Loading...
HomeMy WebLinkAbout5843-7N SLOPE OF STREET Irrigation System Maintenance Procedures IRRIGATION NOTES IRRIGATION LEGEND x x x While the system is designed to operate automatically, a regular maintenance schedule DIAGRAMMATIC PLAN SYMBOL MFG. MODEL NO. DESCRIPTION RAID. GPM PSI PRECIP.RATE FLUSH VALVE TYP. P x is necessaryto prevent and address failures in the system as well as ensure that the THIS SYSTEM IS DIAGRAMMATIC. ALL PIPE, VALVES, ETC. SHOWN (SEE DETAIL) ( ) AIR RELIEF VALVE (TYP.) TYPICAL DRIPLINE LAYOUT AS PER DETAIL p y WITHIN PAVED AREAS ARE FOR DESIGN CLARIFICATION ONLY 19 RAINBIRD (2) RWS-B-C-1401-GRATE-P ROOT WATERING SYSTEM .5 SEE PSI .70"/HR (SEE DETAIL) e x system operates in a manner that meets or exceeds the MAWA values provided. AND SHALL BE INSTALLED IN PLANTING AREAS AND JOINT OR (2) 1401 BUBBLER ON 1/2" OR TREE BUBBLER ON RISER LOSS CALC. TRENCHES WHEREVER POSSIBLE. SCH. 80 RISER WITH HUNTER Any broken or malfunctioning irrigation system components should be replaced with SPRINKLER ADJUSTMENT REQUIRED 1/2" HC-50E-50F CHECK VALVE - - - - - - - - - - WHEN PIPES ARE ON -GRADE the same components, or an equal or superior equivalent. THE IRRIGATION CONTRACTOR SHALL FLUSH AND ADJUST ALL _ _ `� • -� �� _ - - - SPRINKLER HEADS FOR OPTIMUM PERFORMANCE AND RAINBIRD XFS-P-06-18-100 DRIP LINE SYSTEM .5 SEE PSI .43"/HR Upon completion of the project, the following measures should be performed by PREVENT OVERSPRAY ONTO WALKS AND ROADWAYS AS MUCH Per 100s.f. LOSS CALC. property management at intervals noted below: AS POSSIBLE. ARC IS SHALL FIT THE EXISTING SELECTING THE BEST SITE CONDITIONS. -� RAINBIRD XFS-P-06-18-100 DRIP LINE SYSTEM .5 SEE PSI .43"/HR . 24" T 24" TYPYP. CONTRACTOR TO USE PRESSURE COMPENSATING SCREENS Per 100s.f. LOSS CALC. Weekly: OF TREE During weekly landscape maintenance operations, the maintenance personnel should -� RAINBIRD XFS-P-06-18-100 DRIP LINE SYSTEM .5 SEE PSI .43"/HR WHEN RADIUS IS REDUCED MORE THAN FIFTY PERCENT (50°/D). Per 100s.f. LOSS CALC. SEE CHART BELOW SEE CHART BELOW look for signs of runoff, erosion and plant die off due to irrigation system failures. If FIELD CONDITIONS FOR MAX. LENGTH OF DRIP LINE FOR MAX. LENGTH OF DRIP LINE g p g y DO NOT WILLFULLY INSTALL THE SPRINKLER SYSTEM AS RAINBIRD XFS-P-06-18-100 DRIP LINE SYSTEM .5 SEE PSI .43'/HR issues are detected, they should be brought to the attention of the maintenance Per 100s.f. LOSS CALC. INDICATED ON THE DRAWINGS WHEN IT IS OBVIOUS IN THE NOTES: supervisor and property management for timely correction. DRIP IRRIGATION NOTES SLEEVE AT ALL ROAD CROSSINGS (TYP) Isle P,a a m am unI agml dD FIELD THAT UNKNOWN OBSTRUCTIONS OR GRADE (1) MAINLINE SLEEVE LOCATE SERVICE LATERAL IN EACH DRIP FOR IRRIGATING AREAS ON SLOPE GREATER THAN 4:1, THE CONTRACTOR SHALL INSTALL RAINBIRD P 1 N.I n N Rpadnp z4 s Ind DIFFERENCES EXIST AND SHOULD BE BROUGHT TO THE Nominal.6 0.9M N IndI0.6 Ig.91 N 1 alFkwfgpm: XFSPCV-06-18 FOR SHRUB OR XFSPCV-06-12 FOR TURF APPLICATION FOR THE ENTIRE VALVE. BURY DRIPLINE AREA AT CENTER, LOCATE (1) FLUSH Dez De 155 374 14 os oc o4 Monthly: ATTENTION OF THE CONTRACTING OFFICER. IN THE EVENT (1) WIRE SLEEVE VALVE AT EACH END OF PLANTED AREA AS IS ss2 2]s ass 414 ii4 uD @4 20 44a 319 'E' a s03 68 All irrigation and master valves shall be visually inspected b a roe management THAT THIS NOTIFICATION IS NOT PERFORMED, THE ON SLOPE WITHIN 5' OF PAVEMENT/DG PAVING EDGE. SEE NOTES FOR EXCEPTIONS PER DETAIL-(2) FLUSH VALVES PER AREA. 46 441 Ew 5, 11 a1s ssG a g Y p Y property a mi ... I, Nse sss 2ss sED 4U1 , mz, .2 ma CONTRACTOR MUST ASSUME FULL RESPONSIBILITY FOR ANY MARK SLEEVE CROSSING ON FACE OF CURB LOCATE AIR RELIEF VALVE AS REQUIRED w5B 41r 2Rs " E,N e '41D nD, ea representative while the valve is under operating conditions. All control valves and THE CONTRACTOR WILL NEED TO FIELD LOCATE THE AIR RELIEF VALVES AT THE HIGHEST LOCATIONS bo d svn wD_ eio __ i vaa stry `us F 2eo L al+ _ `__ REVISIONS REQUIRED. WITH AN "IR" STENCIL. BY DETAILS '- -- -` filters should be visually inspected and cleaned as required and in accordance with ANY AREA WITH DRIP IRRIGATION SYSTEM REQUIRES LONGER ON EACH DRIP LINE SYSTEM. �) DRIPLINE THAN MAXIMUM LENGTH, THE DRIP IRRIGATION manufactures specifications. All leaks shall be promptly reported to a landscape SWING JOINTS SHALL BE INSTALLED AS MULTIPLE DRIP AREAS. maintenance representative so that the valve may be repaired or replaced in a timely INSTALL ALL HEADS WITH DOUBLE OR TRIPLE SWING JOINTS, FLUSH VALVES ARE TO BE INSTALLED AT THE END POINT OF ALL DRIP LINE SYSTEMS AND AT THE EXTREME END 1 �T V �T DRIP �T�1 �T T 7 fashion with the minimum amount of leaking water exposed to open air. USING STREET ELLS, AS PER DETAIL. OF EVERY DRIP SYSTEM. THE CONTRACTOR SHALL INSTALL (2) RAINBIRD OPERIND (MPN: #X17500) OPERATION 1 TYPICAL PICAL PARKWAY DRIP SYSTEM STET M LAYOUT O lJ T MIMMUM PRESSURE AND MAXIMUM GALLONS INDICATORS PER DRIP VALVE. ONE AFTER THE DRIP VALVE AND ONE AT THE END OF THE MANIFOLD SYSTEM. All Root Watering Systems are to be visually inspected to insure that all locking grates REQUIRED CONTRACTOR TO EVALUATE THE PRECIPITATION RATES OF DRIP LINE AGAINST SOIL TYPE/ INFILTRATION RATE are being reasonably kept free of debris. All grates that are not kept reasonably free of THE SPRINKLER SYSTEM DESIGN IS BASED ON A MINIMUM ON REQUIRED SOIL REPORT. ANY NECESSARY EQUIPMENT CHANGES SHALL BE BROUGHT TO THE ATTENTION OF RAINBIRD DRIP LINE MODEL - SEE LEGEND debris are to be reported to a landscape maintenance representative. All Root Watering OPERATIONAL PRESSURE AND A MAXIMUM DEMAND AT THE THE LANDSCAPE ARCHITECT FOR FURTHER DIRECTION 12 6 Systems that have their locking grates damaged or missing are to be reported to a POINT OF CONNECTION, AS NOTED ON THE PLAN. BEFORE 1 3 1a I, INSTALLING THE SYSTEM, CHECK POINT OF CONNECTION AND Fv RAINBIRD FLUSH VALVE ASSEMBLY - SEE DETAIL 2 r1/ LJ landscape maintenance representative so that the locking grate may be repaired or IMMEDIATELY NOTIFY CONTRACTING OFFICER IF PRESSURE IS replaced in a timely fashion. aR RAINBIRD AIR RELIEF VALVE - SEE DETAIL CONTROL 6 p y NOT AS NOTED OR THE REQUIRED GALLONS PER MINUTE IS DR PONE 2KRE NNEcn �' NOT AVAILABLE. H NIBCO BRASS BALL VALVE (LINE SIZE) T-585-70 (3/4"-2") / T-580-70-66 (2-3/4"-3") MAINTENANCE LOG WATER LINE UNDER PAVING 4" AND LARGER TO BE FEBCO NRS SERIES GATE VALVE - LINE SIZE. Keep a log of all inspections and maintenance performance on the irrigation system (Updated co to be provided to Property Manager on a monthly basis ALL MAINLINE UNDER PAVING SHALL BE INSTALLED 24" RAINBIRD EFB-CP-R-PRS-D SERIES REMOTE CONTROL VALVE W/ PRESSURE DEEP. ALL LATERAL LINES UNDER PAVING SHALL BE SCH 40 copy p p y g y ) REGULATOR &PURPLE HANDLE COVER -SIZES INDICATED ON PLANS , " FOR PA PVC AND INSTALLED 24" DEEP. ALL LINES TO BE INSTALLED SET PRESSURE REGULATOR MODULE @ TOTAL PSI OF OPERATING PRESSURE + PSI LOSS AT LATERAL PIPE. i° 12" FOR TURF Overall Landscape Maintenance PTOCedUTOS IN SLEEVE 2X DIA. OF LATERAL LINE. O RAIN BIRD 33 DNP LOCKING W/ PURPLE RUBBER CAP, QUICK COUPLER. SYSTEM COVERAGE At a minimum, the following items should be addressed on a regular basis as required THE IRRIGATION CONTRACTOR IS TO ADJUST HEAD ® RAINBIRD 100-EFB-CP BRASS REMOTE CONTROL VALVE FOR DRIP SYSTEM W/ 1" SCH. 40 BALL VALVE \ ^ per city code & fuel modification requirements: LOCATIONS IN THE FIELD IN ORDER TO GUARANTEE 100% & RAINBIRD PRB-QKCHK-100 1" PRESSURE REGULATING QUICK CHECK BASKET FILTER AND COVERAGE. CONTRACTOR TO CONTACT THE CONTRACTING 200 MESH STAINLESS STEEL SCREEN. INSTALL PURPLE HANDLE COVER. IV Monthly OFFICER PRIOR TO ANY MAJOR CHANGE(S) RESULTING IN Dead, dying and diseased vegetation should be replaced with equivalent plant material ADDITIONAL COST TO THE OWNER. WATER METERS - REFER TO CIVIL PLAN w/ similar hydrozone requirements, provided that the replaced vegetation does not SUPPLEMENTAL TREE IRRIGATION - result in mixing higher water use plants with low water use plants in the same TREES WHICH HAVE NOT BEEN SUPPLIED WITH A ROOT Q 2" WILKINS 375 XL SERIES REDUCED PRESSURE BACKFLOW PREVENTER 3a8a8�j___ hydrozone. ZONE WATERING SYSTEM IN DRIP IRRIGATED AREAS ARE W/ 2" WYE STRAINER -SEE DETAILS TO RECEIVE (4) PC-05 W/ PC DIFFUSER CAPS SPACED O AUTOMATIC CONTROLLER LOCATION - SEE NOTE ON PLANS T� 4 Invasive plant species should be eradicated as required. EQUALLY IN 24" DIA. AROUND TRUNK OF EACH TREE AND ePa 9��oa8e�� og&° TIED INTO THE DRIP SYSTEM DATA INDUSTRIAL'- 228PV2005 2" FLOW SENSOR 0 Plant material should be maintained in order to avoid obstruction of motorists views. DRIPLINE INSTALLATION AT TREES ® EZFLO-EZ003-CX FERTILIZER INJECTOR CONTRACTOR TO INSTALL DRIPLINE AT TREES TO PROVIDE INSTALL PER MFG. SPEC. IN CARSON L-SERIES VAULT DOWNSTREAM FROM FLOW SENSOR �i CONTROL ZONE KIT - SEE DETAIL Annually 48" SQ. CLEARANCE AROUND TREE TRUNK WHICH ARE ® 2" RAINBIRD EFB-CP SERIES MASTER VALVE W/ PURPLE HANDLE COVER AIR FLUSH PVC SCH ao ao-45 DEGREE Decorative rock should be replenished in order to maintain appropriate soil moisture INSTALLED IN DRIP IRRIGATED AREAS, MAINTAIN DRIP ASSEMBLY ASSEMBLY ELBOW levels. SYSTEM CONNECTIONS WITH APPROPRIATE DRIPLINE ILL'S (PURPLE) PVC SCH 40 LATERAL LINE- 12" COVER IN PLANTING AREAS, 24" COVER UNDER 3 PVC LATERAL LINE - SIZE PER LEGEND AND TEE'S � PAVING. -SIZES INDICATED ON PLANS 4 ® RAINBIRD AIR RELIEF VALVE KIT, Soil amendments consistent with the agronomic soils report for this project should be HEAD INSTALLATION ADJACENT TO HARDSCAPE 2 3 4 9 10 PLACED AT HIGHEST SPOTS IN THE FIELD applied in the manner prescribed in order to support and maintain healthy plant growth. (FONTANA) �SI� WHEN SLOPE IS GREATER THAN 4:1, INSTALL (BROWN) UVR PVC SCH40 LATERAL LINE ON GRADE ENT $ STAKED @ 10' O.C. - SEE PIPE ON GRADE DETAIL. ALL ABOVE GROUND IRRIGATION HEAD. ADJACENT T 1 5 PVC SCH 40 SLIP TEE J C O 12 11 6" PVC SCH 40 TEE (USE ELBOW O LAST Fuel Modification STREETS OR STREET ADJACENT IMPERVIOUS SURFACES ARE INSTALL KING BROS. KSC-T SERIES LINE SIZED INLINE SWING CHECK VALVES @ 8' INCREMENTS OF VERTICAL RISE. © SYSTEM ON THAT SIDE OF THE VALVE) TO BE INSTALLED 24" AWAY FROM THE EDGE OF THE IRRIGATION PIPE NOTE: Fuel Modification inspections should beperformed } Q7 REDUCER BUSHING p u d as prescribed to ensure that plant SURFACE. SEE SPRAY HEAD DETAILS FOR ADDITIONAL +IDENTIFY ALL ABOVE GROUND IRRIGATION WATER LINES BY CONTINUOUS LETTERING ON THREE INCH T I1-2" 8„ 3/4x 1/2" materials & trees remain compliant w/ the requirements of the approved "Fire INFORMATION. @6 PVC ADAPTER To Protection Master Plan for the Summit at Rosena" prepared b Dudek (May, 2018 (3' MINIMUM WIDTH PURPLE TAPE WITH ONE INCH BLACK LETTERING BEARING THE CONTINUOUS DRIP 600-CF-1 p p y ( y ) IRRIGATION AUDIT WORDING "CAUTION: RECYCLED WATER - DO NOT DRINK" PERMANENTLY AFFIXED AT FIVE FOOT 18" hod oROR00 0 0 PC DRIP LINE SEE LEGEND IRRIGATION AUDIT REPORT SHALL BE PERFORMED PER CITY INTERVALS ATOP ALL HORIZONTAL LATERAL LINE. a8 °o o`�8pg�g"Oog ° ° (@ FLUSH VALVE ASSEMBLY. SEE DETAIL. OF FONTANA REQUIREMENTS. + LATERAL LINE THAT IS WITHIN 5' OF PAVEMENT OR D.G. PAVING EDGE SHALL BE BURIED, 11 FINISH GLADE OR MULCH + LATERAL LINE THAT IS CROSSING ANY HARDSCAPE PAVING ON SLOPE SHALL BE BURIED IN SLEEVE. @ PC DRIPLINE CONNECTIONS. SEE DETAIL. STEP 1 2 , $�o$$Qo @ sysrEeiESRli TO �eceNo TO NEXT - - - (PURPLE) MAINLINE -SEE DETAIL FOR INSTALLATION DEPTHS. -SIZES INDICATED ON PLANS 1 1 {Mainlines (pressurized) 11/2 inch and smaller shall be Schedule 40 solvent -weld P.V.C. Mainlines (pressurized) 2 inch through 3 inch shall be Class 315 solvent -weld P.V.C. 2 DRIP LINE FOR SUBSURFACE INSTALLATION 4 CONTRACTOR TO USE INSTALL THRUST BLOCKS TO 2" MAINLINE, 1 2 O FINISH GRADE/TURF STEP 2 3 - - PVC SCH 40 WIRE SLEEVE. Lr _ n NOTE IF PVC SCH 40 TEE OR ELL PVC SCH 40 MAIN AND LATERAL LINE SLEEVE 2x DIA. OF PIPE ENCASED. - PROVIDE IF PUTTING LANDSCAPE DRIPLINE UNDER SOIL, VALVE NOT BURY MORE 12" FOR PA 18" FOR PA 2 OPERATION INDICATOR THAN 2" BELOW GRADE AND INCLUDE AIR RELIEF VALVE (SEE DRAWING- 12" FOR TURF 12" FOR TURF PVC LATERAL PIPE -SEE LEGEND O SLEEVES UNDER HARDSCAPE (CONCRETE /ASPHALT IN EXCESS OF 4' WIDE). "AIR RELIEF VALVE KIT"). IL BARB DRIP TEE: �- RAIN BIRD MODEL: OPERIND RAIN BIRD XFF-TEE 2 3 LANDSCAPE DRIPLINE TUBING: NOTE: BARD DRIP TEE: - O 6 5 * ALL CONTROL WIRE, LATERAL AND MAINLINE PIPE RUNS TO BE INSTALLED IN SEPERATE SLEEVES. RAIN BIRD BT50 (SEE LEGEND FOR SPECS.) STEP 3 * ALL SLEEVING TO BE SCH. 40 PVC. LANDSCAPE DRIPLINE TUBING: - BARB MPT MALE ADAPTER * SIZING RAIN BIRD LANDSCAPE DRIPLINE RAIN BIRD XFF-MA-075 3/4" MPT MALE ADAPTER (SEE LEGEND FOR SPEC.) OR RAIN BIRDXFF-MA-050 1/2" MPT MALE ADAPTER -WIRE SLEEVES, MUST BE OVERSIZED LEAVING AMPLE ROOM FOR FUTURE WIRE ADDITIONS OR rl BARB DRIP ELBOW: 3 REPAIRS. RAIN BIRD XFF-ELBOW LANDSCAPE DRIPLINE TUBING: - PIPE SLEEVING TO BE 2 x DIAMETER OF PIPE ENCASED. FINISH GRADE RAIN BIRD LANDSCAPE DRIPLINE TIE DOWN STAKE: LANDSCAPE DRIPLINE TUBING: (SEE LEGEND FOR SPEC.) RAIN BIRD TDS-050 W/ BEND RAIN BIRD LANDSCAPE DRIPLINE i` a� STEP 4 7 INDICATES WATER REQUIREMENT (SEE LEGEND FOR SPEC.) a~ X INDICATES STATION NUMBER INSTALL 0 3' O.C. 8 X X` INDICATES CONTROLLER o0 X INDICATES GPM INDICATES VALVE SIZE 1. SLIP BASE SOCKET OVER ENDS OF WIRES. X� INDICATES HYDROZONE AREA (SQUARE FOOTAGE) LANDSCAPE DRIPLINE TUBING: 2. STRIP WIRES APPROX. 3/8" FROM ENDS - v/;///;//;//;//;�//��//;�//;�//;�//�//,�//; RAIN BIRD LANDSCAPE DRIPLINE TWIST TOGETHER. (SEE LEGEND FOR SPEC.) . 3PUT CRIMP SLEEVE OVER WIRE ENDS - EASY FIT COMPRESSION COUPLING: EASY FIT COMPRESSION COUPLNG: NOTE: CRIMP AND CUT OFF EXCESS WIRE. RAIN BIRD MDCFCOUP RAIN BIRD MDCFCOUP 1. INSERT BARB TRANSFER FITTING DIRECTLY INTO DRIPLINE TUBING. EASY FIT COMPRESSION FLUSH CAP: 2. VAN NOZZLE MAY BE SET TO CLOSED, OR IF IT IS DESIRED TO SEE SPRAY 4. APPLY SEALER TO OUTSIDE OF SEALING RAIN BIRD MDCFPCAP FROM THE NOZZLE, SET THE ARC TO Y4 PATTERN. THE FLOW FROM THE PLUG - FILL CAVITY WITH SEALER. EASY FIT COMPRESSION FLUSH CAP: NOZZLE, 0.3 GPM, SHOULD BE ACCOUNTED FOR IN THE SYSTEM DESIGN. 5. PULL BASE SOCKET OVER CRIMPED CON - RAW BDRIP IRD X COUPLING: RAAIIN BIRD MDCFCAP BARB MPT MALE ADAPTER 3. INSTALL (2) RAIN BIRD OPERIND (MPN #X17500) OPERATION INDICATORS NECTION AS FAR AS POSSIBLE, COMPLIANCE STATEMENT EASY FIT PURPLE COMPRESSION FLUSH CAP: RAIN BIRD XFF-MA-075 3/4" MPT MALE ADAPTER PER DRIP VALVE. ONE AFTER THE VALVE AND ONE AT THE END OF THE 6. PUSH SEALING PLUG INTO BASE SOCKET. BARB. MPT MALE ADAPTER MANIFOLD SYSTEM. HAVE COMPLIED WITH THE CRITERIA OF THE ORDINANCE AND RAIN BIRD MDCFPCAP OR RAIN BIRDXFF-MA-050 1/2" MPT MALE ADAPTER 7. PUSH WIRES TO END OF BASE SOCKET RAIN BIRD XFF-MA-075 3/4" MPT MALE ADAPTER APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER OR RAIN BIRD XFF-MA-050 1/2" MPT MALE ADAPTER INSTALLATION NOTE: TO ASSURE COMPLETE SEALING OF CONNECTION. IN THE IRRIGATION DESIGN PLAN 1. CONTRACTOR TO CONNECT LANDSCAPE DRIP LINE WITH XF DRIPLINE INSERT FITTINGS/CONNECTORS 8. RAIN BIRD "SNAP-TITE" WIRE CONNECTOR 2. CONTRACTOR TO INSTALL RAIN BIRD MDCFCOUP EASY FIT COMPRESSION COUPLING AT FLUSH VALVE OR APPROVED EQUAL.�� 3/19/19 3 PC DRIP LINE CONNECTIONS 4 DRIP OPERATION INDICATOR (5) WIRE CONNECTOR RICK POLHAMus LA112782 EXP. 10119 DATE City of Fontana Irrigation Controller Standard a0V iWlwv� 4'"111 w w u TM For Communities Facilities Districts ,. NOTE: ALL POWER WIRES, GROUND WIRES ETC. SHALL BE �.+� SEPARATELY SLEEVED AND SWEPT THROUGH ENCLOSED PAD WITH SCH 40 RIGID CONDUIT (CFD ) EXACT LOCATION OF CONTROLLER SHA1L BE AGREED ALL SLEEVING SHALL BE A MINIMUM OF 18" BELOW UPON 61 FOISON, aTr ISNDSCAPE INSPM70R AND FINISHED GRADE. ALL SLEEVING IS A GRAPHIC REPRESENTATION CONTRACTOR PRIOR TO ANY TRENCHING OR O OF A IYP. INSTALLATION. WIRE PLACEMENT CONT. `fr"s Toro Sentinel controller installed in an approved stainless steel Edison meter box enclosure. N a 1 T SIZE OF GONG. SLAB - 8" THICK 1 - FINISHED GRADS ,. ;; i it , . ,t�? 4 �s� /p4 REBARS AT 12' o.a TrP '° r a Contact Green Product Sales with the following numbers for the City of Fontana u. n � 2 VALVE BOX & COVER 20" L X 16W X I2T-I ` gT.,,;ti.�` a );1,{n- '# ,r;„ ` :;-„ 1?m : s+ GENERAL NOTES: meter/controller. S&. 3 - PROPORTIONING CAP WITH FEED PRDYIOF UMA METER AND sw/2P MAN C/e W%H RE INDICATED ADJUSTMENT KNOB iD in) e} 12 Q ON Opawwcs e" Mk X 12" D. PROVIDE PANFLBOARD WHERE INDICATED ON DRAWINGS. BOTTOMLESS GROUND WELL Downlasatlable CAD e g d prod h pa incanons WITH PARKWAY COVER, Fontana art # for a 48 station COnLTOBer 4 EZ-FLOSHUT OFT VALVES WITH Iableat V,,,w am fa,nli.iPoc mrsa a:P 3 p PROVIDE IRRIGATION CONTNDLLER CABINET WHERE INDICATED FILL WITH PEA GRAVEL DISCONNECT WASHERS ON oRAwlNcs �� � �� - ESB48-U2-MPEA1610K-0BI-VRA FZI30I (*b 5 EZ-FLO MODEL EZ003 CX FERTILIZING SYSTEM rn a Features TERMINATE AT ExlmoN IRANDaoLE. PER S.C.E.s.aE. coMPArvr ar0. VERY( EMU LOCATION AND TERMINADON RED. WITH S.C.E. CO. 4 RE ARE 3 21'L X 8" D X I L" H PRIOR To WEwCHING 4 TYP 5/8-DIA X 10' DRIVEN GROUND 2 Tank Capacity - Liquid: Approx. 2.5 Gal. (9.5 liters) ROD PER ARTICLE 250-81 4 4 Tank Capacity -Water Soluble Fertilizer: Up to 15 -18 lbs. (6.8 -8.2 kg) Model #MPS-A7 6-1 OK CONDUIT AN CON DUMR9 WIIH AGE BNAED ONNN "IMZtAII,UEC CONDUn OF T990 NEC Required items to be included with each controller installed: F FERTILIZER OUT - CONNECT TIONS AR Minimum Flow Requirements: 2.5 gallons/hour (9.5 liters/hr.) I OP 1'D GRI EN C AP ANDIONS ON Ad�ustable Feed Ratio Range: 15,000 1/Slow setting to 400:1/Fast setting 1. W 12-XB Toro Sentinel 12 station wireless output board, level 3 sure protection with `✓ Till 5 PROPORTIONING CAP AND COUPLING J 9 9 9 tp g Water alume to Empty Tank: 37,500 gal (142 kl)/Slow setting XB-Spread Spectrum Radio 7 WATERIN - CONNECT BLACK 1,000 gal (3.8 kl)/Fast setting f TUBE TO BLUE CONNECTIONS ON Unit Dimensions (LWH)a 21"x 8" x ll" (53cm x 20cm x 28cm) IRRIGATION CONTROL r ,,..'4�G1- �;; PROPORTIONING CAP AND COUPLING Valve Box Minimum (LWH): 24" x 13" x 16" (61cm x 33cm x 41 cm) aoneo I PROVIDE 20 AMP 2. TK-3170 Kenwood hand held remote w/ charger set to City of Fontana frequency III METER FACE 2 PROVIDE BREAKER } u '0.`- -----j Approx. Weight: 11 lbs. (4.9 kg) I I $ REE FOR NEW PUMPS M programming r WHERE APPLICABLE 8 - 1 /4 TUBING CLAMP BOTH THE GREEN METER I PUMP MOUNTING i TEMPLATE RA MOON LNG AND BLUE COUPLING TUBING CONNECTIONS I srraoNe Box 2P ^ sroNnL sue 3. AfteT controller installation contact Green Product Sales to schedule inspection for 7 Suggested Landscape Coverage under normal watering conditions*: MODEL NO. SB- 24SS/120v PAVER p ;1 I t2D/2ao certification x 4 APPROVEDBACKFTLL 100% turf Up to 15,000 sq f[ (1,395 sq m) I °2aGIR 75% turf/25% trees/shrubs/flowers. Up to 22,500 sq ft (2,092 sq m) PANEL Available through Imperial Sprinkler Services .S 10 PVC MAIN LINE TO VALVE MANIFOLD 50% turf150% trees/shrubs/flowers Up to 30,000 sq It (2,790 sq m) I. coNDun FOR GROUND ROD l INSTALLATION Primary Contact: $ 11 LZ BALL VALVE COUPLNG CONNECTOR- *Assumes a refill frequency of 4-6 weeks and watering every other day. Turf requires mole water and therefore increases refill frequency. This unit will IE D 2 E m I' CONDUITS FLOW INSTALL AL'CO}tUING TO WATER FLOW service larger areas when filled more frequently. Fertilizer requirements may bereduced when used in conjunction with an organic bio-sfimulanf. v FINISHED GRPBE LU1S Muriel 1485 North Manassero St. Anaheim CA 92807 3 s z DIRECTION ARROW > > 1 12 PEA GRAVEL (1 CU. FT.)SWEEP orvoulr FOR EZ003-CX Standard Capacity Model WIRES LEER GROUND FOR ELECTRIC L Phone (714) 696-7535 F p (may J *'13-PVC MAIN LINE FROM BACK FLOW PREVENTER 1� y ) END VIEW WIRES Fax(714) 696-7545 S, �.J 10 jl $ 12 14- PRESSURE RELEIF VALVE Warranty: Five (5) years except under heavy pressure conditions or excessive temperature conditions where summer �� a/+'q, 1#e NOTE: temperatures exceed 100' F (38` C). Heavy pressure conditions are when static line pressure exceeds 50 PSI (5.5 pROFESSID,yy /AP OVE Y: CITY OF FONTANA =x ITEMS SYSTEM. ITEM IRL INCLUASED TH THE bars). See other detailed warranty and installation limitations at www.ezflonjection.com/resources/warranty. �1�aRRO gANOpy� ��, � SEPARATELY. Includes: Does NotInclude: "� �` ^' ITY ENGINEER IRRIGATION CONTROLLER EZ-FLO FERTILIZING SYSTEM Bypass fitting, tubing and tubing clamps Irrigation coupling connector. An approved EZ-FLO connection No.51152 RICARDO SANDOVAL DATE MODEL NUMBER- EZ003-CX Pressure relief valve - rated 150 PSI (10 bars) is: the minimum required. An EZ-FLO ball valve connector (CBV) is PROF ESSIOgq AP OVED CITY OF FONTANA CITY OF FONTANA 2,5 GALLON CAPACITY Two (2) EZ Shutoff valves required for low flow conditions, sloped ,\v@� Rp0 SggO �`O� Q�� RRO SgyO /`Od ,/% avlL REVIEWED BY: K.S landscapes or when using viscous products, such as heavy pP oy c 5� x,P Op c �.,.��C% �'� / 8r �@ Nor To'SCATE Q 2012 EZ-FLO FERTILIZING SYSTEMS, INC. organic bio-stimulants, to ensure proper proportioning. W x s� $m„ ;; `" s� �F„ - grF OF CAII?RQ� DATE OF LAST REVISION: 6-22-15 STD. PLAN N0. 5005 SHT 3 OF 3 1 No. 51152 " CITY ENGINEER DATE IRRIGATION CONTROLLER `t No.51152 CITY ENGINEER DATE IRRIGATION CONTROLLER This system connects directly to the irrigation piping afterthe back flow prevention device and the tank is designed for use under constant pressure, RICARDO SANDOVAL RICARDO SANDOVAL EZ-FLO's patented flow process automatically adjusts to changes in water pressure and water flow without changing fittings. This product is designed * w REVIEWED BY: L * * REVIEWED BY: i to feed both sprinkler and drip Inigatien zones for commercial, municipal, sports field, golf course; grower and residential applications. This system is CML crvll SHT 2 OF 3 CITY O F FONTANA designed forthe delivery of products that are designated as non hazardous. �l9rP OF C0.UFOQR�P DATE OF LAST REVISION: 6-22-15 STD. PLAN NO. 5005 SHT 1 OF 3 Of CA /�jF L14 �\P DATE OF LAST REVISION: e-22-15 STD. PLAN NO. 5005 A codecompliant back pow prevention device is required for installation. Installation must follow local and state plumbing codes. Unless otherwise specified, a pressure vacuum breaker is the minimum back flow prevention device required acwrding to University of Southern California - Foundation DS (TAPE PLANS S Call Underground Service Alert for Cross Connection Control and Hydraulic Research. LANDSCAPE WAWN BYE AVENUE SCALE, at least 2 days 92016, FZ-FLO Fertilizing Systems Phone (866) 393-5601 Fax (916) 652-5754 www.ezfioferiilizing.com CYPRESS AVE1N AS SHOWN DESIGNED an STA. 10+00.00 TO STA. 43+26.25 DATE p p before you dig iRRIGATRION OTES, LEGEND &DETAILS �' ZI 17 Knott allarBoreyou 6 FERTILIZER INJECTOR 7 AUTOMATIC CONTROLLER `"""`D BY, ARPRBVEa an xx �T r� )w`11- 21 Call before you dig. 1MTE� % i 1 T E i C A P I S Landscape Architecture and Planning 3190 B2 Airport Loop Drive Costa Mesa, CA 92626 Richard Polhamus, License CA-#2782 (949) 644-9370 (714) 210-3140 FAX � W O � CIO M ® S^ ct O � Cd O � O n N O LU W H Z Z ^ U o Z L� E� �I` C..ApF Nrv@ �2782� ` Po *L,SPC 19-000011 DATE 12/18/18 JOB # 18-023 L 6 7 OF 21