HomeMy WebLinkAbout5693-1TRAFFIC SIGNAL GENERAL NOTES
1. ALL WORK, MATERIALS, EQUIPMENT AND TEMPORARY TRAFFIC CONTROL SHALL
CONFORM TO THESE PLANS, THE CITY OF FONTANA DESIGN STANDARDS, THE CITY'S
SPECIAL PROVISIONS, SECTION E, THE CALTRANS STANDARD PLANS AND
SPECIFICATIONS, DATED 2015, THE REVISED CALTRANS STANDARD PLANS AND
SPECIFICATIONS, DATED 2016, AND THE CALIFORNIA MANUAL OF UNIFORM TRAFFIC
CONTROL DEVICES, DATED 2014.
2. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF
FONTANA ENGINEERING DIVISION PRIOR TO COMMENCENT OF WORK.
3. CONTRACTOR SHALL FURNISH ALL EQUIPMENT, MATERIALS, AND HARDWARE TO
CONSTRUCT THE TRAFFIC SIGNAL AND LIGHTING AS SHOWN ON THE PLANS, EXCEPT
ANY CITY FURNISHED OR PROVIDED AS NOTED IN SECTION E.
4. LOCATION OF ALL UNDERGROUND FACILITITES ARE APPROXIMATE. CONTRACTOR
SHALL BE RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ALL EXISTING
FACILITIES WITHIN THE AREA OF CONSTRUCTION. THE CITY ENGINEER SHALL BE
NOTIFIED OF ANY DISCREPENCIES OR CONFLICTS PRIOR TO COMMENCING WORK.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING
SURVEY MONUMENTS OR MARKERS DURING CONSTRUCTION.
6. ALL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 3" RIGID METAL UNLESS
OTHERWISE SHOWN.
7. ALL VEHICLE INDICATIONS SHALL BE 12" AND HAVE L.E.D. SIGNAL MODULES. ALL
PEDESTRIAN HEADS SHALL HAVE L.E.D. PEDESTRIAN MODULES & UTILIZE
PEDESTRAIN COUNTDOWN TIMERS PER SPECIAL PROVISIONS.
8. ANY EXISTING TRAFFIC SIGNALS AND LIGHTING SHALL REMAIN IN OPERATION UNTIL
REPLACED WITH NEW CONSTRUCTION.
9. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT
LOCATIONS PRIOR TO FINAL PLACEMENT. SEE DETAIL THIS SHEET AND SECTION E.
10. CONTROLLER AND SERVICE CABINETS SHALL NOT BE SUBJECTED TO WATER FROM
SPRINKLERS. CONTRACTOR SHALL MODIFY SPRINKLERS SYSTEMS AS NECESSARY.
11. CONTRACTOR SHALL INSTALL CITY —SUPPLIED REINFORCING CABLES AND ASSOCIATED
HARDWARE (2 PER SIGN) ON OVERHEAD REFLECTIVE STREET NAME SIGNS IN
ACCORDANCE WITH CITY DESIGN STANDARD 4005.
12. THE CONTRACTOR SHALL REPAIR/REPLACE/RELOCATE ANY AND ALL DAMAGED
LANDSCAPING, IRRIGATION, SIDEWALK, CURB, PAVEMENT OR ROADWAY STRIPING TO
THE SATISFACTION OF THE ENGINEER.
13. CONTRACTOR SHALL REFER TO THE CITY ENGINEER IN THE EVENT OF A CONFLICT
OR POTENTIAL CONFLICT WITH THESE PLANS AND/OR SPECIFICATIONS FOR THIS
PROJECT.
14. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER
OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS AND ELECTRONIC AUTOCAD
FILES TO THE CITY ENGINEER.
CALL AT LEAS'
TWO WORKING Dfn I
BEFORE YOU DIG
dvo
Know whairs below.
Call before you dig.
REV.
REVISION DESCRIPTION
CITY OF FONTANA
TRAFFIC SIGNAL PLAN
JURUPA AVENUE AND LIVE OAK AVENUE
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
PLANS TO BRING THEM INTO CONFORMANCE WITH
DATE ENGR. CITY DATE STANDARDS I N EFFECT.
VICINITY MAP
NOT TO SCALE
SLOVER AVE
INDEX OF SHEETS:
SHEEP 1 -TITLE SHEET
SHEEP 2 -TRAFFIC SIGNAL PLAN
DRAWING NUMBER
5692 —STREET IMPROVEMENT PLAN
5693 —TRAFFIC SIGNAL PLAN
5694 —SIGNING AND STRIPING PLAN
TRAFFIC SIGNAL CONSTRUCTION NOTES
a INSTALL CITY FURNISHED TYPE 90 CONTROLLER EQUIPMENT PACKAGE INCLUDING
TYPE 'R" CABINET, LOOP DETECTION, AND APPURTENANT EQUIPMENT. CONTROLLER
CABINET AND FOUNDATION SHALL BE INSTALLED PER CITY STANDARD PLAN 4001.
CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL EQUIPMENT REQUIRED
TO PROVIDE THE SIGNAL OPERATION AS SHOWN ON THE PLAN.
F21 FURNISH AND INSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF
FONTANA AND SOUTHERN CALIFORNIA EDISON COMPANY REQUIREMENTS.
3❑ FURNISH &INSTALL 2"C, 2#6, 1#8 CONDUCTORS (SIGNAL SERVICE).
El FURNISH &INSTALL 2"C, 2#10 CONDUCTORS (LUMINAIRES).
El FURNISH AND INSTALL 3" PVC CONDUIT WITH Y4" POLY PULL ROPE PER SCE
REQUIREMENTS. COORDINATE SERVICE WITH SCE PLANNING DEPARTMENT AT
909.357.6516. VERIFY PHONE NUMBERS AT TIME OF CONSTRUCTION.
❑6 REMOVE EXISTING LANDSCAPING AND MODIFY IRRIGATION SYSTEM AS NECESSARY.
CONSTRUCT 4" THICK PCC PAD ON COMPACTED NATIVE AROUND PROPOSED SIGNAL
CONTROLLER AND SERVICE CABINETS. SPRINKLERS SHALL NOT SPRAY ONTO
CONTROLLER CABINET OR SERVICE PEDESTAL.
ElINSTALL CITY -FURNISHED UNI-DIRECTIONAL, SINGLE CHANNEL OPTICOM DETECTOR,
AS DIRECTED BY THE ENGINEER.
0 INSTALL SIGN AND HARDWARE PER CALTRANS DETAIL "U", ES-7N.
Q FURNISH AND INSTALL SIX (6) 1-1/2" HIGH DENSITY POLYETHYLENE(HDPE) CONDUITS
BY DIRECTIONAL BORING UNDER PAVEMENT OR SIDEWALK, OR BY TRENCHING IN SOIL.
CONDUITS SHALL BE COLOR CODED ORANGE, YELLOW, BLACK, BLUE AND GREEN.
FURNISH AND INSTALL ONE POLYESTER MULETAPE IN EACH EMPTY CONDUIT FOR
FUTURE CABLE. CONDUIT SWEEPS SHALL BE INSTALLED WITH A MINIMUM OF A 10'
RADIUS.
10 FURNISH AND INSTALL 96 STRAND SMFO CABLE IN ORANGE CONDUIT.
Fill FURNISH AND INSTALL 2" CONDUIT WITH 1-12 STRAND SINGLE MODE FIBER OPTIC
CABLE.
n12 FURNISH AND INSTALL P48 SPLICE VAULT. COIL 50' OF 96 STRAND SMFO AND 25'
OF 12 STRAND SMFO CABLE.
13 FURNISH AND INSTALL SPLICE ENCLOSURE, TERMINATE 12 STRAND TO 96 STRAND
SMFO CABLE (OR 96 STRAND SMFO CABLE TO 96 STRAND SMFO CABLE) PER SPLICE
CHART PROVIDED BY CITY. SPLICE THROUGH ALL 96 STRAND SMFO FIBERS TO
EXISTING 96 STRAND SMFO FIBERS.
14 FURNISH AND INSTALL P48 SPLICE VAULT EVERY 500' WITHIN EACH SPLICE VAULT,
COIL 50' OF 96 STRAND SMFO CABLE.
15 FURNISH AND INSTALL WALL INTERCONNECT UNIT. TERMINATE 12 STRAND SMFO
CABLE PER SPLICE CHART.
16 FURNISH AND INSTALL CCTV CAMERA PER CITY STANDARD PLAN 4007 AND
MANUFACTURERS SPECIFICATIONS.
17 TERMINATE CCTV ETHERNET CABLE INSIDE CONTROLLER CABINET PER
MANUFACTURERS SPECIFICATIONS.
18 TERMINATE 6-PACK CONDUITS TO NEW SPLICE VAULT.
19 FURNISH AND INSTALL P48 SPLICE VAULT.
n2O FURNISH AND INSTALL 12 STRAND SMFO CABLE IN EXISTING CONDUIT.
n2l FURNISH AND INSTALL 2" CONDUIT FROM NEW P48 SPLICE VAULT TO EXISTING #6
PULLBOX. PULL IN 12 STRAND SMFO CABLE THROUGH EXISTING SIGNAL CONDUIT TO
CONTROLLER CABINET.
ncB INSTALL CONDUIT INTO EXISTING PULLBOX.
SIGN LEGEND:
R3-4
LEGEND:
0
0
PROPOSED SIGNAL EQUIPMENT
PROPOSED TYPE E LOOP
of '�i IMi i '
SERVICE ADDRESS: 14891 JURUPA AVE, FONTANA CA 92337
Prepared Under The Supervision Of :
CITY OF FONTANA, CALIFORNIA
eRpF E SSIp*
`X,G G�,q �Fy
ti �y
K41AA
3190 C Shelby Street
TITLE SHEET
DRAWN BY:
JURUPA AVENUE
SCALE:
No. 75793 �
�c EXP. 6j30j20
Ontario, California 91764
Tel: (909) 890-9693 Fax. (909) 890-9694
DA
A
"IVFz?OAVE
As Noted
DESIGNED BY:
AO
DATE:
BENCH MARK: B.M. NO. 248 ELEVATION=951.68'
sT9r£0F w�LEFp���P
CA
DESCRIPTION: THE BENCHMARK FOR THIS SURVEY 1S CITY OF FONTANA BENCHMARK 248 BEING A
RAIL ROAD SPIKE SET IN POWER POLE FOR #363E, 75FT WEST OF LIVE OAK AVE
AND 35FT NORTH OF CENTERLINE JURUPA AVE.
Date : , ! /1
CHECKED BY:
MG
APPR ED BY: / /
! DATE: `� ' ( •
DRAWING NO.:
5693
1
MING GUAN. R.C.E. 75793
MY FN(;INFFR R (� F .�i1 159
2