HomeMy WebLinkAbout5741-3CURTIS AVENUE
AREA MAPPED 7N
• qF
CURTIS AVENUE
AREA MAPPED
NO SCALE
3/4" DOMESTIC WATER METER (BY OTHERS) / P.O.C, "5'
I" R.P. 5ACKFLOW, I'M VALVE 4 V PLOW SENSOR
ASSUMED STATIC PRESSURE &0-65 PSI
MAX. DEMAND: 11.0 Cx.PM. / MIN. DEMANID:5.0 GzPM
ELECTRICAL POINT OF CONNECTION "5" - 6 STATION
PEDESTAL CONTROLLER FOR C.F.D. IRRIGATION,
DEVELOPER SHALL PROVIDE 110-120 VAC ELECTRIC
TO THIS LOCATION.
TUBULAR'
EL DENCE
B3
1"
LOT "E"
WQMP BASIN
ROCK BOTTOM
I
i
0
0
L7
NOTRE DAME STREET
TUBULAR
STEELOENCE
43
CITY OF FONTANA NOTE:
AT THE TIME OF FINAL INSPECTION, THE PERMIT APPLICANT MUST
PROVIDE THE OWNER OF THE PROPERTY WITH A CERTIFICATE OF
COMPLETION, CERTIFICATE OF INSTALLATION, AND AN IRRIGATION
SCHEDULE OF LANDSCAPE AND MAINTENANCE
CITY OF FONTANA NOTE:
ALL IRRIGATION SYSTEM DESIGNS THAT WILL BE MAINTAINED BY
THE CITY OF FONTANA SHALL BE INSTALLED AS A RECYCLED
WATER IRRIGATION SYSTEM FOR THE CURRENT AND FUTURE USE
OF RECYCLED WATER AND SHALL BE DESIGNED AND OPERATED IN
ACCORDANCE WITH ALL APPLICABLE LOCAL AND STATE LAWS.
CITY OF FONTANA NOTE: IRRIGATION CROSSINGS
IRRIGATION CROSSINGS UNDER ANY HARD SURFACE
SHALL BE MARKED WITH AN "IR" STENCIL ON WET
CONCRETE ON BOTHE SIDES OF THE STREET/CROSSING
CITY OF FONTANA NOTE: DRIP INDICATORS
CONTRACTOR SHALL INSTALL TWO (2) RAIN BIRD DRIP
INDICATORS PER VALVE. ONE AFTER THE VALVE AND
ONE AT THE END OF THE MANIFOLD SYSTEM. RAIN
BIRD INDICATIOR MODEL #OPERID ITEM #X17500.
CITY OF FONTANA NOTE: PRESSURE REGULATION
PRESSURE REGULATORS SHALL BE INSTALLED ON THE
IRRIGATION SYSTEM ENSURING THAT DYNAMIC
PRESSURE OF THE SYSTEM IS WITHIN THE.
MANUFACTURER'S RECOMMENDED PRESSURE RANGE.
RRIGATION LEGEND
I►
TORO SENTINAL CONTROLLER w/WIRELESS BOARD. MODEL #SBYPSS5U (8 OR 24 STATION) SEE PLAN—MOUNTED 5005,5006/L-6
IN AN APPROVED STAINLESS STEEL NEMA RATED EDISON BOX ENCLOSURE, REFER TO DETAILS FOR ALL CITY
REQUIREMENTS AND ACCESORIES. CONTACT DARYL GREEN AT GREEN PRODUCT SALES WHEN ORDERING
AND TO SCHEDULE INSPECTION FOR CERTIFICATION. (949) 584-7311. GPS100EARTHLINK.NET.
(INSTALL SENTINAL ANTENNA ON THE TOP OF THE RAIN BUCKET POLE AND ELIMINATE RAIN BUCKET.)
HAND HELD IRRIGATION RADIO CONTROLLER SHALL BE FULLY FUNCTIONAL AND TURNED OVER TO THE CITY OF
FONTANA AT THE TIME OF FINAL ACCEPTANCE.
RDOMESTIC WATER METER PER FONTANA WATER (EXISTING). SIZES NOTED.
— — — — — — — PRESSURE MAINLINE PIPING. USE PVC SCH. 40 / BURY MINIMUM 18" DEEP. SIZES NOTED.
NON -PRESSURE LATERAL LINE PIPING -USE SCH. 40 PVC. BURY MINIMUM 12" DEEP.
:..........::: SCH. 40 PVC IRRIGATION SLEEVE UNDER PAVEMENT / SIZE 2 X PIPE OR WIRE BUNDLE
CONTROLLER STATION
VALVE SIZE
FLOW IN G.P.M.
HYDROZONE
AREA (SQ. FT.)
HYDROZONE LEGEND
RAIN BIRD MODEL NO. XFS DRIPLINE. BURIED 4" DEEP BELOW GRADE (.6 GPH 0 18"). INSTALL IN ROWS
D -HA -8
HYDROZONE 01
18"-24" ON CENTER, DEPENDING UPON PLANT MATERIAL SPACING. START 2" AWAY FROM HARDSCAPE.
5HRU55 4 TREES / DRIP
r e
INSTALL WITH ALL RAIN BIRD. COMPRESSION FITTINGS AND COMPONENTS. INSTALL FLUSH VALVES AND AIR
LOW
SHRUBS 4 TREES / DRIP
RELIEF VALVE FOR EACH SYSTEM -TYPICAL. REFER TO RAIN BIRD DETAILS.
HYDROZONE 03
MEDIUM -LOW
RAIN BIRD XFCV DRIPLINE W/ BUILT-IN CHECK VALVE. INSTALL ON GRADE FOR SLOPES. (.6 GPH 0 24")
B/L -7
MODEL #XFCV-06-24-100. INSTALL IN ROWS 24" ON CENTER, START 2" AWAY FROM HARDSCAPE.
51
INSTALL WITH RAIN BIRD XF INSERT FITTINGS AND COMPONENTS. INSTALL FLUSH VALVES AND AIR RELIEF FOR
SYSTEM -TYPICAL. SECURE DRIPLINE TO GRADE WITH RAIN BIRD TDS-050 BEND GALV. STAKES.
LEACH
L�
(MIN. 6' ON CENTER SPACING). REFER TO RAIN BIRD DETAILS ON SHEET L-7.
0
RAIN BIRD XFCV DOUBLE DRIPLINE TREE RING
CA -7
•
DEEP WATERING TREE BUBBLERS: RAIN BIRD RWS-M-B-1402 (0.5 GPM) /2 PER TREE EQUALLY SPACED
AA -7
O
REDUCED PRESSURE BA KFLOW PREVENT�R- WILKINS x/375 (PLASTIC) WITH WILKINS X600 XL-HLR-G.
5007/L-6
(SAME SIZE AS MAINLINE. INSTALL IN A GUARDSHACK" LOCKING - HINDGED ENCLOSURE (GREEN).
UW
RAIN BIRD PRESSURE REDUCING MASTER VALVE - LINE SIZE. SET DISCHARGE PRESSURE
5010 L-6
/
f�p>ESB-R-PRSD
PRESSURE PS REQUIRED. VERIFY EXISTING PRESSURE BEFORE INSTALLING.
®
DATA INDUSTRIAL FLOW SENSOR MODEL #228PV3005 - INSTALL SAME SIZE AS MAINLINE.
5010/L-6
FERTILIZER INJECTOR MODEL #EZ003-CX. LINE SIZE. INSTALL PER MANUFACTURER'S & CITY
XA-7
SPECFOW
►�
NIBCO T-580 BRASS BALL VALVE OR EQUAL- LINE SIZE. INSTALL IN ROUND BOX.
5019/L-6
Q
3/4" RAINBIRD #33DLRC QUICK COUPLING VALVE w/RUBBER COVER IN BOX MARKED "QC"
5021/L-9
RAIN BIRD IN-LINE DRIP ZONE KIT #XCZ-100-PRB-COM FOR FLOWS 0.3-20 GPM. INSTALL IN RECT. BOX
5038/L-9
RAIN BIRD GB BRASS ELECTRIC CONTROL VALVE. INSTALL IN RECTANGULAR BOX. SIZES NOTED.
5011A-6
I►
TORO SENTINAL CONTROLLER w/WIRELESS BOARD. MODEL #SBYPSS5U (8 OR 24 STATION) SEE PLAN—MOUNTED 5005,5006/L-6
IN AN APPROVED STAINLESS STEEL NEMA RATED EDISON BOX ENCLOSURE, REFER TO DETAILS FOR ALL CITY
REQUIREMENTS AND ACCESORIES. CONTACT DARYL GREEN AT GREEN PRODUCT SALES WHEN ORDERING
AND TO SCHEDULE INSPECTION FOR CERTIFICATION. (949) 584-7311. GPS100EARTHLINK.NET.
(INSTALL SENTINAL ANTENNA ON THE TOP OF THE RAIN BUCKET POLE AND ELIMINATE RAIN BUCKET.)
HAND HELD IRRIGATION RADIO CONTROLLER SHALL BE FULLY FUNCTIONAL AND TURNED OVER TO THE CITY OF
FONTANA AT THE TIME OF FINAL ACCEPTANCE.
RDOMESTIC WATER METER PER FONTANA WATER (EXISTING). SIZES NOTED.
— — — — — — — PRESSURE MAINLINE PIPING. USE PVC SCH. 40 / BURY MINIMUM 18" DEEP. SIZES NOTED.
NON -PRESSURE LATERAL LINE PIPING -USE SCH. 40 PVC. BURY MINIMUM 12" DEEP.
:..........::: SCH. 40 PVC IRRIGATION SLEEVE UNDER PAVEMENT / SIZE 2 X PIPE OR WIRE BUNDLE
CONTROLLER STATION
VALVE SIZE
FLOW IN G.P.M.
HYDROZONE
AREA (SQ. FT.)
HYDROZONE LEGEND
ZONE NO./DESCRIPTION
WUCOLS
HYDROZONE 01
LOW -MEDIUM
5HRU55 4 TREES / DRIP
HYDROZONE 02
LOW
SHRUBS 4 TREES / DRIP
HYDROZONE 03
MEDIUM -LOW
TREES / 5U55LER5
REFER TO IRRIGATION NOTES ON SHEET L-2
U
5016A-6
5016/L-6
501 BA -6
j
FRANK REF. REDISION DESCRIPTION DATE ENoR. CITY DATE BASIS OF BEARINGS:
CITY O❑ ❑ONTANA, CALI❑ORNIA
D (� O NNDSCAPf SGOULD CONSTRUCTION OG TLE REQUIRED AKEN FROM THE CENTERLINE OF
�� !���� RADMACHER C� R .�gPcy IMPROGEMENTSNOTCOMMENCEGITOINTGO CITRUS AVENUE AS SHOWN ON TRACT 16540, M.B. 299/13-15. IRRI❑ATION PLAN
�i 4a' %% BEING: N00°16'44"W
ASSOCIATES INC. YEARS OO TLE DATE OCAPPRODAL SGO❑ N
DRA❑ N BY: SCALE:
Signature GEREON AND CARRIED LOORTO IN A DILIGENT BENCHMARK:
5/31/20 LI CITRUS 105 1"mor
Renewal Date * MANNER, TGE CITY ENGINEER MAY REQUIRE K N0. 8-17 DATE:
DIAL Two WORKING TR. 18981 FONTANA, CALIFORNIA
cn BEFORE DAYS BEFORE Landscape APCI11i0CiS s 3/03/1 e Q BRASS CAP IN CONCRETE S.C.E. TOWER LEG. 343' N/0
YOU DIG YOU DIG Date REDISIONS TO TGE PLANS TO BRINE] TOEM INTO 8122018
TOLL FREE 1-800-227-2e00 PHONE (714) 832-1.774 FAX (714) 832-5721. '9T 0� HIGHLAND AVENUE, S.C.E.W/ E SAN SE2.65 ROAD, IN SOUTH
(,Iy A PUBLIC SERVICE BY 14841 Yorba Street, Suite 204 Tustin, CA 92780 F OF C p`\FD CON GORMANCE ❑ITE] CONDITIONS AND CONCRETE BASE OF .C.. TOWER 19.5; 2.65 MI. WEST cneCKED Bv: gppRo�ED BY: DRAT wr No.: 3
(Sa UNDERGROUND SERVICE ALERT @ STANDARDS IN EODECT. ALONG HIGHLAND AVENUE FROM SIERRA AVENUE S ��) �_3
EMAIL: FRA1110 FRAINC.NET EL=1428.609 l FFR R C AAT— 1 3 14