Loading...
HomeMy WebLinkAbout5812LT-1A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REV. I REVISION DESCRIPTION J ENGR. J DA TE I CITY I DATE CITY OF FONTANA SUMMIT A T R 05ENA TRACT 20214-4 ON -SITE STREET LIGHT PLAN TRA C T BOUNDAR Y SCf- X A . F. 3 4 9 90 95 16 21 23 1 Z2 2 -- 5 8 -- 110 -- 17 20 IT �— J 24 LOT AI - 1 F- -1 F- —I19 �9 * 6 7 * 92 13 18 I 27 25 I I . O11_ O Qc 12 PETR U5 13_ LANE 14 15 — — _ - h 28 26 of ,} I . I. �. ... 29 * 1 30 , 102 0 J L 97 96 J L 91 90 85 J L I 1 CZ 98 95 -- 92 89 -- 86 Q 7 31 100 99 94 93 88 87 N 33 11 ii ' i i i I 32 LOT E 35 I 69 70 75 76 89 82 i LOT e DECORA TI VE LED STREET ; W I ; 7i 74 — — , , 34 LIGHT BY OTHERS PER ; W I ; 68 — — — — 77 80 83 Q, � Q 36 DWG. NO. 5767-L T (TYR) : 3 Z ' ' 1 o * I ' 0� 67 �F �F F 72 73 78 79 84 �. ,„ i1 39 u 1. »� 38 11 12 — 1 _ 14 15 16 5TAC5 LEA LANE ;. �. ... 49 ,} I 0 0 LI 40 66 J L 69 60 ;� J ---L 55 54 L 49 48 — 42 �I ,65 — — 62 59 � — — 56 53 — — 50 43 I � — i v 1 47 El { 64 63 58 57 52 59 46 45 44 ' I, / El I, II 1 --- I I ------,—o---------------- o---------#1-- -_{' ---------------------------------- 1 -------------------------------------- ---- ------------------------ \ _-- '� \ ---- - - - - -- - - - - - - - - - - - ------ - — -:�. VENETO DRIVE ---------------- _________________�_ T_ T hr771 SHOULD CONSTRUCTION OF REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND C4RRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH STANDARDS IN EFFECT. PREPARED fOR• LENNAR HOMES 980 MON TECI TO DRIVE, SUITE 302 CORONA, CA 92879 (951) 817-3545 FAX (951) 817-3650 CONSTRUCT/ON NOTES & OUANT/TY EST/MATE NO. DESCRIPTION INSTALL LED DECORATIVE STREET LIGHT (60 WATTS) SCE# 10184034, CARPINTERIA POLE (25 FT. LUMINAIRE HEIGHT) AND TEARDROP FIXTURE (WITH BROWN JASPERPOLE AND BLACK ARMS TEARDROP) PER CITY STANDARD PLAN NO. 404 CASE 1 BASIS Of BEARIN[- THE BASIS OF BEARINGS FOR THIS SURVEY IS THE EAST LINE OF THE SE 114 OF SECTION 19, ALSO BEING THE CENTERLINE OF SIERRA AVENUE, PER PARCEL MAP NO. 19434, P.M.B. 242197-98. BEING: N00 3332 "W BENCHMARK: CAL TRANS BENCHMARK 118-17 BRASS DISK LOCATED IN S.C.E. TOWER LEG LOCATED 343' N/0 /-210, 0.2 MILES WEST OF SAN SEVAINE ROAD. ELEVA TION= 1428.6 09 Q W - DECORA TIVE LED STREET LIGHT BY OTHERS PER DWG. NO. 5763-L T UNIT QUANTITY EA 5 ENGINEERING 357 N. SHERIDAN STREET SUI TE 117 K o LAND PLANNING CORONA, CALIFORNIA 92880 TEL. (951) 279-1800 SURVEYING FAX (951) 279-4380 Engineering, Inc. 08108119 AMIR H. FALLAHI , RCE 55534 DA TE / <) ESS/p O No. 55534 m Exp. 12/31 /19 clW\- F CALIF PROJECT SITE �Py CASA GRANDE/GF� soF o SUMMIT A VENUE yG F Q � FOOTHILL FREEWAY 210 Q � BASELINE ROAD c� NOT TO SCALE DEVELOPER/OWNER LENNAR HOMES 980 MONTECI TO DRIVE, SUITE 302 CORONA, CA 92879 (951) 817-3545 FAX (951) 817-3650 VICINITY MAP ENGINEER K&A ENGINEERING, INC 357 N. SHERIDAN STREET, SUI TE 117 CORONA, CA 92880 PHONE.- (951) 279-1800 CITY OF FONTANA, UTILITY NOTIFICATION LI5T CITY OF FONTANA 8353 SIERRA A VENUE FONTANA, CA 92335 (909) 350-6632 SO. CALIF. GAS COMPANY 1981 W. LUGONIA AVENUE REDLANDS, CA 92374 (909) 335- 7967 EMERGENCIES.- (800) 427-2200 SO. CALIF. EDISON COMPANY 300 N. PEPPER A VENUE RIAL TO, CA 92376 (909) 820-5598 - UNDERGROUND (909) 875-5100 - TRANSMISSION (213) 637-1233 - PIPELINES (909) 357-6505 - DISTRIBUTION FONTANA WA TER DEPARTMENT 8440 NUEVO A VENUE FONTANA, CA 92335 (909) 822-2201 AT&T 12505 N. MAINSTREET,. RANCH CUCAMONGA, CA 91739 (909) 646-9644 SPRINT 17171 FOOTHILL BLVD. SUITE A FONTANA, CA 92335 (909) 346-2980 TIME WARNER CABLE 9820 SIERRA AVENUE SUITE G FONTANA, CA 92335 (877) 816-0046 SUNESYS, L L C 1325 PICO STREET #106 CORONA, CA 92881 (951) 278-0400 UNDERGROUND SERVICE ALERT (800) 422-4133 STREET LIGHT GENERAL NOTES 1. LIGHTING LAYOUT SHALL COMMENCE AT STREET INTERSECTIONS. STREET LIGHT SPACING BETWEEN INTERSECTIONS SHALL BE AS SPECIFIED IN THE TABLE ON SHEET 3 AND LOCATED AT THE PROLONGATION OF PROPERTY LINES. STREET LIGHT LAYOUTS SHALL BE REVIEWED FOR CONFLICTS WITH OTHER UTILITIES (CATCH BASINS, FIRE HYDRANTS, TRANSFORMERS, ETC.) 2. USE OF BRAND NAMES IN THESE STANDARDS IN NOT INTENDED TO RESTRICT COMPETITION. EQUIVALENT PRODUCTS MAY BE SUBSTITUTED WITH THE APPROVAL OF THE CITY ENGINEER. 3. SIDEWALK WIDTHS TO BE PER APPROVED STREET IMPROVEMENT PLANS A MINIMUM OF 4' UNOBSTRUCTED SIDEWALK CLEARANCE IS REQUIRED. 4. ANY CHANGE IN LOCATION OF STREET LIGHTS FROM THE APPROVED PLANS OR STANDARDS IS SUBJECT TO WRITTEN APPROVAL BY THE CITY ENGINEER. 5. ALL STREET LIGHTS SHALL HAVE AN ANTI -GRAFFITI COATING. LEGEND PROPOSED FIRE HYDRANT �1 PROPOSED CATCH BASIN INDICA TES PROPOSED DECORA TI VE LED STREET LIGHT - SCE PART > #10184042 (100 WATTS) CARPINTERIA POLE (30 FT. LUMINAIRE - , HEIGHT) AND TEARDROP FIXTURE (WITH BROWN JASPERPOLE AND BLACK ARMS TEARDROP) PER CITY STANDARD PLAN NO. 404 CASE 1 INDICA TES PROPOSED DECORA TI VE LED STREET LIGHT - SCE PART #10184034 (60 WATTS) CARPINTERIA POLE (25 FT. LUMINAIRE -1 `01 HEIGHT) AND TEARDROP FIXTURE (WITH BROWN JASPERPOLE AND BLACK ARMS TEARDROP) PER CITY STANDARD PLAN NO. 404 CASE I Al COMMUNITY MARKER 26' PRI VA TE ALLEY EASEMENT WATER METER CITY OF FONTANA, CALIFORNIA ON -SITE STREET LIGHT PLAN P DESIGNED BY. SUMMIT AT ROSENA SCALE. JS AS NOTED TRACT NO. 20214-4 DRAWN BY DA TE: ° By AUGUST 2019 0 CHECKED BY.• APPROVED B : «%f'�SX'Q►' 8/22/19 DRAWING NO: AF A IF 5812-L T a 0 CITY ENGINEER RCE 51152