HomeMy WebLinkAbout5759-1SEWER IMPROVEMENT PLANS
GENERAL NOTES
1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND
THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOKI. ALL REFERENCE SPECIFICATIONS AND STANDARDS
SHALL DE THE LATEST EDITIONN UNLESS OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CANNOT BE RESOLVED BY REFERENCE TO PRECEDENCE
PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4, CONSTRCTION PERMITS MALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION
PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START
OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS, CALL (909) 350-7610.
5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA
MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTfRACTO! TO MAINTAIN BARRRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT
ALL TIMES.
7. THE CONTRACTOR SHALL DETAIN A PERMIT TO FORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM
THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
8. THE WALLS AND FACES OF ALL EXCAVATION GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE
GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF
CALIFORNIA, TRENCHES LESS THEN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT.
9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE.
10. THE LOCATIONS OF UTILITIES SHOWN HERE HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE
PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600
TWO WORKING DAYS BEFORE EXCAVATION.
11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO. GAS, TELEPHONE,
ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD
CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES.
12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANTS OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION.
CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS.
13. STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED.
14. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO
THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL
STAKING DURING CONSTRUCTION.
15. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCHMARKS WITHOUT PRIOR NOTIFICATION TO
THE CITY ENGINEER.
16. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH NARKS, SHALL BE
DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF
THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES
TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT.
17. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE
MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES.
18. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF OUST CONTROL, INCLUDING ADEQUATE WATERING. AT ALL TIMES.
19. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT, OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE
PROPERTY ADJACENT TO THE RIGHT OF WAY DURRING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL.
20. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
21. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQU]FEO DENSITY SHALL REQUIRE
RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED.
22. CAFE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE
SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
23. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE.
24. IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL CLEANOUT AT THE PHASE BOUNDARY,
NOT MORE THAN 150 FEET FROM THE DOWNSTREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT.
25. SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE VITRIFIED CLAY PIPE (V.C.P.) EXTRA STRENGTH
CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION C700 FOR VCP.
26. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER.
27. SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL DE USED AT MANHOLE WALLS TO ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT.
28. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS.
CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS.
29. ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER.
30. TERMINATE ALL 4' HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12" BELOW THE GROUND SURFACE. WHEN PUBLIC UTILITY
EASEMENT EXIST NEXT TO THE STREET RIGHT OF WAY, THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS MEASURED FROM
THE UTILITY EASEMENT.
31. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF CURB AT THE LOCATION OF THE SEWER LATERAL.
32. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER
AND ALL AFFECTED AGENCIES IMMEDIATELY.
33. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED.
34. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED. TESTED AND APPROVED PRIOR TO PAVING OF STREETS.
35. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT.
36. ALL MANHOLES, CLEANDUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON
COMPLETION OF PAVING.
37. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL
DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
3B. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS
TO THE CITY ENGINEER.
SEWER LATERAL SCHEDULE
LOT N0,
DESIGN STA.
AS -BUILT STA.
BACKFLOW VALVE
1
1+56.45
NO
2
2+45.45
NO
3
3+03.43
NO
4
3+09.72
NO
5
3+09.72
NO
6
3+09.72
NO
7
2+73.57
NO
8
2+20.55
NO
9
1+39.57
NO
0 . LJ .ENGINEERING AND ASSOCIATES
LAND PLANNING AND CIVIL ENGINEERING
242 E. AIRPORT DRIVE, STE. 212 - SAN BERNARDINO, CA 92408
PHONE (909) 215-3451 EMAIL: suresh@sdengineering.net
SURESH DODDIAH R.C.E. 36361
Z
, zoll
DATE
NORTH
R/W
30'
30'
SOUTH
R/W
1 I I I
I 29 2z '
r -a
11
B" SEWERI V8" WATER
TYPICAL SECTION
LONDON LANE
N.T.S.
FOR
TRACT 20176
Jr1 Cr< F3UI D< F J-\Rl<
z CC 2
PE-59.4
U PE-589 PE=59.0 =
PAR. 2X 00 95 8 5 3 7 N 6
Lu $ 3 3 ^. PE-59.6
� � rn
T,cu
�+ N J
E (V AA A5 9?00S.
34.
moo.
�r1T1. N.89'57'39'E. m � 212.84' N90-3711
l _ _
LONDON LAI qE 1 N
Lo
7 > Q
w < v 9
a ma
51 23 +J3
�(1 DE=58.7 PE=59.1 5 3 PE=59.3
25 5' 5
!8' 18' P U.E.
�ro I
IU I-
M II I -
L�
r IRS r ASS_Ej\A_E3 L Y OF G JJ
CHURCAl
INDEX MAP
SCALE- 1"=50' fN
PE-59.7
PE=59.8
UTILITY NOTIFICATIONS
CITY OF FONTANA
PACIFIC BELL CO.
6353 SIERRA AVENUE
ATTN: VIRGINIA BECKER
FONTANA, CA 92335
3939 E. CORONADO STREET
(909) 350-6632
ANAHEIM. CA 92807
(714) 666-5467
SOUTHERN CALIFORNIA GAS COMPANY
ATTN: DENNIS FREEMAN
UNDERGROUND SERVICE ALERT
19BI W. LUGONIA AVE.
(800) 227-2600
REDLANDS. CA. 92374
(909) 3CIES: 7
COMCAST (CABLE TV)
EMERGENCIES: (BOON 427-2200
ATTN; JACK HAYES
1205 DUPONT AVE.
SOUTHERN CALIFORNIA EDISON COMPANY
ONTARIO. CA 91761
(909) 390-473B
300 N. PEPPER STREET
RIALTO, CA 92376
GENERAL TELEPHONE CO.
(909) 820-5598 -- UNDERGROUND
ATTN: STEVE HOCK
(909) 875-5100 - TRANSMISSION
1400 E. PHIL-LIPS BLVD.
(213) 637-IM - PIPELINES
ONTARIO, CA 91766
(800) 422-4133
SAN GABRIEL VALLEY WATER COMPANY
ATTN: MR. ALAN W. FROST
15%6 ARROW ROUTE
-
FONTANA, CA 92235
(909) 201-7361
t
to
-�/
ciq
LEGEND
cu
0 COL
8" EXTRA STRENGTH
VCP
j 1l
p MH
L T
SEWER LATERAL W/WYE
U L11
NOTE:
$
STATIONING SHOWN ON PLAN REFERS
TO SEWER MAIN CENTERLINE.
rn
CONSTRUCTION NOTES
QUANTITIES
o-
CONST. 8" EXTRA STRENGTH V.C.P. SEWER LINE
209 LF
02 --
CONST. STANDARD CAST -IN PLACE 48- MANHOLE PER CITY STO NO. 2001
1 EA
So--
CONST. 4" SEWER LATERAL/HOUSE CLEAN -OUT PER CITY STD NO. 2005
345 LF
Q4 -
TRENCH AND RE -SURFACE 3.5' STRIP ON WANTRY AVENUE
82 SF
PER CITY OF FONTANA STO NO, 1008
5O-
INSTALL SEWER CLEANOUT BOX PER CITY STD NO. 2006
9 EA
o--
REMODEL EXISTING MANHOLE
1 EA
REV. REVISION DSCRIPTION DATE ENW. CITY DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT
QRpFESS/0� ZiaYOU
COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL
Dd�,SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS
N0. 363TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND
EXP. 6-30-20 n STANDARDS IN EFFECT.
CIVIL .y
9� OF C P� �r TOLL FREE A PUBLIC SERVICE BY �-227-2�
UNDERGROUND SERVICE ALERT
BENCHMARK CITY BM #591
BEING A BRASS DISC SET IN THE TOP OF CURB
AT THE NORTHEAST CORNER OF OLIVE STREET
AND FONTLEE LANE.
ELEV. = 1185.01
BASIS OF BEARINGS:
BASIS OF BEARINGS WAS TAKEN FROM THE CENTERLINE OF SAN BERNARDINO
AVENUE SHOWN AS N.89'5745"E. PER PARCEL MAP 19238, RECORDED IN
P.M.B. 241, PAGES 26-27, RECORDS OF SAN BERNARDINO COUNTY, CALIFORNIA.
PRIVATE ENGINEER'S NOTICE
TO CONTRACTOR:
THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR LIABLE
FOR. UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS. ALL CHANGES TO THE
PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE
PLANS.
AJWAA CALIFORNIA LLC
ATTN: MR. SHAREEF AWAD
998 S. TEAKWOOD AVENUE
BLOOMINGTON, CA 92316
PH. (909) 519-1355
SWEET INDEX
INDEX SHEET
SEWER PLAN & PROFILE - LONDON LANE
SHEET 1
SHEET 2
w
w
w
>
z
w
i
FOOTHILL a
a
SOLLEVARD
ARROW
BOULEVARD
MERRILL
AVENUE
SITE
a
SAN LINO
AVENUE
VALLEY
BIXLEVARD
SAN BffdJAMIMW FREEWAY
to
®�
DESIGNED B'
CHECKEDBr
so
VICINITY MAP N
NTS
CITY OF FONTANA. CALIFORNIA
SEWER IMPROVEMENT PLANS
TRACT 20176
TITLE, ShlEET
AS SHOWN
5759