Loading...
HomeMy WebLinkAbout5860-6V N N 0 I v IRRIGATION NOTES IRRIGATION LEGEND SLOPE OF STREET Irrigation System Maintenance Procedures x x Har LN While the system is designed to operate automatically, a regular maintenance schedule DIAGRAMMATIC PLAN SYMBOL MFG. MODEL NO. DESCRIPTION RAD. GPM PSI PRECIP. FLUSH VALVE (TYP.) (SEE DETAIL x x THIS SYSTEM IS DIAGRAMMATIC. ALL PIPE, VALVES, ETC. SHOWN RATE (SEE DETAIL) AIR RELIEF VALVE (TYP.) TYPICAL DRIPLINE LAYOUT AS PER DETAIL is necessary to prevent and address failures in the system as well as ensure that the - - - - - -� - - - - - - - - - - - - - - - - - system operates in a manner that meets or exceeds the MAWA values provided. WITHIN PAVED AREAS ARE FOR DESIGN CLARIFICATION ONLY a RAINBIRD (2) RWS-B-C-1401-GRATE-P ROOT WATERING SYSTEM .5 30 .70"1 - - - - - - --i AND SHALL BE INSTALLED IN PLANTING AREAS AND JOINT OR (2) 1401 BUBBLER ON 1/2" OR TREE BUBBLER ON RISER TRENCHES WHEREVER POSSIBLE. SCH. 80 RISER WITH HUNTER An broken or malfunctioningirrigation system components should be replaced with SPRINKLER ADJUSTMENT REQUIRED y g y p � 1/2" HC-50E-50F CHECK VALVE the same components, or an equal or superior equivalent. q P q WHEN PIPES ARE ON -GRADE �'-� ' • -_� - _.� �.1-- _ - _ _ _ _ _ _ _ _ = p THE IRRIGATION CONTRACTOR SHALL FLUSH AND ADJUST ALL - •" • __ • - "- - - - SPRINKLER HEADS FOR OPTIMUM PERFORMANCE AND RAINBIRD XFS-P-06-18-100 DRIP LINE SYSTEM .5 30 .43'1 Upon completion of the project, the following measures should be performed by PREVENT OVERSPRAY ONTO WALKS AND ROADWAYS AS MUCH Per 100s.f. property management at intervals noted below: AS POSSIBLE. THIS SHALL INCLUDE SELECTING THE BEST -� RAINBIRD XFS-P-06-18-100 DRIP LINE SYSTEM 5 30 .43"/HR 24" TYP. 24" TYP. DEGREE OF ARC TO FIT THE EXISTING SITE CONDITIONS. CONTRACTOR TO USE PRESSURE COMPENSATING SCREENS Per 100s.f. OF TREE Weekly WHEN RADIUS IS REDUCED MORE THAN FIFTY PERCENT (50%). RAINBIRD XFS-P-06-18-100 DRIP LINE SYSTEM .5 30 .43"1 n During weekly landscape maintenance operations, the maintenance personnel should Per 100s.f. SEE CHART BELOW SEE CHART BELOW look for signs of runoff, erosion, and plant die off due to irrigation system failures. If FIELD CONDITIONS RAINBIRD XFS-P-06-18-100 DRIP LINE SYSTEM 5 30 .43"/HR FOR MAX. LENGTH OF DRIP LINE FOR MAX. LENGTH OF DRIP LINE DO NOT WILLFULLY INSTALL THE SPRINKLER SYSTEM AS Per 100s.f. issues are detected, they should be brought to the attention of the maintenance INDICATED ON THE DRAWINGS WHEN IS OBVIOUS IN THE DRIP IRRIGATION NOTES NOTES: supervisor and property management for timely correction. FIELD THAT UNKNOWN OBSTRUCTIONS OR GRADE FOR VALVES ON SLOPES, THE CONTRACTOR SHALL INSTALL RAINBIRD XFSCV-06-18 FOR SHRUB OR a SLEEVE LI ALL ROAD CROSSINGS (TYP) LOCATE SERVICE LATERAL IN EACH DRIP Inlet PraF M I LaM ILmgM Wean 5 (1) MAINLINE SLEEVE N2 6 Ilnowidwr N 6nalFlowIDPM11: NA SI IFI w10pN DIFFERENCES EXIST AND SHOULD BE BROUGHT TO THE XFSCV-06-12 FOR TURF APPLICATION FOR THE ENTIRE VALVE. (1) WIRE SLEEVE AREA AT CENTER. LOCATE (1) FLUSH 0.¢2 D6 OR DA O6 Da ns D.D Monthly: VALVE AT EACH END OF PLANTED AREA AS �;' 'E1 2'S '� "0. "" ,aso 124 `' aP2 Y: ATTENTION OF THE CONTRACTING OFFICER. IN THE EVENT SEE NOTES FOR EXCEPTIONS 0 "9 33 "'' ' 41 413' RK, 508 �" All irrigation and master valves shall be visually inspected by a property management THAT THIS NOTIFICATION IS NOT PERFORMED, THE THE CONTRACTOR WILL NEED TO FIELD LOCATE THE AIR RELIEF VALVES AT THE HIGHEST LOCATIONS PER DETAIL-(2) FLUSH VALVES PER AREA. 0 Ma 3� its ;'30 4as Z siz 47 'n - MARK SLEEVE CROSSING ON FACE OF CURB LOCATE AIR RELIEF VALVE AS REQUIRED '05 41J & clo 526 420 0 66 l representative while the valve is under operating conditions. All control valves and CONTRACTOR MUST ASSUME FULL RESPONSIBILITY FOR ANY ON EACH DRIP LINE SYSTEM. Ica - ns 460 290 734 ss6 45s . zoo sin REVISIONS REQUIRED. WITH AN "IR" STENCIL. BY DETAILS - - -S filters should be visually inspected and cleaned as required and in accordance with 3 ANY AREA WITH DRIP IRRIGATION SYSTEM REQUIRES LONGER FLUSH VALVES ARE TO BE INSTALLED AT THE END POINT OF ALL DRIP LINE SYSTEMS AND AT THE EXTREME END DRIPLINE THAN MAXIMUM LENGTH, THE DRIP IRRIGATION manufactures specifications. All leaks shall be promptly reported to a landscape SWING JOINTS OF EVERY DRIP SYSTEM. THE CONTRACTOR SHALL INSTALL (2) RAINBIRD OPERIND (MPN: #X17500) OPERATION SHALL BE INSTALLED AS MULTIPLE DRIP AREAS. maintenance representative so that the valve may be repaired or replaced in a timely INSTALL ALL HEADS WITH DOUBLE OR TRIPLE SWING JOINTS, INDICATORS PER DRIP VALVE. ONE AFTER THE DRIP VALVE AND ONE AT THE END OF THE MANIFOLD SYSTEM. fashion with the minimum amount of leaking water exposed to open air. USING STREET ELLS, AS PER DETAIL. J I TYPICAL PARKWAY DRIP SYSTEM LAYOUT CONTRACTOR TO EVALUATE THE PRECIPITATION RATES OF DRIP LINE AGAINST SOIL TYPE/ INFILTRATION RATE MINIMUM PRESSURE AND MAXIMUM GALLONS ON REQUIRED SOIL REPORT. ANY NECESSARY EQUIPMENT CHANGES SHALL BE BROUGHT TO THE ATTENTION OF All Root Watering Systems are to be visually inspected to insure that all locking grates REQUIRED are bein reasonabl ke t free of debris. All ates that are not ke t reasonabl free of THE LANDSCAPE ARCHITECT FOR FURTHER DIRECTION RAINBIRD DRIP LINE MODEL -SEE LEGEND 4 C Odebris are to be reported to a landscape maintenance representative. All Root Watering OPERATINADESIGNER SYSTEM MINIMUM A1z L PRESSURE AND A MAXIMUM DEMAND Fv RAINBIRD FLUSH VALVE ASSEMBLY - SEE DETAIL Systems that have their locking grates damaged or missing are to be reported to a POINT OF CONNECTION, AS NOTED ON THE PLAN. BEFORE 1 3 13 5 Y g g g P 2 TOP 2/3 landscape maintenance representative so that the locking grate may be repaired or INSTALLING THE SYSTEM, CHECK POINT OF CONNECTION AND (AIlll RAINBIRD AIR RELIEF VALVE -SEE DETAIL CONTROL ZKN NE L DRIP NE �' 8 AR OF SLOPE replaced in a timely fashion. IMMEDIATELY NOTIFY CONTRACTING OFFICER IF PRESSURE IS H NIBCO BRASS BALL VALVE (LINE SIZE) T-585-70 (3/4"-2") / T-580-70-66 (2-3/4"-3") oNNEcn NOT AVAILABLNOT AS NOTED E. THE REQUIRED GALLONS PER MINUTE IS 4" AND LARGER TO BE FEBCO NRS SERIES GATE VALVE - LINE SIZE. MAINTENANCE LOG Keep a log of all inspections and maintenance performance on the irrigation system WATER LINE UNDER PAVING RAINBIRD EFB-CP-R-PRS-D SERIES REMOTE CONTROL VALVE W/ PRESSURE REGULATOR- SIZES INDICATED ON PLANS 1 FOR PA DEEP. ALL LATERAL LINES UNDER PAVING SHALL BE SCH 40 r _ (Updated copy to be provided to Property Manager on a monthly basis) ALL MAINLINE UNDERPAYING SHALL INSTALLED SET PRESSURE REGULATOR MODULE TOTAL PSI OF OPERATING PRESSURE + PSI LOSS AT LATERAL PIPE. SCH @ 3 PVC AND INSTALLED 24" DEEP. ALL LINES TO BE INSTALLED RAIN BIRD 33 DNP LOCKING W1 PURPLE RUBBER CAP, QUICK COUPLER. 12" FOR TURF 4 Overall Landscape Maintenance Procedures O I� IN SLEEVE 2X DIA. OF LATERAL LINE. -�) s BOTTOM / SYSTEM COVERAGERAINBIRD 100-EFB-CP OF SLOPES At a minimum, the following items should be addressed on a regular basis as required THE IRRIGATION CONTRACTOR IS TO ADJUST HEAD ® & RAINBIRD PRB-QKCHBRASS 0 1" PRESS REN REGULATING QUICK CHECK BASKET / FILTER AND BALL VALVE lsJ per city code & fuel modification requirements: LOCATIONS IN THE FIELD IN ORDER TO GUARANTEE 100% 200 MESH STAINLESS STEEL SCREEN. INSTALL PURPLE HANDLE COVER. 3 COVERAGE. CONTRACTOR TO CONTACT THE CONTRACTING ® WATER METERS -REFER TO CIVIL PLAN Monthly OFFICER PRIOR TO ANY MAJOR CHANGES) RESULTING IN Dead, dying and diseased vegetation should be replaced with equivalent plant material ADDITIONAL COST TO THE OWNER. 2" WILKINS 375 XL SERIES REDUCED PRESSURE BACKFLOW PREVENTER W/ 2" WYE t FV w/ similar hydrozone requirements, provided that the replaced vegetation does not SUPPLEMENTAL TREE IRRIGATION STRAINER - SEE DETAILS. result in mixing higher water use plants with low water use plants in the same TREES WHICH HAVE NOT BEEN SUPPLIED WITH A ROOT O AUTOMATIC CONTROLLER LOCATION -SEE NOTE ON PLANS �0°g°�0110 of eor 10 hydrozone. ZONE WATERING SYSTEM IN DRIP IRRIGATED AREAS ARE LV TO RECEIVE (4) PC-05 W/ PC DIFFUSER CAPS SPACED 'DATA INDUSTRIAL'- 228PV2005 2" FLOW SENSOR Invasive plant species should be eradicated as required. EQUALLY IN 24" DIA. AROUND TRUNK OF EACH TREE AND TIED INTO THE DRIP SYSTEM EZFLO-EZ003-CX FERTILIZER INJECTOR Plant material should be maintained in order to avoid obstruction of motorists views. DRIPLINE INSTALLATION AT TREES INSTALL PER MFG. SPEC. IN CARSON L-SERIES VAULT DOWNSTREAM FROM FLOW SENSOR CONTRACTOR TO INSTALL DRIPLINE AT TREES TO PROVIDE 2" RAINBIRD EFB-CP SERIES MASTER VALVE W/ PURPLE HANDLE COVER NTROL ZONE KIT -SEE DETAIL 2 Annually 48" SQ. CLEARANCE AROUND TREE TRUNK WHICH ARE RELIEF C SCH 40 40-45 DEGREE Decorative rock should be r lenished in order to maintain a ro riate soil moisture INSTALLED IN DRIP IRRIGATED AREAS. MAINTAIN DRIP (PURPLE PVC SCH 40 LATERAL LINE- 12"COVER IN PLANTING AREAS, 24" COVER UNDER ASSEMBLY BOW pp p SYSTEM CONNECTIONS WITH APPROPRIATE DRIPLINE ELLIS PAVING. )- SIZES INDICATED ON PLANS levels.0 LATERAL LINE -SIZE PER LEGEND AND TEE'S 4 (a) RAINBIRD AIR RELIEF VALVE KIT, h, WHEN SLOPE IS GREATER THAN 4:1, INSTALL (BROWN) UVR PVC SCH40 LATERAL LINE ON GRADE z 3 4 B 10 PLACED AT HIGHEST SPOTS IN THE WELD Soil amendments consistent with the agronomic soils report for this project should be HEAD INSTALLATION ADJACENT TO HARDSCAPE STAKED @ 10' O.C. - SEE PIPE ON GRADE DETAIL. applied in the manner prescribed in order to support and maintain healthy plant growth. (FONTANA) INSTALL KING BROS. KSC-T SERIES LINE SIZED INLINE SWING CHECK VALVES @ W INCREMENTS OF VERTICAL RISE. X X X X X X X X X y y y y ALL ABOVE GROUND IRRIGATION HEADS ADJACENT TO 12" 1 11 � PVC SCH ao SLIP TEE IRRIGATION PIPE NOTE: 6" © PVC SCH 40 TEE (USE ELBOW 0 LAST Fuel Modification STREETS OR STREET ADJACENT IMPERVIOUS SURFACES ARE SYSTEM ON THAT SIDE OF THE VALVE) TO BE INSTALLED 2411 AWAY FROM THE EDGE OF THE + IDENTIFY ALL ABOVE GROUND IRRIGATION WATER LINES BY CONTINUOUS LETTERING ON THREE INCH Q REDUCER BUSHING Fuel Modification inspections should be performed as prescribed to ensure that plant 8" 1'-2" 3/4" X 1/2" SURFACE. SEE SPRAY HEAD DETAILS FOR ADDITIONAL (3" MINIMUM WIDTH PURPLE TAPE WITH ONE INCH BLACK LETTERING BEARING THE CONTINUOUS © PVC ADAPTER TO materials & trees remain compliant w/ the requirements of the approved "Fire INFORMATION. WORDING "CAUTION: RECYCLED WATER - DO NOT DRINK" PERMANENTLY AFFIXED AT FIVE FOOT 0M + DRIP 600-CF-1 Protection Master Plan for the Summit at Rosena" prepared by Dudek (May, 2018) IRRIGATION AUDIT INTERVALS ATOP ALL HORIZONTAL LATERAL LINE. 18" o�°°0 0082.06060 O°o 0 0 o0 s FL DRIP LINE SEE LEGEND +LATERAL LINE THAT IS WITHIN 5' OF PAVEMENT OR D.G. PAVING EDGE SHALL BE BURIED. °gOg�'�°Og ° �° °"°" �0�°�° FLUSH VALVE ASSEMBLY. SEE DETAIL `I TOP 2/3 OF SLOPE j 0 � BOTTOM 1/3 OF OFFFFONTANA REQUIREMENTS. BE PERFORMED PER CITY + LATERAL LINE THAT IS CROSSING ANY HARDSCAPE PAVING ON SLOPE SHALL BE BURIED IN SLEEVE. t1 FINISH GRADE OR MULCH '1 NORMAL SPACING SLOPE SPACING pq pp, p�p� t© PC DRIPLINE CONNECTIONS. SEE DETAIL x = DISTANCE BETWEEN ROWS OF DRIP LATERALS AS STEP 1 2 1 (PURPLE) MAINLINE - SEE DETAIL FOR INSTALLATION DEPTHS. - SIZES INDICATED ON PLANS OXOXOOOXO_fiOFQO °O O Y X� 7® PVC LATERAL TO CONNECT TO NEXT DETERMINED BY PLANT AND SOIL TYPE. SEE NOTE 1. M81r1IIneS r O OQ O o 0 0 0 0 0 SYSTEM. SIZE PER LEGEND y = INCREASED DISTANCE BETWEEN ROWS OF DRIP LATERALS (pressurized) 11/2 Inch and smaller shall be Schedule 40 solvent -Weld P.V.C. AS DETERMINED BY PLANT AND SOIL TYPE. SEE NOTE 1. { Mainlines (pressurized) 2 inch through 3 inch shall be Class 315 solvent -weld P.V.C. 7�� IN CONTRACTOR TO USE INSTALL THRUST BLOCKS TO 2" MAINLINE, 2 DRIP LINE FOR SUBSURFACE 11V INSTALLATION /\\�\\// \/�\\/�\\%/�� 4 - - PVC SCH 40 WIRE SLEEVE. STEP 2 3 1 = PVC SCH 40 MAIN AND LATERAL LINE SLEEVE 2x DIA. OF PIPE ENCASED. - PROVIDE THAN 2" PVC SCH 40 TEE OR ELL SLEEVES UNDER HARDSCAPE (CONCRETE / ASPHALT IN EXCESS OF 4' WIDE). IF PUTTING LANDSCAPE DRIPLINE UNDER SOIL, DO NOT BURY MORE 18" FOR PA 18" FOR PA IF rr 1 FINISH GRADE TURF THAN 2" BELOW GRADE AND INCLUDE AIR RELIEF VALVE (SEE DRAWING- 12" FOR TURF 12" FOR TURF PVC LATERAL PIPE - SEE LEGEND 1 - Z O / NOTE "AIR RELIEF VALVE KIT"). BARB DRIP TEE: w ALL CONTROL WIRE, LATERAL AND MAINLINE PIPE RUNS TO BE INSTALLED IN SEPERATE SLEEVES. RAIN BIRD XFF-TEE OOPRAINTIBIRDNMODEL: OPERIND BARD DRIP TEE: . ALL SLEEVING TO BE SCH. 40 PVC. RAIN BIRD BT50 2 _ O LANDSCAPE DRIPLINE TUBING: srEP 3 6 5 ` SIZING : LANDSCAPE DRIPLINE TUBING: BARB RAPT MALE ADAPTER - WIRE SLEEVES, MUST BE OVERSIZED LEAVING AMPLE ROOM FOR FUTURE WIRE ADDITIONS OR RAIN BIRD LANDSCAPE DRIPLINE RAIN BIRD XFF-MA-075 3/4" MPT MALE ADAPTER SEE LEGEND FOR SPECS.)REPAIRS. (SEE LEGEND FOR SPEC.) OR RAIN BIRDXFF-MA-050 1/2" MPT MALE ADAPTER ( BARB DRIP ELBOW: - PIPE SLEEVING TO BE 2 x DIAMETER OF PIPE ENCASED. FINISH GRADE RAIN BIRD XFF-ELBOW LANDSCAPE DRIPLINE TUBING: RAIN BIRD LANDSCAPE DRIPLINE TIE DOWN STAKE: LANDSCAPE DRIPLINE TUBING: (SEE LEGEND FOR SPEC.) 3 / - INDICATES WATER REQUIREMENT RAIN BIRD TDS-050 W/ BEND RAIN BIRD LANDSCAPE DRIPLINE 1--2- / Q// /j�/j\/�/�// /�//�/� INSTALL ® 3' O.C. (SEE LEGEND FOR SPEC.) a� STEP 4 7 x INDICATES STATION NUMBER 00 8 x x INDICATES CONTROLLER x x INDICATES GPM \ \ � INDICATES VALVE SIZE �'-- X INDICATES HYDROZONE AREA (SQUARE FOOTAGE) LANDSCAPE DRIPLINE TUBING 1. SLIP BASE SOCKET OVER ENDS OF WIRES. i >/i?/i?✓iyi�Yili?>/i: /T/i) RAIN BIRD LANDSCAPE DRIPLINE 2. STRIP WIRES APPROX. 3/8" FROM ENDS - (SEE LEGEND FOR SPEC.) TWIST TOGETHER. EASY FIT COMPRESSION COUPLING: EASY FIT COMPRESSION COUPLNG: 3. PUT CRIMP SLEEVE OVER WIRE ENDS - RAIN BIRD MDCFCOUP RAIN BIRD MDCFCOUP CRIMP AND CUT OFF EXCESS WIRE. EASY FIT COMPRESSION FLUSH CAP: NOTE: 4. APPLY SEALER TO OUTSIDE OF SEALING 1. INSERT BARB TRANSFER FITTING DIRECTLY INTO DRIPLINE TUBING. EASY FIT COMPRESSION FLUSH CAP: RAIN BIRD MDCFPCAP 2. VAN NOZZLE MAY BE SET TO CLOSED, OR IF IT IS DESIRED TO SEE SPRAY PLUG -FILL CAVITY WITH SEALER. THE NOZZLE, SET THE ARC TO Y4 PATTERN. THE FLOW FROM THE 5. PULL BASE SOCKET OVER CRIMPED CON - FROM BARB DRIP COUPLING: RAIN BIRD MDCFCAP NECTION AS FAR AS POSSIBLE. RAIN BIRD XFF-COUP OR BARB MPT MALE ADAPTER NOZZLE, 0.3 GPM, SHOULD BE ACCOUNTED FOR IN THE SYSTEM DESIGN. COMPLIANCE STATEMENT EASY FIT PURPLE COMPRESSION FLUSH CAP: RAIN BIRD XFF-MA-075 3 4 MPT MALE ADAPTER 6. PUSH SEALING PLUG INTO BASE SOCKET. HAVE COMPLIED WITH THE CRITERIA OF THE ORDINANCE AND BARB MPT MALE ADAPTER / " 3. INSTALL (2) RAIN BIRD OPERIND (MPN #X17500) OPERATION INDICATORS RAIN BIRD XFF-MA-075 3 4" MPT MALE ADAPTER RAIN BIRD MDCFPCAP O OR RAIN BIRDXFF-MA-050 1/2" MPT MALE ADAPTER 7. PUSH WIRES TO END OF BASE SOCKET OR RAIN BIRD XFF-MA-050 1/2" MPT MALE ADAPTER PER DRIP VALVE. ONE AFTER THE VALVE AND ONE AT THE END OF THE INSTALLATION NOTE: MANIFOLD SYSTEM. TO ASSURE COMPLETE SEALING OF APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IRRIGATION DESIGN PLAN IG 1. CONTRACTOR TO CONNECT LANDSCAPE DRIP LINE WITH XF DRIPLINE INSERT FITTINGS/CONNECTORS 8RAIN BIRD SNAP -TITS" WIRE CONNECTOR CONNECTION. IN THE �•`'7�'�`^' GATION 2. CONTRACTOR TO INSTALL RAIN BIRD MDCFCOUP EASY FIT COMPRESSION COUPLING ATT. FLUSH VALVE OR APPROVED EQUAL �7C/q 3/19/19 3 PC DRIP LINE CONNECTIONS 4 DRIP OPERATION INDICATOR (5) WIRE CONNECTOR RICK POLNAMUS LAJ2782 EXP. 10119 DATE City Of Fontana Irrigation Controller Standard �rM NOTE: For Cortirnunities Facilities Districts �l ALL POWER WIRES, GROUND WIRES ETC. SHALL BE SEPARATELY SLEEVED AND SWEPT THROUGH (CFD) 4� ENCLOSED PAD WITH SCH 40 RIGID CONDUIT H C EXACT LOCATION OF CONTROLI FIR SHALL BE AGREED ALL SLEEVING SHALL BE A MINIMUM OF 18` BELOW �) UPON BY EDISON, CRY I-ANDSCAPE INSPECTOR AND FINISHED GRADE. ALL SLEEVING IS A GRAPHIC REPRESENTATION CONTRACTOR PRIOR TO ANY TRENCHING OR OF A TYP INSTALLATION WIRE PLACEMENT IRRIG. CONT. (4az:, xfi $ 9 (( r v 1'�f Toro Sentinel controller installed in an approved stainless steel Edison meter box enclosure. �J �'.�y '^ "Sr° �� SIZE OF CONC. BLAB = 8' THICK I - FINISHED B GRADE r Fr i w/J4 CEDARS AT 1T O.G. VP pp s .. .. t a 3 �� Contact Green Product Sales with the following numbers for the City of Fontana 2-VALVEBOX&COVER 20'LX ifiWX12A , c�,3T '°*f, ; .� a U 3 - PROPORTIONING CAP WITH FEED � GENERAL NOTES: meter/controller. C ADJUSTMENT KNOB � pJ 10 i II Il (� � PRONDE HOOP METER AND 5OA/ZP AWN C/B WHERE INDICATED i \J ❑p ON DRAWINGb 8" DIN. X 12' D. 0 dable CA D ADE tl ,otlucfs ec ficatio 4-EZ FLOS 'e P M HUT OFF VALVES WITH P PROVIDE PAN0.BOAR w BOTTOML s H D HERE INDICATED ON WERE INDICATED E 8 GROUND WELL .-ill at wx zfl f rtillzln .c oml3-0sa 9 P WITH PARKWAY DISCON'V}; T 3" COVER C WASHERSFontana art f PROVIDE IRRlranoN coNraou.ER CABINET WHERE INmcaTED Flu WITH PEA GRAND- 5 p #. or a 48 Station controller mr � v ON DRAWINGS. -EZ FLO MODEL EZ003-CX FERTILIZING SYST'I:M I".,r O()-t�,ta Features ON a..a a„ ESB48-U2-MPEAI610K-0Bl-VRA TERMINATE AT LOCATION HNiDHOIF. PER S.C.E. COMPANY EEO. 3 VEARYPRIOR E TRENCHING LOCPGON AND ERWN n¢N CEO. WITH S.C.E. CO. ` 4 CEDARS ZF L X $° U X I I e A PRIOR TO TRENCHING 4^ J TYP. 5/8-DIA % 10' DRIVEN GROUND 2 4 4 Tank Capacity- Liquid: Approx. 2 5 Gal. (( S liters) CONDUR AND CONDUCTOR SIZES ARE BASED ON NnNMEFALLEO CONDUIT ROD PER ARTICLE 250-81 6-FERTILIT.ER OUT -CONNECT CLEAR Tank Capacity -Water Soluble Fertilizer: Up to 15 - 18 lbs. (6.8 - 82 kg) Model #MPS-A16-10K aND COPPER CONDUCTORS WH TYPE 'DIHN/rNwN• iNsuunoN. ' 1 14 TUBE TO GREEN CONNECTIONS ON Minimum Flow Requirements: 2.5 gallons/hour (9.51iters/hr.) ,z; of Tsso NEC Required items to be included with each controller installed: 5 PROPORTIONING CAP AND COUPLING Adjustable Feed Ratio Range: 15,000:1/Slow setting to 400:1/Fast setting Water Volume to Empty Tank: 37,500 gal (142 kp/Slow setting I . WI 2-XB Toro Sentinel 12 station wireless output board, level 3 surge protection with 7-WATER IN- CONNECT BLACK 1,000 gal (3.8 kl)/Fast setting XB-Spread Spectrum Radio TUBE TO BLUE CONNECTIONS ON Unit Dimensions (LWH): 2 1 " x 8" x 11" (53cm x 20crn x 28cm) IRRIGATION CONTROL PROPORTIONING CAP AND COUPLING Valve Box Minimum (LWH): 24" x 13 x 16" {61 cm x 33cm x 41 em) BOARD r PROVIDE 20 AMP 2. TK-3170 Kenwood hand held remote w/ chargerset o Cityof Fontana frequency w .. Approx. Weight: 11 lbs. I kg) I I' METER FACES 2 ROLE BREAKER M J STREET FOR NEW PUMPS $-1Jq TUBING CLAMP BOTH TIICONNEN METER 1 WHERE APPLICABLE programming PUMP 6 AND BLUE COUPLING TUBING CONNECTIONS I STRONG Box w A TER IATE RA MOUNTING 7 Suggested Landscape Coverage under normal watering conditions': I I MODEL NO. SB- 24SS/120V 2P rowEw 144L sue 3. After controller installation contact Green Product Sales to schedule inspection for U to 15,000 s ft 1,395 s m 120/240 9 - APPROVED BACKFILL 100.% turf I r p q ( o ) certification '^ 75%P turf/25%treeslshrubs/flowers Up to 22,500 sq It (2,092 so m) j 12CANAvailable through Imperial Sprinkler Services 10-PVC MAINL ET IN OVALVEM NIFOLU 50%turfs t PANEL A / 0/. Tees/shrubs/flower o s U to 30 000 s It 13 2 790 s m P q , { 9 ) I ' CDNUUR FOR GROUND ROD E: ROUND Primary Contact: 11- L•Z BALL VALVE COUPLING CONNECTOR - 'Assumes a refill frequency of 4e weeks and waledng every other day. is requires more water used therefore wrij increases refill Frequency. This unit will-1 2 Emu 1' CONDurrs FLOW service larger areas when filled more frequently. Fertilizer requirements maybe reduced when used in cOnjuncfiari with anorganic bio-stimulant. _ ._, : FINISHED GRADE LU1S Muriel aaaG INSTALL DIRECTION ARROW DING TO WA'I RR FLOW DIRF,CTION ARROW ` T 12 _ PEA GRAVEL caoun0 FDR E 1485 North Manassero St., Anaheim, CA 92807 (I CU. FT. SWEEP RES TEZt�0c' -CTd CONOUn FGR 9 l0 13-PVC MAINLiNEFROMBACKFLOR PREVENTER Ys�a" kaLP (Standard Capacity Model) ELF µ0NTROLLERRIBPhone (714) 696-7535 11 12 4- PRESSURE RELEFVALVE END VIEW Fax (714) 696-7545 Warranty: Five (5) years except under heavy pressure conditions or excessive temperature conditions where summer 3/4•C. 1i'6 ITEMSNOTE. temperatures exceed detailed F ran C). Heavy pressure conditions are when static line pressure exceeds 50 PSI (5.5 Eo ppDFESS10ryq/ AP OVE Y: CITY OF FONTANA EZ-FD 3 4, T6, 7 AND S ARE INCLUDED WITH THE bars). See other detailed warranty and installation limitations at www.ezflonjection.com/resources/warranty. s,�"Q �pQpO SANDDy F�e� �, EZ-FLU SYSTEM, ITEM 11 IS PURCHASED % (QJ w E 4l m L O SEPARATELY. Includes: Does Not Include: ITY ENGINEER EZ-FLOFERTILIZINGSYSTEM No.s7752 DATE IRRIGATION CONTROLLER Bypass fitting, tubing and tubing clamps Irrigation coupling connector. An approved EZ-FLO connection CICARDO SANDOVAL MODF,L NUMBF,R - E7,003-CX Pressure relief valve - rated 150 PSI (10 bars) is the minimum required. An EZ-FLO ball valve connector (CBV) is OF ESS/ pp OVED CITY ®F FONTANA A R ED Y: CITY OF FONTANA 2.5 GALLON CAPACITY Two 2 EZ Shutoff valves pR 0 () required for low flow conditions, sloped 0� �! pA0FE5S10 NOTTOSCALF, (D 2012 EZFLO FERTILIZING SYSTEMS, INC. landscapes or when using viscous products, such as heavy y,�OQ `aQ09 SA,ypO Fyn ,GQOa p0 SAH� /zg �r/'r•� REVIEWED BY: organic bio-stimulants, to ensure proper proportioning. `t r� �, •/ �� �q y sPgTF crva OQa�F DATE OF LAST REVISION: 5005 m OF CALIp s-a2-is STD. PLAN N0. SHT 3 OF 3 IRRIGATION CONTROLLER CITY ENGINEER No. 51752 " CITY ENGINEER DATE No. 51752 DATE IRRIGATION CONTROLLER This system connects directly to the irrigation piping after the back now prevention device and the tank is design gi for use underconstant t pressure. RICARDO $ANDOVAL RICARDO SANDOVAL to feed 's patented fl kler and drip it gation zo try adjusts to changes in water pressure and water flowgrower changing finings. This product is designed * * y; X. design dboth o she deliveryof drip irrigation t are designated for as D municipal, sports fold, golf course, grower and residential applications. This system is REVIEWED BY: �,� REVIEWED BY: � S CITY /�_ A code for them back w products that are designated as Wont hazardous. T CIVIL �a Br cNll \P V I T Y O F FONTANA sgTf Of CAUFgA� DATE OF LAST REVISION: 6-22-i s STD. PLAN N0. 5005 SHT 1 OF 3 4%F OF CAUFgpa DATE OF LAST REVISION: s-22-15 STD. PLAN N0. 5005 SHT 2 OF 3 s code compliant back Cuunn breaker device is required ba for installation. Installation quIred cco local and state plumbing codes. Unless otherwise 7��T specified, a pressure vacuum breaker is the minimum back flow prevention device required according to University of Southern California -Foundation LANDSCAPE PLANS Coll Underground Service Alert for Cross Connection Control and Hydraulic Research. �1 �TT� SCALE, before you dig AVENUE � il of least 2 days 02016, EZ-FLO Fertilizing Systems Phone (866) 393-5601 FOR (91 fi) 652-5754 www.ezflofertilizing.com S DRAWN BYi IERRA AVSTA. 73+00,39 TO STA. 79+9I.12 AS SHOWN DESIGNED By. IIZRIGATION NOTES, LEGEND &DETAILS Kn Call 6 FERTILIZER INJECTOR (7) AUTOMATIC CONTROLLER CHECKED BY. APPROVED BY, rDV�G,'ND, L Cell before you dig. S I T E S C A P E S Landscape Architecture and Planning 3190 B2 Airport Loop Drive Costa Mesa, CA 92626 Richard Polharl License CA-#2782 (949) 644-9370 (714) 210-3140 FAX � O 0*� all 0 � o U W o O 0 a LMMMMMMMMMMMMMMMMi 0 O U W H Q U O 3 � Z Q �� �pNDSC,gpf ���0 pip A. PO(H4�G976 0 � � Q � PC * LSPC 19-000009 DATE 12/18/18 JOB # 18-023 L 5 6 OF 17