HomeMy WebLinkAbout5693-1TRAFFIC SIGNAL GENERAL NOTES 1. ALL WORK, MATERIALS, EQUIPMENT AND TEMPORARY TRAFFIC CONTROL SHALL CONFORM TO THESE PLANS, THE CITY OF FONTANA DESIGN STANDARDS, THE CITY'S SPECIAL PROVISIONS, SECTION E, THE CALTRANS STANDARD PLANS AND SPECIFICATIONS, DATED 2015, THE REVISED CALTRANS STANDARD PLANS AND SPECIFICATIONS, DATED 2016, AND THE CALIFORNIA MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES, DATED 2014. 2. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA ENGINEERING DIVISION PRIOR TO COMMENCENT OF WORK. 3. CONTRACTOR SHALL FURNISH ALL EQUIPMENT, MATERIALS, AND HARDWARE TO CONSTRUCT THE TRAFFIC SIGNAL AND LIGHTING AS SHOWN ON THE PLANS, EXCEPT ANY CITY FURNISHED OR PROVIDED AS NOTED IN SECTION E. 4. LOCATION OF ALL UNDERGROUND FACILITITES ARE APPROXIMATE. CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ALL EXISTING FACILITIES WITHIN THE AREA OF CONSTRUCTION. THE CITY ENGINEER SHALL BE NOTIFIED OF ANY DISCREPENCIES OR CONFLICTS PRIOR TO COMMENCING WORK. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING SURVEY MONUMENTS OR MARKERS DURING CONSTRUCTION. 6. ALL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 3" RIGID METAL UNLESS OTHERWISE SHOWN. 7. ALL VEHICLE INDICATIONS SHALL BE 12" AND HAVE L.E.D. SIGNAL MODULES. ALL PEDESTRIAN HEADS SHALL HAVE L.E.D. PEDESTRIAN MODULES & UTILIZE PEDESTRAIN COUNTDOWN TIMERS PER SPECIAL PROVISIONS. 8. ANY EXISTING TRAFFIC SIGNALS AND LIGHTING SHALL REMAIN IN OPERATION UNTIL REPLACED WITH NEW CONSTRUCTION. 9. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. SEE DETAIL THIS SHEET AND SECTION E. 10. CONTROLLER AND SERVICE CABINETS SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. CONTRACTOR SHALL MODIFY SPRINKLERS SYSTEMS AS NECESSARY. 11. CONTRACTOR SHALL INSTALL CITY —SUPPLIED REINFORCING CABLES AND ASSOCIATED HARDWARE (2 PER SIGN) ON OVERHEAD REFLECTIVE STREET NAME SIGNS IN ACCORDANCE WITH CITY DESIGN STANDARD 4005. 12. THE CONTRACTOR SHALL REPAIR/REPLACE/RELOCATE ANY AND ALL DAMAGED LANDSCAPING, IRRIGATION, SIDEWALK, CURB, PAVEMENT OR ROADWAY STRIPING TO THE SATISFACTION OF THE ENGINEER. 13. CONTRACTOR SHALL REFER TO THE CITY ENGINEER IN THE EVENT OF A CONFLICT OR POTENTIAL CONFLICT WITH THESE PLANS AND/OR SPECIFICATIONS FOR THIS PROJECT. 14. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS AND ELECTRONIC AUTOCAD FILES TO THE CITY ENGINEER. CALL AT LEAS' TWO WORKING Dfn I BEFORE YOU DIG dvo Know whairs below. Call before you dig. REV. REVISION DESCRIPTION CITY OF FONTANA TRAFFIC SIGNAL PLAN JURUPA AVENUE AND LIVE OAK AVENUE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH DATE ENGR. CITY DATE STANDARDS I N EFFECT. VICINITY MAP NOT TO SCALE SLOVER AVE INDEX OF SHEETS: SHEEP 1 -TITLE SHEET SHEEP 2 -TRAFFIC SIGNAL PLAN DRAWING NUMBER 5692 —STREET IMPROVEMENT PLAN 5693 —TRAFFIC SIGNAL PLAN 5694 —SIGNING AND STRIPING PLAN TRAFFIC SIGNAL CONSTRUCTION NOTES a INSTALL CITY FURNISHED TYPE 90 CONTROLLER EQUIPMENT PACKAGE INCLUDING TYPE 'R" CABINET, LOOP DETECTION, AND APPURTENANT EQUIPMENT. CONTROLLER CABINET AND FOUNDATION SHALL BE INSTALLED PER CITY STANDARD PLAN 4001. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL EQUIPMENT REQUIRED TO PROVIDE THE SIGNAL OPERATION AS SHOWN ON THE PLAN. F21 FURNISH AND INSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA AND SOUTHERN CALIFORNIA EDISON COMPANY REQUIREMENTS. 3❑ FURNISH &INSTALL 2"C, 2#6, 1#8 CONDUCTORS (SIGNAL SERVICE). El FURNISH &INSTALL 2"C, 2#10 CONDUCTORS (LUMINAIRES). El FURNISH AND INSTALL 3" PVC CONDUIT WITH Y4" POLY PULL ROPE PER SCE REQUIREMENTS. COORDINATE SERVICE WITH SCE PLANNING DEPARTMENT AT 909.357.6516. VERIFY PHONE NUMBERS AT TIME OF CONSTRUCTION. ❑6 REMOVE EXISTING LANDSCAPING AND MODIFY IRRIGATION SYSTEM AS NECESSARY. CONSTRUCT 4" THICK PCC PAD ON COMPACTED NATIVE AROUND PROPOSED SIGNAL CONTROLLER AND SERVICE CABINETS. SPRINKLERS SHALL NOT SPRAY ONTO CONTROLLER CABINET OR SERVICE PEDESTAL. ElINSTALL CITY -FURNISHED UNI-DIRECTIONAL, SINGLE CHANNEL OPTICOM DETECTOR, AS DIRECTED BY THE ENGINEER. 0 INSTALL SIGN AND HARDWARE PER CALTRANS DETAIL "U", ES-7N. Q FURNISH AND INSTALL SIX (6) 1-1/2" HIGH DENSITY POLYETHYLENE(HDPE) CONDUITS BY DIRECTIONAL BORING UNDER PAVEMENT OR SIDEWALK, OR BY TRENCHING IN SOIL. CONDUITS SHALL BE COLOR CODED ORANGE, YELLOW, BLACK, BLUE AND GREEN. FURNISH AND INSTALL ONE POLYESTER MULETAPE IN EACH EMPTY CONDUIT FOR FUTURE CABLE. CONDUIT SWEEPS SHALL BE INSTALLED WITH A MINIMUM OF A 10' RADIUS. 10 FURNISH AND INSTALL 96 STRAND SMFO CABLE IN ORANGE CONDUIT. Fill FURNISH AND INSTALL 2" CONDUIT WITH 1-12 STRAND SINGLE MODE FIBER OPTIC CABLE. n12 FURNISH AND INSTALL P48 SPLICE VAULT. COIL 50' OF 96 STRAND SMFO AND 25' OF 12 STRAND SMFO CABLE. 13 FURNISH AND INSTALL SPLICE ENCLOSURE, TERMINATE 12 STRAND TO 96 STRAND SMFO CABLE (OR 96 STRAND SMFO CABLE TO 96 STRAND SMFO CABLE) PER SPLICE CHART PROVIDED BY CITY. SPLICE THROUGH ALL 96 STRAND SMFO FIBERS TO EXISTING 96 STRAND SMFO FIBERS. 14 FURNISH AND INSTALL P48 SPLICE VAULT EVERY 500' WITHIN EACH SPLICE VAULT, COIL 50' OF 96 STRAND SMFO CABLE. 15 FURNISH AND INSTALL WALL INTERCONNECT UNIT. TERMINATE 12 STRAND SMFO CABLE PER SPLICE CHART. 16 FURNISH AND INSTALL CCTV CAMERA PER CITY STANDARD PLAN 4007 AND MANUFACTURERS SPECIFICATIONS. 17 TERMINATE CCTV ETHERNET CABLE INSIDE CONTROLLER CABINET PER MANUFACTURERS SPECIFICATIONS. 18 TERMINATE 6-PACK CONDUITS TO NEW SPLICE VAULT. 19 FURNISH AND INSTALL P48 SPLICE VAULT. n2O FURNISH AND INSTALL 12 STRAND SMFO CABLE IN EXISTING CONDUIT. n2l FURNISH AND INSTALL 2" CONDUIT FROM NEW P48 SPLICE VAULT TO EXISTING #6 PULLBOX. PULL IN 12 STRAND SMFO CABLE THROUGH EXISTING SIGNAL CONDUIT TO CONTROLLER CABINET. ncB INSTALL CONDUIT INTO EXISTING PULLBOX. SIGN LEGEND: R3-4 LEGEND: 0 0 PROPOSED SIGNAL EQUIPMENT PROPOSED TYPE E LOOP of '�i IMi i ' SERVICE ADDRESS: 14891 JURUPA AVE, FONTANA CA 92337 Prepared Under The Supervision Of : CITY OF FONTANA, CALIFORNIA eRpF E SSIp* `X,G G�,q �Fy ti �y K41AA 3190 C Shelby Street TITLE SHEET DRAWN BY: JURUPA AVENUE SCALE: No. 75793 � �c EXP. 6j30j20 Ontario, California 91764 Tel: (909) 890-9693 Fax. (909) 890-9694 DA A "IVFz?OAVE As Noted DESIGNED BY: AO DATE: BENCH MARK: B.M. NO. 248 ELEVATION=951.68' sT9r£0F w�LEFp���P CA DESCRIPTION: THE BENCHMARK FOR THIS SURVEY 1S CITY OF FONTANA BENCHMARK 248 BEING A RAIL ROAD SPIKE SET IN POWER POLE FOR #363E, 75FT WEST OF LIVE OAK AVE AND 35FT NORTH OF CENTERLINE JURUPA AVE. Date : , ! /1 CHECKED BY: MG APPR ED BY: / / ! DATE: `� ' ( • DRAWING NO.: 5693 1 MING GUAN. R.C.E. 75793 MY FN(;INFFR R (� F .�i1 159 2