Loading...
HomeMy WebLinkAbout5781-6NOTE: THESE SUGGESTED RUN TIMES ARE FOR REFERENCE ONLY. ACTUAL RUN TIMES MAY DIFFER DUE TO VARYING SITE CONDITIONS. CONTRACTOR SHALL ADJUST RUN TIMES AS REQUIRED TO PROVIDE APPROPRIATE WATER FOR EACH VALVE CIRCUIT. Controller, A IRRIGATt 1d Covers: 0,81 6 2 9 1.23 Model # MPS-A16-1OK IRRIGATION CONTROL I BOARD METER I I IJ I I I I iJ I I I EXACT LOCATION OF CONTROLLER SHALL BE AGREED UPON BY EDISON, CITY LANDSCAPE INSPECTOR AND CONTRACTOR PRIOR TO ANY TRENCHING OR WIRE PLACEMENT GENERAL NOTES PROVIDE IDGA METER AND 5OA/2P MAIN C/O WHERE INDICATED ON DRAWINGS PROVIDE PANELBOARD WHERE INDICATED ON DRAWINGS. PROVIDE IRRIGATION CONTROLLER CABINET WHERE INDICATED ON DRAWINGS. TERMINATE AT EXISION HANDHOLE. PER S.C.E. COMPANY RED. VERIFY EXACT LOCATION AND TERMINATION RED. WITH S.C.E. CO. PRIOR TO TRENCHING CONDUIT AND CONDUCTOR SIZES ARE BASED ON RONMETALLEC CONDUIT AND COPPER CONDUCTORS WITH TYPE-THHN/THWN" INSULATION. METER FACES STREET ELLS 'CONDUIT FOR CONTROLLER WIRES END VIEW STRONG BOX MODEL NO. SB- 24SS/120V CITY OF FONTANA No.51152 CITY ENGINEER DATE IRRIGATION CONTROLLER RICARDO SANDOVAL cIWL REVIEWED BY: �4 OF CAL\FORS\@ DATE OF LAST REVISION: 6-22-15 STD. PLAN N0. 5005 SHT 'I OF 3 El Paseo'Street Scape ! JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC Total; Irrigation Schedule ETo/Mo 1 19 2:6 3.9 4.7 5.8 6.9 7.9 7.4 5.9 4.1 2.6 1.9 55.6 POC / Controller A ET6/Day 1 0.06 0.09 0.13 0.16 019 0.23 0.25 0.24 0.20 0.13 1 0.09 0.06 k _ I , i I -- -_ r I j - Type A1Cc Pr Rate IE _ _ Drip 0.2 0.9 0.81 1.9 2.6 3:8 4:6 5.7 6.9 7.9 7.4 5.9 4.1 2.6 1.9 Min/Day 5 City. of Valves Total Run Times 10 13 19 23 29 35 40 37 30 21 13 10 Total Min/Day Bubblers 0.4 0.63 0.81 2.9 4A 5.9 7.4 8.8 10.8 12.0 112 9.2 6.2 4.1 2.9 Min/Day 2 Qty. of Valves Total Run Times 6 9 12 15 18 22 24 22 18 12 8 6 Total Min/Day L Total Valves:: 7 TOTAL RUN TIMES (HRS):; 0.3 0.4 0.5 0.6 0.8 0.9 1.1 1.0 0.8 0.5 0.4 0.3 I JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC EI Paseo Street SGape j JAN fEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC Total: [irrigation Schedule ETo/Mo 1.9 2:6 3.9 4.7 5.8 6.9 7.9 7.4 1 5.9 4.1 2.6 1.9 55.6 POC / Controller B ETo/Day 0.06 0.09 0:13 0.16 0 19 0L23 025 0:24 020 0.13 0;09 0.06 I I -- - - I Type AKc Pr Rate IE Dri;p 0 2 1 0-9 0,81 1.9 2.6 3.8 4-6 5.7 6.9 7.9 7.4 5.9 4.1 2.6 1.9 Min/Day 6 City. of Valves Total Run Times 11 16 23 28 34 41 47 44 35 25 16 11 Total Min/Day Bubblers O;4 0.63 0.81 2.9 4.4 5.9 7.4 8.8 10.8 12-0 11.2 9.2 6.2 4.1 2.9 Min/Day 3 City. of Valves Total Run Times 9 13 18 22 26 32 36 34 28 19 12 9 Total Min/Day i Total Valves:; 9 q TOTAL RUN TIMES (HRS).i 0.3 0.5 0.7 0.8 1.0 1.2 1.4 1.3 1.1 0.7 0.5 0.3 JAN fEB MAR APR MAY JUN JUL AUG V SEP OCT NOV DEC WEILAND DESIGN GROUP, INC. LANDSCAPE ARCHITECTURE + PLANNING + CONSTRUCTION MANAGEMENT 28924 OLD TOWN FRONT STREET, SUITE 202 TEMECULA, CA 92590 P (844) WEILAND, XT 701 F (619) 675-3426 EMAIL - KLONIGRO@W-D-G.COM CORPORATE OFFICE 291 SIERRA WAVE SWALL MEADOWS, CA 93514 D �,E, EDT A�YV , 0 DIAL TWD WORKING BEFORE DAYOUBDI�RE Y❑U DIG TOLL FREE 1-800-227-26C A PUBLIC SERVICE BY UNDERGROUND SERVICE ALER' NOTE: ALL POWER WIRES, GROUND WIRES ETC. SHALL BE SEPARATELY SLEEVED AND SWEPT THROUGH ENCLOSED PAD WITH SCH 40 RIGID CONDUIT ALL SLEEVING SHALL BE A MINIMUM OF 18" BELOW FINISHED GRADE. ALL SLEEVING IS A GRAPHIC REPRESENTATION IRRIG. OF A TYP. INSTALLATION. CONT. SIZE OF CONC. SLAB - 8" THICK W/#4 REBARS AT 12" O.C. TYP 50 A 2P 07 FINISHED GRADE GROUND FOR ELECTRICAL 120/240 D 3W 12 CIR PANEL 3/4-G. 1#6 8" DIA. X 12' D. BOTTOMLESS GROUND WELL WITH PARKWAY COVER, FILL WITH PEA GRAVEL 5/8-DIA X 10' DRIVEN GROUND ROD PER ARTICLE 250-81 OF 1990 NEC CITY OF FONTANA JNo.511552CITY ENGINEER DATE IRRIGATION CONTROLLER RICARDO SANDOVAL REVIEWED BY: S OF CAL1F1 DATE OF LAST REVISION: 6-22-15 STD. PLAN NO. 5005 SHT Z OF 3 CONTROLLER "A" City of Fontana, CA Department of Engineering WATER EFFICIENT LANDSCAPE WORKSHEET Project Reference Evapotranspiration (Eta) 55.6 Hydrozone # / Planting Description Plant Factor (PF) Irrigation Method Irrigation Efficiency (IE) ETAF (PF/IE) Landscape Area (Sq. Ft.) ETAF x Area Estimated Total Water Use (ETWU) Regular Landscape Areas 1 0.3 Drip 1 0.81 10.37037037 5,620,00 2081.481481 71,752.83 2 0.4 Bubbler 1 0.81 10.49382716 864.00 426.6666667 14,708.05 3 0.5 Drip 0.81 10.617283951 933.00 575.9259259 19'B53.32 Totals 7,417.00 3,084.07L0614.20 ETWU Total14.20 MAWA65.47 Notes: 1. Irrigation Efficiency - 0.75 Spray Head, 0.81 Drip 2. ETWU = Annual Gallons Required = (Eto*0.62*ETAF*Area) 3. MAWA = Annual Gallons Allowed = (Eta) (0.62) [(ETAF*LA)+((1-ETAF)*SLA)] ETAF Calculations Regular Landscape Areas Total ETAF x Area 3,084.07 Total Area 7,417.00 Average ETAF 1 0.42 All Landscape Areas Total ETAF x Area 3,084.07 Total Area 7,417.00 Average ETAF 0.42 Signed: Average ETAF for Regular Landscape Areas must be 0.55 or below for residential areas, and 0.45 or below for non-residential areas. Date 8/16/2018 SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE REV, PLANS TO BRING THEM INTO CONFORMANCE WITH REVISION DESCRIPTION DATE ENGR. CITY DATE STANDARDS IN EFFECT. City of Fontana Irrigation Controller Standard For Cominunities Facilities Districts (CFD) Toro Sentinel controller installed in an approved stainless steel Edison meter box enclosure. Contact Green Product Sales with the following numbers for the City of Fontana meter/controller. Fontana part # for a 48 station controller E SB 48-U2-MPEA l 610K-OB 1- VRA Required items to be included with each controller installed: I . W 12-XB Toro Sentinel 12 station wireless output board, level 3 surge protection with XB-Spread Spectrum Radio 2. TK-3170 Kenwood hand held remote w/ charger set to City of Fontana frequency programming 3. After controller installation contact Green Product Sales to schedule inspection for certification Contacts: Imperial Sprinkler Supply Luis Muriel Phone: (714) 696-7535 ��QpOFESS/Oyq/ /AP 1VE Y: CITY OF FONTANA �wQQ�aR40 Sgyoo`lFy� a a No. 51152 ITY ENGINEER C DATE IRRIGATION CONTROLLER RICARDO SANDOVAL * s CIVIL * REVIEWED BY: K� lgrF OF CAL1FDATE OF LAST REVISION: 6-22-15 STD. PLAN N0. 5005 SHT 3 OF 3 CONTROLLER "B" City of Fontana, CA Department of Engineering WATER EFFICIENT LANDSCAPE WORKSHEET Project Reference Evapotranspiration (Eta) 55.6 Hydrozone # / Planting Description Plant Factor (PF) Irrigation Method Irrigation Efficiency (IE) ETAF (PF/IE) Landscape Area (Sq. Ft.) ETAF x Area Estimated Total Water Use (ETWU) Regular Landscape Areas 1 0.2 Drip 0.81 1 0.24691358 1 8,6601.00 12138.271605 73,710.50 2 0.4 Bubblers 0.81 10.49382716 1 684.00 1337.7777778 11,643.88 Totals 1 9,344.00 1 2,476,05 85,354.37 ETWU Total 85,354.37 MAWA 144,947.87 Notes: 1. Irrigation Efficiency - 0.75 Spray Head, 0.81 Drip 2. ETWU = Annual Gallons Required = (Eto*0.62*ETAF*Area) 3. MAWA = Annual Gallons Allowed = (Eta) (0.62) [(ETAF*LA)+((1-ETAF)*SLA)] ETAF Calculations Regular Landscape Areas Total ETAF x Area 1%6.05 Total Area 9344.00 Average ETAF 0.26 All Landscape Areas Total ETAF x Area 2,476.05 Total Area 9,344.00 Average ETAF 1 0.26 Signed: Average ETAF for Regular Landscape Areas must be 0.55 or below for residential areas, and 0.45 or below for non-residential areas. Date: 8/16/2018 Prepared Under The Supervision Of : CITY 01 FONTANA, CALIFORNIA CFD STREETSCAPE LANDSCAPE PLANS �� L DRAWN BY: EL PASEO TR20082 SCALE: DESIGNED BY: KB HOME SOUTHERN CALIFORNIA As Noted DATE: KV001fA IRRIGATION DETAILS 01/09/2019 Date : 01/09/19 CHECKED BY: APPROVE DRAWING NO.: 6 KIM T. LONIGRO L.L.A. 5508 G DATE M 6 LI-04