERE OCCURS) ////'� IPE CAP / �ROOTBALL PI— FIN. GR. r 3" DIA. SCH. 80 PVC STAND PIPE LANTER BACKFILL MIX i ...... °°"°°"° .... COMPACTED SOIL ......o.....°°°°°o°°°° °°°°e% BACKFILL 3" DIA. CORRUGATED A.D.S. PERFORATED RAIN PIPE W/ DRAIN 1 1/2x ROOTBALL SIZE SOCK LAID ® BASE OF ROOTBALL SECTION n TREE OR PALM TRUNK ROOTBALL 3" DIA. SCH. 80 PVC STAND PIPE W/ PIPE CAP � I LIMITS OF PLANT PIT `�_ 3" DIA. CORRUGATED A.D.S. PERFORATED RAIN PIPE W/ DRAIN SOCK LAID 0 BASE OF ROOTBALL PLAN VIEW 2) PIT DRAIN DETAIL O lu III IIIIII J -.III—III III —III J -III-III-III- m :I I L=1I1=1I I -III , � •� .. •; .: x a =1I1=1 o 11=III • • ��' ••� '�'= o0 Off io III .' .C'• v .,.i � I I I I II III -I I I I I -� Ill lll,lll 111 II III III I IIHII 8" MIN. 5) SHRUB PLANTING -HOLD ROOTBALL ABOVE ULTIMATE FINISHED GRADE: 1" FOR 1 GAL 2" FOR 5 & 15 GAL DG LAYER PER SPECIFICATIONS GRO POWER FERTILIZER TABLETS. APPLICATION RATES PER TABLE. REFER TO SPECS. BACKFILL MIX PER NOTES. SEGTION 5 GRAM AGRIFORM TABLETS SEE SPECS. 1" DEEP DG MULCH LAYER e j/ Q° % Q TILLED & AMENDED PLANTING 0 o p o o0 o ib �//� BED PER SOIL TEST NATURAL SUBGRADE F GROUNDCOVER PLANTS JP G9 SEE PLANTING PLANS FOR SPACING I" DEEP DG MULCH \ LAYER. PLAN nT GROUNDCOVER PLANTING UNDERGROUND UTILITIES R SEE NOTE 3 5 "I . — . . — . . . — w' — — z SIDEWALK UTILITY_ 10' 1 5' 1 \ M UNDERGROUND STRUCTURE CATCH BASIN TRANSFORMER VAULT. ...... — R — SIDEWALK DRIVE I w APPROACHI S.L. 10 z i i CURB AND GUTTER a 5' t MIN f'� 5' 10' I 10' MIN MIN - j MIN HOLD ROOTBALL ABOVE ULTIMATE 5 FINISHED GRADE: MIN 1" FOR 1 GAL NOTES: 2" FOR 5 & 15 GAL DG LAYER PER SPECIFICATIONS 1. TREE SPACING SHALL CONFORM TO PLANS APPROVED BY THE CITY ENGINEER AND FUEL MODIFICATION PLAN, TEMPORARY 2" HIGH WATER 2. ALL TREES IN THE R.O.W. ARE SUBJECT TO LINE.OF.SIGHT BASIN. REMOVE ONCE PLANT IS ESTABLISHED CRITERIA AS APPROVED BY TRAFFIC ENGINEER. GRO POWER FERTILIZER TABLETS. 3. AT ALL LOCAL RESIDENTIAL INTERSECTIONS THE FIRST TWO PARKWAY APPLICATION RATES PER TABLE. TREES AT ALL APPROACHES TO BE PLACED BEHIND SIDEWALK. REFER TO SPECS. 3ACKFILL MIX PER NOTES. 4. MAINTAIN 10 FEET FROM CENTER OF STREET TO EDGE OF ALL UNDERGROUND FACILITIES. 5. MAINTAIN 10 FEET FROM ALL STREET LIGHTS, UTILITIES STRUCTURES AND VALVE BOXES. J I - - i U ❑, QI CURB AND GUTTER METER TYP. TYP. 6) TREE PLACEMENT PLANTING NOTES TREES LEGEND TREES BOTANICAL NAME Geijera parviflora Lagerstroemia hyb. 'Muskogee' COMMON NAME Australian Willow Crape Myrtle SIZE COMMENTS WUCOLS QTY 24" Box STD M 55 24" Box STD M 70 Platanus x acerifolia 'Bloodgood' London Plane Tree 24" Box STD M Pyrus calleryana 'Chanticleer' Chanticleer Flowering Pear 24" Box STD M SHRUBS, GROUNDCOVE AND VINES LEGEND NONE SHRUBS BOTANICAL NAME COMMON NAME SIZE SPACING WUCOLS QTY Agave desmettiana Dwarf Century Plant 5G L 252 0 Agave weberi Weber's Agave 15G L 42 0 Agave x 'Blue Flame' Blue Flame Agave 5G L 153 0 Agave x 'Blue Glow' Blue Glow Agave 5G L 43 Chondropetalum tectorum Cape Rush 5G M 92 Heteromeles arbutifolia Toyon 5G L is G Lantana sellowiana 'Pink' Pink Trailing Lantana I G L 502 Moraea bicolor Fortnight Lily 5G M 487 ® Phormium tenax ' Sundowner' New Zealand Flax 5G M 156 Rhaphiolepis indica 'Ballerina' Ballerina Indian Hawthorn 5G M 543 O Rosa x 'Flower Carpet Var Noraturn Red Flower Rose IG L 110 Salvia greggii 'Purple' Autumn Sage IG L 174 Tecoma stans Sierra Apricot 5G M 95 O Westringiaf'Compacta: Coast Rosemary 5G L 148 SHRUB AREAS BOTANICAL NAME COMMON NAME SIZE SPACING WUCOLS QTY vv ovovo Carex tumulicola Foothill Sedge 1 G @ 30" D.C. L 940 E o° 10 Leymus condensatus 'Canyon Prince' Canyon Prince Wild Rye 5G @ 36" D.C. L 339 TOP DRESSING (FUEL MODIFICATION AREA) ALL SHRUB AND GROUNDCOVER AREAS SHALL BE TOP DRESSED WITH A 3" LAYER OF s" - Y2" CRUSHED ROCK "CALIFORNIA GOLD" OVER SMOOTH FINISH GRADE AS MULCH/BARK SUBSTITUTE AFTER ALL PLANTING. SUBMIT SAMPLE TO LANDSCAPE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. WEED CONTROL WHERE PERENNIAL WEEDS EXIST ON SITE AT THE BEGINNING OF WORK, CLEAN AND REMOVE THESE EXISTING WEEDS BY MOWING OR GRUBBING OFF ALL PLANT ON AND PLANTING OF ALL SPECIM MATERIAL. UPON ABATEMENT PROGRAM BY APPLYCOMPLETION OF SOIL ING: 100 POUNDS OF A COMMERCIAL FERTILER, BEGIN WEED IZ ACRE AND PER MANUFACTURER'S SPECIFICATIONS. WATER ALL AREAS FOUR IZ TIMES DAILY FOR FOURTEEN (14) CONSECUTIVE DAYS UNTIL WEED SEEDS HAVE GERMINATED. CEASE WATERING FOR THREE (3) DAYS. SPRAY ANON -SELECTIVE, NON -RESIDUAL, SYSTEMIC HERBICIDE TO ERADICATE GERMINATED WEEDS. LET THE WEEDS DIE WITHOUT IRRIGATION FOR A MINIMUM DEPTH OF 1/4"INCH BELOW THE SURFACE OF THE SOIL. IF STUBBORN AND RESIDUAL WEEDS (I.E. BERMUDA) SHOULD PERSIST ERADICATION PROCEDURE SHOULD BE REPEATED, THE OF WEEDS BE IDENTIFIED ITAN "PROVED LICENSED PEST CONTROL ADVISOR TO ENSURE COMPATIBILITY COORDINATED H CHEMICAL AND SEASON OF APPLICATION. DO NOT USE MATERIAL OR METHOD THAT WOULD ADVERSELY EFFECT NEW PLANTINGS, SLOPE STABILIZATION OR HYDROSEEDING. SOIL TEST AFTER ALL SOIL HAS BEEN IMPORTED TO THE SITE AND ROUGH GRADING COMPLETED BUT PRIOR TO SOIL PREPARATION, SEVERAL SOIL SAMPLES SHALL BE TAKEN BY THE SOILS LABORATORY OR BY THE CONTRACTOR AT THEIR INSTRUCTION AND A REPORT/RECOMENDATION PRODUCED. THE CONTRACTOR SHALL FURNISH A COPY OF THE SOIL TEST FOR AGRICULTURAL SUITABILITY AND FERTILITY (PREPARED BY A CALIFORNIA ASSOCIATION OF AGRICULTURAL LABORATORIES MEMBER) TO THE CONTRACTING OFFICER AND THE CITIES INSPECTOR, UPON REVIEWING THE SOILS REPORT THE ARCHITECT MAY MAKE SPECIES SUBSTITUTIONS TO THE PLANT LIST. 59 i 1 T E S C A IP E 5 9 Landscape Architecture and Planning 3190 B2 Airport Loop Drive Costa Mesa, CA 92626 Richard Polhannus, License CA—#2782 (949) 644-9370 (714) 210-3140 FAX SOIL PREPARATION MACHINE ROTOTILL THE FOLLOWING AMENDMENTS INTO THE SOIL AT RATES INDICATED PER 1000 SF: (THESE RATES ARE FOR BID PURPOSES ONLY, ACTUAL RATES TO CORRESPOND TO CONTRACTOR'S SOILS REPORT). 4 CU. YDS NITROGEN STABILIZED SAWDUST 150 LBS GYPSUM 125 LBS STANDARD FERTILIZER DEEP ROOT BARRIERS ALL TREES WITHIN 7 FEET OF ANY PERMANENT HARDSCAPE ELEMENT SUCH AS CONCRETE WALKS, WALLS OR BUILDINGS SHALL BE PLANTED WITH AN APPROPRIATE SIZED ROOT BARRIER (UNLESS OTHERWISE NOTED ON PLANS). ROOT BARRIER TO BE LINEAR PANEL (TYP.) SEE DETAIL. SPECIAL NOTE CONTRACTOR SHALL SUPPLY ATOP LAYER OF 3" CLEAN "3/4"-MINUS" TOPSOIL TO ACHIEVE FINAL FINISH GRADE PRIOR TO "TOP DRESSING" D.G.. ANY ROCK OR BOULDERS OVER 1" DIA. SHALL BE BURIED A MINIMUM OF 12" DEEP OR REMOVED FROM THE SITE. THE CLEAN TOPSOIL CAN EITHER BE GENERATED "ON -SITE" OR IMPORTED. THIS TOPSOIL SHOULD BE APPLIED AFTER IRRIGATION AND DRAINAGE WORK HAS BEEN COMPLETED, QUALITY OF TOPSOIL SHALL BE APPROVED BY THE CITY PRIOR TO INSTALLATION AND SHALL MEET ALL CITY STANDARDS. CITY OF FONTANA SCALE LANDSS APE P�L7ANS 190_20, DI BY, SIERRA AVE1V IJJ SCALE, DESIGNED BY, STA. 73+00.39 TO STA. 99+91.12 AS SHOWN PLANTING DETAIL, NOTES, AND LEGENDS DATE' CHECKED BY, APPROVED BY, � DRTE� D ND., 1 XxX Set.b 17 � N � �00 N IOC�I Q Cd I-L1 O Cd d 00 O O Cs U W O � �ANDS�4p S~�Rc pRp A. Pot y4,,p 1� 2/78822�`°s �. OF PC # LSPC 19-000009 DATE 12/18/18 J08 # 18-023 Ll 1 12 OF 17