HomeMy WebLinkAbout5778-1GENERAL NOTES
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE
CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS
AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS
CONSTRUCTION ('GREEN BOOK"). ALL REFERENCE SPECIFICATIONS
AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE
NOTED.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT
DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO
PRECEDENCE PROVISIONS IN THE 'GREEN BOOK", THE CONTRACTOR
SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER
FOR RESOLUTION.
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE
CITY ENGINEER.
4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF
FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING
DIVISION PRIOR TO THE START OF ANY WORK.
INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO
WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC
RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL. (909) 350-7610.
5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL
POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF
CAUFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC
EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN
BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES.
7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION
OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH
FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5)
FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE
GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS
OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA.
TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN
THE POTENTIAL FOR GROUND MOVEMENT.
9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC
RIGHT-OF-WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR
THAT PURPOSE.
10. THE LOCATIONS OF U71LMES SHOWN HAVE BEEN DETERMINED FROM
AVAILABLE INFORMATION. HOWEVER, IT SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE
LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO
EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE
CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT
1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION.
11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL
UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS,
TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING,
LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER,
STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY
COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO
WORK AROUND THEIR FACILITIES.
12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER
MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION.
CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER
COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS.
13. CURVE DATA REFERS TO THE FACE OF CURB.
14. STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT
WHERE OTHERWISE NOTED.
15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE
ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK
TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE
FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION
CONTROL STAKING DURING CONSTRUCTION.
16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS,
MONUMENT TIES OR BENCHMARKS WITHOUT PRIOR NOTIFICATION TO
THE CITY ENGINEER.
17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING
SURVEY MONUMENTS, MONUMENT TIES AND BENCHMARKS, SHALL BE DONE
BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR.
SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF
THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL
NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO
THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER
REPLACEMENT OF THE MONUMENT.
18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS
AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL
BE MAINTAINED AT ALL TIMES IN TIME CONSTRUCTION AREA FOR
RESIDENTS AND EMERGENCY VEHICLES.
19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE
MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT
ALL TIMES.
20. ALL GRADING OPERATIONS SHALL BE DISCONTINUED WHEN SUSTAINED
WIND VELOCITIES EXCEED 25 MILES PER HOUR.
21. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD,
SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY
ADJACENT TO THE RIGHT-OF-WAY DURING CONSTRUCTION WITHOUT
PRIOR WRITTEN APPROVAL.
22. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL
OF THE CITY INSPECTOR.
23. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION.
FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE
RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED
DENSITY IS OBTAINED.
24. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES
FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE
SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODABLE
SWALES ENTERING OR LEAVING IMPROVEMENTS.
25. THE FINAL LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS
SHALL BE APPROVED AT THE TIME OF CONSTRUCTION AND SHALL
CONFORM TO THE CITY OF FONTANA STANDARD DETAILS.
26. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE,
COLOR AND FINISH TO MATCH EXISTING CONCRETE.
27. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF
THE CURB AT THE LOCATION OF THE SEWER LATERAL
28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING
STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED.
Q o REV. REVlS
y
- AAWAAAAAAAA
-
T 1 I I 1 1 1 I 1_ \ 'Z 7- V ---
TOLL
�IFRLEIEV 1-800-227--2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
i
29.
ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND
APPROVED PRIOR TO PAVING OF STREETS.
30.
APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT
PAVEMENT PRIOR TO PLACEMENT.
31.
PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT
TO REVISION AND APPROVAL OF THE CITY ENGINEER AS DETERMINED
BY SOILS TESTS TAKEN AFTER COMPLETION OF ROUGH GRADING.
32.
ACTUAL THICKNESS OF A.C. PAVEMENT AND/OR BASE COURSE MATERIAL
FOR STRUCTURAL STREET SECTIONS SHALL BE RECOMMENDED BY A
GEOTECHNICAL REPORT AND SUBMITTED TO THE CITY OF FONTANA
FOR APPROVAL UPON COMPLETION OF ROUGH GRADING.
33.
ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES
-
'
SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR'
- --
UPON COMPLETION OF PAVING.
-- • �
34.
UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE
ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC_
-
CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
- __-- -- ----- PR
CITY
35.
CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING,
SPRINKLERS AND SIDEWALKS AFFECTED BY THI•: CONSTRUCTION
-1 -
TO THE SATISFACTION OF THE CITY ENGINEER.
36.
AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO
POLEw
THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS
TO THE CITY ENGINEER.
CITY OF FONTANA, UTILITY NOTIFICATION LIST JOIN EXISTING
CITY OF FONTANA AT&T SIDEWALK 305'
8353 SIERRA AVE 22311 BROOKHURST ST SUITE 203 TO SOUTH
FONTANA, CA 92335 HUNTINGTON BEACH, CA 92646 CITY DWG 3247
(909) 350-6632 (714) 963-7964 SHEET (13)
SO. CALIF. GAS COMPANY SPRINT
1981 W. LUGONIA AVE 2592 DUPONT OR
REDLANDS, CA 92374 IRVINE, CA 92612
(909) 335-7967 (800) 659-9698
EMERGENCIES: (800) 427-2200
TIME WARNER CABLE
SO. CALIF. EDISON COMPANY 1500 AUTO CENTER OR
300 N. PEPPER AVE ONTARIO, CA 91761
RIALTO, CA 92376 (909) 975-3439
90L1 820-5598 - UNDERGROUND SUNESYS, LLC
909 875-5100 - TRANSMISSION 1325 PICO ST 1106
213 637-1233 - PIPELINES CORONA, CA 92881
909 357-6505 - DISTRIBUTION (951) 278-0400
WEST VALLEY WATER DISTRICT UNDERGROUND SERVICE ALERT
ATTN: ENGINEERING DEPARTMENT (800) 422-4133
855 W. BASELINE ROAD
RIALTO, CA. 92376
(909) 875-1804
PRIVATE ENGINEERPS NOTICE TO CONTRACTOR:
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES AND/OR STRUCTURES
SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS.
THESE LOCATIONS ARE APPROXIMATE AND SHALL BE CONFIRMED BY THE CONTRACTOR,
SO THAT ANY NECESSARY ADJUSTMENT CAN BE MADE IN ALIGNMENT AND/OR GRADE
OF THE PROPOSED IMPROVEMENT. THE CONTRACTOR IS REQUIRED TO TAKE DUE
PRECAUTIONARY MEASURES TO PROTECT ANY UTILITY LINES SHOWN AND ANY OTHER
LINES NOT ON RECORD OR NOT SHOWN ON THESE PLANS.
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED
CONSTRUCTION PRACTICES, HE WILL BE REQUIRED TO ASSUME
SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE
OF CONSTRUCTION OF THE PROJECT, INCLUDING THE SAFETY OF ALL PERSONS AND
PROPERTY. THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND
NOT BE LIMITED TO NORMAL WORKING HOURS. CONSTRUCTION CONTRACTOR FURTHER
AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY
AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF
WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE
OF THE DESIGN PROFESSIONAL.
UNAUTHORIZED CHANQS AND USES'
THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR OR LIABLE
FOR, UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS. ALL CHANGES TO THE
PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS.
CONSTRUCTION STAKING NOTICE
THESE IMPROVEMENT PLANS HAVE BEEN PREPARED WITH THE INTENT THAT THE FIRM OF
ALLARD ENGINEERING COMPANY WILL BE PERFORMING THE CONSTRUCTION STAKING FOR
THE COMPLETE PROJECT. IF, HOWEVER ANOTHER ENGINEERING AND/OR SURVEYING FIRM
SHOULD BE EMPLOYED TO USE THESE PLANS FOR THE PURPOSE OF CONSTRUCTION
STAKING, NOTICE IS HEREBY GIVEN THAT THE FIRM OF ALLARD ENGINEERING INCORPORATED
WILL NOT ASSUME ANY RESPONSIBILITY FOR ERRORS OR OMISSIONS, IF ANY, WHICH
MIGHT OCCUR AND WHICH COULD HAVE BEEN AVOIDED, CORRECTED OR MITIGATED IF
ALLARD ENGINEERING COMPANY HAD PERFORMED THE STAKING WORK.
CITY OF FONTANA
STREET IMPROVEMENT PLAN
TRACT 20082 W
17
SEE'ITY D� _ 247 (S�IEES ND 14)
LTA ISION.2�
---64+68ST -A
___._ __ _ __ --._....._._.._ .�.mm _.._ ._. __ __ -_ _30►N _EXISTING 0 RE IN
7- fIVD'1C S7'RriC1 STRI7CT"COR - -
)POSE'D--7--CO*IE 'ION__-__ ,EMaVE ME _ _.__ _.___.._
Uj 10
DW6 ( (i�)
,PAVEMENT-
- R�MOVE �1C _ � .� - -}---
+_ oo r`- IN MEDIA oo N "OWE
.. ! - __ ___ v
_ N
POLE+�9_. ,� . 00+ _ --- 0- ROTECT IN PLACE
_ P _ _ _ _ _ _ _ -PROTECT 1 l7rCE_ - - -C w _ -" -- - _. � _ - .� - - - - - _ _ �
TO
POWER POLE OIN EXISTING
- a _ , _ _ _ tom.... _ . a •- . -
LOT "C" LOT "B" JN 3 OTHERS
Ama
LOT "A"
61.88' 45,91' 0 1 � 24.01' 51.50' 51.00' 56.00' 67.00'
PROPOSED STORM DRAIN CONNECTION ,� + 10
CITY DWG 3249 (SHEETS (17) 10 N - `�
R=35 5 R=35
14
CIT11
I INUS AVENUE
WEST
R/W
GRAPHIC SCi4LE
* CONTRACTOR TO CONFIRM JOIN 40 0 20 40 80
ELEVATION & NOTIFY ENGINEER
PRIOR TO CONSTRUCTION. - - -- - - --
(Nf�T)
1 NCH : 40 FT.
ION DESCRIPTION DATE I ENGR.I CITY I DATE I PREPARED FOR:
TYPICAL SECTION
CITRUS AVENUE -104' R/W
NIS
T IAO.5
WEST
R/W
EAST
OLEANDER AVENUE
PROPOSED 6' SIDEWALK
i
EAST
R/W
68'
34'
34'
14' 20'
22' 12'
.5'
PROPOSED 5' SIDEWALK
160 TYPICAL SECTION
OLEANDER AVENUE - 68 R/W
NTS
IL--6.5
LE(�ND:
PROPOSED A.C. PAVEMENT
REMOVE EXISTING A.C. PAVEMENT
_
OVERLAY EXISTING A.C. PAVEMENT
- - -
CENTERLINE
RIGHT-OF-WAY LINE
- - - -
EXISTING IMPROVEMENTS
---(�}-
EXISTING CONTOUR LINE
L.O.S.
LINE OF SIGHT
SUMMIT AVENUE
FONTANA
STATE ROUTE - 210
WALNUT AVENUE
CHASE ROAD
BASELINE AVENUE
BROOK LANE
W
Z
PROJECT
LOCATION a
VICINITY MAP-
WS
00+t
,-...- _
CONSTRUCTION
QUANTITIES
1 CONSTRUCT 8" CURB ONLY PER CITY SDT. PLAN NO. 1000
285 LF
2 CONSTRUCT COMMERCIAL DRIVEWAY PER CITY STD. PLAN NO. 1002
1 EA.
3 CONSTRUCT CROSS GUTTER PER CITY STD. PLAN NO. 403
230 L.F.
4 GRIND EXISTING PAVEMENT AND OVERLAY FOR SMOOTH TRANSITION AS SHOWN
2,850 SF
PER TYPICAL PAVEMENT JOIN DETAIL
5 SAWCUT & REMOVE EXISTING AC PAVEMENT TO A CLEAN STRAIGHT LINE (1, MIN.)-.._
1,525 SF
6 REMOVE EXISTING CURB & GUTTER
330 LF
77 -CONSTRUCT 6.5" (MIN.) AC PAVEMENT OVER If OF 95% COMPARATIVE NATIVE
_ 1,875SF
PER CITY STD. 401. (SEE GENERAL NOTE 31 & 32)
®- CONSTRUCT 5" (MIN.) AC PAVEMENT OVER 12" OF 95X COMPARATIVE NATIVE
- 975 SF
PER CITY STD. 400. (SEE GENERAL NOTE 31 & 32)
�- CONSTRUCT 4" PCC SIDEWALK PER CITY STD. PLAN NO. 1006.
1,950 LF
10 CONSTRUCT CURB RETURN WITH ACCESS RAMP PER CITY STD. PLAN NO. 1003.
4 EA.
* CONTRACTOR IS RESPONSIBLE TO RELOCATE ALL EXISTING UTILITIES
INCLUDING IRRIGATION TO SATISFACTION OF CITY ENGINEER.
AC PAVEMENT OVERLAY
(MIN. 0.10' THICKNESS)
PROPOSED 1' 5'
AC PAVEMENT -�, MIN. MIN. ,r 0.10'
MIN. I
-GRIND EXIST.
SAWCUT AND REMOVE EXISTING AC PAVEMENT
EXISTING AC PAVEMENT AC PAVEMENT (MIN. 0.10' THICKNESS)
TYPICAL PAVEMENT JOIN DETAIL
NTS
SHOULD CONSTRUCTION OF REQUIRED Prepared By: RO�ES$,� CITY OF FONTANA CALIFORNIA
MOVEMENTS NOT COMMENCE WITHIN ALLARD ENGINEERING a oNo �. �4(Z STREET IMPROVEMENT PLAN
TWO YEARS OF THE DATE OF APPROVAL
Li�il Engineering -Land Surveying -Land Planning �� q `�� ��
SHOWN HEREON AND CARRIED FORTH IN A 16866 Seville Avenue co p z DRAWN BY: CITRUS AND OLEANDER AVENUE SCALE:
DILIGENT MANNER,THE CITY ENGINEER MAY Fontana, California 92335 No. 36052 AS NOTED
36310 INLAND VALLEY DRIVE''' "' DESIGNED BY: ? TRACT 20082 DATE:
WILDOMAR CA 92595 REQUIRE REVISIONS TO THE PLANS TO Ph. (909) 356- 815 Fax (909) 356-1795 Exp. 6/30/20
EQ /� APPRO � � January, 2019
TEL (951) 691-5193 BRING THEM INTO CONFORMANCE WITH 2cL 4(Q�P 1 •23 • (a s�QT c l v k �- CHECKED BY: DRAWING NO.:
FAX (951) 600-0136 CONDITIONS AND STANDARDS IN EFFECT Raymond J. Allard, A.C.E. 36052 Date F of CALF DATE: /' z
(expires 6/30/2020) 5778
CITY ENGINEER R.C.E. 51152
Flenome: I:\KB Homes\EI Paseo\DWG's\FINAL DESIGN\EXHIBIT'S\Driveway Exhibit.dwg