Loading...
HomeMy WebLinkAbout5781-8PLAN VI� ! I +s r; w. TYP. CONCRETE TO REST AGAINST UNDISTURBED SOIL ELEVATION J� TYP. CONCRETE THRUST BLOCKS NOTE: THRUST BLOCKS SHALL BE INSTALLED IN ACCORDANCE WITH PIPE MANUFACTURER'S RECOMMENDATION FOR SIZE OF PIPING REQUIRED. UTILIZED IN ALL (2 1/2" AND LARGER MAINLINE PIPE) #3 REBAR TO BE PLACED AROUND PIPE INTO THRUST BLOCK TYP. No.51t52 " CITY ENGINEER DATE RICARDO SANDOVAL EXP.9130105 �- REVIEWED BY: Tlmot 3natpdt cmL ��F F 01 ret lfa) DATE OF LAST REVISION: 1-28-00-00 WEILAND DESIGN GROUP, INC. LANDSCAPE ARCHITECTURE + PLANNING + CONSTRUCTION MANAGEMENT 28924 OLD TOWN FRONT STREET, SUITE 202 TEMECULA, CA 92590 P (844) WEILAND, XT 701 F (619) 675-3426 EMAIL- KLONIGRO@W-D-G.COM CORPORATE OFFICE 291 SIERRA WAVE SWALL MEADOWS, CA 93514 CITY OF FONTANA THRUST BLOCK ASSEMBLY STD. PLAN NO. 5020 OD A-:-, e DIAL ❑RE BEFDAYS BEFORE YOU DIG YOU DIG TOLL FREE 1-800-227-26C A PUBLIC SERVICE BY UNDERGROUND SERVICE ALER1 SHT 1 OF 'I REV. INSTALL A 9" ROUND PLASTIC BOX WITH LOCKING LID SPLICE BLOCK NOTE: TER PROOF CONNECTION MIN. 24" ABOVE GRADE i—FINISH GRADE CONTROL WIRE 2" x 4" RWD BLOCK 1 CU. FT, PEA GRAVEL REMOTE CONTROL BOX MAY BE USED IN UEU OF SPLICE BOX. No. 51152 EXP. 91 OW ,, CIVIL REVISION DESCRIP11ON MAIN SUPPLY, LATERAL AND WIRING 18 ° 4 LATERAL WIRING ' „�� MAINLINE r♦ "1 y^. nF If!: TAPE AND BUNDLE WIRING AT 10' O.C. MAXIMUM TO MAINLAINE. PROVIDE A 20" LOOP OF WIRE IN ALL CHANGES OF DIRECTION GREATER THAN 30 DEGREES REMOVE TIES AFTER ALL CONNETIONS HAVE BEEN MADE PLAN VIEW NOTE: DO NOT INSTALL 120 VOLTAGE OR HIGHER WIRE IN THE SAME TRENCH AS THE IRRIGATION CONTROL WIRING PROVE Y• CITY OF FONTANA SPLICE BOX 00 QCOFESS/pyq� A ROVED BY: �� CITY OF FONTANA CITY ENGINEER DATE ASSEMBLY No.51152 CITY ENGINEER DATE PIPING AND WIRING RICARDO SANDOVAL RICARDO SANDOVAL * e EXP.9130105 T REVIEWED BY: imnth,,lostedt REVIEWED BY: Tlmot Rostedt DATE OF LAST REVISION: 1-28-00 STD. PLAN NO. 5017 SHT OF I sl cm1. It. OF OAt\F DATE OF LAST REVISION: 1-28-00 STD, PLAN NO. 5016 SHT 1 OF SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH DATE ENGR. CITY DATE STANDARDS IN EFFECT. 0 FlilkISHED GRADE 6" MIN FROM .O _ _ .. .. .. .. • Ii,I • �L:IIF�rri`rlr2IRIA�:rr��tl:1f 11a1'=`. i311�11=16rr%err%err%�r�rl=lf JIr-1: —LATERAL LINE 6�i.ly��Irl�rr'ti�r'�' 1 III PRESSURE SUPPLY LINE • R • LL WIRES LT-lIIil FINE GRANULAR MATERIAL WILL BE PLACED ON ALL LINES, NO LARGER THAN 1/2" INCH IN SIZE. THIS WILL BE PERMITTED IN THE INITIAL BACKFILL MEASURED 6" FROM THE TOP OF PIPE. THE REMAINDER OF TRENCH CAN BE FILL WITH ROCK SCREENED 2" MINUS, ALL BACK FILL IS TO BE SATURATED AND COMPACTED TO 90% INSTALL ALL PVC PIPE WITH LABEL UP. SNAKE ALL PIPE IN TRENCH. BUNDLE AND TAPE ALL CONTROL WIRES AT 10' O.C. TO PRESSURE SUPPLY LINE AND PROVIDE A SERVICE LOOP AT ALL 90 DEGREE CHANGES IN DIRECTION. PRESSURE MAIN 2" AND LARGER SHALL BE P.V.C. CLASS 315 SMALLER THAN 2" SHALL BE P.V.C. SCHEDULE 40. CONTRACTOR SHALL PROVIDE SLEEVES OR CONDUIT LINES WHEN MAINLINE INSTALLATION IS UNDER ASPHALT OR CONCRETE. CONTRACTOR SHALL PROVIDE 24" INCHES OF COVER OVER PIPE SERVING A DRINKING FOUNTAIN OR PRESSURE MAINLINE 3" AND LARGER. ZROfESs)pyq` AP ov BY: CITY OF FONTANA rRpO SAypo Fyn G�� F ,l p No.51152 CITY ENGINEER DATE TRENCHING DETAIL RICARDO SANDOVAL EXP.9130105 CIVILREVIEWED BY: —limoth; Rostedt or cAIFF DATE OF LAST REVISION: 1-28-00 STD. PLAN NO. 5015 SHT 1 OF Prepared Under The Supervision Of : CITY OF FONTANA, CALIFORNIA CFD STREETSCAPE LANDSCAPE PLANS DRAWN BY: EL PASEO TR20082 SCALE: K7L/13G/1',� As Noted DE -SIGNED BY: KB HOME SOUTHERN CALIFORNIA DATE: 0�1001fA IRRI ATION DETAILS 01/09/2019 Date 01/09/19 CHECKED BY: APPROVED DRAWING NO.: KIM T. LONIGRO L.L.A. 5508 06 DATE: 's"' LI-06IT;-FICLC R.C.. 819 ea