HomeMy WebLinkAbout5809-5NOTE
CONTRACTOR TO VERIFY ELEVATION &
LOCATION OF EXISTING UTILITIES PRIOR TO
CONSTRUCTION & NOTIFY ENGINEER IF
DIFFERENT THAN PLAN.
NOTE
CONTRACTOR TO VERIFY ELEVATION &
LOCATION PRIOR TO CONSTRUCTION &
NOTIFY ENGINEER IF DIFFERENT THAN PLAN.
TOLL FREE
A PUBLIC
UNDERGROUND
mmw� DIAL 811
SERVICE BY
SERVICE ALERT
10+00
SHAFER COUR T
SEE SHEET NO 3
60'
30' 30'
20 20'
REV. I REVISION DESCRIPTION J ENGR. J DA TE I CITY I DATE
11 +00
SHOULD CONSTRUCTION OF REQUIRED
IMPROVEMENTS NOT COMMENCE
WITHIN TWO YEARS OF THE DATE OF
APPROVAL SHOWN HEREON AND
CARRIED FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE
REVISIONS TO THE PLANS TO BRING
THEM INTO CONFORMANCE WITH
STANDARDS IN EFFECT.
12+00
13+00
14+00
�0 1U a vvH icn
J0' .30'
60' ROYAL OAKS WAY
5TAC5 LEAP LANE
PREPARED fOR.•
BASIS OF BEARING -
THE BASIS OF BEARINGS FOR THIS SURVEY IS THE EAST LINE OF THE SE
114 OF SECTION 19, ALSO BEING THE CENTERLINE OF SIERRA AVENUE,
LENNAR HOMES PER PARCEL MAP NO. 19434, P.M.B. 242197-98.
980 MON TECI TO DRIVE, SUITE 302 BEING: N00'3332 "W
CORONA, CA 92879 BENCH MARK:
(951) 817-3545
FAX (951) 817-3650 CAL TRANS BENCHMARK #8-17
BRASS DISK LOCATED IN SC.E. TOWER LEG LOCATED 343' N/0 I-210, 0.2
MILES WEST OF SAN SEVAINE ROAD.
ELEVA TION= 1428.6 09
15+00
15+00
PEGASUS BAY PLACE
SEE SHEET NO 2
60'
ENGINEERING
LAND PLANNING
SURVEYING
Engineering, Inc.
AM/R H. FALLAHI , RCE 55534
J57 N. SHERIDAN STREET
SUI TE 117
CORONA, CALIFORNIA 92880
TEL. (951) 279-1800
FAX (951) 279-4380
0711112019
DA TE
No. 55534
Exp. 12/31 /19
CIVIL
PROFILE 5CALE
HORZ.• 1 " = 40'
VERT• 1 " = 4'
4 " SEWER LA TERAL S
L 0 T NO.
DESIGN STA
"AS —BUILT" STA
BACK WA TER
YES
NO
27
15+70.59
X
28
15+67.51
X
29
15+26.29
X
30
14+54.94
X
31
I3+92.94
X
32
I3+32.74
X
33
12+74.87
X
34
11 +52.03
X
35
10+85.62
X
36
10+40.80
X
37
10+13.73
X
67
15+21.29
X
68
14+36.29
X
69
13+71.29
X
70
13+06.29
X
71
12+45.02
X
72
11 +76.29
X
.0
0 40 :I 120 1 jo
CONSTRUCTION NOTES
O CONSTRUCT 8" EXTRA STRENGTH VCP SEWER MAIN
1A CONSTRUCT 4" VCP SEWER LATERAL & HOUSE CLEANOUT PER
CITY S1D. PLAN NO. 2005
OCONSTRUCT 48" PRECAST CONCRETE MANHOLE PER CITY S1D.
PLAN NO. 2001
CITY OF FONTANA, CALIFORNIA
ON -SITE SEWER IMPROVEMENT PLAN
m DESIGNED BY.•
k JS
DRAWN BY
PB
CHECKED BY.• I APPROVED BY
AF
TRACT NO. 20214 3
ROYAL OAKS WAY
CITY ENGINEER
ATE 8/1 /2019
RCE 51152
SCALE:
AS NOTED
DA TE:
JUL Y 2019
DRA WING NO: 5
5809 5