HomeMy WebLinkAbout5744-1GENERAL NOTES
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS,
THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION
("GREEN BOOK"), ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION
UNLESS OTHERWISE NOTED.
2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA ENGINEERING DIVISION
PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO
WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS.
CALL (909) 350-7610,
3. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES. CONTRACTOR
SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER
REQUIREMENTS.
4. STATIONING REFERS TO THE CENTERLINE OF STORM DRAIN EXCEPT WHERE OTHERWISE NOTED.
5. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF
STREETS.
6. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION,
HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE
TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION
TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT
1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION.
7. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED
GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING.
8. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT
NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE
IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND
CALTRANS_ ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK
AROUND THEIR FACILITIES.
9. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD,
WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
10. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED
BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY
REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
11. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT.
12. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH
EXISTING CONCRETE.
12A. ALL REINFORCED CONCRETE SHALL BE 3,250 PSI, AT 28 DAYS, PORTLAND CEMENT TYPE IV.
13. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED,
INSPECTED AND APPROVED.
14, THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE
GUARDED BY SHORING, SLOPING OF THE GROUND OR (OTHER APPROVED MEANS PURSUANT TO THE
REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES
LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND
SAFETY
15. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES
(5) FEET OR GREATER IN DEPTH FROM THE CA-L IFORNIA STATE DIVISION OF INDUSTRIAL SAFETY-
16. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
17. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE
DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF' WAY DURING
CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL.
18. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS
OR OTHER TRAFFIC CONTROL Dr_ VICES AT ALL TIMES.
19. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE
REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE
SPECIFIED DENSITY IS OBTAINED.
20. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
21. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE
THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING
DURING CONSTRUCTION.
22. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET
IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY
NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
23. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS,
THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY.
24. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH
MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
25. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS,
MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY. A REGISTERED CIVIL ENGINEER OR
LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS
CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK
PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER
REPLACEMENT OF THE MONUMENT.
26. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES.
A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CLOSURE AREA FOR RESIDENTS
AND EMERGENCY VEHICLES.
27, NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING
A SEPARATE PERMIT FOR THAT PURPOSE.
28. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY
ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING
FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS.
29. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL,
INCLUDING ADEQUATE WATERING, AT ALL TIMES.
30. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES
DESCRIBED IN THE "W.A.T.C.H. MANUAL". LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE
CITY TRAFFIC ENGINEER.
31. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RES I ORE ALL SIGNING, STRIPING,
BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC
ENGINEER.
32. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR
OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES,
33, NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF
THE CITY ENGINEER.
34, MINIMUM D-LOAD FOR ALL RCP STORM DRAIN PIPE IS 1350.
35. THE CONCRETE COATING ON THE INSIDE OF ALL REINFORCED CONCRETE PIPES
MUST BE INCREASED TO PROVIDE A MINIMUM OF 1-1/2" OVER THE REINFORCING
WHEN THE DESIGN VELOCITIES EXCEED 20 FEET PER SECOND. THE CONCRETE
DESIGN STRENGTH IN THESE REACHES SHALL BE Fc=5000 psi FOR VELOCITIES
EXCEEDING 20 FEET PER SECOND AND Fc=6000 psi FOR VELOCITIES EXCEEDING
30 FEET PER SECOND.
36. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT
SHALL BE IN PLACE ONE WEEK PRIOR TO IMPLEMENTING DETOURS,
DIALI
DIAL TWO WORKING
BEFORE DAYS BEFORE
YOU DIG YOU DIG
TOLL FREE: 811 INWYV.DIGALERT.ORG
A PUBLIC SERVICE BY
UNDERGROUND SERVICE ALERT
B _3
/_ S OF BEARINGS:
THE BEARINGS SHOWN HEREON ARE BASED ON THE
CENTERLINE OF VALLEY BOULEVARD BEING NORTH 89' 43'
59" EAST ON PARCEL MAP 19511, P.M.B. 243/64-65
7j7 7R W
T-L), 7 �_ A� T, � T W, 7 R 7) W _71vq'T� LA3 �N
OWNER/DEVELOPER
SEEFRIED INDUSTRIAL PROPERTIES
2301 ROSECRANS AVENUE, SUITE 3165
EL SEGUNDO, CA 90254
PH: 310-536-7900
CONTACT: DAN BICK
CIVIL ENGINEER
HUITT- OLLARS, INC
3990 CONCOURS, #330
ONTARIO, CA, 91761
PHONE (909) 941-7799
FAX (909) 941-7789
CONTACT: JOHNNY MURAD
UTILITY C 0 N T A C'
�4 ;f-§T a
E s�i i a
SOUTHERN CALIFORNIA EDISON
7951 REDWOOD AVENUE
FONTANA, CA 92336
(909) 357-6203
WATER
FONTANA WATER CO.
15966 ARROW ROUTE
FONTANA, CALIFORNIA 92335
(909) 822-2201
GAS
SOUTHERN CALIFORNIA GAS CO.
1981 W. LUGONIA AVENUE
REDLANDS, CA 92374
(800) 427-2200
BENCHMARK:
THE BENCHMARK FOR THIS CITY OF FONTANA
BENCHMARK NO. 322
NGVD29, ELEVATION=1104.49'
CHISELED "X" IN THE EAST END OF THE
SOUTHEAST CURB RETURN AT THE
INTERSECTION OF CITRUS AVE. AND HUNTER
STREET
NOTE
7) (Q 7,711 7�1 - " " ' " " (5 �'
7 L.-A el L!l W �A T Ail
7(07�`LA7R �57(CXRW 7P7RA7U9
(QTTT (07T 7F(07( TTA7NA
STORM DRAIN CONSTRUCTION NOTES
THE QUANTITIES SHOWN HEREON ARE ESTIMATES ONLY. THE CONTRACTORS SHALL PREPARE
THEIR OWN QUANTITIES AND BID A COMPLETE JOB.
A. CONTRACTOR TO ADJUST ALL VALVE COVERS AND MANHOLE RIMS TO GRADE
AFTER FINAL PAVING HAS BEEN INSTALLED.
QUANTITIES
DDT
INSTALL 30" ADS HP STORM PIPE PER TRENCH INSTALLATION DETAIL ON SHEET 3_...................................
217
LF
D50
CONSTRUCT CURB OPENING CATCH BASIN PER CITY OF FONTANA STD. 3004
(WIDTH & V-DEPTH PER PLAN) ........................................................................ ......
......
... 1
EA
,, 8
CONSTRUCT MANHOLE PER CITY OF FONTANA STD. PLAN 3Q12....... ..
1
EA
659,
CONSTRUCT MANHOLE PER CITY OF FONTANA STD, PLAN 3013.................................................
.............. 1
EA
G
PROTECT IN PLACE (ITEM AS INDICATED ON PLAN) .................
N/A
D 331
SAWCUT AND REMOVE EXISTING AC/AB AND REPLACE IN KIND AFTER
STORM DRAIN INSTALLATION, LIMITS AS INDICATED ON PLAN.... ...... ........... .............................
..............1,062
SF
D136
CONSTRUCT LOCAL DEPRESSION AT CATCH BASIN PER CITY OF FONTANA
STD. PLAN 3003 (CASE B), H=4" AND DETAIL ON SHEET 2 ....
1
EA
Dim
CONSTRUCT PIPE TO CHANNEL CONNECTION PER DETAIL ON SHEET 3........................................................
2
EA
D1�
INSTALL ADS 30" HP DUAL WALL FABRICATED 45' BEND(3094APN).........................................................
2
EA
D2�
REMOVE EXISTING CURB AND GUTTER............................................................... ......
...... 34
LF
D22�
REMOVE AND REPLACE CURB AND GUTTER...........................................................................
.............. 10
LF
D287
REMOVE AND CONSTRUCT CHAIN LINK FENCE PER CALTRANS 2018 STANDARD
PLAN A85, A85A AND A85B............................................................................................................
20
LF
D389
REMOVE EXISTING GROUTED RIP-RAP...............................................................................................
- 270
SF
F a
e I i
PHONE
TE E I
a ��
AT&T
3939 E CORONADO STREET
ANAHEIM, CA 92807 I
(714) 237-6155 I
i
SEWER I
CITY OF FONTANA
8353 SIERRA AVENUE i a LINE B
FONTANA, CA 92335
(909) 350-6632 "EET
LINE E
CABLE LSH 2 PROP. 36" SD LINE R
_ E_21RLCJ�E GRADING PLANS
SPECTRUM 1500 AUTO CENTER DRIVEIONTARIO, CA 91761BIJO) 892-2253 I _ ��PROP. 24" SD LINE E
SEE PRECISE GRADING PLANS
-
+"ALTRANS R '"" "-
1 / '*-'--CALTRANS R/W
CALTRANS ,j CITY DE FONTANA R/W ' �; r
FL
STATE HI IO Y} 1 1 � i..
a
SHEET INDEX MAP IN
SCALE: 1 "=60'
CALTRANS' NOTES:
1. ALL WORKS WITHIN CALTRANS RIGHT-OF-WAY SHALL COMPLY WITH THE LATEST EDITION OF
CALTRANS HIGHWAY DESIGN MANUAL, 2018 CALTRANS STANDARD PLANS AND SPECIFICATION
2. WHERE DAMAGE IS CAUSED BY THE CONTRACTOR'S OPERATION, THE CONTRACTOR SHALL, AT HIS
OWN EXPANSE, REPAIR OR REPLACE DAMAGE FACILITIES PROMPTLY IN ACCORDANCE WITH STATE
SPECIFICATION AND/ OR AS DIRECTED BY CALTRANS REPRESENTATIVE.
REVISION DESCRIPTION
NO.
DATE I ENGR. I CITY I DATE
SHOULD CONSTRUCTION OF THE
REQUIRED IMPROVEMENTS NOT
COMMENCE WITHIN TWO YEARS
OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED
FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE
REVISIONS TO THE PLANS -10
BRING THEM INTO CONFORMANCE
\v'ITH STANDARDS IRv EF F � _T.
��OFESSI®Nq
F��
N0. 67512
EXPIRATION
6--30-2019
ET INDEX
SHT NO.
DESCRIPTION
1
TITLE SHEET
2
POPLAR AVE. STORM DRAIN PLAN AND PROFILE
3
STORM DRAIN DETAILS
_f _FZOLL)V6
ul
Huitt-Zollars, Inc. Ontario
3990 CONCOURS, #330 * ONTARIO, CALIFORNIA 91761 * (909) 941-7799
F_'ARED UNDER THE SUPERVISION OF: JOHNNY MURAD
67512 0®30-19 It
R.C.E. EXPIRES
LEGEND
PROJECT
LIMITS
�v w
P �
PAP Q
Q
m
O�
N
J �
D_ Q
�
VALLEY BLVD a -
[To]
SLOVER AVE
VICINITY MAP N
NOT TO SCALE
LEGEND
- -
EXISTING R/W
- _
PROPOSED R/W
EASEMENT
CENTER LINE
FIRE HYDRANT
R
PROPERTY LINE
R/W ..........
RIGHT OF WAY
C .........
CENTERLINE
BOT.
BOTTOM
SD . ......
STORM DRAIN
SMH .........
SEWER MANHOLE
STD .........
STANDARD
SEW .........
SEWER
TYP...........
TYPICAL
IMP...........
IMPROVEMENT
P.I.P...... ...
PROTECT IN PLACE
DWG .........
DRAWING
EXIST.........
. EXISTING
RW ..........
RECYCLED WATER
INV .........
INVERT OF PIPE
UT . - .....
UTILITY
MH .........
MANHOLE
SPPWC.........
STANDARD PLANS FOR
PUBLIC WORKS CONSTRUCTION
PROPOSED STORM DRAIN
-
EXISTING SEWER
EXISTING WATER
EXISTING RECYCLED WATER
EXISTING STORM DRAIN
EXISTING GAS
EXISTING TELEPHONE
EXISTING ELECTRICAL
EASEMENT
TRENCH REPAIR
UNAUTHORIZED CHANGES AND USES NOTESm
CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR LIABLE
FOR, UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS.
CITY ACCEPTANCE OF PLANS DOES NOT RELIEVE THE DEVELOPER FROM RESPONSIBILITY FOR
THE CORRECTION OF ERRORS AND OMISSIONS DISCOVERED DURING CONSTRUCTION. UPON
REQUEST OF THE CITY INSPECTOR, THE REQUIRED PLAN REVISIONS SHALL BE PROMPTLY
SUBMITTED TO THE CITY ENGINEER FOR REVIEW.
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED
CONSTRUCTION PRACTICES CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE
AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF
CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT
THIS REQUIREMENT SHALL BE MADE TO APPLY CONTI,NIUOUSLY AND N`1T BE LIMITED TO
NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND,
INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY ADD ALL LIABILITY: REAL
OR ALLEGED. IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTIi�=G
LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF DESIGN PROFESSIONAL.
PRIVATE ENGINEERS NOTICE TO CONTRACTORS
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON
THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR
KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES
SHOWN AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE PLANS.
ALL CONTRACTORS AND SUBCONTRACTORS PERFORMING WORK SHOWN ON OR RELATED TO THESE
PLANS SHALL CONDUCT THEIR OPERATIONS SO THAT ALL EMPLOYEES ARE PROVIDED A SAFE PLACE
TO WORK AND THE PUBLIC IS PROTECTED. ALL CONTRACTORS AND SUBCONTRACTORS SHALL
COMPLY WITH THE 'OfUPA.TIONAL SAFETY AND HEALTH REGULATIONS" OF T.S.HE UDEPARTMENT OF
LABOR, AND WITH THE ST,,TE OF CALIFORNiA DEPARTMENT OF I'DUSTRIAL RELATIONS' "CONSTRUCTION
SAFETY ORDERS".
THE CIVIL ENGINEER SHALL NOT BE RESPONSIBLE IN ANY WAY FOR THE CONTRACTORS' AND
SUBCONTRACTORS' COMPLIANCE WITH THE "OCCUPATIONAL SAFETY AND HEALTH REGULATIONS" OF
THE U.S. DEPARTMENT OF LABOR OR WITH THE STATE OF CALIFORNIA DEPARTMENT OF INDUSTRIAI
RELATIONS' "CONSTRUCTION SAFETY ORDERS".
CONTRACTOR FURTHER AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILI T `" FOR
I°`'B SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUD! IC" SAFETY
OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT
BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY
AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR
ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR ANY
LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR ENGINEER.
EL PC IL-0,(DIDO1
CALTRANS P� RMI T NO: ; ; _-18-6-DD-0463
CITY OF �Y - - , l -
DRAWN BY: TITLE SHEET SCALE:
R.P. AS SHOWN
DE; IGN1 D BY: POPLAR TORM DRAIN DATE:
D.W. 10/2018
CHECKED BY: s APP VED L! DWG. NO.:
J.M. III'!i T-,0 57A �
1 C1 ENGINEER R.C.E. 51152 DATE: I � l i/ 3