HomeMy WebLinkAbout5697-19
0
00
0
N
0
0
CL
S ii N0/FS
1 ALL WORK SHALL BE IN ACCORDANCE' WITH THESE PLANS, THE CITY OF
FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD
SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL
REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION
UNLESS OTHERWISE NOTED.
2 WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT
DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE
PROVISIONS IN THE "GREEN BOOK" THE CONTRACTOR SHALL IMMEDIATELY
REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
3 ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE
CITY ENGINEER.
4 CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA
COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE
START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT
LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC
RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
5 THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES,
METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL
OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE
DIRECTED BY THE CITY TRAFFIC ENGINEER.
6 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN
BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL
TIMES.
7 THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR
TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE
CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
8 THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET
IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR
OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION
OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN
FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR
GROUND MOVEMENT.
9 NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF
WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE.
10 THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM
AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND
ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION
TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND
SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE
EXCAVATION.
11 THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY
COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC,
CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER,
RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS.
ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR
TO WORK AROUND THEIR FACILITIES.
12 THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER
MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR
SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE
OPERATION AND WATER REQUIREMENTS.
13 STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE
OTHERWISE NOTED.
14 ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE
ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE
PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE
PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING
DURING CONSTRUCTION.
15 THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS,
MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY
ENGINEER.
16 REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING
SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE
BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY
MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION
SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE
WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE
ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT.
17 THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND
BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED
AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY
VEHICLES.
18 THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF
DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES.
19 THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT
OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT
TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN
APPROVAL.
20 NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF
THE CITY INSPECTOR.
21 A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION.
FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF
THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED.
22 CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES
FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE,
THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODABLE SWALES
ENTERING OR LEAVING IMPROVEMENTS.
23 ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR
AND FINISH TO MATCH EXISTING CONCRETE.
24 . IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR
SHALL PROVIDE A TERMINAL CLEANOUT AT THE PHASE BOUNDARY, NOT MORE
THAN 150 FEET FROM THE DOWNSTREAM MANHOLE, SEE CITY OF FONTANA
STANDARD DETAIL FOR TERMINAL CLEANOUT.
25 SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR
BAND SEAL TYPE VITRIFIED CLAY PIPE (V.C.P.) EXTRA STRENGTH CLASS AND
SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION C700 FOR
V.C.P.
26 NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT
PRIOR APPROVAL OF THE CITY ENGINEER.
27 SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED
AT MANHOLE WALLS TO ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT.
28 PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING
FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY
APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY
CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS.
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
28 PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING
FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY
APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY
CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS.
29 ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE
UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER.
30 TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH
A PLUG 12" BELOW THE GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS
EXIST NEXT TO THE STREET RIGHT OF WAY, THE LATERAL SHALL TERMINATE 3
FEET INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT.
31 THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE
CURB AT THE LOCATION OF THE SEWER LATERAL.
32 IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE
PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER
AND ALL AFFECTED AGENCIES IMMEDIATELY.
33 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING
STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED.
34 ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED
PRIOR TO PAVING OF STREETS.
35 APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT
PAVEMENT PRIOR TO PLACEMENT.
36 ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE
RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION
OF PAVING.
37 UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL
SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO
THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
38 AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE
ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY
ENGINEER.
CITY OF R)NTANAr UTILITY NOTIFICATION LIST
CITY OF FONTANA
AT&T
8353 SIERRA AVE
22311 BROOKHURST ST SUITE 203
FONTANA, CA 92335
HUNTINGTON BEACH, CA 92646
(909) 350-6632
(714) 963-7964
SO. CALIF. GAS COMPANY
SPRINT
1981 W. LUGONIA AVE
2592 DUPONT DR
REDLANDS, CA 92374
IRVINE, CA 92612
(909) 335-7967
(800) 659-9698
EMERGENCIES: (800) 427-2200
TIME WARNER CABLE
SO. CALIF. EDITON COMPANY
1500 AUTO CENTER DR
300 N. PEPPER AVE
ONTARIO, CA 91761
RIALTO, CA 92376
(909) 975-3439
909 820-5598 - UNDERGROUND
SUNESYS, LLC
909 875-5100 - TRANSMISSION
1325 PICO ST 1106
213 637-1233 - PIPELINES
CORONA, CA 92881
909 357-6505 - DISTRIBUTION
(951) 278-0400
FONTANA WATER COMPANY
UNDERGROUND SERVICE ALERT
15966 ARROW BOULEVARD
(800) 422-4133
FONTANA, CA 92335
(909) 822-2201
DEMOPER SOILS ENGINEER
GRAND PACIFIC COMMUNITIES, CORP SOILS SOUTHWEST, INC.
100 N. BARRANCA AVE., SUITE 950 897 VIA LATA, SUITE "N"
WEST COVINA, CA 91791 COLTON, CA 92324
(626) 858-8666 TEL (909) 370-0474
FAX (909) 370-3156
PRIVATE ENGINEERS NOTICE TO CONTRACTOR:
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES AND/OR STRUCTURES
SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS.
THESE LOCATIONS ARE APPROXIMATE AND SHALL BE CONFIRMED BY THE CONTRACTOR,
SO THAT ANY NECESSARY ADJUSTMENT CAN BE MADE IN ALIGNMENT AND/OR GRADE
OF THE PROPOSED IMPROVEMENT. THE CONTRACTOR IS REQUIRED TO TAKE DUE
PRECAUTIONARY MEASURES TO PROTECT ANY UTILITY LINES SHOWN AND ANY OTHER
LINES NOT ON RECORD OR NOT SHOWN ON THESE PLANS.
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED
CONSTRUCTION PRACTICES, HE WILL BE REQUIRED TO ASSUME
SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE
OF CONSTRUCTION OF THE PROJECT, INCLUDING THE SAFETY OF ALL PERSONS AND
PROPERTY. THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND
NOT BE LIMITED TO NORMAL WORKING HOURS. CONSTRUCTION CONTRACTOR FURTHER
AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY
AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF
WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE
OF THE DESIGN PROFESSIONAL..
UNAUTHORIZED CHANGES AND USES:
THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR OR LIABLE
FOR, UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS. ALL CHANGES TO THE
PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS.
CONSTRUCTION STAKING NOTICE
THESE IMPROVEMENT PLANS HAVE BEEN PREPARED WITH THE INTENT THAT THE FIRM OF
ALLARD ENGINEERING INC. WILL BE PERFORMING THE CONSTRUCTION STAKING FOR THE
COMPLETE PROJECT. HOWEVER, IF ANOTHER ENGINEERING AND/01? SURVEYING FIRM
SHOULD BE EMPLOYED TO USE THESE PLANS FOR THE PURPOSE OF CONSTRUCTION
STAKING, NOTICE IS HEREBY GIVEN THAT THE FIRM OF ALLARD ENGINEERING INC. WILL NOT
ASSUME ANY RESPONSIBILITY FOR ERRORS OR OMISSIONS, WHICH COULD HAVE BEEN
AVOIDED, CORRECTED OR MITIGATED IF ALLARD ENGINEERING INC. HAD PERFORMED THE
STAKING WORK.
CITY OF FONTANA
TRACT NO.18981
SEWER IMPROVEMENT PLANS
SHEET INDEX
SHEET 1
TITLE SHEET
SHEET 2
MICHIGAN PLACE & MUIRFIELD LANE
SHEET 3
PENNSYLVANIA AVENUE
SHEET 4.
PITZER STREET
SHEET 5
NOTEE DAME STREET
SHEET 6
GEORGETOWN WAY
SHEET 7
BROWN COURT & TAFT COURT
NO
CONTRACTOR AND SURVEYOR TO VERIFY
SEWER LATERAL LOCATIONS.
FLATTEN SEWER LATERALS TO AVOID
STORM DRAIN CONFLICT.
INDEX MAP
SCALE: 1 "=150'
SEWER MAIN STREET
5'
SUMMIT AVE
FONTMA
a
M
Ir
I nso
•A t'
s ■ • . • • 0 . , s i
CONSTRUCTION NOW.ESTIMATED QUANTITIES
1 CONSTRUCT 8" EXTRA STRENGTH V.C.P. SEWER MAID 4,865 LF
2 CONSTRUCT 48" PRECAST CONCRETE MANHOLE 15 EA
PER CITY STD. DWG. NO. 2001
CONSTRUCT 4' V.C.P. SEWER LATERAL & HOUSE 4,119 LF 3F
CLEANOUT PER CITY STD. DWG. NO 2005
4 CONSTRUCT BACKWATER CHECK VALVE 29 EA
5 REPAIR TRENCH PER CITY STD. 1008 250 LF
6 INSTALL 8" SEWER PLUG 1 EA
7 CONSTRUCT 8" D.I.P. SEWER MAIN 159 LF
8 CONSTRUCT 60" PRECAST CONCRETE MANHOLE 1 EA
PER CITY STD. DWG. NO. 2001
3' MAX SIZE NATIVE
LEGEND
SOIL, COMPACTED 95%
6" MIN.
6" MIN.
SEWER LINE
10" MAX,
10" MAX.
— — — S — — — EXIST. SEWER LINE
g
WATER MAIN 6" MAX SIZE NATIVE �
N
j n:
W
SOIL, COMPACTED 907 mt }
STORM DRAIN LINE
1 MAX. SIZE SELECTED
FUTURE STORM DRAIN LINE
NATIVE BEDDING COMPACTED
TO 907
EXIST. SEWER MANHOLE
SEWER MANHOLE
CN
- -
CENTERLINE
ur
FIRE HYDRANT
CV
6
n a.
CS
z--
STREET LIGHT
-■��
i
DIRECTION OF FLOWpµ
RIGHT OF WAY 8" VCP/DIP
�-
- - --
TYPIC4 BEDDING FOR r VCP
USS THAN 10' DEEP
NTS
I. 6" ► i
4
° PCC CONCRETE
® °
CONCRETE ENOA.SR ENT fOR r VCP
6
WATER z
STORM DRAIN v
50
lk�BOTTOM OF WATER
PIPE O.D. ELEV.
PROPOSED STORM DRAIN
BOTTOM OF STORM DRAI
4" LATERAL ' PIPE ELEV. TOP OF SEWER
LATERAL PIPE ELEV
S=0.0200 - — -
® �-<�i22.5'
ENGR. DATE CITY DATE BASIS OF BEARINGS:SHOULD CONSTRUCTION OF REQUIRED Prepared For: THE BASIS OF BEARINGS WAS TAKEN FROM THE CENTERLINE OF
IMPROVEMENTS NOT COMMENCE WITHIN CITRUS AVENUE AS SHOWN ON TRACT 16540, M.B. 299/13-15.
TWO YEARS OF THE DATE OF APPROVAL BEING:. N00' 16'44"W
SHOWN HEREON AND CARRIED FORTH IN A GRAND PACIFIC COMMUNITIES, CORP 100 N. BARRANCA AVE., SUITE 950 BENCH",
DILIGENT MANNER, THE CITY WEST COVINA, CA ENGINEER MAY 91791 CALTRANS BENCHMARK NO. 8-17 REQUIRE REVISIONS TO THE PLANS TO (626) 858-8666 BRASS CAP IN CONCRETE S.C.E. TOWER LEG. 343' N/0_ HIGHLAND AVENUE, 0.2 MI W/0 SAN SEVAlNE ROAD, IN SOUTH
BRING THEM INTO CON�CE CONCRETE BASE OF S.C.E. TOWER 19.5; 2.65 MI. WEST
CONDITIONS AND STANDARDS IN EFFECT ALONG HIGHLAND AVENUE FROM SIERRA AVENUE
EL=1428.609
DOI
NOT TO SCALE
3" MAX SIZE NATIVE
SOIL, COMPACTED 95%
6" MIN. 6" MIN.
10" MAx. ( o MAX.
6" MAX SIZE NATIVE
SOIL, COMPACTED 907
I" MAX. SIZE SELECTED
NATIVE BEDDING COMPACTED
TO 9070
1/2" CRUSHED
STONE BEDDING,
PER STD SPECS ci
N
FOR PUBLIC WORKS + . _ `a
€ , ��
CONSTRUCTION
TABLE 200-1.2(A) ' _
�'�.,k�# �,``` �
SHOWN BELOW 8" VCP/DIP
TYPICAL BEDDING FOR r VCP
10' OR DEEPER
NIS
Prepared By:
Q�®FEssf®�
ALLARD ENGINEERING
e<<\
Civil Engineering - Land Surveying - Land Planning DRAWN BY:
16866 Seville Avenue ® z HMG/DBW
Fontana, California 92335 ca N®' 3f>052 �
rri DESIGNED BY: DBW/HMG
(909) 356-1815 Fax (909) 365-1795 Exp. 6/30/18
e s� e�'
-C. - 2 . J 6, -y�F ®C t V 1 L\�a�� CHECKED BY:
-Ra and J. Allard, R.C.E. 360 2 Date F CAI- RJA
(expires 6/30/2018)
.
er
�
o
1111aue 200J11100=11LO 11
SEWER IMPROVEMENT PLANS
TRACT NO. 18981
TITLE SHEET
CITY
)ATE: 7 %Z�
R.C.E. 51152
SCALE:
AS NOTED
DATE:
July, 2018
DRAWING NO.: 1
5697 7
Filename: 1:\Grand Pacific Communities - 339\1708981 Citrus and Curtis\DWG's\FINAL DESIGN\SEWER\SEWER PLAN TR 18981 SHT 1.dwg