HomeMy WebLinkAbout5821-LT-1LAYOUT1. LIGHTING 1SPACING
BETWEEN INTERSEC11ONS SHALL BE AS SPECIFIED IN THE TABLE ON SHEET 3 AND LOCATE):
AT THE PROLONGATION OF PROPERTY LINES. STREET LIGHT LAYOUTSBE REVIEWED
FOR CONFLICTS WITH OTHER UTILITIES (CATCH BASINS, FIRE HYDRANTS, TRANSFORMERS,
2. USE OF BRAND NAMES IN THESE STANDARDSNOT INTENDED TO RESTRICT COMPETITION.
EQUIVALENT PRODUCTS MAY BE SUBS11TUTED WITH THE APPROVAL OF THE CITY ENGINEER.
WIDTHS
3. SIDEWALK !, BE PER APPROVED STREET IMPROVEMENT ,. MINIMUM OF
UNOBSTRUCTED SIDEWALK CLEARANCE
REQUIRED.
4. ANY CHANGE IN LOCATION OF STREET LIGHTS FROM THE APPROVED PLANS OR STANDARDS
IS SUBJECT TO WRITTEN APPROVAL
RESPONSIBLETHE CIVIL ENGINEER SHALL NOT BE ,Y FOR THE CONTRACTORS'1
SUBCONTRACTORS' !MPLIANCE WITH THE "OCCUPATIONAL SAFETY A.i` HEALTH REGULATIONS'
OF THE U.S. DEPARTMENT OF LABOR OR WITH THE STATE OF CALIFORNIA DEPARTMENT OF
INDUSTRIAL • ! CONSTRUCTIONS SAFETY ORDERS.
CONTRACTOR FURTHER AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY
FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT,
INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY
CON11NUOUSLYAND NOi TO' !' 1 AND THAT THE
CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER
HARMLESS FROM ANY KIND AND ALL LIABILITY, REAL OR ALLEGED, IN CONNEC11ON WITH THE
PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR ANY LIABILITY ARISING FROM
THE SOLE NEGLIGENCE OF OWNER OR
I N m
r ! ` , • !ISTAMUNNINT11 1
!• r
1
SOUTHERN CALIFORNIA EDISOR
501 SOUTH MARENGO AVENUE
8353 SIERRA AVENUE
r
626-308-6313
ORLANDO !
FONTANA WATER COMPANY
GAS
11142 GARVEY AVENUE
THE GAS COMPANY
1918 WEST LUGONIA AVENUE
626-448-6183
REDLANDS,.2374
ATTN: LUIS MONTENEGRO
609-335-7715
II I I
DENNIS'i
TELEP-HONE
! •
CAM TELEMSION
TIME WARNER
TELECOM
-!.!
SUITE i
ONTARIO, CA 91761
909-456-3652
{`.
L
... _. �.. ',,�. .. I 7". �;-. ROVOIIIIIIIIIIIIIIIIIIIIIIIIIIIIII0 � �., i:. '; AN 3
TRACT.
?0?30
INDEX MAP
i.
AM
0192-242-58
FONTANA, CA 92335
CONSTRUCTION NOTES
QTY.
Ot
INSTALL STREET LIGHT (41W LED) PER CITY STD. PLAN. N0. 404
ZONING*
AND PER NOTES ON THIS DWG.
2 EA.
O
INSTALL ELECTRICAL PULL BOX.
4 EA.
SINGLE FAMILY RESIDENTIAL
�3
INSTALL 2° SCH 80 PVC CONDUIT WITH #6 WIRE 24" MIN. DEPTH IN PARKWAY,
AND 2" SCH 80 PVC CONDUIT WITH #6 WIRE AT ALL STREET AND DRIVEWAY CROSSING.
968 LF•
SHEET INDEX
O4
CONNECT TO POINT OF SERVICE WITH DUAL METERS ON SINGLE SERVICE PEDESTAL
Ie.
SHEET 1: TITLE SHEET
FOR STREET LIGHTS AND LANDSCAPING. (TO BE DETERMINED BY SCE)
2 EA.
SHEET 2: STREET LIGHT PLAN
O5 INSTALL STREET LIGHT (90W LED) PER CITY STD. PLAN. N0. 404
AND PER NOTES ON THIS DWG. 2 EA.
O6 REMOVE EXISTING LUMINAIRE. 1 EA.
UNAUTHORIZED CHANGES
AND USES.
CAU11ON: THE ENGINEER PREPARING THESE PLANS WILL NOT BE
RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES
TO OR USES OF +
--) 41W LED STREET LIGHT
" ----� 90W LED STREET LIGHT
-- -� CONDUIT WITH CONDUCTORS AND BONDING WIRE
EX. STREET LIGHT
TELEPHONESCE AND .i RELOCATION ANi REMOVAL SHALL REQUIRE
COMPANYSCE AND TEL PROCESSING AND APPROVALPRIOR ANY !r
66
ANASTASIA
AVENUE
w
PROJECT SITE
MERRILL
STREET
RANDALL
AVENUWE
W
C
SAN BERNARDINO
AVENUE
VALLEY
BOULEVARD
INTERSTATE 10
10
NTS
THOMAS
BROS. MAPS 2006 EDITION
COORDINATES PAGE 05 B3
mo
woom