HomeMy WebLinkAbout5623-2TRAFFIC SIGNAL CONSTRUCTION NOTES NOTE: SEESPECIAL PROVISIONS FOR ANY CITY SUPPLIED EQUIPMENT AND OR MATERIALS INSTALL CITY FURNISHED TYPE EQUIPMENT 90 CONTROLLER E Q PACKAGE INCLUDING. TYPE "R" CABINET AND APPURTENANT EQUIPMENT. CONTROLLER CABINET AND FOUNDATION SHALL BE INSTALLED PER CITY STANDARD 4001. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECTRONIC EQUIPMENT REQUIRED TO PROVIDE THE SIGNAL OPERATION AS SHOWN ON THE PLAN. 2 FURNISH AND INSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA AND SOUTHERNCALIFORNIA EDISON COMPANY REQUIREMENTS. FURNISH & INSTALL 2"C, 2#6, 1 #8 CONDUCTORS (SIGNAL SERVICE). FURNISH & INSTALL 2"C, 2#10 CONDUCTORS (LUMINAIRES). 5Q STUB OUT 2" CONDUIT TO P48 PULLBOX FOR SIC fi FURNISH AND INSTALL 3" PVC CONDUIT WITH 1 /4" POLY PULL ROPE PER SCE REQUIREMENTS. COORDINATE SERVICE WITH SCE PLANNING DEPARTMENT AT 90 - - 9 357 61 16. Ej NOT USED ® CONSTRUCT APPROX. 5'X18'X4" CONCRETE PAD WITHIN PARKWAY BETWEEN SIDEWALK AND CURB. 9 INSTALL CITY -FURNISHED UNI-DIRECTIONAL, SINGLE CHANNEL OPTICOM DETECTOR, PER DETAIL A THIS SHEET AND AS DIRECTED BY THE ENGINEER. CD 1a INSTALL CITY -FURNISHED UNI- DIRECTIONAL, SINGLE CHANNEL OPTICOM DETECTOR, PER DETAIL B THIS SHEET AND AS DIRECTED BY THE ENGINEER. 11 FURNISH AND INSTALL SIGNS AND HARDWARE PER CALTRANS DETAIL "U", ES-7N. 12 FURNISH AND INSTALL CCTV CAMERA PER CITY DESIGN STANDARD 4007 AND MANUFACTURERS REQUIREMENTS 3 0 REMOVE STREET LIGHT BY SCE AFTER SIGNAL IS ENERGIZED - ( ) SOUTH HIGHLAND 13 . / if . 177 A0 1�7 =-------------------- -- ----------- - -- --- ---- 207 104 285' TO 24 UMIT LINE X, C/G ,........ .......... .�....... ......... cry----� rxt�-,___ .. ........ .......... , 2 C -�2DLC ....,..,.., UGC ..,.,...H, UGC ..,.w..,..., ... Scit, n , ,..�,...,...� ,� .w.,.....,,, F,J .................„ ucc ..,, m., Ur . X,. /W NOTE: INTERCONNECT CONDUIT AND P48 SPLICE BOX INSTALLED PER DWG. #562A Curb/Berm flow lir or edge of shouldi 11 POLE LOCATION DETAIL O REV. REVISION DESCRIPTION DIAL TWO WORKING BEFORE DAYS BEFORE YOU DIG You nip TOLL FREE 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT P O L_ E S C H E D U L E L 0 C STANDARD MAST ARMS LUMLNAIRE ED P PUSH . BT. SIGNAL MOUNTING S. N. N P LACEMENT REMARKS TYPE HT. SIG. I . LUM. L.E.D. ` TYPE PHASE QUAD VEHICLE - POLE PED. MESSAGE A B A 26-4-1 0 0 30 45 15 111 W B 6 E - 2 MAS _ __ SV 1 T - _ SP 1 CS SEE BELOW A g , 4 - , F-15 B TYPE 1-A 10 - - - $ 8 S- - TV--1- T SP--1-CS - 9' 4 C 24-4-100 30 35 _15 111 W B 8 S - 1 MAS - - SV 1 T SP 1 CS SEE 'BELOW C 20 4 D TYPE 15-TS 30 - 1 ' 5 111 W B 2 W - - - SV 2 _ - SP 1 CS - -20 ' 4 E 26-4-100 30' 45' 15' 111 W B 2 W 2-MAS - - SV 1 T SP-1-CS SEE BELOW E 10' 4' - ' F-15 F TYPE 1-A 10 - - - B 4 N - - - TV 1 T - - SP 1 CS - 11 , 4 19 4 100 30 20 15 111 W B 4 N 1 MAS SV 1 T SP 1 CS SEE BELOW G 9 4 H TYPE 15-TS 30 - 15 111 W B 6 E - - SV 1 T - - SP 1 CS 8 4 1 I A I I I N ALL NEW EQUIPMENT NOTES: J I W E S.N.S. TO BE MOUNTED ON AN 8' SHAFT MOUNTED MAST ARM - I I I a s NOTE: POTHOLING REQUIRED FOR ALL POLES SPECIAL LENGTH MAST ARM I• c, I QUADRANT�k STRAIGHT LUMINAIRE ARM N I PED PUSH BUTTON LOCATION (TOP VIEW) I BARRIER Ave 2' 34' Cypress ( I Fo 6500 ! I v I y I I y I Ld Ld I I v I ! N � y I I 122 ! 34 I ICA I C 3t Ave S.Highland FONTANA 16500 Ave N I C1TY^ F C 1 V00 €} FONTANA 6600 B I R3-4flo 11 o co g I ' 10 08, 03 _gin d- PHASE DIAGRAM NOT ---,. USED-�- PHASE 1 PHASE 3 PHASE 4 NOT 4 �, USED �-► ..- -► P ASE PHA E PHASE 7 PHASE 8 CONDUCTOR TABLE AWG. CIRCUIT OR RUNS POLE 1 2 3 4 5 fi 7 8 9 POLE o � 1 1 m POLE 0 a U POLE O O v 0 POL E O 1 1 1 / 1 / Z 0 � POLE cv POLE r POLE POLE TOTAL 1 /1 2/2 3/3 4/4 -- 4/4 4/4 3/3 2/2 1 /1 and Ave In 16400 r - • i t' A • : ®.` ....................................................... .. WEEMBE a -- 8 I I I �. 2 L I IIs - w _17T I 408�-,` • I 08 ! I \, 3 03 1 I 108 I I o7 I 1,3 303 2t�3;; 04,07 .-- 9 ---; .04 01 DETECTOR — -- — 02 DETECTOR - 5 5 — 5 — — 03 DETECTOR -- 3 3 3 3 3 04 DETECTOR _ 4 _ - - _... - 05 DETECTOR _ _ - v o 06 DETECTOR - _ - _ 5 — 5 5 — 07 DETECTOR 3 08 DETECTOR 4 4 4 4 4 TOTAL - 5 5 — 24 — 12 12 7 7 304 I I I I FILL PERCENTAGE 9X 20X 28X 169� 17X 16X 26X 20X 23X 15X 0 II I ( I ALL CONDUCTORS ARE NEW. P8 14 f'* OPTICOM CABLE IS CITY -SUPPLIED aat �,„,,.,.....—�...cttas-.---,aau�-�-.. �c �� t�---�-s�s� �i •�--� sue---- cam--- �a�l` —` LC 06 - 06 ' cw D 5 S VICE f?OINT, �' �6 � • - ..�..�.. �.` ` �, ea�...,..�M.,_ ...�nis� `^ U�% _m,� _��: �,0� .; ..,. � a�'a � � .,.`"-...- •......" EDISON POLE #4337893E 906 H P I '� O / "X �' }.. .� SCALE: 1:20 .A � R�3-411 8.. I 2 I #6E N o V l 1 BIKE LOOP PLACEMENT & SAWCUT DETAIL 5 4 � 20� 20 fi t 4 1 I I IN ------------------------------- 5 I I 30' -15' 1,0, TYP TYP. TYP. TYP. y I I ffi I I I 10 I TYP. a LEGEND 4fi, low 0 PROPOSED SIGNAL- EQUIPMENT. — --- — —— — — - -— — —- -- - --� -- ------ --- Q PROPOSED TYPE E LOOP L I I! ---------------------------=-- i ® PROPOSED TYPE QC LOOP PER CITY STD. 4008 I I I J STOP BAR OR LEADING O PROPOSED PULLBOX I i ! 1 o EDGE OF CROSSWALK I I W 0z ! N � a I I � DATE ENGR. CITY DATE � � I I SHOULD CONSTRUCTION ! ON OF THE REQUIRED I N 5I I IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON I I AND CARRIED `FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE SEE DWG. No. 5624 FOR INTERCONNECT INSTALLATION PLAN PLANS TO BRING THE M INTO CONFORMANCE WITH SEE DWG. No. 5625 FOR SIGNING & STRIPING PLAN STANDARDS IN EFFECT. 20 10 0 20 40 60 R3 - 4 MAST.. —ARM MOUNTING OF MODEL 711 36 x36 OPTICAL DETECTOR O 3 4" CONDUIT T / TYP. 90 deg. SWEEP 15 ABOVE POLE BASE l DETAIL B SHAFT MOUNTING OF MODEL 711 OPTICOM DETECTOR SERVICE ADDRESS: 16493 SOUTH HIGHLAND AVENUE DOM tss o,�q� Prepared Under The Supervision Of: CITY OF FO N TA N A, CALIFORNIA F K IM Fy cy TRAFFIC SIGNAL AND LIGHTING PLAN DRAWN BY: SCALE: DT SOUTH HIGHLAND AVENUE 1:20 � No. 63106 DESIGNED BY:Ex . 6-30-20 DATE: DT CYP S AVENUE E 3/ 18/2019 CIVIL Date: `� CHECKEDBY: AP VED � , 'Z�'. DRAWING NO.: 2 gTFOFCAL�Fo� DH DATE: l Je Kim, R.C.E. 63106 GITY ENGINEERr , ; . 5623 2