HomeMy WebLinkAbout5842LT-1GEI ERAI_ NOTES FOR STREET LIGI-rr M-ANS
1. LIGHTING LAYOUT SHALL COMMENCE AT STREET INTERSECTIONS. STREET LIGHT SPACING
BETWEEN INTERSECTIONS SHALL BE AS SPECIFIED IN THE TABLE ON SHEET 3 AND
LOCATED AT THE PROLONGATION OF PROPERTY LINES. STREET LIGHT LAYOUTS SHALL
BE REVIEWED FOR CONFLICTS WITH OTHER UTILITIES (CATCH BASINS, FIRE HYDRANTS,
TRANSFORMERS, ETC.)
2. USE OF BRAND NAMES IN THESE STANDARDS IS NOT INTENDED TO RESTRICT
COMPETITION. EQUIVALENT PRODUCTS MAY BE SUBSTITUTED WITH THE APPROVAL OF
THE CITY ENGINEER.
3. SIDEWALK WIDTHS TO BE PER APPROVED STREET IMPROVEMENT PLANS. A
MINIMUM OF 4' UNOBSTRUCTED SIDEWALK CLEARANCE IS REQUIRED.
4. ANY CHANGE IN LOCATION OF STREET LIGHTS FROM THE APPROVED PLANS OR
STANDARDS IS SUBJECT TO WRITTEN APPROVAL BY THE CITY.
5. ALL STREET LIGHTS SHALL HAVE AN ANTI —GRAFFITI COATING.
PRIVATE ENGIIN'S NOTE TO CONTRACTOR
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES, CONDUITS,
OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF THE
AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING
UTILITIES EXCEPT AS SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED
TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN ON
THESE DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND
RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN ON
THESE DRAWINGS.
CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY
FOR JOB SITE CONDITIONS DURING COURSE OF CONSTRUCTION OF THIS PROJECT,
INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS REQUIREMENT SHALL
APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND THAT
THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE CITY OF FONTANA, THE
OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED,
IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR
LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER.
U11L" CONTACTS
SAN BERNARDINO COUNTY FLOOD CONTROL
825 E. THIRD STREET, ROOM 140
SAN BERNARDINO, CA 92415-0835
PHONE: (909) 387-8256
ATTN: TOM WILLIAMS
FONTANA WATER COMPANY
15966 ARROW ROUTE
FONTANA, CA 92355
PHONE: (909) 822-2201
ATTN: BRENDA FOWLER
SOUTHERN CALIFORNIA GAS COMPANY
1981 W. LUGONIA AVE.
REDLANDS, CA
PHONE: (909) 335-7965
ATTN: ED SANIILLAN
AT&T
1265 VAN BUREN ST. #180
ANAHEIM, CA 92807
PHONE: (714) 666-5614
ATTN: LEE QUEST
SOUTHERN CALIFORNIA EDISON
7951 REDWOOD AVENUE
FONTANA, CA 92336
PHONE: (909) 549-5345
ATTN: JEFF HUDSON
TIME WARNER
17777.CENTER COURT DR. 8TH FLOOR
CERRITOS, CA 90703
PHONE: (562) 677-0263
ATTN: JOHN CHRIS11ANSEN
FONTANA UNITED SCHOOL DISTRICT
9680 CITRUS AVENUE
FONTANA, CA 92335
PHONE: (909) 357-5000 X 29455
ATTN: SHERRI WHITTEN
INLAND EMPIRE UTILITY AGENCY
6075 KIMBALL AVENUE
CHINO, CA 91708
PHONE: (909) 993-1696
ATTN: LIZA MUNOZ
BASIS OF BEARINGS:
THE BASIS OF BEARINGS FOR THIS SURVEY IS
THE CALIFORNIA STA TE PLANE COORDINA TE
SYSTEM (CCS83), ZONE 5, NORTH AMERICAN
DA TUM 1983 (NAD83) BASED LOCALLY ON
CONTINUOUSL Y OPERA TING REFERENCE
STATIONS (CORS) "EWPP" AND "GISA" AS
SHOWN HEREON (BASIS OF BEARINGS.•
S 8235'10.9410" E ). ALL BEARINGS SHOWN
HEREON ARE GRID BEARINGS.
BENCH MARK:
CHISELED BOX IN EASTERL Y TOP OF CURB
TAMARIND AVENUE, 60' SOUTH OF TAMARIND
COURT, 500' SOUTH OF SL0VER A VENUE. AS
SHOWN ON CITY OF FONTANA STREET
IMPROVEMENT PLANS P.M. NO. 16264, DWG.
NO. 4768.
ELEVA77ON = 1077.44'
TOLL FREE -qmmi 1-800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
REV.
m_lw -19momp- -'� � A = � m � IL_ _'Im � � a
106 TAMARINID
FONTANA, CA
INDEX MAP.
EXISTING STREET LIGHT
❑ PROPOSED (41 WATT) LED STREET LIGHT
EXISTING UTILITY POLE
RELOCATED UTILITY POLE
F.H. = FIRE HYDRANT
PROPOSED FIRE HYDRANT
REVISION DESCRIPTION I DATE I ENGR. I CITY I DATE
TRFSIG
= TRAFFIC SIGNAL
= SIGN
- PB =
PULL BOX
WM =
WATER METER
TELEPHONE PEDESTAL
TRANS
PAD = TRANSFORMER PAD
ELEC VAULT = ELECTRIC VAULT
WV =
WATER VALVE
SMH =
SEWER MANHOLE
SDMH
= STORM DRAIN MANHOLE
1 TELMH
= TELEPHONE MANHOLE
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
PLANS TO BRING THEM INTO CONFORMANCE WITH
STANDARDS IN EFFECT.
QROFESS/QNgI
* R.C.E. NO. 56155 r-
�� &p. 12-31-20 Q
�F C A\-�F
VICINITY MAP
N. T. S.
♦s ti 11 ' 1 • •
O INSTALL LED STREET LIGHT (41 WATT) SCE #10205809. . . . . . . . . . . . . . . . . . . . . . 2 EA
(CASE 1) PER CITY OF FONTANA STD. NO. 404.
O EXISTING POLE TO BE REMOVED AND OVERHEAD FACILITIES TO BE UNDERGROUND.. . 4 EA
SHEET INDEX
1
TITLE SHEET
2
TAMARIND AVENUE STREET LIGHT IMPROVEMENT PLAN
Prepared Under The Supervision Of
aieneS Engineering, lnc.
ClV1L ENG/NEER/NG -LAND SURVEYING
14349 FIRESTONE BOULEVARD
LA MIRADA, NIA PH.(714)521-4811 CALIFOFAX(714)521-4173 DRAWN BY:
AR
AC
��Aust 26, 2019 CHECKED
R INHARD STEN EL DATE
R.C.E. 56155 — EXP. 12/31 /20 HIA
CITY OF FONTANA, CALIFORNIA
STREET LIGHT IMPROVEMENT PLAN
OAKMONT TAMARIND SCALE:
10694 TAMARIND AVENUE AS SHOWN
DATE:
DRAWING NO.; 1Zi
�R.CE. 51152 DATE 5842 LT
2
Last Update: 7/24/19
0:\3400-3499\3479\3479STLT01.dwg