HomeMy WebLinkAbout5781-6NOTE:
THESE SUGGESTED RUN TIMES ARE FOR REFERENCE
ONLY. ACTUAL RUN TIMES MAY DIFFER DUE TO
VARYING SITE CONDITIONS. CONTRACTOR SHALL
ADJUST RUN TIMES AS REQUIRED TO PROVIDE
APPROPRIATE WATER FOR EACH VALVE CIRCUIT.
Controller, A IRRIGATt
1d Covers:
0,81
6
2
9
1.23
Model # MPS-A16-1OK
IRRIGATION CONTROL I
BOARD
METER I I IJ
I I I
I iJ
I
I
I
EXACT LOCATION OF CONTROLLER SHALL BE AGREED
UPON BY EDISON, CITY LANDSCAPE INSPECTOR AND
CONTRACTOR PRIOR TO ANY TRENCHING OR
WIRE PLACEMENT
GENERAL NOTES
PROVIDE IDGA METER AND 5OA/2P MAIN C/O WHERE INDICATED
ON DRAWINGS
PROVIDE PANELBOARD WHERE INDICATED ON DRAWINGS.
PROVIDE IRRIGATION CONTROLLER CABINET WHERE INDICATED
ON DRAWINGS.
TERMINATE AT EXISION HANDHOLE. PER S.C.E. COMPANY RED.
VERIFY EXACT LOCATION AND TERMINATION RED. WITH S.C.E. CO.
PRIOR TO TRENCHING
CONDUIT AND CONDUCTOR SIZES ARE BASED ON RONMETALLEC CONDUIT
AND COPPER CONDUCTORS WITH TYPE-THHN/THWN" INSULATION.
METER FACES
STREET
ELLS 'CONDUIT FOR
CONTROLLER
WIRES
END VIEW
STRONG BOX
MODEL NO. SB- 24SS/120V
CITY OF FONTANA
No.51152 CITY ENGINEER DATE IRRIGATION CONTROLLER
RICARDO SANDOVAL
cIWL REVIEWED BY: �4
OF CAL\FORS\@ DATE OF LAST REVISION: 6-22-15
STD. PLAN N0. 5005 SHT 'I OF 3
El Paseo'Street Scape !
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
DEC
Total;
Irrigation Schedule
ETo/Mo
1 19
2:6
3.9
4.7
5.8
6.9
7.9
7.4
5.9
4.1
2.6
1.9
55.6
POC / Controller A
ET6/Day
1 0.06
0.09
0.13
0.16
019
0.23
0.25
0.24
0.20
0.13
1 0.09
0.06
k
_
I
,
i
I
--
-_
r
I
j
-
Type A1Cc Pr Rate
IE
_ _
Drip
0.2 0.9
0.81
1.9
2.6
3:8
4:6
5.7
6.9
7.9
7.4
5.9
4.1
2.6
1.9
Min/Day
5 City. of Valves
Total Run Times
10
13
19
23
29
35
40
37
30
21
13
10
Total Min/Day
Bubblers
0.4 0.63
0.81
2.9
4A
5.9
7.4
8.8
10.8
12.0
112
9.2
6.2
4.1
2.9
Min/Day
2 Qty. of Valves
Total Run Times
6
9
12
15
18
22
24
22
18
12
8
6
Total Min/Day
L
Total Valves:: 7 TOTAL RUN TIMES (HRS):;
0.3
0.4
0.5
0.6
0.8
0.9
1.1
1.0
0.8
0.5
0.4
0.3
I
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
DEC
EI Paseo Street SGape j
JAN
fEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
DEC
Total:
[irrigation Schedule
ETo/Mo
1.9
2:6
3.9
4.7
5.8
6.9
7.9
7.4 1
5.9
4.1
2.6
1.9
55.6
POC / Controller B
ETo/Day
0.06
0.09
0:13
0.16
0 19
0L23
025
0:24
020
0.13
0;09
0.06
I
I
--
- -
I
Type AKc Pr Rate
IE
Dri;p
0 2 1 0-9
0,81
1.9
2.6
3.8
4-6
5.7
6.9
7.9
7.4
5.9
4.1
2.6
1.9
Min/Day
6 City. of Valves
Total Run Times
11
16
23
28
34
41
47
44
35
25
16
11
Total Min/Day
Bubblers
O;4 0.63
0.81
2.9
4.4
5.9
7.4
8.8
10.8
12-0
11.2
9.2
6.2
4.1
2.9
Min/Day
3 City. of Valves
Total Run Times
9
13
18
22
26
32
36
34
28
19
12
9
Total Min/Day
i
Total Valves:; 9 q TOTAL RUN TIMES (HRS).i
0.3
0.5
0.7
0.8
1.0
1.2
1.4
1.3
1.1
0.7
0.5
0.3
JAN
fEB
MAR
APR
MAY
JUN
JUL
AUG
V SEP
OCT
NOV
DEC
WEILAND DESIGN GROUP, INC.
LANDSCAPE ARCHITECTURE + PLANNING + CONSTRUCTION MANAGEMENT
28924 OLD TOWN FRONT STREET, SUITE 202 TEMECULA, CA 92590
P (844) WEILAND, XT 701 F (619) 675-3426
EMAIL - KLONIGRO@W-D-G.COM
CORPORATE OFFICE
291 SIERRA WAVE SWALL MEADOWS, CA 93514
D �,E, EDT
A�YV ,
0
DIAL TWD WORKING
BEFORE DAYOUBDI�RE
Y❑U DIG
TOLL FREE 1-800-227-26C
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALER'
NOTE:
ALL POWER WIRES, GROUND WIRES ETC. SHALL BE
SEPARATELY SLEEVED AND SWEPT THROUGH
ENCLOSED PAD WITH SCH 40 RIGID CONDUIT
ALL SLEEVING SHALL BE A MINIMUM OF 18" BELOW
FINISHED GRADE. ALL SLEEVING IS A GRAPHIC REPRESENTATION
IRRIG. OF A TYP. INSTALLATION.
CONT.
SIZE OF CONC. SLAB - 8" THICK
W/#4 REBARS AT 12" O.C. TYP
50 A
2P
07
FINISHED GRADE
GROUND FOR ELECTRICAL
120/240
D 3W
12 CIR
PANEL
3/4-G. 1#6
8" DIA. X 12' D.
BOTTOMLESS GROUND WELL
WITH PARKWAY COVER,
FILL WITH PEA GRAVEL
5/8-DIA X 10' DRIVEN GROUND
ROD PER ARTICLE 250-81
OF 1990 NEC
CITY OF FONTANA
JNo.511552CITY ENGINEER DATE IRRIGATION CONTROLLER
RICARDO SANDOVAL
REVIEWED BY: S
OF CAL1F1 DATE OF LAST REVISION: 6-22-15 STD. PLAN NO. 5005 SHT Z OF 3
CONTROLLER "A"
City of Fontana, CA
Department of Engineering
WATER EFFICIENT LANDSCAPE WORKSHEET
Project Reference Evapotranspiration (Eta) 55.6
Hydrozone
# / Planting
Description
Plant Factor
(PF)
Irrigation
Method
Irrigation
Efficiency
(IE)
ETAF
(PF/IE)
Landscape
Area (Sq.
Ft.)
ETAF x
Area
Estimated
Total Water
Use (ETWU)
Regular Landscape Areas
1
0.3
Drip
1 0.81
10.37037037
5,620,00
2081.481481
71,752.83
2
0.4
Bubbler
1 0.81
10.49382716
864.00
426.6666667
14,708.05
3
0.5
Drip
0.81
10.617283951
933.00
575.9259259
19'B53.32
Totals
7,417.00
3,084.07L0614.20
ETWU Total14.20
MAWA65.47
Notes:
1. Irrigation Efficiency - 0.75 Spray Head, 0.81 Drip
2. ETWU = Annual Gallons Required = (Eto*0.62*ETAF*Area)
3. MAWA = Annual Gallons Allowed = (Eta) (0.62) [(ETAF*LA)+((1-ETAF)*SLA)]
ETAF Calculations
Regular Landscape Areas
Total ETAF x Area
3,084.07
Total Area
7,417.00
Average ETAF
1 0.42
All Landscape Areas
Total ETAF x Area
3,084.07
Total Area
7,417.00
Average ETAF
0.42
Signed:
Average ETAF for Regular Landscape Areas must be
0.55 or below for residential areas, and 0.45 or below for
non-residential areas.
Date
8/16/2018
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
REV, PLANS TO BRING THEM INTO CONFORMANCE WITH
REVISION DESCRIPTION DATE ENGR. CITY DATE STANDARDS IN EFFECT.
City of Fontana
Irrigation Controller Standard
For Cominunities Facilities Districts
(CFD)
Toro Sentinel controller installed in an approved stainless steel Edison meter box enclosure.
Contact Green Product Sales with the following numbers for the City of Fontana
meter/controller.
Fontana part # for a 48 station controller
E SB 48-U2-MPEA l 610K-OB 1- VRA
Required items to be included with each controller installed:
I . W 12-XB Toro Sentinel 12 station wireless output board, level 3 surge protection with
XB-Spread Spectrum Radio
2. TK-3170 Kenwood hand held remote w/ charger set to City of Fontana frequency
programming
3. After controller installation contact Green Product Sales to schedule inspection for
certification
Contacts:
Imperial Sprinkler Supply
Luis Muriel
Phone: (714) 696-7535
��QpOFESS/Oyq/ /AP 1VE Y: CITY OF FONTANA
�wQQ�aR40 Sgyoo`lFy� a
a No. 51152 ITY ENGINEER C DATE IRRIGATION CONTROLLER
RICARDO SANDOVAL
* s CIVIL * REVIEWED BY: K�
lgrF OF CAL1FDATE OF LAST REVISION: 6-22-15 STD. PLAN N0. 5005 SHT 3 OF 3
CONTROLLER "B"
City of Fontana, CA
Department of Engineering
WATER EFFICIENT LANDSCAPE WORKSHEET
Project Reference Evapotranspiration (Eta) 55.6
Hydrozone
# / Planting
Description
Plant Factor
(PF)
Irrigation
Method
Irrigation
Efficiency
(IE)
ETAF
(PF/IE)
Landscape
Area (Sq.
Ft.)
ETAF x
Area
Estimated
Total Water
Use (ETWU)
Regular Landscape Areas
1
0.2
Drip
0.81
1 0.24691358
1 8,6601.00
12138.271605
73,710.50
2
0.4
Bubblers
0.81 10.49382716
1 684.00
1337.7777778
11,643.88
Totals
1 9,344.00
1 2,476,05
85,354.37
ETWU Total
85,354.37
MAWA
144,947.87
Notes:
1. Irrigation Efficiency - 0.75 Spray Head, 0.81 Drip
2. ETWU = Annual Gallons Required = (Eto*0.62*ETAF*Area)
3. MAWA = Annual Gallons Allowed = (Eta) (0.62) [(ETAF*LA)+((1-ETAF)*SLA)]
ETAF Calculations
Regular Landscape Areas
Total ETAF x Area
1%6.05
Total Area
9344.00
Average ETAF
0.26
All Landscape Areas
Total ETAF x Area
2,476.05
Total Area
9,344.00
Average ETAF
1 0.26
Signed:
Average ETAF for Regular Landscape Areas must be
0.55 or below for residential areas, and 0.45 or below for
non-residential areas.
Date: 8/16/2018
Prepared Under The Supervision Of : CITY 01 FONTANA, CALIFORNIA
CFD STREETSCAPE LANDSCAPE PLANS �� L
DRAWN BY: EL PASEO TR20082 SCALE:
DESIGNED BY: KB HOME SOUTHERN CALIFORNIA As Noted
DATE:
KV001fA IRRIGATION DETAILS 01/09/2019
Date : 01/09/19 CHECKED BY: APPROVE DRAWING NO.: 6
KIM T. LONIGRO L.L.A. 5508 G DATE
M 6 LI-04