Loading...
HomeMy WebLinkAbout5770-1SIGNING AND STRIPING GENERAL NOTE5 1. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA DEPARTMENT OF ENGINEERING PRIOR TO THE START OF ANY WORK. INSPECTION COORD/NA TION SHALL BE REQUESTED A T LEAST TWO WORKING DA YS PRIOR TO THE START OF ANY WORK /N PUBLIC RIGHT OF— WA Y W/ TH /N THE CITY LIMITS CALL (909) 350-7610. 2. ALL WORK, MATERIALS, EQUIPMENT AND TEMPORARY TRAFFIC CONTROL SHALL CONFORM TO THESE PLANS, THE CITY OF FONTANA DESIGN STANDARDS, THE CITY'S SPECIAL PROVISIONS, SECTION E, THE CALTRANS STANDARD PLANS AND SPECIFICATIONS, DATED 2015, THE REVISED CAL TRANS STANDARD PLANS AND SPECIFICATIONS, DATED 2016, AND THE CALIFORNIA MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES, DA TED 2014. J. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN TEMPORARY TRAFFIC CONTROL AT ALL TIMES 4. ALL SIGNS SHALL BE INSTALLED PER CITY DESIGN STANDARD 4003, UNLESS OTHERWISE SHOWN ON THE PLANS 5. ALL STRIPING AND PAVEMENT MARKINGS SHALL BE ALKYD THERMOPLASTIC UNLESS OTHERWISE NOTED. 6. SUBSTITUTE TYPE "C" RAISED PAVEMENT MARKERS FOR TYPE "G" MARKERS ON DETAIL 38 ON ROAD WA YS W/TH RAISED MEDIANS Z SUBSTITUTE DETAIL 14A STRIPING FOR DETAIL 12 STRIPING FOR ROADWAYS WITH RAISED MEDIANS 8. STRIPING AND PAVEMENT MARKINGS TO BE REMOVED SHALL BE REMOVED BY SANDBLAS77NG OR OTHER APPROVED METHODS, NONE OF WHICH SHALL DAMAGE THE PAVEMENT. THE 'BLACK OUT' METHOD OF REMOVAL /S NOT PERMITTED. ANY PAVEMENT DAMAGED BY REMOVALS SHALL BE REPAIRED PER APPROVAL OF THE C/TY ENGINEER AT NO COST TO THE C/TY. 9. CONTROL POINTS OR "CAT TRACKING" SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO APPLICATION OF PA VEMENT STRIPING AND LEGENDS NOTIFY THE CITY AT LEAST TWO DAYS PRIOR FOR APPROVAL OF "CAT TRACKING. " 10. STRIPING AND PA VEMENT MARKINGS SHALL BE APPLIED /N ACCORDANCE WITH MANUFACTURERS SPEC/FICA TONS. 11. BLUE RAISED PAVEMENT MARKERS SHALL BE INSTALLED AT ALL FIRE HYDRANT LOCATIONS PER CITY STANDARD PLANS 12. AS —BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS AND ELECTRONIC AUTOCAD FILES TO THE CITY ENGINEER. PRIVATE ENGINEER'S NOTICE TO THE CONTRACTOR: THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES, AND/OR STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS THESE LOCATIONS ARE APPROXIMATE AND SHALL BE CONFIRMED BY THE CONTRACTOR, SO THA T ANY NECESSARY ADJUSTMENT CAN BE MADE /N ALIGNMENT AND/OR GRADE OF THE PROPOSED IMPROVEMENT. THE CONTRACTOR /S REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT ANY UTILITY LINES SHOWN AND ANY OTHER LINES NOT ON RECORD OR NOT SHOWN ON THESE PLANS. CONSTRUCTION CONTRACTOR AGREES THAT /N ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, HE WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT INCLUDING THE SAFETY OF ALL PERSONS AND PROPERTY. THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AMD HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY,, REAL OR ALLEGED, IN CONNECTION WITH PERFORMANCE OF WORK ON THIS PROJECT, EXCEP77NG LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE DESIGN PROFESSIONAL. UNAUTHORIZED CHANGES AND USES THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR OR LIABLE FOR, UNAUTHORIZED CHANGES TO OR USE OF THESE PLANS ALL CHANGES TO THE PLANS MUST BE /N WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS CONSTRUCTION STAKING NOTICE THESE IMPROVEMENT PLANS HAVE BEEN PREPARED WITH THE INTENT THAT THE FIRM OF K&A ENGINEERING INC. WILL BE PERFORMING THE CONSTRUCTION STAKING FOR THE COMPLETE PROJECT HOWEVER, IF ANOTHER ENGINEERING AND/OR SURVEYING FIRM SHOULD BE EMPLOYED TO USE THESE PLANS FOR THE PURPOSE OF CONSTRUCTION STAKING, NOTICE /S HEREBY GIVEN THAT THE FIRM OF K&A ENGINEERING INC. WILL NOT ASSUME ANY RESPONSIBILITY FOR ERRORS OR OMISSIONS, WHICH COULD HAVE BEEN AVOIDED, CORRECTED OR M/T/GA TED /F K&A ENGINEERING INC. PERFORMED THE STAKING WORK. TOLL FREE -qmmmw- DIAL 811 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REV. I REVISION DESCRIPTION CITY OF FONTANA, UTILITY NOTIFICATION LI5T CITY OF FONTANA AT&T 8353 SIERRA AVENUE 22311 BROOKHORST STREET STE. 20J FONTANA, CA 92335 HUNTINGTON BEACH, CA 92646 (909) 350— 6632 (714) 963— 7964 SO. CALIF. GAS COMPANY SPRINT 1981 W. L UGON/A AVENUE 2592 DUPONT DRIVE REDLANDS, CA 92374 /RV/NE, CA 92612 (909) 335— 7967 (800) 659— 9698 EMERGENCIES: (800) 427-2200 TIME WARNER CABLE SO. CALIF. ED/SON COMPANY 1500 AUTO CENTER DRIVE 300 N. PEPPER AVENUE ONTARIO, CA 91761 RIALTO, CA 92376 (909) 975-3439 (909) 820-5598 — UNDERGROUND (909) 875-5100 — TRANSMISSION SUNESYS, LLC (213) 637-1233 — PIPELINES 1325 P/CO STREET 1106 (909) 357-6505 — DISTRIBUTION CORONA, CA 92881 (951) 278-0400 WEST VALLEY WATER DISTRICT UNDERGROUND SERVICE ALERT A TIN: ENG/NEER/NG DEPARTMENT 855 W. BASELINE ROAD (800) 422-4133 RIALTO, CA 92376 (909) 875-1804 DEVELOPER/OWNER LENNAR HOMES 980 MONTEC/TO DRIVE, SUITE 302 CORONA, CA 92879 (951) 817-3545 FAX (951) 817-3650 CA ld"V AL /CCO K&A ENGINEERING, INC 357 N. SHERIDAN STREET, SUITE 117 CORONA, CA 92880 PHONE: (951) 279-1800 SHEET INDEX SHEET DESCRIPTION NO. 1 77TLE SHEET 2 NAPA VALLEY ROAD — STA. 10+00 TO STA. 32+50 3 NAPA VALLEY ROAD — STA. 32+50 TO STA. 37+47 & MONTELENA DRIVE — STA. 10+00 TO STA. 29+50 4 MONTELENA DRIVE — STA. 29+50 TO STA. 37+26 & MENETO DRIVE — STA. 10+00 TO STA. 25+50 5 MENETO DRIVE — STA. 25+50 TO 36+50 ENGR, I DATE I CITY I DATE SHOULD CONSTRUCTION OF REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. 1' IL PREPARED fOR.• CITY OF FONTANA SUMMIT A T R 05ENA SIGNING AND STRIPING PLANS LENNAR HOMES 980 MON TECI TO DRIVE, SUITE 302 CORONA, CA 92879 (951) 817-3545 FAX (951) 817-3650 TRACT NO. 20153 i, 11 I I �11 •II :II BA5/5 OF BEARING - THE BASIS OF BEARINGS FOR THIS SURVEY IS THE EAST LINE OF THE SE 1/4 OF SECTION 19, ALSO BEING THE CENTERLINE OF SIERRA AVENUE, PER PARCEL MAP NO. 19434, P.M.B. 242/97-98. BEING: N00 3332 "W BENCHMARK: CAL TRANS BENCHMARK #8-17 BRASS DISK LOCATED IN S.C.E. TOWER LEG LOCATED 343' N/0 I-210, 0.2 MILES WEST OF SAN SEVAINE RDOAD. ELEVA TION= 1428.6 09 1 ENGINEERING 357 N. SHERIDAN STREET SUI TE 117 K LAND PLANNING CORONA, CALIFORNIA 92880 TEL. (951) 279-1800 5URMING FAX (951) 279-4380 Engineering, Inc. 01/23/19 AM/R H. FALLAHI , RCE 55534 DA TE /QFtOFESS/0\ � ( No. 55534 / lm civi\- OF�A PROJECT SITE CASA �Py GRANDE SUMMIT AVENUE 210 FREEWA Y za Q BASELINE ROAD s j Q Q Q FOOTHILL BLVD fib W Lu v v cn SAN BERNARDINO A VENUE INTERSTATE — 10 VICINITY MAP NOT TO SCALE CONSTRUCTION NOTES & QUANTITY ESTIMATE NO. DESCRIPTION UNIT QUANTITY INSTALL STOP SIGN PER CITY STD. PLAN NO. 4003 EA 18 INSTALL STREET NAME SIGN PER CITY STD. PLAN NO. 4003 EA 20 APPLY CONTINENTAL STYLE CROSSWALK (LONGITUDINAL BARS 24"X10' SPACED 24" APART) PER MUTCD FIG. 3B-19 LF 1760 APPLY 12" SOLID WHITE THERMOPLASTIC STOP BAR PER EA 6 CAL TRANS STD. PLAN A24E l2 APPLY YIELD SIGN PER MUTCD NO. R1-2 EA 16 l3 APPLY 4" WHITE THERMOPLASTIC EDGEL/NE EXTENSION PER CALTRANS STD.PLAN A20B (DETAIL 27C) 3' LONG 3' LF 635 APART l4 APPLY THERMOPLASTIC "YIELD" LEGEND PER CAL TRANS STD. EA 16 PLAN A24D 15 APPLY THERMOPLASTIC "STOP" LEGEND PER CAL TRANS STD. EA 6 PLAN A24D DESIGNED BY.- JS ORA WN BY JS/JC CHECKED BY.• CITY OF FONTANA, CALIFORNIA SIGNING & STRIPING PLAN SUMMIT AT ROSENA SCALE: TRACT NO.20153 DA rE, AS NOTED JAN 2019 DATE 2-12-2019 DRAWING NO. , RCE 51152 5770 A co 0