HomeMy WebLinkAbout5742-11SYMBOL LIST GENERAL NOTES 1. THESE PLANS ARE DIAGRAMMATIC ONLY. FOLLOW AS CLOSELY AS POSSIBLE. REFER TO ARCHITECTURAL DRAWINGS FOR DETAILS, STRUCTURAL DETAILS, EXACT EQUIPMENT AND OUTLET LOCATIONS. 2. DO NOT SCALE THE ELECTRICAL DRAWINGS FOR LOCATIONS OF ANY ELECTRICAL DEVICES OR EQUIPMENT, 3. CONSTRUCTION TERMINOLOGY, AND THE STANDARDS OF INSTALLATION REQUIRED BY THESE CONTRACTOR DOCUMENTS ARE BASED ON PUBLISHED STANDARDS OF N.E.C.A. (NATIONAL ELECTRICAL CONTRACTORS ASSOCIATION), NATIONAL ELECTRICAL SAFETY CODE, AMERICAN NATIONAL STANDARDS INSTITUTE DOCUMENTS, NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION, UNDERWRITERS LABORATORIES, AND THE CALIFORNIA ELECTRICAL CODE. SUBMITTAL OF BID INDICATES THE CONTRACTOR IS FAMILIAR OF THESE STANDARDS AND THE REQUIREMENTS NECESSARY TO PERFORM ALL THE WORK AS SET FORTH IN THESE CONTRACT DOCUMENTS AND ACCEPTS THE CONDITIONS. 4, CONTRACTOR SHALL VERIFY EXISTING SITE CONDITIONS AND EXACT LOCATIONS OF SERVICE FACILITIES BEFORE SUBMITTING BID. SUBMITTAL OF BID INDICATES CONTRACTOR ACCEPTS THE CONDITIONS UNDER WHICH HE SHALL BE REQUIRED TO PERFORM HIS WORK. 5. ALL UTILITY WORK (POWER) SHALL BE IN COMPLIANCE WITH THESE DRAWINGS AND THE REQUIREMENTS OF THE SERVING UTILITY COMPANY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE SERVING UTILITY TO RECEIVE COMPLETE INFORMATION ON THEIR REQUIREMENTS PRIOR TO THE SUBMISSION OF THE BID. THE ACT OF SUBMITTING THE BID SHALL CONSTITUTE ACCEPTANCE OF FULL RESPONSIBILITY BY THE CONTRACTOR TO INSTALL SERVICE IN COMPLIANCE WITH THE SERVING UTILITY AND THESE CONTRACT DOCUMENTS. 6. THE CONTRACTOR SHALL INSTALL THE SERVICE IN COMPLIANCE WITH THE SERVING UTILITY COMPANY, AND SHALL PAY ALL CHARGES LEVIED BY THE SERVING UTILITY COMPANY FOR HIS SERVICE EXCEPT THE FIRST BILLING DEPOSIT. WHERE THE CONTRACT DOCUMENTS ARE MORE RESTRICTIVE, THE DOCUMENTS SHALL GOVERN. ALL ITEMS SUCH AS SERVICE CONDUIT, CONDUCTORS, DUCTS, CONCRETE PADS, TRANSFORMERS, RISERS, MANHOLES, PULL BOXES, AND PROTECTIVE COVERING FROM SERVICE LOCATION SHALL BE INSTALLED AND VERIFIED WITH THE SERVING UTILITY COMPANY. 7. ELECTRICAL CONTRACTOR SHALL PAY FOR AND SECURE ALL NECESSARY BUILDING PERMITS, UTILITY COMPANY CHARGES. IF REQUIRED, CONTRACTOR SHALL COORDINATE AND PAY FOR ALL TEMPORARY ELECTRICAL SERVICE CHARGES WITH THE BUILDING DEPARTMENT, SERVING UTILITY, AND OWNER. 8. SUBMIT SHOP DRAWINGS FOR ALL MAJOR PIECES OF ELECTRICAL EQUIPMENT, WHICH INCLUDES, BUT NOT LIMITED TO: SWITCHGEAR AND LIGHT FIXTURES 9. SHOP DRAWINGS SHALL BE SUBMITTED WITHIN THIRTY DAYS AFTER AWARD OF THE CONTRACT. THE CONTRACTOR SHALL SUBMIT EIGHT COPIES OF A COMPLETE LIST OF MATERIALS AND EQUIPMENT INCLUDING MANUFACTURER AND MODEL NUMBER PROPOSED FOR THE JOB. SHOP DRAWINGS SHALL INCLUDE JOB DESCRIPTION, ARCHITECT AND ENGINEER IDENTIFICATION, AND ALL DATA WITH CAPACITIES, SIZES, DIMENSIONS, CATALOG NUMBERS, MANUFACTURER'S BROCHURES, AND SUPPORT DATA. 10. THE CONTRACTOR SHALL HAVE THE OPTION OF ROUTING RACEWAYS UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. 11. CONTRACTOR SHALL PROVIDE ALL J-BOXES, PULL BOXES, ELLS, OFFSETS ETC., FOR A COMPLETE, CODE APPROVED, INSTALLATION OF ALL CONDUIT. FOOTAGE SHOWN ON ELECTRICAL SINGLE LINES AND RISER DIAGRAMS ARE FOR CALCULATION PURPOSES ONLY, AND ARE NOT FOR BIDDING PURPOSES OR MATERIAL TAKEOFF. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REVIEW AND TO COORDINATE WITH MECHANICAL, FIRE PROTECTION, AND PLUMBING DRAWINGS FOR DUCTS, LINES, AND EQUIPMENT. 12. THE CONTRACTOR SHALL PERFORM HIS WORK IN ACCORDANCE WITH ALL GOVERNING STATE, COUNTY, LOCAL CODES, O.S.H.A., THE PRESENTLY ADOPTED NATIONAL ELECTRICAL CODE, AND PRESENTLY ADOPTED CALIFORNIA ELECTRICAL CODE (C.E.C.) 13. THE CONTRACTOR SHALL COORDINATE WITH OTHER TRADES AS TO THE EXACT LOCATION OF THEIR RESPECTIVE EQUIPMENT. SUPPLY POWER AND MAKE CONNECTIONS TO MOTORS AND EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS AS INDICATED ON THE SINGLE LINE DIAGRAM, ELECTRICAL DRAWINGS, AND DRAWINGS OF OTHER TRADES. REVIEW THE DRAWINGS OF OTHER TRADES FOR CONTROL DIAGRAMS, SIZE AND LOCATION OF EQUIPMENT. DISCONNECT SWITCHES, STARTERS, WIRING, CONTROLS, AND CONDUIT FOR MECHANICAL AND PLUMBING OPERATIONS SHALL BE PROVIDED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING MANUFACTURER'S SHOP DRAWINGS PRIOR TO ROUGH -IN IN ALL CONDUIT TO THIS EQUIPMENT. 14. CONTRACTOR SHALL USE MATERIALS THAT ARE NEW, AND OF THE SAME MANUFACTURER FOR FOR EACH CLASS OR GROUP OF EQUIPMENT. MATERIALS SHALL BE LISTED AND APPROVED BY THE (U.L.) UNDERWRITER'S LABORATORIES FOR THE USE AND ENVIRONMENT, AND SHALL BEAR THE INSPECTION LABEL WHERE SUBJECT TO APPROVAL. MATERIALS SHALL MEET WITH THE APPROVAL OF THE DIVISION OF INDUSTRIAL SAFETY, AND ALL GOVERNING BODIES HAVING JURISDICTION. MATERIALS SHALL BE MANUFACTURED IN ACCORDANf.'Z WITH APPLICABLE STANDARDS ESTABLISHED BY A.N.S.I., U.L., N.E.M.A., AND N.B.F.U. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. 15. THE CONTRACTOR SHALL EXCAVATE ALL TRENCH DEPTHS AND WIDTHS PER THE C.E.C. AND SHALL COMPACT ALL EXCAVATIONS IN A CONTINUOUS LAYER OF NOT MORE THEN 6" COMPACTED DEPTH TO THE REQUIRED DENSITY OF NINETY PERCENT (90%). THE CONTRACTOR SHALL ATTAIN THE SPECIFIED COMPACTION DENSITY BY MAINTAINING THE OPTIMUM MOISTURE CONTENT OF THE FILL MATERIAL 16. P.V.C. CONDUIT SHALL BE USED UNDERGROUND ONLY, IF APPROVED BY LOCAL CODE. INSTALL PER ALL REQUIRED LOCAL CODES. ALL CONDUIT SWEEPS, RISERS, AND STUBS ABOVE GRADE SHALL BE I.M.C. WITH HALF -LAPPED TAPE COVERING OR FACTORY INSTALLED P.V.C. COATING. ROUTE ALL UNDERGROUND CONDUITS AROUND PROPOSED BUILDING AND FUTURE BUILDING LOCATIONS. 17. ALL CONDUIT SHALL BE INSTALLED CONCEALED WHERE PHYSICALLY POSSIBLE. 18. ALL CONDUCTORS OF EVERY SYSTEM SHALL BE PERMANENTLY TAGGED IN COMPLIANCE WITH O.S.H.A. 19. THE COMPLETE ELECTRICAL SYSTEM SHALL BE GROUNDED IN ACCORDANCE WITH THE PRESENTLY ADOPTED EDITION OF THE C.E.C., ARTICLE #250. OVERALL STREET PLAN 20. CONDUCTORS SHALL BE CODE GRADE, 600 VOLT CLASS, COPPER, MARKED 24" ALONG IT'S LENGTH SHOWING MANUFACTURER'S NAME, MAXIMUM ALLOWABLE VOLTAGE AND SIZE. CONDUCTORS SHALL BE TYPE "rHWN" (WET) OR " fHHN" (DRY). DELIVER CONDUCTORS TO THE JOB SITE IN UNBROKEN PACKAGES. 21. EXACT LOCATION OF ALL ELECTRICAL DEVICES AND EQUIPMENT SHALL BE COORDINATED WITH THE ARCHITECTURAL ELEVATIONS, DETAILS, OR SECTIONS PRIOR TO INSTALLATION. ALL ELECTRICAL DEVICES AND EQUIPMENT SHALL BE RECESSED IN WALLS UNLESS OTHERWISE NOTED. 22. WHERE A CONFLICT OCCURS BETWEEN THESE NOTES, THE SPECIFICATION OR THE ELECTRICAL DRAWINGS ISSUED AS A PART OF THESE DOCUMENTS, THE MORE STRINGENT REQUIREMENT SHALL PREVAIL. 23. AT THE COMPLETION OF THE PROJECT, PROVIDE THE OWNER WITH ONE (1) SET OF COMPLETE, UP TO DATE, "AS -BUILT" REPRODUCIBLE DRAWINGS , SHOWING ACTUAL DEPTHS OF UNDERGROUND CONDUIT RUNS AT ALL LOCATIONS. ALL BROCHURES, OPERATING MANUALS, CATALOGS, SHOP DRAWINGS, ETC. SHALL BE TURNED OVER TO THE OWNER AT PROJECT COMPLETION. 24. AFTER DATE OF ACCEPTANCE BY OWNER, THE COMPLETED PROJECT SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR. ANY WORK, MATERIAL OR EQUIPMENT FOUND TO BE FAULTY DURING THAT PERIOD SHALL BE CORRECTED IN A TIMELY MANNER, UPON WRITTEN NOTIFICATION, AT THE EXPENSE OF THE ELECTRICAL CONTRACTOR. 25. SERVICE PEDESTAL SHALL BE PROVIDED WITH RATINGS, COMPONENTS, AND FEATURES IN STRICT ACCORDANCE WITH THE SERVING UTILITIES AND CODE ENFORCING AGENCY, ELECTRICAL DRAWINGS AND SPECIFICATIONS. THE MAIN SWITCHBOARD AND DISTRIBUTION PANELS CONSIST OF A COMPLETELY ENCLOSED SELF-SUPPORTING, FLOOR STANDING STRUCTURE, OF THE REQUIRED NUMBER OF FORMED VERTICAL PANEL SECTIONS. PROVIDE BOLTED FRAMES AND INSULATING BLOCK TO SUPPORT THE MAIN HORIZONTAL BUS FOR SHORT CIRCUIT STRESS AS INDICATED ON THE DRAWINGS. ALL BUSSING SHALL BE 100% RATED MADE WITH COPPER HAVING A CURRENT DENSITY OF 1,000 AMPS PER SQUARE INCH, PROVIDED WITH SILVER PLATED BUS CONNECTIONS. PROVIDE A Xs INCH THICK BY 2 INCH HIGH BY FULL LENGTH GROUND BUS WITHIN 12 INCHES OF NEUTRAL BUS AND CONNECT WITH A REMOVABLE LINK (CONNECTED IF SHOWN ON SINGLE LINE DIAGRAM). VENTILATED ENCLOSURE WITH NEMA 3R EXTERIOR ENCLOSURE SHALL BE STAINLESS STEEL WITH VANDALPROOF LOCKING PAD LOCK COVER 26. PANEL BOARDS SHALL BE COPPER "BOLT -ON" TYPE. COMPONENTS AND FEATURES SHALL BE IN STRICT ACCORDANCE WITH THE SERVING UTILITIES, CODE ENFORCING AGENCY, ELECTRICAL DRAWINGS, AND MAIN SERVICE MANUFACTURER AND OPERATING CHARACTERISTICS. FINISHED GRADE VOLLTAGE METALLIC HI( U.G. CONDUIT DETAIL SCALE N.T.S. Underground Service Alert SECTION 4216/4217 OF THE GOVERNMENT CODE REQUIRES A DIG ALERT IDENTIFICATION eEFORE y0 o °o NUMBER BE ISSUED BEFORE A PERMIT TO EXCAVATE WILL BE VALID FOR YOUR DIG ALERT I.D. NUMBER CALL UNDERGROUND SERVICE ALERT TOLL FREE 1-800-227-2600 TWO WORKING DAYS BEFORE YOU DIG P�QY4C { M RF � �Q., yy� '� ~ No.69984 A sT Exp.9-30-18 \e CIVt\, 9oF CA01 TERRY M. RE REV. REVISION DESCRIPTION DATE ENGR. CITY I DATE LIGHTING FIXTURE SCHEDULE REFER TO DIVISION 1, GENERAL REQUIREMENTS, REGARDING PRODUCT OPTIONS AND SUBSTITUTION. WHERE THREE OR MORE MANUFACTURERS ARE LISTED IN THE FOLLOWING LIGHTING FIXTURE SCHEDULE, SUBSTITUTION WILL NOT BE CONSIDERED. WHERE PRODUCTS ARE LISTED BY NAMING ONE OR MORE MANUFACTURERS, WITHOUT "OR EQUAL" PROVISION FOR SUBSTITUTION, CONTRACTOR SHALL INCLUDE ONLY SPECIFIED PRODUCTS IN BID. REQUEST FOR SUBSTITUTION WITHIN 35 DAYS FROM THE DATE OF THE NOTICE TO PROCEED WILL ONLY BE CONSIDERED IN ACCORDANCE WITH DIVISION 1 OF THESE CONTRACT DOCUMENTS. DESCRIPTION LAMPS I VOLTS I MANUFACTURER CATALOG # 1 MOUNTING 7 NO. WATTS I TYPE SURFACE TO GRADE LENSED LE.D. MEDIUM SPREAD LUMASCAPE FLUSH TO GRADE S 14 UP LIGHT 1 34 L.E.D. 53K 120 LS452LEDP-27W4-85-ME- 1 2 34 23-Q-09-CB-LS637-K SURFACE TO GRADE LENSED LE.D. SPOT UP LIGHT LUMASCAPE FLUSH IN GRADE 1 T 1 34 L.E.D. 53K 120 LS452LED-27W4-85-NR- 1 2 34 23-Q-09-CB-LS637-K NOTES: 1 AIM FOR BEST COVERAGE AFTER INSTALLATION. ® LOCATE FIXTURE PER E-2.0 - DETAIL #4 FROM TRUNK OF TREE AND OREINT FIXTURES PER PLANS . TKE ENGINEERING, INC. 2305 CHICAGO AVENUE RIVERSIDE, CA 92507 (951)680-0440 MERINO FAX (951) 680-0490 NNER R.C.E. No. 69984 LANDSCAPE IMPROVEMENTS FOOTHILL BOULEVARD OLEANDER AVENUE TO 600' EAST OF CYPRESS AVENUE - CONDUIT RUN CONCEALED BELOW GRADE, 3/4"C. MINIMUM. - 3 CONDUIT STUB OUT, CAP & MARK. © CONCRETE PULLBOX WITH BOLT -ON COVER. SIZE AS REQUIRED PER C.E.C. ® METER PEDESTAL REFER TO SINGLE LINE DIAGRAM. e SURFACE TO GRADE LIGHT FIXTURE W/ NARROW SPOT OPTICS - REFER TO FIXTURE SCHEDULE. ® SURFACE TO GRADE LIGHT FIXTURE W/ WIDE SPREAD OPTICS - REFER TO FIXTURE SCHEDULE. 1S LIGHT FIXTURE CALL OUT, "IS" INDICATES FIXTURE TYPE (REFER TO FIXTURE 1 3 34 SCHEDULE) "34" INDICATES TOTAL FIXTURE WATTAGE. - -2.0 3 DETAIL CALLOUT, "3" INDICATES DETAIL NUMBER "E-1" 1 3 E-1 INDICATES SHEET NUMBER. 2 O PLAN NOTE REFERENCE. QREVISION REFERENCE. CO CONDUIT ONLY, WITH PULL ROPE. WP WEATHERPROOF, NEMA 3R PROVIDE FURNISH, INSTALLED AND CONNECTED, COMPLETE. C CONDUIT E/G EQUIPMENT GROUND (GREEN) UG UNDERGROUND GEC GROUNDING ELECTRODE CONDUCTOR C.E.C. CALIFORNIA ELECTRICAL CODE N.E.C. NATIONAL ELECTRICAL CODE U.O.N. UNLESS OTHERWISE NOTED A.F.W. ABOVE FINISHED WALK. A.F.G. ABOVE FINISHED GRADE SLOPE CONCRETE AWAY FROM FIXTURE FINISHED GRADE UNFORMED CONCRETE. 20"x2ONIS" DEEP OR 20" DIAMETER x6"DEEP z 2500 P.S.I. 028 DAYS r � ® 0 N `. -IIIIIIIIII_ lz III -ICI III- \I- R BOLTS FOR ANCHON -I �-III III- III=III= CASTPLACE' III -III - - 4-WAY, 3/4" JUNCTION BOX, LOCATED DIRECTLY -III III- III -III-III UNDERNEATH OPENING N -III- -III- I I III III -III- IN PRE -INSTALLATION KIT, - III- ACTORY SUPPLIED).J-BOX -III-III I I I ISSERV CABLE- -III -III II III -III III -III I I III I I -I -III-I =III=1 III- I I I III INSTALLATION. I I 7" ELECTRICAL CONDUIT RUN BELOW GRADE. UP LIGHT DETAIL SCALE I N.T.S. SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. Wsmis OF Engineering Inc. I ElecMcal Engineennq & Consuhing 1 N U A 8048 Palm Ave JJ Highland. Ca. "' E 92346 909 864-0223 Fax 909 864-0280 o d james.corns@jcaeng.com SCALE i"=100'-0" CITY OF FONTANA, CALIFORNIA ELECTRICAL IMPROVEMENT PLANS E-1.0 DRAWN BY: FOOTHILL BOULEVARD MEDIAN IMPROVEMENTS SCALE: p,�,�, AS SHOWN DESIGNED BY: ELECTRICAL PLANS DATE: J.J.C. EL ICA SYMBOL LIST & G.N. SEPT. 2018 CHECKED BY: APPROVED DATE: DRAWING NO.: 11 J.J.R. - - - --- �, . 5742 14