HomeMy WebLinkAbout4804-1GENERAL NOTE5
1. ALL WORK SHALL BE /N ACCORDANCE WITH THESE PLANS, THE CITY OF
FONTANA STANDARD PLANS, THE CONTRACTOR PROVISIONS AND THE
STANDARD SPEC/F/CA BONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN
BOOK'). ALL REFERENCE SPEC/FICA TIONS AND STANDARDS SHALL BE THE
LATEST EDITION UNLESS OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT /S FOUND TO EXIST /N THE CONTRACT
DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE
PROVISIONS IN THE "GREEN BOOK" THE CONTRACTOR SHALL IMMEDIATELY
REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
J. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY
ENGINEER.
4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA
COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE
START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT
LEAST TWO WORKING DAYS PRIOR TO START OF ANY WORK /N PUBLIC
RIGHT-OF-WAY WITHIN THE CITY LIMITS CALL (909) 350-7610.
5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES,
METHODS AND PROCEDURES DESCRIBED /N THE STATE OF CALIFORNIA
MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS
OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN
BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL
TIMES.
7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCA VA 710N OR
TRENCH WORK FOR TRENCHES 5 FEET OR GREATER /N DEPTH FROM THE
CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
8. THE WALLS AND FACES OF ALL EXCA VA TIONS GREATER THAN FIVE (5) FEET
IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR
OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION
OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA TRENCHES LESS THAN
FIVE (5) FEET SHALL BE ALSO GUARDED WHEN THE POTENTIAL FOR GROUND
MOVEMENT
9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC
RIGHT-OF-WAY WITHOUT OBTAINING A SEPARA 7E PERMIT FOR THAT PURPOSE.
10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM
AVAILABLE INFORMA 710N. HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND
ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER
PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT
UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO DAYS BEFORE
EXCA VA TION.
11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY
COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC,
CABLE, TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER,
RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CAL TRANS.
ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS N077CE PRIOR
TO WORK AROUND THEIR FACILITIES
12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN
VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL
COORDINA TE WI TH THE APPROPRIA 7E WA TER COMPANY FOR VA VE OPERA TION
AND WA TER REQUIREMENTS
13. CURVE DA TA REFERS TO THE FACE OF CURB.
14. STA 770NING REFERS TO THE CENTERLINE OF STREET EXCEPTS WHERE
OTHERWISE NOTED.
15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER
TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN
GRADES THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION
OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING
CONSTRUCTION.
16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS,
MONUMENT TIES OR BENCHMARKS WITHOUT PRIOR NOTIFICATION TO THE CITY
ENGINEER.
17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING
SURVEY MONUMENTS, MONUMENT TIES AND BENCHMARKS, SHALL BE DONE
BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY
MONUMENTS THAT WILL DESTROYED AS A RESULT OF CONSTRUCTION SHALL
BE REPLACED. THE CONTRACTOR SHALL NOTIFY ENGINEER ONE WEEK PRIOR
TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR
LATER REPLACEMENT OF THE MONUMENT.
18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND
BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED
AT ALL TIMES /N THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY
VEHICLES
19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF
DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES
20. ALL GRADING OPERA 710NS SHALL BE DISCONTINUED WHEN SUSTAINED WIND
VELOCITIES EXCEED 25 MILES PER HOUR.
21. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT
OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT
TO THE RIGHT-OF-WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN
APPROVAL.
22. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE
CITY ENGINEER.
23. A GE07ECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION.
FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF
THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED.
24. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM
UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE
CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODABLE SWALES ENTERING
OR LEAVING IMPRO VEMEN TS
25. THE FINAL LOCATION AND WIDTH OF DRI VEWA Y APPROACH APRONS SHALL BE
APPROVED AT THE TIME OF CONSTRUCTION AND SHALL CONFORM TO THE
CITY OF FONTANA STANDARD DETAILS
26. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND
FINISH TO MATCH EXISTING CONCRETE.
27. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB
AT THE LOCATION OF THE SEWER LATERAL.
28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL
HAVE BEEN PLACED, INSPECTED AND APPROVED.
29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED
PRIOR TO PAVING OF STREETS
30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT
PA VEMENT PRIOR TO PLACEMENT.
31. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO
REVISION AND APPROVAL OF THE CITY ENGINEER AS DETERMINED BY SOILS
TESTS TAKEN AFTER COMPLETION OF ROUGH GRADING.
32. ACTUAL THICKNESS OF A.C. PAVEMENT AND/OR BASE COURSE MATERIAL FOR
STRUCTURAL STREET SECTIONS SHALL BE RECOMMENDED BY A GE07ECHN/CAL
REPORT AND SUBMITTED TO THE CITY OF FONTANA FOR APPROVAL UPON
COMPLETION OF ROUGH GRADING.
33. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE
RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION
OF PA VING.
QDV
TOLL FREE -qmmw"' DIAL 811
A PUBLIC SERVICE BY
UNDERGROUND SERVICE ALERT
31. UPON COMPLETON OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL
SIGNING, STRIPING, AND BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES
TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
32. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS
AND SIDEWALKS AFFECTED BY THE CONSTRUCT/ON TO TIE SATISFACTION OF
THE CITY ENGINEER.
33. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE
ENGINEER OF RECORD, WHO SHALL PROVIDED RECORD DRAWINGS TO THE
CITY ENGINEER.
PRIVATE ENGINEER'S NOTICE TO THE CONTRACTOR:
REV. REVISION DESCRIPTION
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTLITY PIPES, AND/OR
STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF
AVAILABLE RECORDS THESE LOCATIONS ARE APPROXIMATE AND SHALL BE
CONFIRMED BY THE CONTRACTOR, SO THA T ANY NECESSARY ADJUSTMENT CAN
BE MADE /N ALIGNMENT AND/OR GRADE OF THE PROPOSED IMPROVEMENT. THE
CONTRACTOR /S REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO
PROTECT ANY UTILITY LINES SHOWN AND ANY OTHER LINES NOT ON RECORD
OR NOT SHOWN ON THESE PLANS
CONSTRUCTION CONTRACTOR AGREES THAT /N ACCORDANCE W/ TH GENERALLY
ACCEPTED CONSTRUCTION PRACTICES, HE WILL BE REQUIRED TO ASSUME SOLE
AND COMPLETE RESPONSIBILITY FOR JOB SITE COND1 TIONS DURING THE
COURSE OF CONSTRUCTION OF THE PROJECT INCLUDING THE SAFETY OF ALL
PERSONS AND PROPERTY. THIS REQUIREMENT SHALL BE MADE TO APPLY
CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS
CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND
HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL
OR ALLEGED, IN CONNECTION WITH PERFORMANCE OF WORK ON THIS PROJECT
EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE DESIGN
PROFESSIONAL.
UNAUTHORIZED CHANCES AND USES
THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR OR
LIABLE FOR, UNAUTHORIZED CHANGES TO OR USE OF THESE PLANS ALL
CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY
THE PREPARER OF THESE PLANS
CONSTRUCTION STAKING NOTICE
THESE IMPROVEMENT PLANS HAVE BEEN PREPARED WITH THE INTENT THAT
THE FIRM OF K&A ENGINEERING INC. WILL BE PERFORMING THE CONSTRUCT/ON
STAKING FOR THE COMPLETE PROJECT. HOWEVER, IF ANOTHER ENGINEERING
AND/OR SURVEYING FIRM SHOULD BE EMPLOYED TO USE THESE PLANS FOR
THE PURPOSE OF CONSTRUCTION STAKING, NOTICE IS HEREBY GIVEN THAT THE
FIRM OF K&A ENGINEERING INC. WILL NOT ASSUME ANY RESPONSIBILITY FOR
ERRORS OR OMISSIONS, WHICH COULD HAVE BEEN AVOIDED, CORRECTED OR
MITIGATED IF K&A ENGINEERING INC. PERFORMED THE STAKING WORK.
CITY OF FONTANA, UTILITY NOTIFICATION LI5T
CITY OF FONTANA AT&T
8353 SIERRA AVENUE 22311 BROOKHURST STREET STE. 203
FONTANA, CA 92335 HUNTINGTON BEACH, CA 92646
(909) 350-6632 (714) 963-7964
SO. CALIF. GAS COMPANY SPRINT
1981 W. L UGONIA A VENUE 2592 DUPONT DRIVE
REDLANDS, CA 92374 /RV/NE, CA 92612
(909) 335-7967 (800) 659-9698
EMERGENCIES. • (800) 427-2200
TIME WARNER CABLE
50. CALIF. EDISON COMPANY 1500 AUTO CENTER DRIVE
300 N. PEPPER AVENUE ONTARIO, CA 91761
RIALTO, CA 92376 (909) 975-3439
(909) 820-5598 - UNDERGROUND
(909) 875-5100 - TRANSMISSION SUNESYS, L L C
(213) 637--1233 - PIPELINES 1325 P/CO STREET 11106
(909) 357--6505 - DISTRIBUTION CORONA, CA 92881
(951) 278-0400
WEST VALLEY WATER DISTRICT UNDERGROUND SERVICE ALERT
A TTN.• ENGINEERING DEPARTMENT
855 W. BASELINE ROAD (800) 422-4133
RIALTO, CA 92376
(909) 875-1804
R/W 60,
10'
0.5' 5' 3
SW
20'
2 C&G 1 AC
D
2q 2.1,
20'
TYPICAL STREET SECTION
TI=5.5
TRI VENTO PLACE & TURLEY WAY
N. T.S.
ENGR, DATE I CITY I DATE
C&G (2
CITY OF FONTANA
SUMMIT A T R 05ENA
ON -SITE STREET IMPROVEMENT PLAN
TRACT NO. 20214-2
I� II Ili
ABBREVIA TIONS
II II III
II II III �ti
j I I II III AB AGGREGA TE BASE
III � lti
' IIII III II AC ASPHAL T CONCRETE
PROJECT w
SITE
�Py
CASH
GR
ANDE
SUMMIT A VENUE
Q
FOOTHILL FREEW4 Y
Q
BASELINE ROAD v
II 11 II ` BC BEGIN CURVE
9 8 7 5 4 3 2 7 IIII I I I qI BCR BEGIN CURB RETURN
6 II 1 BVC BEGIN VERTICAL CURVE
CF CURB FA CE
27 \ C&G CURB AND GUTTER
C/L CENTERLINE
OAKVILLE -STREET -
��/ \\ \ \% CONC. CONCRETE
\� DRWY DRI VEWA Y
26
25 \\ \p\ EC END CUR VE
000010 \�� °�\ \ ECR END CURB RETURN
33 32 31 30 29 28 27
77 r \� \\ EVC END VERTICAL CURVE
Q or �\ ELEV ELEVA TION
7 7s T. EXl \\ \ \\\ EXISTING
72 _ 1 \\\ �\ \\�\ FL FLOW LINE
TRIVENTO PLACE \\��� y \\\
FS FINISHED SURFACE
\\ \I\ GB GRADE BREAK
73 HP HIGH POINT
1 24
-424
16 17 18 19 20 21 22 \I\I 1\ �II LF LINEAR FOOT
I 23 \
74 ■ II LOS LINE OF SIGHT
I
LP LOW POINT
N » 1
NTS NOT TO SCALE
-- - --------- - _-- _=�\N PAL PROPERTY LINE
VENETO -- DRIVE- - - 3 P.C.C. PORTLAND CEMENT CONCRETE
/r
PROP PROPOSED
POINT OF VERTICAL
R 0214-r � ' p� PV/ INTERSECTION
r R/W RI GHT- OF- WA Y
SD STORM DRAIN
DEVELOPER/OWNER ENGINEER INDEX MAP
LENNAR HOMES K&A ENGINEERING, INC
980 MONTEC/TO DRIVE, SUITE 302 357 N. SHERIDAN STREET SUITE 117 SCALE: 1 =100
CORONA, CA 92879 CORONA, CA 92880
(951) 817-3545 PHONE: (951) 279-1800
FAX (951) 817-3650
R
R/W
10' ;
5' 0.5'
SW
3
R/W
SOUTH
10'
I5' I5'
3 SW
PREPARED fOR:
SHOULD CONSTRUCTION OF REQUIRED
IMPROVEMENTS NOT COMMENCE
WITHIN TWO YEARS OF THE DATE OF LENNAR HOMES
APPROVAL SHOWN HEREON AND SUITE 302
SU , IVE
CARRIED FORTH IN A DILIGENT MANNER, CORONA, 980 MONTECITO DRSU
THE CITY ENGINEER MAY REQUIRE
CA 92879
REVISIONS TO THE PLANS TO BRING (951) 817-3545
THEM INTO CONFORMANCE WITH FAX (951) 817-3650
STANDARDS IN EFFECT.
30'
20'
60'
30'
20'
2 C&G 1 AC
D
2q 23'
TYPICAL STREET SECTION
TI=5.5
OAKVILLE STREET
N. T.S.
C&G (2
R/W
NORTH
CONSTRUCTION NOTES & QUANTITY ESTIMATE
VICINITY MAP
NOT TO SCALE
SF
SQUARE FOOT
ST
STREET
STA
STA TION
STD
STANDARD
SW
SIDEWALK
T
TANGENT
TC
TOP OF CURB
VC
VERTICAL CURVE
LEGEND
NO.
DESCRIPTION
UNI T
QUANTITY
CONSTRUCT 4" MIN. AC PAVEMENT OVER 12" MIN. OF 95% COMPACTED NATIVE
SF
69,740
1
SUBGRADE (SEE GENERAL NOTES 31 & 32) & CITY STD. PLAN NO. 401
TON
1,640
Q__
CONSTRUCT 6" P.C.C. CURB & GUTTER PER CITY STD. PLAN NO. 1000
LF
3,330
0__
CONSTRUCT 4" P.C.C. SIDEWALK PER CITY STD. PLAN NO. 1006 (WIDTH = 5)
SF
15,280
4�
CONSTRUCT LOCAL DEPRESSION PER CITY STD. PLAN NO. 3003 (CASE PER PLAN)
EA
6
CONSTRUCT CURB RETURN ACCESS RAMP PER CITY STD. PLAN NO. 1003
EA
2
CONSTRUCT RESIDENTIAL DRI VEWA Y APPROACH PER Cl TY STD. PLAN NO. 1002,
SF
5,740
SHEET 1 OF 2
7�
INSTALL DECORATIVE LED STREET LIGHT PER STREET LIGHT PLAN
EA
8
BASIS OF BEARING ENGINEERING J57 N. SHERIDAN STREET
SUITE 117 ovESS/o
THE BASIS OF BEARINGS FOR THIS SURVEY IS THE EAST LINE OF THE SE ' LAND PLANNING CORONA, CALIFORNIA 92880 �o eR �q�
1/4 OF SECTION 19, ALSO BEING THE CENTERLINE OF SIERRA AVENUE, TEL. (951) 279-1800
PER PARCEL MAP NO. 19434, P.M.B. 242/97-98. SURVEYING FAX (951) 279-4380
Fll
BEING: N003332"W Engineering, Inc. � No. 55534
Exp. 12/31/19
BENCHMARK:
CAL TRANS BENCHMARK 8-17 . 4 sTgTC I V I \-
F
BRASS DISK LOCATED IN S.C.E. TOWER LEG LOCATED 343' N/0 I-210, 0.2 07/29/2019 OF CALF
MILES WEST OF SAN SEVAINE ROAD. AM/R H. FALLAHI , RCE 55534 DA TE
ELEVA TION= 1428.6 09
DESIGNED BY.•
JS/BB
DRAWN B Y.-
JS/A C/JC
CHECKED B Y.-
AF
210
PROPOSED BOUNDARY
EXISTING CENTERLINE
PROPOSED CENTERLINE
PROPOSED RIGHT OF WAY
PROPOSED SIDEWALK
PROPOSED LINE OF SIGHT (LOS)
PROPOSED AC PA VEMEN T
SHEET INDEX
SHEET NO.
DESCRIPTION
1
TITLE SHEET
2
TURLEY WAY PLAN & PROFILE
3
OAKVILLE STREET PLAN & PROFILE
4
7RIVENTO PLACE PLAN & PROFILE
MCN18-0761ELPC19-000014
z
CITY OF FONTANA, CALIFORNIA
0
ON -SITE STREET IMPROVEMENT PLAN N
0
SUMMIT AT ROSENA - TRACT NO. 20214 2 SCALE.
AS NOTED
TITLE SHEET DA TE:
JUL Y 2019
APPROVED o ���✓� 8122119 DRAWING N0:
DATE a
CITY ENGINEER RCE 51152 4
5804
0
0